Вы находитесь на странице: 1из 1

Automation of the alignment process of a

solid state laser resonator


C. Brecher1, N. Pyschny1, V. Guerrero1
1. Fraunhofer-Institute for Production Technologies IPT, Steinbachstraße 17, 52074 Aachen, Germany

Resonator alignment is the most challenging step in the manufacturing of solid state lasers. Reduced
dimensions and the high precision needed for achieving high output power efficiency make this procedure
complicated to automate. A completely automated alignment of the resonator would significantly reduce costs
and manufacturing time.
The resonator of a new Micro-slab solid state laser with a design for an automated assembly was successfully
aligned with a new micromanipulator in a flexible automated cell [1]. The developed procedure consists in two
consecutive steps; a passive and an active [2].
Passive alignment, which is based only on the geometry of the system, is performed by optically amplifying
the misalignment of the mirrors. This is done with the help of a low power reference laser which is reflected by
the resonator mirrors to a screen; there the misalignment can be calculated in reference to the orientation of the
front face of the laser crystal. Using a camera and image processing methods, this method was successfully
incorporated in the system. Both mirrors conforming the Long-Radius Hemispherical resonator are first aligned
by this method to after that perform the active alignment, manipulating only one of the mirrors.
The active alignment consists of sampling the output power at different mirror orientations. First, power
samples are obtained following an “X” path to get the approximated orientation for the maximum output power.
From this maximum, the algorithm searches for a higher output power around the previous maximum. This way,
the number of power samples is dramatically reduced; hence, saving a considerable amount of time. In Fig.1, it
is shown the power distribution for different resonator misalignments (a) and the results of one active alignment
scan (b).

Fig.1 (a) Output power for different resonator misalignments, (b) Result of one “X” scanning strategy test.

The passive alignment method already described achieves a parallelism of approximately ± 40 mdeg,
providing an appropriate starting point for the active alignment.
Regarding the active alignment, each complete “X” scan takes about 1 to 2 min using a fast response power
meter (response time < 1 second). The “X” scan is repeated as many times as needed reducing the step size each
time until the desired parallelism is achieved. For this particular laser the “X” scan is repeated four times, using
an step size of 0.5 mdeg in the last scan. Hence, the active alignment takes between 4 and 8 min.
The transfer of the already acquired knowledge to an industrial application could have a positive impact on
manufacturing time and cost, as well as on the laser quality.
More details about the reference and measurement setup, as well as the alignment algorithms, the flexible
assembly cell and the key automation components will be presented.

References
[1] Schmitt, R.; Pavim, A.; Brecher, C.; Pyschny, N.; Loosen, P.; Funck, M.; Dolkemeyer, J.; Morasch, V., “Flexible automated assembly of
solid-state lasers,” wt-online 11/12-2008, 955 (2008).
[2] Mathias Mohaupt, Erik Beckert, Ramona Eberhardt and Andreas Tünnermann, “Alignment procedures for Micro-optics,“ [book auth.]
Svetan Ratcher. Precision assembly technologies and systems, (Springer, Chamonix, 2010).

Вам также может понравиться