Вы находитесь на странице: 1из 1

PUMP DESIGN DATA DESIGN CURVE DATA Design TDH/Power vs.

Capacity
FLOW TOTAL PUMP SHAFT
Design Parameter Units Value CAP DEV HEAD EFF POWER 1400 900 100
Rated Speed RPM 3575 GPM ft % HP(US)
Rated Flow GPM 640 0 1275 0 300 800 90
Total Developed Head @ Rated Flow ft 1170 225 1270 41 420 1200
NPSH Required @ Rated Flow ft 22 449 1250 61 540 80
700
Pump Efficiency @ Rated Flow % 72 674 1190 71 660
Shaft Power HP(US) 642 899 1070 75 770 1000
70
1,124 860 69 825 600
MOTOR DESIGN DATA

Shaft Power (HP(US))


1,348 530 47 850 60
800

Total Head (ft)

Efficiency (%)
500
Design Parameter Units Value 50
Power HP(US) 700 400
600
Voltage Volts AC 2300 40
Rated Speed RPM 3575
300
Motor Efficiency % 93 30
400
Motor Power Factor 0.9
200
20
200
100 10

0 0
0 500 1,000 1,500

Capacity (GPM)