Вы находитесь на странице: 1из 6

CONTENTS

List of alarms

Reliance RJIL 1
NEC Confidential
Alarm list ODU

Alarm Name Category Severity Corrective Action Fault Category

ODU Alarm Alarm MJ Replace Faulty ODU at Local (Alarm) end ODU

Check ODU installed Model & replace with compatible


Type Mismatch Alarm MJ radio model ODU

TX Power Alarm MJ Replace Faulty ODU at Local (Alarm) end ODU

Check IF cable length. Maximum permissible length for


TX Input Alarm MJ 5DFBE is 150 mts. IF cable

Check if ODU Tx power at Opposite end, If yes replace ODU


at near end. Also check is link is misaligned or water ingress
RX Level Alarm in OMT/Antenna at both ned ODU

ODU CPU / Cable Open Alarm MJ Replace IF cable or redo connectorization IF cable

Reliance RJIL 2
NEC Confidential
Alarm list MODEM

Alarm Name Category Severity Corrective Action Fault Category


ODU Power Supply Alarm MN Modem Faulty. Reconnect using 2nd Modem else replace MDU MDU
LOF Alarm MJ Check RSL / Connectorization / Interference in link RF Link

Frame ID Alarm MJ Frame ID in Near end & Far end not the same. Make it same at both end Configuration
High BER Alarm MJ Check RSL / Connectorization / Interference in link RF Link
Low BER Alarm MN Check RSL / Connectorization / Interference in link RF Link
Early warning Alarm Warning Check RSL / Connectorization / Interference in link RF Link
IF Cable Short Alarm MJ IF cable faulty. Repace or redo connectorization IF Cable
MDU Faulty. Replace with good MDU, Connectorisation issue, check CNR MDU/
L2SYNC Loss Alarm MJ setting for AMR Connector
Modem may be faulty. Confirm the same via IF loopback. If no errors in
PMON for 15 min time interval on that Modem then Modem not faulty,
MOD Alarm MJ else faulty MDU
RDI Alarm Warning Indicate an fault at the far end Opposite Site
Unlocked Alarm MJ The Timing source is no more available hence clock unlocked. RF Link

AMR Range Mismatch Alarm MJ Indicates mismatch in AMR setting in local modem and opposite modem Configuration
Header compression setting of local and opposite modems are not the
Compression Setting mismatch Alarm MJ same Configuration
Communication Fail Alarm MJ MDU Faulty. Replace with good MDU MDU
Modem may be faulty. Confirm the same via IF loopback. If no errors in
PMON for 15 min time interval on that Modem then Modem not faulty,
Module Alarm MN else faulty MDU
TX Bus Error Alarm MJ MDU Faulty. Replace with good MDU MDU
RX BUS Error Alarm MJ MDU Faulty. Replace with good MDU MDU
Radio Traffic Aggregation Setting Mismatch Alarm MJ Local and opposite side Traffic aggregation setting not the same Configuration
Login to MDU & go to Modem Maintenance Control. Go to XPIC Reset & Configuration /
XIF Alarm MJ set Forced Reset. If problem solved else replace MDU MDU
CLK Fail Alarm MJ Reference Clock failed (when modem is selected as timing source) RF Link

Reliance RJIL 3
NEC Confidential
Alarm IDU

Alarm Name Category Severity Corrective Action Fault Category

ETH OAM LOC Alarm MJ RF failure in ring topology detected. Ethernet Ring Protection to act RF Link
ETH OAM Mismerge Alarm MN MEG /MEP duplication in ERPS setting Configuration
ETH OAM RDI Alarm MN Receive Ether OAM RDI (Remote Defect Indication) RF Link
Ether OAM Unexpected MEP and Ether OAM Unexpected Period have
ETH OAM Unexpected MEP Alarm MN been detected Configuration
Communication Fail Alarm MJ MDU Faulty. Replace with good MDU MDU

LTI Alarm MJ Loss of timing information from all reference source detected Input Timing Source

CLK Drift Alarm MN Selected Reference Clock Source Frequency drift detected MDU
SSM Fail Alarm MN Check timing Source MDU
MDU CPU alarm Alarm MN MDU Faulty. Replace with good MDU MDU
memory Fail Alarm MJ MDU Faulty. Replace with good MDU MDU
Temperature Alarm MJ The Temperature exceed the threshold Temperature
BUS Error Alarm MJ MDU Faulty. Replace with good MDU MDU
Radio Traffic Aggregation Link Alarm MJ When Modem 1 and Modem 2 radio link fails MDU
Unable to update the License key as mismatch in license file being
License Mismatch Alarm MN updated via to Sr. no. of equipment being upgraded Configuration

Reliance RJIL 4
NEC Confidential
Alarm list GbE

Alarm Name Category Severity Corrective Action Fault Category


Reference Clock failed (when GBE interface is selected as a
CLK Fail Alarm MN clock timing source) Input Timing Source
Loss of Signal detected at the indicated Ethernet Port Optical Cable or
ETH LOS Alarm MJ (Optical).Check Tx or Optical Patch cord Router TX
ETH TF (Transmit Failure) Alarm MJ Replace GBE Interface / MDU SFP or MDU
TX BUS Error Alarm MJ GBE Interface faulty SFP or MDU
RX BUS Error Alarm MJ GBE Interface faulty SFP or MDU
SFP removed Alarm MJ Indicate that the SFP is not plugged in SPF

SFP Type Mismatch Alarm MJ Mounted SFP and the registered information does not match SPFP
Remote Dying Gasp Alarm Mj Remote site equipment is in reboot process Opp Site down
Remote Link Fault Alarm Mj Link failure has been detected at the opposite site Opp Site down

Reliance RJIL 5
NEC Confidential
END of Presentation

NEC Confidential Reliance RJIL 6