Innovators - Developers - Manufacturers Passive Fire Prevention Products
An intumescent grille unit available in two types: wall mounted Can also be supplied with
and glass mounted. smoke shutters with 24V
electro-magnet with automatic
re-set solenoid, or fitted with a
Fan cover units can be installed over VentAxia, Xpelair, or memory spring which closes
other makes of wall or window fans, giving fire and smoke at 60/70℃. Fan cover required
protection to escape corridors and staircase fire escapes. under Building Regulations and
17th Edition of IEE Regulations
PERFORMANCE
Contains a front MG grille, giving up to 73 minutes integrity to
BS476 Parts 20 & 22 (1987). Also tested at VNE to European
Standard EN1363-1 (2000).
ORDERING REFERENCES
FCW Wall-mounted
FCG Glass-mounted
Add suffix /X for Xpelair plus the model, catalogue number, and fan size
Add suffix /V for VentAxia plus the model, catalogue number, and fan size
State other makes.
When ordering fan covers, please allow a minimum 25mm clear gap around the fan mouldings
for ease of fixing and wiring.
For 24 Volt or memory spring phone Technical Department
Integrity Control Systems Ltd | +44 (0) 1202 660 222
info@integritycs.co.uk | www.integritycs.co.uk
Products 33 CLVM Clipper (FOR TOILET VENTILATION FIRE PROTECTION)
PERFORMANCE
Tested to BS476 Parts 20/21/22 (1987).
BS-EN 1363-3 90 minutes fire protection
FITTING INSTRUCTIONS
Take unit and push into Fasten in position with supplied pins,
Slide the PVC or Flexible PVC pipe down the unit.
prepared hole in ceiling/wall. 2 to side and 2 in the bottom holes.
ORDERING REFERENCES
CLVM/110 For 110mm pipes CLVM/150 For 150mm pipes
(Cut-out size 110mm) (Cut-out size 150mm)
All clippers are 140mm high
Unprotected extractor fans connected to ventilation Building Regulations is vital if a potential disaster
ducting are an easy route for the spread of fire and is to be avoided. When fire strikes, the integrity of
smoke within a building. the ceiling could be compromised if an
Firoblok sleeves combat this deadly threat by unprotected fitting is used. Firoblok sleeves are
halting the spread of fire. With increased use of slim Intumescent fire seals that rapidly expand
electrical ventilation fans and ducting in between the ceiling and the pipe or fitting to seal
ceilings of both domestic and commercial the hole and thus form a formidable fire and smoke
buildings, full fire protection a nd c ompliance with barrier.
current fire regulations a nd D ocument B o f UK
Integrity Control Systems Ltd | +44 (0) 1202 660 222 info@integritycs.co.uk | www.integritycs.co.uk
ENVIROGRAF®
Product 34 Automatic Vent Grilles
Integrity Control Systems Ltd | +44 (0) 1202 660 222
info@integritycs.co.uk | www.integritycs.co.uk
1 2 3 4
HOLE HEIGHT
HOLE WIDTH
5 6 7 8
290 xto
cut out to
430mm
390 x 505mm
580mmreset; you
closed (this
as in picture
450is the section that fits into465
x 490mm
450 x 565mm
350 x3). Pictures 4 & 5 show the
640mm
into the aperture and screwed to the wall, door or
the opening,
558
624 grille fitted
NTJ grilles are for use in areas where both fire and smoke protection are required. There are four types of TJ grilles:
the slots
A and make
A TJ grille wired against
into a 24Vthe fire magnet.
alarm system Type
that isNTJ - by
held open partition.
a 24V 125mA The picture This
electromagnet. alsotype shows
will closethewhenslot where
the supply is
the intumescent and smoke shutter closed. Type NTJ - Memory Spring.
supply D to the grille is made, the solenoid pulls the in ventilation ducting. The plates
The NTJ grille can be fitted into doors, walls and partitions. Cut a hole in the door or wall to the sizes as quoted in the chart above, as are open slotted
grille shown
open, then 1.switches
in picture Other sizes can off,be letting
made to suit theyour magnet as the
opening. Pictures opposite
1 & 2 show vents open side, picture
and closed (this 7. Should
is the you
section that not
fits into
the opening, as in picture 3). Pictures 4 & 5 show the grille fitted into the aperture and screwed to the wall, door or partition. The picture also
take shows
over.the Type NTJ - Automatic. require seeing
clot where a key can be pushed into the open vents or non-automatic NTJ grille (magnet only grille).
through the grille, picture 8 shows a
C Picture The same
6 shows
HOLE WIDTH
theNTJ
insidecan be
and outside made with
of the intumescent a supply
plate which islouvred
screwed tononviewing
the opposite side intumescent
of the door, wall face-plate
or partition, thancan be
the main
to a unit.
fire This
alarm system.
unit need The ifsmoke
not be fitted the main unitshutter
is fittedisin held
ventilation supplied.
ducting.
The plates are open slotted as the opposite side, picture 7. Should you not require seeing through the grille, picture 8 shows a louvred non-
openviewing
by a intumescent
thermal link, which,
face-plate can beonce 55°C reaches
supplied. Other Options: If you have no fire alarm, no smoke
the
5 grille, the link
Other Options: If youbreaks,
have no fire shutting
6alarm, nothe smoke smoke
detectorandcircuit, ordetector circuit,
7 load capacity,
no a 240Vortono 24Vload capacity,
unit can8 be supplied. a 240V
This alsotohas24Va
circuit to a smoke detector and a pair or normally open or normally closed contacts, to contact to the existing fire alarm em.
syst
intumescent shutter. Type NTJ - Thermal Link. The unit can be supplied. This also has a circuit to a
same NTJ grille, but this grill has a memory spring, smoke detector and a pair of normally open or
which once a heat of 50-55°C reaches the grille, the normally closed contacts, to connect to the existing
memory spring expands, pushing thePROTECTING intumescentPROPERTY fire alarm system.
and smoke shutter closed. Type NTJ PROTECTING - Memory LIVES
Spring.
COPYRIGHT © 2005INTUMESCENT SYSTEM
S LTD
Intumescent Systems Ltd, Envirograf House, Barfrestone, Dover, Kent, CT15 7JG, United Kingdom
ORDERING
Phone: +44 (0) 1 304 842 555 –INTERNAL HOLE
Fax: +44 (0) EXTERNAL SIZE– URL: www.envirograf.com
1304 842 666 – Email: sales@envirograf.com VENT AREA
REFERENCES HEIGHT x WIDTH HEIGHT x WIDTH (cm²)
NTJ1 140 x 280mm 200 x 340mm 090
NTJ2 240 X 280mm 300 x 340mm 111
NTJ3 190 x 305mm 250 x 365mm 124
NTJ4 270 x 305mm 325 x 365mm 186
NTJ5 340 x 380mm 400 x 440mm 347
NTJ6 390 x 430mm 450 x 490mm 465
NTJ7 390 x 505mm 450 x 565mm 558
NTJ8 290 x 580mm 350 x 640mm 624
NTJ grilles are for use in areas where both fire and smoke protection are required. There are four types of TJ grilles:
ENVIROGRAF®
FIRE PREVENTION PRODUCTS
Product 35 Intumescent MG & MGL Grilles
TECHNICAL INFORMATION AND APPLICATION INSTRUCTIONS
Tested up to 71 minutes Integrity & 54 minutes Insulation
INTUMESCENT MG & MGL GRILLES
Envirograf® Product 35 – Tested up to 71 minutes Integrity & 54 minutes Insulation
These intumescent slotted (MG) or louvred (MGL) the risk side and one plain front plate on the other
MG give
grilles (SLOTTED)
from GRILLE SHOWING
30 minutes to 71 minutesENVIROGRAF®
integrityPRODUCTside 35 GRILLES
(order referenceMGL MG/S(LOUVRED) GRILLE or
for slotted SHOWING
MGL/S
INTUMESCENT STRIPS
in a fire. The grilles are made from 20SWG metal AVAILABLE IN A RANGE OF FINISHES INTUMESCENT
for louvred). For ceilings, ducting, etc requiring one STRIPS
and consist of a front plate with slots (MG) or louvres hour of fire protection, use MG/S (slotted) or MGL/S
These
(MGL)intumescent
and a slotted slotted (MG)plate
back or louvred
which(MGL)holdsgrilles
the give from 30Screws
(louvred). minutesare to supplied
71 minutes to integrity in a fire.
fix the grilles The
to the
grilles are made from 20SWG
protective intumescent material. The metal and consist of a
door etc. front plate with slots (MG) or louvres (MGL) and a slotted back
plate
front which
plate holds
can be thefinished
protective
in Envirograf®
black, brown, intumescent
white, material.
There are Thenofront
known plate can be
health finishedassociated
hazards in black, brown,
with
white, stainless steel, or polished brass, and BS/RAL colours can be made to order. It has 5mm returns into which the
stainless steel, or polished brass, and BS/RAL this product. In a fire, the intumescent material will
intumescent back plate is located.
colours can be made to order. It has 5mm returns expand to fill the openings in approximately 48
For
into60 minutes
which the protection
intumescent on aback
doorplate
or wall, two grilles would
is located. be required
seconds. No smoke(one each side) as
or toxic it is not
fumes are certain
emitted which
by
side the fire will attack from (order reference
For 60 minutes protection on a door or wall, two MG/D for slotted or MGL/D for louvred). For 30/60 minutes
this product. If this product is to be used in operating protection on
the risk side only (the room side of a door or
grilles would be required (one each side) as it is not wall) use one grille on the risk side and one plain front
theatres or other sterile or food preparation areas, plate on the other
side (order reference MG/S for slotted
certain which side the fire will attack from (orderor MGL/S for louvred).
the For ceilings, ducting,
intumescent material etc inrequiring one hour
the grilles canof befire
protection, use MG/S (slotted) or MGL/S
reference MG/D for slotted or MGL/D for louvred).
(louvred). Screws are supplied to fix the grilles to the door
supplied fully sealed. See overleaf for illustrated
etc.
There are nominutes
For 30/60 known health hazards
protection onassociated
the risk sidewith only
this product.
details In aoffire,
MG theandintumescent
MGL grille material
sets,willwith
expand to fill
fixing/
the openings in approximately 48 seconds.
(the room side of a door or wall) use one grille on No smoke or toxic fumes are emitted
application examples. by this product. If this product is to
be used in operating theatres or other sterile or food preparation areas, the intumescent material in the grilles can be
supplied fully sealed. See overleaf for illustrated details of MG and MGL grille sets, with fixing/application examples.
SLOTTED / EXTERNAL SIZE HOLE SIZE NUMBER OF SLOTTED AREA LOUVRED AREA
LOUVRED* H x W (mm) H x W (mm) VENT HOLES MG (cm²) MGL (cm²)
MG1/MGL1 150 x 200 100 x 150 10 58 27
MG2/MGL2 200 x 200 150 x 150 14 81 38
MG3/MGL3 275 x 200 225 x 150 22 127 60
MG3A/MGL3A 200 x 275 150 x 225 24 139 66
MG4/MGL4 275 x 275 225 x 225 30 174 82
MG4A/MGL4A 300 x 300 250 x 250 33 191 91
MG5/MGL5 350 x 350 300 x 300 52 301 143
MG6/MGL6 350 x 425 300 x 375 75 434 206
MG7/MGL7 425 x 350 375 x 300 68 393 187
MG8/MGL8 425 x 425 375 X 375 90 521 247
MG8A/MGL8A 350 x 500 300 X 450 84 486 230
MG9/MGL9 500 x 500 450 x 450 126 729 346
MG10/MGL10 650 x 650 600 x 600 216 1250 592
MG11/MGL11 550 x 550 500 x 500 132 764 362
*To the references shown, please add /S for single risk side applications (one intumescent grille and one plain front plate supplied) or
add /D for double risk side applications (two intumescent grilles supplied). Other sizes can be made to order
Integrity
Phone: +44 (0) 1 304 842 555 – Fax: +44 Control
(0) 1 304 Systems
842 666 – Email:Ltd | +44 (0) 1202 660
sales@envirograf.com 222 www.envirograf.com – IS035T-0-2009
– URL:
nfo@integritycs.co.uk | www.integritycs.co.uk
CONSTRUCTION DIAGRAM OF MG AND MGL GRILLE SETS
GRILLE SET FOR SINGLE RISK SIDE (/S) GRILLE SET FOR DOUBLE RISKS (/D)
INTUMESCENT BACK PLATES FIT INSIDE THE RISK SIDE FACE PLATES
INTUMESCENT BACK PLATES FIT INSIDE THE RISK SIDE FACE PLATES
INTUMESCENT BACK PLATE FITS INSIDE THE RISK SIDE FACE PLATE
INTUMESCENT BACK PLATE FITS INSIDE THE RISK SIDE FACE PLATE
RISK SIDE LOUVRED INTUMESCENT GRILLE
AN MG GRILLE BEFORE BEING AN MG GRILLE AFTER BEING MG & MGL GRILLES ARE QUICK
SUBJECTED TO A FIRE TEST SUBJECTED TO A FIRE TEST AND EASY TO FIT
CEILING CEILING
MG OR MGL
NON-RISK DOOR RISK GRILLE RISK DOOR RISK
SIDE SECTION SIDE SIDE SECTION SIDE
GRILLE PROTECTING CEILING VENTILATION
NEW BG-GRILLE
ORIGINAL BG-GRILLE
B
m D
m AR
38 ND
A
A
ST
FIXING FIXING
LUG LUG
BEFORE FIRE
C TEST
FIXING FIXING
LUG LUG
BLOCK GRILLE SHOWING INTUMESCENT BLOCK GRILLE INTUMESCENT BLOCK GRILLE IN A TEST THE GRILLE
ORDERING DIMENSIONS FITTED WITH FIXING LUGS SEALS UP IN APPROXIMATELY ONE MINUTE
PERFORMANCE
This product underwent a fire resistance test
employing the general principles and criteria of
BS476 Part 22 (1987), achieving an integrity of 66
minutes.
ORDERING REFERENCES
USE
For services passing through fire-rated c eilings and
walls (especially where contraction and expansion
allowance is required, e.g. water/gas pipes). Also for
use in brick, block, concrete, and hollow floors or
walls.
PERFORMANCE
This product underwent a fire resistance test
employing the general procedures and criteria of
BS476 Part 22 (1987), achieving an integrity of 130
minutes in solid walls, 67 minutes in hollow walls, and
4 hours in concrete/ block ceilings/walls. Also tested
to EN1366-3 (2005), EN1363-1 (2000), and EN13501-
2 (2004).
The grille can be used on partition walls and doors, to prevent fire
passing from one room to another. To accommodate the grille, the
ventilation aperture must be at least 10mm larger than the height
between the upper and lower opposing slot limits (the slots should be
vertically opposite each other when fitted).
PERFORMANCE
Tested to European Standards and approved in accordance with
the general principles of NEN6069, offering up to 60 minutes of fire
protection plus sound absorption.
The grille can be easily mounted with screws onto a door or wall.
PERFORMANCE
Maximum sound absorption at a minimal air-resistance (20 Pa) is
achieved at an air speed no greater than 1.9m/s, calculated on the
open passage of the grille, with measurement of the sound insulation
according to world standard ISO140-3 (1995).
ORDERING REFERENCES
HMG/1 110mm high x 280mm wide
HMG/2 140mm high x 280mm wide Integrity Control Systems Ltd | +44 (0) 1202 660 222
Add /C or /W when ordering to specify product type. info@integritycs.co.uk | www.integritycs.co.uk
Product 150 New SVG Grille
SVG grille
Remained
intact after test
ORDERING REFERENCES
TO FIT OPENING
SVG900 900mm wide x 75mm high x 60mm deep.
SVG360 360mm wide x 100mm high x 100mm deep.
Other sizes made to order.
Integrity Control Systems Ltd | +44 (0) 1202 660 222
info@integritycs.co.uk | www.integritycs.co.uk
Product 155 Door and Cupboard Ventilation
PATENT PENDING
Every effort has been made to ensure that the information in this document is correct at the time of
publication. However, this publication does not form any part of a contract and Integrity Control Systems
Ltd does not accept responsibility for products that are not used according to instructions, nor for any
other form of non-compliance. Integrity Control Systems Ltd takes no responsibility for errors or
omissions in this publication, nor for changes that occur after publication.
Integrity Control Systems Ltd reserves the right to revise product specifications and published
information at any time without prior notice. No reproduction in whole or in part without permission.
info@integritycs.co.uk www.integritycs.co.uk