Вы находитесь на странице: 1из 13

Jabil Circuit Vietnam

Test Engineering Department

FA Report
Strain Gage Measurement
for depanel AP1230
at In-Line Router machine BAY15

BU/WC : SOLAR EDGE


FA ID : SGS-00000340
Prepared by : Hien Pham
Date : 20-Aug-2020
BACKGROUND & OBJECTIVES

- WC SE needed to do strain gauge measurement as customer required for model AP1230 at In-Line Router machine
BAY15 to ensure no overstress applying on PCB while de-panel.

- 01 panel was sent to FA Lab to attach 5 rosette sensors at checked location (pls refer to 4th slide).

2
FA FINDINGS & SUMMARY

❖Perform Strain Gage Measurement at 5 locations on 1 PCBA during de-paneling.

Reading
(𝝁m/m) Criteria*
Sensor Status
(𝝁m/m)
Max Principal Strain Min Principal Strain
1 58.87 -276.98 <= 200 Fail
2 125.28 -143.27 <= 200 Pass
3 186.09 -119.21 <= 200 Pass
4 145.55 -246.73 <= 200 Fail
5 147.23 -223.15 <= 200 Fail

*Customer’s spec: 200um/m


3
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Attach rosette sensors on PCBA

4
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Place PCBA on Router machine

5
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Strain Gage Result at Rosette Sensor 1

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

E1 -152.56 <= 200 Pass

E2 53.13 <= 200 Pass

E3 -158.60 <= 200 Pass

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

Max-SN1 58.87 <= 200 Pass

Min-SN2 -276.98 <= 200 Fail

6
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Strain Gage Result at Rosette Sensor 2

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

E1 -60.11 <= 200 Pass

E2 -133.85 <= 200 Pass

E3 40.71 <= 200 Pass

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

Max-SN1 125.28 <= 200 Pass

Min-SN2 -143.27 <= 200 Pass

7
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Strain Gage Result at Rosette Sensor 3

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

E1 -64.54 <= 200 Pass

E2 -119.21 <= 200 Pass

E3 -85.36 <= 200 Pass

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

Max-SN1 186.09 <= 200 Pass

Min-SN2 -119.21 <= 200 Pass

8
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Strain Gage Result at Rosette Sensor 4

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

E1 -131.74 <= 200 Pass

E2 -91.72 <= 200 Pass

E3 -218.80 <= 200 Fail

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

Max-SN1 145.55 <= 200 Pass

Min-SN2 -246.73 <= 200 Fail

9
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
Strain Gage Result at Rosette Sensor 5

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

E1 -82.74 <= 200 Pass

E2 77.30 <= 200 Pass

E3 120.33 <= 200 Pass

Measurement Reading
Criteria Status
Channel (Max – 𝝁m/m)

Max-SN1 147.23 <= 200 Pass

Min-SN2 -223.15 <= 200 Fail

10
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
BACKUP

11
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
REFERENCE PROCEDURES

• 50-TE40-INS-015-001 - JFAD System Visual Aids

12
PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.
THANK YOU

PUBLIC | ©Jabil Inc. 2017. All Rights Reserved.