Вы находитесь на странице: 1из 4

25/9/2020 ALM-25952 User Plane Path Fault

ALM-25952 User Plane Path Fault


Network Element: BTS3900, BTS3900 WCDMA, BTS3900 LTE, BTS5900, BTS5900 WCDMA, BTS5900 LTE

Alarm Description

If transmission links are automatically set up and the static detection function is enabled (the X2, eX2, Xw, S1, and F1
interfaces for LTE or the gNBX2, gNBS1, and gNBF1 interfaces for NR support only GTP-U detection and the uX2
interface for UMTS supports only UDP ping detection).
For the LTE X2, eX2, Xw, S1, and F1 interfaces or the NR gNBX2, gNBS1, and gNBF1 interfaces, the system sends
an echo request every minute when link GTP-U static detection is enabled. This alarm is reported when no echo
response is received within the configured echo response timeout duration and the number of timeouts exceeds the
threshold for the number of echo response timeouts. The echo response timeout duration and threshold for the
number of timeouts are configured using the MOD GTPU command, and their default values are 5000 ms and 3,
respectively.
The link GTP-U static detection is considered enabled in the following scenarios:
1. Static Check Mode in the GEPMODELPARA MO is set to EPSTATICCHK(Endpoint Group Static Check) and Static
Check Switch in the EPGROUP MO which the link corresponds to is set to ENABLE(Enable).
2. Static Check Mode in the GEPMODELPARA MO is set to EUPPEERSTATICCHK(User-Plane Peer Static Check)
and Static Check Switch in the USERPLANEPEER MO which the link corresponds to is set to ENABLE(Enable).
3. Static Check Mode in the GEPMODELPARA MO is set to EUPPEERSTATICCHK(User-Plane Peer Static Check),
Static Check Switch in the USERPLANEPEER MO which the link corresponds to is set to FOLLOW_GLOBAL(Same
as the GTP-U static detection switch), and Static Check Switch in the GTPU MO is set to EABLE(Enable).
For the UMTS uX2 interface, the system sends an echo request every 10 seconds if UDP ping static detection is
enabled. This alarm is reported when no echo response is received within the configured echo response timeout
duration and the number of timeouts exceeds the threshold for the number of echo response timeouts. The echo
response timeout duration and threshold for the number of timeouts are configured using the SET UDPPING
command, and their default values are 5000 ms and 3, respectively.

Alarm Attribute

Alarm Parameters

Impact on System

Alarm Severity Alarm Impact


Major User plane services cannot be processed.

System Actions

None.

Possible Causes

Cause Category Possible Causes


Data configuration A route from the local end to the peer end is not configured on the user plane.
The packet filtering function is enabled on the NE, but the corresponding ACL
rule is not configured or is incorrectly configured.

Software None
Hardware The hardware of the board that carries the user plane is faulty.
Miscellaneous The user plane path's underlying bearer link is faulty.
The certificate is invalid.
In the local end, the packet filtering function is enabled, resulting in the user plane
path detection failure.
Network or peer device configuration is incomplete, resulting in the user plane
path detection failure.

Prerequisites

https://10.108.0.102/hedex/hdx.do?fe=1111&lib=OMC&p=h&id=26245&uv=125_BTS3900 WCDMA V100R013C10SPC180_Alarm 1/4


25/9/2020 ALM-25952 User Plane Path Fault

Obtain the product documents and read the following chapters or documents:

Initial Configuration Guide

Before handling this alarm, ensure the following:

You have obtained the reference documentation related to this alarm.

Preprocessing

1. Check whether a correlated alarm is reported

Procedure Items to Be Confirmed Duration Impact


(min.)
Check for the root alarms on the Check whether root alarms are reported on 1 None
U2000. the U2000:
25800 E1/T1 Loss of Y=>The root alarms are reported. Clear these
Signal root alarms.
25801 E1/T1 Alarm N=>The root alarms are not reported.
Indication Signal Continue handling this alarm.
25802 E1/T1 Remote
Alarm Indication Signal
25803 E1/T1 Loss of
Frame Alignment
25804 E1/T1 Loss of
Multiframe Alignment
25805 E1/T1 Excessive
Slip Frames
25806 E1/T1 Excessive
Bit Error Rate
25807 E1/T1 Loopback
25880 Ethernet Link
Fault
25881 MAC Excessive
Frame Error Rate
25887 Ethernet Trunk
Link Fault
25895 Ethernet Trunk
Group Fault
25891 IKE Negotiation
Failure
26832 Peer Certificate
Expiry
26841 Certificate
Invalid
26831 802.1x
Authentication Failure
26842 Automatic
Certificate Update
Failed
25860 PPP/MLPPP
Link Fault
25861 MLPPP Group
Fault
25862 MLPPP Group
Excessive Packet Loss
Rate
25863 PPP Link
Excessive Frame Error
Rate
25884 ETHOAM 3AH
Remote Fault
25885 IP Address
Conflict

https://10.108.0.102/hedex/hdx.do?fe=1111&lib=OMC&p=h&id=26245&uv=125_BTS3900 WCDMA V100R013C10SPC180_Alarm 2/4


25/9/2020 ALM-25952 User Plane Path Fault

Procedure Items to Be Confirmed Duration Impact


(min.)
25894 ETHOAM 3AH
Remote Loopback
25896 IP Remote
Loopback
25899 BFD Session
Fault
26220 Transmission
Optical Module Fault
26221 Transmission
Optical Module Not In
Position
26222 Transmission
Optical Interface Error
26223 Transmission
Optical Interface
Performance Degraded

Configuration Handling

Remote Handling

Expand All

1. Reset the board

a. Display the Main Topology window


b. Confirm the connection status of NE
c. Open the MML Command window
d. Reset the board
e. Check whether the alarm is cleared

2. Collect information

Onsite Preparation

None.

https://10.108.0.102/hedex/hdx.do?fe=1111&lib=OMC&p=h&id=26245&uv=125_BTS3900 WCDMA V100R013C10SPC180_Alarm 3/4


25/9/2020 ALM-25952 User Plane Path Fault

Onsite Handling

None.

Related Information

None.

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd.

https://10.108.0.102/hedex/hdx.do?fe=1111&lib=OMC&p=h&id=26245&uv=125_BTS3900 WCDMA V100R013C10SPC180_Alarm 4/4

Вам также может понравиться