As per Terzaghi & Peck, Pressure distribution can be calculated as:

Here
q = 190 kPa
µ = 0.3
z = 8.9 m
a or r = 3.5 m

Hence
Δσ v = 36.86 kPa Max at the centre of footing

At the crown of Tunnel σz = q(A+B)

Where A & B are calculated from the Table (Ahlvin & Ulery)
A = 0.05974
B = 0.0913

Hence on Tunnel Crown, σz = 28.70 kPa