Вы находитесь на странице: 1из 10

FLODIS DN25 -32

Single Jet Velocity Type Water Meter, Class C

FLODIS
DN 25/32

Service Manual

Itron
11, Boulevard Pasteur
67500 Haguenau - France
Tel. : +33 3 88 90 63 00
Fax. : +33 3 88 73 23 20

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

Flodis
(DN25/32)

Content
Introduction

Dismantling / Re-assembly Guide

Spare-parts List

Testing Guide

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

INTRODUCTION

Flodis is a single-jet velocity meter type. Approved in class C (horizontal position)


according EEC/75/33 directive, it fulfills as well the provisions of ISO 4064/1
standard.

Its low flow performances combined with exceptional endurance capabilities are
achieving to make of Flodis the ideal meter for billing applications.

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

DISMANTLING AND RE-ASSEMBLY GUIDE

Required Tools
Phillips screwdriver no : 3, 4 or 5

Dismantling
Insert the screwdriver between the ear’s of the plastic cap, bend slowly pull out
the removable plastic,
Remove the fitted register,
Unscrew the ring with the anti-fraud ring (with register stop ring for TSN version),
Remove the plate O-ring then the magnet holder,
Remove the upper baffle plate,
Remove the fitted turbine,
Unscrew the lower pivot (counterclockwise direction),
Remove the lower baffle plate,
Remove the filter with a staple.

Re-assembly
Fit lower plate and screw the lower pivot,
Fit the turbine, the upper baffle plate and the magnet holder,
Fit the plate O’ ring,
Fit the pressure plate
Screw the ring with the anti-fraud ring (with register stop ring for TSN version),
Fit the register and the cap, screw the cap and seal the meter.
Fit the filter.

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

SPARE PARTS DN25/32 TSN REGISTER

2 1

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C


Drawing Part designation DN25 DN32 Part number

1 FILTER 1 3835907
1 3835908
2 INLET KIT 1 3336641
1 3336642
3 HYDRAULIC KIT 1 1 3336643

4 PRESSURE PLATE KIT 1 1 3336644

5 REGISTER 1 3835165
1 3835172
6 COVER KIT 1 3336647
1 3336648

VARIANTS:
NRPRINTED REPAIRABLE CAP 1 3835986
1 3835987
NRCLIP FOR REPAIRABLE CAP 1 1 3835432

NRUPGRADE KIT: COPPER CAN 1 3336023


REGISTER io PLASTIC REGISTER 1 3336024
(including register, capping parts,
adaptation ring on pressure plate)

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

SPARE PARTS DN 25/32 TVM REGISTER

10
6

7
4

3
3c

2 1
3a

2b

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C


Drawing Part designation DN25 DN32 Part number

1FILTER 1 3835907
1 3835908
2INLET KIT 1 3336641
1 3336642
3INJECTOR 1 3835573
1 3835423
3HYDRAULIC KIT 1 1 3336643
4PRESSURE PLATE KIT 1 1 3336659
5REGISTER 1 A4000346
1 3836064
6COVER KIT 1 3336645
1 3336646

Itron is bound by the foregoing specifications only after confirmation – 08/08


FLODIS DN25 -32
Single Jet Velocity Type Water Meter, Class C

TESTING GUIDE

Please refer to ISO 4064/3 : Test methods and equipment for a complete testing
guide.

According the provisions of EEC/ISO, the smallest increment on the Flostar M


register (under the format of a graduation in the area of the Cyble pointer) allows to
test the meter in the area of Qmin in a reasonable amount of time (< 1h30mn) with
limited manual read uncertainty (< 0,5%).

Recommended minimum test volumes for manual read :

Qmin to Qt Qt to Qn Qn to Qmax
Flodis DN25 20 liters 500 liters 500 liters
Flodis DN32 20 liters 500 liters 1000 liters

Should you require advises on how to fasten testing time through automatic reading
of stroboscopic disk located inside the register (optical read), please consult us.

Itron is bound by the foregoing specifications only after confirmation – 08/08

Вам также может понравиться