Service Manual
Itron
11, Boulevard Pasteur
67500 Haguenau - France
Tel. : +33 3 88 90 63 00
Fax. : +33 3 88 73 23 20
Flodis
(DN25/32)
Content
Introduction
Spare-parts List
Testing Guide
INTRODUCTION
Its low flow performances combined with exceptional endurance capabilities are
achieving to make of Flodis the ideal meter for billing applications.
Required Tools
Phillips screwdriver no : 3, 4 or 5
Dismantling
Insert the screwdriver between the ear’s of the plastic cap, bend slowly pull out
the removable plastic,
Remove the fitted register,
Unscrew the ring with the anti-fraud ring (with register stop ring for TSN version),
Remove the plate O-ring then the magnet holder,
Remove the upper baffle plate,
Remove the fitted turbine,
Unscrew the lower pivot (counterclockwise direction),
Remove the lower baffle plate,
Remove the filter with a staple.
Re-assembly
Fit lower plate and screw the lower pivot,
Fit the turbine, the upper baffle plate and the magnet holder,
Fit the plate O’ ring,
Fit the pressure plate
Screw the ring with the anti-fraud ring (with register stop ring for TSN version),
Fit the register and the cap, screw the cap and seal the meter.
Fit the filter.
2 1
N°
Drawing Part designation DN25 DN32 Part number
1 FILTER 1 3835907
1 3835908
2 INLET KIT 1 3336641
1 3336642
3 HYDRAULIC KIT 1 1 3336643
5 REGISTER 1 3835165
1 3835172
6 COVER KIT 1 3336647
1 3336648
VARIANTS:
NRPRINTED REPAIRABLE CAP 1 3835986
1 3835987
NRCLIP FOR REPAIRABLE CAP 1 1 3835432
10
6
7
4
3
3c
2 1
3a
2b
N°
Drawing Part designation DN25 DN32 Part number
1FILTER 1 3835907
1 3835908
2INLET KIT 1 3336641
1 3336642
3INJECTOR 1 3835573
1 3835423
3HYDRAULIC KIT 1 1 3336643
4PRESSURE PLATE KIT 1 1 3336659
5REGISTER 1 A4000346
1 3836064
6COVER KIT 1 3336645
1 3336646
TESTING GUIDE
Please refer to ISO 4064/3 : Test methods and equipment for a complete testing
guide.
Qmin to Qt Qt to Qn Qn to Qmax
Flodis DN25 20 liters 500 liters 500 liters
Flodis DN32 20 liters 500 liters 1000 liters
Should you require advises on how to fasten testing time through automatic reading