Академический Документы
Профессиональный Документы
Культура Документы
Product Specifications
1. Software Specifications................................... Spec-1
1.1 Product Code......................................................... Spec-1
1.2 Optional Item Components..................................... Spec-1
1.3 Dimensions/Weight................................................ Spec-2
1.4 Environmental Conditions...................................... Spec-2
1.5 Network Cable........................................................ Spec-2
1.6 Equipment Disposal............................................... Spec-2
2. Hardware Procurement.................................... Spec-3
2.1 Specified Computer Model..................................... Spec-3
2.2 Specified Monitor Model......................................... Spec-4
2.3 Specified Video Card.............................................. Spec-4
Installation (IN)
1. CL Installation Conditions.................................... IN-1 4.3 Creating the FTP Server...........................................IN-23
4.4 Installing MSDE and Its Service Pack.......................IN-24
1.1 Dimensions and Weight..............................................IN-1
4.5 Installing the CL-AP...................................................IN-26
1.2 Temperature and Humidity..........................................IN-1
4.5.1 Installing the CL-AP...........................................................IN-26
1.3 Places of Installation...................................................IN-2
4.5.2 Replacing the Menu Database...........................................IN-29
1.4 Power Requirements...................................................IN-2
4.6 Installing the CL Components...................................IN-32
1.5 Grounding....................................................................IN-2 4.6.1 Built_in Console.................................................................IN-32
1.6 Network Cable.............................................................IN-2 4.6.2 FRIS Modules....................................................................IN-33
2. Installation Workflow............................................ IN-3 4.7 Installing the Standard Key.......................................IN-35
4.8 Installing the Option Key...........................................IN-36
3. CL Hardware Setup............................................... IN-4 4.9 Installing the AP Key.................................................IN-38
3.1 Unloading and Unpacking...........................................IN-4 4.10 Initializing the Image Database.................................IN-39
3.2 Checking the Component Items..................................IN-5 4.11 Display Optimization (LUT file settings)....................IN-41
3.3 Installing the Accessories and Optional Items.............IN-8 4.13 IIS Network Virus Protection.....................................IN-45
3.3.1 Keyboard, Mouse, and Power Cable...................................IN-8 4.14 CL-AP Startup...........................................................IN-46
3.3.2 Monitor.................................................................................IN-9 4.15 Firewall Settings........................................................IN-47
3.4 Confirmation of the BIOS Settings............................IN-10 4.16 Setup for the CL with the Service Utility....................... IN-52
4.16.1 Starting the Service Utility..................................................IN-52
4. CL Software Setup...............................................IN-11 4.16.2 CL System Information Setup............................................IN-52
4.1 Setting the OS.............................................................. IN-11 4.17 Other Settings.............................................................. IN-55
4.1.1 Setting Windows XP........................................................... IN-11
4.1.2 Setting the OS....................................................................IN-16
4.2 Setting Up the Monitor...............................................IN-22
4.2.1 Monitor with Touch Panel...................................................IN-22
4.2.2 Super Resolution LCD Monitor SL-IC300.............................IN-22
4.2.3 LCD Monitor SL-IC200..........................................................IN-22
Product Specifications
l CR IR 348CL Lite
Model Dell Optiplex 760MT
CPU Pentium-Dual Core E2220 (2.4GHz, 1333 MHz FSB)
Main memory 1GB DDR2 SD-RAM
Graphic memory On board
HDD 80GB (S-ATA)
LAN 10/100/1000 BASE-T
Ports USB 2.0, front x 2, rear x 6
Expansion card slots PCI x 2
Drive DVD-ROM Drive, 3.5" FDD
OS Windows XP Professional SP3 (English Version)
Keyboard English keyboard
Display resolution Compatible with 1024 x 768 color touch panel Display 2M monochrome
Specified
Model Nanao FlexScan L362T Specified video Model Matrox M9120 PCIe x 16
monitor 1
Specification 15" touch panel color LCD monitor, 1024 x 768 card 1 Memory 512MB
Display resolution Compatible with 1280 x 1024 color touch panel Connector DVI x 2
Specified
Model Nanao FlexScan L560T Display 3M monochrome/color
monitor 2
Specification 17" touch panel color LCD monitor, 1280 x 1024 Specified video Model Eizo Nanao VREngine/SMD5-PCI
Display resolution 1600 x 1200 (2M monitor), monochrome card 2 Memory 128MB
Specified
Model Nanao RadiForce G22-CL Connector DVI x 2
monitor 3
Specification 19.6" monochrome LCD monitor, 1600 x 1200
Display resolution 2048 x 1536 (3M monitor), color
Specified
Model Nanao RadiForce R31
monitor 4
Specification 20.8" color LCD monitor, 2048 x 1536
Display resolution 2048 x 1536 (3M monitor), monochrome
Specified • Nanao RadiForce GS310-CL
Model
monitor 5 • Nanao RadiForce GS310-CLG
Specification 20.8" monochrome LCD monitor, 2048 x 1536
Installation (IN)
IMPORTANT
4.11 Display Optimization (LUT file settings)
Have on hand a CD-ROM that stores the CL’s AP key, which is distributed for Only when remote
4.12 Setting Up NetMeeting [Reference]
use in servicing. maintenance mode is used.
3.3 Installing the Accessories and Optional Items 4.16 Setup for the CL with the Service Utility
4.2 Setting Up the Monitor For details of the RU master IIP, see “6. RU-CL N:N Conection Function
Overview” under “MD: Machine Description” in the Service Manual of the
4.3 Creating the FTP Server
For RU-CL 1:1 connection : Essential CR-IR 346/348CL.
For RU-CL N:N connection : Only for RU master IIP
uuCAUTIONSuu
When unloading, transferring, and unpacking the machine, observe the
following precautions:
Do not subject the machine to vibration or shock.
If the machine is unduly vibrated or shocked while it is unloaded or
transferred, it may become damaged or defective.
Avoid moisture condensation inside the machine.
If the machine is subjected to a drastic temperature change when it is
transferred or unpacked, moisture condensation may occur inside the
machine. If you turn ON the machine while moisture is condensed on
its inner surface, the machine may become defective. To avoid such a
problem, be sure to allow the machine to stand at a room temperature
for a period of 1 hour or longer and then turn ON the power.
Check that the following component items are fully supplied. DICOM worklist (MWM) CL DICOM ORDER
1 O
key CD MWM
Hardware
Specified PC item DICOM worklist (MWM)
Specified monitor item key CD CL DICOM ID MWM 1 O
(patient information only)
Software
CR-IR 348CL Software Product (CD-R) DICOM PPS key CD CL DICOM MPPS 1 O
Option
DICOM Commitment Push CL DICOM
Description Product Code Qty. Remarks* 1 O
key CD COMMITMENT
Digital Mammography
Image data importing key CL USB STORAGE
key CD (image processing CL DICOM MAMMO P 1 O 1 O
CD FOR 358
parameters provided.)
* O: Option * O: Option
uuCAUTIONuu
For a PC provided with the source voltage changeover switch (between
115 and 230 VAC), set the PC source voltage according to the voltage
supplied to the institution concerned and then connect the power cable
to the power source.
Installation method 1
To continue to use the monitor rack, perform step 1. thereafter.
Installation method 2
To replace the monitor with a wall-mounting type monitor, replace first
the bracket with a wall-mounting type (option). Perform then step 1.
thereafter.
NOTE u
u l CPU and memory size shall be the same
When video board (Nanao SMD5-PCI) is installed to specified PC, BIOS as specified in the Operation Manual.
screen cannot be displayed. However, this is not the malfunction of the System - Processor Info (CPU of the specified computer model)
device.
System - Memory Info (At least the same as the memory capacity
If reference or setting of the BIOS is necessary, remove 3M video board
of the specified computer model)
(Nanao SMD5-PCI), and use the device connecting to an analog VGA
compliant monitor.
l The BIOS settings shall be as follows.
Onboard Device - USB Controller No Boot
Confirm and Change the BIOS settings according to the following procedure.
Security - Execute Disable Off
Performance - Multiple CPU Core On
1. Turn ON the PC power switch.
Performance - Speed Step Off
NOTE u
u
2. Press the <F2> key while the "DELL" window is displayed during If the setting for any item differs from the above, correct the setting.
start.
NOTE u
u
If the <F2> key is not pressed with the timeliness, the BIOS window will
not open. 4. Save the BIOS settings and reboot the PC.
In such a case, restart the PC to perform step 2. again.
REFERENCE
The character string entries in the [Administrator Password:]
and [Confirm Password:] fields appear as asterisks (*).
6. Click .
The date/time setup window opens.
REFERENCE
The “IP Address” and “Subnet Mask” fields are now ready to accept your
numerical value input.
REFERENCE
6. Click . Do not let the CL become a domain member.
The system returns then to the “Network Component Setup” window.
File copying starts automatically,
7. Click . It takes a few seconds to display the following and the PC restarts automatically after completion.
window (computer domain setup window). The “Display Settings” window opens.
After a while, the computer domain setup window opens.
9. Click [OK].
The “Monitor Settings” window opens.
NOTE
RI0000381.EPS
Then perform the following settings. (The following window may not be
displayed in some cases.) The system returns to the “User Accounts” window.
“How will this computer connect to the Internet ?” window.
Click [Skip]. 9. Select “iip” from the user account names.
“Ready to register with Microsoft ?”window The user account setup change window opens.
Click [No].
10. Select “Create Password”.
A window opens where the computer user is to be determined. The password creation window opens.
3. Enter any user name other than “Administrator” (“iip”, for instance), 11. Perform the following entries:
and click [Next].
A window opens to indicate completion of setup processing. : Enter “fcr-iip”.
4. Click [Finish].
: Enter “fcr-iip”.
After a while, the Windows desktop opens.
6. Select .
12. Click .
The “User Accounts” window opens. A window for file and/or folder settings will open.
7. Select .
17. Click the [Windows XP Tour] icon displayed 2. Click the “Settings” tab.
on the right side of the taskbar.
The XP tour starts.
RI0000354.EPS
18. Click [Cancel] to end the tour. 3. Complete monitor setup as directed below.
for more information. The screen area changes and the monitor setting window opens.
5. Click .
For other computers, refer to the manufacture's instructions.
NOTE
Click immediately. If it is not clicked in 15 seconds, the window returns
to the previous status.
2. Select .
6. Click .
The system returns to the “System Properties” window.
3. Doubl-click .
7. Click .
The system returns to the Control Panel.
The “System Properties” window opens.
8. Close control panel.
4. Click the “Advanced” tab and then click .
The system returns to the desktop.
RI0000357.EPS
RI000225.EPS
2. Double-click .
6. Click .
The system returns to the Control Panel.
The “Power Options Properties” window opens.
RI0000363.EPS
2. Double-click .
RI000226.EPS
5. Click .
The system returns to the Control Panel.
3. Click .
RI0000365.EPS
5. Click .
The system returns to the Control Panel.
Change the Windows taskbar display setting as follows. Make sure the network is properly configured at this time.
1. Right-click a position on the taskbar to select “Properties”. If it is not yet done, refer to IN-11 for the necessary information.
The “Taskbar and Start Menu Properties” window opens.
Place a checkmark to ( ).
RI0000361.EPS
RI0000364.EPS
Installing the touch panel driver and adjusting the touch 4.2.3 LCD Monitor SL-IC200
panel Install the video board driver and perform monitor setups.
For details on the procedures for setting up the touch-panel- attached For detailed setup procedure of the LCD Monitor SL-IC200,
monitor, see “Appendix 1 Installing the Touch Panel Driver [Option]” see manuals provided with the SL-IC200.
under “Appx IN: Appendix to Installation” in the Service Manual of the
CR-IR 346/348CL.
Width
Horizontal position
Height
Vertical position
Pincushion distortion
Screen rotation
For details on the adjustment procedures, see the documentation
supplied with the monitor.
Model L560T-C
Contrast : Default (not determined)
Brightness : 100%
NOTE u
u
For RU-CL N:N connection (when two or more CLs are connected), create
the FTP server only for the CL that will serve as the RU master-IIP.
REFERENCE
The IIS manager is a program used for creating an FTP server and comes
with the OS.
00000141.EPS
1. Insert the Windows reinstallation CD into the CD-ROM drive. 3. Don't place a checkmark to and
The “Welcome to Microsoft Windows XP” window opens. click .
4. Place a checkmark to ( )
and click .
5. Click .
6. Click .
RI0000358.EPS
The system returns to the “Welcome to Microsoft Windows XP” window.
7. Click .
REFERENCE
The service pack is a modification program that corrects various problems
with MSDE.
The “IIP Setup Tool” main menu automatically opens. As indicated in the following window illustration, the MSDE/service pack
installation process progresses.
MSDE and service pack installations end in about ten minutes in total.
RI000097.EPS
REFERENCE
“IIP Setup Tool” is a utility tool that performs CL-AP installation and other
tasks. This tool is stored on the CD that is supplied with the CL as a
standard accessory.
The installation menu for MSDE and its service pack opens.
REFERENCE
When you choose “6) Version Check”, you can view the version
information about MSDE and service pack.
00000178.EPS
3. Click .
When the 15" monitor with the touch panel is to be used, choose “Color In a few minutes, a window like that shown below opens.
(1024 × 768)”.
When the 17” monitor with the touch panel is to be used, choose “Color
(1280 × 1024)”.
When the color Super Resolution LCD SL-IC300 is to be used, select
“Color (2048 × 1536)”.
When the monochrome Super Resolution LCD SL-IC300 is used, RI000026.EPS
RI000032.EPS
00000180.EPS
RI000227.EPS
csp451001.ai
RI000105.EPS
csp451002.ai
RI000028.EPS
NOTE u
u
For Windows XP, you must perform driver software settings after USB
peripheral devices are connected.
For the driver software setup procedure, see “4.6 Changing the
Barcode Reader/Magnetic Card Reader Driver Software” under
“MT: Machine Troubleshooting” in the Service Manual of the CR-IR
346/348CL.
RI0000385.EPS
NOTE
When you have selected “For Digital X-ray (DX Storage Option)” at step
2 above, a window opens where whether or not to use the FNC (Flexible
Noise Control processing) parameters is specified. Enter an item
number that is for the menu to be used at the institution and then press
the <Enter> key.
● When English (U.S.) was selected as the language to be installed:
csp452001.ai
NOTE u
u
Do not select “20) Slovene” because software version V7.0 (B) does not
RI0000386.EPS
provide support to it.
● When a language other than English (U.S.) was selected:
RI0000384.EPS
RI0000386.EPS
RI0000384.EPS
NOTE u
u
Built_in Console must be installed even when only the RU or 5000 cassette-
type Image Reader is installed. If it is not installed, an error occurs when the
CL-AP starts running.
RI000031.EPS
RI000029.EPS
5. Click .
6. Click .
RI000097.EPS
2. Type in the number “4” and then press the <Enter> key.
The “Built_in Console Setup” window opens.
3. Click .
RI000030.EPS
The PC restarts.
NOTE u
u The “Risiip - Choose Program Group” window opens.
Even if the F-RIS function is not used, install the FRIS Modules. If they are
not installed, an error occurs when the CL-AP starts.
1. Start “IIP Setup Tool” and then choose “10) Install FRIS
Modules”.
REFERENCE
Insert or reinsert the CD-AP CD into the CD-ROM drive. The “IIP Setup
Tool” menu will then start up automatically. RI000044.EPS
4. Click .
The “Risiip Setup” window opens.
The following warning window opens.
RI000042.EPS R 000045.EPS
2. Click . 5. Click .
A window opens, prompting you to start the installation. The following window opens.
RI000043.EPS
RI000046.EPS
RI000047.EPS
7. Click .
RI000048.EPS
8. Click .
A message appears to indicate that the installation is completed.
RI000049.EPS
00000332.EPS 00000338.EPS
The installation start window for the HQ image transfer key opens.
REFERENCE
The above error window opens when the AP key is not installed.
This error screen does not imply any anomalies because the AP key will
6. In the same manner as indicated in steps 4. and 5. above,
consecutively install the HQ image transfer key, 5000 plus
be installed later in “4.9 AP Key Installation”. connection key, DRC image processing key, TAS image
processing key, image magnification or full screen display on
the QA window key [not available for Lite], other competing
2. Click . PACS connection key [not available for Lite], and Film annotation
characters key.
The system returns to the desktop screen.
7. Remove the CD from the CD-ROM drive.
Image
CL DICOM A function assuring that an image has surely
NOTE u
u storage
COMMITMENT been stored in the archiver unit.*2
After option key installation, be sure to install the AP key. The reason is that assurance
installing the option keys disables the AP key that has been enabled. IR 346 DELUX-QA QA function addition*3
QA function CL TILE-IM QA FOR
QA batch processing
PLUS
Function Product Code Description
IR 348 MFP MFP image processing
Print output IR346 DICOM PRINT DICOM Print function
CL SHUTTER-PROC Shuttering processing
DICOM-based image transmission functions
available (Also include a function to transmit CL PEM PEM image processing
unstandardized images to the QA-WS.)
CL IM COMPOSITION Image composition
IR346 DICOM CR Options installed are as follows.
STORAGE CR Storage SCU (Standard)
CL IM-MAGNIFY FOR
Image magnification (for Lite Standard Key)
CR Storage SCU (Private)
LITE
(“Private Unstandardized CR Storage” is Image
processing CL LUT-ADJUSTMENT LUT adjustment for connection to other
included in “Private”.)
FOR LITE competing PACS (for Lite Standard Key)
Functions available for processed-image
CL ANNOTATION
transmission with DICOM Options installed Annotation function
IR346 DICOM IM FOR LITE
are as follows.
PROCESSED
CR Storage SCU (Standard) CL GPR Grid Pattern Removal (GPR) function
Processed image generation
FCR QC TEST SOFT Image Reader QC function
Image Function for image transfer (input/output)
FCR QC TEST SOFT M Image Reader QC function
input/ with FINP Options installed are as follows.
IR346 DMS NET-WORK
output FINP output
*1 To use this option, the “CL DICOM MAMMO S” option key must have been
IN-OUT
FINP input
installed.
(Supports only the reprint function.) *2 To use this option, the “IR346 DICOM CR STORAGE” option key must have been
installed.
CR Digital Mammography function. Image
CL DICOM MAMMO S *3 When “IR346 DELUX-QA” is installed, all the QA functions are made available. If it
processing parameters will not be provided.
is not installed, only a limited number of QA functions available.
CR Digital Mammography function. Image
CL DICOM MAMMO P
processing parameters will be provided.*1
CL DICOM DVD
Removable media image storage function
STORAGE
Function for study query/image retrieval to/
CL DICOM QR
from filing devices.
CL DICOM PDI Function that writes exposed images onto a
STORAGE CD-R.
NOTE u
u
Before AP key installation, be sure to install a standard key and option keys.
2. Click .
00000456.EPS
3. Click .
The system returns to the desktop screen.
For the procedure to be used to delete images accumulated on the The password entry window opens.
image output queue, see “8.2 Clearing the Contents of the Image Output
Queue” under “MU: Maintenance Utility” in the Service Manual of the CR-
IR 346/348CL.
2. Click while holding down the <Shift> key on the shutdown window.
5. Click .
When images are accumulated on the image output queue
Delete images accumulated on the output queue.
The command prompt window opens. After several seconds, the For the procedure to be used to delete images accumulated on the
following message appears. image output queue, see “8.2 Clearing the Contents of the Image
Output Queue” under “MU: Maintenance Utility” in the Service
Manual of the CR-IR 346/348CL.
RI000106.EPS
For details, see “4. Display Optimization - LUT” under “MU: Maintenance
Utility” in the Service Manual of the CR-IR 346/348CL.
2. Click on the host name in the left-hand pane and then click on
“Default FTP Site” in the right-hand pane. RI000073.EPS
RI000072.EPS
csp413001.ai
6. Click .
You are then returned to the “Internet Information Services” window.
NOTE u
u NOTE u
u
A window like that shown below opens in case the date and time If the above window does not open or an error display appears, note
displayed on the PC are older than those when it was started last the displayed error code and the applicable remedy, and then make
time. necessary corrections to achieve AP startup.
Click [OK] on the window that opens, and set correct date and time on See “1. Error Code Table” under “MT: Machine Troubleshooting” in
the “Date/Time Properties” window. the Service Manual of the CR-IR 346/348CL.
1. Set the current date/time. The CL-AP exits and the system returns to the desktop screen.
2. Turn the power to the PC OFF and disconnect the power cable from
the outlet. REFERENCE
3. After a few minutes, re-connect the power cable and turn the power to To shut down both the CL-AP and Windows, click [OK] without pressing
the PC ON again. the <Shift> key.
4. Check to see that the set date/time are correct. If the date/time values To shut down the CL-AP only, click [OK] while holding down the <Shift>
revert back to those before settings, have the battery be changed. key.
If the application does not start with the error code of 20110, and the Event Viewer says MAC address acquisition error,
then enter the correct MAC address in the Service Utility.
Refer to the service manual "3.14 MAC Address Manual Input" for more information.
The two types of settings, exceptional settings and communication protocol ➔ The “Add a Program” window opens.
ICMP settings, are performed on the Firewall window.
■ Exceptional settings
csp415001.ai
4. Click .
20000004.EPS
csp415002.ai
C:\Program Files\fujifilm\IIP\System\DicomStoreSCP.exe
C:\Program Files\fujifilm\IIP\System\IipMedia.exe 6. Click with the program to be added being selected
C:\Program Files\FujiFilm\IIP\System\ML_UPSEvent.exe appropriately.
C:\Program Files\FujiFilm\IIP\System\IIPUserUtility.exe ➔ The system returns to the Windows Firewall window.
C:\Program Files\FujiFilm\IIP\System\IIPServiceUtility.exe
C:\Program Files\fujifilm\FCR For installing 7. Make sure that a checkmark is placed to the left of the added
\TOOL\BmpServer\BmpServer.exe the RU PC-TOOL. execution file displayed in the Programs and Services field.
C:\Program Files\fujifilm\FCR\TOOL For installing
\InfoHostServer\InfoHostServer.exe the FCR-TOOL.
C:\Program Files\Microsoft ActiveSync\wcescomm.exe When the POCKET id
Console is used.
C:\Program Files\NetMeeting\conf.exe
C:\WINDOWS\SYSTEM32\FTP.exe
C:\WINDOWS\SYSTEM32\mnmsrvc.exe
C:\WINDOWS\SYSTEM32\INETSRV\inetinfo.exe For installing
the client RU PC-TOOL.
C:\Program Files\FujiFilm\WOL\FF-WakeOnLAN.exe When WakeOnLAN
is used.
C:\Program Files\FujiFilm\WOL\FF-WakeOnLAN Utility.exe When WakeOnLAN
is used.
C:\Program Files\fujifilm\IIP\System\Retrieve.exe
C:\Program Files\fujifilm\IIP\System\IIPRetakeAnalysisTool.exe
C:\Program Files\fujifilm\IIP\System\IIPTRISScreen.exe
C:\Program Files\fujifilm\IIP\System\IdLoginExe.exe 20000006.EPS
9. Click .
I
II
III
20000008.EPS
20000007.EPS
III. ➔
11. Click .
➔ The system returns to the Windows Firewall window.
csp415005.ai
3. Click .
➔ The system returns to the Windows Firewall window.
20000012.EPS
20000011.EPS
3. Click .
The CL system information setup items appear.
00000132.EPS
00000160.EPS
4. Click .