Applicable standards 1.2 External Dimensions, Part Names, and Terminal Layout 3. Wiring
FX5-4AD-ADP comply with the EC Directive (EMC Directive) and UL standards (UL, Unit: mm
cUL). Further information can be found in the following manual. [10] WIRING PRECAUTIONS
→ MELSEC iQ-F FX5U User's Manual (Hardware) [5]
→ MELSEC iQ-F FX5UC User's Manual (Hardware) [3] [4] Terminal • Make sure to cut off all phases of the power supply externally before
MELSEC iQ-F FX5-4AD-ADP Regarding the standards that relate to the CPU module, please refer to either the
product catalog or consult with your nearest Mitsubishi product provider.
[6] layout
V1+
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Attention [2] • Make sure to properly wire to the terminal block (European type) in
I1+
Hardware Manual
106
Manual Number JY997D60201
90
within conductive control cabinets. Please use the programmable controller while [1]
COM2 in the manual.
Revision E installed within a conductive shielded control cabinet. Installation within a control - Tightening torque should follow the specifications in the manual.
V3+
cabinet greatly affects the safety of the system and aids in shielding noise from the
Date June 2017 I3+ - Twist the ends of stranded wires and make sure that there are no loose
programmable controller.
wires.
• Control cabinet COM3
- Do not solder-plate the electric wire ends.
- The control cabinet must be conductive. V4+
- Do not connect more than the specified number of wires or electric wires
This manual describes the part names, dimensions, installation, and - Ground the control cabinet with the thickest possible grounding cable. I4+ of unspecified size.
specifications of the product. Before use, read this manual and manuals of - To ensure that there is electric contact between the control cabinet and its door, 8
[9] COM4 - Affix the electric wires so that neither the terminal block nor the connected
relevant products fully to acquire proficiency in handling and operating the connect the cabinet and its doors with thick wires. 15.1
74 15.1 parts are directly stressed.
product. Make sure to learn all the product information, safety information, and - In order to suppress the leakage of radio waves, the control cabinet structure
precautions. must have minimal openings. Also, wrap the cable holes with a shielding cover or 17.6
And, store this manual in a safe place so that you can take it out and read it other shielding devices. Special adapter WIRING PRECAUTIONS
[11]
whenever necessary. Always forward it to the end user. connector cover is
- The gap between the control cabinet and its door must be as small as possible by
Registration: removed • When drilling screw holes or wiring, make sure that cutting and wiring debris
attaching EMI gaskets between them.
The company name and the product name to be described in this manual are the Weight: Approx. 0.1 kg do not enter the ventilation slits of the PLC.
registered trademarks or trademarks of each company. Outer painting color: Munsell 0.6B7.6/0.2 Failure to do so may cause fire, equipment failures or malfunctions.
Shielding cover • Make sure to observe the following precautions in order to prevent any
Effective June 2017 Shielded cable [1] DIN rail mounting groove (DIN rail: DIN46277, 35 mm wide)
damage to the machinery or accidents due to malfunction of the PLC caused
Specifications are subject to change without notice. [2] Name plate
by abnormal data written to the PLC due to the effects of noise:
© 2015 MITSUBISHI ELECTRIC CORPORATION [3] Expansion adapter slide lock
1) Do not bundle the power line or analog input/output cable together with or
[4] Expansion adapter connector cover lay them close to the main circuit, high-voltage line, load line or power
EMI gasket [5] Direct mounting hole: 2 holes of φ4.5 (mounting screw: M4 screw) line. As a guideline, lay the power line, control line and communication
Wires*1 [6] PWR LED (green) cables at least 100 mm away from the main circuit, high-voltage line, load
Safety Precautions (Read these precautions before use.) *1 These wires are used to improve the conductivity between the door and control [7] Terminal block (European type terminal block) line or power line.
This manual classifies the safety precautions into two categories: cabinet. 2) Ground the shield of the analog input/output cable at one point on the
[8] Expansion adapter connector
and . • Cables [9] DIN rail mounting hook signal receiving side.
- Make sure to use shielded cables as cables pulled out of the control cabinet. However, do not use common grounding with heavy electrical systems.
[10] Expansion adapter fixing hook
Indicates that incorrect handling may cause hazardous - Connect the shield such as shielded cables and shielding covers to the grounded [11] Expansion adapter connector 3.1 Cable end treatment and tightening torque
conditions, resulting in death or severe injury. control cabinet.
• It is possible that the accuracy temporarily fluctuates within ±10 %. 3.1.1 European type terminal block
Indicates that incorrect handling may cause hazardous 2. Installation 1) Suitable wiring
conditions, resulting in minor or moderate injury or • Set the number of times of winding to "2 turns" within approximately 200 mm from
property damage. the terminal block of the analog cable on the FX5-4AD-ADP side, and attach a INSTALLATION
No. of wire Wire size
ferrite core. (Ferrite core used in our test: E04SR401938 manufactured by SEIWA PRECAUTIONS
ELECTRIC MFG. CO., LTD.) per terminal Single wire, Strand wire Ferrules with insulating sleeve
Depending on the circumstances, procedures indicated by may also • Make sure to cut off all phases of the power supply externally before attempting
cause severe injury. installation or wiring work. AWG22 to 20 AWG22 to 20
1. Outline One wire
It is important to follow all precautions for personal safety. Failure to do so may cause electric shock or damage to the product. (0.3 to 0.5 mm2) (0.3 to 0.5 mm2)
The FX5-4AD-ADP expansion adapter for analog input (hereinafter called 4AD-ADP) is
a expansion adapter to add four analog input points. • Use the product within the generic environment specifications described in the Two wires AWG22 (0.3 mm2) -
Associated Manuals User's Manual (Hardware) of the CPU module used.
1.1 Incorporated Items Never use the product in areas with excessive dust, oily smoke, conductive dusts, 2) Tightening torque
Manual name Manual No. Description Verify that the following product and items are included in the package: corrosive gas (salt air, Cl 2 , H 2 S, SO 2 or NO 2 ), flammable gas, vibration or Tighten the terminal screws with 0.20 N•m.
impacts, or expose it to high temperature, condensation, or rain and wind. Do not tighten the screws outside the specified torque.
Explains FX5U PLC
MELSEC iQ-F Product FX5-4AD-ADP analog input expansion adapter If the product is used in such conditions, electric shock, fire, malfunctions, Failure to do so may cause equipment failures or malfunctions.
specification details for I/O,
FX5U User's Manual JY997D55301 deterioration or damage may occur. 3) Wire end treatment
wiring, installation, and Included Items Hardware manual (This manual)
(Hardware) Strip the coating of strand wire and twist the cable core before connecting it,
maintenance.
INSTALLATION or strip the coating of single wire before connecting it.
Explains FX5UC PLC PRECAUTIONS When using a wire ferrule with an insulating sleeve, choose a wire with
MELSEC iQ-F
specification details for I/O, proper cable sheath referring to the above outside dimensions, otherwise
FX5UC User's Manual JY997D61301
wiring, installation, and • Do not touch the conductive parts of the product directly. the wire cannot be inserted easily.
(Hardware)
maintenance. Doing so may cause device failures or malfunctions.
- Strand wire/single wire - Ferrule with insulation sleeve
MELSEC iQ-F Describes the analog • When drilling screw holes or wiring, make sure that cutting and wiring debris do
not enter the ventilation slits of the PLC. Insulation sleeve Contact area
FX5 User's Manual function of the CPU module (Crimp area)
JY997D60501 Failure to do so may cause fire, equipment failures or malfunctions.
(Analog Control - CPU module built-in and the analog
built-in, Expansion adapter) adapter. • Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
9 mm
thereby causing nonconformities. 8 mm
How to obtain manuals
For the necessary product manuals or documents, consult with your local • Install the product securely using a DIN rail or mounting screws.
2.6 mm
Mitsubishi Electric representative. • Connect the expansion board and expansion adapter securely to their designated 14 mm
connectors.
Loose connections may cause malfunctions. <Reference>
For the installation, refer to the following manual. Manufacturer Model Caulking tool
→ MELSEC iQ-F FX5U User's Manual (Hardware)
→ MELSEC iQ-F FX5UC User's Manual (Hardware) PHOENIX CONTACT CRIMPFOX 6
AI 0.5-8 WH
GmbH & Co. KG CRIMPFOX 6T-F
*1 820 k 4.2 General Specifications Number of occupied 0 point (This number is not related to the maximum number of
CH
V+ The items other than the following are equivalent to those of the CPU module. I/O points I/O points of the PLC.)
250
I+ 180 k For general specifications, refer to the following manual.
COM → MELSEC iQ-F FX5U User's Manual (Hardware) *1 For the input conversion characteristic, refer to the following.
→ MELSEC iQ-F FX5UC User's Manual (Hardware) → MELSEC iQ-F FX5 User's Manual (Analog Control - CPU module built-in,
Expansion adapter)
V +, I+, COM, CH: represents the channel number. Item Specification *2 This specification does not apply to products manufactured before June 2016.
*1 Use 2-core shielded twisted pair cable for the analog input lines, and Dielectric withstand
500 V AC for one minute Between all external
separate the analog input lines from other power lines or inductive lines. voltage
terminals and ground
*2 Make sure to short-circuit the 'V+' and 'I+' terminals when current is 10 MΩ or higher by 500 V DC terminal of CPU module
Insulation resistance
input. (: input channel number) insulation resistance tester
3.3 Grounding 4.3 Power Supply Specifications
Grounding should be performed as stated below.
• The grounding resistance should be 100 Ω or less. Item Specification
• Independent grounding should be performed for best results. 24 V DC 20 mA
Internal electric supply
When independent grounding is not performed, perform "shared grounding" of Internal electric supply is carried out from 24 V DC power
(A/D conversion circuit)
the following figure. supply of a CPU module.
For the details, refer to the following manual.
5 V DC 10 mA
→ MELSEC iQ-F FX5U User's Manual (Hardware) Internal electric supply
→ MELSEC iQ-F FX5UC User's Manual (Hardware) Internal electric supply is carried out from 5 V DC power
(Interface)
supply of a CPU module.
Othere Othere Othere
PLC quipment PLC quipment PLC quipment
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
JY997D60201E Side
B
Side
A JAPANESE
Side
B ENGLISH
Applicable standards 1.2 External Dimensions, Part Names, and Terminal Layout 3. Wiring
FX5-4AD-ADP comply with the EC Directive (EMC Directive) and UL standards (UL, Unit: mm
cUL). Further information can be found in the following manual. [10] WIRING PRECAUTIONS
→ MELSEC iQ-F FX5U User's Manual (Hardware) [5]
→ MELSEC iQ-F FX5UC User's Manual (Hardware) [3] [4] Terminal • Make sure to cut off all phases of the power supply externally before
MELSEC iQ-F FX5-4AD-ADP Regarding the standards that relate to the CPU module, please refer to either the
product catalog or consult with your nearest Mitsubishi product provider.
[6] layout
V1+
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Attention [2] • Make sure to properly wire to the terminal block (European type) in
I1+
Hardware Manual
106
Manual Number JY997D60201
90
within conductive control cabinets. Please use the programmable controller while [1]
COM2 in the manual.
Revision E installed within a conductive shielded control cabinet. Installation within a control - Tightening torque should follow the specifications in the manual.
V3+
cabinet greatly affects the safety of the system and aids in shielding noise from the
Date June 2017 I3+ - Twist the ends of stranded wires and make sure that there are no loose
programmable controller.
wires.
• Control cabinet COM3
- Do not solder-plate the electric wire ends.
- The control cabinet must be conductive. V4+
- Do not connect more than the specified number of wires or electric wires
This manual describes the part names, dimensions, installation, and - Ground the control cabinet with the thickest possible grounding cable. I4+ of unspecified size.
specifications of the product. Before use, read this manual and manuals of - To ensure that there is electric contact between the control cabinet and its door, 8
[9] COM4 - Affix the electric wires so that neither the terminal block nor the connected
relevant products fully to acquire proficiency in handling and operating the connect the cabinet and its doors with thick wires. 15.1
74 15.1 parts are directly stressed.
product. Make sure to learn all the product information, safety information, and - In order to suppress the leakage of radio waves, the control cabinet structure
precautions. must have minimal openings. Also, wrap the cable holes with a shielding cover or 17.6
And, store this manual in a safe place so that you can take it out and read it other shielding devices. Special adapter WIRING PRECAUTIONS
[11]
whenever necessary. Always forward it to the end user. connector cover is
- The gap between the control cabinet and its door must be as small as possible by
Registration: removed • When drilling screw holes or wiring, make sure that cutting and wiring debris
attaching EMI gaskets between them.
The company name and the product name to be described in this manual are the Weight: Approx. 0.1 kg do not enter the ventilation slits of the PLC.
registered trademarks or trademarks of each company. Outer painting color: Munsell 0.6B7.6/0.2 Failure to do so may cause fire, equipment failures or malfunctions.
Shielding cover • Make sure to observe the following precautions in order to prevent any
Effective June 2017 Shielded cable [1] DIN rail mounting groove (DIN rail: DIN46277, 35 mm wide)
damage to the machinery or accidents due to malfunction of the PLC caused
Specifications are subject to change without notice. [2] Name plate
by abnormal data written to the PLC due to the effects of noise:
© 2015 MITSUBISHI ELECTRIC CORPORATION [3] Expansion adapter slide lock
1) Do not bundle the power line or analog input/output cable together with or
[4] Expansion adapter connector cover lay them close to the main circuit, high-voltage line, load line or power
EMI gasket [5] Direct mounting hole: 2 holes of φ4.5 (mounting screw: M4 screw) line. As a guideline, lay the power line, control line and communication
Wires*1 [6] PWR LED (green) cables at least 100 mm away from the main circuit, high-voltage line, load
Safety Precautions (Read these precautions before use.) *1 These wires are used to improve the conductivity between the door and control [7] Terminal block (European type terminal block) line or power line.
This manual classifies the safety precautions into two categories: cabinet. 2) Ground the shield of the analog input/output cable at one point on the
[8] Expansion adapter connector
and . • Cables [9] DIN rail mounting hook signal receiving side.
- Make sure to use shielded cables as cables pulled out of the control cabinet. However, do not use common grounding with heavy electrical systems.
[10] Expansion adapter fixing hook
Indicates that incorrect handling may cause hazardous - Connect the shield such as shielded cables and shielding covers to the grounded [11] Expansion adapter connector 3.1 Cable end treatment and tightening torque
conditions, resulting in death or severe injury. control cabinet.
• It is possible that the accuracy temporarily fluctuates within ±10 %. 3.1.1 European type terminal block
Indicates that incorrect handling may cause hazardous 2. Installation 1) Suitable wiring
conditions, resulting in minor or moderate injury or • Set the number of times of winding to "2 turns" within approximately 200 mm from
property damage. the terminal block of the analog cable on the FX5-4AD-ADP side, and attach a INSTALLATION
No. of wire Wire size
ferrite core. (Ferrite core used in our test: E04SR401938 manufactured by SEIWA PRECAUTIONS
ELECTRIC MFG. CO., LTD.) per terminal Single wire, Strand wire Ferrules with insulating sleeve
Depending on the circumstances, procedures indicated by may also • Make sure to cut off all phases of the power supply externally before attempting
cause severe injury. installation or wiring work. AWG22 to 20 AWG22 to 20
1. Outline One wire
It is important to follow all precautions for personal safety. Failure to do so may cause electric shock or damage to the product. (0.3 to 0.5 mm2) (0.3 to 0.5 mm2)
The FX5-4AD-ADP expansion adapter for analog input (hereinafter called 4AD-ADP) is
a expansion adapter to add four analog input points. • Use the product within the generic environment specifications described in the Two wires AWG22 (0.3 mm2) -
Associated Manuals User's Manual (Hardware) of the CPU module used.
1.1 Incorporated Items Never use the product in areas with excessive dust, oily smoke, conductive dusts, 2) Tightening torque
Manual name Manual No. Description Verify that the following product and items are included in the package: corrosive gas (salt air, Cl 2 , H 2 S, SO 2 or NO 2 ), flammable gas, vibration or Tighten the terminal screws with 0.20 N•m.
impacts, or expose it to high temperature, condensation, or rain and wind. Do not tighten the screws outside the specified torque.
Explains FX5U PLC
MELSEC iQ-F Product FX5-4AD-ADP analog input expansion adapter If the product is used in such conditions, electric shock, fire, malfunctions, Failure to do so may cause equipment failures or malfunctions.
specification details for I/O,
FX5U User's Manual JY997D55301 deterioration or damage may occur. 3) Wire end treatment
wiring, installation, and Included Items Hardware manual (This manual)
(Hardware) Strip the coating of strand wire and twist the cable core before connecting it,
maintenance.
INSTALLATION or strip the coating of single wire before connecting it.
Explains FX5UC PLC PRECAUTIONS When using a wire ferrule with an insulating sleeve, choose a wire with
MELSEC iQ-F
specification details for I/O, proper cable sheath referring to the above outside dimensions, otherwise
FX5UC User's Manual JY997D61301
wiring, installation, and • Do not touch the conductive parts of the product directly. the wire cannot be inserted easily.
(Hardware)
maintenance. Doing so may cause device failures or malfunctions.
- Strand wire/single wire - Ferrule with insulation sleeve
MELSEC iQ-F Describes the analog • When drilling screw holes or wiring, make sure that cutting and wiring debris do
not enter the ventilation slits of the PLC. Insulation sleeve Contact area
FX5 User's Manual function of the CPU module (Crimp area)
JY997D60501 Failure to do so may cause fire, equipment failures or malfunctions.
(Analog Control - CPU module built-in and the analog
built-in, Expansion adapter) adapter. • Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
9 mm
thereby causing nonconformities. 8 mm
How to obtain manuals
For the necessary product manuals or documents, consult with your local • Install the product securely using a DIN rail or mounting screws.
2.6 mm
Mitsubishi Electric representative. • Connect the expansion board and expansion adapter securely to their designated 14 mm
connectors.
Loose connections may cause malfunctions. <Reference>
For the installation, refer to the following manual. Manufacturer Model Caulking tool
→ MELSEC iQ-F FX5U User's Manual (Hardware)
→ MELSEC iQ-F FX5UC User's Manual (Hardware) PHOENIX CONTACT CRIMPFOX 6
AI 0.5-8 WH
GmbH & Co. KG CRIMPFOX 6T-F
*1 820 k 4.2 General Specifications Number of occupied 0 point (This number is not related to the maximum number of
CH
V+ The items other than the following are equivalent to those of the CPU module. I/O points I/O points of the PLC.)
250
I+ 180 k For general specifications, refer to the following manual.
COM → MELSEC iQ-F FX5U User's Manual (Hardware) *1 For the input conversion characteristic, refer to the following.
→ MELSEC iQ-F FX5UC User's Manual (Hardware) → MELSEC iQ-F FX5 User's Manual (Analog Control - CPU module built-in,
Expansion adapter)
V +, I+, COM, CH: represents the channel number. Item Specification *2 This specification does not apply to products manufactured before June 2016.
*1 Use 2-core shielded twisted pair cable for the analog input lines, and Dielectric withstand
500 V AC for one minute Between all external
separate the analog input lines from other power lines or inductive lines. voltage
terminals and ground
*2 Make sure to short-circuit the 'V+' and 'I+' terminals when current is 10 MΩ or higher by 500 V DC terminal of CPU module
Insulation resistance
input. (: input channel number) insulation resistance tester
3.3 Grounding 4.3 Power Supply Specifications
Grounding should be performed as stated below.
• The grounding resistance should be 100 Ω or less. Item Specification
• Independent grounding should be performed for best results. 24 V DC 20 mA
Internal electric supply
When independent grounding is not performed, perform "shared grounding" of Internal electric supply is carried out from 24 V DC power
(A/D conversion circuit)
the following figure. supply of a CPU module.
For the details, refer to the following manual.
5 V DC 10 mA
→ MELSEC iQ-F FX5U User's Manual (Hardware) Internal electric supply
→ MELSEC iQ-F FX5UC User's Manual (Hardware) Internal electric supply is carried out from 5 V DC power
(Interface)
supply of a CPU module.
Othere Othere Othere
PLC quipment PLC quipment PLC quipment
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN