Cable Type Power Cable

Number of Core 4 core single insulated cable


Proposed Brand Master Tec
Location to be used Station, Depot building
Used in KTMBProject No
Used in Other Railway Project No

Comply Sub Contractor


Specification Clause Description
Yes No Comment/Remark

The Contractor shall supply and install all telecommunications wires and
cables between the equipment and distribution frames/ shelves, all wiring
associated with power supplies, both AC and DC and all wiring associated
with earthing. Every cable must be indelibly labelled/ sign written not further
System tech Spec 13.13.4 Yes noted
than 150mm from each end with a legend that uniquely and easily identifies
its function, local and far end connections. Factory terminated and tested
cabled should be used wherever possible to limit the possibility if faulty
connections.
Power supply wiring cables (both AC and DC) shall be of single core insulated
copper conductors confirming to BS 6004. AC mains cables must carefully
segregated from all others by being insulated in separate (or divided) trunking - comply with IEC 60502-1
where conduits are not used. DC power supply cabling shall have the following - PVC cable with rated voltage 600/1000V
System tech Spec 13.13.5 Yes
colour code: - Conductor material : Plain annealed copper wire same
Positive (earth) - black with bs 6004
Negative - blue
AC power shall be taken from a local isolator or fused spur.