Вы находитесь на странице: 1из 1

UG-129 ASME BPVC.VIII.

1-2015

be plainly marked by the Manufacturer or Assembler with


Figure UG-129.1
the required data in such a way that the marking will not
Official Certification Mark to Denote the
be obliterated in service. The marking may be placed on
American Society of Mechanical Engineers’
the valve or on a metal plate or plates securely fastened
Standard for Pressure Relief Valves
to the valve.
(1) the name, or an acceptable abbreviation, of the
Manufacturer and the Assembler;
(2) Manufacturer’s design or type number;
(3) NPS size (DN) __________ (the nominal pipe size of
the valve inlet);
(4) set pressure __________ psi (kPa), and, if applicable
per UG-136(d)(4), cold differential test pressure __________
psi ( kPa); UV

(5) certified capacity (as applicable):


(-a) lb/hr (kg/hr) of saturated steam at an over-
pressure of 10% or 3 psi (20 kPa), whichever is greater rated capacity in terms of other fluids shall be determined
for valves certified on steam complying with UG-131(b); by the method of conversion given in Mandatory Appen-
or dix 11. [See UG-131(h).]
(-b) gal/min (l/min) of water at 70°F (20°C) at an (c) Pressure Relief Valves in Combination With Rupture
overpressure of 10% or 3 psi (20 kPa), whichever is Disk Devices. Pressure relief valves in combination with
greater for valves certified on water; or rupture disk devices shall be marked with the capacity
(-c) SCFM (standard cubic feet per minute at 60°F as established in accordance with UG-127(a)(3)(-b)(-2)
and 14.7 psia) [m3/min (cubic meters per minute at 20°C (using 0.90 factor) or the combination capacity factor es-
and 101 kPa)], or lb/min (kg/min), of air at an overpres- tablished by test in accordance with UG-132(a) or
sure of 10% or 3 psi (kPa), whichever is greater. Valves UG-132(b), in addition to the marking of (a) and (e) be-
that are capacity certified in accordance with low. The marking may be placed on the pressure relief
UG-131(c)(2) shall be marked “at 20% overpressure.” valve or rupture disk device or on a plate or plates that
(-d) In addition to one of the fluids specified satisfy the requirements of UG-119. The marking shall in-
above, the Manufacturer may indicate the capacity in clude the following:
other fluids (see Mandatory Appendix 11). (1) name of Manufacturer of valve;
(6) year built, or alternatively, a coding may be (2) design or type number of valve;
marked on the valve such that the valve Manufacturer (3) name of Manufacturer of rupture disk device;
or Assembler can identify the year the valve was as-
(4) design or type number of rupture disk device;
sembled or tested;
(7) the Certification Mark with the UV Designator (5) capacity or combination capacity factor;
placed under the Mark, as shown in Figure UG-129.1. A (6) name of organization responsible for this mark-
marking method other than the stamp issued by the So- ing. This shall be either the vessel user, vessel Manufac-
ciety may be used provided it is acceptable to the ASME- turer, rupture disk Manufacturer, or pressure relief
designated organization. The pilot of a pilot operated valve Manufacturer.
pressure relief valve shall be plainly marked by the Man-
ufacturer or Assembler showing the name of the Manufac-
turer, the Manufacturer’s design or type number, the set Figure UG-129.2
pressure in pounds per square inch (kPa), and the year Official Certification Mark to Denote the
built, or alternatively, a coding that the Manufacturer American Society of Mechanical Engineers’
can use to identify the year built. Standard for Nonreclosing Pressure Relief
On valves smaller than NPS 1/2 (DN 15), the markings Devices
may be made on a metal plate attached by wire or adhe-
sive meeting the requirements of Mandatory Appendix 18
or other means suitable for the service conditions.
(8) restricted lift _______________ in. (mm) (For re-
stricted lift valves only)
(b) Safety and safety relief valves certified for a steam
discharging capacity under the provisions of Section I
and bearing the Certification Mark with the V Designator UD
for safety valves may be used on pressure vessels. The

92