Continuous Leak Test


Measurement accuracy 0,01 Pa
Dual mode operation "Continuous flow" and “single test"

APPLICATION FIELDS

PRODUCT CONFIGURATOR M8970 is the new Entry Level Leak Test Continuous of ForTest® M series.

This instrument, ideal for testing kitchen hobs or however particulars of gas
sector, basically works in two distinct modes, "Continuous flow" and "Single
test", suitable for two different kinds of uses.
TECNICAL DATA
"Continuous flow" is ideal to make analysis and repairs during leak test, in fact
­ Black anodized aluminium case
the filling phase occurs automatically (without the start command) and the leak
­ “No break­through” plexiglass front panel
measurement is expressed in a volumetric way (cc/h) or in pressure (dp/dt),
­ Display of test pressure and of pressure decay in: mbar / mbar/s / Pa / hPA
allowing the operator to measure continuously and automatically the piece under
/ cc/min / cc/h
open in browser customize free license pdfcrowd.com
/ cc/min / cc/h
­ LCD display: 240x64 pixels and blue back­illumination test during repairs and adjustments.
­ Graphic display of the leak test on Cartesian coordinate plane
In "Single test" mode the instrument works in a traditional way, detecting leaks
­ Mechanical pressure regulator
­ Electronic pressure regulator on demand and ending test with Good or Bad result.
­ Measurement Accuracy better than 0,01 Pa The revolutionary Flash technology with ultra fast elaboration times allows to
­ Pieces Counter and Real time Clock Memory have a graphic display with Cartesian coordinate plane and with auto scale of
­ Possibility to set up till 100 test programs the leak test.
­ Calibration according to ISO rules (Menu accessible to the user and
concealed by a control algorithm) This equipment is available with test pressure from 0,2 to 1 bar.
­ Connector with 24 Vdc expansion signals
­ RS232 opto isolated port M8970 has got a 24 Vdc Aux connector for expansion signals, a USB port, a
­ Opto isolated Port for industrial multi points networks RS232 opto isolated port and a opto isolated port for industrial multi test stations
­ USB port for PC connection networks. We can supply also external accessories as: printers, Staubli fittings
­ USB flash drive to record the tests, radio remote control to manage the for the connection to the front panel of M0710 (calibrated leaks), kits network
tests, Bluetooth, Ethernet and Internet direct connections (on request) sorting for the realization of complex PC networks, mechanical precise
­ Working temperature min. 5°C / max. 40 °C regulators etc …
­ Weight for the basic version: 8 kg.
­ Dimensions: 270X160X300 mm. If requested, it is possible to install a USB flash drive to record the tests, radio
remote control to manage the tests, Bluetooth, Ethernet and Internet direct
connections.
­ Pressure full scale: (mbar) 200; 500; 1000
­ Power supply: 110 Vac 50/60Hz,230 Vac 50/60Hz
­ Different pneumatics available for tubes (mm): 4x2,7,6x4,8x6 Thanks to its renewed hardware M8970 shows a measurement accuracy of 0,01
­ Test Gas: Hidrogen,Refrigerant,Compressed air,Nitrogen,Helium Pa which allows to make tests at the highest quickness and reliability possible
in air leak test field. The equipment also has got: a very simple user interface,
OPTIONALS multi language menu, bar graph indicator which shows test pressure and the
detected decay, RGB led to show good or bad result.

Frontal connector for Staubli calibrated leak Standard equipment has got a mechanical pressure regulator, on demand it is
Frontal precision pressure regulator possible to install a high precision electronic pressure regulator.
Electronic pressure Regulator
Auto zero primary pressure circuit
Pre­Filling
Secondary Output of Waste (third result)
Leak Analog Output
I/O 24 Vdc expansion signal card
Ethernet plug/TCP­IP
Active USB port
Bluetooth connection
Radio remote control selection Kit
High­Resolution measure (1M pti AD) ­ (DI SERIE) ­
Capacitance meter for piece volume measure ­ (DI SERIE) ­

ACCESSORIES
open in browser customize free license pdfcrowd.com
External exhaust solenoid
External start button
External start/abort pushbutton
External pushbutton 4 programmes selection
Start pedal
Barcod reader
Thermal printer
Adhesive label for printer 4500pcs
Aux signals extension cable
Air filter
Staubli male connector
Precision micrometer nozzle
Micrometer nozzle
M series manager software
TTY
Serial protocol
PC serial cable owner ­­­> M Series
External temperature probe

Click to enlarge

Contacts
Set up your product Discover our services Find your dealer Tel. +(39) 0535 731530
for leak testing email info@fortest.com

© 2009 ­ 2010 ForTest Italia Srl ­ VAT Code 02934911203 ­ All Rights Reserv ed ­ Company Info ­ Priv acy ­ Credits

open in browser customize free license pdfcrowd.com

Вам также может понравиться