Вы находитесь на странице: 1из 2

S-0701-PE

Revision No. Issued Date


01 18 Jun. 2018

Chief Engineer’s Report


For CMS Confirmatory Survey

Ship’s Name Flag : Class No. :


No.2 GREEN PIONEER JEJU ( KOREA) 0254539
Owner’s Name(management Company’s Name):
GSM CO.LTD
C/E’s Name : Nationality of C/E : KOREA
CHOI CHANG HA
C/E’s License No.: BS-E1-15-0227 Validity of C/E’s License : Apr.20.2020

Country who issued License : No. of License endorsed by the flag :


BUSAN KOREA

I, the undersigned Chief Engineer of the above ship, have carried out “Open up Inspection” of the
CMS Items as reported in the attached “Detailed Report of Open up inspection”

Total No. of machinery / equipment inspected by C/E : 1 SET


Date of Signature of C/E : 28TH FEB 2020

Signature of C/E :

(C/E’s Name) ( CHOI CHANG HA )

Confirmatory Survey by Surveyor


I, the undersigned surveyor, have carried out “Confirmatory Survey” of the CMS Items inspected by
Chief Engineer in open up condition, and confirmed that all of the CMS Items are maintained in
good order, or placed to good working order.

Date :
Port : (Signature)
( )
Survey to Class

This format is to be used to report the results of C/E’s open up inspection. In case where any machinery and
equipment is to be open within due date by the Chief Engineer, this Report is to be prepared and submitted to
the Surveyor on or before the forthcoming periodical survey. This report is to be prepared 2 sets and 1set is
to be put in class survey record File with endorsement by the Surveyor.

GSM CO., LTD.


S-0701-PE
Revision No. Issued Date
01 18 Jun. 2018

Details of Open up Inspection by C/E


Name & No. of equipment : Date of C/E’s Inspection : Place of Inspection :

No.1(C) CARGO PUMP


MARFLEX-BV 28TH FEB 2020 AT SEA
MODEL: MTDP-80

Condition before and after reassembly :


Before overhauled:
- Working as normal condition
- Purging result: 0.4 ltrs mixing cargo and lubricant
After overhauled:
- Working as normal condition
- Purging has nothing

Contents of overhaul/inspection/maintenance/repair etc :


(measurement records attached : Yes
- The following surveys and examination were carried out:
Opened up the p/p for inspection internal parts as the impeller, shaft, ball bearing, roller bearing,
double cargo seal, single cargo seal, oil seal, upper and lower sleeve, wearing ring found the
wearing little worn out. Renewed wear ring, double cargo seal, single cargo seal, oil seal,all of o-
rings. Reassembly the pump then trial found satisfactory.

Name of parts replaced/repaired:


The parts renewed as following:
- Wear ring part no.667053
- Double cargo seal part no.668944
- Single cargo seal part no.668943
- Oil seal part no.081120
- O-rings part no.070305, 071148, 073134, 031923, 051438, 067320, 067632,067692.
(photographs attached : Yes

GSM CO., LTD.