CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Lateral Force for One-Story Wall Based on ASCE 7-16 & 2018 IBC
INPUT DATA
WALL THICKNESS t = 8 in, (203 mm)
PARAPET HEIGHT hp = 4 ft, (1.2 m)
WALL HEIGHT h = 14 ft, (4.3 m)
TOTAL WALL DENSITY r= 150 lbs/ft3 ( 2401 kg/m3)
SEISMIC PARAMETER SDS = 0.54 (ASCE 7 Sec 11.4)
SEISMIC DESIGN CATEGORY SDC = C
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes) 1 Yes
SEISMIC IMPORTANCE FACTOR Ie = 1 (ASCE 7 Tab 11.5-1)
WIND IMPORTANCE FACTOR Iw = 1.0 (ASCE 7 Tab 1.5-2)
BASIC WIND SPEED V= 112 mph, (180 kph), (ASCE 7 Sec 26.5.1)
EXPOSURE CATEGORY (B, C, D) = C
TOPOGRAPHIC FACTOR KZt = 1 Flat, (ASCE 7 Tab 26.8-1)
DESIGN SUMMARY
Out-of-plane force for wall design w1 = 20.9 psf (Wind governs) , ( 1001 N/m2)
Out-of-plane force for parapet design w2 = 63.1 psf (Wind governs) , ( 3023 N/m2)
Out-of-plane force for anchorage design Fanch = 435 plf (Horizontal direction) , ( 6343 N/m)
(The governing seismic & wind forces have been reduced by 0.7 & 0.6 for ASD)
WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-16 Eq. 30.3-1)
h hp
F anch ,wind w1, wind h p 1 w 2, wind
2 2h = 435 plf (Horizontal)
SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7, Sec.12.11.1)
w1, seismic MAX 0.4 I S DSW p , 0.1W p
= 0.22 Wp = 21.6 psf
h h p h h p
2 2
For seismic design category C and above, flexible diaphragm (ASCE 7 Sec. 12.11.2.1)
h h p hh p
2 2
1.2a p S DS I p
F anch , seismic MAX MAX 0.4 S DS I p , MIN , 1.6 S DS I p W p , 400 S DS I , F min
Rp 2h
INPUT DATA
WALL THICKNESS t = 8 in
PARAPET HEIGHT hp = 4 ft
WALL HEIGHT h = 14 ft
TOTAL WALL DENSITY r = 150 pcf
SEISMIC PARAMETER SDS = 0.54 (ASCE 7-05 Sec 11.4.4)
SEISMIC DESIGN CATEGORY SDC = C
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes) 1 Yes
SEISMIC IMPORTANCE FACTOR I = 1 (ASCE 7-05 Tab 11.5-1)
WIND IMPORTANCE FACTOR I = 1 (ASCE 7-05 Tab 6-1)
BASIC WIND SPEED V = 90 mph
EXPOSURE CATEGORY (B, C, D) = C
TOPOGRAPHIC FACTOR KZt = 1 Flat, (ASCE 6.5.7.2)
DESIGN SUMMARY
Out-of-plane force for wall design w1 = 22.5 psf (Wind governs)
Out-of-plane force for parapet design w2 = 61.7 psf (Wind governs)
Out-of-plane force for anchorage design Fanch = 440 plf (Horizontal direction)
(The governing seismic forces have been reduced by 0.7 for ASD)
WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-05, Eq.6-22)
h hp
F anch , wind w1, wind h p 1 w 2, wind
2h
= 440 plf (Horizontal)
2
SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7-05, Sec.12.11.1)
Out-of-plane seismic force for parapet design (ASCE 7-05, Sec. 13.3.1)
1.2a p S DS I pW p 0.65 Wp =
w 2, seismic MAX 0.3S DS I pW p , MIN
= 64.8 psf
, 1.6 S DS I pW p
Rp
Where : ap = 2.5 , Ip = 1.0 , Rp = 2.5
(ASCE Tab. 13.5-1) (ASCE Sec. 13.1.3) (ASCE Tab. 13.5-1)
hh p
2 2
h h p
F anch ,seismic MAX 0.4 S DS I W p , 0.1W p , 400S DS I , F min 2.80 Wp =
2h 2h
280 plf (Horizontal)
(Not applicable)
Where : Fmin = 280 plf
(ASCE Sec. 12.11.2 & 11.7.3)
For seismic design category C and above, flexible diaphragm (ASCE 7-05 Sec. 12.11.2.1)
hh p
2 2
h h p
, 400S DS I , F min
F anch , seismic MAX 0.8S DS I W p , 0.1W p
5.00 Wp =
2h 2h 500 plf (Horizontal)
(Applicable)
For seismic design category C and above, rigid diaphragm (ASCE 7-05 Sec. 12.11.2 & Sec. 13.3.1)
h h p
2
1.2a p S DS I p
F anch ,seismic MAX MAX 0.3S DS I p , MIN , 1.6 S DS I p W p , 400 S DSI , F min
R p 2h
= 5.00 W = 500 plf (Horizontal)
p (Not applicable)
Where : ap = 1.0 Rp = 1.5