Вы находитесь на странице: 1из 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Lateral Force for One-Story Wall Based on ASCE 7-16 & 2018 IBC

INPUT DATA
WALL THICKNESS t = 8 in, (203 mm)
PARAPET HEIGHT hp = 4 ft, (1.2 m)
WALL HEIGHT h = 14 ft, (4.3 m)
TOTAL WALL DENSITY r= 150 lbs/ft3 ( 2401 kg/m3)
SEISMIC PARAMETER SDS = 0.54 (ASCE 7 Sec 11.4)
SEISMIC DESIGN CATEGORY SDC = C
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes) 1 Yes
SEISMIC IMPORTANCE FACTOR Ie = 1 (ASCE 7 Tab 11.5-1)
WIND IMPORTANCE FACTOR Iw = 1.0 (ASCE 7 Tab 1.5-2)
BASIC WIND SPEED V= 112 mph, (180 kph), (ASCE 7 Sec 26.5.1)
EXPOSURE CATEGORY (B, C, D) = C
TOPOGRAPHIC FACTOR KZt = 1 Flat, (ASCE 7 Tab 26.8-1)

DESIGN SUMMARY
Out-of-plane force for wall design w1 = 20.9 psf (Wind governs) , ( 1001 N/m2)
Out-of-plane force for parapet design w2 = 63.1 psf (Wind governs) , ( 3023 N/m2)
Out-of-plane force for anchorage design Fanch = 435 plf (Horizontal direction) , ( 6343 N/m)
(The governing seismic & wind forces have been reduced by 0.7 & 0.6 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-16 Eq. 30.3-1)

w1, wind  0.6q h  GC P    GC Pi     0.00256 K h K Zt K d K eV    G C P    GC Pi  


2
= 20.9 psf

Where : Kh = 0.86 , Kd = 0.85 , GCp = -1.30 , GCpi = 0.18


(mean roof h = 16 ft, changeable) Ke = 1.00 (corner ? Yes , TA = 18.667 ft2 ) (ASCE 7-16 Tab. 26.13-1)
(ASCE 7-16 26.10-1) (ASCE 7-16 30.3.2)
Out-of-plane wind force for parapet design (ASCE 7-16 Eq. 30.8-1)

w 2,wind  0.6q p  G C P    GC Pi     0.00256 K h K Zt K d K eV    G C P    G C Pi  


2
= 63.1 psf, (ASCE 7-16 30.8)

Where : Kh = 0.88 , Kd = 0.85 , GCp = -1.40 , GCp = -3.20 GCpi = 0.18


(ASCE 7-16 26.10-1) (ASCE 7-16 26.10-1) = 1.00 roof, (ASCE 7-16 30.3.2) ( ASCE 7-16 Tab. 26.13-1)
(TA = 5.3333 ft2 )
wall, (ASCE 7-16 30.3.2)
Out-of-plane wind force for anchorage design

h  hp 
F anch ,wind  w1, wind  h p  1  w 2, wind
2  2h  = 435 plf (Horizontal)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7, Sec.12.11.1)
w1, seismic  MAX  0.4 I S DSW p , 0.1W p 
= 0.22 Wp = 21.6 psf

Where : Wp = 100.0 psf , Ie = 1.0


(CBC/IBC Tab 1604.5 & ASCE 7 Tab 1.5-2)

Out-of-plane seismic force for parapet design (ASCE 7, Sec. 13.3.1)


  1.2a p S DS I pW 
w 2,seismic  MAX  0.3S DS I pW
p
p , MIN  , 1.6 S DS I pW p  
= 0.65 Wp = 64.8 psf
  Rp  

Where : ap = 2.5 , Ip = 1.0 , Rp = 2.5


(ASCE 7 Tab. 13.5-1) (ASCE 7 Sec. 13.1.3) (ASCE 7 Tab. 13.5-1)

Out-of-plane seismic force for anchorage design


For masonry or concrete under seismic design category A & B, both flexible & rigid diaphragm (ASCE 7 Sec. 12.11.2)


 h h p   h h p  
2 2

F anch , seismic  MAX  0.4 S DS IW , 0.1W , 400 S DS I , F min  


 p
2h
p
2h  2.80 Wp =
  280 plf (Horizontal)
(Not applicable)
Where : Fmin = 280 plf
(ASCE 7 Sec. 12.11.2 & 11.7.3)

For seismic design category C and above, flexible diaphragm (ASCE 7 Sec. 12.11.2.1)

 h h p   hh p  
2 2

F anch , seismic  MAX  0.8S DS I W , 0.1W , 400 S DSI , F min  


 p
2h
p
2h  5.00 Wp =
  500 plf (Horizontal)
(Applicable)
For seismic design category C and above, rigid diaphragm (ASCE 7 Sec. 12.11.2 & Sec. 13.3.1)

 h h p  
2

   1.2a p S DS I p  
F anch , seismic  MAX  MAX  0.4 S DS I p , MIN  , 1.6 S DS I p   W p , 400 S DS I , F min 
   Rp   2h 
 

= 5.00 Wp = 500 plf (Horizontal) (Not applicable)


Where : ap = 1.0 Rp = 1.5
(ASCE 7 Tab. 13.5-1) (1.5, ASCE 7 13.4.2 or 2.5, ASCE 7 Tab 13.5-1)
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Lateral Force for One-Story Wall Based on 2009 IBC

INPUT DATA
WALL THICKNESS t = 8 in
PARAPET HEIGHT hp = 4 ft
WALL HEIGHT h = 14 ft
TOTAL WALL DENSITY r = 150 pcf
SEISMIC PARAMETER SDS = 0.54 (ASCE 7-05 Sec 11.4.4)
SEISMIC DESIGN CATEGORY SDC = C
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes) 1 Yes
SEISMIC IMPORTANCE FACTOR I = 1 (ASCE 7-05 Tab 11.5-1)
WIND IMPORTANCE FACTOR I = 1 (ASCE 7-05 Tab 6-1)
BASIC WIND SPEED V = 90 mph
EXPOSURE CATEGORY (B, C, D) = C
TOPOGRAPHIC FACTOR KZt = 1 Flat, (ASCE 6.5.7.2)

DESIGN SUMMARY
Out-of-plane force for wall design w1 = 22.5 psf (Wind governs)
Out-of-plane force for parapet design w2 = 61.7 psf (Wind governs)
Out-of-plane force for anchorage design Fanch = 440 plf (Horizontal direction)
(The governing seismic forces have been reduced by 0.7 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-05, Eq.6-22)

w1, wind  q h  GC P    GC Pi     0.00256 K h K Zt K dV I    GC P    G C Pi  


2 = 22.5 psf

Where : Kh = 0.86 , Kd = 0.85 , GCp = -1.30 , GCpi = 0.18


(mean roof h = 16 ft, changeable) (ASCE Tab. 6-4) (corner ? Yes , TA = 18.667 ft2 ) (ASCE Fig. 6-5)
(ASCE Tab. 6-3) (ASCE Fig. 6-11A)
Out-of-plane wind force for parapet design (ASCE 7-05, Eq.6-24)

w 2, wind  q p  GC P    GC Pi     0.00256 K h K Zt K dV I w    G C P    G C Pi  


2
= 61.7 psf, (ASCE 7-05,6.5.12.4.4)

Where : Kh = 0.88 , Kd = 0.85 , GCp = -1.40 , GCp = -2.80 GCpi = 0.18


(ASCE Tab. 6-3) (ASCE Tab. 6-4) = 1.00 (roof, ASCE Fig. 6-11B) (roof, ASCE Fig. 6-5)
(TA = 5.3333 ft2 )
(wall, ASCE Fig. 6-11A)
Out-of-plane wind force for anchorage design

h  hp 
F anch , wind  w1, wind  h p  1  w 2, wind
2h 
= 440 plf (Horizontal)
2 

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7-05, Sec.12.11.1)

w1, seismic  MAX  0.4 I S DSW p , 0.1W p  = 0.22 Wp = 21.6 psf

Where : Wp = 100.0 psf , I = 1.0


(IBC Tab 1604.5 & ASCE Tab 11.5-1)

Out-of-plane seismic force for parapet design (ASCE 7-05, Sec. 13.3.1)

  1.2a p S DS I pW p  0.65 Wp =
w 2, seismic  MAX  0.3S DS I pW p , MIN 
= 64.8 psf
, 1.6 S DS I pW p 
  Rp 
Where : ap = 2.5 , Ip = 1.0 , Rp = 2.5
(ASCE Tab. 13.5-1) (ASCE Sec. 13.1.3) (ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design


For masonry or concrete under seismic design category A & B, both flexible & rigid diaphragm (ASCE 7-05 Sec. 12.11.2)


   hh p  
2 2
h h p
F anch ,seismic  MAX  0.4 S DS I W p , 0.1W p , 400S DS I , F min   2.80 Wp =
 2h 2h 
  280 plf (Horizontal)
(Not applicable)
Where : Fmin = 280 plf
(ASCE Sec. 12.11.2 & 11.7.3)

For seismic design category C and above, flexible diaphragm (ASCE 7-05 Sec. 12.11.2.1)


   hh p  
2 2
h h p
 , 400S DS I , F min  
F anch , seismic  MAX  0.8S DS I W p , 0.1W p

5.00 Wp =
2h 2h 500 plf (Horizontal)
  (Applicable)
For seismic design category C and above, rigid diaphragm (ASCE 7-05 Sec. 12.11.2 & Sec. 13.3.1)


 h h p  
2

   1.2a p S DS I p  
F anch ,seismic  MAX  MAX  0.3S DS I p , MIN  , 1.6 S DS I p   W p , 400 S DSI , F min
   R p   2h 
 
= 5.00 W = 500 plf (Horizontal)
p (Not applicable)
Where : ap = 1.0 Rp = 1.5
(ASCE Tab. 13.5-1) (1.5, ASCE 13.4.2 or 2.5, ASCE Tab 13.5-1)