Вы находитесь на странице: 1из 4

TECHNICAL SPECIFICATION:

1) Filter Feed Pump with motor 1 Nos


Make : Kirloskar/Equivalent
Type : Monobloc, Self Primming
Flow : 3m3/hr
MOC : Cast Iron
Head : 35 MWC
Rating : 1HP

2) Pressure Sand Filter 1 Nos


Make : PENTAIR/Equivalent
Tank Type : FRP
Medias : Pebbles, Sand
Size : 13 x 54”
Op Pressure : 3 kg/cm2

3) Activated Carbon Filter 1 Nos


Make : PENTAIR/Equivalent
Tank Type : FRP
Medias : Pebbles, Sand, Activated Carbon
Size : 13 x 54”
Op Pressure : 3 kg/cm2

4) Cartridge Filter with Housing 1 Set


Make : HT COMMA/Equivalent
Cartridge Size : 5 Micron, 20” long
Housing Size : 100 x 600mm

5) Dosing Pump 2 Nos


Make : GES
Range : 0-6 LPH
6) High Pressure Pump with motor 1 Nos
Make : Grundfos/Equivalent
Type : Vertical centrifugal pump
Pressure : 13.5 kg/cm2
Head : 135 M

7) Membrane 4 Nos
Make : Filmtec/Equivalent
Model No : 4040
Type : Spiral Wound
Size : 8 Inch
MOC : Thin Film Composite

8) Pressure Vessel 2 Nos


Make : Pentair/Equivalent
Size : 4 Inch (D)
Vessel Length : 80 Inch
Pressure : 250 PSI

9) U.V. System 1 No
Flow Rate 1,000 Ltrs. /Hr.
Material of Construction Stainless Steel 304
No. U.V. Lamps & Power 1 x 39 watts
No. of Cylinders 1
No. of Quartz Jackets 1
Inlet/Outlet Pipe Size 1"
Life of the Lamp 7500 Hrs.

10) Accessories

1. Flow meter (Rota meter)


M.O.C : PC
Range : 300-3000 LPH
Nos. offered : 2 Nos

2. Pressure Gauges : 3Nos


Type : Panel Mountable
Size : 2.5” SS Glycerin filled
Qty : 3 nos

3. Internal pipe and valve


Moc : SS304/CPVC
Valve sizes : 15NB and 25NB
Valve Qty : 4nos

CONTROL PANEL SYSTEM:

The RO skid shall be supplied with a control panel with the following features :
1. Starter switch for high pressure pumps motor.
2. On/Off switch with indication for high pressure pump.
3. Low Pressure Switch.
4. Feed, Reject Pressure Gauge.
5. Reject Control Valve.
6. Permeate, reject flow meter.
7. Relays and required electrical components.
8. Powder coated panel board.

Note: The above all systems required following


1. Anti scalant should be silica or Phosphate based depends on raw water quality.
2. permeate flush @ before shut down the system
3. If possible coagulant can be added in Raw water
4. Without anti scalant system should not Run
5. Rejection flow should be as per system design
6. This Design applicable only if the TDS<1500ppm,
SDI<3,Hardness<300ppm,BOD<30ppm & COD<80ppm,System recovery 40 –
50%

CLIENT SCOPE:
 All Civil Works like Pump Foundations, Raw water storage tank,
Permeate water storage tank, Reject water storage tank.
 Adequate Room for RO Plant with Electricity.
 Pipeline from raw water area to plant area.
 Pipeline from plant area to Drinking water storage tank.
 3 phase supply point at plant area.