FIRMWARE HISTORY

06/06/2018

PRODUCT CODE: M022/M024/M026/M028


APPLICABLE MODEL:
LANIER – LD130C/LD130C SR/LD140C/LD140CSR
RICOH – AFICIO MP C300/MP C300SR/MP C400/MP C400SR
SAVIN – C230/C230SR/C240/C240SR

GENERAL:
The latest firmware version can be downloaded at either the Technology Solutions Resource Center web site at
http://www.tsrc.ricoh-usa.com/rolocpfm/mpc300.asp or FSD/DSD. Please obtain the latest firmware from the
appropriate location as needed and be sure to check the README file for important notes and explanations.

Revised items appear in bold typeface.

TABLE OF CONTENTS:

1. ENGINE FIRMWARE ver. 1.03:02: ...................................................... 2


2. SYSTEM/COPY FIRMWARE ver. 2.11: .............................................. 3
3. PRINTER FIRMWARE ver. 1.01: ......................................................... 7
4. SCANNER FIRMWARE ver. 01.06: .................................................... 8
5. WEB SUPPORT FIRMWARE ver. 1.04:.............................................. 9
6. WEB UAPL FIRMWARE ver. 1.01: .................................................... 11
7. REMOTE FAX FIRMWARE ver. 01.00.00: ......................................... 12
8. RPCS FIRMWARE ver. 3.10.14: ........................................................ 13
9. PS3/PDF FIRMWARE ver. 1.01: ........................................................ 14
10. PCL FIRMWARE ver. 1.11:.............................................................. 15
11. PICTBRDG FIRMWARE ver. 1.09.04: ............................................. 17
12. OPE PANEL FIRMWARE ver. 1.04:................................................. 18
13. NETWORK DOCBOX FIRMWARE ver. 1.05: .................................. 19
14. NETWORK SUPPORT FIRMWARE ver. 10.60:.............................. 20
15. MEDIAPRINT FIRMWARE ver. 1.01.00: .......................................... 23
16. LANGUAGE INSTALL FIRMWARE ver. 1.04:.................................. 24
17. FAX FIRMWARE ver. 04.00.00: ....................................................... 25
18. POWERSAVING SYSTEM FIRMWARE ver. F.17: .......................... 26
19. FCU (WW) FIRMWARE ver. 05.00.00: ............................................ 27
20. FINISHER FIRMWARE ver. 01.030:08: ........................................... 28
21. ADF FIRMWARE ver. 01.030:04:..................................................... 29

NOTE: For Java VM 7 information see JAVA VM v7 Firmware History (RFG- 054274).

Copyright  2016 RICOH Americas Corporation. All rights reserved. Page 1 of 29


Firmware History for M022/M024/M026/M028

1. ENGINE FIRMWARE ver. 1.03:02:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.01:02 M0265501C 1st Mass Production
1.02:02 M0265501D February 2011 Production
1.03:02 M0265501E September 2013 Production

1.1 ENGINE FIRMWARE HISTORY:


FIRMWARE
ENGINE FIRMWARE
VERSION
Initial Production Release 1.01:02
Corrects the following: 1.02:02
 Minor bug corrections.
Corrects the following: 1.03:02
 SC240/241 occurs when the machine has been initialized or recovered from energy-
saving mode.

Page 2 of 29
Firmware History for M022/M024/M026/M028

2. SYSTEM/COPY FIRMWARE ver. 2.11:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.02.1 M0265771D 1st Mass Production
1.03 M0265771E December 2010
1.04 M0265771F March 2011
2.00 M0265771G May 2011
2.01 M0265771H July 2011
2.02 M0265771J November 2011
2.05 M0265771M April 2012
2.06 M0265771N June 2012
2.07 M0265771P April 2013
2.08 M0265771Q September 2013
2.09 M0265771R February 2014
2.10 M0265771S June 2015
2.11 M0265771T May 2018

Page 3 of 29
Firmware History for M022/M024/M026/M028

2.1 SYSTEM/COPY FIRMWARE HISTORY:


FIRMWARE
SYSTEM/COPY FIRMWARE HISTORY
VERSION
Initial Production Release 1.02.1
Corrects the following: 1.03
 Users that are not registered in the address book cannot copy or print when the "Quota
Setting" function is enabled, even if they have not reached their limit. This only occurred if
Windows, LDAP or SDK Custom authentication was used to authenticate the user.
 Users can exceed their limit for the number of pages they can copy as configured by the
"Print Volume Use Limitation" setting. This could occur if "Machine Action when Limit is
reached" = "Stop job", and if any of the device's network settings were changed via telnet
while the Copier was being used.
 When an SC error occurs, the illustration for a different model is displayed.
Corrects the following: 1.04
 Stored jobs (Locked Print, Sample Print, etc.) might not be shown in the operation panel if
the DataOverwriteSecurity Unit is installed.
 Use of the "Preview" function with Scan to Folder or Scan to E-mail might result in the
MFP stalling and/or an SC997 error.
 The pressing of a button in very specific types of SDK applications could result in the
MFP stalling.
 Scanned pages will not be accurately counted by the User Code Counter if both of the
following conditions are met.
- Scan Settings = Auto Color Select
- The document contains a mix of BW and color pages.
 After the MFP enters Energy Saver mode, the USB host ports will no longer work until the
device is rebooted.
 SC819 occurs when an SDK/J (Type 2) application is installed from an administrative
server.
 SC819 occurs during HDD initialization.
Other changes:
 Supports the Common Criteria (CC) certified Data Overwrite Security System (DOSS).
 Note: With all previous System/Copy firmware (versions earlier than v1.04), an error will
result if the CC certified DOSS is installed.
…continued

Page 4 of 29
Firmware History for M022/M024/M026/M028

FIRMWARE
SYSTEM/COPY FIRMWARE HISTORY
VERSION
Corrects the following: 2.00
 Cannot move the HDD Encryption option to another SD card.
 The SP Mode key does not work when pressed during a copy job.
Other changes:
 Support for the Bluetooth option (USB dongle) has been added.
Corrects the following: 2.01
 Enabling of 'User Code Auth. > Printer > PC Control' results in accounts created
automatically upon submission of a job being given no permission to any device
functionality.
Corrects the following: 2.02
 Minor bug corrections.
Corrects the following: 2.05
 If Basic Authentication was enabled and either "Restrict Use of Destination" or "Restrict
Adding of User Destinations" were on, users were unable to access the addressbook
even to change their own password. After the change, users will be able to change their
passwords.
 The MFP's password policy can now be changed even when an external server is used
for authentication.
Corrects the following: 2.06
 The heap and stack sizes for SDK applications appear at their default values on the
SMC, even after these settings are changed.
 A "Home" button appears on the Copier screen after the machine warms up (even though
there is no function that corresponds to this button).
 An SC899 might occur when an "Extended Feature" is started manually via WIM.
 If the "External Optional Counter Type" setting (SP-5113-002) is not equal to '0', the
following problems might occur:
 Print jobs result in the Data-In LED blinking but nothing is output.
 Fax jobs are printed successfully but not counted by the counter.
 If "Security Settings for Access Violation" is "On", the following two problems will occur:
- Users' print volumes are not counted.
- The "used" and "maximum" print volumes are not displayed on the operation panel.
 The timer used for the "Access Violation" setting's time interval does not properly
compensate for changes to the device timer.
Other changes:
 Supports copying and scanning of mixed letter and legal sized originals ("LT/LG Mixed
Sizes").
IMPORTANT: To use this feature, make sure that the following firmware versions or
newer are also installed.
System/Copy: ver. 2.06 (M0265771N)
Scanner: ver. 1.05 (M0265777D)
…continued

Page 5 of 29
Firmware History for M022/M024/M026/M028

FIRMWARE
SYSTEM/COPY FIRMWARE HISTORY
VERSION
Corrects the following: 2.07
 An incorrect error message is displayed when the operator switches from exposure glass
to ADF copy mode.
("Please set 8 1/2 x 14" or "Please set "8 1/2 x 11").
- If User Code authentication is enabled or if "External Optional Counter Type”! = 0,
accounts locked by the "Lock out" setting (SP-5413-1) are not locked out of WIM.
- Although the "Logout Using Card" function of Card Authentication Package v2 is turned
on, the user cannot log out when he or she swipes the card.
- Even though the Restrict Use of Destinations (Scanner) setting is set to ON, email
addresses that are found by an LDAP Search are still editable by end-users.
- Cannot scan to shared folders in Mac OS X 10.7 or Mac OS X 10.8.
 This firmware is dependent on the following firmware modules. Please be sure to update
all of them:
Network Support firmware v10.59 or later
Specification change: 2.08
 Compliant with Blue Angel regulations.
Corrects the following: 2.09
 The time correction for Summer Time (Southern Hemisphere) is not applied after the
setting is enabled.
 [Embedded RC Gate]: @Remote auto calls (Ex. service calls, supply calls, alarm calls)
are not sent from the device if engine-related SC errors occur frequently within a short
period of time.
Corrects the following: 2.10
 SC867 may occur if an SDK application is (already) installed on the machine.
Other changes: 2.11
 Newly added SMBv2/v3 support.
 This firmware is dependent on the following firmware modules. Please be sure to
update all of them:
 System/Copy v2.11 (M0265771T)
 Network Support v10.60 (M0265792L)
 Web Support v1.04 (M0265788F)
 Scanner v01.06 (M0265777E)

Page 6 of 29
Firmware History for M022/M024/M026/M028

3. PRINTER FIRMWARE ver. 1.01:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.00 M0265794B 1st Mass Production
1.01 M0265794B March 2011 Production

3.1 PRINTER FIRMWARE HISTORY:


FIRMWARE
PRINTER FIRMWARE
VERSION
Initial Production Release 1.00
Other changes: 1.01
 A new BitSwitch#9-4 has been added. When set to '1', if multiple collated copies are
printed, the device no longer responds to PJL USTATUS with the number of pages in the
current copy. Instead the device will return the total number of pages for all copies.
Corrects the following:
 Batches of jobs being printed from the device hard disk (Locked Print jobs for example)
might be interrupted by Normal Print jobs.

Page 7 of 29
Firmware History for M022/M024/M026/M028

4. SCANNER FIRMWARE ver. 01.06:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
01.03 M0265777B 1st Mass Production
01.04 M0265777C November 2011
01.05 M0265777D June 2012
01.06 M0265777E May 2018

4.1 SCANNER FIRMWARE HISTORY:


FIRMWARE
SCANNER FIRMWARE
VERSION
Initial Production Release 01.03
Other changes: 01.04
 Scan to file would not allow the creation of PDF files if the "Master Password" setting was
configured but the "Document Password" setting was not. After the fix, Scan to file will
now allow the creation of PDF files under these conditions.
This firmware is dependent on the following firmware modules.
Please be sure to update all of them:

Network DocBox Ver. 1.03 (M0265793C)


Scanner Ver. 01.04 (M0265777C)
Web Uapl Ver. 1.01 (M0265789C)
Other changes: 01.05
 Supports copying and scanning of mixed letter and legal sized originals ("LT/LG Mixed
Sizes").

IMPORTANT: To use this feature, make sure that the following firmware versions or
newer are also installed.
System/Copy: ver. 2.06 (M0265771N)
Scanner: ver. 1.05 (M0265777D)

Page 8 of 29
Firmware History for M022/M024/M026/M028

5. WEB SUPPORT FIRMWARE ver. 1.04:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.00.1 M0265788B 1st Mass Production
1.01 M0265788C March 2011
1.02 M0265788D April 2012
1.03 M0265788E September 2013
1.04 M0265788F May 2018

Page 9 of 29
Firmware History for M022/M024/M026/M028

5.1 WEB SUPPORT FIRMWARE HISTORY:


FIRMWARE
WEB SUPPORT FIRMWARE
VERSION
Initial Production Release 1.00.1
Other changes: 1.01
SSL-related changes:

NOTE: The new fields will only appear if Network Support firmware version 10.53 or later
has also been applied to the device.
 When the device creates a certificate request, it is now able to specify which algorithm
(SHA1 or MD5) it wants used to sign the certificate. This has been implemented by
adding a field "Algorithm Signature" to the certificate request form.
 Web Image Monitor now shows the certificate's key length in:
- Configuration > Security > Device Certificate > Details
 Specific versions of SSL or TLS (SSLv2, SSLv3, or TLSv1) can now be enabled/disabled
using Web Image Monitor. The setting can be configured from either of the following
locations:
- Configuration > Security > Network Security
- Configuration > Security > SSL/TLS
 The encryption strength used for SSL can now be configured. This can be done using
either of the following settings in Web Image Monitor:
- Configuration > Security > Network Security
- Configuration > Security > SSL/TLS
Other changes: 1.02
 Users can now change their passwords for Basic Authentication using Web ImageMonitor
if the following conditions are met:
- Basic Authentication is enabled.
- Either of the following device settings is enabled
- User Tools/Counter > System Settings > Administrator Tools > Extended Security >
Restrict Use of Destinations
- User Tools/Counter > System Settings > Administrator Tools > Extended Security >
Restrict Adding of User Destinations
Other changes: 1.03
 When using the web development tools like Firebug in Web Image Monitor users who do
not have the authority of editing might even be able to edit the administrative privileges of
each.
Other changes: 1.04
 Newly added SMBv2/v3 support.
 This firmware is dependent on the following firmware modules. Please be sure to
update all of them:
 System/Copy v2.11 (M0265771T)
 Network Support v10.60 (M0265792L)
 Web Support v1.04 (M0265788F)
 Scanner v01.06 (M0265777E)

Page 10 of 29
Firmware History for M022/M024/M026/M028

6. WEB UAPL FIRMWARE ver. 1.01:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.00.1 M0265789B 1st Mass Production
1.01 M0265789C November 2011 Production

6.1 WEB UAPL FIRMWARE HISTORY:


FIRMWARE
WEB UAPL FIRMWARE
VERSION
Initial Production Release 1.00.1
Other changes: 1.01
 Scan to file would not allow the creation of PDF files if the "Master Password" setting was
configured but the "Document Password" setting was not. After the fix, Scan to file will
now allow the creation of PDF files under these conditions.
This firmware is dependent on the following firmware modules.
Please be sure to update all of them:
Network DocBox Ver. 1.03 (M0265793C)
Scanner Ver. 01.04 (M0265777C)
Web Uapl Ver. 1.01 (M0265789C)

Page 11 of 29
Firmware History for M022/M024/M026/M028

7. REMOTE FAX FIRMWARE ver. 01.00.00:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
01.00.00 M0265775B 1st Mass Production

7.1 REMOTE FAX FIRMWARE HISTORY:


FIRMWARE
REMOTE FAX FIRMWARE
VERSION
Initial Production Release 01.00.00

Page 12 of 29
Firmware History for M022/M024/M026/M028

8. RPCS FIRMWARE ver. 3.10.14:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
3.10.14 M0265795 1st Mass Production

8.1 RPCS FIRMWARE HISTORY:


FIRMWARE
RPCS FIRMWARE
VERSION
Initial Production Release 3.10.14

Page 13 of 29
Firmware History for M022/M024/M026/M028

9. PS3/PDF FIRMWARE ver. 1.01:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.00 M0265797A 1st Mass Production
1.01 M0265797B October 2011 Production

9.1 PS3/PDF FIRMWARE HISTORY:


FIRMWARE
PS3/PDF FIRMWARE
VERSION
Initial Production Release 1.00
Corrects the following: 1.01
 PDF Direct jobs containing a mask that was created using tiling will be reset.

Page 14 of 29
Firmware History for M022/M024/M026/M028

10. PCL FIRMWARE ver. 1.11:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.03 M0265796B 1st Mass Production
1.04 M0265796C March 2011
1.05 M0265796D July 2011
1.06 M0265796E November 2011
1.07 M0265796F March 2012
1.08 M0265796G December 2012
1.09 M0265796H March 2013
1.10 M0265796J September 2013
1.11 M0265796K January 2015

10.1 PCL FIRMWARE HISTORY:


FIRMWARE
PCL FIRMWARE
VERSION
Initial Production Release 1.03
Corrects the following: 1.04
 The color of objects in a PCL5 macro might not have been assigned a color, resulting in
them being the same color as the background. This made them invisible.
 The wrong font might be used in PCL5 jobs containing PCL5 macros. This could result in
text appearing differently than expected.
Other Changes 1.05
 Objects out of position in PCL5 jobs containing HP-GL/2 and Macro.
Other Changes 1.06
 Shifted characters in duplex PCL jobs containing macro that use either of the following
commands:
<ESC>&I#U
<ESC>&I#Z
Corrects the following: 1.07
 SC899 caused by the printing of specific kinds of scalable True Type fonts.
Corrects the following: 1.08
 The use of a PCL5 macro results in an extra blank page being added to the job.
 PCL6 jobs containing raster images and submitted using an Office 2010 application,
cause the device to throw an SC899. This only occurred if the "Enable Large Papers"
setting was disabled.
 SC899 caused by the printing of specific kinds of TrueType fonts in PCL jobs.
Corrects the following: 1.09
 Characters or symbols missing from the printouts of PCL5 jobs containing HP-GL/2.
Corrects the following: 1.10
 Additional condition that caused “SC899 caused by the printing of specific kinds of
TrueType fonts in PCL jobs” to still occur after the release of v1.09.
…continued

Page 15 of 29
Firmware History for M022/M024/M026/M028

FIRMWARE
PCL FIRMWARE
VERSION
Corrects the following: 1.11
 A PCL XL error might occur when using the Citrix UPD to print.
 If the glyph data of TrueType fonts includes hinting information that is on the edge of the
frame, an SC899 error might occur.
…continued

Page 16 of 29
Firmware History for M022/M024/M026/M028

11. PICTBRDG FIRMWARE ver. 1.09.04:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.09.04 M0265776 1st Mass Production

11.1 PICTBRDG FIRMWARE HISTORY:


FIRMWARE
PICTBRDG FIRMWARE
VERSION
Initial Production Release 1.09.04

Page 17 of 29
Firmware History for M022/M024/M026/M028

12. OPE PANEL FIRMWARE ver. 1.04:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.02 M0261492C 1st Mass Production
1.03 M0261492D March 2012 Production
1.04 M0261492E June 2012 Production

12.1 OPE PANEL FIRMWARE HISTORY:


FIRMWARE
OPE PANEL FIRMWARE
VERSION
Initial Production Release 1.02
Other changes: 1.03
 A software button was added to the Copier screen, which can be assigned to specific
SDK applications.
Note: In order to utilize this change, the SDK application itself must also support this
functionality. For details, see the Release Notes for each application (TBA).
 A cautionary message will be displayed while the machine is performing the encryption of
the hard disk (equivalent to "Do not turn off the power while the encryption is in
progress").
Corrects the following: 1.04
 Minor bug correction.

Page 18 of 29
Firmware History for M022/M024/M026/M028

13. NETWORK DOCBOX FIRMWARE ver. 1.05:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.02 M0265793B 1st Mass Production
1.03 M0265793C November 2011 Production
1.04 M0265793D March 2012 Production
1.05 M0265793E June 2012 Production

13.1 NETWORK DOCBOX FIRMWARE HISTORY:


FIRMWARE
NETWORK DOCBOX FIRMWARE
VERSION
Initial Production Release 1.02
Other changes: 1.03
 Scan to file would not allow the creation of PDF files if the “Master Password” setting was
configured but the “Document Password” setting was not. After the fix, Scan to file will
now allow the creation of PDF files under these conditions.
This firmware is dependent on the following firmware modules.
Please be sure to update all of them:
Network DocBox Ver. 1.03 (M0265793C)
Scanner Ver. 01.04 (M0265777C)
Web Uapl Ver. 1.01 (M0265789C)
Corrects the following: 1.04
 Minor bug correction.
Corrects the following: 1.05
 The captured user name might be garbled. This occurs if User Administrator
Authentication is enabled and if the user's "Key Display" setting is 16 byte in length.

Page 19 of 29
Firmware History for M022/M024/M026/M028

14. NETWORK SUPPORT FIRMWARE ver. 10.60:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
10.51 M0265792B 1st Mass Production
10.52 M0265792C December 2010
10.53 M0265792D March 2011
10.54 M0265792E May 2011
10.55 M0265792F July 2011
10.56 M0265792G November 2011
10.57 M0265792H March 2012
10.58 M0265792J June 2012
10.59 M0265792K April 2013
10.60 M0265792L May 2018

Page 20 of 29
Firmware History for M022/M024/M026/M028

14.1 NETWORK FIRMWARE HISTORY:


FIRMWARE
NETWORK FIRMWARE
VERSION
Initial Production Release 10.51
Corrects the following: 10.52
 Scan to SMB fails if the file submitted to the DFS folder in the destination and the file of
the same name exist in the DFS folder.
 If Windows Authentication is enabled, printing a large number of copies of a job might
take longer than might typically be expected.
SSL-related changes: 10.53

NOTE: The new field will only appear if Web Support firmware version 1.01 or later has
also been applied to the device.
 When the device creates a certificate request, it is now able to specify which algorithm
(SHA1 or MD5) it wants used to sign the certificate. This has been implemented by
adding a field "Algorithm Signature" to the certificate request form.
 Web Image Monitor now shows the certificate's key length in:
- Configuration > Security > Device Certificate > Details
 Specific versions of SSL or TLS (SSLv2, SSLv3, or TLSv1) can now be enabled/disabled
using Web Image Monitor. The setting can be configured from either of the following
locations:
- Configuration > Security > Network Security
- Configuration > Security > SSL/TLS
 The encryption strength used for SSL can now be configured. This can be done using
either of the following settings in Web Image Monitor:
- Configuration > Security > Network Security
- Configuration > Security > SSL/TLS
------------------------
 For security reasons, the device will no longer accept SSL incoming, or establish
outgoing, connections that use NULL or ADH ciphers.
Corrects the following:
 Chunk Transfer Encoding over an IPP port might results in print jobs being reset.
 If SSDP = Active (Web Image Monitor > Configuration > Network Security), a high load
on the CPU might result in the MFP stalling with an SC899 error.
 MFP with an external controller will lose network connectivity. This only occurred if the
network settings were changed repeatedly and the MFP's "NetWare" setting was already
"Active" (before the network settings were changed).
…continued

Page 21 of 29
Firmware History for M022/M024/M026/M028

FIRMWARE
NETWORK FIRMWARE
VERSION
Corrects the following: 10.54
 The MFP icon may not be shown in the Windows “Network” dialogue if SSDP is enabled.
This affected Windows Vista, 2008/R2, and 7.
 The device may lose network connectivity if SSDP is enabled. Network connectivity could
be temporarily restored after a power cycle.
Corrects the following: 10.55
 Use of an IP address to send a Scan to SMB may result in the scanned document not
being sent.
Corrects the following: 10.56
 Scan to SMB fails if the both of the following conditions are met.
 Either the device has NBT disabled or it is enabled but the device is unable to
resolve the destination's NetBIOS name.
 One or more octets in the destination's IPv4 address contain leading zeros.
 If the device's IPP Authentication setting is enabled, the driver cannot be installed on
Windows 2008 R2 SP1 or 7 SP1 using an IPP port.
 Jobs were intermittently cancelled if "LPR Byte Counting Enabled" was unchecked for
LPR ports.
Corrects the following: 10.57
 Printer hangs when multiple jobs are submitted in the same session to the printer's lpd
from AS/400, HP-UX or Solaris.
Corrects the following: 10.58
 SC991 might occur and network functions could not be used. This occurs if DHCP and
DDNS are both enabled in the device and if the DHCP server distributes to the device an
FQDN that is more than 127 byte in length.
 Device applications or services that use any of port 80, 443, 7443 or 7444 could not be
used. This occurs if the illegal packet is sent after SSL negotiation handshake to any of
the device's TCP ports 443, 7443 or 7444. Affected applications include Web Image
Monitor, IPP Printing and @Remote.
Corrects the following: 10.59
 If "CNAME" is specified as the destination folder, ScanTo Folder will abort.
 If NBT is disabled, the destination for Scan to Folder might not be displayed and
Windows authentication might fail.
 Cannot scan to shared folders in Windows 8 and Windows Server 2012.
 Cannot scan to shared folders in Mac OS X 10.7 or Mac OS X 10.8.
 This firmware is dependent on the following firmware modules. Please be sure to update
all of them:
System/Copy firmware v2.07 or later
Other changes: 10.60
 Newly added SMBv2/v3 support.
 This firmware is dependent on the following firmware modules. Please be sure to
update all of them:
 System/Copy v2.11 (M0265771T)
 Network Support v10.60 (M0265792L)
 Web Support v1.04 (M0265788F)
 Scanner v01.06 (M0265777E)

Page 22 of 29
Firmware History for M022/M024/M026/M028

15. MEDIAPRINT FIRMWARE ver. 1.01.00:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.00.00 M0265798B 1st Mass Production
1.01.00 M0265798C December 2010 Production

15.1 MEDIAPRINT FIRMWARE HISTORY:


FIRMWARE
MEDIAPRINT FIRMWARE
VERSION
Initial Production Release 1.00.00
Corrects the following: 1.01.00
 Minor bug correction.

Page 23 of 29
Firmware History for M022/M024/M026/M028

16. LANGUAGE INSTALL FIRMWARE ver. 1.04:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.01 M0265791 1st Mass Production
1.03 M0265791A March 2012 Production
1.04 M0265791B June 2012 Production

16.1 LANGUAGE FIRMWARE HISTORY:


FIRMWARE
LANGUAGE FIRMWARE
VERSION
Initial Production Release 1.01
Other changes: 1.03
 A software button was added to the Copier screen, which can be assigned to specific
SDK applications.
Note: In order to utilize this change, the SDK application itself must also support this
functionality
 A cautionary message will be displayed while the machine is performing the encryption of
the hard disk (equivalent to "Do not turn off the power while the encryption is in
progress").
Corrects the following: 1.04
 The error message "ITB unit is not set correctly" is not displayed in Russian.

Page 24 of 29
Firmware History for M022/M024/M026/M028

17. FAX FIRMWARE ver. 04.00.00:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
01.00.00 M0265774B 1st Mass Production
02.00.00 M0265774C April 2012
03.00.00 M0265774D June 2012
04.00.00 M0265774E April 2013

17.1 FAX FIRMWARE HISTORY:


FIRMWARE
FAX FIRMWARE
VERSION
Initial Production Release 01.00.00
Other changes: 02.00.00
 Minor bug correction.
Corrects the following: 03.00.00
 The following may occur when using an SDK application.
- The FAX function does not appear in the User Tools menu
- The FAX function cannot be accessed from the LCD
- The machine cannot be rebooted from inside WIM, and the following message is
displayed:
"This device is currently in use by other functions. Please try again later."
Corrects the following: 04.00.00
 The machine freezes if a FAX is received during a Copy job that has been in progress for
at least two minutes.

NOTE: This can only be cleared by turning the main power OFF/ON.

Page 25 of 29
Firmware History for M022/M024/M026/M028

18. POWERSAVING SYSTEM FIRMWARE ver. F.17:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
F.13 M0265773A 1st Mass Production
F.13 M0265773A August 2010 Production
F.14 M0265773B March 2011 Production
F.15 M0265773C April 2011 Production
F.16 M0265773D November 2011 Production
F.17 M0265773E April 2013 Production

18.1 POWERSAVING SYSTEM FIRMWARE HISTORY:


FIRMWARE
POWERSAVING SYSTEM FIRMWARE
VERSION
Initial Production Release F.13
Corrects the following: F.13
 Minor bug corrections.
Corrects the following: F.14
 Minor bug corrections.
Corrects the following: F.15
 The machine cannot recover from Energy Saver mode after the Power Saving System
firmware is updated to F.14.
Corrects the following: F.16
 SC816-38 occurs when the ADF is opened or originals are put on ADF after the machine
recovers from energy saving mode.
 Machine does not detect paper size after recovering from energy saving mode when ADF
is opened or originals are put on the ADF.
 SC816-94 occurs when the machine receives SNMP packet while in energy saving
mode.
Corrects the following: F.17
 Margin improvement for SC816-26 and SC816-49.

Page 26 of 29
Firmware History for M022/M024/M026/M028

19. FCU (WW) FIRMWARE ver. 05.00.00:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
01.00.00 D4835570A 1st Mass Production
02.00.00 D4835570B June 2011
03.00.00 D4835570C April 2012
04.00.00 D4835570D January 2013
05.00.00 D4835570E April 2016

19.1 FCU (WW) FIRMWARE HISTORY:


FIRMWARE
FCU (WW) FIRMWARE
VERSION
Initial Production Release 01.00.00
Corrects the following: 02.00.00
 FAX reception fails when receiving from a specific FAX server.
Corrects the following: 03.00.00
 Minor bug correction.
Corrects the following: 04.00.00
 The number of FAX pages printed out does not match the number that appears in the Job
Log.
 The number of pages printed out does not match the number that appears in the Job Log,
if the machine main power is turned OFF/ON while the machine is receiving a FAX.
Corrects the following: 05.00.00
 If an error (error codes: 14~30) occurs when sending data to a folder, received
document(s) may disappear without notice via the automatic communication
failure report or automatic output of the received document(s).

Page 27 of 29
Firmware History for M022/M024/M026/M028

20. FINISHER FIRMWARE ver. 01.030:08:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
1.010:08 M665153B 1st Mass Production
1.030:08 M665153C January 2014

20.1 FINISHER FIRMWARE HISTORY:


FIRMWARE
FINISHER FIRMWARE
VERSION
Initial Production Release 1.010:08
Corrects the following: 1.030:08
 Stapled sheets are shifted slightly when printing out at 1200dpi.

Page 28 of 29
Firmware History for M022/M024/M026/M028

21. ADF FIRMWARE ver. 01.030:04:

PROGRAM
VERSION PRODUCTION DATE
NUMBER
01.020:04 M3645604B 1st Mass Production
01.030:04 M3645604C June 2014

21.1 ADF FIRMWARE HISTORY:


FIRMWARE
ADF FIRMWARE
VERSION
Initial Production Release 01.020:04
Other changes: 01.030:04
 Supports copying and scanning of mixed letter and legal sized originals ("LT/LG Mixed
Sizes").
IMPORTANT: To use this feature, make sure that the following firmware versions or
newer are also installed.
System/Copy: v2.03 (M0525771G) or later
Scanner: v01.04 (M0525777C) or later
ADF: v01.030:04 (M3645604C)

Page 29 of 29