Вы находитесь на странице: 1из 12

AUTOCLAVES

“The process of scientific discovery is, in effect, a continual flight from wonder.”
Albert Einstein
Electric Autoclave for sterilisation

THREE DIFFERENT CONTROL SYSTEMS:

CONTROL BY PRESSURE WITH ATMOSPHERIC PURGE:


MICROCLAVE 2 - MEDICLAVE 12

MICROPROCESSOR CONTROL OF
TEMPERATURE AND STERILISATION CYCLE,
ATMOSPHERIC AIR PURGE:
PRESOCLAVE II 30 (mod. vertical)
PRESOCLAVE II 50 (mod. vertical)
PRESOCLAVE II 75 (mod. vertical)
MICROPROCESSOR CONTROL OF TEMPERATURE AND STERILISATION CYCLE,
PULSED VACUUM AIR PURGE:
AUTESTER ST DRY PV-B 12 (mod. horizontal) AUTESTER ST DRY PV-II 30 (mod. vertical)
AUTESTER ST DRY PV-B 18 (mod. horizontal) AUTESTER ST DRY PV-II 50 (mod. vertical)
AUTESTER ST DRY PV-B 25 (mod. horizontal) AUTESTER ST DRY PV-II 75 (mod. vertical)
AUTESTER ST DRY PV-II 140 (mod. vertical)

SUMMARY TABLE OF MODEL RANGE QUICK OVERVIEW


MODELS Part No. System Capacity Temperature Pressure Power Control Purge Type
DRY litres °C bar W control

MICROCLAVE 2 4001404 NO 7 121 and 127 1 and 1.5 1000 Pressure thermostat Atmospheric Vertical bench top
MEDICLAVE 12 4047725 NO 12 121 and 134 1 and 2 1800 Pressure thermostat Atmospheric Vertical bench top
PRESOCLAVE II 30 4002135 NO 30 115 to 134 0.62 to 2 2800 Electronic controller Atmospheric Vertical
PRESOCLAVE II 50 4001725 NO 50 115 to 134 0.62 to 2 3600 Electronic controller Atmospheric Vertical
PRESOCLAVE II 75 4002136 NO 75 115 to 134 0.62 to 2 3600 Electronic controller Atmospheric Vertical
AUTESTER ST DRY PV-B 12 4001727 YES 12 121 and 134 1 and 2 1800 Microprocesador Purged vacuum Horizontal bench top
AUTESTER ST DRY PV-B 18 4001728 YES 18 121 and 134 1 and 2 1800 Microprocesador Purged vacuum Horizontal bench top
AUTESTER ST DRY PV-B 25 4002414 YES 25 105-121 and 134 0.21-1 and 2 2510 Microprocesador Purged vacuum Horizontal bench top
AUTESTER ST DRY PV-II 30 4002514 YES 30 105 to 134 0.21 to 2 2800 Microprocesador Purged vacuum Vertical
AUTESTER ST DRY PV-II 50 4002515 YES 50 105 to 134 0.21 to 2 3600 Microprocesador Purged vacuum Vertical
AUTESTER ST DRY PV-II 75 4002425 YES 75 105 to 134 0.21 to 2 3600 Microprocesador Purged vacuum Vertical
AUTESTER ST DRY PV-II 140 4002426 YES 140 105 to 134 0.21 to 2 7500 Microprocesador Purged vacuum Vertical

48 Autoclaves
Electric Autoclave for sterilisation “Microclave 2”
PRESSURE REGULATOR THERMOSTAT OF 1 AND 1.5 bar. TEMPERATURES 121 °C AND 127 °C.
VERTICAL TABLE TOP. CAPACITY: 7 LITRES.
SAFETY:
OVER PRESSURE VALVE, PREVENTS THE PRESSURE PASSING THE SET
MAXIMUM LIMIT. THERMALLY PROTECTED INSULATED LID.

FEATURES
Stainless steel AISI 304 exterior and top.
INCOLOY heater element. provides long life, resistant to corrosion and high tempe-
ratures.
The chamber and lid are made of aluminium alloy with P.T.F.E. coating.
Manual air purge and bleed valve.
Simple secure bayonet type lid.

CONTROL PANEL
Illumninated mains switch indicator.
Pressure selection.
Timer 0 to 120 minutes.
Pressure gauge.
Indicator lamps showing when the heater is on.
Indicator lamps showing when the heater is on at 121 °C.
Indicator lamps showing when the heater is on at 127 °C.

MODEL Part No. Capacity Ø Height Height Width Depth Power Weight
litres (usable) cm (exterior) cm W Kg

MICROCLAVE 2 4001404 7 24.5 15 40 28 33 1000 13


Comes complete with a perforated basket made from AISI316 stainless steel of Ø 21.5 x 15 cm high.

Sterilising Electric Autoclave “Mediclave 12”


PRESSURE REGULATOR THERMOSTAT OF 1 AND 2 bar. TEMPERATURES 121 °C AND 134 °C.
CONFORMS TO THE EXISTING PRESSURE DIRECTIVE.
VERTICAL TABLE TOP. CAPACITY: 12 LITRES.
SAFETY:
OVER PRESSURE SAFETY VALVE: PREVENTS THE PRESSURE WITHIN THE AUTOCLAVE PASSING THE MAXIMUM SET LIMIT.
SAFETY PRESSURE : DISCONNECTS POWER TO THE HEATER IN THE CASE THAT THE PRESSURE EXCEEDS THE SET LIMIT.
SAFETY THERMOSTAT: CUTS POWER TO THE HEATER IN THE CASE OF OVER TEMPERATURE OR LOW WATER LEVEL.
THERMALLY INSULATED TOP TO PREVENT BURNS.

Semi-automatic
FEATURES
Stainless steel AISI 304 exterior and top.
INCOLOY heater element. Provides long life, resistant to corrosion and high tempe-
ratures.
The chamber and lid are made of AISI 316 stainless steel.
Automatic pulsed air inlet.

CONTROL PANEL
Illuminated mains switch.
Pressure selection.
Timer 0 to 60 minutes.
Pressure gauge.
Indicator lamp showing when the heater is on.
Indicator lamp showing that the safety thermostat is in operation.
Indicator lamp showing when the heater is at 121 °C.
Indicator lamp showing when the heater is at 134 °C.
Indicator lamp showing end of cycle.

MODEL Part No. Capacity Ø Height Height Width Depth Power Weight
litres (usable) cm (exterior) cm W Kg

MEDICLAVE 12 4047725 12 24.5 25 50 38 50 1800 18


Comes complete with a perforated basket made from AISI316 stainless steel of Ø 22.5 x 24 cm high.

Autoclaves 49
Autoclaves for sterilisation “Presoclave II” 30, 50 and 75
MICROPROCESSOR CONTROL OF TEMPERATURE CYCLE AND PURGE TO ATMOSPHERE.
ELECTRONIC CONTROL OF TIME AND TEMPERATURE WITH DIGITAL DISPLAY TEMPERATURE RANGE FROM 115 °C TO 134 °C
(0.62 TO 2 bar).
CONFORMS TO APPARATUS PRESSURE REGULATION NORMATIVES.
VERTICAL MODEL: 30, 50 AND 75 LITRES.
SAFETY:
SAFETY OVER PRESSURE VALVE: PREVENTS OVER PRESSURE ABOVE THE MAXIMUM SET LIMIT.
SAFETY PRESSURE SWITCH: DISCONNECTS POWER TO THE HEATER IF THE UNIT EXCEED THE MAXIMUM PRESSURE LIMIT.
SAFETY THERMOSTAT AND WATER LEVEL: DISCONNECT POWER TO THE HEATER IF INSUFFICIENT WATER OR OVER TEMPERATURE.
SAFETY LID: PREVENTS THE LID BEING OPENED IF THE CHAMBER IS UNDER PRESSURE.
SAFETY INSULATION: THERMALLY INSULATED LID .

An economic alternative, semi- automatic


NEW
FEATURES
External case made from AISI 304 stainless steel.
INCOLOY stainless steel heater elements, hard waring, resistant to corrosion and
high temperatures.
Sterilisation chamber and door made from AISI 316 stainless steel.
Automatic purge to atmosphere
Lid,6 point closure.

CONTROL PANEL
1

2
3
4 13
5
6
7
8
9
10
11
12

1. Pressure gauge.
2. Illuminated alarm indicator.
3. Illuminated indicator end of cycle.
4. Illuminated indicator door open
5. Temperature display.
6. Time display
7. Temperature set pushbutton (range from 115 °C to 134 °C).
8. Pushbutton increase value.
9. Push button START
10. Push Button STOP
11. Push button Reduce value. BACK VIEW:
12. Push button select time, (range from 3’ to 59’).
13. Push button open lid. 1
1. Mains power.
MODELS Part No. Capacity Ø Height Height / Width / Depth Power Weight
2 2. Safety valve.
litres (usables cm) (exterior cm) W Kg
3 3. Steam empty valve.
4. Safety thermostat
PRESOCLAVE II 30 4002135 30 30 40 97 48 62 2800 62 4 5. Drain selector valve.
PRESOCLAVE II 50 4001725 50 30 70 117 48 62 3000 75
5
PRESOCLAVE II 75 4002136 75 40 60 107 58 72 3600 100
Does not include baskets, order separately.

ACCESSORIES: AISI 316 Stainless steel baskets. Sterilisation drum made from
AISI 304 stainless steel. Detergent Bio-Sel. Water distillation unit especially OPTIONS: That need to be factory installed:
for autoclaves (see page 53). Pt100 second sensor only temperature reader (see page 53).

50 Autoclaves
Autoclaves for sterilisation “Autester ST DRY PV II”
MICROPROCESSOR TEMPERATURE AND CYCLE CONTROL AND PULSED VACUUM PURGE SYSTEM.
AUTOMATIC VACUUM DRY AND PURGE “PREVACUUM”
PROGRAMMABLE TEMPERATURE FROM 105 °C TO 134 °C (0.21 TO 2 bar).
CONFORMS WITH THE CURRENT REGULATIONS FOR PRESSURE VESSELS.
VERTICAL FLOOR STANDING MODEL: 30, 50, 75 AND 140 LITRES.
CONFORMITY
EN 61010-1 SAFETY FOR EQUIPMENT FOR LABORATORY USE
EN 61010-2-041 SAFETY FOR STERILISER EQUIPMENT FOR LABORATORY USE
EN 61326 ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT FOR LABORATORY USE.

FEATURES
AISI 304 stainless steel exterior and top.
AISI 316 stainless steel lid
Lid, six closure point system.
Pulsed vacuum system and atmosphere purge. NEW
Incorporated steam generator, connected to the main chamber.
Water reservoir for clean water for the steam generator boiler.
External water connection if required.
6 function modes.
Printer output. RS232 connection for download or to a printer.
Connection for a second temperature sensor
Memory for 9 customer set programs.

SAFETY
Safety: The lid cannot be opened if the chamber is under pressure.
Safety valve: Prevents over pressure over the maximum limit.
Safety pressure switch: switches power off to the heater if over pressure.
Safety Lid: insulated lid protection.

DIAGRAM SHOWING THE FUNCTION CYCLE AUTESTER ST DRY PV II

CONTROL PANEL

5 10 11 BACK VIEW
6
1 1. Mains input.
1 2. External water supply.
2 2 3. Safety valve.
4. Vacuum vapour valve.
3 5. Air in filter valve.
4 6. Safety thermostat.
3 7. Safety thermostat.
4 5
8. Empty tank valve.
6 9. Drain tank valve.
1. LCD parameter indicator. 4. Push button Start / Stop. 7 10. RS232 Printer connection.
2. MONO single button control multi- 5. Printer (optional). 11. 2nd Temperature sensor con
8 nection.
function processor. 6. Open Lid.
3. LED in operation. 9

Autoclaves 51
CONFORMITY

The microprocessor controls the air extraction, sterilisation and dry process from preset values set by the
operator. Controlled parameters are:
• Sterilisation temperature from 105 °C • Configuration
to 134 °C - Units
• Sterilisation time from 3’ to 60’. - Languages ( Spanish, English, and
• Drying time from 20’ to 60’ French).
• Programs-0 to 9 user configurable - Printer
• Six pre-set functions: - Timer: date/hour
- Solids 1 fraction - Water connection external: on/off.
- Solids 2 fractions • Password
- Solids 3 fractions • Calibration
- Dry - Temperature probe 1
- Liquids - Temperature probe 2
- Liquids 2 temperature probes - Water fill
• Verification tests
- Vacuum
- Bowie Dick

Error messages of functions or execution of a program are displayed and an acoustic alarm sounds.
The vapour generator automatically cuts out.
MESSAGES:
1. E 2PROM 10. TEMPERATURE LOW FAULT
2. RTC FAULT 11. INPUT ERROR
3. SENSOR PRECISION 12. STERILISATION
4. HEATER PROBE 13. LEVEL 1
5. CHAMBER PROBE 14. LEVEL 2
6. OVER PRESSURE 15. DOOR
7. VACUUM 16. PRINTER, NO PAPER
8. PRESSURE 17. PAPER JAM
9. BOILER TEMPERATURE 18. ELECTRICAL FAULT

MODELS Part No. Dry Capacity Ø / Height Height / Width / Depth Temp. Water Basket Power Weight
litres (usables) cm (exterior) cm °C Reservoir size W Kg
H2O capacity.

AUTESTER ST DRY PV-II 30 4002514 Yes 30 30 40 97 48 62 105 to 134 10 2 2800 90


AUTESTER ST DRY PV-II 50 4002515 Yes 50 30 70 117 48 62 105 to 134 10 3 3000 108
AUTESTER ST DRY PV-II 75 4002425 Yes 75 40 60 107 58 72 105 to 134 10 2 3600 136
AUTESTER ST DRY PV-II 140* 4002426 Yes 140 50 70 118 80 95 105 to 134 20 3 7500* 250
Comes without baskets.
* The part number 4002426 due to its power rating, only manufactured for three phase 220V or 380V, specify preference when ordering.

OPTIONS: Factory fitted options PARAMETERS AND PROGRAMS PRE INSTALLED IN THE AUTOCLAVE MICROPROCESSOR
(Note: All these parameters are adjustable by the user)

Thermal printer continuous paper roll with Nº Description Temperature Time Time Purge
Programme Sterilisation Sterilisation Dry
print out of temperature, pressure, time and
mode. 0 Free - - - -
Part No. 4002417 1 Unwrapped instruments 134 °C 4 min 15 min 2 (1)
2 Wrapped instruments 134 °C 12 min 30 min 3 (2)
3 CJD 134 °C 20 min 20 min 3 (2)
4 Delicate unwrapped 121 °C 15 min 15 min 2 (1)
Pt100 Sensor 5 Delicate wrapped 121 °C 30 min 30 min 3 (2)
(See page 53). 6 Disinfecting 105 °C 25 min 15 min 1 (3)
7 Liquids 121 °C 30 min - 1 (3)
ACCESSORIES 8 Solids 121 °C 15 min 30 min 1 (3)
AISI 316 Stainless steel baskets. 9 Solids 134 °C 4 min 30 min 1 (3)
Sterilisation drum made from AISI 304 stainless steel.
Detergent Bio-Sel. (1) Double Vacuum purge.
Water distillation unit especially for autoclaves (2) Triple Vacuum purge.
(see page 53). (3) Atmospheric purge (No vacuum).

52 Autoclaves
OPTIONS: for vertical autoclaves, need to be factory fitted.

Pt 100 Sensor. 2nd Probe for reading sample temperature.


To guarantee in all circumstances that the system has completed the cycle to the set time and tempera-
ture parameters, the Autester ST DRY PV II autoclave can be installed with a temperature probe that can
be placed within the culture flask, residual packets etc. In this way proof that the programmed time and
temperature for the run have been achieved.
When the probe is connected to the controller of the autoclave, it is automatically recognised by the micro-
processor, whereby the real time and temperature values detected by the probe are displayed and printed.
For autoclaves PRESOCLAVE II this Pt100 sensor only temperature reader.
Part No. 4001219

ACCESSORIES FOR VERTICAL AUTOCLAVES


Perforated AISI 316 stainless steel baskets.
Part No. Ø Height Suitable for autoclaves Number of
cm Part No. baskets

1004770 21.5 15 4001404 1


1000596 22.5 24 4047725 1
1000495 28 20 4002135 - 4002514 2
1000495 28 20 4001725 - 4002515 3
1000496 38 28 4002136 - 4002425 2
1000780 48 22 4002426 3

AISI 316 stainless steel wire dividers for autoclave baskets.


Part No.
1001217 4 divider compartments for basket part no. 1000495.
1001218 6 divider compartments for basket part no. 1000496.
1001222 7 divider compartments for basket part no. 1000780.

Sterilisation Drums.
Part No. Ø Height Suitable for autoclaves Capacity
cm Part No. Drums

1002418 28 18 4002135 - 4002514 2


1002418 28 18 4001725 - 4002515 3
1002419 35 27 4002136 - 4002425 2

Water distiller, specially for autoclaves “DEST-4”.


Distillation capacity: 1.5 litres/hour. Internal capacity 4 litres. No
NEW external
Case made from thermo resistant plastic. additional
Internal stainless steel. water
Cooling by forced air though a condenser. Without glass heater elements. required
Easy to use. Safety cut out if over temperature due to insufficient water.
Comes complete with a 4 litre three way dispenser plastic bottle with filter.
Note: for daily use it is recommended that the filter be changed every 3 months.
Part No. Capacity Conductivity Ø Height Power Weight
Distillation litre/Hour µs/cm cm W Kg

4001729 1.5 5 29 39 750 3.5


Spare: Dispenser spout with filter. Part No. 4001730
Detergent “BIO-SEL”
We recommend the use of BIO-Sel detergent for cleaning, it is also biodegradable and free from
Phosphates.
Part No.
1000025 Capacity 1 litre.
1000026 Capacity 4 litres.
1000852 Box of 12 x 1 litre flasks.
1000853 Box of 4 x 4 litre flasks.

Autoclaves 53
Sterilisation autoclave “Autester ST DRY PV” Class B
AUTOMATIC VACUUM DRY AND PURGE.
PROGRAMS TO 105 °C, 121 °C AND 134 °C (0.21 – 1 AND 2 bar).
MODEL HORIZONTAL. CAPACITY: 12, 18 AND 25 LITRES.

APPLICATIONS
"Class B" autoclaves are used within the field of general medicine, dentistry, veteri- To guarantee sterilisation of these materials the “AUTESTER ST DRY PV” Class B, au-
nary, tattoo parlours and sterilisation applications in general, to sterilise any material toclaves, have an efficient staged vacuum, that performs a complete extraction of air
that could have been in contact with body fluids including blood. that allows penetration of the steam vapour.
The general capabilities of the instrument are regulated by EN 13060 that guarante- The same vacuum system is used to obtain the dry phase, which is required for per-
es the differing sterilisation applications. fect storage of sterilised materials.
The normal processes include: Solids with and without wrapping, porous material The “AUTOCLAVES ST DRY PV” Class B includes verification and validation pro-
with and without wrapping and utensils that have cavities and holes (e.g. dentistry grams.
materials.)

CONFORMITY:
EN 13060-1 SMALL GENERAL PURPOSE STEAM STERILISERS.
EN 13060-2 SMALL STEAM STERILISER: SPECIFIC TO "CLASS B"
EN 61010-1 EQUIPMENT SAFE FOR LABORATORY USE.
EN 61010-2-041 SAFETY FOR STERILISER EQUIPMENT FOR LABORATORY USE
EN 61326 ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT USED IN THE LABORATORY.

SAFETY:
SAFETY VALVE: PREVENTS THE PRESSURE EXCEEDING THE MAXIMUM SET LIMIT.
SAFETY THERMOSTAT: DISCONNECTS THE HEATER AGAINST OVER TEMPERATURE OR LOW WATER IN THE RESERVOIR.
THERMALLY INSULATED LID.

NEW

25 litres
12 litres

18 litres

Staged fractional vacuum: Extracts air from the load


that permits absolute steam vapour penetration.

Sterilisation stage: Sterilisation within the time and


temperature selected.

Dry cycle: Extracts the humidity from the load leaving it


suitable for storage.

54 Autoclaves
Sterilisation Autoclaves “Autester ST DRY PV” 12 Class B
CAPACITY: 12 LITRES.
CONFORMS TO THE FOLLOWING REGULATIONS:
- 97/23/CEE EQUIPMENT UNDER PRESSURE. PART 3.3
- 93/42/CEE SANITARY EQUIPMENT, REGISTERED ORGANISM 0197

FEATURES
Stainless steel internal chamber.
Staged vacuum purge.
Dry by vacuum
Incorporated steam generator.
Water reservoir to supply the chamber
High vapour penetration of porous material
Used in digestive studies, ophthalmology, operating
theatres etc .
Printer interface.

SAFETY
Safety valve. Prevents over pressure over the maxi-
mum working limit.
Safety thermostat. Disconnects power to the heater
if over temperature or low water in the reservoir.
Thermally protected lid. NEW

CONTROL PANEL 9
1 5
1. Textile materials 10. Select wrapped or non wrapped.
2 4 2. 121 °C. 11. Test.
3 10 3. 134 °C. 12. Fast sterilisation.
4. Wrapped solids. 13. "maintain hot" the chamber.
15 11 5. Solids (Not wrapped). 14. Preheat.
16 12 6. Low level water indicator. 15. Pressure indicator (bar).
7. Autoclave ready for operation. 16. Temperature indicator (°C).
17 13
8. Sterilisation cycle in process 17. Time Indicator (min.).
14 9. Program selection.
6
7
8

PROGRAMS 134 °C 134 °C 121 °C 121 °C Test Test


Wrapped Not Wrapped Wrapped Not Wrapped Textiles Bowie Dick Vacuum

Sterilisation Temperature 134 °C 134 °C 121 °C 121 °C 134 °C 134 °C -


Sterilisation pressure 2.1 bar 2.1 bar 1.1 bar 1.1 bar 2.1 bar - 2.1 bar
Vacuum purge time 8 min. 4 min. 8 min. 4 min. 8 min. - -
Sterilisation time 12 min. 4 min. 30 min. 20 min. 12 min. 3.5 min. 10 min.
Dry time 10 min. 10 min. 10 min. 10 min. 15 min. 1 min. -

MODEL Part No. Capacity Ø / depth External Dimensions Power Weight


litres cm cm W kg
Height Width Depth

AUTESTER ST DRY PV B 12 4001727 12 20 35 39.2 48.7 60 1800 42.2

ACCESSORIES
Comes complete with:
Water in tube, door ad- Ink Printer (no thermal).
justment key, support Paper size 2 1/4’’ (56 mm) wide.
with three trays, extrac- Includes communications and power cable.
tor forceps, empty water Model
filter and waste water Part No. Height/Width/Depth Power Weight
out. cm Kg

4120113 4 16 10 DC 5V 3A 1

Water distiller especially for Autoclaves. (See page 53).

Autoclaves 55
Sterilisation Autoclaves “Autester ST DRY PV” 18 Class B
CAPACITY: 18 LITRES.
CONFORMS TO THE FOLLOWING REGULATIONS:
- 97/23/CEE EQUIPMENT UNDER PRESSURE. PART 3.3
- 93/42/CEE SANITARY EQUIPMENT, REGISTERED ORGANISM 0197

FEATURES
Stainless steel internal chamber.
Staged vacuum purge.
Dry by vacuum
Incorporated steam generator.
Water reservoir to supply the chamber
High vapour penetration of porous material
Used in digestive studies, ophthalmology, operating
theatres etc .
Printer interface

SAFETY
Positive door lock, prevents the door being opened
accidentally.
Safety valve. Prevents over pressure over the maxi-
mum working limit.
Safety thermostat. Disconnect power to the heaters if
over temperature or low water in the reservoir.
Thermally insulated lid.

CONTROL PANEL

NEW

2
6
1 1. Start - Stop.
2. LCD screen.
3 3. Cancel - Menu.
4. Validation.
5. Rapid cycle.
4 6. Validation time.
5

PROGRAMS 134 °C 134 °C 134 °C 121 °C Test Test


Wrapped Not Wrapped Not Wrapped Fast Wrapped Bowie Dick Vacuum

Sterilisation Temperature 134 °C 134 °C 134 °C 121 °C 134 °C -


Sterilisation pressure 2.1 bar 2.1 bar 2.1 bar 1.1 bar - 2.1 bar
Vacuum purge time 10 min. 10 min. 4 min. 10 min. - -
Sterilisation time 18 min. 4 min. 4 min. 16 min. 3.5 min. 10 min.
Dry time 10 min. 10 min. 10 min. 10 min. 1 min. -

MODEL Part No. Capacity Ø x depth External Dimensions Power Weight


litres cm cm W kg
Height Width Depth

AUTESTER ST DRY PV B 18 4001728 18 25 35 49.5 46 60 1800 46.6

ACCESSORIES
Comes complete with:
Water in tube, door ad- Ink Printer (no thermal).
justment key, support Paper size 2 1/4’’ (56 mm) wide.
with three trays, extrac- Includes communications and power cable.
tor forceps, empty water Model
filter and waste water Part No. Height/Width/Depth Power Weight
out. cm Kg

4120113 4 16 10 DC 5V 3A 1

Water distiller especially for Autoclaves. (See page 53).

56 Autoclaves
Sterilisation Autoclaves “Autester ST DRY PV” 25 Class B
CAPACITY: 25 LITRES.
CONFORMS TO THE REGULATION - 97/23/CEE EQUIPMENT UNDER PRESSURE.

FEATURES
Sterilisation chamber and lid made from AISI 316 stain-
Complete selection of programs.
less steel. Displays in Spanish - English - French.
External case epoxy coated.
Incorporated steam generator separate from the main Output RS-232.
sterilisation chamber.
Digital control of all autoclave operations.
Large back lit LCD 2 x 24 character display.
Air filter, purifies air before entering the sterilisation
chamber.
Separate clean water reservoir for the steam generator
and waste water.
RS-232 Interface output of parameters to a computer.
RS-232 Printer interface.

SAFETY
Safety valve.
Prevents the door being opened if under pressure or
high temperature.
Pressure safety Presostat.
Temperature safety thermostat.
Door closed correctly detector
Thermally protected lid.

ALARMS
Pressure/Temperature reading out of normal value.
Door Open.
Electrical fault.
Over pressure.
Over temperature. NEW
Program error.
Low water.
Water reservoir level full.

MODEL Part No. Capacity Ø/Depth Height/Width/Depth Power Weight


litres (usables) cm (exterior) cm W Kg
CONTROL PANEL AUTESTER ST DRY PV 25 4002414 25 30 35 48 46 55 2510 52

Comes complete with


three trays, extractor for-
ceps, and additional sup-
4 3 1 2 port for instruments and
sterile wrapping bags.
1 - LCD parameter display.
2 - Mono control button of multi functions that selects:
A - PROGRAMS: Temperature Sterilisation time Drying Time ACCESSORIES
°C (minutes) (minutes)

- (1) Fast No wrapping 134 4 10 Ink Printer (no thermal).


- (2) Universal wrapping 134 12 15 Paper size 2 1/4’’ (56 mm) wide.
- (3) C.J.D.Priones 134 20 15 Includes communications and power cable.
- (4) Delicate no wrapping 121 15 20 Model
- (5) Delicate wrapped 121 30 20 Part No. Height/Width/Depth Power Weight
- (6) Universal 121 20 15 cm Kg
- (7) Disinfection 105 10 - 4120113 4 16 10 DC 5V 3A 1
B - FUNCTION CONFIGURE:
Language ( Spanish, English and French) – Printer - Timer - Password
C - TEST: Vacuum test – Bowie Dick test. Water distiller especially for Autoclaves. (See page 53).
D - CALIBRATION: Temperature – Pressure.
3 - LED in operation.
4 - Push button Start - Stop.

Autoclaves 57
Bag sealer “S-400”
SUITABLE FOR POLYPROPYLENE-POLYESTER STERILISING
BAGS WITH A PAPER BASE.
FEATURES CONTROL PANEL
Metal epoxy covered case. Illuminated mains switch.
Pressure sealer. Manual cut. Lamp on when the thermostat has rea-
Stainless steel AISI 304 reel support at ched the pre-set working temperature.
the back.
MODEL
Part No. Seal Width Maximum seal Height / Width / Depth Power Weight
mm length mm (exterior) cm W Kg

4100041 9 270 12 35 21 200 5.3

Bag sealer “Seal-1000”


FOR POLYPROPYLENE AND POLYESTER BAGS WITH A STERI- NEW
LE PAPER BASE.
FEATURES
Metal construction with stainless steel sides to accommodate differing roll
tray. sizes.
Pressure sealer unit with lateral leaver
with two bilateral cutting edges. CONTROL PANEL
Constant sealing temperature (from Illuminated start switch.
180 °C and 200 °C). Indicator, optimum seal temperature.
External support for rolls of up to
240mm wide, with adjustable separator
Part No. Seal width Maximum seal Height / Width / Depth Power Weight
mm length mm (exterior) cm W Kg

4101712 10 260 30 36 43 400 6.5

Automatic bag sealer “Seal-Com”


IN ACCORDANCE WITH DIN 58953 SECTION 7 STANDARD. FOR SEALING STERILE PAPER, POLYPROPYLENE-POLYESTER BAGS.
CONTINUOUS SEALING, AUTOMATIC ADVANCE.
Continuous Thermosealer NEW
DESIGN
FEATURES CONTROL PANEL
Epoxy covered metallic exterior. Luminous heater “ON” switch.
Heating time: 4 minutes. Luminous motor “ON” switch.
Seal width: 9 mm. Start light for the operation of sealing
Sealing speed: 5 m/min. bags.
Removable support tray made of AISI
304 stainless steel.
MODEL
Part No. Height / Width / Depth Width / Depth Power Weight
(sealer) cm (tray) cm W Kg

4100043 19 37 21 50 17 240 8.2

SEALING MACHINE ACCESSORIES

Rolls of paper for sterilisation “Polisteril” Sterile paper “Policort” trimmer Date stamping machine for sterile bags.
Paper base polypropylene and polyester bags showing Completely made of metal with back and reel support,
differing ink prints of sterilised items. for a capacity of 2 x 200mm or 4 x 100 mm wide reels. Part No. 4100046
Part No. Bag width cm Bag length m Circular cutting knife edge. STERILISED
4100075 7,5 100 Measurements: 13 high x 51 wide x 32 cm deep.
30 JULY 2007
4100100 10 100 Weight: 2.8 Kg.
4100200 20 100 Part No. 4100045 VALID FOR 3 MONTHS.

OPTIONS: Ultrasonic cleaning baths for dentistry, “DIGITMED” (see page 82). Dry steriliser “DRYTIME” poupinel oven (see page 123).

888
58 Autoclaves

Вам также может понравиться