Вы находитесь на странице: 1из 2

(Winding Wire Division)

Test Report
Date : 29.08.2020 Test Report : SQ / TR-SE / 29.08.2020 As Per BDS : 1035
As Per IS : 13730-0-1
As Per IEC :
60317-0-1
Wire Size : SWG - 17 Type “Grade” (2) : Surface Finishing : Good

PROPERTIES UNIT SPECIFICATION Sample-1 Sample-2 Sample-3 Remarks


1. PHYSICAL PROPERTIES
i. DIAMETERS
Overall diameter mm Max. 1.528 1.512 1.513 1.512
Conductor diameter mm Min. 1.407 Max. 1.437 1.422 1.422 1.422
Increase in diameter mm Min. 0.071 Max. 0.091 0.090 0.091 0.090
Type of covering grade - 1-2-3 2 2 2
ii. Elongation % Min. 31 40.00 39.00 38.00
iii. Springness Deg. Max. 30 28.00 27 28.00
2. MECHANICAL PROPERTIES
i. Jerk Test - No Cracks / Loss No Cracks / Loss No Cracks / Loss No Cracks / Loss
ii. Mandrel Test - No Crack Found No Crack Found No Crack Found No Crack
3. Thermal Properties Satisfactory

i. Heat Shock at 155°C/0.5 Hour - No Crack Found No Crack Found No Crack Found No Crack

4. ELECTRICAL PROPERTIES
i. Minimum Breakdown Voltage
kV 5.00 12.43 12.23 12.10
0 C At Room Temp.
ii. Continuity of Covering (3 KV DC Pin
Hole Test)
- Max. 5 Faults No Faults No Faults No Faults
DC 1500V/30m

iii. Cut-Through Test (0.10


mm-1.60 mm) - No Failure Found No Failure Found No Failure Found No Failure
110 V, 270° C

Tested By, Checked By,

Md. Yousuf Ali Md. Iqbal Hasan


Sub. Asst. Engineer (CCR) Asst. Manager (QC)
SRN Electronics Limited. SQ Wire & Cable Co., Ltd.