©Inova Automation Co.,Ltd 2016. The information contained in the brochure is for guidance only. All rights reserved L6210028
Integrated Solution
NICE3000+ Serial Communication NICE1000+ Parallel Communication MD380L NICE900
Elevator High Performance Integrated Controller Elevator Generalpurpose Integrated Controller Open Loop Elevator Drive Elevator Door Drive
● Simplex, Duplex and 3~8 Group Elevator Control type ● Simplex and Duplex Elevator Control Function
of elevators ● Medium speed, Low speed
● High Speed, Medium speed, Low speed ● Residential elevator, freight elevator, villa elevator,
● Commercial elevator, residential elevator, villa elevator, passenger elevator, hospital elevator, etc., ● Open Loop elevator drive ● Elevator car door
Applications
passenger elevator, hospital elevator, disabled elevator ● Elevator rated speed ≤1.5m/sec Applications ● Low Speed and Low rise ● Subway car door
etc., ● Supports up to 8 floors as a standard ; Expandable
● Elevator rated speed ≤4.0m/sec up to max 16 floors(Full Collective) with Expansion ● Rated speed up to 1m/s ● Various door control applications
● Supports up to 40 floors as a standard; can adapt up to
max. 64 floors board (MCTC-KZ-D)
● 3 mode of door operation mode: Manual, Semi-Auto, ● 3 mode of door operation mode: Manual, Semi-Auto,
Auto Auto
Asynchronous (Induction) motor Asynchronous (Induction) motor Asynchronous (induction) motor Asynchronous (induction) motor (with/without encoder)
Applicable motor type Synchronous Permanent magnet motor Synchronous Permanent magnet motor Applicable motor type Synchronous permanent magnet motor (with encoder)
Control technology Closed Loop Vector control Closed Loop Vector control Open Loop VF control Open Loop Vector Control
Control technology Sensorless Vector control (SVC) Closed Loop Vector control
Power Rating 2.2kW to 160kW 2.2kW to 55kW
Power Rating 3.7kW to 15kW 200W, 400W, 750W
1Ø, 220Vac to 240Vac (-15% to 10% : 187Vac to 264Vac) 1Ø, 220Vac to 240Vac (-15% to 10% : 187Vac to 264Vac)
AC Voltage 3Ø, 220Vac to 240Vac (-15% to 10% : 187Vac to 264Vac) 3Ø, 220Vac to 240Vac (-15% to 10% : 187Vac to 264Vac) 3Ø, 380Vac to 480Vac (-15% to 10% : 323Vac to 528Vac) 1Ø, 220Vac to 240Vac (-15% to 10% : 187Vac to 264Vac)
3Ø, 380Vac to 480Vac (-15% to 10% : 323Vac to 528Vac)
AC Voltage
3Ø, 380Vac to 480Vac (-15% to 10% : 323Vac to 528Vac) 1Ø, 200Vac to 240Vac (-15% to 10% : 187Vac to 264Vac)
Start torque 0Hz/200% (Closed Loop) 0.5Hz/180% (Open Loop) 1Hz/150% (Open Loop)
0Hz/200% (Closed Loop) Start torque
0Hz/180% (Closed Loop)
Speed control range 1 : 1000 (Closed Loop) 1 : 1000 (Closed Loop) Speed control range 1 : 100 (Open Loop) 1 : 50 (Open Loop) 1 : 1000 (Closed Loop)
Speed accuracy ±0.05% (Closed Loop) ±0.05% (Closed Loop) Speed accuracy ±0.5% (Open Loop) ±0.5% (Open Loop) ±0.05% (Closed Loop)
Torque control accuracy ±5% (Closed Loop) ±5% (Closed Loop) Torque control accuracy ±5% (Open Loop) ±5%(Closed Loop)
150% rated current for 60 seconds; 150% rated current for 60 seconds; 150% rated current for 60 seconds; 150% rated current for 60 seconds;
Overload capability Overload capability
200% rated current for 1 second 200% rated current for 1 second 180% rated current for 1 second 180% rated current for 1 second
Motor Parameter Yes, Static (without brake opening) and rotating auto-tuning for asynchronous Yes, Static (without brake opening) and rotating auto-tuning for asynchronous Motor Parameter Yes, Static and rotating auto-tuning for asynchronous Yes, Static and rotating auto-tuning for asynchronous
(induction) and PM synchronous motor with load and without load (induction) and PM synchronous motor with load and without load (induction) motor with load and without load (induction) and rotating tuning for PM synchronous
auto-turning auto-tuning
motor with load or without load
Based on displacement calculation methods derive N velocity profile to Based on displacement calculation methods derive N velocity profile to
Acceleration/Deceleration achieve optimum direct-to-point distance control achieve optimum direct-to-point distance control Acceleration/Deceleration Enhanced and flexible S-ramp Enhanced and flexible S-ramp
Yes. On the occasion when elevator stops at the floor level and a large Yes. On the occasion when elevator stops at the floor level and a large
number of persons or goods enter or leaves, the levelling fluctuates number of persons or goods enter or leaves, the levelling fluctuates
because of the elastic deformation of elevator wire ropes and rubber. because of the elastic deformation of elevator wire ropes and rubber.
Re-levelling function With this intelligent Re-levelling function, the system is allowed to run With this intelligent Re-levelling function, the system is allowed to run
Re-Levelling function N/A N/A
automatically at the re-levelling speed to the floor level with door open. automatically at the re-levelling speed to the floor level with door open.
Requires MCTC-SCB-A Requires MCTC-SCB-A
Yes. By the principle of distance, automatically generates the smooth Yes. By the principle of distance, automatically generates the smooth
Direct-to-floor function curves from start of parking, no crawling, directly stop in the levelling curves from start of parking, no crawling, directly stop in the levelling Direct-to-floor function N/A N/A
position position
New and reliable compulsive terminal deceleration function helps to New and reliable compulsive terminal deceleration function helps to
Forced deceleration identify the deceleration point automatically identify the deceleration point automatically Forced deceleration N/A N/A
Shaft parameter 32-Bit data, record the elevator car shaft position before first run Shaft parameter N/A 16-Bit data, record the elevator car door position
self-learning 32-Bit data, record the elevator car shaft position before first run self-learning before first run
Individual floor levelling adjustment function through COP Flexible and easy floor levelling adjustment Flexible and easy door open & close position
Levelling adjustment Individual floor levelling adjustment function through COP Levelling adjustment
adjustment function
In-built real time clock to facilitate time-sharing control and elevator
Real time clock N/A Real time clock N/A N/A
management
24 Digital input terminals (Specification: +24Vdc, 5mA) 10 Digital input terminals (Specification: +24Vdc) 8 Digital input terminals :
24 Digital input terminals (Specification: +24Vdc, 5mA)
Digital I/O 3 dedicated inputs for safety circuit (Support 110Vac or 110Vdc)
3 dedicated inputs for safety circuit (Support 110Vac or 110Vdc) Digital I/O 3 Digital output terminals (Specification: 0~24Vdc,
Specification: opto-coupler 0 to +30Vdc
50 input/output terminals with MCTC-KZ-D 0~50mA)
3 analog input terminals; 1 analog input terminal AI1: 0 to +10Vdc (optional)
Analog I/O 1 analog input terminal for load cell (Specification: -10 to +10Vdc) 1 analog input terminal for load cell (Specification: -10 to +10Vdc)
Analog I/O specification: AI1 & AI2 (0 to +10Vdc) & AI3( ±10Vdc )
2 analog output terminals;
specification: 0 to 10Vdc, 0 to 20mA
6 relay output terminals (250Vac/5A, 30Vdc/5A) with Onboard 21 relays, additional 7 relays with MCTC-KZ-D output
Relay programmable function terminals (250Vac/5A, 30Vdc/5A) with programmable function 2 relay output terminals (250Vac/3A, 30Vdc/1A) with 3 relay output terminals (250Vac/3A, 30Vdc/1A) with
Relay programmable function programmable function
2 CANbus (For Car Top Board and Duplex functions) 1 CANbus Port (For Duplex group control)
Communication CAN bus communication
1 Modbus (For Hall Call Board) Communication Modbus bus communication
N/A
● Optional encoder cards for PMSM (Gearless) ● Optional encoder cards for PMSM (Gearless)
i.MCTC-PG-E : Weton SinCos EI58C9.25/ERN1387 encoder with C,D signals, 5Vdc, i. MCTC-PG-E : Weton SinCos EI58C9.25/ERN1387 encoder with C,D
2048PPR signals, 5Vdc, 2048PPR
ii.MCTC-PG-F1 : Absolute SinCos ECN1313/ECN413 encoder with EnDat 2.0/2.1 ii. MCTC-PG-F1 : Absolute SinCos ECN1313/ECN413 encoder with EnDat Open Loop ●Incremental, +15Vdc Push-Pull/open collector output
Encoder Feedback serial communications, 5Vdc, 2048PPR 2.0/2.1 serial communications, 5Vdc,2048PPR ●General ABZ single-ended incremental encoder
iii.MCTC-PG-D : Quadrature incremental encoder (A+,A-,B+,B-) with UVW iii. MCTC-PG-D : Quadrature incremental encoder (A+,A-,B+,B-) with UVW Encoder Feedback
communication signals, 5Vdc, 8192PPR communication signals, 5Vdc,8192PPR (with closed loop vector control PM motor)
● Optional encoder cards for Induction motor (Geared)
● Optional encoder cards for Induction motor (Geared) i. MCTC-PG-A2 : Incremental encoders single ended (A,B signals, 12Vdc)
i.MCTC-PG-A2 : Incremental encoder single ended (A,B signals,12Vdc) ii. MCTC-PG-D : Quadrature incremental encoder (A+,A-,B+,B- signals, 5Vdc
ii.MCTC-PG-D : Quadrature incremental encoder (A+,A-,B+,B- signals, 5Vdc HTL) HTL)
Braking Unit Built-in (Up to 30kW) Built-in (Up to 30kW) Braking Unit Built-in N/A
1 2
Integrated Solution
3 4
Integrated Solution
NICE3000+ NICE 3000+
Basic Connection Diagram General Specifications
Standard 40-Floors Full Collective 380 to 480Vac 3 Phase Ratings (-15% to 10% : 3ØPh, 323Vac to 528Vac)
LANDING OPERATION PANEL (LOP) NICE3000+ Hot Pluggable Keypad Input Current Output Current
Motor Type Ty p i c al Di m en s i o n ( m m ) Dy n am i c Dy n am i c B r ak i n g R es i s t o r
Fr am e (A) (A)
Standard COP Feedback Type Mo d el C o d e Mo t o r B r ak i n g
Si ze Hei g h t Wi d t h Dep t h Recommended
Remote Keypad 3Ø 3Ø (k W) Un i t Mi n . Ω Max . Ω
(H) (W) (D) Power (W)
MCTC-MDKE
NICE-L-C/C1-4002 6.5 5.1 2.2 230 290 600
NICE-L-C/C1-4003 C 10.5 9.0 3.7 347 223 143 135 170 1,100
Weton SinCos E158C9.25/ERN1387 NICE-L-C/C1-4005 14.8 13.0 5.5 90 115 1,600
4x0.75mm2 Cable
MCTC-PG-E encoder with C,D signals
PM (Gear l es s ) NICE-L-C/C1-4007 20.5 18.0 7.5 65 85 2,500
NICE-L-C/C1-4011 D 29.0 27.0 11.0 347 223 174 In-Built 43 55 3,500
NICE-L-C/C1-4015 36.0 33.0 15.0 35 43 4,500
SinCos ECN1313/ECN413
MCTC-PG-F1 encoder with EnDat 2.0/2.1 NICE-L-C/C1-4018 41.0 39.0 18.5 25 34 5,500
E 350 210 192
NICE-L-C/C1-4022 49.5 48.0 22.0 22 24 6,500
NICE-L-C/C1-4030 62.0 60.0 30.0 16 20 9,000
OVE R L OAD
Quadrature incremental encoder F 400 250 220
(A+,A-,B+,B-) with UVW NICE-L-C/C1-4037 77.0 75.0 37.0 13 16 11,000
MCTC-PG-D commutation signals External
NICE-L-C/C1-4045 G 93.0 91.0 45.0 525 300 275 11 14 13,500
High Speed Bus 2
220 to 240Vac, -15% to 10% (187Vac to 264Vac)
High Speed Bus 1
Input Current Output Current Ty p i c al Dy n am i c B r ak i n g R es i s t o r
Di m en s i o n ( m m )
2x2x0.50mm2
8x0.75mm2 +
Dy n am i c
12x0.75mm2
(A) (A) Mo t o r
Flat Cable
Flat Cable
FF
A A
A
F
F
A
A D
D
Frame Reference (mm) Weight
FF
Size A B W H D (kg)
High Speed Bus 3
C 143 5.5
BH BB HH 150 335 223 347
H
B
OVE R L OAD
B
B H
H
D 174 7
Hall Call Board E 195 335 210 350 192 9.1
(MCTC-HCB-H) F 230 380 250 400 220 17
Car Call Board
5 (MCTC-CCB-A) Fr am e s i ze C, D Fr am e s i ze E , F Fr am e s i ze G G 245 523 300 525 275 35
4 *Level 17~40
3
2 Car Call I/O Name Designation Rules
1 *Level 1 to 16
OVE R L OAD
B1 ■Door Open NICE - L - X - XX XX - XX
><
■Door Close Encoder Type:
<> Attendant ■Door Open Delay Series
E i. Weton SinCos EI58C9.25
Independent
■Bypass Lift Solution ii. ERN1387 with C,D signals
Fireman
Direction Change Drive Mode iii. Quadrature incremental encoders (A+,A-,B+,B- signals, 5V HTL)
Lift Lock F1 i. ECN413 EnDat 2.0/2.1
Gearless/Geared (Synchronous/Asynchronous) C ii. ECN1313 EnDat 2.0/2.1
A2 i. Incremental encoders single ended (A,B signals,12V)
Geared (Asynchronous) C1 D i. Quadrature incremental encoders
Power Rating: (A+,A-,B+,B-) with communication signals
xx kW
Voltage Rating:
20: 220Vac
40: 380Vac
5 6
Integrated Solution
NICE 1000+ NICE 1000+
A simple and cost effective Integrated Solution for elevators speed up to 1.5 m/s General Specifications
Simplex and Duplex applications with closed loop geared and gearless PM machines Ambient Temperature Switching frequency 8kHz to 16kHz @ Max. 50℃ (24-Hour average maximum 45℃)
16 floors full collective using low cost conventional parallel wiring Installation Type New Elevators or retrofit existing Elevators (MR or MRL)
IP Rating IP 00
Smooth Ride Enhanced
Motor Control Synchronous (gearless) machines or induction (geared) machines
reliability with
conformal coating, Overload 150% for 60Sec, 200% for 1 sec
Design for
“ Direct To Floor” technology, protection against
Waiting time optimises high ambient Max. Speed ≤ 1.5 m/sec
humidity and
4-Independent S-Ramps temperature Group operation NEW Duplex on-board group control (CANbus 2-Wire)
Default factory setting makes user pollution dust
Wide operating 45℃avg
friendly, gets started quickly Max. floors ≤ 16 landings with conventional wiring (9 to16 landings require additional option board)
Anti-Rollback without any external load voltage range
Car wiring Conventional parallel wiring with binary or Grey or Seven segment display function
cell (Gearless Machine) 323 to 528Vac
Pre-torque function (Analog signal from Landing wiring Conventional parallel wiring with binary or Grey or Seven segment display function
load cell for Geared Machine)
In-Built Door operation mode 3 Selectable mode control (Manual, Semi-Auto, Auto)
Dynamic Emergency Evacuation operation 1-phase 230Vac UPS ready (Sine Waveform) with automatic Light load search
NEW Braking
Geared
Encoder Type Incremental encoders, singled ended (A,B signals 10-30V HTL).
Unit
Typically 1024PPR. Terminal block connector, internal mounting
Complies Quadrature incremental encoders (A+,A-,B+,B- signals, 5V HTL)
to EN81-1 To be advise by customer
Features Highlight
Gearless
by the time of order Weton SinCos EI58C9.25/ ERN1387 encoder with C,D signals
SinCos ECN1313/ECN 413 encoder with EnDat 2.0 serial communications
Quadrature incremental encoder (A+,A-,B+,B-) with UVW commutation signals
Standard 8 Floors full collective,
expansion option to 16 Floors NEW Flexible
NEW Static Auto-tuning without brake opening for Asynchronous and Synchronous
(Conventional Parallel Wiring) programmable NEW
Automatic Settings machines
Maximum speed 1.5m/sec NEW Selectable I/O connection
Duplex onboard group control NEW Elevator shaft position self-learning
Door Control
(CANbus serial communication)
Double digits 7-segment display NEW
Mode Rollback prevention at start
Pre-torque function (with an analogue signal from a load cell for geared machine)
Anti-rollback function (without any external load signal for gearless machine
(Parallel connection)
Selectable door control mode NEW
NEW Direct-To-Floor landing 3 dedicated inputs for safety circuit
(Manual, Semi-Auto, Auto)
Short floor travel without any necessary (Support 110Vac or 110Vdc)
Selectable Fireman operation NEW Conventional hardware or settings Flexible programmable inputs and
Synchronous (PM Gearless Machine) Double parallel wiring High stopping accuracy outputs
or Asynchronous (Geared Machine) digits 16-Floors Full Individual floor levelling adjustment Special Elevator test menu
Single-Phase 220V UPS rescue mode Additional features
7-Segment through COP Automatic ON/OFF cooling fan
operation ready with automatic light NEW Collective PC-Based software for easy fine-tuning
display Double Door control
load search Duplex Mode and software upgrade possibility Automatic light-load search for rescue
Comprehensive trip diagnostics onboard mode operation
Output frequency 0.0~100.0Hz
group
High ambient temperature ( 45℃avg )
control Designed to meet CE Certifications
St at i c A u t o - t u n i n g f o r a syn ch ro n o u s
*Technical file can be provide upon request
an d s yn ch ro n o u s m ach i n e(w i t h o u t EMC Directive 2004/18/EC EN 61800-3
b r ake o p en i n g ) NEW Product Conformity EN 55011
LVD Directive 2006/95/EC EN 61000-6-2
93/68/EEC EN 61800-5-1
Specification complies with EN81-1
Expansion I/Os
(MCTC-KZ-D)
Standard Base Unit to Expansion to 16 Floor
8 Floor Full Collective Full Collective
7 8
Integrated Solution
NICE 1000+ NICE 1000+
Basic Connection Diagram General Specifications
380 to 480Vac, -15% to 10% (323Vac to 528Vac)
Standard 8-Floors Full Collective, Expansion 16-Floors Full Collective
Input Current Output Current
LANDING OPERATION PANEL (LOP) NICE 1000+ Hot Pluggable Keypad Typical Dimension (mm) Dynamic Dynamic Braking Resistor
Frame (A) (A)
Motor Type Model Code Motor Braking
Expansion Standard COP Feedback Type Size Height Width Depth Recommended
3Ø 3Ø (kW) Unit Min. Ω Max. Ω
(H) (W) (D) Power (W)
Remote Keypad
MCTC-MDKE NICE-L-H/H1-4002-XX 6.5 5.1 2.2 230 290 600
Expansion I/Os NICE-L-H/H1-4003-XX C 10.5 9.0 3.7 347 223 143 135 170 1,100
(MCTC-KZ-D)
NICE-L-H/H1-4005-XX 14.8 13.0 5.5 90 115 1,600
Weton SinCos E158C9.25/ERN1387
NICE-L-H/H1-4007-XX 20.5 18.0 7.5 65 85 2,500
MCTC-PG-E encoder with C,D signals
PM (Gearless) NICE-L-H/H1-4011-XX D 29.0 27.0 11.0 347 223 174 In-Built 43 55 3,500
22 x 0.75mm 2 NICE-L-H/H1-4015-XX 36.0 33.0 15.0 35 43 4,500
Flat Cable
2x [ 12 x 0.75mm 2 ]
1Ø 3Ø 1Ø 3Ø Unit
MCTC-PG-A2 (A, B signals) 1Ø 3Ø (H) (W) (D) 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø
Flat Cable
Flat Cable
NICE-L-H/H1-2002-XX 9.2 11.0 5.2 9.6 1.1 2.2 125 65 145 72 300 600
C 347 223 143
NICE-L-H/H1-2003-XX 13.3 17.0 7.5 14.0 1.5 3.7 90 50 105 54 450 1,100
Induction (Geared)
Quadrature Incremental encoders NICE-L-H/H1-2007-XX 17.9 20.5 10.3 18.0 2.2 4.0 63 35 72 40 600 1,200
MCTC-PG-E (A+,A-,B+,B- signals, 5V HTL) NICE-L-H/H1-2011-XX D 25.3 29.0 15.5 27.0 3.7 5.5 347 223 174 37 25 43 29 1,100 1,600
20 x 0.75mm 2 In-Built
20 x 0.75mm 2 Flat Cable
Flat Cable NICE-L-H/H1-2015-XX 31.3 36.0 19.0 33.0 4.0 7.5 35 22 40 26 1,200 2,500
NICE-L-H/H1-2018-XX 34.6 41.0 22.5 39.0 5.5 11.0 25 13 29 15 1,600 3,500
15 x 0.75mm 2
15 x 0.75mm 2 Flat Cable
E 350 210 192
Flat Cable NICE-L-H/H1-2022-XX 42.6 49.0 27.7 48.0 11.0 15.0 16 13 18 13 3,500 4,500
NICE-L-H/H1-2030-XX F 52.6 62.0 34.6 60.0 15.0 18.5 400 250 220 13 12 13 13 4,500 5,500
Dimensions
W
W
DD W
W
D
D W
W
A
A A
A A
A D
D Reference (mm)
FF
FF
F
F
Frame Weight
Size A B W H D (kg)
C 143 5.5
BH BB HH 150 335 223 347
H
B
B
B H
H
D 174 7
7
E 195 335 210 350 192 9.1
3
6 F 230 380 250 400 220 17
2
5 G 245 523 300 525 275 35
1 Frame size C, D Frame size E , F Frame size G
4
13 x 0.75mm 2
G Name Designation Rules
13 x 0.75mm 2
Flat Cable
Flat Cable
NICE - L - X - XX XX - XX
Encoder Type:
Series
E i. Weton SinCos EI58C9.25
Lift Solution ii. ERN1387 with C,D signals
Drive Mode iii. Quadrature incremental encoders (A+,A-,B+,B- signals, 5V HTL)
F1 i. ECN413 EnDat 2.0/2.1
Gearless/Geared (Synchronous/Asynchronous) H ii. ECN1313 EnDat 2.0/2.1
A2 i. Incremental encoders single ended (A,B signals,12V)
Geared (Asynchronous) H1 D i. Quadrature incremental encoders
Power Rating: (A+,A-,B+,B-) with UVW communication signals
xx kW
Voltage Rating:
20: 220Vac
40: 380Vac
9 10
Escalator Solution
Escalator will accelerate to quick speed and keep quick speed operation when passengers
Quick-stop cycle mode enter the entrance.
Escalator will decelerate to stop in idle.
Escalator will accelerate to quick speed and keep quick speed operation when passengers
Quick-slow cycle mode enter the entrance.
Escalator will decelerate to low speed and keep low speed operation in idle.
Escalator will accelerate to quick speed and keep quick speed operation when passengers
enter the entrance.
Quick-slow-stop cycle mode
Escalator will decelerate to low speed and keep low speed operation in idle.
If the idle status keeps a long time, escalator will decelerate to stop.
General Specifications
380 to 480Vac, 3-Phase (-15% to 10%,323Vac to 528Vac)
Dimension(mm)
NICE2000 has been designed as a Input Current Output Current Typical Motor
Model Code Capacity (kVA) (A) (A) (kW)
simple and cost effective variable Height (H) Width (W) Depth (D)
speed integrated controller that NICE-E1-A-4013 8.9 14.6 3 5.5 248.0 160.0 183.0
delivers ultimate performance and
NICE-E1-A-4017 11.0 20.5 17.0 7.5
flexible capability for escalators.
NICE-E1-A-4025 17.0 26.0 25.0 11.0 322.0 208.0 192.0
11 12
Escalator Solution Elevator Solution
MCTC-PES-E1 ME320LN for Elevator
In China, the safety standard for escalators was
Programmable Electronic Systems also revised as GB 16899-2011, which
Closed Loop Inverter
in Safety Related Applications incorporates almost all of the regulations of EN
115-1:2008+A1:2010 and went into effect in
for Escalators July 2012.
To fulfill the requirement of the Chinese market,
Monarch has developed an product (MCTC- ME320LN is a dedicated inverter for
PES-E1) to enhance safety that is complaint
elevator control, with specific parameter
with GB 16899-2011 standard, including the
newly introduced PESSRAE regulation. set and features that are tailored for easy
integration in elevator controllers
MCTC-PES-E1 Comply With
■ GB16899-2011: Safety Specification of escalator
and moving walk produce and installation
■ GB/T20438-2006: Functional safety of safety-
related electrical, electronic and programming Power Rating
electronic control system ■ 2.2kW to 45kW, three-phase 380 to 480Vac
PESSRAE: Programmable Electronic ■ IEC62061: 2005: Safety of machinery-
Systems in Safety Related Applications for Functional safety of safety- related electrical Applications
electronic and programming electronic control ■ Elevator
Escalators and moving walkway regulation system
for Chinese Market. In the field of ■ ISO22201: 2009: Lifts (elevator)- Design and Applicable Motor Type
development of programmable electronic ■ Asynchronous (Induction) motor Technical Features
escalators, there is a strong social systems in safety –related applications for lifts ■ Synchronous Permanent Magnet Motor ■ Smooth starting and stopping performance without load
requirement for high safety to protect (Pressral) compensations (Gearless)
■ EN115-1: 2008+A1: 2010: Safety of escalations Applicable Encoder Type ■ Pre-torque function (Analog signal from load cell for
users and others from danger, as well as and moving walks ■ MDPG-C(terminal block) / MDPG-C2(15-Way Geared Machine)
an increasing focus on energy D-Sub) for Weton SinCos EI58C9.25/ERN1387 ■ Flexible and enhanced S-Ramps (4-Independent)
(5Vdc, 2048PPR) encoder with C,D signals and allows fine-tuning of ride performance
conservation in recent years. In particular, Others Features quadrature incremental encoder (A+,A-,B+,B- ■ UPS rescue light-load search for elevator rescue
the European safety standard for ■ Engineering unit for speed monitor ( x.x m/sec) signals, 5V HTL Compatible) application
■ MD32PG5 for absolute SinCos ECN413/ECN1313 ■ Dedicated elevator control features like integrated
■ Engineering unit braking distance monitor (x.xx m)
escalators has been revised as EN with EnDat2.0/2.1 brake control interface with elevator running logic,
■ Up to 5 faults log history record ■ MDPG-B for quadrature incremental encoder overload protection and 40 trip indications to facilitate
(European Norm) 115-1:2008+A1:2010, ■ Pulse interval number monitoring (A+,A-,B+,B-) with UVW commutation signals easy diagnostics etc.
with the addition of a significant number of ■ Control system states monitoring ■ MDPG-A4 for incremental encoder single ended ■ Get started quickly with user friendly default factory
■ Interface friendly with escalator controller & inverter (A+,B+ signals) setting
safety-related regulations.
■ Remote keypad (Optional)
■ Long life design (MTTF 15 years)
Di g i t al I n p u t /Ou t p u t
General Specifications
MCTC-PES-E1
Brake &Safety Limit Sensor/Switch/Button 380 to 480Vac, -15% to 10% (323Vac to 528Vac)
Switch Speed measured
by the driving chain
sprocket
Input Current Output Current Typical Dimension, (mm) Dynamic Dynamic Braking Resistor
Step guide
Movable comb plate LED Display Tachometer Model Code Frame Size (A) (A) Motor Braking
Min. Ω Max. Ω Recommended
Comb plate support Inductive part
Combs Fixed comb plate L B Sensor B wheel
Sensor 3/4 Height Width Depth
Handrail
3Ø 3Ø (kW) Unit
Sensor A (H) (W) (D) Power (W)
LA L3/4
Push rod
Safety switch
Sensor 3/4 ME320LN-4002-SA C 5.8 5.1 2.2 186 125 164 220 290 600
Cover plate Sensor A signal
Sensor 3/4 signal
ME320LN-4003-SA 10.5 9.0 3.7 130 170 1,100
Compression spring
D 248 160 183
Sensor B signal
ME320LN-4005-SA 14.6 13.0 5.5 90 115 1,600
ME320LN-4007-SA 20.5 18.0 7.5 65 85 2,500
ME320LN-4011-SA E 29.0 27.0 11.0 322 208 192 In-Built 43 55 3,500
ME320LN-4015-SA 36.0 33.0 15.0 32 43 4,500
L5/L6
Switch/Button ME320LN-4018-SA 41.0 39.0 18.5 25 34 5,500
Optional Step beam to
Step/Pallet loss be detected
Mot or sensor 5/6
ME320LN-4022-SA F 49.5 48.0 22.0 432 285 228 22 24 6,500
Sensor 5/6
ME320LN-4030-SA 62.0 60.0 30.0 16 20 9,000
L5/L6
Step
Sensor 5/6 signal
ME320LN-4037-SA 77.0 75.0 37.0 13 16 11,000
NICE2000 G 549 385 265 External
ME320LN-4045-SA 93.0 91.0 45.0 11 14 13,500
MCTC-TBB-A
DOL Bypass Unit
Di g i t al I n p u t /Ou t p u t
13 14
Elevator Solution
Dr i v e In p u t
Rated Input Voltage
Elevator Application Features Operation in Wide (170Vac to 264Vac) (323Vac to 500Vac)
high ambient operating Rated Input Current, [ A ] 10.5 14.6 26 35 10.5 14.6 20.5 26 35
Dr i v e Ou t p u t
Output Current, [ A ] * 9 13 25 32 9 13 17 25 32
4-Independent S-Ramps
Programmable DC-injection braking Power Capacity, [ k VA ] 5.9 8.9 17 21 5.9 8.9 11 17 21
Res i s t o r
B r ak i n g
easy start up Power, [ W] **
500 750 1200 1500 750 1200 1500 2500 3000
Recommended
≥ 65 ≥ 45 ≥ 22 ≥ 16 ≥ 130 ≥ 90 ≥ 65 ≥ 43 ≥ 32
Resistance, [Ω ]
Enclosure IP 21
Enhanced
General Connection Diagram
reliability with
conformal coating, External Braking Resistor (To be supplied by Optional)
2
protection against 1
humidity and
Output Contactor
pollution dust R L1
PB
U
Travel Up D I1
start up & COM
Travel Down D I2 Safety Circuit
backup DO1
DI9
15 16
Integrated Solution
NICE900
Door Machine Integrated Controller Elevator, Escalator control cabinet
NICE900 is a compact, simple to
use and cost effective integrated Comprehensive & cost effective elevator and escalator control cabinets are
controller specially designed for available for customers who require more than standard, ready-to-mount inverter.
various car door controls such as
elevator door and subway car
door. It drives both asynchronous
and synchronous motor (without
encoders) and supports speed
control mode and distance
controlmode (with encoders).
Physical Dimensions:
NICE - D - A - S OP2
66
Motor Power
OP2: 200W
2-Ø5
197 NICE Series OP4: 400W Elevator Control Cabinet Machine Room-less Integrated
Mo narc h
Dedicated Door Drive
OP7: 750W Control Cabinet
128. 8
147
Voltage Rating:
Housing Enclosure Type
S: Single Phase 220V
2-6.5* 5
A: Plastic
204. 7 For more information, please contact our local offices.
1. NICE-D-A-SOP2: 0.2kW
2. NICE-D-A-SOP4: 0.4kW
3. NICE-D-A-SOP7: 0.75kW
220 to 240Vac Single Phase Drive Ratings, -15% to 10% (187Vac to 264Vac)
Input Current Output Current Nominal Power Output Voltage Output Frequency
Model (A) (A) (W) (V) (Hz)
17 18
Integrated Solution
ACCESSORIES
Compatibility
A wide range of optional cards and accessories are available for users to integrate with existing
elevator system andother vender supplier equipments. Item Model No Description NICE3000+ NICE1000+ NICE900 MD380L
Compatibility
Function Configuration:
Through-Door open control, analogue torque
LED Remote Keypad Hot pluggable, high-brightness 5-Digits LED display compensation, over-load signal, full-load signal,
Model No.: keypad, show parameters of running speed, bus voltage
√ Model No:
bidirectional arrival chime signal, serial-link with car display
√
MCTC-MDKE etc. Allows user for parameter set up & maintenance. board and command button
MCTC-CTB-B
(Vertical connector)
Hardware Configuration:
5Vdc Supply, female 15-way D-type connector
Hardware Configuration:
24 digital input terminals, 20 digital output terminals
Function Configuration:
SinCos Encoder Card
Model No:
MCTC-PG-E
Weton SinCos EI58C9.25/ERN1387 encoder with C,D
signals. Fitted to main control board. For Gearless PM
Motor.
√ Car Call Board
Model No:
MCTC-CCB-A
Function Configuration:
16 Floor buttons and 8 functional signals. e.g. : Door √
OPEN/CLOSE, door open delay, non-stop mode ,
attendant mode, reversing direction, independent mode,
Quadrature incremental encoders (A+, A-, B+, B- signals,
fireman mode, arrival gong signal output.
5VHTL). Fitted to main control board. For Geared motor.
Hardware Configuration:
12Vdc Supply, terminal block connector Arrival voice synthesizer
Asynchronous encoder card, Model No:
MCTC-CHM-B
Allows user to preset standard messages and announce to
the passenger by a voice synthesizer √
Terminal block
Model No:
MCTC-PG-A2
Function Configuration:
For incremental encoder, single ended (A, B). Fitted to √
main control board. Fitted to main control board. For
Geared motor.
To facilitate for advanced door-open function. When the lift
is running automatically and the speed is slower than
√ √
Advanced Door Open Board 0.3 m/sec in the stopping cycle and the door-zone signal is
Model No: valid, SCB-A shorts the door lock signal through the
MCTC-SCB-A advanced door-open contactor, and pre-opens the door
External Braking Unit thereby enhancing the efficiency.
Model : No External braking unit for integrated controller rating above 30kW
MDBU-35A/B/C/D,
MDBU-70A/B/C/D,
Input voltage:220Vac, 380Vac, 440Vac, 460Vac, 690Vac
(Remarks: In-built braking unit for integrated controller ≤ 30kW)
√
MDBU-200A/B/C/D/E
Software Characteristic:
Access Rights Login, offers control over individual car,
ability to view lift controller system version, travel counts,
Hardware Configuration:
ability to upload and download parameters value of the lift
controller and drive, real-time elevator current condition
√ √
1 group of RS232, 1 group of RS485, 4 groups of CAN and information to expedite troubleshooting and reduce
communication port, operational panel circuit
downtime
Group Control Board Function Configuration:
Model No: Minimum wait time basis allocation mode, efficiency
MCTC-GCB-A preference mode based on fuzzy logic control, password
protection, group control home landing setting, peak
service, energy-saving, re-enforce simplex-mode over
group control, service floor and separate wait function.
For 3~4 elevators coordination (for duplex-standard inbuilt
for NICE 3000+
19 20
Integrated Solution
ACCESSORIES
Compatibility Compatibility
Item Model No Description NICE3000+ NICE1000+ NICE900 MD380L Item Model No Description NICE3000+ NICE1000+ NICE900 MD380L
Hardware configuration:
Hall Call Board, Vertical 4.3" inch vertical dual colour LCD. Blue background with white
Model No: letters.
MCTC-HCB-H
(Red colour dot-matrix)
MCTC-HCB-H1 √
Model No:
MCTC-HCB-U1
Appearance size:
144mm x 80mm x 16.9mm
√
(Blue colour dot-matrix) Hardware Configuration:
MCTC-HCB-H2 5x7 high contrast dot-matrix LED display, 1 over/full load Display area:
(Amber colour dot-matix) illuminant block, 4 digital inputs/outputs 92mm x 54mm
Function Configuration:
Travel UP & DOWN button indicator output, directional Hardware configuration:
Hall Call Board, Horizontal dot-matrix output, over-load indicator, double button control, 6.4" inch vertical dual colour LCD. Blue background with white
Model No.: hall call button input, fire emergency input, lock input letters.
MCTC-HCB-F
(Red colour dot-matrix)
MCTC-HCB-F1 √
Model No:
MCTC-HCB-V1
Appearance size:
185mm x 131mm x 18mm √
(Blue colour dot-matrix)
MCTC-HCB-F2 Display area:
(Amber colour dot-matrix) 139mm x 99mm
Hardware configuration:
Hall Call Board, Vertical
4.3" inch TFT LCD Display, Resolution: 480 x 272 pixels
Model No.:
MCTC-HCB-XG-INT-VX
(Amber colour dot-matrix)
Hardware Configuration:
16x16 high contrast dot-matrix LED display, double arrow
indicator, 1 over/full load illuminant block, 4 digital
√ Model No:
MCTC-HCB-T1 Function configuration: √
Vertical display, content NOT editable with TPPS-MNK software
inputs/outputs
Function Configuration:
Travel UP & DOWN button indicator output, directional
dot-matrix output, over-load indicator, double button control,
hall call button input, fire emergency input, lock input & hall Hardware configuration:
Hall Call Board, Horizontal
7" inch TFT LCD Display, Resolution: 1024 x 768 pixels
√
Model No.: lantern
MCTC-HCB-XG-INT-HX
(Amber colour dot-matrix)
Model No:
MCTC-HCB-T2 Function configuration:
Vertical/horizontal display, each with two different type styles,
√
adjustable display content with TPPS-MNK software
Hardware Configuration:
5x7 high contrast dot-matrix LED display Hardware configuration:
Ultra-Thin Floor Call Board
4 digital inputs/outputs 9.7" inch TFT LCD Display, Resolution: 1024 x 768 pixels
(Red LED)
Model No:
MCTC-HCB-R2 Function Configuration:
√
Model No:
MCTC-HCB-T3 Function configuration:
Vertical/horizontal display, each with two different type styles,
√
(Red colour dot-matrix) Travel UP & DOWN button indicator output, directional
adjustable display content with TPPS-MNK software
MCTC-HCB-R2 dot-matrix output, over-load indicator, double button
(Amber colour dot-matrix) control, hall call button input, fire emergency input, lock
input
Mechanical Specifications:
Hardware Configuration: Rotating speed ≤ 2,000 rpm, starting torque 1x10^2 N.m
Full Dot Matrix Hall Call Board Axial load 10N, Radial load 10N
Model No: 16x24 high contrast dot-matrix LED display
Weton SinCos Encoder
√ √
MCTC-HCB-G1 4 digital inputs/outputs
(Red colour dot-matrix)
MCTC-HCB-G2 Function Configuration:
√ Model No.:
EI58C9.25-2048
Electrical Specification:
Supply Voltage : 5Vdc (±5%)
Travel UP & DOWN button indicator output, directional No load current : ≤ 100mA
(Amber colour dot-matrix)
dot-matrix output, over-load indicator, double button control, Frequency response : ≤ 50kHz
hall call button input, fire emergency input, lock input Resolution : 2,048PPR
Mechanical Specifications:
Hardware Configuration: Hole Diameter : 30~45 mm,
Dual 5x7 high contrast dot-matrix LED display Shaft Loading : up to 10N axial and 10N radial,
Hall Call Board
Model No.: Starting torque at (25ºC) : 5x10^3Nm
MCTC-HCB-Y1
(Amber colour dot-matrix)
Function Configuration:
For duplex elevator group control
Travel UP & DOWN button indicator output, directional
√ Weton Rotary Incremental
Maximum RPM : 5,000
Moment of inertia : 980m/s^2
√ √
NPN Voltage output type
Model No.:
E3S-GS3B4 (PNP Output)
Environmental Specifications :
E3S-GS3E4 (NPN Output)
Operating temperature : 0 to +80ºC
Storage temperature : -20 to +80ºC