Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division MSC0213
GENERAL
INFORMATION
SECTION CONTENTS:
Representatives
Recommended Long Term Storage
Approximate Controller Shipping Weights
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 2
METRON SERVICE REPRESENTATIVES
ALABAMA Cybertronic Coatings LLC CONNECTICUT
1905 West Thomas Street Walter E. Dawson
Suite D-181 dba E J Enterprises
Hammond, LA 70401 33 Bartlett Loop
(985) 351-5681 Warner, NH 03278‑4500
Mr. Glenn Bradshaw (603) 456‑3014
Fax (603) 456‑3013
ALASKA Metron, Inc. Mr. Walt Dawson
1505 W. Third Avenue
Denver, CO 80223 DELAWARE GDS Controls
(303) 592‑1903 5301 Carlisle Road
Fax (303) 534‑1947 Dover, PA 17315
Service Department (717) 292‑9403
Fax (717) 292‑5746
ARIZONA Ken Cramer Co. Mr. Dave Stephens
4733 Torrance Blvd. #296
Torrance, CA 90503 DISTRICT OF COLUMBIA
(310) 375‑6356 GDS Controls
Fax (310) 375‑6356 + 5301 Carlisle Road
Mr. Tom Stolarski Dover, PA 17315
(717) 292‑9403
ARKANSAS J.A. Controls Inc. Fax (717) 292‑5746
13118 Suzanne Mr. Dave Stephens
Stanford, TX 77477
(281) 530‑2500 FLORIDA Horton & Company
Fax (281) 530‑9202 Tampa & 3421 San Jose Street
Mr. Jim Adams Central Tampa, FL 33629
(813) 871‑2393
CALIFORNIA Fax (813) 839-3292
Northern Control Central, Inc. Mr. Lee Horton
12 La Serena Court Mr. Bob Horton
Alamo, CA 94507
(925) 743‑8994 Southern Metron, Inc
Fax (925) 743‑8437 1505 W. Third Avenue
Mr. Kenneth Pearce Denver, CO 80223
(303) 592‑1903
Southern Ken Cramer Co. Fax (303) 534‑1947
4733 Torrance Blvd. #296 Service Department
Torrance, CA 90503
(310) 375‑6356 Panhandle Cybertronic Coatings LLC
Fax (310) 375‑6356 + 1905 West Thomas Street
Mr. Tom Stolarski Suite D-181
Hammond, LA 70401
COLORADO Metron, Inc. (985) 351-5681
1505 W. Third Avenue Mr. Glenn Bradshaw
Denver, CO 80223
(303) 592‑1903 GEORGIA Aqua Flow Service
Fax (303) 534‑1947 4220 Steve Reynolds Blvd, Suite 16
Service Department Norcross, GA 30093
(770) 935‑8443
Fax (770) 935‑8443
Mr. James Girsch
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 3
METRON SERVICE REPRESENTATIVES
HAWAII Introl Hawaii, Inc. KANSAS Custom Enterprises
2020 A Kahai Street 93 10 Wenonga
Honolulu, HI 96817 Leawood, KS 66206
(808) 845‑7471 (913) 383‑2545
Fax (808) 847‑2734 Mr. Dick Kerr
Mr. Les Lum
KENTUCKY Metron, Inc.
IDAHO Metron, Inc. 1505 W. Third Avenue
1505 W. Third Avenue Denver, CO 80223
Denver, CO 80223 (303) 592‑1903
(303) 592‑1903 Fax (303) 534‑1947
Fax (303) 534‑1947 Service Department
Service Department
LOUISIANA Cybertronic Coatings LLC
ILLINOIS 1905 West Thomas Street
North‑ Metron, Inc. Suite D-181
Southeast 3600 Woodgate Drive Hammond, LA 70401
Wheatfield, IN 46392 (985) 351-5681
(219) 765-7645 Mr. Glenn Bradshaw
Fax (219) 956-2788
Dana Everett
MAINE Walter E. Dawson
Southwest Custom Enterprises dba E J Enterprises
93 10 Wenonga 33 Bartlett Loop
Leawood, KS 66206 Warner, NH 03278‑4500
(913) 383‑2545 (603) 456‑3014
Mr. Dick Kerr Fax (603) 456‑3013
Mr. Walt Dawson
Northwest Metron, Inc.
3600 Woodgate Drive MARYLAND GDS Controls
Wheatfield, IN 46392 5301 Carlisle Road
(219) 765-7645 Dover, PA 17315
Fax (219) 956-2788 (717) 292‑9403
Dana Everett Fax (717) 292‑5746
Mr. Dave Stephens
IOWA East Metron, Inc.
3600 Woodgate Drive MASSACHUSETTS
Wheatfield, IN 46392 Walter E. Dawson
(219) 765-7645 dba E J Enterprises
Fax (219) 956-2788 33 Bartlett Loop
Dana Everett Warner, NH 03278‑4500
(603) 456‑3014
IOWA West Custom Enterprises Fax (603) 456‑3013
93 10 Wenonga Mr. Walt Dawson
Leawood, KS 66206
(913) 383‑2545 MICHIGAN
Mr. Dick Kerr So. Central Metron, Inc.
1505 W. Third Avenue
Denver, CO 80223
(303) 534‑1947
Fax (303) 592‑1903
Service Department
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 4
METRON SERVICE REPRESENTATIVES
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 5
METRON SERVICE REPRESENTATIVES
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 6
METRON SERVICE REPRESENTATIVES
VIRGINIA
Southern E. H. Walters & Assoc.
4303 Tabernacle Rd.
Lancaster, SC 29720
(803) 286‑4777, Fax same
Mr. Eustice Walters
Mr. Van Walters
WASHINGTON
Metron, Inc.
1505 W. Third Avenue
Denver, CO 80223
(303) 592‑1903
Fax (303) 534‑1947
Service Department
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 7
METRON INTERNATIONAL SERVICE REPRESENTATIVES
Brazil Egypt
Sao Paulo Arabian Engineering Business (AEB)
Coenger Comercio, Engenharia Ltda. Metron Fire Pump Controllers UL/FM
Ing. Luiz Alberto Benedetti Clarke Fire Engine UL/FM
Ing. Joao de Moraes Barbosa Middle East Sole Agent
Rua Martim Bruchard, 310 #12 Khalil Kamel St. Heliopolis, Cairo
Sao Paulo, CEP 03043-020 Cell: +2 010 05312374, 01229979993
Brazil Work: + 202-2634 1296
E-Mail: coenger@ig.com.br E-Mail: aebpumps@gmail.com
Tel: 55 11 5571 4867 aebpumps@hotmail.com
Fax: 55 11 3209 1384
Cell: 55 11 9761 8003
Chile Israel
Macam Ltda E. Shlomi Services
Ing. Carlos Sarquis Eliezer Shlomi
Aracena Infanta No 188 Gonot 73
San Joaquin Israel 50293
Santiago, Chile Tel: 972 3 690 4260
Email: commacam@entelchile.net Fax: 972 3 960 4327
Tel: 56 2 555 0959
Fax: 56 2 556 1397
United Arab Emirates
Mexico Alaman
SKMOL TECHNOLOGY SA DE CV Mr. Qais Khader
Ing. Gustavo Balboa Dubai- UAE
5 de Mayo Sur No. 212A Tel: 971-4 2580090
Apodaca Centro Fax: 971-4-2580098
N.L. Mexico CP 66600
www.skmol.com.mx
E-Mail: gustavo.balboa@skmol.com.mx Bawabat Al Aman Security and Safety
Tel: 52 (81) 1877 25 73 Amro Ibrahim Sayed Abou Salem
Cell: 52 (81) 1577 79 31 Dubai, UAE
E-mail:
ASIA Tel: +971-501-605510
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 8
METRON
It is recommended that controllers be inspected upon receipt at job or storage facility for any damage that may
have incurred during shipment.
Metron should be notified of any long term storage requirements, so the controllers can be shipped in plywood
crates (completely enclosed). It is recommended that the controller be returned to its crate after inspection,
resealed and stored in an environmentally controlled atmosphere (room temperature) free of moisture, splashing
liquids or dust.
It is also recommended when controllers are to be stored in excess of two (2) months that a moisture inhibitor
(desiccant) be installed in various points within the shipping crate and replaced periodically.
Prior to installation, another visual inspection should be made to insure that moisture or excessive dirt is not
present within the controller.
When installing conduit for wiring, extra care should be taken to insure that metal particles, cut wires, etc. do not
fall into any of the components.
Should a Metron serviceperson be required for repair due to inadequate storage or handling, the customer will
assume all expenses for PARTS, FOOD, LODGING along with STANDARD SERVICE DEPARTMENT
LABOR CHARGES for repair.
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 9
METRON CONTROLLER SHIPPING WEIGHTS
Weight with
Weight Transfer Switch
Controller Model Pounds Kilograms Pounds Kilograms
FD4 193 88
FD4 with legs 220 100
MP600 1210 549
M15 Jockey Pump 42 19
M30 (limited service) 180 82 404 183
MP300
208VAC up to 75 HP 248 112 407 185
380VAC up to 125 HP 248 112 407 185
460VAC up to 125 HP 248 112 407 185
208VAC 100-150 HP 365 166 703 319
380VAC 150-300 HP 365 166 703 319
460VAC 200-400 HP 365 166 703 319
208VAC 200-250 HP 496 225 768 348
380VAC 350 HP 496 225 768 348
460VAC 500 HP 496 225 768 348
MP400
208VAC up to 75 HP 298 135 450 204
380VAC up to 125 HP 298 135 450 204
460VAC up to 125 HP 298 135 450 204
208VAC 100-150 HP 415 188 743 337
380VAC 150 HP 415 188 743 337
MP420
208VAC up to 75 HP 288 131 438 199
380VAC up to 125 HP 288 131 438 199
460VAC up to 125 HP 288 131 438 199
208VAC 100-150 HP 395 179 746 338
380VAC 150-300 HP 395 179 746 338
460VAC 200-400 HP 395 179 746 338
208VAC 200-250 HP 553 251 NA NA
380VAC 350 HP 553 251 NA NA
460VAC 500 HP 553 251 NA NA
MP430
208VAC up to 75 HP 302 137 468 212
380VAC up to 125 HP 302 137 468 212
460VAC up to 150 HP 302 137 468 212
208VAC 100-150 HP 409 186 575 261
380VAC 150-300 HP 409 186 575 261
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 10
METRON CONTROLLER SHIPPING WEIGHTS
Weight with
Weight Transfer Switch
Controller Model Pounds Kilograms Pounds Kilograms
460VAC 200-400 HP 409 186 575 261
208VAC 200-250 HP 573 260 930 422
380VAC 300-400 HP 573 260 930 422
460VAC 500 HP 573 260 930 422
MP435
208VAC up to 75 HP 342 155 509 231
380VAC up to 125 HP 342 155 509 231
460VAC up to 150 HP 342 155 509 231
208VAC 100 HP 449 204 557 253
380VAC 150 HP 449 204 557 253
460VAC 200 HP 449 204 557 253
208VAC 125-150 HP 573 260 658 298
380VAC 200-300 HP 573 260 658 298
460VAC 250-450 HP 573 260 658 298
208VAC 200-250 HP 641 291 882 400
380VAC 350-400 HP 641 291 882 400
460VAC 500 HP 641 291 882 400
MP450
208VAC up to 20 HP 352 160 518 235
380VAC up to 40 HP 352 160 518 235
460VAC up to 50 HP 352 160 518 235
208VAC 25-75 HP 385 175 567 257
380VAC 50-125 HP 385 175 567 257
460VAC 60-150 HP 385 175 567 257
208VAC 100 HP 452 205 623 283
380VAC 150-200 HP 452 205 623 283
460VAC 200-250 HP 452 205 623 283
208VAC 125-150 HP 750 340 984 446
380VAC 250-300 HP 750 340 984 446
460VAC 300-400 HP 750 340 984 446
MP700
208VAC 15-75 HP 365 166 527 239
380VAC 15-125 HP 365 166 527 239
460VAC 15-150 HP 365 166 527 239
208VAC 100-150 HP 624 283 796 361
380VAC 150-300 HP 624 283 796 361
460VAC 200-400 HP 624 283 796 361
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 11
DIESEL
ENGINE
CONTROLLERS
Contents:
SECTION CONTENTS:
FD4 Bulletin
FD4 Price Sheets
Model Drawings
FD4 FD4 - Diesel Driven Fire Pumps
Liquid Level Switch, AA10519E
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 12
Fire Pump Controller
For Diesel Driven Fire Pumps
Series FD4
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 14
FUEL SPILL LOW PURGE PRESSURE Controller Operation
FUEL TANK RUPTURE LOW GEAR OIL PRESSURE Automatic Mode:
LOW PUMP ROOM TEMP LOW COOLANT LEVEL Starting conditions such as pressure drop, and deluge valve start,
RESERVOIR LOW HIGH GEAR OIL TEMP will cause the user adjustable sequential start delay timer to begin
RESERVOIR EMPTY HIGH VIBRATION operation. After start delay is completed the engine will start and
RESERVOIR HIGH LOW FUEL PRESSURE the operation will be recorded in the event log. In addition to the
FLOW METER ON HIGH EXHAUST TEMP sequential start timer the Automatic Weekly Test Start, AC Power
RELIEF VALVE OPEN HIGH FUEL TEMP Fail Start are programmable by the user through the OlD. All
LOW SUCTION PRESSURE PUMP ON DEMAND system statistics are continuously monitored and changes are
logged into the internal logs. System statistics include, but are not
Data logging: limited to, battery charger volts/amps, battery voltage, and system
Pressure Log: The Pressure log provides a continuous pressure pressure are continuously monitored and changes are logged.
recording for one month of data. Each time the pressure log
records a pressure it includes the time and date of the reading and Stopping conditions: Auto engine stop delay, engine lockout, low
is stored on the SD memory card. suction shutdown, automatic stop during automatic weekly test for
low oil pressure and high water temperature are all OlD user
The data recorded in the pressure log can be searched by each programmable features.
sample, by minute, or by hour allowing for easy access to specific
data. Manual Mode:
If a control logic failure occurs, two crank pushbuttons are provided
Event Log: The event log is also stored on the SD memory card. It that will bypass all internal logic and allow manual operation of the
will hold a maximum of 3000 events. These events include any of engine.
the following events/alarms:
BATTERY 1 FAULT
BATTERY 2 FAULT
SYSTEM AUTO MODE
ENGINE LOCKOUT SIGNAL
Options
BATTERY 1 LOW VOLTAGE SYSTEM AUTO MODE Option H: Space Heater
BATTERY 2 LOW VOLTAGE SYSTEM MANUAL MODE If the ambient atmosphere is especially damp or humid, a space
CHARGER 1 FAULT SYSTEM OFF MODE heater rated at 100 watts may be supplied to reduce moisture in the
CHARGER 2 FAULT SYSTEM TEST RUN cabinet. A thermostat is supplied as standard with this option. A
AC POWER FAIL ALARM RESET humidistat may be substituted at no additional charge.
ENGINE OVERSPEED LOW PRESSURE CONDITION
ENGINE FAILED TO START LOW PRESSURE START Option N: Step-down Transformer
ENGINE QUIT DELUGE START When AC voltage exceeds 240 VAC single phase, an integral
ENGINE LOW OIL PRESSURE REMOTE START transformer may be provided for operation from 380 to 600 VAC
ENGINE HIGH WATER TEMP AC POWER FAIL START 50/60 Hz input. Exact voltage and frequency must be specified
PRESSURE DROP HORN SILENCED when ordering.
STOP PUSHBUTTON PRESSURE TRANSDUCER Option W: 24 Inch (609.6 mm) Legs
PRESSED FAULT Provided for free standing installations when wall mounting is not
SPEED SWITCH FAILURE CONTACTOR COIL FAILURE practical. If specified, lifting eyes may also be supplied.
Plus any of the 8 programmable auxiliary alarms listed above
Enclosure
Every event or alarm that is recorded includes the following data The following NEMA type enclosures are also available: 3R, 4, 4X
with the recorded event or alarm: (Painted Cold Rolled Steel), 4X (304 or 316 Stainless Steel), and
• Time and Date of Event or Alarm 12.
• System Pressure
• Descriptive Text Message of the Event/Alarm
• System Auto Mode Status
• Engine Running Status
• Charger 1 Status
• Charger 2 Status
• Battery 1 Status
• Battery 2 Status
Fire Pump Controller
For Diesel Driven Fire Pumps
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: Controls,
Hubbell Industrial 336-434-2801 | Email:
Inc. ‑ Metron salesmail@metroninc.com
Fire Pump Control Division | 4301∙ Cheyenne
www.metroninc.com
Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com MSC0213 16
Bulletin FD4 01/11
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 18
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 19
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 20
ELECTRIC
FIRE PUMP
CONTROLLERS
SECTION CONTENTS:
Contents:
Electric Controller Option Details
Across the Line Start, Type MP300 Bulletin
Model MP300 Price Sheets
Electric
MP300 Controller
Drawings Option Details
High Voltage Across the Line Start, Type MP600 Bulletin
ModelModelMP300
MP600-Price
Across the Line Start
Sheets
MP600 Drawings
Primary
ModelResistance
MP600 Reduced
- High Voltage
VoltageStart, Type the
Across MP400 Bulletin
Line Start
Model MP400 Price Sheets
ModelModel MP400-Drawings
MP400 Primary Resistance Reduced Voltage Start
Part Winding Reduced Voltage, Type MP420 Bulletin
ModelModel MP420-Price
MP420 PartSheets
Winding Reduced Voltage
Model MP420 Drawings
Wye-Delta Reduced Current, Type
Model MP430/MP435 MP430 / MP435
- Wye-Delta Bulletin
Reduced Current
Model MP430 Price Sheets
ModelModel MP435-Price
MP450 Sheets
Autotransformer Closed Transisiton
Model MP430 Drawings
Reduced
Model Voltage
MP435 Drawings
Autotransformer Closed-Transition Reduced Voltage, Type MP450 Bulletin
ModelModelMP700
MP450-Price
Solid State Reduced Voltage
Sheets
Model MP450 Drawings
Model
Solid StateMP800
Reduced -Voltage,
Solid State Reduced
Type MP700 Voltage
Bulletin
Model MP700 Price Sheets
Model MP700 Drawings
Solid State Reduced Voltage, Type MP800 Bulletin
Model MP800 Price Sheets
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 22
TYPE ‘MP’ FULL SERVICE CONTROLLERS
The following features are standard on all Type ‘MP’ Full Service Electric Controllers:
If the ambient atmosphere is especially damp, a space heater rated at 100 watts may be supplied
to reduce moisture in the cabinet. A thermostat is supplied as standard with this option. A
humidistat may be substituted if specified.
For systems where the controller is mounted on a common skid with the pump and engine, the legs of the
controller may be omitted, and 3” mounting channels or wall mounting brackets can be supplied. If
specified lifting eyes may also be supplied.
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 23
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 25
All photographs and graphics are typical and may not represent actual product supplied
GAS DETECTION
HIGH VIBRATION Options
EMERGENCY POWER ON
PUMP ROOM DOOR OPEN Option H: Space Heater
If the ambient atmosphere is especially damp, a
Data logging: space heater rated at 100 watts may be supplied to
The controller includes two (2) separate data logs for reduce moisture in the cabinet. A thermostat is
storing system data that is readable through the OID supplied as standard with this option. A humidistat
or copied to a computer equipped with an SD card may be substituted if specified.
reader. The 2 data logs are as follows:
Option W: Omit Legs
Pressure Log: The pressure log provides a For systems where the controller is mounted on a
continuous pressure record for 30 days. The common skid with the pump and motor, the legs of
pressure log samples shall be time and date stamped the controller may be omitted, 3” (76.2mm) channels
and stored in permanent non-volatile SD memory or wall mounting brackets can be supplied. If
card. The pressure log can be searched by each specified, lifting eyes may also be supplied.
sample, by minute, or by hour through the OID.
Enclosure
Event Log: The event log will store up to 300 of the The following NEMA type enclosures are also
most current events. These events can include, but is available: 3R, 4, 4X (Painted Cold Rolled Steel), 4X
not limited to, any of the following events/alarms: (304 or 316 Stainless Steel), and 12
PUMP RUNNING
POWER AVAILABLE
PHASE REVERSAL
MOTOR OVERLOAD
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE
CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 26
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP300 Across‑the‑line Start Microprocessor Electric Motor Fire Pump Controller
event log, alarm log and all user changeable shall be searchable by each sample, by minute, or
Specifications set points and system data. Battery backup of
any kind not allowed.
by hour. Each day’s entries shall be stored in a
separate file on the SD card. SD memory shall be
Input and output status LED's to provide visual readable by any PC equipped with an SD
General Controller Description indication of each discrete input's or output's memory card reader.
The Fire Pump Controller shall be factory on/off status
Event Log: The event log shall be capable of
assembled, wired and tested as a unit and shall One RS485 Serial Port
storing no less than 3000 events. These events
conform to all requirements of the latest edition MODBUS Communication Protocol via shall include, but is not limited to, any of the
of NFPA 20, NFPA 70 and be Third Party Listed RS485 port following events/alarms:
by Underwriters Laboratories (UL) and All wiring terminals on PCB's shall be PUMP RUNNING
Approved by Factory Mutual (FM). The removable type POWER AVAILABLE
controller shall be available for 208, 230, 380- Service Entrance Rated PHASE REVERSAL
415, or 480 volt three phase power. MOTOR OVERLOAD
Auxiliary alarms
Controller Equipment Features REMOTE START
As standard the controller shall include 6 discrete LOCAL START
The controller shall include the following auxiliary inputs, 9 form 'C' auxiliary relay PUMP ON DEMAND
standard features: outputs. These auxiliary inputs and outputs are SYSTEM FAULT
NEMA Type 2 drip proof metal freestanding in addition to those mandated by NFPA 20. All PRESSURE TRANSDUCER FAULT
enclosure auxiliary inputs, outputs, and OID screens shall PUMP FAILED TO START
Operator Interface Device (OID) with 4 lines be field programmable through the OID. This LOW INTAKE SHUTDOWN ALARM
by 20 character display with large character permits a multitude of customizable controller SUPERVISORY POWER FAILURE
backlit LCD capable of being read in both configurations to meet each installations unique LOW PRESSURE
direct sunlight or dark lighting conditions needs without adding cost to the controller. The AUTO WEEKLY TEST START
10 pushbuttons for easy screen navigation, use of jumpers, soldering, or other external UNDER FREQUENCY
system test, lamp test, alarm reset, and horn components are not allowed. OVER FREQUENCY
silencing LOW ZONE / HIGH ZONE CONTACTS
The user can select any 9 of the following
Multicolored LED's for alarm and mode HIGH DISCHARGE PRESSURE
auxiliary alarms that can be programmed and
annunciation NO LOAD CONDITION
recorded in the event log and annunciated with
LEDs shall be labeled with removable labels an OID screen and output relay contact for Each event or alarm recorded in the event log
to allow for easy field modification of conditions such as but not limited to: shall have the following data recorded with the
language changes LOW PUMP ROOM TEMP event/alarm:
All controller settings shall be programmable RESERVOIR LOW Time and Date of Event or Alarm
through the OID and shall be protected by two RESERVOIR EMPTY System Pressure
password levels RESERVOIR HIGH Descriptive Text Message of the Event/Alarm
All features shall be enabled or disabled FLOW METER ON Motor Running Status
through the OID, no jumpers or external wires RELIEF VALVE OPEN Phase to Phase Volts
shall be needed or allowed to activate or de- LOW SUCTION PRESSURE
Phase Amps
activate a feature HIGH PUMP ROOM TEMPERATURE
The system status data shall be displayed on LOW FIREWATER PRESSURE The internal logic of the controller shall be
the OID. The displayed items shall include: LOW PURGE PRESSURE capable of operation in a temperature range of
System pressure, Phase to Phase (AB, BC, LOW GEAR OIL PRESSURE 4.4ºC to 40ºC and high, non-condensing,
AC) voltage, Phase current (A, B, C), System HIGH GEAR OIL TEMPERATURE humidity levels.
Events and Notifications, Current time and GAS DETECTION
date, Number of starts, Total motor run hours, HIGH VIBRATION The controller shall be manufactured by Metron.
Displayed countdown timers for: Sequential EMERGENCY POWER ON
motor start and motor stop, Status of PUMP ROOM DOOR OPEN
Automatic Stop Setting.
Data logging
Audible horn with silence feature for
silencable alarms The controller shall have separate data logs for
Lamp test feature storing system data that is readable through the
Foreign languages selectable through the OID OID.
Microprocessor based logic with real time/date
Pressure Log: The controller shall have a
clock capable of running a minimum of 14
Pressure log with continuous pressure recording
days without AC power connected to
of 30 days of data. The pressure log samples
controller and non-volatile flash memory to
shall be time and date stamped and stored on a
permanently store the continuous pressure log,
removable SD card memory. The pressure log
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP300 1/11 27
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 34
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 35
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 37
LOW SUCTION PRESSURE
HIGH PUMP ROOM TEMP. Options
LOW FIREWATER PRESSURE
LOW PURGE PRESSURE Option H: Space Heater
LOW GEAR OIL PRESSURE If the ambient atmosphere is especially damp, a space
HIGH GEAR OIL TEMP. heater rated at 100 watts may be supplied to reduce
GAS DETECTION moisture in the cabinet. A thermostat is supplied as
HIGH VIBRATION standard with this option. A humidistat may be
PUMP ROOM DOOR OPEN substituted if specified.
LOW INTAKE Option T: Weekly Test Start Solenoid
In some cases it may be desirable to have the electric
Data logging:
motor run at a preset time each week for approximately
The controller includes two (2) separate data logs for
30 minutes. The controller includes a built in weekly
storing system data that is readable through the OID or
test function. This option complements the standard
copied to a computer equipped with an SD card reader.
function by simulating a loss of pressure. Simulation of
The 2 data logs are as follows:
pressure loss is accomplished by opening a solenoid
Pressure Log: The pressure log provides a continuous valve, which reduces the system pressure below the
pressure record for 30 days. The pressure log samples starting pressure of the controller.
shall be time and date stamped and stored in
permanent non-volatile SD memory card. The Option W: Omit Legs
pressure log can be searched by each sample, by For systems where the controller is mounted on a
minute, or by hour through the OID. common skid with the pump and motor, the legs of the
controller may be omitted, 3” (76.2mm) channels may
Event Log: The event log will store up to 3000 of the be substituted in lieu of standard legs. If specified,
most current events. These events can include, but is lifting eyes may also be supplied.
not limited to, any of the following events/alarms:
PUMP RUNNING Enclosure
POWER AVAILABLE The following NEMA type enclosures are also
PHASE REVERSAL available: 3R, 4, 4X (Painted Cold Rolled Steel), 4X
MOTOR OVERLOAD (304 or 316 Stainless Steel), and 12
MOTOR TRIPPED
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
AUTO MODE
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
0212 v12
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP600 Across‑the‑line Start Microprocessor Electric Motor Fire Pump Controller
Lamp test feature Data logging
Specifications Foreign languages selectable through the OID
Microprocessor based logic with real
The controller shall have separate data logs for
storing system data that is readable through the
General Controller Description time/date clock capable of running a OID.
The fire pump controller shall be listed by minimum of 14 days without AC power
Underwriters Laboratories and approved by Pressure Log: The controller shall have a
connected to controller and non-volatile flash Pressure log with continuous pressure recording
Factory Mutual for fire pump service. The fire memory to permanently store the continuous
pump shall be completely factory wired, of 30 days of data. The pressure log samples
pressure log, event log, alarm log and all user shall be time and date stamped and stored on a
assembled, and tested prior to shipment. changeable set points and system data. removable SD card memory. The pressure log
The motor contactor shall be rated at least 400 Battery backup of any kind not allowed shall be searchable by each sample, by minute,
amps, 7200 VAC, be of the vacuum type, and Input and output status LED's to provide or by hour. Each days entries shall be stored in
shall be suitable for use on a circuit capable of visual indication of each discrete input's or a separate file on the SD card. SD memory shall
delivering not more than 50KA at 7200 VAC output's on/off status be readable by any PC equipped with an SD
short circuit current. The contactor shall be RS485 Communications Port memory card reader.
interlocked with the controller door to prohibit MODBUS Communication Protocol via
the door from being opened while the contactor RS485 port Event Log: The event log shall be capable of
is racked in. The main disconnect switch shall All wiring terminals on PCB's shall be storing no less than 3000 events. These events
contain integral fuse clips capable of holding removable type shall include, but is not limited to, any of the
“R” rated motor protection type fuses. Suitable following events/alarms:
Auxiliary alarms PUMP RUNNING
high voltage fuses shall be supplied and sized to
As standard the controller shall include 6 POWER AVAILABLE
hold motor locked rotor current as per NFPA 20.
discrete auxiliary inputs, 7 form 'C' auxiliary PHASE REVERSAL
Internal space shall be provided for spare fuse
relay outputs. These auxiliary inputs and MOTOR OVERLOAD
storage.
outputs are in addition to those mandated by MOTOR TRIPPED
Controller Equipment Features NFPA 20. All auxiliary inputs, outputs, and REMOTE START
The controller shall include the following OID screens shall be field programmable LOCAL START
standard features: through the OID. This permits a multitude of PUMP ON DEMAND
NEMA Type 2 drip proof metal freestanding customizable controller configurations to meet SYSTEM FAULT
enclosure each installations unique needs without adding AUTO MODE
Operator Interface Device (OID) with 4 lines cost to the controller. The use of jumpers, PRESSURE TRANSDUCER FAULT
by 20 character display with large character soldering, or other external components are not PUMP FAILED TO START
backlit LCD capable of being read in both allowed. LOW INTAKE SHUTDOWN ALARM
direct sunlight or dark lighting conditions The user can select any 7 of the following SUPERVISORY POWER FAILURE
10 pushbuttons for easy screen navigation, auxiliary alarms that can be programmed and LOW PRESSURE
system test, lamp test, alarm reset, and horn recorded in the event log and annunciated with AUTO WEEKLY TEST START
silencing an OID screen and output relay contact for UNDER FREQUENCY
LED's for alarm and status annunciation conditions such as, but not limited to: OVER FREQUENCY
LEDs shall be labeled with removable labels LOW PUMP ROOM TEMP LOW ZONE / HIGH ZONE CONTACTS
to allow for easy field modification of RESERVOIR LOW HIGH DISCHARGE PRESSURE
language changes RESERVOIR EMPTY NO LOAD CONDITION
All controller settings shall be programmable RESERVOIR HIGH Each event or alarm recorded in the event log
through the OID and shall be protected by FLOW METER ON shall have the following data recorded with the
two password levels RELIEF VALVE OPEN event/alarm:
All features shall be enabled or disabled LOW SUCTION PRESSURE Time and Date of Event or Alarm
through the OID, no jumpers or external wires HIGH PUMP ROOM TEMPERATURE System Pressure
shall be needed or allowed to activate or de- LOW FIREWATER PRESSURE Descriptive Text Message of the Event/Alarm
activate a feature LOW PURGE PRESSURE Motor Running Status
The system status data shall be displayed on LOW GEAR OIL PRESSURE
Phase to Phase Volts
the OID. The displayed items shall include: HIGH GEAR OIL TEMPERATURE
Phase Amps
System pressure, Phase to Phase (AB, BC, GAS DETECTION
AC) voltage, Phase current (A, B, C), System HIGH VIBRATION The internal logic of the controller shall be
Events and Notifications, Current time and PUMP ROOM DOOR OPEN capable of operation in a temperature range of
date, Number of starts, Total motor run hours, LOW INTAKE 4.4ºC to 40ºC and high, non-condensing,
Displayed countdown timers for: Sequential humidity levels.
motor start and motor stop
Audible horn with silence feature for The controller shall be manufactured by Metron.
silencable alarms
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP600 01/11 39
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 42
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 43
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 45
HIGH VIBRATION
EMERGENCY POWER ON Options
PUMP ROOM DOOR OPEN
Option H: Space Heater
Data logging: If the ambient atmosphere is especially damp, a space
The controller includes two (2) separate data logs for heater rated at 100 watts may be supplied to reduce
storing system data that is readable through the OID or moisture in the cabinet. A thermostat is supplied as
copied to a computer equipped with an SD card reader. standard with this option. A humidistat may be substituted
The 2 data logs are as follows: if specified.
Pressure Log: The pressure log provides a continuous Option W: Omit Legs
pressure record for 30 days. The pressure log samples For systems where the controller is mounted on a common
shall be time and date stamped and stored in permanent skid with the pump and motor, the legs of the controller
non-volatile SD memory card. The pressure log can be may be omitted, 3” (76.2mm) channels or wall mounting
searched by each sample, by minute, or by hour through brackets can be supplied. If specified, lifting eyes may also
the OID. be supplied.
Event Log: The event log will store up to 300 of the most Enclosure
current events. These events can include, but is not limited The following NEMA type enclosures are also available:
to, any of the following events/alarms: 3R, 4, 4X (Painted Cold Rolled Steel), 4X (304 or 316
PUMP RUNNING Stainless Steel), and 12
POWER AVAILABLE
PHASE REVERSAL
MOTOR OVERLOAD
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
0212 v12
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP400 Primary Resistance Start Microprocessor Electric Motor Fire Pump Controller
Microprocessor based logic with real time/date Data logging
Specifications clock capable of running a minimum of 14
days without AC power connected to
The controller shall have separate data logs for
storing system data that is readable through the
controller and non-volatile flash memory to
General Controller Description OID.
permanently store the continuous pressure log,
The Fire Pump Controller shall be factory event log, alarm log and all user changeable Pressure Log: The controller shall have a
assembled, wired and tested as a unit and shall set points and system data. Battery backup of Pressure log with continuous pressure recording
conform to all requirements of the latest edition any kind not allowed. of 30 days of data. The pressure log samples
of NFPA 20, NFPA 70 and be Third Party Listed Input and output status LED's to provide visual shall be time and date stamped and stored on a
by Underwriters Laboratories (UL) and indication of each discrete input's or output's removable SD card memory. The pressure log
Approved by Factory Mutual (FM). The on/off status shall be searchable by each sample, by minute, or
controller shall be available for 208, 230, 380- One RS485 Serial Port by hour. Each days entries shall be stored in a
415, or 480 volt three phase power. MODBUS Communication Protocol via separate file on the SD card. SD memory shall be
RS485 port readable by any PC equipped with an SD
Controller Equipment Features
All wiring terminals on PCB's shall be memory card reader.
The controller shall include the following removable type
Event Log: The event log shall be capable of
standard features: Service Entrance Rated storing no less than 3000 events. These events
NEMA Type 2 drip proof metal freestanding Auxiliary alarms shall include, but is not limited to, any of the
enclosure following events/alarms:
The controller shall be designed for Primary As standard the controller shall include 6 discrete PUMP RUNNING
Resistance starting. The controller shall start auxiliary inputs, 9 form 'C' auxiliary relay POWER AVAILABLE
outputs. These auxiliary inputs and outputs are PHASE REVERSAL
the motor in two steps, using heavy-duty
in addition to those mandated by NFPA 20. All MOTOR OVERLOAD
starting resistors to reduce the inrush current to
approximately 50% of normal. auxiliary inputs, outputs, and OID screens shall REMOTE START
be field programmable through the OID. This LOCAL START
Operator Interface Device (OID) with 4 lines
permits a multitude of customizable controller PUMP ON DEMAND
by 20 character display with large character
configurations to meet each installations unique SYSTEM FAULT
backlit LCD capable of being read in both
needs without adding cost to the controller. The PRESSURE TRANSDUCER FAULT
direct sunlight or dark lighting conditions
use of jumpers, soldering, or other external PUMP FAILED TO START
10 pushbuttons for easy screen navigation,
components are not allowed. LOW INTAKE SHUTDOWN ALARM
system test, lamp test, alarm reset, and horn
silencing The user can select any 9 of the following SUPERVISORY POWER FAILURE
Multicolored LED's for alarm and mode auxiliary alarms that can be programmed and LOW PRESSURE
annunciation recorded in the event log and annunciated with an AUTO WEEKLY TEST START
UNDER FREQUENCY
LEDs shall be labeled with removable labels to OID screen and output relay contact for
conditions such as but not limited to: OVER FREQUENCY
allow for easy field modification of language
LOW PUMP ROOM TEMP LOW ZONE / HIGH ZONE CONTACTS
changes
RESERVOIR LOW HIGH DISCHARGE PRESSURE
All controller settings shall be programmable
RESERVOIR EMPTY NO LOAD CONDITION
through the OID and shall be protected by two
password levels RESERVOIR HIGH Each event or alarm recorded in the event log
All features shall be enabled or disabled FLOW METER ON shall have the following data recorded with the
through the OID, no jumpers or external wires RELIEF VALVE OPEN event/alarm:
shall be needed or allowed to activate or de- LOW SUCTION PRESSURE Time and Date of Event or Alarm
activate a feature HIGH PUMP ROOM TEMPERATURE System Pressure
The system status data shall be displayed on LOW FIREWATER PRESSURE Descriptive Text Message of the Event/Alarm
the OID. The displayed items shall include: LOW PURGE PRESSURE Motor Running Status
System pressure, Phase to Phase (AB, BC, LOW GEAR OIL PRESSURE
Phase to Phase Volts
AC) voltage, Phase current (A, B, C), System HIGH GEAR OIL TEMPERATURE
Phase Amps
Events and Notifications, Current time and GAS DETECTION
date, Number of starts, Total motor run hours, HIGH VIBRATION The internal logic of the controller shall be
Displayed countdown timers for: Sequential EMERGENCY POWER ON capable of operation in a temperature range of
motor start and motor stop, Status of PUMP ROOM DOOR OPEN 4.4ºC to 40ºC and high, non-condensing,
Automatic Stop Setting. humidity levels.
Audible horn with silence feature for The controller shall be manufactured by Metron.
silencable alarms
Lamp test feature
Foreign languages selectable through the OID
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP400 01/11 47
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 52
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 53
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 55
HIGH GEAR OIL TEMPERATURE
GAS DETECTION Options
HIGH VIBRATION
EMERGENCY POWER ON Option H: Space Heater
PUMP ROOM DOOR OPEN If the ambient atmosphere is especially damp, a space
heater rated at 100 watts may be supplied to reduce
Data logging: moisture in the cabinet. A thermostat is supplied as
The controller includes two (2) separate data logs for standard with this option. A humidistat may be substituted
storing system data that is readable through the OID or if specified.
copied to a computer equipped with an SD card reader.
The 2 data logs are as follows: Option W: Omit Legs
For systems where the controller is mounted on a common
Pressure Log: The pressure log provides a continuous skid with the pump and motor, the legs of the controller
pressure record for 30 days. The pressure log samples may be omitted, 3” (76.2mm) channels or wall mounting
shall be time and date stamped and stored in permanent brackets can be supplied. If specified, lifting eyes may also
non-volatile SD memory card. The pressure log can be be supplied.
searched by each sample, by minute, or by hour through
the OID. Enclosure
The following NEMA type enclosures are also available:
Event Log: The event log will store up to 300 of the most 3R, 4, 4X (Painted Cold Rolled Steel), 4X (304 or 316
current events. These events can include, but is not Stainless Steel), and 12
limited to, any of the following events/alarms:
PUMP RUNNING
POWER AVAILABLE
PHASE REVERSAL
MOTOR OVERLOAD
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 56
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP420 Part Winding Start Microprocessor Electric Motor Fire Pump Controller
Audible horn with silence feature for Data logging
Specifications silencable alarms
Lamp test feature
The controller shall have separate data logs for
storing system data that is readable through the
Foreign languages selectable through the OID OID.
General Controller Description
The Fire Pump Controller shall be factory Microprocessor based logic with real time/date Pressure Log: The controller shall have a
assembled, wired and tested as a unit and shall clock capable of running a minimum of 14 Pressure log with continuous pressure recording
conform to all requirements of the latest edition days without AC power connected to of 30 days of data. The pressure log samples
of NFPA 20, NFPA 70 and be Third Party Listed controller and non-volatile flash memory to shall be time and date stamped and stored on a
by Underwriters Laboratories (UL) and permanently store the continuous pressure log, removable SD card memory. The pressure log
Approved by Factory Mutual (FM). The event log, alarm log and all user changeable shall be searchable by each sample, by minute, or
controller shall be available for 208, 230, 380- set points and system data. Battery backup of by hour. Each days entries shall be stored in a
415, or 480 volt three phase power. any kind not allowed. separate file on the SD card. SD memory shall be
Input and output status LED's to provide visual readable by any PC equipped with an SD
Controller Equipment Features indication of each discrete input's or output's memory card reader.
The controller shall include the following on/off status
standard features: One RS485 Serial Port Event Log: The event log shall be capable of
MODBUS Communication Protocol via storing no less than 3000 events. These events
NEMA Type 2 drip proof metal freestanding shall include, but is not limited to, any of the
enclosure RS485 port
All wiring terminals on PCB's shall be following events/alarms:
The Controller shall be designed for Part removable type PUMP RUNNING
Winding starting. The starting contactors shall Service Entrance Rated POWER AVAILABLE
operate in sequence to energize a portion of PHASE REVERSAL
the motor windings on start which reduces Auxiliary alarms MOTOR OVERLOAD
inrush current to approximately 65% of As standard the controller shall include 6 discrete REMOTE START
normal. An adjustable timing relay shall be auxiliary inputs, 9 form 'C' auxiliary relay LOCAL START
provided to control time between reduced outputs. These auxiliary inputs and outputs are PUMP ON DEMAND
current start and normal running operation. in addition to those mandated by NFPA 20. All SYSTEM FAULT
auxiliary inputs, outputs, and OID screens shall PRESSURE TRANSDUCER FAULT
Operator Interface Device (OID) with 4 lines be field programmable through the OID. This PUMP FAILED TO START
by 20 character display with large character permits a multitude of customizable controller LOW INTAKE SHUTDOWN ALARM
backlit LCD capable of being read in both configurations to meet each installations unique SUPERVISORY POWER FAILURE
direct sunlight or dark lighting conditions needs without adding cost to the controller. The LOW PRESSURE
10 pushbuttons for easy screen navigation, use of jumpers, soldering, or other external AUTO WEEKLY TEST START
system test, lamp test, alarm reset, and horn components are not allowed. UNDER FREQUENCY
silencing OVER FREQUENCY
The user can select any 9 of the following
Multicolored LED's for alarm and mode LOW ZONE / HIGH ZONE CONTACTS
annunciation auxiliary alarms that can be programmed and
HIGH DISCHARGE PRESSURE
recorded in the event log and annunciated with
LEDs shall be labeled with removable labels NO LOAD CONDITION
an OID screen and output relay contact for
to allow for easy field modification of
conditions such as but not limited to: Each event or alarm recorded in the event log
language changes
LOW PUMP ROOM TEMP shall have the following data recorded with the
All controller settings shall be programmable
RESERVOIR LOW event/alarm:
through the OID and shall be protected by two
RESERVOIR EMPTY Time and Date of Event or Alarm
password levels
RESERVOIR HIGH System Pressure
All features shall be enabled or disabled FLOW METER ON
through the OID, no jumpers or external wires Descriptive Text Message of the Event/Alarm
RELIEF VALVE OPEN Motor Running Status
shall be needed or allowed to activate or de- LOW SUCTION PRESSURE
activate a feature Phase to Phase Volts
HIGH PUMP ROOM TEMPERATURE Phase Amps
The system status data shall be displayed on LOW FIREWATER PRESSURE
the OID. The displayed items shall include: LOW PURGE PRESSURE The internal logic of the controller shall be
System pressure, Phase to Phase (AB, BC, LOW GEAR OIL PRESSURE capable of operation in a temperature range of
AC) voltage, Phase current (A, B, C), System HIGH GEAR OIL TEMPERATURE 4.4ºC to 40ºC and high, non-condensing,
Events and Notifications, Current time and GAS DETECTION humidity levels.
date, Number of starts, Total motor run hours, HIGH VIBRATION
Displayed countdown timers for: Sequential The controller shall be manufactured by Metron.
EMERGENCY POWER ON
motor start and motor stop, Status of PUMP ROOM DOOR OPEN
Automatic Stop Setting.
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800
Phone: 336-434-2800 ∙ Fax:
∙ Fax: 336-434-2801 || Email:
336-434-2801 Email:salesmail@metroninc.com
salesmail@metroninc.com∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP420 01/11
MSC0213 57
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 64
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 65
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Wye−Delta Reduced
Current Types
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
All photographs and graphics are typical and may not represent actual product supplied
0212 v12
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP430/435 Wye‑Delta Start Microprocessor Electric Motor Fire Pump Controller
Microprocessor based logic with real time/date Data logging
Specifications clock capable of running a minimum of 14
days without AC power connected to
The controller shall have separate data logs for
storing system data that is readable through the
General Controller Description controller and non-volatile flash memory to OID.
permanently store the continuous pressure log,
The Fire Pump Controller shall be factory Pressure Log: The controller shall have a
event log, alarm log and all user changeable
assembled, wired and tested as a unit and shall Pressure log with continuous pressure recording
set points and system data. Battery backup of
conform to all requirements of the latest edition of 30 days of data. The pressure log samples
any kind not allowed.
of NFPA 20, NFPA 70 and be Third Party Listed shall be time and date stamped and stored on a
by Underwriters Laboratories (UL) and Input and output status LED's to provide visual
removable SD card memory. The pressure log
Approved by Factory Mutual (FM). The indication of each discrete input's or output's
shall be searchable by each sample, by minute, or
controller shall be available for 208, 230, 380- on/off status
by hour. Each days entries shall be stored in a
415, or 480 volt three phase power. One RS485 Serial Port separate file on the SD card. SD memory shall be
MODBUS Communication Protocol via readable by any PC equipped with an SD
Controller Equipment Features RS485 port memory card reader.
The controller shall include the following All wiring terminals on PCB's shall be
removable type Event Log: The event log shall be capable of
standard features:
Service Entrance Rated storing no less than 3000 events. These events
NEMA Type 2 drip proof metal freestanding shall include, but is not limited to, any of the
enclosure Auxiliary alarms following events/alarms:
The controller shall be designed for Wye-Delta As standard the controller shall include 6 discrete PUMP RUNNING
starting and shall start the motor in the Wye auxiliary inputs, 9 form 'C' auxiliary relay POWER AVAILABLE
configuration drawing 33% of normal current, outputs. These auxiliary inputs and outputs are PHASE REVERSAL
then connect the motor in the Delta in addition to those mandated by NFPA 20. All MOTOR OVERLOAD
configuration applying full voltage. auxiliary inputs, outputs, and OID screens shall REMOTE START
Operator Interface Device (OID) with 4 lines be field programmable through the OID. This LOCAL START
by 20 character display with large character permits a multitude of customizable controller PUMP ON DEMAND
backlit LCD capable of being read in both configurations to meet each installations unique SYSTEM FAULT
direct sunlight or dark lighting conditions needs without adding cost to the controller. The PRESSURE TRANSDUCER FAULT
10 pushbuttons for easy screen navigation, use of jumpers, soldering, or other external PUMP FAILED TO START
system test, lamp test, alarm reset, and horn components are not allowed. LOW INTAKE SHUTDOWN ALARM
silencing SUPERVISORY POWER FAILURE
The user can select any 9 of the following LOW PRESSURE
Multicolored LED's for alarm and mode
auxiliary alarms that can be programmed and AUTO WEEKLY TEST START
annunciation
recorded in the event log and annunciated with UNDER FREQUENCY
LEDs shall be labeled with removable labels
an OID screen and output relay contact for OVER FREQUENCY
to allow for easy field modification of
conditions such as but not limited to: LOW ZONE / HIGH ZONE CONTACTS
language changes
LOW PUMP ROOM TEMP HIGH DISCHARGE PRESSURE
All controller settings shall be programmable
RESERVOIR LOW NO LOAD CONDITION
through the OID and shall be protected by two RESERVOIR EMPTY
password levels RESERVOIR HIGH Each event or alarm recorded in the event log
All features shall be enabled or disabled FLOW METER ON shall have the following data recorded with the
through the OID, no jumpers or external wires RELIEF VALVE OPEN event/alarm:
shall be needed or allowed to activate or de- LOW SUCTION PRESSURE Time and Date of Event or Alarm
activate a feature HIGH PUMP ROOM TEMPERATURE System Pressure
The system status data shall be displayed on LOW FIREWATER PRESSURE Descriptive Text Message of the Event/Alarm
the OID. The displayed items shall include: LOW PURGE PRESSURE Motor Running Status
System pressure, Phase to Phase (AB, BC, LOW GEAR OIL PRESSURE Phase to Phase Volts
AC) voltage, Phase current (A, B, C), System HIGH GEAR OIL TEMPERATURE Phase Amps
Events and Notifications, Current time and GAS DETECTION
date, Number of starts, Total motor run hours, The internal logic of the controller shall be
HIGH VIBRATION
Displayed countdown timers for: Sequential capable of operation in a temperature range of
EMERGENCY POWER ON
motor start and motor stop, Status of 4.4ºC to 40ºC and high, non-condensing,
PUMP ROOM DOOR OPEN
Automatic Stop Setting. humidity levels.
Audible horn with silence feature for The controller shall be manufactured by Metron.
silencable alarms
Lamp test feature
Foreign languages selectable through the OID
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP430/MP435 01/11 69
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 77
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 78
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 85
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 86
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Autotransformer
Closed−Transition
Reduced Voltage Type
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 88
All photographs and graphics are typical and may not represent actual product supplied
FLOW METER ON
RELIEF VALVE OPEN Options
LOW SUCTION PRESSURE
HIGH PUMP ROOM TEMPERATURE Option H: Space Heater
LOW FIREWATER PRESSURE If the ambient atmosphere is especially damp, a space
LOW PURGE PRESSURE heater rated at 100 watts may be supplied to reduce
LOW GEAR OIL PRESSURE moisture in the cabinet. A thermostat is supplied as
HIGH GEAR OIL TEMPERATURE standard with this option. A humidistat may be substituted
GAS DETECTION if specified.
HIGH VIBRATION Option W: Omit Legs
EMERGENCY POWER ON For systems where the controller is mounted on a common
PUMP ROOM DOOR OPEN skid with the pump and motor, the legs of the controller
Data logging: may be omitted, 3” (76.2mm) channels or wall mounting
The controller includes two (2) separate data logs for brackets can be supplied. If specified, lifting eyes may also
storing system data that is readable through the OID or be supplied.
copied to a computer equipped with an SD card reader. Enclosure
The 2 data logs are as follows: The following NEMA type enclosures are also available:
Pressure Log: The pressure log provides a continuous 3R, 4, 4X (Painted Cold Rolled Steel), 4X (304 or 316
pressure record for 30 days. The pressure log samples Stainless Steel), and 12
shall be time and date stamped and stored in permanent
non-volatile SD memory card. The pressure log can be
searched by each sample, by minute, or by hour through
the OID.
Event Log: The event log will store up to 300 of the most
current events. These events can include, but is not limited
to, any of the following events/alarms:
PUMP RUNNING
POWER AVAILABLE
PHASE REVERSAL
MOTOR OVERLOAD
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
MSC0212 v11
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP450 Autotransformer Start Microprocessor Electric Motor Fire Pump Controller
Microprocessor based logic with real time/date Data logging
Specifications clock capable of running a minimum of 14
days without AC power connected to
The controller shall have separate data logs for
storing system data that is readable through the
General Controller Description controller and non-volatile flash memory to OID.
The Fire Pump Controller shall be factory permanently store the continuous pressure log,
Pressure Log: The controller shall have a
assembled, wired and tested as a unit and shall event log, alarm log and all user changeable
Pressure log with continuous pressure recording
conform to all requirements of the latest edition set points and system data. Battery backup of
of 30 days of data. The pressure log samples
of NFPA 20, NFPA 70 and be Third Party Listed any kind not allowed.
shall be time and date stamped and stored on a
by Underwriters Laboratories (UL) and Input and output status LED's to provide visual
removable SD card memory. The pressure log
Approved by Factory Mutual (FM). The indication of each discrete input's or output's
shall be searchable by each sample, by minute, or
controller shall be available for 208, 230, 380- on/off status
by hour. Each days entries shall be stored in a
415, or 480 volt three phase power. RS485 Communications Port separate file on the SD card. SD memory shall be
Controller Equipment Features MODBUS Communication Protocol via readable by any PC equipped with an SD
RS485 port memory card reader.
The controller shall include the following
All wiring terminals on PCB's shall be
standard features: Event Log: The event log shall be capable of
removable type
storing no less than 3000 events. These events
NEMA Type 2 drip proof metal freestanding Service Entrance Rated
shall include, but is not limited to, any of the
enclosure Auxiliary alarms following events/alarms:
The controller shall be designed for PUMP RUNNING
As standard the controller shall include 6 discrete
Autotransformer starting and shall start the POWER AVAILABLE
auxiliary inputs, 9 form 'C' auxiliary relay
motor using a heavy-duty motor starting outputs. These auxiliary inputs and outputs are PHASE REVERSAL
autotransformer, reducing inrush current to in addition to those mandated by NFPA 20. All MOTOR OVERLOAD
42% of normal using the 65% tap. Taps of REMOTE START
auxiliary inputs, outputs, and OID screens shall
25% and 80% shall be supplied. LOCAL START
be field programmable through the OID. This
Operator Interface Device (OID) with 4 lines permits a multitude of customizable controller PUMP ON DEMAND
by 20 character display with large character configurations to meet each installations unique SYSTEM FAULT
backlit LCD capable of being read in both needs without adding cost to the controller. The PRESSURE TRANSDUCER FAULT
direct sunlight or dark lighting conditions use of jumpers, soldering, or other external PUMP FAILED TO START
10 pushbuttons for easy screen navigation, components are not allowed. LOW INTAKE SHUTDOWN ALARM
system test, lamp test, alarm reset, and horn SUPERVISORY POWER FAILURE
silencing The user can select any 9 of the following
auxiliary alarms that can be programmed and LOW PRESSURE
Multicolored LED's for alarm and mode AUTO WEEKLY TEST START
recorded in the event log and annunciated with
annunciation UNDER FREQUENCY
an OID screen and output relay contact for
LEDs shall be labeled with removable labels OVER FREQUENCY
conditions such as but not limited to:
to allow for easy field modification of LOW ZONE / HIGH ZONE CONTACTS
LOW PUMP ROOM TEMP
language changes HIGH DISCHARGE PRESSURE
RESERVOIR LOW
All controller settings shall be programmable NO LOAD CONDITION
RESERVOIR EMPTY
through the OID and shall be protected by two RESERVOIR HIGH Each event or alarm recorded in the event log
password levels FLOW METER ON shall have the following data recorded with the
All features shall be enabled or disabled RELIEF VALVE OPEN event/alarm:
through the OID, no jumpers or external wires LOW SUCTION PRESSURE Time and Date of Event or Alarm
shall be needed or allowed to activate or de- HIGH PUMP ROOM TEMPERATURE System Pressure
activate a feature LOW FIREWATER PRESSURE Descriptive Text Message of the Event/Alarm
The system status data shall be displayed on LOW PURGE PRESSURE Motor Running Status
the OID. The displayed items shall include: LOW GEAR OIL PRESSURE Phase to Phase Volts
System pressure, Phase to Phase (AB, BC, HIGH GEAR OIL TEMPERATURE
AC) voltage, Phase current (A, B, C), Phase Amps
GAS DETECTION
System Events and Notifications, Current The internal logic of the controller shall be
HIGH VIBRATION
time and date, Number of starts, Total motor capable of operation in a temperature range of
EMERGENCY POWER ON
run hours, Displayed countdown timers for: 4.4ºC to 40ºC and high, non-condensing,
PUMP ROOM DOOR OPEN
Sequential motor start and motor stop, humidity levels.
Status of Automatic Stop Setting. The controller shall be manufactured by Metron.
Audible horn with silence feature for
silencable alarms
Lamp test feature
Foreign languages selectable through the OID
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP450 01-11 90
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 96
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 97
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Solid State
Reduced Voltage Types
Series MP700
Soft Start, Soft Stop
Metron Fire Pump Controllers conform to the
latest requirements of Chapter 10, National Fire
Protection Association Pamphlet 20, Standard
for Centrifugal Fire Pumps as adopted by
Underwriters Laboratories and Factory Mutual.
MSC0212 v11
Standard and Optional Features
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 100
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP700 Soft Start/Soft Stop Microprocessor Electric Motor Fire Pump Controller
Audible horn with silence feature for Data logging
Specifications silencable alarms
Lamp test feature
The controller shall have separate data logs for
storing system data that is readable through the
Foreign languages selectable through the OID OID.
The Fire Pump Controller shall be factory
assembled, wired and tested as a unit and shall Microprocessor based logic with real Pressure Log: The controller shall have a
conform to all requirements of the latest edition time/date clock capable of running a Pressure log with continuous pressure recording
of NFPA 20, NFPA 70 and be Third Party minimum of 14 days without AC power of 30 days of data. The pressure log samples
Listed by Underwriters Laboratories (UL) and connected to controller and non-volatile flash shall be time and date stamped and stored on a
Approved by Factory Mutual (FM). The memory to permanently store the continuous removable SD card memory. The pressure log
controller shall be available for 208, 230, 380- pressure log, event log, alarm log and all user shall be searchable by each sample, by minute,
415, or 480 volt three phase power. changeable set points and system data. or by hour. Each days entries shall be stored in a
Battery backup of any kind not allowed separate file on the SD card. SD memory shall
Controller Equipment Features Input and output status LED's to provide be readable by any PC equipped with an SD
The controller shall include the following visual indication of each discrete input's or memory card reader.
standard features: output's on/off status
RS485 Communications Port Event Log: The event log shall be capable of
NEMA Type 2 drip proof metal freestanding MODBUS Communication Protocol via storing no less than 3000 events. These events
enclosure RS485 port shall include, but is not limited to, any of the
The controller shall be designed for Soft Start All wiring terminals on PCB's shall be following events/alarms:
starting and shall incorporate a special Pump removable type PUMP RUNNING
Control feature which eliminates excessive POWER AVAILABLE
Service Entrance Rated
acceleration torque problems (water hammer) PHASE REVERSAL
and related effects. The controller shall stop Auxiliary alarms MOTOR OVERLOAD
the motor by reducing the speed in a manner As standard the controller shall include 6 REMOTE START
that prevents any sudden changes in torque discrete auxiliary inputs, 9 form 'C' auxiliary LOCAL START
and minimizes surges in the system resulting relay outputs. These auxiliary inputs and PUMP ON DEMAND
in a smooth deceleration to the pump outputs are in addition to those mandated by SYSTEM FAULT
Operator Interface Device (OID) with 4 lines NFPA 20. All auxiliary inputs, outputs, and PRESSURE TRANSDUCER FAULT
by 20 character display with large character OID screens shall be field programmable PUMP FAILED TO START
backlit LCD capable of being read in both through the OID. This permits a multitude of LOW INTAKE SHUTDOWN ALARM
direct sunlight or dark lighting conditions customizable controller configurations to meet SUPERVISORY POWER FAILURE
10 pushbuttons for easy screen navigation, each installations unique needs without adding LOW PRESSURE
system test, lamp test, alarm reset, and horn cost to the controller. The use of jumpers, AUTO WEEKLY TEST START
silencing soldering, or other external components are not UNDER FREQUENCY
Multicolored LED's for alarm and mode allowed. OVER FREQUENCY
annunciation LOW ZONE / HIGH ZONE CONTACTS
The user can select any 9 of the following
LEDs shall be labeled with removable labels HIGH DISCHARGE PRESSURE
auxiliary alarms that can be programmed and
to allow for easy field modification of NO LOAD CONDITION
recorded in the event log and annunciated with
language changes an OID screen and output relay contact for Each event or alarm recorded in the event log
All controller settings shall be programmable conditions such as but not limited to: shall have the following data recorded with the
through the OID and shall be protected by LOW PUMP ROOM TEMP event/alarm:
two password levels RESERVOIR LOW Time and Date of Event or Alarm
All features shall be enabled or disabled RESERVOIR EMPTY System Pressure
through the OID, no jumpers or external wires RESERVOIR HIGH Descriptive Text Message of the Event/Alarm
shall be needed or allowed to activate or de- FLOW METER ON Motor Running Status
activate a feature RELIEF VALVE OPEN Phase to Phase Volts
The system status data shall be displayed LOW SUCTION PRESSURE
on the OID. The displayed items shall Phase Amps
HIGH PUMP ROOM TEMPERATURE
include: System pressure, Phase to Phase LOW FIREWATER PRESSURE The internal logic of the controller shall be
(AB, BC, AC) voltage, Phase current (A, LOW PURGE PRESSURE capable of operation in a temperature range of
B, C), System Events and Notifications, LOW GEAR OIL PRESSURE 4.4ºC to 40ºC and high, non-condensing,
Current time and date, Number of starts, HIGH GEAR OIL TEMPERATURE humidity levels.
Total motor run hours, Displayed GAS DETECTION
countdown timers for: Sequential motor The controller shall be manufactured by Metron.
HIGH VIBRATION
start and motor stop, Status of Automatic EMERGENCY POWER ON
Stop Setting PUMP ROOM DOOR OPEN
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin MP700 01/11101
MSC0213
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 106
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 107
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Series MP800
Variable Frequency Drive (VFD)
Metron Fire Pump Controllers conform to the latest
requirements of Chapter 10, National Fire
Protection Association Pamphlet 20, Standard for
Centrifugal Fire Pumps as adopted by
Underwriters Laboratories and Factory Mutual.
Function - The MP800 series Variable Frequency Drive Current time and date, System Events and Notifications
(VFD) electric motor fire pump controllers utilizes a state such as Remote Start, Local Start etc., Number of
of the art VFD with Swinging Choke Filter that is suitable starts, Total motor run hours, Time remaining on
for operation of a motor rated for VFD operation. The sequential motor start and motor stop timers, Status of
controller is designed for operation of motors that operate automatic stop setting.
with a 1.0 service factor. The controller compensates for • Auxiliary alarm functions displayed on the OID LCD
the effects of changing suction pressures that result in a screen
higher pump discharge pressure. The VFD provides soft • Audible horn with silence feature for silenceable alarms
start (ramp up) and soft stop (ramp down) to minimize • Lamp test feature
water hammer. Due to the operation characteristics of • Foreign languages selectable through the OID
the VFD the inrush current is greatly reduced. The • Microprocessor based logic with real time/date clock
current limit is factory default at 125% of full load current capable of running a minimum of 14 days without AC
but is field adjustable. power connected to controller
• SD Memory card used to record pressure log, event
Standard Features and log, and auxiliary user programs. Pressure log is
Operator Interface Device (OID) with LED Annunciator stored in separate comma delimited ASCII text files with
and Digital Display each file containing data for one day. The SD card is
removable and can be read by any PC equipped with
an SD card reader.
• Input and output status LED's provide visual indication
of each discrete input's or output's on/off status
• One RS485 Serial Port
• MODBUS Communication Protocol via RS485 port
• Service Entrance Rated
Auxiliary alarms:
The controller includes as standard five (5) discrete
auxiliary inputs, seven (7) form 'C' auxiliary relay outputs.
These auxiliary inputs and outputs are in addition to those
mandated by NFPA 20. All auxiliary inputs, outputs, and
OID Display can be field programmed through the OID.
Five (5) of the following auxiliary alarms can be
programmed and recorded in the event/alarm logs and
annunciated on the OID display screen and/or output
relay contact(s). These alarm conditions include:
• NEMA Type 2 drip proof metal freestanding enclosure LOW PUMP ROOM TEMP
• Operator Interface Device (OID) with 4 lines by 20 RESERVOIR LOW
character display with large character backlit Liquid RESERVOIR EMPTY
Crystal Display (LCD) capable of being read in both RESERVOIR HIGH
direct sunlight or dark lighting conditions FLOW METER ON
• 10 pushbuttons for easy screen navigation, LED lamp RELIEF VALVE OPEN
test, alarm reset, controller test and horn silencing LOW SUCTION PRESSURE
• Removable labels to allow for easy field language HIGH PUMP ROOM TEMPERATURE
changes LOW FIREWATER PRESSURE
• All controller settings are programmable through the LOW PURGE PRESSURE
OID. All features are enabled or disabled through the LOW GEAR OIL PRESSURE
OID, no jumpers or external wires are needed allowing HIGH GEAR OIL TEMPERATURE
easy field modification GAS DETECTION
• The system status data is displayed on the OID. The HIGH VIBRATION
displayed items include: System pressure, Phase to EMERGENCY POWER ON
Phase (AB, BC, AC) voltage, Phase current (A, B, C), PUMP ROOM DOOR OPEN
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied MSC0213 109
Data logging:
The controller includes two (2) separate data logs for Options
storing system data that is readable through the OID or
copied to a computer equipped with an SD card reader. Option H: Space Heater
The 2 data logs are as follows: If the ambient atmosphere is especially damp, a space
heater rated at 100 watts may be supplied to reduce
Pressure Log: The pressure log provides a continuous moisture in the cabinet. A thermostat is supplied as
pressure record for up to 31 days. The pressure log standard with this option. A humidistat may be
samples are time and date stamped and stored in substituted if specified.
permanent non-volatile SD memory card. The pressure
log can be searched by each sample, by minute, or by Option W: Omit Legs
hour through the OID. For systems where the controller is mounted on a
common skid with the pump and motor, the legs of the
Event Log: The event log will store up to 3000 of the controller may be omitted, 3” (76.2mm) channels or wall
most current events. These events can include, but is not mounting brackets can be supplied. If specified, lifting
limited to, any of the following events/alarms: eyes may also be supplied.
PUMP RUNNING
POWER AVAILABLE Additional Options
PHASE REVERSAL Reduced voltage bypass starting: Autotransformer Start
MOTOR OVERLOAD or Solid State Soft Start/Stop.
REMOTE START Enclosure
LOCAL START The following NEMA 12 standard.
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 110
Fire Pump Controller
For Electric Motor Driven Fire Pumps
Model MP800 Variable Frequency Drive (VFD) Electric Motor Fire Pump Controller
Audible horn with silence feature for Data logging
Specifications silenceable alarms
Lamp test feature
The controller shall have separate data logs for
storing system data that is readable through the
The Fire Pump Controller shall be factory Foreign languages selectable through the OID OID.
assembled, wired and tested as a unit and shall Microprocessor based logic with real time/date
conform to all requirements of the latest edition of clock capable of running a minimum of 14 days Pressure Log: The controller shall have a pressure
NFPA 20, NFPA 70 and be Third Party Listed by without AC power connected to controller and log with continuous pressure recording for up to
Underwriters Laboratories (UL). The controller non-volatile flash memory to permanently store 31 days of data. The pressure log samples shall be
shall be available for 208, 230, 380-415, or 480 the continuous pressure log, event log, alarm time and date stamped and stored on a removable
volt three phase power. log and all user changeable set points and SD card memory. The pressure log shall be
system data. Battery backup of any kind not searchable by each sample, by minute, or by hour.
Controller Equipment Features
allowed. Each days entries shall be stored in a separate file
The controller shall include the following standard Input and output status LED's to provide visual on the SD card. SD memory shall be readable by
features: indication of each discrete input's or output's any PC equipped with an SD memory card reader.
NEMA Type 12 drip proof metal freestanding on/off status
Event Log: The event log shall be capable of
enclosure One RS485 Serial Port
storing no less than 3000 events. These events
Variable Frequency Drive (VFD) electric motor MODBUS Communication Protocol via RS485 shall include, but is not limited to, any of the
fire pump controllers utilizes a state of the art port following events/alarms:
VFD with Swinging Choke Filter that is suitable All wiring terminals on PCB's shall be PUMP RUNNING
for operation of a motor rated for VFD removable type POWER AVAILABLE
operation. The controller is designed for Service Entrance Rated PHASE REVERSAL
operation of motors that operate with a 1.0 Auxiliary alarms MOTOR OVERLOAD
service factor only. The controller compensates REMOTE START
for the effects of changing suction pressures that As standard the controller shall include 5 discrete LOCAL START
result in a higher pump discharge pressure. The auxiliary inputs, 7 form 'C' auxiliary relay outputs. PUMP ON DEMAND
VFD provides soft start (ramp up) and soft stop These auxiliary inputs and outputs are in addition SYSTEM FAULT
(ramp down) to minimize water hammer. Due to those mandated by NFPA 20. All auxiliary PRESSURE TRANSDUCER FAULT
to the operation characteristics of the VFD the inputs, outputs, and OID screens shall be field PUMP FAILED TO START
inrush current is greatly reduced. The current programmable through the OID. This permits a LOW INTAKE SHUTDOWN ALARM
limit is factory default at 125% of full load multitude of customizable controller SUPERVISORY POWER FAILURE
current but is field adjustable. configurations to meet each installations unique LOW PRESSURE
Operator Interface Device (OID) with 4 lines by needs without adding cost to the controller. The AUTO WEEKLY TEST START
20 character display with large character backlit use of jumpers, soldering, or other external UNDER FREQUENCY
LCD capable of being read in both direct components are not allowed. OVER FREQUENCY
sunlight or dark lighting conditions LOW ZONE / HIGH ZONE CONTACTS
The user can select any 5 of the following
10 pushbuttons for easy screen navigation, HIGH DISCHARGE PRESSURE
auxiliary alarms that can be programmed and
system test, lamp test, alarm reset, and horn NO LOAD CONDITION
recorded in the event log and annunciated with an
silencing
OID screen and output relay contact for conditions Each event or alarm recorded in the event log shall
Multicolored LED's for alarm and mode such as but not limited to: have the following data recorded with the
annunciation
LOW PUMP ROOM TEMP event/alarm:
LEDs shall be labeled with removable labels to RESERVOIR LOW Time and Date of Event or Alarm
allow for easy field modification of language RESERVOIR EMPTY System Pressure
changes RESERVOIR HIGH Descriptive Text Message of the Event/Alarm
All controller settings shall be programmable FLOW METER ON
through the OID and shall be protected by two Motor Running Status
RELIEF VALVE OPEN Phase to Phase Volts
password levels LOW SUCTION PRESSURE
All features shall be enabled or disabled through Phase Amps
HIGH PUMP ROOM TEMPERATURE
the OID, no jumpers or external wires shall be LOW FIREWATER PRESSURE The internal logic of the controller shall be capable
needed or allowed to activate or de-activate a LOW PURGE PRESSURE of operation in a temperature range of 4.4ºC to
feature LOW GEAR OIL PRESSURE 40ºC and high, non-condensing, humidity levels.
The system status data shall be displayed on the HIGH GEAR OIL TEMPERATURE
OID. The displayed items shall include: System GAS DETECTION The controller shall be manufactured by Metron.
pressure, Phase to Phase (AB, BC, AC) voltage, HIGH VIBRATION
Phase current (A, B, C), System Events and EMERGENCY POWER ON
Notifications, Current time and date, Number of PUMP ROOM DOOR OPEN
starts, Total motor run hours, Displayed
countdown timers for: Sequential motor start
and motor stop, Status of Automatic Stop
Setting.
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com Bulletin MP800 01/11
MSC0213 111
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 118
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 119
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 120
TRANSFER
Contents:
SWITCHES
SECTION CONTENTS:
Full Service Power Transfer Switch Bulletin
FullTransfer
Service Power
Switch Transfer Switches
Schematic
Model MP300 with Transfer Switch Price Sheet
Model MP300 with Transfer Switch Drawings
Model MP300 - Across the Line Start
Model MP400 with Transfer Switch Price Sheet Switch
Model MP400 with Transfer Switch Drawings
Model MP600 - High Voltage Across the Line Start
Model MP420 with Transfer Switch Price Sheet
Model MP420 with Transfer Switch Drawings
Model MP400
Model MP430 with- Transfer
PrimarySwitch
Resistance Reduced Voltage Start
Price Sheet
Model MP430 with Transfer Switch Drawings
Model MP420
Model MP435 with- Transfer
Part Winding Reduced
Switch Price Sheet Voltage
Model MP435 with Transfer Switch Drawings
Model MP430/MP435
Model MP450 with Transfer -Switch
Wye-Delta Reduced Current
Price Sheet
Model MP450 with Transfer Switch Drawings
Model MP450
Model MP700 with- Transfer
Autotransformer
Switch Price Closed
Sheet Transisiton Reduced Voltage
Model MP700 with Transfer Switch Drawings
Model MP700
Model MP800 with- Transfer
Solid State
SwitchReduced
Price SheetVoltage
Limited Service Model M30 with Transfer Switch Bulletin
Model MP800
Model M30 - SolidSwitch
with Transfer StatePrice
Reduced
Sheets Voltage
Model M30 with Transfer Switch Drawings
Limited Service with Transfer Switch
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 121
Power Transfer Switches
For Electric Motor Driven Fire Pumps
Series MTS
Automatic Transfer Switch
Metron MTS Automatic Transfer Switch provide operation of electric fire
pump motors from a alternate source of power when the normal source
fails. They may be used with any Metron electric fire pump controller—
Across the Line, Primary Resistance, Part Winding, Wye-Delta, Auto
Transformer or Solid State Reduced Voltage Types. These transfer
switches are an integral part of the fire pump controller. They are factory
assembled, shipped and installed as a part of the controller.
The combination fire pump controller/transfer switch is listed by
Underwriters’ Laboratories’, Factory Mutual, and meets all the latest
requirements of Chapter 10 of NFPA 20 Standard for Installation of
Centrifugal Fire Pumps.
The MTS Automatic Transfer Switch is a mechanically held double throw
switch with a fast acting drive mechanism. Operating coils are
momentarily energized from the source to which the load is being
transferred. The switch is interlocked electrically and mechanically to
prevent both services form feeding the load at the same time. The
transfer switch is capable of manual (non-electrical) operation.
Under voltage sensing devices are supplied which monitor each phase of
normal service. When the voltage of any phase falls below the pre-set
level the transfer switch automatically transfers to the alternate source.
Voltage and frequency sensing devices are provided to monitor one
phase of the alternate source and will inhibit transfer to the alternate
source until adequate voltage and frequency are available.
The transfer switch provides a special circuit that de-energizes the motor
control circuit five (5) second prior to transfer in either direction to prevent
high current transients due to an out-of-phase condition between the
motor and the source to which it is being connected.
A contact is provided to actuate the engine starting circuit when normal
source fails. To prevent false starts, a time delay (factory set at 1/2 to 3
seconds) is provided between normal source failure and actuation of the
engine start contact.
An isolation switch ahead of the alternate source input terminals of the
transfer switch is provided. When the switch is opened, auxiliary contacts
in the generator start circuit prevent starting if commanded to by the
transfer switch. An additional auxiliary contact on the isolation switch is
provided for remote annunciation of isolation switch position.
An adjustable time delay (0-30 min.) prevents restoration to normal
service for a pre-set period of time to assure normal line stabilization.
An auxiliary N.O. contact is provided for remote annunciation of transfer
to emergency. This contact is operated by the transfer mechanism as a
direct indication of switch position.
Pilot lights for indication of Switch in Normal position, Switch in
Emergency position, and Emergency Isolation Switch in Off. Audible
indication of Emergency Isolation Switch in Off is also included.
A test switch is also provided which simulates loss of normal power so
that the transfer switch operation can be checked without interrupting
normal service to the fire pump controller.
MSC0212 v11
Power Transfer Switches
For Electric Motor Driven Fire Pumps
Electric Motor Fire Pump Controller with Automatic Transfer Switch
MODBUS Communication Protocol via RS485 Data logging:
Specifications port The controller shall have separate data logs for
storing system data that is readable through the OID.
The controller shall include the following standard All wiring terminals on PCB's shall be removable
type Pressure Log: The controller shall have a Pressure
features:
log with continuous pressure recording of 30 days of
NEMA Type 2 drip proof metal freestanding Automatic Transfer Switch: UL Listed for Fire data. The pressure log samples shall be time and
enclosure Pump Service, sized at least 115% of motor full date stamped and stored on a removable SD card
load current and shall conform to all requirements memory. The pressure log shall be searchable by
AUTO, MANUAL, TEST, and OFF mode
of NFPA 20 Chapter 10. It shall be installed in a each sample, by minute, or by hour. Each days
buttons illuminated with colored LED's for
controller mode operation barriered compartment of the fire pump entries shall be stored in a separate file on the SD
controller. The complete assembly, controller and card. SD memory shall be readable by any PC
Operator Interface Device (OID) with 4 lines by transfer switch, shall be shipped as a single unit. equipped with an SD memory card reader.
20 character display with large character backlit
The Transfer Switch shall be supplied with a Event Log: The event log shall be capable of storing
LCD capable of being read in both direct sunlight
special circuit to prevent higher than normal no less than 3000 events. These events shall
or dark lighting conditions
starting currents when transferring from one include, but is not limited to, any of the following
10 pushbuttons for easy screen navigation, system source to the other. This circuit shall deactivate events/alarms:
test, lamp test, alarm reset, and horn silencing the fire pump motor five (5) seconds prior to MOTOR QUIT FAULT
transfer in either direction. MOTOR OVERLOAD
Multicolored LED's for alarm and mode PHASE REVERSAL
annunciation Alternate Source Isolation Switch: Externally PUMP FAILED TO START
operable, quick break type sized at least 115% of LOW VOLTAGE
LEDs shall be labeled with removable labels to motor full load current. Auxiliary contacts on the
allow for easy field modification if additional HIGH VOLTAGE
isolation switch shall be interwired with the PRESSURE TRANSDUCER FAULT
alarms and/or language changes engine start contacts to prevent starting of the PUMP ON DEMAND
All controller settings shall be programmable engine should the isolation switch be in the open LOW DISCHARGE PRESSURE
through the OID and shall be protected by two position. Shall be front mounted and wired for HIGH DISCHARGE PRESSURE
password levels ease of maintenance and allowing the unit to be REMOTE START SIGNAL
mounted flush against a wall. DELUGE VALVE START
All features shall be enabled or disabled through LOW PUMP ROOM TEMPERATURE
Auxiliary alarms:
the OID, no jumpers or external wires shall be RESERVOIR LOW
As standard the controller shall include 6 discrete
needed or allowed to activate or de-activate a RESERVOIR EMPTY
auxiliary inputs, 9 form 'C' auxiliary relay outputs.
feature RESERVOIR HIGH
These auxiliary inputs and outputs are in addition to
The system status data shall be displayed on the those mandated by NFPA 20. All auxiliary inputs, FLOW METER ON
OID. The displayed items shall include: System outputs, and OID LED's shall be field programmable RELIEF VALVE OPEN
pressure, Phase to Phase (AB, BC, AC) voltage, through the OID. This permits a multitude of GAS DETECTION
Phase current (A, B, C), Current time and date, customizable controller configurations to meet each LOW SUCTION PRESSURE
Number of starts, Total motor run hours, installations unique needs without adding cost to the LOW FIREWATER PRESSURE
Displayed countdown timers for: Sequential controller. The use of jumpers, soldering, or other LOW PURGE PRESSURE
motor start and motor stop, Status of Automatic external components are not allowed. HIGH GEAR OIL TEMPERATURE
Stop Setting. LOW GEAR OIL PRESSURE
The user can select any 9 of the following auxiliary HIGH VIBRATION
Audible horn with silence feature for silencable alarms that can be programmed and recorded in the PUMP ROOM DOOR OPEN
alarms event/alarm logs and annunciated with an LED and
output relay contact for conditions such as: Alarm Log: The Alarm Log shall be a separate
Lamp test feature LOW PUMP ROOM TEMP subset of the event log and shall display the last 10
RESERVOIR LOW alarms recorded in the system.
English or Spanish languages selectable through RESERVOIR EMPTY
the OID Each event or alarm recorded in the either event log
RESERVOIR HIGH or alarm logs shall have the following data recorded
Microprocessor based logic with real time/date FLOW METER ON with the event/alarm:
clock capable of running a minimum of 14 days RELIEF VALVE OPEN
Time and Date of Event or Alarm
without AC power connected to controller and GAS DETECTION
System Pressure
non-volatile flash memory to permanently store LOW SUCTION PRESSURE
LOW HYDRAULIC PRESSURE Descriptive Text Message of the Event/Alarm
the continuous pressure log, event log, alarm log Motor Running Status
and all user changeable set points and system LOW FIREWATER PRESSURE
LOW PURGE PRESSURE Phase to Phase Volts
data. Battery backup of any kind not allowed.
LOW GEAR OIL PRESSURE Phase Amps
Input and output status LED's to provide visual HIGH VIBRATION The internal logic of the controller shall be capable
indication of each discrete input's or output's EMERGENCY POWER ON of operation in a temperature range of 4.4ºC to 40ºC
on/off status PUMP ROOM DOOR OPEN and high, non-condensing, humidity levels.
One RS485 Serial Port The controller shall be manufactured by Metron.
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax:
Hubbell Industrial 336-434-2801
Controls, | Email:
Inc. ‑ Metron salesmail@metroninc.com
Fire Pump ∙ www.metroninc.com
Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com MSC0213 123
Bulletin MP-MTS 01/11
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 124
Limited Service Controller
For Electric Motor Driven Pumps
Metron MTS Automatic Transfer Switches provide
operation of Limited Service Pump motors from an
alternate source of power when the normal source
fails. These transfer switches are a part of the
Limited Service pump controller; although mounted
in a separate compartment, they are factory
assembled, shipped and installed as a part of the
controller.
The combination Limited Service controller/ transfer
switch is listed by Underwriters Laboratories and
meets all the latest requirements of NFPA 20
Standard for Installation of Centrifugal Fire Pumps.
Use of this controller must be acceptable to the
authority having jurisdiction.
The MTS Automatic Transfer Switch is a
mechanically held double throw switch with a fast
acting drive mechanism. Operating coils are
momentarily energized from the source to which the
load is being transferred. The switch is interlocked
electrically and mechanically to prevent both
services from feeding the load at the same time.
The transfer switch is capable of manual (non-
electrical) operation.
MSC0212 v11
Standard and Optional Features
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied. MSC0213 180
HIGH VIBRATION
GAS DETECTION Options
EMERGENCY POWER ON Option H: Space Heater
PUMP ROOM DOOR AJAR If the ambient atmosphere is especially damp, a space
LOW INTAKE heater rated at 100 watts may be supplied to reduce
Data logging: moisture in the cabinet. A thermostat is supplied as standard
The controller includes two (2) separate data logs for storing with this option. A humidistat may be substituted if specified.
system data that is readable through the OID or copied to a Option T: Weekly Test Start Solenoid
computer equipped with an SD card reader. The 2 data logs In some cases it may be desirable to have the electric motor
are as follows: run at a preset time each week for approximately 30 minutes.
Pressure Log: The pressure log provides a continuous The controller includes a built in weekly test function. This
pressure record for 30 days. The pressure log samples shall option complements the standard function by simulating a
be time and date stamped and stored in a permanent non- loss of pressure. Simulation of pressure loss is
volatile SD memory card. The pressure log can be searched accomplished by opening a solenoid valve, which reduces
by each sample, by minute, or by hour through the OID. the system pressure below the starting pressure of the
controller.
Event Log: The event log will store up to 300 of the most
current events. These events can include, but are not limited Option W: Omit Legs
to, any of the following events/alarms: For systems where the controller is mounted on a common
PUMP RUNNING skid with the pump and motor, the legs of the controller may
POWER AVAILABLE be omitted, 3” (76.2mm) channels or wall mounting brackets
PHASE REVERSAL can be supplied. If specified, lifting eyes may also be
MOTOR OVERLOAD supplied.
REMOTE START Enclosure
LOCAL START The following NEMA type enclosures are also available: 3R,
PUMP ON DEMAND / FIRE CONDITION 4, 4X (Painted Cold Rolled Steel), 4X (304 or 316 Stainless
SYSTEM FAULT Steel), and 12
AUTO MODE
MANUAL MODE
OFF MODE MTS100A Power Transfer Switches
PRESSURE TRANSDUCER FAULT Motor HP Line Voltage Catalog Number
FAILED TO START 7.5-30 208-575 VAC / 3 Phase MTS100
LOW INTAKE SHUTDOWN 5-15 115-230 VAC / 1 Phase MTS100
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACT
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
HIGH VOLTS
LOW VOLTS
MSC0212 v11
Limited Service Controller
For Electric Motor Driven Pumps
Model MP30 Limited Service Across‑the‑line Start Electric Motor Controller with Dual Utility Transfer Switch
load current and shall conform to all Pressure Log: The controller shall have a Pressure
Specifications requirements of NFPA 20 Chapter 10. It shall
be installed in a barriered compartment of the
log with continuous pressure recording of 30 days
of data. The pressure log samples shall be time and
The Limited Service Controller shall include the fire pump controller. The complete assembly, date stamped and stored on a removable SD card
following standard features: controller and transfer switch, shall be shipped memory. The pressure log shall be searchable by
NEMA Type 2 drip proof metal freestanding as a single unit. each sample, by minute, or by hour. Each days
enclosure The Transfer Switch shall be supplied with a entries shall be stored in a separate file on the SD
AUTO, MANUAL, TEST, and OFF mode special circuit to prevent higher than normal card. SD memory shall be readable by any PC
buttons illuminated with colored LED's for starting currents when transferring from one equipped with an SD memory card reader.
controller mode operation source to the other. This circuit shall deactivate
Event Log: The event log shall be capable of
Operator Interface Device (OID) with 4 lines by the fire pump motor five (5) seconds prior to
storing no less than 3000 events. These events
20 character display with large character backlit transfer in either direction.
shall include, but is not limited to, any of the
LCD capable of being read in both direct Alternate Source Isolation Switch: Externally
following events/alarms:
sunlight or dark lighting conditions operable, quick break type sized at least 115% of
PUMP RUNNING
10 pushbuttons for easy screen navigation, motor full load current. Auxiliary contacts on
POWER AVAILABLE
system test, lamp test, alarm reset, and horn the isolation switch shall be inter-wired with the
PHASE REVERSAL
silencing engine start contacts to prevent starting of the
MOTOR OVERLOAD
Multicolored LED's for alarm and mode engine should the isolation switch be in the open
REMOTE START
annunciation position. Shall be front mounted and wired for
LOCAL START
LEDs shall be labeled with removable labels to ease of maintenance and allowing the unit to be
PUMP ON DEMAND / FIRE CONDITION
allow for easy field modification if additional mounted flush against a wall.
SYSTEM FAULT
alarms and/or language changes Auxiliary alarms: AUTO MODE
All controller settings shall be programmable As standard the controller shall include 6 discrete MANUAL MODE
through the OID and shall be protected by two auxiliary inputs, 9 form 'C' auxiliary relay outputs. OFF MODE
password levels These auxiliary inputs and outputs are in addition PRESSURE TRANSDUCER FAULT
All features shall be enabled or disabled through to those mandated by NFPA 20. All auxiliary FAILED TO START
the OID, no jumpers or external wires shall be inputs, outputs, and OID LED's shall be field LOW INTAKE SHUTDOWN
needed or allowed to activate or de-activate a programmable through the OID. This permits a SUPERVISORY POWER FAILURE
feature multitude of customizable controller configurations LOW PRESSURE
The system status data shall be displayed on the to meet each installations unique needs without AUTO WEEKLY TEST START
OID. The displayed items shall include: System adding cost to the controller. The use of jumpers, UNDER FREQUENCY
pressure, Phase to Phase (AB, BC, AC) voltage, soldering, or other external components are not OVER FREQUENCY
Phase current (A, B, C), Current time and date, allowed. LOW ZONE / HIGH ZONE CONTACT
Number of starts, Total motor run hours, HIGH DISCHARGE PRESSURE
Displayed countdown timers for: Sequential The user can select any 9 of the following auxiliary NO LOAD CONDITION
motor start and motor stop, Status of Automatic alarms that can be programmed and recorded in the HIGH VOLTS
Stop Setting. event/alarm logs and annunciated with an LED and LOW VOLTS
output relay contact for conditions such as: Alarm Log: The Alarm Log shall be a separate
Audible horn with silence feature for silencable
LOW PUMP ROOM TEMPERATURE subset of the event log and shall display the last 10
alarms
RESERVOIR LOW alarms recorded in the system.
Lamp test feature
RESERVOIR EMPTY
English or Spanish languages selectable through RESERVOIR HIGH Each event or alarm recorded in the either event log
the OID FLOW METER ON or alarm logs shall have the following data
Microprocessor based logic with real time/date RELIEF VALVE OPEN recorded with the event/alarm:
clock capable of running a minimum of 14 days LOW SUCTION PRESSURE Time and Date of Event or Alarm
without AC power connected to controller and HIGH PUMP ROOM TEMPERATURE System Pressure
non-volatile flash memory to permanently store LOW FIREWATER PRESSURE Descriptive Text Message of the Event/Alarm
the continuous pressure log, event log, alarm log LOW PURGE PRESSURE Motor Running Status
and all user changeable set points and system LOW GEAR OIL PRESSURE Phase to Phase Volts
data. Battery backup of any kind not allowed. HIGH GEAR OIL TEMPERATURE Phase Amps
Input and output status LED's to provide visual HIGH VIBRATION
indication of each discrete input's or output's GAS DETECTION The internal logic of the controller shall be capable
on/off status EMERGENCY POWER ON of operation in a temperature range of 4.4ºC to
One RS485 Serial Port PUMP ROOM DOOR AJAR 40ºC and high, non-condensing, humidity levels.
MODBUS Communication Protocol via RS485 LOW INTAKE
port The controller shall be manufactured by Metron.
All wiring terminals on PCB's shall be Data logging:
removable type The controller shall have separate data logs for
Automatic Transfer Switch: UL Listed for Fire storing system data that is readable through the
Pump Service, sized at least 115% of motor full OID.
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin M30/MTS 01/11182
MSC0213
Limited Service Controller
For Electric Motor Driven Pumps
These controllers are for use with squirrel
cage motors, 30 horsepower or less, 575
volts or less, across-the-line type starting
and must be acceptable to the authority
having jurisdiction. Limited Service
controllers are withstand rated and listed
by Underwriters Laboratories.
Construction of these controllers differs
from the Electric Fire Pump controllers in
that the manually operated isolation
switch is not supplied and the circuit
breaker is of the thermal-magnetic type.
MSC0212 v11
Standard and Optional Features
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied. MSC0213 189
HIGH VIBRATION
GAS DETECTION Options
EMERGENCY POWER ON Option H: Space Heater
PUMP ROOM DOOR AJAR If the ambient atmosphere is especially damp, a space
LOW INTAKE heater rated at 100 watts may be supplied to reduce
Data logging: moisture in the cabinet. A thermostat is supplied as
The controller includes two (2) separate data logs for standard with this option. A humidistat may be
storing system data that is readable through the OID substituted if specified.
or copied to a computer equipped with an SD card Option T: Weekly Test Start Solenoid
reader. The 2 data logs are as follows: In some cases it may be desirable to have the electric
motor run at a preset time each week for
Pressure Log: The pressure log provides a
approximately 30 minutes. The controller includes a
continuous pressure record for 30 days. The pressure
built in weekly test function. This option complements
log samples shall be time and date stamped and
the standard function by simulating a loss of pressure.
stored in a permanent non-volatile SD memory card.
Simulation of pressure loss is accomplished by
The pressure log can be searched by each sample, by
opening a solenoid valve, which reduces the system
minute, or by hour through the OID.
pressure below the starting pressure of the controller.
Event Log: The event log will store up to 300 of the Option W: Omit Legs
most current events. These events can include, but For systems where the controller is mounted on a
are not limited to, any of the following events/alarms: common skid with the pump and motor, the legs of the
PUMP RUNNING controller may be omitted, 3” (76.2mm) channels or
POWER AVAILABLE wall mounting brackets can be supplied. If specified,
PHASE REVERSAL lifting eyes may also be supplied.
MOTOR OVERLOAD
REMOTE START Enclosure
LOCAL START The following NEMA type enclosures are also
PUMP ON DEMAND / FIRE CONDITION available: 3R, 4, 4X (Painted Cold Rolled Steel), 4X
SYSTEM FAULT (304 or 316 Stainless Steel), and 12
AUTO MODE
MANUAL MODE
OFF MODE
PRESSURE TRANSDUCER FAULT
FAILED TO START
LOW INTAKE SHUTDOWN
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE
CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
HIGH VOLTS
LOW VOLTS
MSC0212 v11
Limited Service Controller
For Electric Motor Driven Pumps
Model MP30 Limited Service Across‑the‑line Start Electric Motor Pump Controller
changeable set points and system data. removable SD card memory. The pressure log
Specifications Battery backup of any kind not allowed.
Input and output status LED's to provide
shall be searchable by each sample, by minute,
or by hour. Each days entries shall be stored in a
visual indication of each discrete input's or separate file on the SD card. SD memory shall
General Controller Description output's on/off status be readable by any PC equipped with an SD
The Limited Service Controller shall be factory One RS485 Serial Port memory card reader.
assembled, wired and tested as a unit and shall MODBUS Communication Protocol via Event Log: The event log shall be capable of
conform to all requirements of the latest edition RS485 port storing no less than 3000 events. These events
of NFPA 20, NFPA 70 and be Third Party All wiring terminals on PCB's shall be shall include, but are not limited to, any of the
Listed by Underwriters Laboratories (UL). The removable type following events/alarms:
controller shall be available for 208, 230, 380- Service Entrance Rated PUMP RUNNING
415, 480 or 575 volt three phase power. POWER AVAILABLE
Auxiliary alarms
Controller Equipment Features PHASE REVERSAL
As standard the controller shall include 6 MOTOR OVERLOAD
The controller shall include the following discrete auxiliary inputs, 9 form 'C' auxiliary REMOTE START
standard features: relay outputs. These auxiliary inputs and LOCAL START
NEMA Type 2 drip proof metal freestanding outputs are in addition to those mandated by PUMP ON DEMAND / FIRE CONDITION
enclosure NFPA 20. All auxiliary inputs, outputs, and SYSTEM FAULT
Operator Interface Device (OID) with 4 lines OID screens shall be field programmable AUTO MODE
by 20 character display with large character through the OID. This permits a multitude of MANUAL MODE
backlit LCD capable of being read in both customizable controller configurations to meet OFF MODE
direct sunlight or dark lighting conditions each installations unique needs without adding PRESSURE TRANSDUCER FAULT
10 pushbuttons for easy screen navigation, cost to the controller. The use of jumpers, PUMP FAILED TO START
system test, lamp test, alarm reset, and horn soldering, or other external components are not LOW INTAKE SHUTDOWN
silencing allowed. SUPERVISORY POWER FAILURE
Multicolored LED's for alarm and mode LOW PRESSURE
The user can select any 9 of the following
annunciation AUTO WEEKLY TEST START
auxiliary alarms that can be programmed and
LEDs shall be labeled with removable labels UNDER FREQUENCY
recorded in the event log and annunciated with
to allow for easy field modification of an OID screen and output relay contact for OVER FREQUENCY
language changes LOW ZONE / HIGH ZONE CONTACTS
conditions such as but not limited to:
All controller settings shall be programmable HIGH DISCHARGE PRESSURE
LOW PUMP ROOM TEMP
through the OID and shall be protected by NO LOAD CONDITION
RESERVOIR LOW
two password levels HIGH VOLTS
RESERVOIR EMPTY
All features shall be enabled or disabled LOW VOLTS
RESERVOIR HIGH
through the OID, no jumpers or external wires FLOW METER ON Each event or alarm recorded in the event log
shall be needed or allowed to activate or de- RELIEF VALVE OPEN shall have the following data recorded with the
activate a feature LOW SUCTION PRESSURE event/alarm:
The system status data shall be displayed on HIGH PUMP ROOM TEMPERATURE Time and Date of Event or Alarm
the OID. The displayed items shall include: LOW FIREWATER PRESSURE System Pressure
System pressure, Phase to Phase (AB, BC, LOW PURGE PRESSURE Descriptive Text Message of the Event/Alarm
AC) voltage, Phase current (A, B, C), System LOW GEAR OIL PRESSURE Motor Running Status
Events and Notifications, Current time and HIGH GEAR OIL TEMPERATURE Phase to Phase Volts
date, Number of starts, Total motor run hours, GAS DETECTION
Phase Amps
Displayed countdown timers for: Sequential HIGH VIBRATION
motor start and motor stop, Status of EMERGENCY POWER ON The internal logic of the controller shall be
Automatic Stop Setting. PUMP ROOM DOOR AJAR capable of operation in a temperature range of
Audible horn with silence feature for LOW INTAKE 4.4ºC to 40ºC and high, non-condensing,
silencable alarms humidity levels.
Data logging
Lamp test feature
The controller shall be manufactured by Metron.
Foreign languages selectable through the OID The controller shall have separate data logs for
Microprocessor based logic with real storing system data that is readable through the
time/date clock capable of running a OID.
minimum of 14 days without AC power
Pressure Log: The controller shall have a
connected to controller and non-volatile flash
Pressure log with continuous pressure recording
memory to permanently store the continuous
of 30 days of data. The pressure log samples
pressure log, event log, alarm log and all user
shall be time and date stamped and stored on a
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin M30 01/11191
MSC0213
JOCKEY PUMP
ALARM PANELS
RESIDENTIAL
Contents:
FIRE PUMP
Model MS3 - Jockey Pump Controller
Alarm Panels
CONTROLLER
Remote Alarm Panel
Electric Remote Alarm Panel
DieselCONTENTS:
SECTION Engine Remote Alarm Panel
M15 Bulletin
Additive
M15Controllers
Price Sheets
Model M15 Drawings
MS3 Bulletin
Model FDF4-J - Diesel “Foam” Pump Controller
MS3 Price Sheets
Remote
Model Alarm Panel Bulletin
MPF30 - Electric “Foam” Pump Controller
Electric Remote Alarm Panel Price Sheet
Diesel Engine
Model Remote Alarm
MPF300 Panelthe
- Across Price SheetStart Electric
Line
Model 1701C Drawings
“Foam”
Model 1802B Pump Controller
Drawings
Residential Fire Pump Controller
RFP Price Sheet
RFP Drawings
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 195
M15 Series Jockey
Pump Controllers
M15 Series
Jockey Pump Controllers
The M15 Jockey (or make-up) Pump Controllers
are in the same system as the main fire pump
controller(s). Their purpose is to maintain normal
water pressure and to help prevent unnecessary
cycling of the main fire pump(s).
The M15 series jockey Pump Controllers are
listed to UL 508 Standard for Industrial Controls.
Each controller contains an externally operable
fused disconnect switch with fuses which are
horsepower rated, a motor contactor with
protective overload relay, and a door mounted
hand-off-auto switch all housed in a NEMA 2 drip
proof enclosure. As an option, a circuit breaker is
available in lieu of the fused disconnect
The M15A and M15B Jockey Pump Controllers
include a pressure switch with independent high
and low set points for automatic starting and
stopping. The pressure switch is piped to an
external 1/4 inch NPT connector.
The M15A incorporates a control power
transformer and run period timer.
The M15B omits the run period timer and the
control power transformer (transformer is
available as an optional adder)
Standard features of the M15A
• Externally operable disconnect
• Horsepower rated fuses
• Hand-Off-Auto selector switch
• Pressure switch (4.5 - 232 PSI)
• Control power transformer
• Minimum run period timer
• NEMA 2 enclosure
NFPA / LPC / EN
of a whole linee of successsful productts.
This unit feaatures statte-of-the art a
microocontroller devices,
d dessigned arounnd
the laatest UL staandards. Thee unit offers a
comppact, robustt and reliaable producct,
offeriing a great deal
d more fllexibility thaan
its prredecessors.
It features
f 6 channel monitoring,
16
desiggned primarrily for use with thhe
Metroon range of fire puump control
systemms, providinng remote supervision
s o
of
compplete installaations from any manneed
pointt. (for exam mple; gate houses annd
This will
w be the case for inttermittent, or o
recepption points)
infreqquent alarm states, or faults whicch
The features in this modell include DIP have been
b clearedd. Channels that
t remain in i
switcches which enables
e bankks of inputs to the alaarm state, hoowever, willl return to thhe
be coonfigured on n site for acctive high/loow activee flashing sttate, soundinng the alarm m
operaation, smalleer footprint, and attractivve once more.
m
packaaging in a style
s that will
w blend innto
A Laamp test faacility is inncluded. Thiis
most environmments witthout beinng
versioon also now has a more cost effectivve
intrussive, yet imp
possible to iggnore when an
integral battery baack up and charger optioon
alarm
m state is trig
ggered.
along with a new w low cost repeat alarm m
The indicators are identiffied by tw wo outputt-card.
removable chann nel allocationn labels. Theese
labelss may be pre-printed to order by b
Metroon, or you maym decide to legend thhe
panell yourself on site. One O label is
intended for chaannel allocaation and thhe
otherr for zone infformation.
Whenn in an alarmm state, the unit
u will sounnd
the alarm,
a and flash the correspondinng
indicator on the front panel, in order to
alert the operatorr. Depressingg the ‘MUTE E’
button will silennce the alarrm and activve
channnel indicatoors will ceease to flassh,
holdiing steady in
n the ‘ON’ state.
s Pressinng
the ‘R
RESET’ buttton will retuurn all inactivve
fault channels to the ‘STAND DBY’ state,
clear the correspoonding indiccators.
Hubbeell Industrial Co
ontrols, Inc. ‑ Metron
M Fire Pum
mp Control Divvision | 4301 Cheeyenne Dr., Archhdale, NC 272663
HubbellPhone:
Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
336-434-2800 · Fax: 336-434-22801 | Email: sallesmail@metronninc.com · www..metroninc.com
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.comBulleetin RAP 01/11
MSC0213 204
Remote Alarm Panels
For Fire Pump Controllers
Maximum power <300mA
rating
Power supply 12v D.C./240v A.C.
(selectable 110v)
Dimensions 10.3 in wide x 8 in high
x 4.5 in deep
Enclosure Mild steel, wall
mounting
Inputs 16, 12v digital
16 l.e.d. indicators,
plus A.C. status
indicator.
Weight 6.5lbs approx.
120v/110V 240v/230V
Hubbell Industrial Controls, Inc. ‑ Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
HubbellPhone:
Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
336-434-2800 · Fax: 336-434-2801 | Email: salesmail@metroninc.com · www.metroninc.com
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.comBulletin RAP 01/11
MSC0213 205
Additive Pump Controller
Diesel Engine Additive “Foam” Pump Controller
MSC0212 v11
Standard and Optional Features
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied. MSC0213 211
Diesel Engine Additive Pump Controller
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 212
Additive Pump Controller
Diesel Engine Additive “Foam”Pump Controller
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax:
Phone: 336-434-2800 336-434-2801
∙ Fax: 336-434-2801 || Email:
Email:salesmail@metroninc.com
salesmail@metroninc.com ∙ www.metroninc.com
∙ www.metroninc.com
Bulletin FDF4-J 01/11213
MSC0213
Limited Service Controller
Electric Additive “Foam” Pump Controller
These controllers are for use with squirrel cage
motors, 30 horsepower or less, 575 volts or less,
across-the-line type starting and must be
acceptable to the authority having jurisdiction.
Limited Service controllers are withstand rated
and listed by Underwriters Laboratories.
Construction of these controllers differs from the
Electric Additive Pump controllers in that the
manually operated isolation switch is not
supplied and the circuit breaker is of the thermal-
magnetic type.
An internal variable has been added to
control the pressure relieving dump valve.
The dump valve contact must be supplied
with an external power source for
operation of the valve. The dump valve
contact will close upon the controller
receiving a start command such as a
pressure drop or deluge valve signal. The
dump valve will remain open after the
engine starts for approximately 10
seconds.
The controller is completely wired, assembled,
and tested at the factory before shipment, and
ready for immediate installation.
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
All photographs and graphics are typical and may not represent actual product supplied. MSC0213 215
Electric Additive “Foam” Pump Controller
HIGH VIBRATION
GAS DETECTION Options
EMERGENCY POWER ON Option H: Space Heater
PUMP ROOM DOOR AJAR If the ambient atmosphere is especially damp, a space
LOW INTAKE heater rated at 100 watts may be supplied to reduce
Data logging: moisture in the cabinet. A thermostat is supplied as
The controller includes two (2) separate data logs for standard with this option. A humidistat may be
storing system data that is readable through the OID substituted if specified.
or copied to a computer equipped with an SD card Option T: Weekly Test Start Solenoid
reader. If the controller is set for non pressure In some cases it may be desirable to have the electric
actuation there will not be any pressure logs provided. motor run at a preset time each week for
The 2 data logs are as follows: approximately 30 minutes. The controller includes a
built in weekly test function. This option complements
Pressure Log: The pressure log provides a
the standard function by simulating a loss of pressure.
continuous pressure record for 30 days. The pressure
Simulation of pressure loss is accomplished by
log samples shall be time and date stamped and
opening a solenoid valve, which reduces the system
stored in a permanent non-volatile SD memory card.
pressure below the starting pressure of the controller.
The pressure log can be searched by each sample, by
minute, or by hour through the OID. This feature can Option W: Omit Legs
be toggled on/off. For systems where the controller is mounted on a
common skid with the pump and motor, the legs of the
Event Log: The event log will store up to 300 of the controller may be omitted, 3” (76.2mm) channels or
most current events. These events can include, but wall mounting brackets can be supplied. If specified,
are not limited to, any of the following events/alarms: lifting eyes may also be supplied.
PUMP RUNNING
POWER AVAILABLE Enclosure
PHASE REVERSAL The following NEMA type enclosures are also
MOTOR OVERLOAD available: 3R, 4, 4X (Painted Cold Rolled Steel), 4X
REMOTE START (304 or 316 Stainless Steel), and 12
LOCAL START
PUMP ON DEMAND / FIRE CONDITION
SYSTEM FAULT
AUTO MODE
MANUAL MODE
OFF MODE
PRESSURE TRANSDUCER FAULT
FAILED TO START
LOW INTAKE SHUTDOWN
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
HIGH VOLTS
LOW VOLTS
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 216
Additive Pump Controller
Electric Additive “Foam” Pump Controller
Metron Additive Pump Controllers conform to the latest
requirements of Chapter 10, National Fire Protection
Association Pamphlet 20, Standard for Centrifugal Fire
Pumps as adopted by Underwriters Laboratories and
Factory Mutual. They are withstand rated and listed by
Underwriters’ Laboratories and approved by Factory Mutual
Research Corporation.
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 218
All photographs and graphics are typical and may not represent actual product supplied.
Electric Additive “Foam” Pump Controller
GAS DETECTION
HIGH VIBRATION Options
EMERGENCY POWER ON
PUMP ROOM DOOR OPEN Option H: Space Heater
If the ambient atmosphere is especially damp, a
Data logging: space heater rated at 100 watts may be supplied to
The controller includes separate data logs for storing reduce moisture in the cabinet. A thermostat is
system data that is readable through the OID or supplied as standard with this option. A humidistat
copied to a computer equipped with an SD card may be substituted if specified.
reader. If the controller is set for non pressure
Option W: Omit Legs
actuation there will not be any pressure logs provided.
For systems where the controller is mounted on a
The data logs are as follows:
common skid with the pump and motor, the legs of
Pressure Log: The pressure log provides a the controller may be omitted, 3” (76.2mm) channels
continuous pressure record for 30 days. The or wall mounting brackets can be supplied. If
pressure log samples shall be time and date stamped specified, lifting eyes may also be supplied.
and stored in permanent non-volatile SD memory
Enclosure
card. The pressure log can be searched by each
The following NEMA type enclosures are also
sample, by minute, or by hour through the OID.(Not
available: 3R, 4, 4X (Painted Cold Rolled Steel), 4X
used on remote applications).
(304 or 316 Stainless Steel), and 12
Event Log: The event log will store up to 300 of the
most current events. These events can include, but is
not limited to, any of the following events/alarms:
PUMP RUNNING
POWER AVAILABLE
PHASE REVERSAL
MOTOR OVERLOAD
REMOTE START
LOCAL START
PUMP ON DEMAND
SYSTEM FAULT
PRESSURE TRANSDUCER FAULT
PUMP FAILED TO START
LOW INTAKE SHUTDOWN ALARM
SUPERVISORY POWER FAILURE
LOW PRESSURE
AUTO WEEKLY TEST START
UNDER FREQUENCY
OVER FREQUENCY
LOW ZONE / HIGH ZONE CONTACTS
HIGH DISCHARGE PRESSURE
NO LOAD CONDITION
Hubbell Industrial Controls, Inc. - Metron Fire Pump Control Division | 4301 Cheyenne Dr., Archdale, NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
MSC0213 219
Additive Pump Controller
Electric Additive “Foam” Pump Controller
Model MPF300 Across‑the‑line Start Microprocessor Electric Motor Additive “Foam” Pump Controller
permanently store the continuous pressure log, Pressure Log: The controller shall have a
Specifications event log, alarm log and all user changeable
set points and system data. Battery backup of
Pressure log with continuous pressure recording
of 30 days of data. The pressure log samples
any kind not allowed. shall be time and date stamped and stored on a
General Controller Description Input and output status LED's to provide visual removable SD card memory. The pressure log
The Additive Pump Controller shall be factory indication of each discrete input's or output's shall be searchable by each sample, by minute, or
assembled, wired and tested as a unit and shall on/off status by hour. Each days entries shall be stored in a
conform to all requirements of the latest edition Internal variable to control dump valve. separate file on the SD card. SD memory shall be
of NFPA 20, NFPA 70 and be Third Party Listed • Ability to turn on/off pressure display. readable by any PC equipped with an SD
by Underwriters Laboratories (UL) and One RS485 Serial Port memory card reader.
Approved by Factory Mutual (FM). The MODBUS Communication Protocol via Event Log: The event log shall be capable of
controller shall be available for 208, 230, 380- RS485 port storing no less than 3000 events. These events
415, or 480 volt three phase power. Internal variable to controle dump valve. shall include, but is not limited to, any of the
Service Entrance Rated following events/alarms:
Controller Equipment Features
PUMP RUNNING
Ability to turn on/off pressure display and
The controller shall include the following POWER AVAILABLE
logging.
standard features: PHASE REVERSAL
NEMA Type 2 drip proof metal freestanding Auxiliary alarms MOTOR OVERLOAD
enclosure REMOTE START
As standard the controller shall include 6 discrete LOCAL START
Stainless steel plumbing.
auxiliary inputs, 9 form 'C' auxiliary relay PUMP ON DEMAND
Operator Interface Device (OID) with 4 lines
outputs. These auxiliary inputs and outputs are SYSTEM FAULT
by 20 character display with large character
in addition to those mandated by NFPA 20. All PRESSURE TRANSDUCER FAULT
backlit LCD capable of being read in both
auxiliary inputs, outputs, and OID screens shall PUMP FAILED TO START
direct sunlight or dark lighting conditions
be field programmable through the OID. This LOW INTAKE SHUTDOWN ALARM
10 pushbuttons for easy screen navigation, permits a multitude of customizable controller
system test, lamp test, alarm reset, and horn SUPERVISORY POWER FAILURE
configurations to meet each installations unique LOW PRESSURE
silencing needs without adding cost to the controller. The
Multicolored LED's for alarm and mode AUTO WEEKLY TEST START
use of jumpers, soldering, or other external UNDER FREQUENCY
annunciation components are not allowed.
LEDs shall be labeled with removable labels OVER FREQUENCY
to allow for easy field modification of The user can select any 9 of the following LOW ZONE / HIGH ZONE CONTACTS
language changes auxiliary alarms that can be programmed and HIGH DISCHARGE PRESSURE
All controller settings shall be programmable recorded in the event log and annunciated with NO LOAD CONDITION
through the OID and shall be protected by two an OID screen and output relay contact for Each event or alarm recorded in the event log
password levels conditions such as but not limited to: shall have the following data recorded with the
All features shall be enabled or disabled LOW PUMP ROOM TEMP event/alarm:
through the OID, no jumpers or external wires RESERVOIR LOW Time and Date of Event or Alarm
shall be needed or allowed to activate or de- RESERVOIR EMPTY
System Pressure
activate a feature RESERVOIR HIGH
Descriptive Text Message of the Event/Alarm
The system status data shall be displayed on FLOW METER ON
RELIEF VALVE OPEN Motor Running Status
the OID. The displayed items shall include: Phase to Phase Volts
System pressure, Phase to Phase (AB, BC, LOW SUCTION PRESSURE
HIGH PUMP ROOM TEMPERATURE Phase Amps
AC) voltage, Phase current (A, B, C), System
Events and Notifications, Current time and LOW FIREWATER PRESSURE The internal logic of the controller shall be
date, Number of starts, Total motor run hours, LOW PURGE PRESSURE capable of operation in a temperature range of
Displayed countdown timers for: Sequential LOW GEAR OIL PRESSURE 4.4ºC to 40ºC and high, non-condensing,
motor start and motor stop, Status of HIGH GEAR OIL TEMPERATURE humidity levels.
Automatic Stop Setting. GAS DETECTION
HIGH VIBRATION The controller shall be manufactured by Metron.
Audible horn with silence feature for
silencable alarms EMERGENCY POWER ON
Lamp test feature PUMP ROOM DOOR OPEN
Foreign languages selectable through the OID Data logging
Microprocessor based logic with real time/date
clock capable of running a minimum of 14 The controller shall have separate data logs for
days without AC power connected to storing system data that is readable through the
controller and non-volatile flash memory to OID.
HubbellHubbell
Industrial Controls,
Industrial Inc.Inc.
Controls, - Metron
‑ MetronFire
FirePump Control
Pump Control Division
Division | 4301
| 4301 Cheyenne
Cheyenne Dr., Archdale,
Dr., Archdale, NC 27263 NC 27263
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com
Phone: 336-434-2800 ∙ Fax: 336-434-2801 | Email: salesmail@metroninc.com ∙ www.metroninc.com Bulletin MPF300 01/11
MSC0213 220