Вы находитесь на странице: 1из 4

Timers

Multifunction
Types DMB51, DMB71
• Selectable time range 0.1 s to 100 h
• 7 knob selectable functions:
Op - delay on operate
In - interval
Io - interval on trigger open
Id - double interval
Dr - delay on release
R - symmetrical recycler ON first
Rb - symmetrical recycler OFF first
• Automatic or manual start
• Repeatability: ≤ 0.2%
• Output: 5 A SPDT or 5 A DPDT relays
• For mounting on DIN-rail in accordance with DIN/EN 50 022
DMB51 DMB71 • 17.5 mm (DMB51C) or 35.5 mm (DMB71D) DIN-rail
housing (DIN 43880)
• Combined AC and DC power supply
• LED indication for relay status and power supply ON

Product Description Ordering Key DMB 51 C M24


Multi-voltage timer with 7 for DPDT version, suitable Housing
knob-selectable functions both for back and front panel Function
and 7 knob-selectable time mounting. Type
ranges within 0.1s and 100h. Wide power supply range: Item number
For mounting on DIN-rail. 24 VDC and 24 to 240 VAC Output
Housing 17.5 mm wide for or 12 to 240 VAC/DC. Power supply
SPDT version and 35.5 mm

Type Selection
Mounting Output Housing Supply: Supply:
12 to 240 VAC/DC 24 VDC and 24 to 240 VAC

DIN-rail SPDT Mini-D DMB 51 C W24 DMB 51 C M24


DIN-rail DPDT Mini-D DMB 71 D W24 DMB 71 D M24

Time Specifications Output Specifications


Time ranges Output SPDT or DPDT relay
Knob selectable 0.1 to 1 s Rated insulation voltage 250 VAC (rms)
1 to 10 s
6 to 60 s Contact Ratings (AgSnO2) µ
60 to 600 s Resistive loads AC 1 5 A @ 250 VAC
0.1 to 1 h DC 12 5 A @ 24 VDC
1 to 10 h Small inductive loads AC 15 2.5 A @ 250 VAC
10 to 100 h DC 13 2.5 A @ 24 VDC
Setting accuracy ≤ 5% Mechanical life ≥ 30 x 106 operations
Repeatability ≤ 0.2% Electrical life ≥ 105 operations
(at 5 A, 250 V, cos ϕ = 1)
Time variation
Within rated power supply ≤ 0.05%/V Operating frequency < 7200 operations/h
Within ambient temperature ≤ 0.2%/°C Dielectric strength
Reset Dielectric voltage 2 kVAC (rms)
Manual reset of time and/or Close the trigger contact Rated impulse withstand
relay between pins A1 and Y1 voltage 2.5 kV (1.2/50 µs)
Pulse duration ≥ 100 ms
Power supply interruption ≥ 200 ms
Automatic start Connect pins A1 and Y1

Specifications are subject to change without notice (13.10.04) 1

Gross Automation (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomation.com


DMB51, DMB71

Supply Specifications General Specifications


Power supply Overvoltage cat. II Power ON delay ≤ 100 ms
Rated operational voltage (IEC 60664, IEC 60038) Indication for
through terminals: Power supply ON LED, green
(DMB51C) A1, A2 M24: 24 VDC ± 15% and Output relays ON LED, yellow
24 to 240 VAC + 10% -15%, (flashing when timing)
45 to 65 Hz
W24: 12 to 240 VDC + 10% -15% Environment (EN 60529)
and Degree of protection IP 20
12 to 240 VAC Pollution degree 2 (IEC 60664)
+ 10% -15%, 45 to 65 Hz Operating temperature -20° to +60°C, R.H. < 95%
(DMB71D) A1, A2 M24: 24 to 240 VDC + 10% -15% Storage temperature -30° to +80°C, R.H. < 95%
24 to 240 VAC + 10% -15%, Housing dimesions
45 to 65 Hz (DMB51C) 17.5 x 81 x 67.2 mm
W24 12 to 240 VDC + 10% -15% (DMB71D) 35.5 x 81 x 67.2 mm
and Weight 75 g
12 to 240 VAC +10% -15%, Screw terminals
45 to 65 Hz Tightening torque Max. 0.5 Nm according to
Voltage interruption ≤ 10 ms IEC EN 60947
Rated operational power Approvals UL, CSA (DMB 51 only),
(DMB51C) AC supply: 4 VA RINA (DMB 51 only)
DC supply: 1.5 W CE Marking Yes
(DMB71D) AC supply 5.5 VA
DC supply 2W EMC Electromagnetic Compatibillity
Immunity According to EN 61000-6-2
Emissions According to EN 50081-1
Time Setting
Upper knob: Centre knob:
Setting of function: Time setting on relative scale:
Op - delay on operate 1 to 10 with respect to the
In - interval chosen range.
Io - interval on trigger open
Lower knob:
Id - double interval
Setting of time range
Dr - delay on release
R - symmetrical recycler
(ON first)
Rb - symmetrical recycler
(OFF first)

Mode of Operation
Function Op the end of this period or is opened before the end of the second time period the
Delay on operate when the power supply is the delay time the relay device resets and the first
The time period begins as disconnected. The relay keeps ON and a new time time period begins again.
soon as the trigger contact operates again when the trig- period begins.
is closed. ger contact is closed again. If Function Dr
At the end of the set delay the trigger contact is closed Function Id Delay on release
time the relay operates and before the end of the delay Double interval The relay operates as soon
does not release until the time, the device resets and a The relay operates and the as the trigger contact is
trigger contact is closed new time period starts. time period begins as soon closed. The time period
again or the power supply is as the trigger contact is begins when the trigger con-
disconnected. If the trigger Function Io closed. The relay releases at tact is opened. The relay
contact is closed before the Interval on trigger open the end of this period or releases at the end of the
end of the delay time, the The relay operates and the when the power supply is set delay time or when the
device resets and a new time period begins as soon disconnected. When the power supply is disconnect-
time period starts. as the trigger contact is trigger contact is opened ed. The relay operates again
opened. At the end of the the relay operates again for when the input contact is
Function In set delay or when the power the set delay period. If the closed again. If it is opened
Interval supply is disconnected the trigger contact is opened before the end of the delay
The relay operates and the relay releases. The relay before the end of the first time the relay keeps ON, a
time period begins as soon operates again when the time period the second one new time period begins as
as the trigger contact is trigger contact is opened begins; if the trigger contact soon as the contact is
closed. The relay releases at again. If the trigger contact is closed before the end of closed again.

2 Specifications are subject to change without notice (13.10.04)

Gross Automation (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomation.com


DMB51, DMB71

Mode of Operation (cont.)


Function R Function Rb Additional Load Yellow LED working
Symmetrical recycler, ON- Symmetrical recycler, It's possible to wire an addi- mode
time period first OFF-time period first tional load (i.e. a relay) Timing: Slow blinking
The relay operates and the The time period begins as between pins Y1 and A2, Relay ON: See operation
time period begins as soon soon as the input contact is driven by the trigger contact diagrams
as the input contact is closed. The relay is OFF without damaging the
closed. After the set delay during the set delay period, device. Incorrect knobs position:
period the relay releases for after this time it operates for Fast blinking
the same time period. This the same time period. This
sequence continues with sequence continues with
equal ON- and OFF-time equal OFF- and ON-time
periods until the power sup- periods until the power sup-
ply is interrupted. ply is interrupted.

Wiring Diagram

L(+)
µ µ
A1 16 18 26 28
S

Y1

A2 15 25
DMB51CM... DMB71DM...
DMB51CW... DMB71DW...
DMB71DM...
N(-)
DMB71DW...

Operating Diagrams
Function Op - Delay on operate - Manual start Function In - Interval - Manual start

Power supply Power supply

Trigger input Trigger input

ON T T ON T T
Relay ON Relay ON
OFF OFF

LED LED

Function Op - Delay on operate - Automatic start Function In - Interval - Automatic start

Power supply Power supply

ON T T ON T T
Relay ON Relay ON
OFF OFF

LED LED

Specifications are subject to change without notice (13.10.04) 3

Gross Automation (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomation.com


DMB51, DMB71

Operating Diagrams (cont.)


Function Io - Interval on trigger open Function Id - Double interval

Power supply Power supply

Trigger input Trigger input

ON T T ON T T
Relay ON Relay ON

OFF OFF

LED
LED

Function Dr - Delay on release Function R - Symmetrical recycler (ON first)

Power supply Power supply

Trigger input Trigger input

ON T ON T T T T
Relay ON Relay ON
OFF OFF

LED LED

Function Rb - Symmetrical recycler (OFF first)

Power supply

Trigger input

ON T T T T
Relay ON
OFF

LED

Dimensions
DMB51 DMB71
17.5 35.5 67.2
67.2

18.7
18.7
81

81

45
45

2
2

4 Specifications are subject to change without notice (13.10.04)

Gross Automation (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomation.com

Вам также может понравиться