Вы находитесь на странице: 1из 196

140107_Regen.

indd 2 1/12/2010 9:07:07 AM


Regenerative Principle
The impeller blades passing the inlet port draw air or
Rotation other gases into the blower. The impeller blades then,
by centrifigal action, accelerate the air outward and
forward. Here the “regenerative” principle takes effect
as the air is turned back by the annular shaped hous-
ing to the base of the following blades, where it is
again hurled outward. Each “regeneration” imparts
more pressure to the air. When the air reaches the
stripper section at the outlet (the stripper is the part of
the blower located between the inlet and the outlet in
which the annulus is reduced in size to fit closely to the
sides and tips of the impeller blades), the air is
“stripped” from the impeller and diverted out of the
blower. The pressures or vacuums generated by each
Out spinning, non-contacting, oil-free impeller are equal to
those obtained by many larger multi-stage or positive
In displacement blowers.
Air Flow

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Table of Contents

A: Nine Major Blower Application Areas DR P15 C57


40.0 / 60.0 HP Regenerative Blower
B: Product Dimensional Listing
DR S15 C59
C: Industrial / Chemical Processing Blowers 40.0 HP High Pressure Regenerative Blower

DR 068 C1
D: Environmental / Chemical Processing Blowers
.125 HP Regenerative Blower

EN 101 & CP 101 D1
DR 083 C3
.5 HP Sealed Regenerative w/Explosion-Proof Motor
.125 HP Regenerative Blower
EN 303 & CP 303 D3
DR 101 & CP 101 C5
.5 HP Sealed Regenerative w/Explosion-Proof motor
.33 HP Regenerative Blower
EN 404 & CP 404 D5
DR 202 & CP 202 C7
1.0 HP Sealed Regenerative w/Explosion-Proof Motor
.33 HP Regenerative Blower
EN 454 & CP 454 D7
DR 303 & CP 303 C9
1.5 HP Sealed Regenerative w/Explosion-Proof Motor
.33 HP Regenerative Blower
EN 505 & CP 505 D9
DR 353 & CP 353 C11 2.0 / 2.5 HP Sealed Regenerative w/Explosion-Proof Motor
.75 HP Regenerative Blower
EN 513 & CP 513 D11
DR 404 & CP 404 C13 1.5 HP Sealed Regenerative w/Explosion-Proof Motor
1.0 HP Regenerative Blower
EN 523 & CP 523 D13
DR 454 & CP 454 C15 3.0 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor
1.5 HP Regenerative Blower EN 6 & CP 6 D15
DR 505 & CP 505 C17 5.0 HP Sealed Regenerative w/Explosion-Proof Motor
2.0 / 3.0 HP Regenerative Blower EN & CP 633 D17
DR 513 & CP 513 C19 7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor
1.5 HP Regenerative Blower EN 656 & CP 656 D19
DR 523 & CP 523 C21 3.0 HP Sealed Regenerative w/Explosion-Proof Motor
3. HP High Pressure Regenerative Blower EN 757 Single-Phase and CP Options D21
DR 555 & CP 555 C23 Sealed Regenerative Blower w/Explosion-proof Motor
3.0 / 4.0 HP Regenerative Blower EN 757 & CP 757 D23
DR 6 & CP 6 C25 3.0 / 5.0 HP Sealed Regenerative w/Explosion-Proof Motor
3.0 / 5.0 HP Regenerative Blower EN 808 Single-Phase and CP Options D25
DR 633 & CP 633 C27 Sealed Regenerative Blower w/Explosion-proof Motor
3.0 / 4.0 / 5.0 HP Regenerative Blower EN 808 & CP 808 Three-Phase D27
DR 656 & CP 656 Sealed Regenerative Blower w/Explosion-proof Motor
C29
3.0 / 4.0 / 5.0 HP Regenerative Blower EN 833 & CP 833 D29
DR 757 & CP 757 C31 7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor

4.0 / 5.0 HP Regenerative Blower EN 858 & CP 858 D31


DR S7 C33 7.5 / 10.0 HP Sealed Regenerative w/Explosion-Proof Motor

7.5 HP High Pressure Regenerative Blower EN 909 & CP 909 D33


DR 808 & CP 808 C35 10.0 / 15.0 HP Sealed Regenerative w/Explosion-Proof Motor

5.0 / 7.5 HP Regenerative Blower EN 979 & CP 979 D35


DR 833 & CP 833 C37 20.0 HP Sealed Regenerative w/Explosion-Proof Motor

7.5 / 10.0 HP Regenerative Blower EN 14 & CP 14 D37


DR 858 & CP 858 C39 20.0 / 30.0 HP Sealed Regenerative w/Explosion-Proof Motor

7.5 / 10.0 HP Regenerative Blower E: Remote Drive (Motorless) Blowers


DR P9 C41 MF573RD E1
15.0 / 20.0 HP Regenerative Blower
SL2RD E2
DR S9 C43 DR/EN/CP 404RD E3
15.0 / 20.0 HP High Pressure Regenerative Blower
DR/EN/CP 505RD E4
DR 909 & CP 909 C45 DR/EN/CP 513RD E5
10.0 / 15.0 HP Regenerative Blower
DR/EN/CP 523RD E6
DR 979 & CP 979 C47 DR/EN/CP 6RD E7
15.0 / 20.0 HP Regenerative Blower
DR/EN/CP 656RD E8
DR 1233 & CP 1233 C49 DR/EN/CP 757RD E9
20.0 HP High Pressure Regenerative Blower
DR/EN/CP 858RD E10
DR P13 C51 DR/EN/CP 909RD E11
20.0 / 30.0 HP Regenerative Blower
DR/EN/CP 979RD E12
DR S13 DR/EN/CP 1233RD E13
C53
20.0 / 30.0 HP High Pressure Regenerative Blower
DR/EN/CP 14RD E14
DR 14 & CP 14 C55
20.0 / 25.0 / 30.0HP Regenerative Blower

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Table of Contents

F: Application Specific Blowers


Minispiral F1
Insrument Grade Regenerative Blower
Minispiral MDC F3
Variable Flow Regenerative Blower
Minispiral 12/24V HDC F5
Variable Flow Regenerative Blower
Minispiral 12V HDC Extra Flow / Extra Wide Fat Boy F7
Variable Flow Regenerative Blower
SPIRAL Simplex SL2 F9
Insrument Grade Regenerative Blower
SPIRAL Duplex SL4 F11
Insrument Grade Regenerative Blower
SPIRAL Duplex SL5 F13
Insrument Grade Regenerative Blower
Nautilair F15
DR 404/454/505/513/656 F17
Spa Blowers
DR 10RDNT/SS10RDNT/HS 10RDNT F19
Remote Drive (Motorless) Blowers
MD 101 Magnetic-Drive F21
Regenerative Blower
GVR313 F23
Regenerative Blower

G: Accessories
Filtration - Inlet Filter (Single Connection) G1
Filtration - Inline Filter (Dual Connection) G2
Filtration - Filter Silencers (Single Connection) G3
Filtration - Filter Element G4
Filtration - Moisture Separator G5
Measurement - Air Flow Meter G7
Measurement - Digital Flowmeter G9
Noise Reduction - Sound Attenuating Enclosure G10
Noise Reduction - Inlet/Outlet Muffler (Single Connection) G11
Noise Reduction - Inline Muffler (Dual Connection) G12
Protection - Relief Valve - Mechanical G13
Protection - Pressure Regulating Diaphram Valve G14
Protection - Gauges G15
System - Variable Frequency Drive G16
System - Air Knives G17
System - 5 Way, 3 Port, 2 Position Diverter Valve G19
System - Air Flow Switch G21
Pressure & Vacuum Arrangements G22
H: Motor Blower Options
I: Application Engineering Basics

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Nine Major Blower Application Areas

Your own imagination and knowledge are probably the best source of in-plant and on-site applications for ROTRON regenerative blowers. This guide will help to
pinpoint and stimulate your consideration of the many alternative sources we provide to replace costly and maintenance intensive suction and pressure units
and systems. The nine major application groups are listed and a cross reference of the most common applications by industry will help you identify both
identical and similar applications in your industrial operations.

Application 1: Air-Assisted Breathing


Manufacturing
PARP Respiration

Mining
PARP Respiration

Nose Mouth Throat

Application 2: Air-Assisted Inflation or Support


Part Material Handling
Air Slides
Air Tables
Carbon Black Car Unloading
Blower
Paper Processing
Flotation Tables
Flotation Tables Forming Bar
Sheet Fluttering
Air Bags Air Film Support
Web Turn Bars

Textile
Garment Flotation Tables

Water Pollution Control


Pollution Containment
Air Slides / Air Tables Turning & Forming Bars Waterway Management

Application 3: Air-Assisted Vacuum Pick-Up or Hold-Down


Work Manufacturing
Plenum Bag Filling Equipment
Pneumatic Cutting Tables
Suction Cups
Blower Work Table Packaging Equipment
Work Blower Vacuum Manipulators
General Parts Pick-Up General Parts Hold-Down Corrugated and Paperboard Boxes
Flexible Packaging - Paper, Plastic, Aluminum Foil,
Block Textile Packaging and Steel Strapping
Rigid Packaging
Beverage Containers
Cosmetic and Toiletry Containers
Blister Packs
Blower Pharmaceutical Packaging
Food Packaging
Blower Box Sterile Medical Device Packaging
Vacuum Manipulator Flotation Tables Labels
Pressure Sensitive Tape

Paper or Plastics Handling


Cutting Tables
Diaper Making Equipment
Printing Presses

Blower Textile
Garment Cutting Tables
Yarn Guiding and Tensioning
Carboard Case Erector Yarn Aspiration

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 A1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Nine Major Blower Application Areas

Application 4: Air & Gas Sampling, Boosting, or Circulating


Air Pollution Control Pharmaceutical
Stack Air Sampling Clean Room Air Circulation
Air Stream Release Monitoring Oxygen Generator
Lens Lens
Fire Prevention Air Sampling
Light Beam
Flue Gas Sampling Plastics Handling
Desiccant Dryer Bed Regeneration
Foundry
Blower Blower
Blower Combustion Air Boost
Fluid Bed Regeneration Transmissometer Lens Purging
Instrumentation
Glove Box Pressurizing
Instrument
Incubator Air Circulation
Weather Measurement Sampling

Manufacturing
Blower
Natural Gas Combustion Air Boost
Natural Gas Minispiral
Furnace Natural Gas Boost
Natural Gas Boost Air & Gas Sampling Oil Demisting
Gas

Combustion
Chamber
Blower
Combustion Air Boost

Application 5: Electronic Cooling


Instrumentation
Engine/Motor Cooling
Film Development System Cooling
Lamp Bank Cooling
Small Enclosure Cooling
Electronics Electronics

Blower Blower

Pressurized Cabinet Vacuum Pull-Through Cabinet

Application 6: Gas, Vapor, & Fume Recovery, Venting, & Treatment


Agricultural Pharmaceutical
Methane Gas Recovery Sterilization Gas (ETO) Recovery
Chemical Processing
Vent Header Off-Gassing Refineries
Blower Centrifuge Venting
Treatment System Environmental
Gasoline Vapor Recovery Water Pollution Control
Blower Lagoon Gas Recovery Digester Gas Collection
Scrubber Chemical Landfill Gas Recovery
Tank Radon Gas Collection
Soil Vapor Extraction &
Vent Header Off-Gassing Soil Vapor Extraction
Landfill Gas Recovery
Foundry
Lost Foam Off-Gassing

Manufacturing - Plant Services


Cabinet Fume Venting
Environmental Test Chamber Venting
Blower
Filter Blower Flame Laser Smoke Removal
Digester Weld Smoke Removal
Fume & Smoke Removal Digester Gas Collection

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 A2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Nine Major Blower Application Areas

Application 7: Solid Material Transporting, Separation, & Collection


Bin Foundry
Sand Reclamation
Tube
Carrier
Cyclone
Manufacturing - Waste Control
Chip, Dust, & Particle Removal
Liquid & Solvent Removal
Ejector Rotary Paper, Plastic Film, & Textile (Trim) Removal
Pressure Airlock
Blower
Discharge Material Handling
To Process Blower
Air Slides
Dilute Phase Pneumatic Conveying Pneumatic Tube Blast Cleaning
Dilute Phase Conveying
Pneumatic Tube

Packaging
Bag Filling

Blower Blower Collection


Chamber
Paper, Plastic, Film, & Textile (Trim) Removal General Material Separation & Collection

Application 8: Parts Blow-Off & Drying

Air Knife
Aqueous Precision Cleaning Manufacturing
Hoist
Automotive Parts Drying Conveyor Belt Blow-Off
Air Knife Semiconductor Board Drying Electroplating Fume Guiding
Electroplating Parts Drying
Blower Food Processing Electroplating Solution Blow-Back
Batter Blow-Off Flat or Irregular Metal Parts Drying
Bottle & Can Drying Wire Drying
Label Drying
Salt, Spice, & Flour Blow-Off
Blower Plating Tank
Blower
General Parts Blow-Off & Drying Solution Blow-Back

Application 9: Solution & Media Agitation & Aeration


Aquaculture
Aquarium Fish Farm, Hatchery, & Pond Aeration
Blower Blower Ground Level
Soil
Spargers
Groundwater Sparging
Water Table
Manufacturing
Wastewater Treatment Tank Aeration Groundwater Sparging Concrete Fluid Bed Aeration
Electroplating Tank Agitation
Blower
Material Handling
Blower Fluidized Beds
Plating Bath
Hot Tub Recreation
Electroplating Tank Aeration Commercial Spa Aeration Commercial Spa Aeration
Product
Bin Aerator Water Management
Blower Dock
(Air Pads) Boat, Dock, & Dam Face Deicing

Water
Water Pollution Control
UV Tube Agitation
Watewater Filter Backwash
Blower
Wastewater Treatment Tank Aeration
Bin Pad & Fluidized Bed Aeration Boat & Dock Deicing

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 A3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Product Dimensional Listing

Blowers Shipping Wt (LBS) Carton Length (In) Width (In) Height (In)

DR/EN
068 16/- 12 12 12
083 18/- 12 12 12
101 30/47 16 15 14
202 30/- 16 15 14
303 42/52 16 15 14
353 54/- 21 16 16
404 64/81 21 16 16
454 60/84 21 16 16
505 82/92 21 16 16
513 76/99 24 12 22
523 112/126 24 16 22
555 96/- 21 16 16
633 241/288 25 18 20
656 110/117 24 16 22
6 148/167 25 18 20
S7 206/- 25 18 20
757 131/158 25 18 20
808 285/287 34 23 26
833 269/297 44 29 37
858 280/338 34 23 26
S9 / P9 400/- 34 23 26
909 373/524 34 23 26
979 345/533 34 23 26
1233 400/- 34 23 26
14 620/737 43 28 33
S13 / P13 687/- 43 28 33
S15 / P15 909/- 43 28 43
Minispirals (SE2;12) 2/- 8 8 6
Nautilairs (NC33) 18/- 16 15 14
Spiral (SL2;4;5) 42/- 16 15 14

Note: Model weight will vary by HP and voltage. Refer to individual specification sheets to verify.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 B1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Industrial / Chemical Processing Blowers
AMETEK Dynamic Fluid Solutions’ ROTRON brand has long been a world leader in regenerative
blower technologies, bringing regenerative advantages to a new level, providing quiet,
maintenance-free, oil-free operation.

Our industrial DR (Domestic Regenerative) blowers include:

Rugged cast aluminum housing, cover, impeller, and muffler tower


Removable cast iron flanges bolted to a sheet metal manifold
TEFC motors on single-ended models, ODP motors on all double-ended models
Carbon steel shaft and zinc plated hardware
Permanently sealed motor bearings for 20,000-25,000 hours life

Our CP (Chemical Processing Regenerative) blowers include:

Chem-ToughTM surface conversion corrosion resistant treatment for aluminum castings


Teflon® lip seal in a stainless steel case standard for leakage containment to 25 cc/min or less
Chemical Duty motors with 303 stainless steel motor shafts
Stainless steel hardware throughout
Nickel plated flanges and muffler retainers

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 068
.125 HP Regenerative Blower

8.5
6.0 DIA.
216
152

99
3.9
6.71
174

0.97
25

0.29
3.71

8
94

T
OU
IN
3.02 1.00 2.3
58 1.00 O.D.
76 22
(2) PLACES

6.16 5.53
IN .35 DIA.
MM 155 9 140.5
(2) MTG. HOLES
6.41
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 162
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR068DJ9Y

Specification Units 081657


Motor Enclosure - Shaft Mtl. - TEFC - CS
Horsepower - 1/8
Voltage AC 115/230
Phase - Frequency - Single - 60 Hz
Insulation Class - B
NEMA Rated Motor Amps Amps (A) 18/1.0-0.9
Service Factor - 1.0
Max. Blower Amps Amps (A) 1.18/0.59
Locked Rotor Amps Amps (A) 8.7/4.35
NEMA Starter Size - 00/00
Lbs 16
Shipping Weight
Kg 7.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C1
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 068
.125 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant
• CE compliant - Declaration of Conformity on file
• Maximum flow: 13 SCFM
• Maximum pressure: 13.5 IWG
• Maximum vacuum: 13.5 IWG
• Standard motor: 1/8 HP, TEFC
• Cast aluminum blower housing, impeller & cover; slip-on steel flanges
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)
• Various horsepowers for application-specific needs

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Cast iron (threaded) or face flanges for application-specific needs

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves
• Switches - air flow, pressure, vacuum, or temperature
• External mufflers for additional silencing
• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 2.6 5.1 7.7 10.2 12.7 15.3 17.8 20.4 22.9 25.5 28.0 0 2.6 5.1 7.7 10.2 12.7 15.3 17.8 20.4 22.9 25.5 28.0
18 44.8 18 44.8
Legend Legend
15 Pressure: 37.3 15 Pressure: 37.3
Suction: Suction:
DR068 DR068
Inches of Water
Inches of Water

12 29.9 12 29.9
mbar

mbar
9 22.4 9 22.4

6 14.9 6 14.9

3 7.5 3 7.5

0 0 0 0
0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C2
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 083
.125 HP Regenerative Blower

8.49 6.85
200.4 215.6 174

(2 PLACES)
DR083DC9Y - 036862
7.89

31.8
1.25

113.8
4.48

0.37
9.4
35.3
1.39

T
IN

OU
3.28 1.20 2.95
.397 DIA.
83.3 30.5 10.1 74.9
7.02 (2 MTG. HOLES) 6.50
IN
MM 178.3 165.1
7.36
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 186.9
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR083DC9Y

Specification Units 081572


Motor Enclosure - Shaft Mtl. - TEFC -CS
Horsepower - 1/8
Voltage AC 115/230
Phase - Frequency - Single - 60 Hz
Insulation Class - B
NEMA Rated Motor Amps Amps (A) 1.8/1.0-0.9
Service Factor - 1.0
Max. Blower Amps Amps (A) 1.18/0.59
Locked Rotor Amps Amps (A) 8.7/4.35
NEMA Starter Size - 00/00
Lbs 18
Shipping Weight
Kg 8.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 1 phase motors are factory tested
and certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage
fluctuation. Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C3
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 083
.125 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 24 IWG


• Maximum vacuum: 23.2 IWG
• Standard motor: 1/8 HP, TEFC

• UL & CSA approved motor with permanently sealed ball bearings


• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Cast iron (threaded) or face flanges for application-specific needs

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 3.4 6.8 10.2 13.6 17.0 20.4 23.8 27.2 30.6 34.0 37.4 0 3.4 6.8 10.2 13.6 17.0 20.4 23.8 27.2 30.6 34.0 37.4
24 60 24 60
Legend Legend
20 Pressure: 50 20 Pressure: 50
Suction: Suction:
DR083 DR083
16 40 16 40
Inches of Water
Inches of Water

mbar

mbar
12 30 12 30

8 20 8 20

4 10 4 10

0 2 8 0 2 8
0 4 6 10 12 14 16 18 20 22 0 4 6 10 12 14 16 18 20 22

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C4
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 101 & CP 101
.33 HP Regenerative Blower
11.5 7.740
292 199

1.
ROTATION
DIRECTION

5.19
8.24
211

131

1.06
27

0.44
11
.41 3.12
3.7 10 79
1-11 1/2 6.5
94 2 MTG HOLES
FEMALE THREAD 165
IN BOTH PORTS 7.41
9.31
MM 188
236

NOTES
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR101Y9M DR101Y72M DR101Y86M CP101FB91MLR

Specification Units 038936 038937 038938 038225


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS
Horsepower - 0.33 0.33 0.33 0.33
Voltage AC 115/230 230/460 575 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 3.4/1.7 1.3/1.2/0.6 0.6 1.3-1.2/0.6
Service Factor - 1.35 1.25 1.25 1.25
Max. Blower Amps Amps (A) 3.4/1.7 1.30/.65 0.4 1.3/0.65
Locked Rotor Amps Amps (A) 16.4/8.2 6.4-5.8/2.9 4.2 6.4-5.8/2.9
NEMA Starter Size - 00/00 00-00/00 00 00-00/00
Lbs 30 30 30 30
Shipping Weight
Kg 13.6 13.6 13.6 13.6

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 1 phase motors are factory tested
and certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage
fluctuation. Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C5
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 101 & CP 101
.33 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum flow: 31 SCFM


• Maximum pressure: 32 IWG
• Maximum vacuum: 28.5 IWG
• Standard motor: 0.33 HP, TEFC

• UL & CSA approved motor with permanently sealed ball bearings


• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 5 10 15 20 25 31 36 41 46 51 56 0 5 10 15 20 25 31 36 41 46 51 56
60 15 60 15

50 Legend 125 50 Legend 125


Pressure: Pressure:
40 Suction: 100 40 Suction: 100
Inches of Water
Inches of Water

DR101 DR101
mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0 0
0 3 6 9 12 15 18 21 24 27 30 33 0 3 6 9 12 15 18 21 24 27 30 33

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C6
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 202 & CP 202
.33 HP Regenerative Blower

11.78
9.63
299
245
STANDARD
.88 ROTATION
22

114
4.5
2.83
72
10.00

5.18
131
254

1.53

5.03
39

127
0.44
2.52 3.27 .398 DIA. (4X) 3.94
10 100
64 83
8.12 1 1/4-11 1/2 NPSC
206.2 STRAIGHT THREAD
11.30 (2X) CAST IRON FLANGES
286 8.91
226.3
IN
MM

NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR202Y9M DR202Y72M DR202Y86M CP202AE72MLR CP202FA91MLR

Specification Units 080564 080565 080566 038953 038227


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS
Horsepower - .33 0.33 0.33 0.33 0.33
Voltage AC 115/230 230/460 575 230/460 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 3.4/1.7 1.2/0.6 0.5 1.2/0.6 1.2/0.6
Service Factor - 1.35 1.35 1.35 1.35 1.35
Max. Blower Amps Amps (A) 5.2/2.6 1.54/0.77 0.57 1.54/0.77 1.54/0.77
Locked Rotor Amps Amps (A) 16.4/8.2 6.4/3.2 2.6 6.4/3.2 6.4/3.2
NEMA Starter Size - 00/00 00/00 00 00/00 00/00
Lbs 30 30 30 30 30
Shipping Weight
Kg 13.6 13.6 13.6 13.6 13.6

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C7
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 202 & CP 202
.33 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 40 IWG


• Maximum vacuum: 35 IWG
• Standard motor: 0.33 HP, TEFC

• UL & CSA approved motor with permanently sealed ball bearings


• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models
• Cast iron (threaded) or face flanges for application-specific needs

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
DR202 DR202
40 100 40 100
Inches of Water
Inches of Water

mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 0 5 10 15 20 25 30 35 40 45 50 55

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C8
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 303 & CP 303
0.5 HP Regenerative Blower
L 9.61
2 ROTATION DIRECTION
244.6

114.3
4.5

2.83
72
132.1
10.0
254

5.19

127
5.0

11.2
0.44
1.44
36.6
2.45 3.27 3.94
.398 DIA.
64 83.1 10.1 100.1
IN (4) MTG. HOLES
11.3 8.13
MM
287 206.5

NOTES 1 1/4 - 11 1/2 NPSC 8.91


1 TERMINAL BOX CONNECTOR HOLE .88 (22.4) DIA. FEMALE THREAD 226.3 MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. BOTH PORTS DR303AE9M 11.86/301.2
DR303AE72M 11.6/294.6
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR303AE86M 11.93/303

Part/ Model Number

DR303AE9M DR303AE72M DR303AE86M CP303FA91MLR

Specification Units 038841 038842 038843 080148


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS
Horsepower - 0.5 0.5 0.5 0.5
Voltage AC 115/230 230/460 575 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 6.2/3.1 1.3-1.2/0.6 0.6 1.3-1.2/0.6
Service Factor - 1.25 1.25 1.25 1.25
Max. Blower Amps Amps (A) 6/3 1.63/0.83 0.7 1.63/0.83
Locked Rotor Amps Amps (A) 21/10.5 10-9.2/4.6 4.2 10-9.2/4.6
NEMA Starter Size - 00/00 00/00 00 00/00
Lbs 34 42 42 42
Shipping Weight
Kg 15.4 19.1 19.1 19.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C9
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 303 & CP 303
0.5 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 48 IWG


• Maximum vacuum: 45 IWG
• Standard motor: 0.5 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
DR303 DR303
Inches of Water
Inches of Water

40 100 40 100
mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 0 5 10 15 20 25 30 35 40 45 50 55

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 10
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 353 & CP 353
.75 HP Regenerative Blower

L 11.5
292
5.55
141
ROTATION DIRECTION
1

5.13
130
3.56
90
12.22
311

1.75
6.22
Ø6.13

44
158
156

0.41
OUT

10
IN
.47 DIA.
12
(4) MTG HOLES 5.12
3.15 3.75 130
79 95
IN 8.93
12.75 226.8
MM
324
10.18
NOTES 1 1/2 - 11 1/2 NPSC THREAD
BOTH PORTS 258 MODEL L (IN/MM)
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR353BR9M 13.97/355
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR353BR72M 12.5/317

Part/ Model Number

DR353BR9M DR353BR72M DR353BR86M CP353BR72MLR CP353FD72MLR

Specification Units 080554 080555 080556 081562 081612


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS
Horsepower - 0.75 0.75 0.75 0.75 0.75
Voltage AC 115/230 230/460 575 230/460 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three 60 Hz Three 60 Hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 10.0/5.0 3.0/1.5 0.96 3.0/1.5 3.0/1.5
Service Factor - 1.15 1.25 1.25 1.25 1.25
Max. Blower Amps Amps (A) 12/6 3.5/1.75 1.0 3.5/1.75 3.5/1.75
Locked Rotor Amps Amps (A) 59.6/29.8 15.2/7.6 6.1 15.2/7.6 15.2/7.6
NEMA Starter Size - 00/00 00/00 00 00/00 00/00
Lbs 60 54 54 54 54
Shipping Weight
Kg 27.2 24.5 24.5 24.5 24.5

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 11
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 353 & CP 353
.75 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 50 IWG


• Maximum vacuum: 45 IWG
• Standard motor: 3/4 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
DR353 DR353
40 100 40 100
Inches of Water
Inches of Water

mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 12
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 404 & CP 404
1.0 HP Regenerative Blower
L 11.5
1
292.1

5.04

4.12
12.18
309.4

182.4
7.18

6.28
160

0.41
8.9
42.4
1.67
3.05 3.75 5.12
.47 DIA.
79.2 95.3 11.9 130
(4) MTG. HOLES 8.93
12.63
IN 320.8 226.8
MM
10.3
1 1/2 - 11 1/2 NPSC
NOTES FEMALE THREAD 261.6
1 TERMINAL BOX CONNECTOR HOLE .88 (22.4) DIA. KNOCK-OUT BOTH PORTS MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR404AL58M 14.41/366.0
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR404AL72M 14.18/360.2
DR404AL86M 13.38/339.9

Part/ Model Number

DR404AL58M DR404AL72M DR404AL86M CP404CU72MLR

Specification Units 037407 037406 037408 038233


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS
Horsepower - 1.0 1.0 1.0 1.0
Voltage AC 115/230 230/460 575 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 11.4/5.7 3.0/1.5 1.2 3.0/1.5
Service Factor - 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 14.5/7.25 4.0/2.0 1.4 4.0/2.0
Locked Rotor Amps Amps (A) 70/35 21.0/10.5 7.6 21.0/10.5
NEMA Starter Size - 00/00 00/00 00 00/00
Lbs 69 64 64 64
Shipping Weight
Kg 31.3 29 29 29

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 13
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 404 & CP 404
1.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 58 IWG


• Maximum vacuum: 50 IWG
• Standard motor: 1.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
60 150 60 150

Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
DR404 100 DR404 100
40 40
Inches of Water
Inches of Water

75 75
mbar

mbar
30 30

20 50 20 50

10 25 10 25

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 14
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 454 & CP 454
1.5 HP Regenerative Blower
L

4.31 12.5
1 ROTATION DIRECTION
110 318

120.7
4.75

5.24
133
4.36
111
13.5
343

4.18
106
IN OUT

175
6.9

0.42
11
2.0
51
3.25 4.75
1.78 120
83 45 .59 DIA.
15 10.30
4.5 (6) MTG HOLES
114.3 261.6
IN
MM 12.56 11.4
1 1/2 - 11 1/2 NPSC
319 FEMALE THREAD 290
NOTES BOTH PORTS
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR454R58M 14.47/367
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR454R72M 13.31/338

Part/ Model Number

DR454R58M DR454R72M DR454R86M CP454EZ72MLR

Specification Units 080481 080480 080482 080491


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS
Horsepower - 1.5 1.5 1.5 1.5
Voltage AC 115/230 230/460 575 230/460
Phase - Frequency - Single - 50/60 Hz Three - 50/60 Hz Three - 50/60 Hz Three - 50/60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 15.6/7.8 4.6/2.3 1.8 4.6/2.3
Service Factor - 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 18/9 5.2/2.6 2.1 5.2/2.6
Locked Rotor Amps Amps (A) 84/42 32/16 12.8 32/16
NEMA Starter Size - 1/0 00/00 00 00/00
Lbs 73 60 60 60
Shipping Weight
Kg 33.1 27.2 27.2 27.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 15
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 454 & CP 454
1.5 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 65 IWG


• Maximum vacuum: 60 IWG
• Standard motor: 1.5 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 25 51 76 102 127 153 178 204 229 255 280 0 25 51 76 102 127 153 178 204 229 255 280
90 224 90
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
DR454 149 DR454 149
60 60
Inches of Water
Inches of Water

112 112
mbar

mbar
45 45

30 75 30 75

15 37 15 37

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 16
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 505 & CP 505
2.0 / 3.0 HP Regenerative Blower
L 13.59 DIA.
1 345.2

ROTATION DIRECTION

IA.
8D
7.1 182.4

B
366.5
14.43

.37 REF.
184.2

48.5

9.4
1.91
7.25
IN OUT

3.56 4.5 4.75


.59 DIA.
90.4 114.3 120.7
15
14.18 (4) MTG HOLES 10.30
360.2 261.6
IN
MM 1 1/2 - 11 1/2 NPSC 11.70 REF. MODEL L (IN/MM) B (IN/MM) C (IN/MM)
FEMALE THREAD 297.2 DR505AS58M 15.63/397 4.63/117 5.64/143
BOTH PORTS DR505AS72M 14.75/374 4.25/108 5.25/133
NOTES DR505AS86M 14.38/365 4.37/111 5.18/131
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA.
DR505K58M 17.0/431 4.63/117 5.64/143
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR505K72M 15.63/397 4.37/111 5.18/131

Part/ Model Number

DR505AS58M DR505AS72M DR505AS86M DR505K58M DR505K72M CP505FE72MLR CP505CT72MLR

Specification Units 037542 037543 037544 081882 037551 038239 038237


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS CHEM TEFC - SS
Horsepower - 2.0 2.0 2.0 3.0 3.0 3.0 2.0
Voltage AC 115/230 230/460 575 115/230 230/460 230/460 230/460
Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F F F F
NEMA Rated Motor Amps Amps (A) 18.2/9.1 5.4/2.7 2.3 25.6/12.8 7.6/3.8 7.6/3.8 5.4/2.7
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 24/11.5 7/3.5 3.0 28/14 8.8/4.4 8.8/4.4 6.8/3.4
Locked Rotor Amps Amps (A) 138/69 38/19 21 194/97 88/44 88/44 38/19
NEMA Starter Size - 1/0 00/00 00 1.5/0 0/0 0/0 00/00
Lbs 97 82 84 91 86 86 82
Shipping Weight
Kg 44 37.2 38.1 41.3 39 39 37.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 17
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 505 & CP 505
2.0 / 3.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 88 IWG


• Maximum vacuum: 73 IWG
• Standard motor: 2.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 25 51 76 102 127 153 178 204 229 255 280 0 25 51 76 102 127 153 178 204 229 255 280
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
DR505K72M 149 DR505K72M 149
60 60
Inches of Water

DR505AS72M DR505AS72M
Inches of Water

DR505K58M DR505K58M
mbar

mbar
45 DR505AS58M 112 45 DR505AS58M 112

30 75 30 75

15 37 15 37

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 18
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 513 & CP 513
1.5 HP Regenerative Blower

13.88 14.21
1
352.6 360

ROTATION

5.07

4.13
129

106
7.18
182
16.06
408

224
IN OUT

8.8

0.5
13
2.4
61
3.72 5.50 4.8
IN .59 DIA.
93 139.7 15 122
MM
13.69 (4) MTG HOLES 11.4
346 289.6
NOTES
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. 1 1/2 - 11 1/2 NPSC 12.8
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. FEMALE THREAD 325
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. BOTH PORTS

Part/ Model Number

DR513R72 DR513R58 DR513R86 CP513EZ72LR

Specification Units 037217 037209 037773 038241


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS
Horsepower - 1.5 1.5 1.5 1.5
Voltage AC 230/460 115/230 575 230/460
Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 4.6/2.3 16.8/8.4 1.8 4.6/2.3
Service Factor - 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 5/2.5 19/9.5 1.85 5/2.5
Locked Rotor Amps Amps (A) 43/21 120/60 13 43/21
NEMA Starter Size - 00/00 1/0 00 00/00
Lbs 76 95 76 76
Shipping Weight
Kg 34.5 43.1 34.5 34.5

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 19
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 513 & CP 513
1.5 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 88 IWG


• Maximum vacuum: 80 IWG
• Standard motor: 1.5 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
DR513 DR513
60 149 60 149
Inches of Water
Inches of Water

mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 20
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 523 & CP 523
3.0HP High Pressure Regenerative Blower

L SEE NOTE 1
14.21
13.63 358.1
346.2

ROTATION DIRECTION

5.23
133
4.19

4.25
108

108
16.12
409.5

6.95

220.7
8.69
IN OUT

0.5
13
56.4
2.22
4.75
120.6
4.7 5.50
.59 DIA. 11.42
119.4 139.7 15.0 1 1/2 - 11 1/2 NPSC 290.1
14.16 (4) MTG. HOLES FEMALE THREAD 12.8
BOTH PORTS
359.7 325.1
IN
MM 14.4
365.8

NOTES
1 TERMINAL BOX CONNECTOR HOLE .88 (22.4) DIA. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR523K72 15.91/404.1
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR523K58 19.31/490.5

Part/ Model Number

DR523K72 DR523K58 DR523K86 CP523CS72LR

Specification Units 037210 037211 037772 038243


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-SS
Horsepower - 3 3 3 3
Voltage AC 230/460 115/230 575 230/460
Phase - Frequency - Three-60 hz Single-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 8.8-8,6/4.3 27/13.5 3.4 8.8-8.6/4.3
Service Factor - 1.15 1.0 1.0 1.15
Max. Blower Amps Amps (A) 8.9/4.45 30/15 3.4 8.9/4.45
Locked Rotor Amps Amps (A) 91.3/45.7 196/98 36.4 91.3/45.7
NEMA Starter Size - 0/0 1.5/1 0 0/0
Lbs 112 145 112 112
Shipping Weight
Kg 50.8 65.8 50.8 50.8

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 21
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 523 & CP 523
3.0HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 158 IWG


• Maximum vacuum: 135 IWG
• Standard motor: 3.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
180 450 180 450
Legend Legend
150 Pressure: 375 150 Pressure: 375
Suction: Suction:
DR523 DR523
120 300 120 300
Inches of Water
Inches of Water

mbar

mbar
90 225 90 225

60 150 60 150

30 75 30 75

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 22
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 555 & CP 555
3.0 / 4.0 HP Regenerative Blower
L 14.93
15.06

MODEL L (IN/MM)
NOTES
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. DR555CK72 17.44/443
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR555K72 16.12/409
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR555K58 17.38/441

Part/ Model Number

DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72MLR

Specification Units 081100 081102 081099 081098 081101 038245


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS
Horsepower - 4.0 4.0 3.0 3.0 3.0 3.0
Voltage AC 230/460 575 230/460 115/230 575 230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 10/5 4.1 7.6/3.8 25.6/12.8 3 7.6/3.8
Service Factor - 1.15 1.15 1.15 1.0 1.0 1.15
Max. Blower Amps Amps (A) 13/6.5 4.2 8.8/4.4 28/14 3.4 8.8/4.4
Locked Rotor Amps Amps (A) 94/47 80 88/44 194/97 70 88/44
NEMA Starter Size - 1/0 0 0/0 1.5/1 0 0/0
Lbs 113 137 96 91 90 90
Shipping Weight
Kg 51.3 62.1 43.5 41.3 40.8 40.8

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 23
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 555 & CP 555
3.0 / 4.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 115 IWG


• Maximum vacuum: 92 IWG
• Standard motor: 4.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DR555CK72 DR555CK72
80 200 80 200
Inches of Water

DR555K72 DR555K72
Inches of Water

DR555K58 DR555K58
mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 24
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 6 & CP 6
3.0 / 5.0 HP Regenerative Blower

4.86 L
MUFFLER
123.4
4 4.0
.95 3.3 8
.
84 101.6
24.1
2 - 11 1/2 NPSC
FEMALE THREAD
BOTH PORTS

ROTATION DIRECTION

141.7
OU IN

5.58
T

215.9
8.50
419
16.5

16.34
415

215.9
8.50
1

102
4.0
6.98 7.0 2.00 3.20
177 178 50.8 101.6
IN
MM 14.63 8.00
.562 DIA.
(4) MTG. HOLES 203.2
NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.06 (26.9) DIA. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR6D89 18.00/457.2
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.
DR6K72 18.00/457.2

Part/ Model Number

DR6D89 DR6D5 DR6D86 DR6K72 CP6FF72LR HiE6D89

Specification Units 027578 036212 027579 027600 038253 038071


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 5.0 5.0 5.0 3.0 5.0 5.0
Voltage AC 230/460 230 575 230/460 230/460 230/460
Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 11.2/5.5 21 4.8 13.3-12/6 17.3-15.6/7.8 17.3-15.6/7.8
Service Factor - 1.15 1.0 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 16/8 25 5.4 12/6 15-14.8/7.4 15-14.8/7.4
Locked Rotor Amps Amps (A) 165-155/76 124 60 106/53 165-155/76 165-155/76
NEMA Starter Size - 1/1 1.5 1 1/0 1/1 1/1
Lbs 148 156 148 132 148 148
Shipping Weight
Kg 67.1 70.8 67.1 59.9 67.1 67.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 25
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 6 & CP 6
3.0 / 5.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 110 IWG


• Maximum vacuum: 91.2 IWG
• Standard motor: 5.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• 52248 1 pc.

MOTOR OPTIONS
• International voltage & frequency (Hz)

designs

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package
Blower Performance at Standard Conditions
60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DR6D89 DR6D89
80 200 80 200
Inches of Water

DR6K72 DR6K72
Inches of Water

DR6D5 DR6D5
mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 26
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 633 & CP 633
5.0 / 7.5 HP High Pressure Regenerative Blower
4.88 13.16
124.0 334.3 16.68
1.03
26.2 423.7

DIRECTION
OF
ROTATION
18.94
481.1

10.50
266.7

10.59
269.0
3.22
81.8
IN OUT

.5.1
.20
6.22
.98 (2X) 158.0
6.10
24.9 154.9 2" NPSC
11.811 2.66 17.244
IN 438.0 FEMALE THREAD
300.0 67.6 18.41 BOTH PORTS
MM 18.06
467.6
458.7
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. INCLUDES INLET FILTER
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR633AY72M DR633AY86M DR633D89M CP633FG72LRM

Specification Units 081691 081693 081689 081695


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS
Horsepower - 7.5 7.5 5 7.5
Voltage AC 230/460 575 208-230/460 230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F
NEMA Rated Motor Amps Amps (A) 23-21/10.5 8.4 16.9-15.3/76 23-21/10.5
Service Factor - 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 19.8-18/9 7.9 15-13.6/6.8 19.8-18/9
Locked Rotor Amps Amps (A) 170/85 55 165-155/76 170/85
NEMA Starter Size - 2/1 1 1-1/0 2/1
Lbs 241 241 223 241
Shipping Weight
Kg 109.3 109.3 101.2 109.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 27
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 633 & CP 633
5.0 / 7.5 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant


• Maximum pressure: 275 IWG
• Maximum vacuum: 190 IWG
• Standard motor: 7.5 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 25 51 76 102 127 153 178 204 229 255 280 0 25 51 76 102 127 153 178 204 229 255 280
300 750 300 750
Legend Legend
250 Pressure: 625 250 Pressure: 625
Suction: Suction:
DR633AY72M DR633AY72M
200 500 200 500
Inches of Water

DR633D89M DR633D89M
Inches of Water

mbar

mbar
150 375 150 375

100 250 100 250

50 125 50 125

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 28
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 656 & CP 656
3.0 / 3.5 HP Regenerative Blower
15.42
L
390.5

STD. DIRECTION
OF ROTATION
1
Ø7.19
182.6

5.56
141
4.56
116
15.17
382.5

7.46
190
2" NPSC
STRAIGHT THDS
0.59 4.92 BOTH PORTS

17.3
0.64
57.2
2.25
4.14 5.51 15 125
(4X) MTG
105.2 140 HOLES 11.420
289.6
15.12 12.81
IN 384 325.4
MM

NOTES
MODEL L (IN/MM)
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR656CK72X 17.50/444.5
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR656K72X 16.00/406.4

Part/ Model Number

DR656CK72X DR656CK86X DR656CK5X DR656K72X DR656K58X CP656CR72XLR

Specification Units 080582 080583 080584 080602 080603 080065


Motor Enclosure - Shaft Mtl. - TEFC - CS TEFC - CS TEFC-CS TEFC - CS TEFC - CS CHEM TEFC-SS
Horsepower - 3.5 3.5 3.5 3.0 3.0 3.5
Voltage AC 230/460 575 230 230/460 115/230 230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 10.0/5.0 4.0 18 7.4/3.7 29/14.5 10.0/5.0
Service Factor - 1.15 1.0 1.15 1.15 1.0 1.15
Max. Blower Amps Amps (A) 11.4/5.7 5.2 18 9/4.5 27.8/13.9 11.4/5.7
Locked Rotor Amps Amps (A) 94/47 80 115 54/27 172/86 94/47
NEMA Starter Size - 1/0 0 1 0/0 1.5/1.0 1/0
Lbs 110 114 101 103 114 110
Shipping Weight
Kg 49.9 51.7 45.8 46.7 51.7 49.9

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperaturs - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for
Class F rated motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient
temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 29
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 656 & CP 656
3.0 / 3.5 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant


• Maximum pressure: 110 IWG
• Maximum vacuum: 89 IWG
• Standard motor: 4.0 HP, TEFC

• UL & CSA approved motor with permanently sealed ball bearings



• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

• Cast iron cover for additional noise resonance

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
80 200 80 200
Inches of Water

DR656K58X DR656K58X
Inches of Water

DR656K72X DR656K72X
mbar

mbar
60 DR656CK72X 150 60 DR656CK72X 150
DR656CK5X DR656CK5X
40 100 40 100

20 50 20 50

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 30
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 757 & CP 757
4.0 / 5.0 HP Regenerative Blower
16.75
L 426
ROTATION
DIRECTION

5.04
128
17.44
443

6.57
167
2 1/2" NPSC

9.23
234
FEMALE THREADS
BOTH PORTS

5.75

2.77
70
15.3 146

21
.84
389 10.31
5.60 2.81 262
0.63 142.2 12.73
71 323.3 16.3
16 2.0
50 414

7.02
178
MODEL L (IN/MM)
2.0
50

IN
5.71
145

MM R0.31 DR757CK72X 18.55/471


7.9
DR757CK86X 18.55/471
NOTES CL OF BLOWER
DR757D89X 18.55/471
1 TERMINAL BOX CONNECTOR HOLE 1.06 (26) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR757D86X 18.55/471
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR757D5MX 18.55/471

Part/ Model Number

DR757CK72X DR757CK86X DR757D89X CP757FF72XLR CP757CR72XLR

Specification Units 081172 081173 081169 081178 081179


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS CHEM TEFC-SS
Horsepower - 4.0 4.0 5.0 5.0 4.0
Voltage AC 230/460 575 230/460 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three - 60 hz Three - 60 hz Three-60 hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 10/5 4.0 12/6 12/6 10/5
Service Factor - 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 12/6 4.2 15.5/7.6 15.5/7.6 12/6
Locked Rotor Amps Amps (A) 94/47 80 194/97 194/97 94/47
NEMA Starter Size - 1/0 0 1/0 1/0 1/0
Lbs 131 128 140 140 131
Shipping Weight
Kg 59.4 58.1 63.5 63.5 59.4

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 31
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 757 & CP 757
4.0 / 5.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant


• Maximum pressure: 83 IWG
• Maximum vacuum: 75 IWG
• Standard motor: 4.0 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 51 102 153 204 255 306 357 408 459 510 561 0 51 102 153 204 255 306 357 408 459 510 561
90 224 90 224

Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
60 DR757D89X 149 60 DR757D89X 149
Inches of Water
Inches of Water

DR757CK72X DR757CK72X
mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °0C


Temp Rise °C

50 50

0 0

100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 32
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S7
7.5 HP High Pressure Regenerative Blower
2 - 11 1/2 NPT
FEMALE THREAD
BOTH PORTS
16.38
416.1
6.44
163.6
5.88
149.4
3.22
23.03 81.8
585 2 - 11 1/2 NPT
A FEMALE THREAD
BOTH PORTS

147.8
IN

5.58
OU
T
16.44
417.6

209.6
8.25

101.6
4.00
NOTE 1

A 4.94
IN 125.5
MM 8.03 7.00 2.00 8.00
.563 DIA.
NOTES 204 177.8 50.8 14.3 203.2
1 TERMINAL BOX CONNECTOR HOLE 1.06 (26.9) DIA. (4) MTG. HOLES 11.50
11.00
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 292.1
279.4
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. SECTION VIEW A-A

Part/ Model Number

DRS7X72 DRS7X86

Specification Units 036085 036144


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS
Horsepower - 7.5 7.5
Voltage AC 230/460 575
Phase - Frequency - Three-60 Hz Three-60 Hz
Insulation Class - F F
NEMA Rated Motor Amps Amps (A) 19.4/9.7 7.8
Service Factor - 1.15 1.0
Max. Blower Amps Amps (A) 24/12 9.6
Locked Rotor Amps Amps (A) 166/83 66
NEMA Starter Size - 1/1 1
Lbs 206 206
Shipping Weight
Kg 93.4 93.4

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 33
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S7
7.5 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 140 IWG


• Maximum vacuum: 112 IWG
• Standard motor: 7.5 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
175 436 175 436
Legend Legend
150 Pressure: 373 150 Pressure: 373
Suction: Suction:
DRS7 DRS7
125 311 125 311
Inches of Water
Inches of Water

mbar

mbar
100 249 100 249

50 124 50 124

25 62 25 62

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 34
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 808 & CP 808
5.0 / 7.5 HP Regenerative Blower
L
18.73
475.7

536.4
21.12

11.75
298
1 IN OUT

91.2
3.59
3.5

22.9
0.9
8.75 7.38
187.5 .562 DIA. 88.9
222 8.5 14.3 7.0
216 (8) MTG. HOLES
22.38 177.8
568.5 1.91 14.76
48.5 374.9
15.75
IN 400.1
MM
2 1/2 - 8 NPSC 17.43
FEMALE THREAD 442.7
NOTES BOTH PORTS
MODEL L (IN/MM)
1 TERMINAL BOX CONNECTOR HOLE 1.06 (26.9) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR808AY72MX 22.23/564.6
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR808D89MX 19.31/490.5

Part/ Model Number

DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX

Specification Units 081222 081224 081225 081233 081228


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 7.5 7.5 5.0 7.5 7.5
Voltage AC 230/460 575 230/460 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 17.8/8.9 7.2 17.3-15.6/7.8 17.8/8.9 17.8/8.9
Service Factor - 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 28/14 10.8 14/7 28/14 28/14
Locked Rotor Amps Amps (A) 120/60 60 152/76 120/60 120/60
NEMA Starter Size - 1/1 1 1/0 1/1 1/1
Lbs 285 242 195 285 301
Shipping Weight
Kg 129.3 109.8 88.5 129.3 136.5

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 35
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 808 & CP 808
5.0 / 7.5 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant


• Maximum pressure: 120 IWG
• Maximum vacuum: 95 IWG
• Standard motor: 7.5 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DR808AY72MX DR808AY72MX
80 200 80 200
Inches of Water

DR808D89MX DR808D89MX
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 36
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 833 & CP 833
7.5 / 10.0 HP Regenerative Blower
5.24 13.98
.84 133.1 355.1 19.13
21.3 485.9
DIRECTION
OF
ROTATION
19.38
492.3

ROTATION
10.50 DIA
266.7

10.44
265.2
81.8
3.22
IN OUT

5.1
.20
6.22
.98 (2X) 158.0 6.10
24.9 11.811 8.71 17.638 154.9 2" - 11 1/2 NPSC
448.01 18.81 FEMALE THREAD
300.0 221.2 BOTH PORTS
24.0 477.8
609.6

IN .512 MTG. HOLE


MM 13.0 DETAIL
.591
15.0

(4X)
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. FILTER 515255 INCLUDED

Part/ Model Number

DR833BB72M DR833BB86M DR833AY72M DR833AY86M CP833FH72MLR

Specification Units 081702 081704 081699 081701 081710


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS
Horsepower - 10 10 7.5 7.5 10
Voltage AC 230/460 575 230/460 575 230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 31-28/14 9.6 23-21/10.5 8.4 31-28/14
Service Factor - 1.15 1.15 1.15 1.15 1.15
Max Blower Amps Amps (A) 26-24/12 8.9 21.2-19.2/9.6 7.7 26-24/12
Locked Rotor Amps Amps (A) 190/95 73 170/85 68 190/95
NEMA Starter Size - 2/1 1 2/1 1 2/1
Lbs 269 269 260 260 269
Shipping Weight
Kg 122 122 117.9 117.9 122

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 37
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 833 & CP 833
7.5 / 10.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant


• Maximum pressure: 258 IWG
• Maximum vacuum: 174 IWG
• Standard motor: 10 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
300 750 300 750
Legend Legend
250 Pressure: 625 250 Pressure: 625
Suction: Suction:
DR833BB72M DR833BB72M
200 500 200 500
Inches of Water

DR833AY72M DR833AY72M
Inches of Water

mbar

mbar
150 375 150 375

100 250 100 250

50 125 50 125

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 38
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 858 & CP 858
7.5 / 10.0 HP Regenerative Blower
L 18.60
472.4
22.34 7.09
567.4
180.3
6.81 13.53 2.00 3.55
1.19 2 1/2 - 8 NPSC
175.3 343.7 50.8 90.2 FEMALE THREAD
BOTH PORTS
4.00
101.6

ROTATION DIRECTION

11.68
296.7
OUT IN

211.1
8.31
21.81
553.9

10.18
259.1

10.13
257.3
NOTE 1

1.75
10.00 9.50 44.5 6.4 1.97
IN 256.3 241.3 162.6 50
MM
13.00 .75 X 2.00 SLOT 8.49
330.2 19.05 X 50.8 215.6
NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.06 (26.9) DIA. (4) PLACES 9.99
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. MODEL L (IN/MM)
252.5 DR858AY72W 23.06/585.7
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR858BB72W 23.19/589

Part/ Model Number

DR858BB72W DR858BB86W DR858AY72W CP858FH72WLR HiE858BB72W

Specification Units 038740 038742 038738 038749 038743


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 10 10 7.5 10 10
Voltage AC 230/460 575 230/460 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 26/13 10.5 17.8/8.9 26/13 26/13
Service Factor - 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 28/14 12 28/14 28/14 28/14
Locked Rotor Amps Amps (A) 162/81 65 120/60 162/81 162/81
NEMA Starter Size - 2/1 1 1/1 2/1 2/1
Lbs 280 280 264 280 280
Shipping Weight
Kg 127 127 119.7 127 127
Model (Base Mount) - DR858BB72X DR858BB86X DR858AY72X
Part Number (Base Mount) - 038735 038737 038736

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 39
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 858 & CP 858
7.5 / 10.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 125 IWG


• Maximum vacuum: 104.8 IWG
• Standard motor: 10 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
150 373 150 373
Legend Legend
125 Pressure: 311 125 Pressure: 311
Suction: Suction:
DR858AY72W DR858AY72W
100 249 100 249
Inches of Water

DR858BB72W DR858BB72W
Inches of Water

mbar

mbar
75 187. 75 187.

50 124 50 124

25 62 25 62

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 40
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P9
15.0 / 20.0 HP Regenerative Blower

7.09
180.1
3.55
L 90.2
4.00 DIA. SLIP-ON
2
101.6 A

ROTATION DIRECTION

207.3
8.16
21.81 REF.
18.00 DIA.

554
457.2

10.00
254
2 1/2 - 8 NPSC A
FEMALE THREAD 7.56
BOTH PORTS 10.88 9.25 192
1
276.4 234.9
10.00
12.00 .56 DIA. 254
304.8 14.2
IN (4) PLACES SECTION VIEW A-A
MM

NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.37 (34.8) DIA.
2 PRESSURE OUTLET CONNECTION. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DRP9BM72C 31.75/806.5
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DRP9BL72C 33.44/849.4

Part/ Model Number

DRP9BM72C DRP9BM72D DRP9BM86C DRP9BM86D DRP9BL72C DRP9BL72D

Specification Units 037033 036275 037040 036276 036512 036513


Motor Enclosure - Shaft Mtl. - ODP-CS ODP - CS ODP-CS ODP - CS ODP-CS ODP - CS
Horsepower - 20 20 20 20 15 15
Voltage AC 230/460 230/460 575 575 230/460 230/460
Phase - Frequency - Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 49/24.5 49/24.5 20 20 37/18.5 37/18.5
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 60/30 60/30 22.2 22.2 50/25 50/25
Locked Rotor Amps Amps (A) 306/153 306/153 115 115 256/128 256/128
NEMA Starter Size - 3/2 3/2 2 2 2/2 2/2
Lbs 400 408 464 408 380 418
Shipping Weight
Kg 181.4 185.1 210.5 185.1 172.4 189.6
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 41
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P9
15.0 / 20.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 116 IWG


• Maximum vacuum: 95 IWG
• Standard motor: 20 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings


part #515185

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 136 272 408 544 680 816 951 1087 1223 1359 1495 0 136 272 408 544 680 816 951 1087 1223 1359 1495
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DRP9BM72C DRP9BM72C
80 200 80 200
Inches of Water

DRP9BL72C DRP9BL72C
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 80 160 240 320 400 480 560 640 720 800 880 0 80 160 240 320 400 480 560 640 720 800 880

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 42
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S9
15.0 / 20.0 HP High Pressure Regenerative Blower

457.2
18.0
7.09
180.1
2 1/2 - 8 NPSC
FEMALE THREAD 3.55
BOTH PORTS 90.2
L
A

ROTATION DIRECTION

207.3
8.16
21.81
554
XXXXXXX XXXXXXX XXXXXXX

254
10.0
NOTE 1

A
IN 5.00
MM 10.50 9.25 7.56 127
223 234.9 190.5
12.00 10.00
NOTES 254 MODEL L (IN/MM)
.60 X 1.35 SLOT(4) (DRS9BM72)
1 TERMINAL BOX CONNECTOR HOLE 1.37 (34.8) DIA. 304.8 .56 (14.2) DIA. (DRS9BL72) SECTION VIEW A-A DRS9BM72 31.75/806.5
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DRS9BL72 33.44/849.4

Part/ Model Number

DRS9BM72 DRS9BM86 DRS9BL72

Specification Units 037032 037041 036514


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS ODP-CS
Horsepower - 20 20 15
Voltage AC 230/460 575 230/460
Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz
Insulation Class - F F F
NEMA Rated Motor Amps Amps (A) 48/24 20 36/18
Service Factor - 1.15 1.15 1.0
Max. Blower Amps Amps (A) 56/28 20.4 56/28
Locked Rotor Amps Amps (A) 288/144 115 222/111
NEMA Starter Size - 3/2 2 2/2
Lbs 446 446 418
Shipping Weight
Kg 202.3 202.3 189.6

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 43
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S9
15.0 / 20.0 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 206 IWG


• Maximum vacuum: 157 IWG
• Standard motor: 60 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings


part #515185

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 67 136 204 272 340 408 475 544 611 680 748 0 67 136 204 272 340 408 475 544 611 680 748
210 525 210 525
Legend Legend
175 Pressure: 437 175 Pressure: 437
Suction: Suction:
DRS9BL72C 350 DRS9BL72C 350
140 140
Inches of Water

DRS9BM72C DRS9BM72C
Inches of Water

mbar

mbar
105 263 105 263

70 175 70 175

35 88 35 88

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 44
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 909 & CP 909
10.0 / 15.0 HP Regenerative Blower

IN
MM
NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.25 (31.8) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR909BE72W DR909BE86W DR909BB72W DR909BB86W CP909FJ72WLR HiE909BE72W

Specification Units 081737 081739 081738 081744 038632 081735


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 15 15 10 10 15 10
Voltage AC 208-230/460 575 230/460 575 208-230/460 208-230/460
Phase - Frequency - Three-60 hz Three-60 hz Three - 60 Hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 41.5-37.6/18.8 14.6 26/13 10.5 41.5-37.6/18.8 41.5-37.6/18.8
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 42/21 17 34/17 13.0 42/21 42/21
Locked Rotor Amps Amps (A) 318/159 164 162/81 65 318/159 318/159
NEMA Starter Size - 2/2 2 2/1 1 2/2 2/2
Lbs 400 400 400 400 400 400
Shipping Weight
Kg 181.4 181.4 181.4 181.4 181.4 181.4
Model (Base Mount) - DR909BE72X DR909BE86X DR909BB72X DR909BB86X
Part Number (Base Mount) - 038622 038626 038623 080183

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 45
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 909 & CP 909
10.0 / 15.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 137 IWG


• Maximum vacuum: 106 IWG
• Standard motor: 15 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards when properly piped and

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 102 204 306 408 510 612 714 816 918 1020 1122 0 102 204 306 408 510 612 714 816 918 1020 1122
180 450 180 450
Legend Legend
150 Pressure: 375 150 Pressure: 375
Suction: Suction:
DR909BE72W DR909BE72W
120 300 120 300
Inches of Water

DR909BB72W DR909BB72W
Inches of Water

mbar

mbar
90 225 90 225

60 150 60 150

30 75 30 75

0 0 0 0
0 60 120 180 240 300 360 420 480 540 600 660 0 60 120 180 240 300 360 420 480 540 600 660

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 46
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 979 & CP 979
15.0 / 20.0 HP Regenerative Blower
19.3
9.8 490.2
248.9
ROTATION
DIRECTION
OUT IN

4" NPSC
PORTS

518.2
20.4
16.88
428.8
1.

B
11.25 9.5 C
285.8 241.3 13.0 2 D
IN 330.2
MM L E

NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.09 DIA. (DR979BE72W) MODEL L (IN/MM) B (IN/MM) C (IN/MM) D (IN/MM) E (IN/MM)
1.375 DIA. (DR979BH72W). DR979BH72W 29.0/736.6 12.25/311.2 11.50/292.1 13.19/335 8.09/205.5
2 .75 (19.1) X 2.00 (50.8) 4X MOUNTING SLOTS.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. DR979BE72W 25.38/644.6 10.25/260.4 8.38/212.9 9.88/250.9 6.88/174.8
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR979BE86W 25.81/655.6 10.25/260.4 8.38/212.9 9.88/250.9 6.88/174.8

Part/ Model Number

DR979BH72W DR979BE72W DR979BE86W DR979BH86W CP979FJ72WLR HiE979BE72W

Specification Units 080718 080704 080702 080719 081777


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 20 15 15 20 15 20
Voltage AC 230/460 230/460 575 575 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - H H H H H H
NEMA Rated Motor Amps Amps (A) 46/23 44/22 14.6 46/23 44/22 44/22
Service Factor - 1.15 1.25 1.15 1.15 1.25 1.25
Max. Blower Amps Amps (A) 60/30 52/26 21 66/33 52/26 52/26
Locked Rotor Amps Amps (A) 294/147 290/145 93 294/147 290/145 290/145
NEMA Starter Size - 3/2 2/2 2 3/2 2/2 2/2
Lbs 350 300 300 350 300 300
Shipping Weight
Kg 158.8 136.1 136.1 158.8 136.1 136.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 47
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 979 & CP 979
15.0 / 20.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant
• CE compliant - Declaration of Conformity on file
• Maximum flow: 1100 SCFM
• Maximum pressure: 80 IWG
• Maximum vacuum: 87 IWG
• Standard motor: 15 HP, TEFC
• Cast aluminum blower housing, impeller & cover; cast iron flanges
(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet & outlet internal muffling
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)
• Chemical duty, high efficiency, inverter duty or industry-specific designs
• Vairous horsepowers for application-specific needs

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models
• Slip-on or face flanges for application-specific needs

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves
• Switches - air flow, pressure, vacuum, or temperature
• External mufflers for additional silencing
• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869 0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
DR979BE72W DR979BE72W
60 149 60 149
DR979BH72W
Inches of Water

DR979BH72W
Inches of Water

mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 0 100 200 300 400 500 600 700 800 900 1000 1100

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0

100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 48
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 1233 & CP 1233
20.0 HP High Pressure Regenerative Blower

IN
MM

NOTES
1 TERMINAL BOX CONNECTOR HOLE 1.38 (35) DIA.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD
DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DR1233BH72W DR1233BH86W CP1233GD72LRW

Specification Units 081375 081377 081379


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS CHEM TEFC-SS
Horsepower - 20 20 20
Voltage AC 208-230/460 575 208-230/460
Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz
Insulation Class - F F F
NEMA Rated Motor Amps Amps (A) 51-46/23 18.4 51-46/23
Service Factor - 1.5 1.15 1.5
Max. Blower Amps Amps (A) 50-46/23 17.8 50-46/23
Locked Rotor Amps Amps (A) 397/199 159 397/199
NEMA Starter Size - 3/2 2 3/2
Lbs 400 400 400
Shipping Weight
Kg 181.4 181.4 181.4

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 49
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 1233 & CP 1233
20.0 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 255 IWG


• Maximum vacuum: 175 IWG
• Standard motor: 20 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Inlet Filter part# 522948
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 51 102 153 204 255 306 357 408 459 510 561 0 51 102 153 204 255 306 357 408 459 510 561
300 747 300 747
Legend Legend
250 Pressure: 622 250 Pressure: 622
Suction: Suction:
DR1233 DR1233
200 498 200 498
Inches of Water
Inches of Water

mbar

mbar
150 374 150 374

100 249 100 249

50 125 50 125

0 0 0 0
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 50
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P13
20.0 / 30.0 HP Regenerative Blower
ROTATION 6” - 8 NPSC FEMALE 17.78
DIRECTION 9.48 1.53/38.86 DEEP 451.71
240.79 FLEX TUBING (2X)

8.47 10.46
215.14 265.7
H
20.50

4.30
109.22 C

4.00
101.60
G
4.72
E 4” - 8 NPT (2X)
119.95
FEMALE THREAD 5.73
9.44 9.50 12.52 145.54
239.76 12.21 241.30 317.88
13.05
310.13 14.54
11.30 331.34
369.32
287.02 .75 X 2.00 SLOT
19.1 X 50.8 (4X) 35.57
903.48

PART NUMBER MODEL C IN/MM H IN/MM G IN/MM E IN/MM


081801 DRP13BP72C 11.30/287 25.01/635.25 12.52/317.88 2/50.8
IN 081802 DRP13BP72D 11.30/287 25.01/635.25 12.52/317.88 2/50.8
MM
081804 DRP13BP86C 11.30/287 25.04/635.25 12.52/317.88 2/50.8
NOTES
1 081801 DRP13BP72C MODEL SHOWN. 081805 DRP13BP86D 11.30/287 25.04/635.25 12.52/317.88 2/50.8
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 081798 DRP13BM72C 10.55/267.97 24.26/616.11 10.77/273.43 1.38/35.05
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. 081797 DRP13BM72D 10.55/267.97 24.26/616.11 10.77/273.43 1.38/35.05

Part/ Model Number

DRP13BP72C DRP13BP72D DRP13BP86C DRP13BP86D DRP13BM72C DRP13BM72D

Specification Units 081801 081802 081804 081805 081798 081797


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS
Horsepower - 30 30 30 30 20 20
Voltage AC 230/460 230/460 575 575 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 70/35 70/35 28 28 49/24.5 49/24.5
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15
Locked Rotor Amps Amps (A) 380/190 380/190 174 174 306/153 306/153
Max. Blower Amps Amps (A) 110/55 110/55 36 36 64/32 64/32
NEMA Starter Size - 3/3 3/3 3 3 3/2 3/2
Lbs 687 687 687 687 592 592
Shipping Weight
Kg 311.6 311.6 311.6 311.6 268.5 268.5
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 51
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P13
20.0 / 30.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 115 IWG


• Maximum vacuum: 103 IWG
• Standard motor: 30 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings


(part# 511569)

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738 0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DRP13BP72C DRP13BP72C
80 200 80 200
DRP13BM72C DRP13BM72C
Inches of Water

Inches of Water
mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding

Motor Winding
Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C
Blower Air

Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 52
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S13
20.0 / 30.0 HP High Pressure Regenerative Blower
3
OUT
NOTES
1 TERMINAL BOX CONNECTOR HOLE 2.50 (63.5) DIA.
2 4”-8 NPSC FEMALE THREAD, BOTH PORTS

20.49
520.4
3 LABEL INDICATES ROTATION DIRECTION AND
“IN & OUT” PORT LOCATIONS.
5 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
6 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

IN
IN 2
MM 35.57
903.5
12.33
313.2
BOTH
PORTS
215.1
8.47

25.04
636
19.79
502.7
11.28
286.5
1
109.2
4.3

1.08
27.4
4.72 10.77 4.24
107.7 SLOTS
119.9 273.6
9.44 13.63 9.50 .75x2.00
239.8 346.2 241.3 (19x50.8)
(4) PLACES
11.30 14.54
287.0 369.3
SECTION VIEW A-A

Part/ Model Number

DRS13BP72 DRS13BP86 DRS13BM72

Specification Units 081800 081803 081799


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS ODP-CS
Horsepower - 30 30 20
Voltage AC 230/460 575 230/460
Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz
Insulation Class - F F F
NEMA Rated Motor Amps Amps (A) 78/39 28 49/24.5
Service Factor - 1.15 1.15 1.15
Max. Blower Amps Amps (A) 80/40 32 70/153
Locked Rotor Amps Amps (A) 380/190 174 306/153
NEMA Starter Size - 3/3 3 3/2
Lbs 646 646 562
Shipping Weight
Kg 293 293 254.9

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 53
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S13
20.0 / 30.0 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 195 IWG


• Maximum vacuum: 132 IWG
• Standard motor: 30 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings


(part# 511569)

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 136 272 408 544 680 816 952 1087 1223 1359 1495 0 136 272 408 544 680 816 952 1087 1223 1359 1495
210 523 210 523
Legend Legend
175 Pressure: 436 175 Pressure: 436
Suction: Suction:
DRS13 DRS13
140 348 140 348
Inches of Water

Inches of Water
mbar

mbar
105 261 105 261

70 174 70 174

35 87 35 87

0 0 0 0
0 80 160 240 320 400 480 560 640 720 800 880 0 80 160 240 320 400 480 560 640 720 800 880

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding

Motor Winding
Temp Rise °C

Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C

Temp Rise °C
Blower Air

Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 54
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 14 & CP 14
20.0 / 25.0 / 30.0HP Regenerative Blower
29.25 17.57
743.0 446.3
7.5 9.72
190.5 247.7
SEE NOTE 1 SEE NOTE 4"-8 NPSC
1 OUT IN
FEMALE THREAD
BOTH PORTS
(CAST IRON)

ROTATION
DIRECTION
701.0
27.6

23.46
595.9
15.31 DIA

12.88
327.2
388.9
23.32 DIA
D 592.3

9.65
3.00 245.1
76.2 13.11
11.00 333
279.4 SLOTS
.75 x 2.00 11.57
IN 17.00 (19.1 x 50.8) 293.9
MM 431.8 4X PLACES

NOTES L
1 LIFTING SLOT: 1.00 X 1.70 (25.4 X 43.2)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. MODEL L (IN/MM) D (IN/MM)
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. DR14DW72MW 31.55/801.4 1.98/50.3

Part/ Model Number

DR14DW72MW DR14DW86MW DR14DT72MW DR14BH72MW CP14FK72MWLR HiE14DW72MW

Specification Units 081476 081479 081483 081480 081490 081497


Motor Enclosure - Shaft Mtl. - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS
Horsepower - 30 30 25 20 30 30
Voltage AC 230/460 575 230/460 230/460 230/460 230/460
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 66/33 26.5 58/29 46/23 66/33 66/33
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15
Max. Blower Amps Amps (A) 90/45 32.8 90/45 60/30 90/45 90/45
Locked Rotor Amps Amps (A) 430/215 172 304/152 294/147 430/215 430/215
NEMA Starter Size - 3/3 3 3/3 3/2 3/3 3/3
Lbs 696 694 650 600 696 696
Shipping Weight
Kg 315.7 314.8 294.8 272.2 315.7 315.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 55
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR 14 & CP 14
20.0 / 25.0 / 30.0HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 150 IWG


• Maximum vacuum: 120 IWG
• Standard motor: 30 HP, TEFC

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870 0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
180 450 180 450
Legend Legend
150 Pressure: 375 150 Pressure: 375
Suction: Suction:
DR14DW72MW DR14DW72MW
120 DR14DT72MW 300 120 DR14DT72MW 300
Inches of Water

Inches of Water

DR14BH72MW DR14BH72MW
mbar

mbar
90 225 90 225

60 150 60 150

30 75 30 75

0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 0 100 200 300 400 500 600 700 800 900 1000 1100

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding

Motor Winding
Temp Rise °C

Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C

Temp Rise °C
Blower Air

Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 56
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P15
40.0 / 60.0 HP Regenerative Blower

24.04 REF
610.6
12.38
314.5
IA.
39.82 1D ) 9.69
2.81.4 ACES
1011.4 7 PL 246.1
A (2
2

OUT IN

290.1
11.42
OUT IN
23.30 DIA.

750.1
29.53
32.01 REF.

752.9
29.64
591.8

813.1
307.8
12.12

149.4
5.88
14.14
359.2
1

3
A
10.34
IN 14.29 11.25 3.00 262.6
MM 363 285.8 76.2
12.50
11.29 17.25 317.5
NOTES .75 X 2.00 SLOT
286.8 438.2 19 50.8
1 TERMINAL BOX CONNECTOR HOLE 2.50 (63.5) DIA. 15.62
(4) PLACES 396.7
2 4-8 NPSC FEMALE THREAD, BOTH PORTS
3 PRESSURE CONNECTION 6-8 NPSC FEMALE THREAD. SECTION VIEW A-A
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/ Model Number

DRP15EE72C DRP15EE72D DRP15BQ72C DRP15BQ72D DRP15BQ86C DRP15BQ86D

Specification Units 081499 081629 081501 081500 TBD TBD


Motor Enclosure - Shaft Mtl. - ODP-CS ODP - CS ODP - CS ODP - CS ODP - CS ODP - CS
Horsepower - 60 60 40 40 40 40
Voltage AC 230/460 230/460 230/460 230/460 575 575
Phase - Frequency - Three-60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz
Insulation Class - F F F F F F
NEMA Rated Motor Amps Amps (A) 140/70 140/70 96/48 96/48 38.4 38.4
Service Factor - 1.15 1.15 1.15 1.15 1.15 1.15
Locked Rotor Amps Amps (A) 870/435 870/435 630/315 630/315 540/270 540/270
Max. Blower Amps Amps (A) 170/85 170/85 160/80 160/80 64 64
NEMA Starter Size - 5/4 5/4 4/3 4/3 3 3
Lbs 1025 1025 923 923 923 923
Shipping Weight
Kg 464.9 464.9 418.7 418.7 418.7 418.7
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 57
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR P15
40.0 / 60.0 HP Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 150 IWG


• Maximum vacuum: 115 IWG
• Standard motor: 60 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings


(part# 516264)

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738 0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
150 373 150 373
Legend Legend
125 Pressure: 311 125 Pressure: 311
Suction: Suction:
DRP15EE72D DRP15EE72D
100 DRP15BQ72C 249 100 DRP15BQ72C 249
Inches of Water

Inches of Water
mbar

mbar
75 187 75 187

50 124 50 124

25 62 25 62

0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding

Motor Winding
Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C

Temp Rise °C
Blower Air

Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 58
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S15
40.0 HP High Pressure Regenerative Blower
5 IN

IN
OUT
594.4
23.4
13.1
332.7
9.72
2 OUT
246.9
39.2
12.9 995.7 4
BOTH 327.7 A
PORTS

269.2
10.6

726.4
28.6
IN
MM 1

355.6
14.0
NOTES
1 TERMINAL BOX CONNECTOR HOLE .88 (22) DIA. 3
2 4-8 NPSC FEMALE THREAD, BOTH PORTS.
13.4 A
3 FOUR MOUNTING SLOTS .75 (19) X 2.00 (50.8). 12.50

152.4
6.00
4 TWO LIFTING SLOTS 1.00 (25.4) X 1.70 (43.2). 340.4 10.4 11.18 317.5
5 LABEL INDICATES ROTATION DIRECTION AND 264.2 284.0 10.8
274.3 15.6
“IN & OUT” PORT LOCATIONS. 17.25 11.6
6 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 438.2 294.6 396.2
7 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. SECTION VIEW A-A

Part/ Model Number

DRS15BQ72 DRS15BQ86

Specification Units 081502 TBD


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS
Horsepower - 40 40
Voltage AC 230/460 575
Phase - Frequency - Three-60 Hz Three-60 Hz
Insulation Class - F F
NEMA Rated Motor Amps Amps (A) 96/48 38.4
Service Factor - 1.15 1.15
Max. Blower Amps Amps (A) 140/70 52
Locked Rotor Amps Amps (A) 630/315 216
NEMA Starter Size - 4/3 3
Lbs 923 923
Shipping Weight
Kg 418.7 418.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 59
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Industrial / Chemical Processing Blowers
DR S15
40.0 HP High Pressure Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum flow: 925 SCFM


• Maximum pressure: 200 IWG
• Maximum vacuum: 134.7 IWG
• Standard motor: 40 HP, ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings
• Quiet operation within OSHA standards when properly piped or muffled -
1 inlet muffler included (part# 516264)

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz
Air Flow Rate - m3/hour
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
240 600

Legend
200 Pressure: 500
Suction:
160 DRS15 400
Inches of Water

mbar

120 300

80 200

40 100

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100

Air Flow Rate - SCFM


100
Motor Winding
Temp Rise °C

50

0
Temperature curves are based on standard model
100
Temp Rise °C
Blower Air

50

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS C 60
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Environmental / Chemical Processing Blowers
Our environmental EN blowers are designed the same as the DR blowers, except added features
include:

Heavy duty cast aluminum manifold


Our spark resistant housing, cover, impeller, muffler tower, and manifold are

vacuum impregnated

Teflon® lip seal in a stainless steel case standard for leakage containment to 25 cc/min or less
Explosion-proof motors standard and available in a variety of world voltages
All metal-to-metal surfaces are sealed with RTV sealant
Various UL explosion-proof listings. Consult factory.

Environmental (EN) regenerative blowers are also available in our Chemical Processing (CP)
configuration:

Chem-ToughTM surface conversion corrsion resistant treatment for all castings


Teflon® lip seal in a stainless steel case standard for leakage containment to 25 cc/min or less
Chemical duty motors with 303 stainless steel motor shafts
Stainless steel hardware throughout
Nickel plated flanges and muffler retainers

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Environmental / Chemical Processing Blowers
EN 101 & CP 101
.5 HP Sealed Regenerative w/Explosion-Proof Motor

4.13
104.9
ROTATION
DIRECTION

1
6.13
155.7

7.74

14.01
355.9
195.6

12.51
317.8
244.6
9.63

140.5
5.53

1.00
25.4

0.40
10.2
IN OUT

.38 (9.6) DIA


4.65 2X MTG. HOLES 1 - 11 1/2 NPSC 3.12
118.1 3.25 79.3
8.62 FEMALE THREAD
BOTH PORTS 82.6
219.0
13.75 6.50
IN 349.3
MM 7.52 165.1
191.0
NOTES
1 TERMINAL BOX CONNECTOR HOLE .75” NPT
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN101AG58L EN101AG91L CP101FN58LR CP101FN91LR

Specification Units 038171 038019 080622 038950


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - .5 .5 .5 .5
Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 115/230 230/460 115/230 230/460
Max. Blower Amps Amps (A) 7.4/3.7 .90/.45 7.4/3.7 .90/.45
Locked Rotor Amps Amps (A) 6/3 1.5/.75 6/3 1.5/.75
Service Factor Amps (A) 38/19 8.9/4.5 38/19 8.9/4.5
Starter Size - 0/00 00/00 0/00 00/00
Thermal Protection - 1.0 1.0 1.0 1.0
XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Lbs 47 47 47 47
Shipping Weight
Kg 21.3 21.3 21.3 21.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 101 & CP 101
.5 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 25 IWG


• Maximum vacuum: 23 IWG
• Standard motor: 0.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 5.1 10.2 15.3 20.4 25.5 30.6 35.7 40.8 45.9 51.0 56.1 0 5.1 10.2 15.3 20.4 25.5 30.6 35.7 40.8 45.9 51.0 56.1
30 74.7 30 74.7
Legend Legend
25 Pressure: 62.2 25 Pressure: 62.2
Suction: Suction:
EN101 EN101
20 49.8 20 49.8
Inches of Water
Inches of Water

mbar

mbar
15 37.3 15 37.3

10 24.9 10 24.9

5 12.5 5 12.5

0 0 0 0
0 3 6 9 12 15 18 21 24 27 30 33 0 3 6 9 12 15 18 21 24 27 30 33

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding
Temp Rise °C

Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.comcom ____
Environmental / Chemical Processing Blowers
EN 303 & CP 303
.5 HP Sealed Regenerative w/Explosion-Proof motor
1
12.04 9.61
305.8 244.1

177.3
6.98
146.1
5.75
274.8
10.82

147.1
5.79

34.8
1.37

0.48
12.2
T
OU
IN
3.38 3.27 1.97
.397 DIA.
85.9 83.1 10 50
(4) MTG HOLES 3.94
IN 10.90
MM 100.1
276.9 4.06
NOTES 103.1
1 1/4" - 11 1/2 NPSC
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD> FEMALE THREAD 8.91
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. BOTH PORTS
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. 226.3

Part/Model Number

EN303AG58L EN303AG91L CP303FN58LR CP303FN91LR

Specification Units 038172 038026 080247 038954


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - .5 .5 .5 .5
Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 115/230 230/460 115/230 230/460
Max. Blower Amps Amps (A) 9.0/4.5 1.5/.75 9.0/4.5 1.5/.75
Locked Rotor Amps Amps (A) 7.2/3.6 1.63/.83 7.2/3.6 1.63/.83
Service Factor Amps (A) 38/19 8.9/4.45 38/19 8.9/4.45
Starter Size - 0/00 00/00 0/00 00/00
Thermal Protection - 1.0 1.35 1.0 1.35
XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Lbs 52 52 52 52
Shipping Weight
Kg 23.6 23.6 23.6 23.6

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 303 & CP 303
.5 HP Sealed Regenerative w/Explosion-Proof motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 50 IWG


• Maximum vacuum: 45 IWG
• Standard motor: 0.5 HP, explosion-proof

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
EN303 EN303
40 100 40 100
Inches of Water
Inches of Water

mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 0 5 10 15 20 25 30 35 40 45 50 55

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D4
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 404 & CP 404
1.0 HP Sealed Regenerative w/Explosion-Proof Motor
6.66
169.2
4.92
ROTATION DIRECTION
L 125

11
29 .5 D
2.1 IA
12.23

182.4
311.2

7.18

159.5
6.28

0.44
11.2
3.04 3.75 5.12
.47 DIA.
76.2 95.3 11.9 130
IN (4) MTG. HOLES
11.63 8.93
MM 1 1/2 - 11 1/2 NPSC
295.4 FEMALE THREAD 226.8
BOTH PORTS
NOTES 10.13
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT. 257.3
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. MODEL L (IN/MM)
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. EN404AR58ML 16.41/416.8
EN404AR72ML 15.50/393.7

Part/Model Number

EN404AR58ML EN404AR72ML CP404FQ58MLR CP404FQ72MLR

Specification Units 038173 038174 080075 038958


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 1.0 1.0 1.0 1.0
Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 115/230 208-230/460 115/230 208-230/460
Max. Blower Amps Amps (A) 11.4/5.69 3.2/1.6 11.4/5.69 3.2/1.6
Locked Rotor Amps Amps (A) 14.4/7.2 3.6/1.8 14.4/7.2 3.6/1.8
Service Factor Amps (A) 72/36 20.2/10.1 72/36 20.2/10.1
Starter Size - 0/00 00/00 0/00 00/00
Thermal Protection - 1.0 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 81 64 81 64
Shipping Weight
Kg 36.7 29 36.7 29

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 404 & CP 404
1.0 HP Sealed Regenerative w/Explosion-Proof Motor *ATEX model certified

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 52 IWG


• Maximum vacuum: 48 IWG
• Standard motor: 1.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
EN404 EN404
40 100 40 100
Inches of Water
Inches of Water

mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 454 & CP 454
1.5 HP Sealed Regenerative w/Explosion-Proof Motor
18.70 12.5
ROTATION DIRECTION
475.0 317.5

120.7
4.75
13.53
343.7

177.3
IN OUT

6.98

48.8
1.92

10.7
0.42
3.27 1.78
83.1 45.2 .59 DIA. 1
4.50 15
114.3 (6) MTG. HOLES
4.75
120.6
13.10
332.7
1 1/2 - 11 1/2 NPSC 5.38
FEMALE THREAD 136.7
IN BOTH PORTS
10.30
MM
261.6
NOTES
11.4 REF.
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 289.6
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN454W58ML EN454W72ML CP454W72MLR CP454FR72MLR

Specification Units 080487 080488 080490 080494


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-CS CHEM XP-SS
Horsepower - 1.5 1.5 1.5 1.5
Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz
Voltage AC 115/208-230 230/460 230/460 230/460
Motor Nameplate Amps Amps (A) 15/7.9-7.5 4.6/2.3 4.5/2.3 4.6/2.3
Max. Blower Amps Amps (A) 19/10.9-9.5 5.6/2.8 5.6/2.8 5.6/2.8
Locked Rotor Amps Amps (A) 96-48 32/16 32/16 32/16
Service Factor - 1/0 00/00 00/00 00/00
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 90 84 84 84
Shipping Weight
Kg 40.8 38.1 38.1 38.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D7
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 454 & CP 454
1.5 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 65 IWG


• Maximum vacuum: 59 IWG
• Standard motor: 1.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 26 51 77 102 127 153 178 204 229 255 280 0 26 51 77 102 127 153 178 204 229 255 280
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
EN454 EN454
Inches of Water
Inches of Water

60 149 60 149
mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D8
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 505 & CP 505
2.0 / 2.5 HP Sealed Regenerative w/Explosion-Proof Motor

IN
MM

NOTES
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN505AX58ML EN505AX72ML CP505FS58MLR CP505FS72MLR

Specification Units 038177 038178 080655 038962


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 2.0 2.0 2.0 2.0
Phase - Frequency - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Voltage AC 115/230 230/460 115/230 230/460
Motor Nameplate Amps Amps (A) 22/11 5.8/2.9 22/11 5.8/2.9
Max. Blower Amps Amps (A) 24/12 6.4/3.2 24/12 6.4/3.2
Locked Rotor Amps Amps (A) 112/56 56/28 112/56 56/28
Service Factor - 1/0 0/0 1/0 0/0
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 92 84 92 84
Shipping Weight
Kg 41.7 38.1 41.7 38.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D9
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 505 & CP 505
2.0 / 2.5 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 75 IWG


• Maximum vacuum: 70 IWG
• Standard motor: 2.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 26 51 77 102 127 153 178 204 229 255 280 0 26 51 77 102 127 153 178 204 229 255 280
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
EN505AX72ML EN505AX72ML
60 149 60 149
Inches of Water

EN505AX58ML EN505AX58ML
Inches of Water

mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 10
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 513 & CP 513
1.5 HP Sealed Regenerative w/Explosion-Proof Motor
15.70 14.21
398.8 360.9 ROTATION DIRECTION
4.42
112.3 6.69
170

181.9
15.92
404.4

223.5
IN OUT

8.8

2.24
56.9

12.7
0.5
3.72 5.50 4.75
.59 DIA. 120.6
94.5 139.7 15
(4) MTG. HOLES
13.64
5.53
346.5 140
IN 1 1/2 - 11 1/2 NPSC 12.8
13.87
MM FEMALE THREAD
352.3 325.1
BOTH PORTS
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN513W58L EN513W72L CP513FR58LR CP513FR72LR

Specification Units 038183 038037 038966


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 1.5 1.5 1.5 1.5
Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 115/208-230 230/460 115/208-230 230/460
Max. Blower Amps Amps (A) 15/7.9-7.5 4.6/2.3 15/7.9-7.5 4.6/2.3
Inrush Amps Amps (A) 19.4/9.7-9.0 5.4/2.7 19.4/9.7-9.0 5.4/2.7
Service Factor Amps (A) 84-42 32/16 84-42 32/16
Starter Size - 1/0 00/00 1/0 00/00
Thermal Protection - 1.0 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 99 93 99 93
Shipping Weight
Kg 44.9 42.2 44.9 42.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 11
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 513 & CP 513
1.5 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 88 IWG


• Maximum vacuum: 75 IWG
• Standard motor: 1.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
EN513 EN513
60 149 60 149
Inches of Water
Inches of Water

mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 12
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 523 & CP 523
3.0 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor
19.19 14.21
487.4 360.9 SEE NOTE
6.56
1 ROTATION DIRECTION
166.6

146.1
5.75
7.16
408.7
16.01

14.38
365.3
IN OUT

223.8
8.69

2.22
60.5

0.50
12.7
4.75
5.56 5.50
.59 DIA. 120.6
141.2 139.7 15
(4) MTG. HOLES 5.71
15.68
145
398.3
IN 11.42
MM 290.1
1 1/2 - 11 1/2 NPSC
FEMALE THREAD 12.8
NOTES BOTH PORTS
325.1
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN523M5L EN523M72L CP523FU5LR CP523FU72LR

Specification Units 038223 038184 TBD 038968


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 3 3 3 3
Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 230 230/460 230 230/460
Max. Blower Amps Amps (A) 15.5-14.5 7.4/3.7 15.5-14.5 7.4/3.7
Locked Rotor Amps Amps (A) 18.1-16.7 8/4 18.1-16.7 8/4
Service Factor Amps (A) 94-88 62/31 94-88 62/31
Starter Size - 1 0/0 1 0/0
Thermal Protection - 1.0 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D I-D I-D I-D
Lbs 126 126 150 126
Shipping Weight
Kg 57.2 57.2 68 57.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 13
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 523 & CP 523
3.0 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 140 IWG


• Maximum vacuum: 135 IWG
• Standard motor: 3.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
180 450 180 450
Legend Legend
150 Pressure: 375 150 Pressure: 375
Suction: Suction:
EN523 EN523
120 300 120 300
Inches of Water
Inches of Water

mbar

mbar
90 225 90 225

60 150 60 150

30 75 30 75

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 14
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 6 & CP 6
5.0 HP Sealed Regenerative w/Explosion-Proof Motor
16.38
416.1
L 7.75
196.9 2 - 11 1/2 NPSC
6.37 FEMALE THREAD
4.19 BOTH PORTS
161.8
106.4 0.95
24.6

OU

141.7
IN

5.58
T
16.222
423.9
16.69

215.9
8.50

209.6
8.25

101.6
4.00
7.18 7.00 5.98
2.00
IN 182.4 177.8 50.8 NOTE 1 151.9
MM 8.00
16.18
.562 DIA. 203.2
411.0 14.3
NOTES (4) MTG. HOLES 11.50
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD
292.1
POSITIONED AT 12 O’CLOCK. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. EN6F72L 20.5/520.7
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.
EN6F5L 20.84/529.2

Part/Model Number

EN6F5L EN6F72L EN6F86L CP6FW5LR CP6FW72LR

Specification Units 038361 038180 038438 TBD 038978


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 5.0 5.0 5.0 5.0 5.0
Phase - Frequency Voltage - Single-60 hz Three-60 hz Three-60 hz Single-60 hz Three-60 hz
Motor Nameplate Amps AC 230 230/460 575 230 230/460
Max. Blower Amps Amps (A) 19.5 14/7 5.7 19.5 14/7
Locked Rotor Amps Amps (A) 23 14/7 6.3 23 14/7
Service Factor Amps (A) 175 152/76 38 175 152/76
Starter Size - 2 1/0 0 2 1/0
Thermal Protection - 1.0 1.0 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 190 167 167 190 167
Shipping Weight
Kg 86.2 75.7 75.7 86.2 75.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 15
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 6 & CP 6
5.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 110 IWG


• Maximum vacuum: 85 IWG
• Standard motor: 5.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards
• Muffler included (part# 522948)

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
EN6F72L EN6F72L
80 200 80 200
Inches of Water

EN6F5L EN6F5L
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 16
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN / CP 633
7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor
1.03 A
C
26.2
DIRECTION
OF
ROTATION

ROTATION
11.71
297.4

10.59
269.0
3.22
81.8
IN OUT

5.1
.20
6.22
.98 (2X) 158.0 6.10
24.9 2.66 154.9 2" - 11 1/2 NPSC
11.811 D FEMALE THREAD
300.0 67.6 18.41 BOTH PORTS
18.06 467.6
458.7
IN
MM .512
MTG. HOLE
13.0 DETAIL
15.0
.591

(4X)
NOTES MODEL A B C D
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD. EN633 18.1 18.94 16.7 17.3
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. EN833 18.2 19.59 18.0 17.6

Part/Model Number

EN633BA72LM CP633FY72LR

Specification Units 081698 081697


Motor Enclosure - Shaft Mtl. - XP-CS CHEM XP-SS
Horsepower - 7.5 7.5
Voltage AC 208-230/460 208-230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz
Insulation Class - B B
NEMA Rated Motor Amps Amps (A) 20-18/9.3 20-18/9.3
Service Factor - 1.0 1.0
Max. Blower Amps Amps (A) 17/8.5 17/8.5
Locked Rotor Amps Amps (A) 177/88.7 177/88.7
Starter Size - 1/1 1/1
Lbs 288 288
Shipping Weight
Kg 130.6 130.6

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 17
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN / CP 633
7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 200/195 IWG
• Maximum vacuum: 155/155 IWG
• Standard motor: 7.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz
Air Flow Rate - m3/hour
34 68 102 136 170 204 238 272 306 340
300 750

625

250
500
Inches of Water

200
mbar

375

150
250

100
125

50
0
20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM


100
Motor Winding
Temp Rise °C

50

0
Temperature curves are based on standard model
100
Temp Rise °C
Blower Air

50

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
0
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
0
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 18
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 656 & CP 656
3.0 HP Sealed Regenerative w/Explosion-Proof Motor
19.37 15.42
STD. DIRECTION
492.0 OF ROTATION 391.7 7.19
182.6

176.8
6.96

136.7
5.38
15.17

1
382.5

189.5
7.46
2" NPSC
STRAIGHT THDS
BOTH PORTS

2.31
4.92

58.7
0.59

0.64
17.3
4.14 5.51 15 125
105.2 140 (4X) MTG 11.420
IN HOLES
290.1
MM
15.12 12.81
382.5 325.4
NOTES
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN656M5XL EN656M72XL EN656M86XL CP656FU72XLR

Specification Units 080060 080059 080058 080142


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS
Horsepower - 3 3 3 3
Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz
Voltage AC 208-230 208-230/460 575 208-230/460
Motor Nameplate Amps Amps (A) 15.5-14.5 7.4/3.7 3.0 7.4/3.7
Max. Blower Amps Amps (A) 17 10/5 4.1 10/5
Locked Rotor Amps Amps (A) 95-86 54/27 21.6 54/27
Service Factor - 1 0/0 0 0/0
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 142 117 117 117
Shipping Weight
Kg 64.4 53.1 53.1 53.1

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 19
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 656 & CP 656
3.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 75 IWG
• Maximum vacuum: 73 IWG
• Standard motor: 3.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
90 224 90 224
Legend Legend
75 Pressure: 187 75 Pressure: 187
Suction: Suction:
EN656M72XL EN656M72XL
60 149 60 149
Inches of Water

EN656M5XL EN656M5XL
Inches of Water

mbar

mbar
45 112 45 112

30 75 30 75

15 37 15 37

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 20
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower w/Explosion-proof Motor
23.35
10.33
593.1
15.36 262.4
5.73

2.61
66.3
390.1
145.5

ROTATION
OUT IN DIRECTION

233.2
9.18
1

166.9
2 1/2" NPSC

6.57
427.2
16.82
493.5
19.43

FEMALE THREADS
BOTH PORTS

258.6
10.18
437.9
17.24

9.50 8.50
1.75
44.5 241.3 215.9
IN .75 X 2.00 SLOT 10.00
MM 6.04 13.00 19/50.8 254
153.4 330.2 (4) PLACES 16.64
422.7
NOTES
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN757FL5MWL CP757FX5MWLR

Specification Units 081333 080616


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS CHEM XP-SS
Horsepower - 5.5 5.5
Phase - Frequency - Single-60 hz Single-60 hz
Voltage AC 230 230
Motor Nameplate Amps Amps (A) 21.7 21.7
Max. Blower Amps Amps (A) 29.9 29.9
Locked Rotor Amps Amps (A) 155 155
Service Factor - 1 1
Starter Size - 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D I-D
Lbs 158 158
Shipping Weight
Kg 71.7 71.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 21
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower w/Explosion-proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 80 IWG


• Maximum vacuum: 75 IWG
• Standard motor: 5.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz
Air Flow Rate - m3/hour
0 68 136 204 272 340 408 442 510 578 546 714
120 300
Legend
100 Pressure: 250
Suction:
EN757FL5WL
80 200
Inches of Water

mbar

60 150

40 100

20 50

0 0
0 40 80 120 160 200 240 260 300 340 380 420
120
Air Flow Rate - SCFM
100
Motor Winding
Temp Rise °C

50

0
Temperature curves are based on standard model
100
Temp Rise °C
Blower Air

50

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 22
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 757 & CP 757
3.0 / 5.0 HP Sealed Regenerative w/Explosion-Proof Motor
16.75
L 425.5
ROTATION
DIRECTION

IN
NAMEPLATE

7.18
MOTOR MODEL:
17.44

182
PART NO.
443

166.9
6.57
2 1/2" NPSC

234.4
FEMALE THREADS

9.23
BOTH PORTS

IN 5.73 OUT

2.61
66.3
146.1

0.88
15.36 10.37
388.6 263.4
5.60 2.84 15.35
0.63 142.2
16 1.99 16.09 389.9
50.5 408.7
181.6
7.15
50.8
2.0

IN
5.59
142

MM R0.31
7.9
CL OF BLOWER
NOTES
1 TERMINAL BOX CONNECTOR HOLE .75 NPT. MODEL L (IN/MM)
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. EN757M72XL 19.72/500.9
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. EN757F72XL 21.00/533.4

Part/Model Number

EN757M72XL EN757M86XL EN757F72XL CP757FW72XLR CP757FU72XLR

Specification Units 081176 081177 081174 081180 081181


Motor Enclosure - Shaft - XP-CS XP-CS XP-CS CHEM XP-SS CHEM XP-SS
Mtl. Horsepower - 3.0 3.0 5.0 5.0 3.0
Voltage AC 208-230/460 575 208-230/460 208-230/460 208-230/460
Phase - Frequency - Three-60 Hz Three-60 Hz Three - 60 Hz Three-60 Hz Three - 60 Hz
Insulation Class - B B B B B
NEMA Rated Motor Amps Amps (A) 7.2/3.6 3.0 14/7 14/7 7.2/3.6
Service Factor - 1.0 1.0 1.0 1.0 1.0
Maximum Blower Amps Amps (A) 10/5 4.0 15/7.5 15/7.5 10/5
Locked Rotor Amps Amps (A) 54/47 22 152/76 152/76 54/27
Starter Size - 0/0 0 1/1 1/1 0/0
Lbs 158 158 158 158 158
Shipping Weight
Kg 71.7 71.7 71.7 71.7 71.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 23
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 757 & CP 757
3.0 / 5.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 80 IWG


• Maximum vacuum: 75 IWG
• Standard motor: 5.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 51 102 153 204 255 306 357 408 459 510 561 0 51 102 153 204 255 306 357 408 459 510 561
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
EN757F72XL EN757F72XL
80 200 80 200
Inches of Water

EN757M72XL EN757M72XL
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 24
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower w/Explosion-proof Motor
23.35
10.33
593.1
15.36 262.4
5.73

2.61
66.3
390.1
145.5

ROTATION
OUT IN DIRECTION

233.2
9.18
1

166.9
2 1/2" NPSC

6.57
427.2
16.82
493.5
19.43

FEMALE THREADS
BOTH PORTS

258.6
10.18
437.9
17.24

9.50 8.50
1.75
44.5 241.3 215.9
IN .75 X 2.00 SLOT 10.00
MM 6.04 13.00 19/50.8 254
153.4 330.2 (4) PLACES 16.64
422.7
NOTES
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN757FL5MWL EN808FL5MWL CP757FX5MWLR CP808FX5MWLR

Specification Units 081333 081231 080616


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 5.5 5.5 5.5 5.5
Phase - Frequency - Single-60 hz Single-60 hz Single-60 hz Single-60 hz
Voltage AC 230 230 230 230
Motor Nameplate Amps Amps (A) 21.7 21.7 21.7 21.7
Max. Blower Amps Amps (A) 29.9 29.9 29.9 29.9
Locked Rotor Amps Amps (A) 155 155 155 155
Service Factor - 1 1 1 1
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Class B - Pilot Class B - Pilot Class B - Pilot
XP Motor Class - Group - Duty I-D Duty I-D Duty I-D Duty I-D
Lbs 158 338 158 338
Shipping Weight
Kg 71.7 153.3 71.7 153.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 25
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower w/Explosion-proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 80 IWG


• Maximum vacuum: 75 IWG
• Standard motor: 5.0 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz
Air Flow Rate - m3/hour
0 68 136 204 272 340 408 442 510 578 546 714
120 300
Legend
100 Pressure: 250
Suction:
EN808FL5MWL
80 200
Inches of Water

mbar

60 150

40 100

20 50

0 0
0 40 80 120 160 200 240 260 300 340 380 420

Air Flow Rate - SCFM


100
Motor Winding
Temp Rise °C

50

0
Temperature curves are based on standard model
100
Temp Rise °C
Blower Air

50

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 26
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 808 & CP 808 Three-Phase
Sealed Regenerative Blower w/Explosion-proof Motor
23.56
598.4 18.5
470

ROTATION
DIRECTION

282.7
11.13
480.3
18.91
21.12

NOTE 1
537

6.75
171.5

298.7
11.74
IN OUT

22.4
0.88
3.58
90.9
8.75 7.38 3.55
.562 DIA.
222.3 187.5 14.3 90.2
(8) MTG. HOLES 7.09
8.60 8.50
217.4 215.9 1.25 180.1

6.92 14.15 31.8


2 1/2 - 8 NPSC 14.76
IN 175.8 359.4 FEMALE THREAD 374.9
MM BOTH PORTS
15.75
400.1
NOTES
1 TERMINAL BOX CONNECTOR HOLE .75 NPT CONDUIT. 17.43
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 442.7
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN808BA72MXL EN808BA86MXL CP808FY72MXLR

Specification Units 081229 081230 081234


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS
Horsepower - 7.5 7.5 7.5
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz
Voltage AC 230/460 575 230/460
Motor Nameplate Amps Amps (A) 18.6/9.3 7.4 18.6/9.3
Max. Blower Amps Amps (A) 22.0/11.0 8.1 22.0/11.0
Locked Rotor Amps Amps (A) 126/63 56 126/63
Service Factor - 1/1 1 1/1
Starter Size - 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 287 287 287
Shipping Weight
Kg 130.2 130.2 130.2

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 27
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 808 & CP 808 Three-Phase
Sealed Regenerative Blower w/Explosion-proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 85 IWG


• Maximum vacuum: 90 IWG
• Standard motor: 7.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Air knives (used on blow-off applications)
• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
EN808 EN808
80 200 80 200
Inches of Water
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 28
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN / CP 833
7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor
1.03 A
C
26.2
DIRECTION
OF
ROTATION

ROTATION
11.71
297.4

10.59
269.0
3.22
81.8
IN OUT

5.1
.20
6.22
.98 (2X) 158.0 6.10
24.9 2.66 154.9 2" - 11 1/2 NPSC
11.811 D FEMALE THREAD
300.0 67.6 18.41 BOTH PORTS
18.06 467.6
458.7
IN
MM .512
MTG. HOLE
13.0 DETAIL
15.0
.591

(4X)
NOTES MODEL A B C D
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT FEMALE THREAD. EN633 18.1 18.94 16.7 17.3
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. EN833 18.2 19.59 18.0 17.6

Part/Model Number

EN833BA72LM CP833FY72LRM

Specification Units 081712 081708


Motor Enclosure - Shaft Mtl. - XP-CS CHEM XP-SS
Horsepower - 7.5 7.5
Voltage AC 208-230/460 208-230/460
Phase - Frequency - Three - 60 Hz Three - 60 Hz
Insulation Class - B B
NEMA Rated Motor Amps Amps (A) 20-18/9.3 20-18/9.3
Service Factor - 1.0 1.0
Max. Blower Amps Amps (A) 19/9.5 19/9.5
Locked Rotor Amps Amps (A) 177/88.7 177/88.7
Starter Size - 1/1 1/1
Lbs 297 297
Shipping Weight
Kg 134.7 134.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 29
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN / CP 833
7.5 HP High Pressure Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 200/195 IWG
• Maximum vacuum: 155/155 IWG
• Standard motor: 7.5 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz
Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374
300
750

250 625

200 500

150
mbar
Inches of

375
Water

100 250

50 125

0 0
0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM


100
Motor Winding
Temp Rise °C

50

0
Temperature curves are based on standard model
100
Temp Rise °C
Blower Air

50

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 30
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 858 & CP 858
7.5 / 10.0 HP Sealed Regenerative w/Explosion-Proof Motor
18.60
L 472.4 2 1/2" NPSC
23.34 15.48 FEMALE THREAD
393.2 BOTH PORTS
592.8
6.92 13.53 7.09
1.91 180.1
175.8 343.7
48.5

ROTATION DIRECTION

OUT IN

8.17
207.5
622.3
24.5

21.81
554.0
481.3
18.95

10.50
266.7
NOTE 1

6.75
13.00 171.4
IN
MM 330.2 1.75 8.21
10.75 9.50 44.5 208.5
273.1 241.3 9.46
NOTES
240.3 MODEL L (IN/MM)
1 TERMINAL BOX CONNECTOR HOLE 3/4” NPT.
10.96 EN858BA72WL 23.65/600.7
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN. 278.4 EN858BD72WL 26.00/660.4

Part/Model Number

EN858BD72WL EN858BD86WL EN858BA72WL CP858FZ72WLR

Specification Units 038744 038745 080070 038980


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS
Horsepower - 10.0 10.0 7.5 10.0
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Voltage AC 230/460 575 230/460 230/460
Motor Nameplate Amps Amps (A) 24/12 9.6 18.6/9.3 24/12
Max. Blower Amps Amps (A) 30/15 11.6 26/13 30/15
Locked Rotor Amps Amps (A) 234/117 93 126/63 234/117
Service Factor - 2/1 1 1/1 2/1
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 338 338 326 338
Shipping Weight
Kg 153.3 153.3 147.9 153.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 31
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 858 & CP 858
7.5 / 10.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 120 IWG
• Maximum vacuum: 95 IWG
• Standard motor: 10 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
EN858D72WL EN858D72WL
80 200 80 200
Inches of Water

EN858BA72WL
Inches of Water

EN858BA72WL
mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 32
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 909 & CP 909
10.0 / 15.0 HP Sealed Regenerative w/Explosion-Proof Motor
L

24.73
628.1
7.23 15.99 8.34
1.37
185.7 403.1 34.8 211.8
4 - 8 NPSC
FEMALE THREAD
BOTH PORTS
IN OUT

ROTATION DIRECTION

231.9
9.13
657.9
25.9

20.25
514.4

EN909BG72WL - 038629

266.7
10.5

3.88
111
8.46
11.6 9.50 3.00 SEE NOTE
IN 1 214.9
352.0 241.3 64.3
MM 8.5
9.06 15.50 .75 X 2.00 SLOT 215.9
275.8 369.8 (4) PLACES
10.75
NOTES MODEL L(IN/MM)
1 TERMINAL BOX CONNECTOR HOLE 1 1/4” NPT FEMALE THREAD. 273.1
EN909BG72WL 30.17/766.3
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. EN909DB72WL 23.66/601.0
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN909BG72WL EN909BG86WL EN909BD72WL CP909GA72WLR

Specification Units 081741 081736 081743 038982


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS
Horsepower - 15 15 10 15
Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Voltage AC 230/460 575 230/460 230/460
Motor Nameplate Amps Amps (A) 36/18 14.4 24/12 36/18
Max. Blower Amps Amps (A) 48/24 18 32/16 48/24
Locked Rotor Amps Amps (A) 240/120 100 234/117 240/120
Service Factor - 2/2 2 2/1 2/2
Starter Size - 1.0 1.0 1.0 1.0
Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
XP Motor Class - Group - I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 524 524 504 524
Shipping Weight
Kg 237.7 237.7 228.6 237.7

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
D 33
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 909 & CP 909
10.0 / 15.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 140 IWG


• Maximum vacuum: 112 IWG
• Standard motor: 15 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 102 204 306 408 510 612 714 816 918 1020 1122 0 102 204 306 408 510 612 714 816 918 1020 1122
150 373 150 373
Legend Legend
125 Pressure: 311 125 Pressure: 311
Suction: Suction:
EN909BG72WL EN909BG72WL
100 249 100 249
Inches of Water

EN909BD72WL EN909BD72WL
Inches of Water

mbar

mbar
75 187 75 187

50 124 50 124

25 62 25 62

0 0 0 0
0 60 120 180 240 300 360 420 480 540 600 660 0 60 120 180 240 300 360 420 480 540 600 660

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 34
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 979 & CP 979
20.0 HP Sealed Regenerative w/Explosion-Proof Motor
19.25
1.50 DIA. (38.1) 489.0 9.75
LIFTING LUG 247.7
OUT IN
4" NPSC
PORTS

ROTATION
DIRECTION

25.32
643.1
21.77
553.0
311.2
12.25
1.

10.37
263.4 5.69
2.47
62.7

1.91 2.00 114.5 11.38

0.76
19.3
48.5 50.8
289.1
8.75
222.3 11.11
IN 282.2
9.00
MM
228.6 13.06
31.25
NOTES 793.8 331.7
1 TERMINAL BOX CONNECTOR HOLE 1 1/4” NPT FEMALE THREAD.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN979BK72WL EN979BK86WL CP979GB72WLR

Specification Units 080724 082277 081778


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS
Horsepower - 20 20 20
Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz
Motor Nameplate Amps AC 230/460 575 230/460
Max. Blower Amps Amps (A) 46/23 18.4 46/23
Locked Rotor Amps Amps (A) 60/30 24 60/30
Service Factor Amps (A) 334/167 118 334/167
Starter Size - 3/2 2 3/2
Thermal Protection - 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 533 533 533
Shipping Weight
Kg 241.8 241.8 241.8

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 35
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 979 & CP 979
20.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 90 IWG


• Maximum vacuum: 90 IWG
• Standard motor: 20 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870 0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
EN979 EN979
80 200 80 200
Inches of Water
Inches of Water

mbar

mbar
60 150 60 150

40 100 40 100

20 50 20 50

0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 0 100 200 300 400 500 600 700 800 900 1000 1100

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 36
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 14 & CP 14
20.0 / 30.0 HP Sealed Regenerative w/Explosion-Proof Motor
17.57
30.14 446.19
765.56 9.64
8.61 244.86
218.69 4-8 NPSC
OUT IN
FEMALE THREAD
BOTH PORTS
(CAST IRON)

ROTATION
DIRECTION
786.38

617.22
30.96

24.3

327.15
12.88
15.32
29.74

389.13
1.17

23.32
592.39

3.00 9.65
76.12 245.03
11.00 14.32
IN 10.25 279.40 363.73
16.99
MM 260.32 431.64 SLOTS
.75 x 2.00 12.76
L (19.1 x 50.8) 324.10 MODEL LENGTH (IN/MM)
NOTES
1 TERMINAL BOX CONNECTOR HOLE 1 1/4” NPT FEMALE THREAD. 4X PLACES EN14BK72MWL 32.12/815.9
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. EN14DX72MWL 31.185/792.1
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

EN14BK72MWL EN14DX72MWL EN14DX86MWL CP14GB72MWLR CP14GC72MWLR

Specification Units 081485 081486 081487 TBD 081491


Motor Enclosure - Shaft Mtl. - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS
Horsepower - 20 30 30 20 30
Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz
Motor Nameplate Amps AC 230/460 200-230/460 575 230/460 200-230/460
Max. Blower Amps Amps (A) 46/23 75-66/33 26.5 46/23 75-66/33
Locked Rotor Amps Amps (A) 60/30 82/41 33 60/30 82/41
Service Factor Amps (A) 294/147 448/224 226 294/147 448/224
Starter Size - 3//2 3/3 3 3/2 3/3
Thermal Protection - 1.0 1.0 1.0 1.0 1.0
XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G I-D, II-F&G
Lbs 601 737 737 601 737
Shipping Weight
Kg 272.6 334.3 334.3 272.6 334.3

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 3 phase motors are factory tested and
certified to operate on both: 208-230/415-460 VAC-3 ph-60 Hz and 190-208/380-415 VAC-3 ph-50 Hz. Our dual voltage 1 phase motors are factory tested and
certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage fluctuation.
Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 37
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Environmental / Chemical Processing Blowers
EN 14 & CP 14
20.0 / 30.0 HP Sealed Regenerative w/Explosion-Proof Motor

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 144 IWG
• Maximum vacuum: 115 IWG
• Standard motor: 30 HP, explosion-proof
• Cast aluminum blower housing, impeller , cover & manifold; cast iron

• UL & CSA approved motor with permanently sealed ball bearings for
explosive gas atmospheres Class I Group D minimum
• Sealed blower assembly
• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves



• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870 0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
180 450 180 450
Legend Legend
150 Pressure: 375 150 Pressure: 375
Suction: Suction:
EN14DX72MWL EN14DX72MWL
120 EN14BK72MWL 300 120 EN14BK72MWL 300
Inches of Water

Inches of Water
mbar

mbar
90 225 90 225

60 150 60 150

30 75 30 75

0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 0 100 200 300 400 500 600 700 800 900 1000 1100

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding

Motor Winding
Temp Rise °C

Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C

Temp Rise °C
Blower Air

Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 D 38
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motor-less) Blowers
AMETEK Technical & Industrial Products’ ROTRON brand has long been a world leader in regen-
erative blower technologies, bringing regenerative advantages to a new level, providing quiet,
maintenance-free, oil-free operation.

Our industrial (_RD) Remote Drive Blowers are motorless models built with DR/EN/CP/SL blower
features and include:

Rugged cast-iron arbor and bearing suspension system


Oversized shaft to withstand heavy-duty side loads
Precision balanced impellers for low vibration operation
High speed versions built with heat treated impellers available.

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Remote Drive (Motorless) Blowers
MF573RD

A ROTATION

AIR IN E

AIR OUT

D G
NOTES
1 CONTACT FACTORY FOR PULLEY OPTIONS.
2 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G


3.63 1.25 6.58 1.75 1.75 1.75 3.56
MF573RD 026940
92.2 31.8 167.1 44.5 44.5 44.5 90.4

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
60 150 60 150

50 125 50 125
14,000 RPM 14,000 RPM
Inches of Water
Inches of Water

40 100 40 100
12,000 RPM 12,000 RPM
mbar

mbar
30 75 30 75
10,000 RPM 10,000 RPM
20 50 20 50

10 25 10 25

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


.8 .8
14,000 RPM 14,000 RPM
Horsepower
Horsepower

12,000 RPM 12,000 RPM


Input
Input

.4 .4
10,000 RPM 10,000 RPM
0 0

Do not exceed maximum speed shown on each graph. Do not exceed maximum speed shown on each graph.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
SL2RD

B
Q
K 4 MTG HOLES
J E L

G
ROTATION
N IN OUT

P
S FLAT

D
4 MTG HOLES H 1/4-20 UNC - 2B X 44
(SAME AS OPPOSITE SIDE) 4 HOLES EQ SPACED ON 4.43 DIA
A
NOTES R
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G H J K L M N P Q R S T


7.33 5.88 9.92 1.45 1.00 .500 1.75 .25 1.75 1.41 2.62 1.75 4.96 3.31 3.00 9.92 .473 1.00
SL2RD 026125
186.2 149.4 252 36.8 25.4 12.7 44.5 6.4 44.5 35.8 66.5 44.5 126 84.1 76.2 252 12 25.4

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
120 300 120 150

100 250 100 ˚C 125


75 C
50˚
˚C

25˚C
00

Inches of Water
Inches of Water

80 200 80 100
C
T1


RA

˚C

10

˚C
75

50
AT
AI

mbar

mbar
60 ˚C 60 150 60 75
25
R

00 600
AI

55 RP 550 0R
50 00 M 0R PM
450 00 RP 500 PM
40
40 R M 100 40 450 0R 50
0R
3500
RPM 00 RPM PM PM 400
0
0R
PM
PM
3000 35 R P
20 2500
RPM
50 20 3000 00 RPM M 25
RPM 2500 R RPM
PM
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


2.0 2.0
Horsepower
Horsepower

1.5 1.5
Input
Input

1.0 6000 RPM 1.0 6000 RPM


5500 RPM 5500 RPM
0.5 5000 RPM 0.5
4500 RPM 4500 RPM 5000 RPM
3500 RPM 4000 RPM 3000 RPM 3500 RPM
4000 RPM
0 2500 RPM 3000 RPM 0 2500 RPM
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 404RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


5.60 11.5 12.2 2.00 .188 .875 1.56 4.00 .50 5.00 5.12 1.50 6.17 4.5 4.00 11.54
DR404RDNT 036439
142.2 292.1 309.9 50.8 4.8 22.2 39.6 101.6 12.7 127 130 38.1 156.7 114.3 101.6 293.1
12.76 11.50 12.2 2.00 .188 .875 1.56 4.00 .50 5.00 5.12 1.50 6.17 4.5 4.00 11.54
EN404RDML 038334
324.1 292.1 309.9 50.8 4.8 22.2 39.6 101.6 12.7 127 130 38.1 156.7 114.3 101.6 293.1

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
˚C
00 C
T1 C 00˚
100
R
A 75˚ 250 100
AT
1 250
AI AIR
50˚C C
75˚
Inches of Water
Inches of Water

80 200 80 200
50˚C 55
55

65

00
mbar

mbar
00

60 150 60 25˚C 150


00

RP
65

25˚C
RP

M
RP

00
M

RP
M

40 100 40 45 100
00
M
45

35 RP
250 00
00

25
35

175 M
20 00 50 20 175 0R RP 50
00

0R
RP

RP 0R P
PM PM M M
RP

M
M
M

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


7.0 7.0
Horsepower
Horsepower

4.0 4.0
2.0 2.0
Input
Input

0.8 0.8
6500
0.4 0.4 6500
3500 4500 5500 4500 5500
0.1 2500 0.1 2500 3500
1750 1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 505RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


5.68 11.82 14.45 2.00 .188 .875 1.56 4.00 .50 5.31 4.75 1.50 7.31 5.33 4.00 13.53
DR505RDNT 036437
144.3 300.2 367 50.8 4.8 22.2 39.6 101.6 12.7 134.9 120.7 38.1 185.7 135.4 101.6 343.7
14.58 11.82 14.45 2.00 .188 .875 1.56 4.00 .50 5.31 4.75 1.50 7.31 5.33 4.00 13.53
EN505RDML 038336
370.3 300.2 367 50.8 4.8 22.2 39.6 101.6 12.7 134.9 120.7 38.1 185.7 135.4 101.6 343.7

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 42 85 127 170 212 255 297 340 382 425 467 0 42 85 127 170 212 255 297 340 382 425 467
180 448 180 448

150 AIR AT 100˚C 373 150 373


AIR AT 100˚C
Inches of Water
Inches of Water

120 299 120 299


75˚C
55

75˚C
65
00

mbar

mbar
00

90 224 90 224
RP

RP
M

50˚C
M

60 50˚C 149 60 55 149


00 65
35 RP 00
25 00 250 M RP
45

30 175 00 RP 75 30 1750 0R 35 M 75
00

RP RPM PM 00 45
0R M 00
RP 25˚C
RP

PM M RP
25˚C M M
M

0 0 0 0
0 25 50 75 100 125 150 175 200 225 250 275 0 25 50 75 100 125 150 175 200 225 250 275

Air Flow Rate - SCFM Air Flow Rate - SCFM


10 10
Horsepower
Horsepower

4.0 4.0 6000


2.0 5500 6000 2.0 5500
Input
Input

0.8 4500 0.8 4500


3500 3500
0.4 2500 0.4 2500
.15 .15
1750 1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E4
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 513RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


6.07 13.66 16.12 2.00 .188 .875 1.56 .516 4.00 5.29 4.75 1.50 7.31 6.45 4.00 14.21
DR513RDNT 038076
154.2 347 409.4 50.8 4.8 22.2 39.6 13.1 101.6 134.4 120.7 38.1 185.7 163.8 101.6 360.9
11.90 13.66 16.12 2.00 .188 .875 1.56 .516 4.00 5.29 4.75 1.50 7.31 6.45 4.00 14.21
EN513RDL 038341
302.3 347 409.4 50.8 4.8 22.2 39.6 13.1 101.6 134.4 120.7 38.1 185.7 163.8 101.6 360.9

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
180 448 180 448

150 373 150 100˚C 373


100˚C
75˚C
75˚C
Inches of Water
Inches of Water

120 299 120 299


50˚C 50˚C
mbar

mbar
90 224 90 224
25˚C
25˚C
60 150 60 150
60
45

600

35
45
35

550

00
00
55
00

00
00

25
0R
25

0R

30 75 30 00 R 75
00

RP
RP
RP
RP

PM
00

RP
RP
PM

M
PM

M
M
R

M
M
PM

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


8 8
Horsepower
Horsepower

Input
Input

4 4
6000 6000
5500
5500 4500
0 4500 0 3500
2500 3500 2500
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 523RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


7.96 13.8 16.12 2.00 .188 .875 1.56 .516 4.00 7.18 4.75 1.50 7.31 6.45 4.00 14.21
DR523RDNT 037223
202.2 350.5 409.4 50.8 4.8 22.2 39.6 13.1 101.6 182.4 120.7 38.1 185.7 163.8 101.6 360.9
13.8 15.55 16.12 2.00 .188 .875 1.56 .516 4.00 7.18 4.75 1.50 7.31 6.45 4.00 14.21
EN523RDL 038342
350.5 395 409.4 50.8 4.8 22.2 39.6 13.1 101.6 182.4 120.7 38.1 185.7 163.8 101.6 360.9

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 26 51 76 102 127 153 178 204 230 255 280 0 26 51 76 102 127 153 178 204 229 255 280
240 598 240 598

200 498 200 498


AIR AT 100˚C
Inches of Water
Inches of Water

160 75˚C 398 160 398


AIR AT 50˚C
50˚C
mbar

mbar
120 298 120 298
250
0R 35
60

PM 00 45
55

00

80 199 80 RP 00 199
00

25˚C 250 M RP
RP

0R M
RP

PM
M
60
55
45

M
35

40 100 40 25˚C 100


00
00
00
00

175
RP
RP
R

0R 1750
RP

PM

PM RPM
M

M
M

0 0 0 0
0 15 30 45 60 75 90 105 120 135 150 165 0 15 30 45 60 75 90 105 120 135 150 165

Air Flow Rate - SCFM Air Flow Rate - SCFM


16 16
Horsepower
Horsepower

Input
Input

8 8 6000
6000
5500
0 5500 4500
2500 3500 4500 0 2500 3500
1750 1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 6RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


5.85 15.00 16.34 3.62 .25 1.00 1.75 .505 4.50 6.10 6.50 2.00 8.19 5.6 4.50 16.34
DR6RDNT 036185
148.6 381 415 91.9 6.4 25.4 44.5 12.8 114.3 154.9 165.1 50.8 208 142.2 114.3 415
5.85 15.00 16.34 3.62 .25 1.00 1.75 .505 4.50 6.10 6.50 2.00 8.19 5.6 4.50 16.34
EN6RDL* 038343
148.6 381 415 91.9 6.4 25.4 44.5 12.8 114.3 154.9 165.1 50.8 208 142.2 114.3 415

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 51 102 153 204 255 306 357 408 459 510 561 0 51 102 153 204 255 306 357 408 459 510 561
180 448 180 448

150 0˚C 75˚C 374 150 374


10
AT
R
AI
Inches of Water

AIR AT 100˚C
Inches of Water

120 299 120 299


50˚C 75˚C
mbar

mbar
90 224 90 224
45
00 50˚C
55

R
00

60 PM 150 60 35 45 55 150
RP

00 00 00
250 RP RP RP
M

25 35 0R M M M
30 75 30 PM 75
175 00R 00 25˚C 25˚C
0R PM RP
PM M 1750
0 0 0 RPM 0
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330

Air Flow Rate - SCFM Air Flow Rate - SCFM


20 20
Horsepower
Horsepower

Input
Input

10 10
5500 5500
3500 4500 3500 4500
0 0
1750 2500 1750 2500
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

* Dual mufflers provided in place of muffler tower.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E7
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 656RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


7.35 12.44 15.17 2.00 .188 .875 1.56 .50 4.00 5.83 4.92 2.00 7.46 5.51 4.00 15.42
DR656RDNT 080610
186.7 316.0 385.3 50.8 4.8 22.2 39.6 12.7 101.6 148.1 125 50.8 189.5 140 101.6 391.7
15.12 14.6 15.17 2.00 .188 .875 1.56 .50 4.00 5.83 4.92 2.00 7.46 5.51 4.00 15.42
EN656RDL 080061
385 370.8 385.3 50.8 4.8 22.2 39.6 12.7 101.6 148.1 125 50.8 189.5 140 101.6 391.7

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
180 448 180 448
100˚C
150 374 150 100˚C 374
50˚C
Inches of Water
Inches of Water

120 299 120 299


50˚C
mbar

mbar
90 224 90 224
25˚C
60

60 250 150 60 150


0R
00
600

PM
55
55

45

35
RP
45

35 00
00

25
0R

00
00

0 00
00

RP
M

30 0 75 30 75
R

RP
RP

M
PM

RP
PM

PM

17
RP

M
50 M
M

1750
M

RPM RPM
0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


30 30
Horsepower
Horsepower

Input
Input

15 15
6000 6000
4500 5500 4500 5500
0 2500 3500 0 2500 3500
1750 1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
E8
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 757RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


6.67 15.06 17.25 3.62 .25 1.00 1.75 .505 4.50 6.19 6.44 2.50 9.22 6.40 4.50 16.11
DR757RDNT 081847
169.4 382.5 438.2 91.9 6.4 25.4 44.5 12.8 114.3 157.2 163.6 63.5 234.2 162.6 114.3 409.2
15.06 20.23 17.25 3.62 .25 1.00 1.75 4.50 .505 6.19 6.44 2.50 9.22 6.40 4.50 16.11
EN757RDML 081848
382.5 513.8 438.2 91.9 6.4 25.4 44.5 114.3 12.8 157.2 163.6 63.5 234.2 162.6 114.3 409.2

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
180 448 180 AIR AT 100˚C 448
AIR AT 100˚C

150 374 150 374


Inches of Water
Inches of Water

120 299 120 75˚C 299


75˚C
mbar

mbar
90 224 90 224

60 150 60 50˚C 150


55

55
00

25 50˚C 45
45
35

00 25 35 00 00
RP
00

00

30 RP 75 30 00 00 RP RP 75
RP RP
M
R

RP

M M M
PM

M M
M

0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


40 40
Horsepower
Horsepower

Input
Input

20 20
5500
4500 5500
0 3500 4500 0
2500 2500 3500
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
E9
www.ametekdfs.com
Remote Drive (Motorless) Blowers
DR/EN/CP 858RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


8.51 19.30 20.86 3.50 .313 1.38 2.00 .641 5.00 9.49 7.09 2.50 11.56 8.16 5.00 18.6
DR858RDNT 036413
216.2 490.2 529.8 88.9 8 35.1 50.8 16.3 127 241 180.1 63.5 293.6 207.3 127 472.4
19.30 22.22 20.86 3.50 .313 1.38 2.00 .641 5.00 9.49 7.09 2.50 11.56 8.16 5.00 18.6
EN858RDL 038746
490.2 564.4 529.8 88.9 8 35.1 50.8 16.3 127 241 180.1 63.5 293.6 207.3 127 472.4

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 68 136 204 272 340 408 476 544 612 680 748 0 68 136 204 272 340 408 476 544 612 680 748
180 448 180 448
AIR AT 100˚C

150 75˚C 374 150 374


AIR AT 100˚C
Inches of Water
Inches of Water

120 299 120 75˚C 299


50˚C
mbar

mbar
40

90 224 90 224
00

50˚C
RP

35
25˚C 150 00 40
M

60 60 RP 0 150
M 0R
35 PM
25 00 250
30 175 00 75 30 0 RP 75
0R RP R 1750 M
PM M PM RPM 25˚C
0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


20 20
Horsepower
Horsepower

Input
Input

10 10
4000
4000
0 0
1750 2500 3500 1750 2500 3500
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E 10
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 909RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


8.53 22.8 23.22 3.50 .500 1.375 2.00 .765 5.00 9.70 8.34 3.01 12.97 9.02 5.00 19.8
DR909RDNT 081962
216.7 581 589.8 88.9 12.7 34.9 50.8 19.4 127 246.4 211.8 76.5 329.4 229.1 127 502.9
22.8 24.51 23.22 3.50 .500 1.375 2.00 .765 5.00 9.70 8.34 4.00 12.97 9.02 5.00 19.8
EN909RDL 081742
579.1 622.6 589.8 88.9 12.7 34.9 50.8 19.4 127 246.4 211.8 101.6 329.4 229.1 127 502.9

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 136 272 408 544 680 816 952 1088 1224 1360 1496 0 136 272 408 544 680 816 952 1088 1224 1360 1496
180 448 180 448

150 AIR AT 100˚C 374 150 374

75˚C
Inches of Water
Inches of Water

120 299 120 AIR AT 100˚C 299


75˚C
mbar

mbar
90 224 90 224
50˚C
50˚C
60 150 60 150
45
35 00
45
35

25 00 RP
00
00

30 00 75 30 250 RP M 75
175 1750 M
RP

RP 0R
RP

0R RPM PM
PM M
M

0 0 0 0
0 80 160 240 320 400 480 560 640 720 800 880 0 80 160 240 320 400 480 560 640 720 800 880

Air Flow Rate - SCFM Air Flow Rate - SCFM


40 40
Horsepower
Horsepower

Input
Input

20 20

3500 4500 3500 4500


0 2500 0
1750 1750 2500
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E 11
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 979RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


10.5 23.5 19.78 3.00 .50 1.88 2.75 .765 6.75 11.7 9.76 4.00 10.15 6.63 7.55 19.25
DR979RDNT 080760
266.7 596.9 502.4 76.2 12.7 47.8 69.9 19.4 171.5 297.2 247.9 101.6 257.8 168.4 191.8 489
23.5 25.17 19.78 3.00 .50 1.88 2.75 .765 6.75 11.7 9.76 4.00 10.15 6.63 7.55 19.25
EN979RDL 080761
596.9 639.3 502.4 76.2 12.7 47.8 69.9 19.4 171.5 297.2 247.9 101.6 257.8 168.4 191.8 489

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243 0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
180 448 180 448
AIR AT 100˚C
150 374 150 AIR AT 100˚C 374
75˚C
75˚C
Inches of Water
Inches of Water

120 299 120 299


50˚C
mbar

mbar
90 224 90 224
50˚C

60 150 60 150

35 37 37
1750 R 250 00 00 00
30 PM RP 75 30 250 350 RP 75
0 RP RP 1750 R 0 RP 0R M
M M M PM M PM
0 0 0 0
0 120 240 360 480 600 720 840 960 1080 1200 1320 0 120 240 360 480 600 720 840 960 1080 1200 1320

Air Flow Rate - SCFM Air Flow Rate - SCFM


40 40
Horsepower
Horsepower

Input
Input

20 20
3700 3700
3500
0 0 2500 3500
1750 2500 1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E 12
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Remote Drive (Motorless) Blowers
DR/EN/CP 1233RD

N +/- .25

ROTATION

2.36
59.9
M +/- .25
B

(2X) H (4X) F 0.39


10
L +/- .12

(2X) T (4X) R

DETAIL AA SEE IN OUT


DETAIL AA K +/- .12 Q +/- .12
C +/- .06 D E
A
NOTES G +/- .25
(2X) P
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD J +/- .12
NPSC THD
DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.
3 FILTER #515256 1PIECE

Specification

Model Number Part Number A B C D E F G J H K L M N P Q R T


14.96 1.50 2.36 9.45 12.80 .551 28.22 16.34 0.43 3.15 11.81 22.05 20.47 4.00 6.69 0.93 1.37
DR1233RD 081853
380 38.1 59.9 240 325.1 14 716.8 415 10.9 80 300 560.1 519.9 101.6 169.9 23.6 34.8
14.96 1.50 2.36 9.45 12.80 .551 28.22 16.34 0.43 3.15 11.81 22.05 20.47 4.00 6.89 0.93 1.37
EN1233RDL 081854
380 38.1 59.9 240 325.1 14 716.8 415 10.9 80 300 560.1 519.9 101.6 175 23.6 34.8

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
136 204 272 340 406 476 544 612 680 748 846 884 0 68 136 204 272 340 408 476 544 612 680 748
300 598 240 598

250 AIR AT 100˚C 498 200 AIR AT 100˚C 498


Inches of Water
Inches of Water

200 398 160 398


75˚C
mbar

mbar
150 298 120 298
75˚C
50˚C
100 50˚C 199 80 199
28

40

45
35
50

43

40 00
00
00

00
00

35 RP
RP

50 100 40 28 00 RP 100
R

50 M
RP

RP
M

RP
PM

RP M
M

M M
M

0 0 0 0
80 120 160 200 240 280 320 360 400 440 480 520 0 40 80 120 160 200 240 280 320 360 400 440

Air Flow Rate - SCFM Air Flow Rate - SCFM


25 25
Horsepower
Horsepower

Input
Input

15 15
4300 4500
4000 4000
5 3500 5 3500
2850 2850
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS E 13
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Remote Drive (Motorless) Blowers
DR/EN/CP 14RD

B B

A A M NPSC L

N ROTATION
OUT IN
E KEY D E KEY P
D
F F

C C

G G Q

H DIA. TYP H DIA. TYP


J TYP J TYP
K 4 MTG HOLES K 4 MTG HOLES

DR MODELS EN MODELS DR/EN MODELS


NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Specification IN/MM

Model Number Part Number A B C D E F G J H K L M N P Q R


9.87 22.24 26.54 4.00 .50 1.875 2.75 .765 6.75 10.24 9.69 4.00 15.50 11.41 7.55 23.32
DR14RDNT 081475
250.7 564.9 674.1 101.6 12.7 47.6 69.9 19.4 171.5 260.1 246.1 101.6 393.7 289.8 191.8 592.3
22.24 30.14 26.54 4.00 .50 1.875 2.75 .765 6.75 10.24 9.69 4.00 15.50 11.41 7.55 23.32
EN14RDL 081488
564.9 765.6 674.1 101.6 12.7 47.6 69.9 19.4 171.5 260.1 246.1 101.6 393.7 289.8 191.8 592.3

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 136 272 408 544 680 816 952 1088 1224 1360 1496 0 136 272 408 544 680 816 952 1088 1224 1360 1496
180 448 180 448
AIR AT 100˚C
150 374 150 374
AIR AT 100˚C
75˚C 75˚C
Inches of Water
Inches of Water

120 299 120 299


50˚C
50˚C
mbar

mbar
90 224 90 224
37

60 150 60 37 150
00
00

35
35

RP
25

RP

250 00
00

17 M
00

50 175 0R RP
M

30 75 30 0R 75
RP

PM M
R

RP PM
PM

M
M

0 0 0 0
0 80 160 240 320 400 480 560 640 720 800 880 0 80 160 240 320 400 480 560 640 720 800 880

Air Flow Rate - SCFM Air Flow Rate - SCFM


60 60
Horsepower
Horsepower

Input
Input

30 30
3700 3700
3500 2500 3500
0 2500 0 1750
1750
Do not exceed maximum speed shown on each graph or 100°C. Do not exceed maximum speed shown on each graph or 100°C.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 E 14
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Regenerative Blowers
Specialty blowers for Commercial Spa, High Temperature, Natural Gas, and Gasoline Vapor
Recovery applications.

Our industrial NC (NautilairTM Centraxial) blowers include:


Fiberglass or aluminum housing
Aluminum impellers
Permanently sealed bearings for 50,000 hours life

Our instrument grade and variable flow SE (MinispiralTM Regenerative) blowers include:
AC and DC versions available for world voltages and maximum flow variability
Glass filled molded phenolic impeller; aluminum and phenolic case
30,000 hour bearing life
Small size and lightweight construction
Quiet to NC-47 office equipment standards

Our instrument grade SL (Spiral Regenerative) blowers include:


Rugged diecast aluminum housing, endbells, and impellers
Compact size with encased muffler for maximum noise reduction
Low amp draw with highly efficient motor
Permanently sealed bearings for 40,000 hours life
Hermetically sealed models designed for glovebox use

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
4.11 DIA.
104.4
1 1.65
41.91

.75 O.D. TYP.


DIA.
Ø2.24

.25 REF.
56.9

14.22

19.05

6.35
.56
OUT

4.16 REF.

105.66
39.12
1.54
2

53.34
2.10
IN

.44 REF. TYP.

.67

.09 TYP.
11.18

0.32 .53
17.02

2.29
8.13 13.46
1.75 2.03
1.13 .68 MAX. 44.45 51.56
IN 28.7 17.27
MM 3.50
1.80 REF. 88.9 .212 DIA.
45.72 5.38
NOTES 4.06 (2) MTG. HOLES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 103.12
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SE2B21 SE62B21 SE2B21A

Specification Units 081901 037395 080694


Phase - Frequency - Single-50/60 Hz - Single-50/60 Hz
Voltage AC 110/115 24 110/115
RPM RPM 2850/3400 2850/3400 2850/3400
Insulation Class - B B B
Full - Load Amps Amps (A) .17/.14 - .17/.14
Locked Rotor Amps Amps (A) .17/.15 - .17/.15
Lbs 1.9 1.9 1.9
Shipping Weight
Kg 0.9 0.9 0.9

1 Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors
or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or
ambient temperatures above 40°C.
2 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or
ambient temperature reaches the maximum operating temperature.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 3.5 IWG


• Maximum vacuum: 3.5 IWG
• Maximum ambient: 40°C

• Shaded pole motor with ball bearings

• B10 bearing life: 30,000 hours


• Weight: 1.1 lb (0.5 kg)
• Envelope size: 4.18 x 1.83 inches (106.2 x 46.5 mm)

OPTIONS
• Sealed units
• International voltage and frequency (Hz)

50 60
NC
3 FEET (0.91 METERS) FROM NOISE SOURCE

50
EQUIVALENT SOUND PRESSURE LEVEL –
db (re 0.0002 microbar)

SOUND POWER LEVEL —


db (re 10 -12 Watts)

40 50
40

30 40
30

20 30
63 125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTERFREQUENCY Hz

Blower Performance at Standard Conditions


60 Hz 50 Hz

Air Flow Rate - m3/hour Air Flow Rate - m3/hour


0 1.7 3.4 5.1 6.8 0 1.7 3.4 5.1 6.8
4.0 10.0 4.0 10.0

Legend Legend
Pressure: Pressure:
Suction: Suction:
3.0 Minispiral 7.5 3.0 Minispiral 7.5
Inches of Water

Inches of Water
mbar

mbar

2.0 5.0 2.0 5.0

1.0 2.5 1.0 2.5

0 0 0 0
0 1.0 2.0 3.0 4.0 0 1.0 2.0 3.0 4.0

Air Flow Rate - SCFM Air Flow Rate - SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower

4.11 DIA.
104.4
2 leads. 20 ga. 1.65
TFE covered. 41.91
UL style 1180
(12" long, stripped 50")

DIA.
.75 O.D. TYP.

Ø2.24

.25 REF.
56.9
14.22

19.05

6.35
OUT
.56

4.16 REF.
105.66
39.12
1.54
2

53.34
IN

2.10
.44 REF. TYP.

0.32 .53 .67


.09 TYP.

8.13 13.46 17.02


2.29
11.18

1.75 2.03
1.13 .68 MAX. 44.45 51.56
28.7 17.27 3.50
IN 1.80 REF. 88.9 .212 DIA.
MM 45.72 5.38
4.06 (2) MTG. HOLES
103.12
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SE12V21 SE24V21

Specification Units 037433 037434


Voltage Range VDC 9-15 24-32
RPM RPM 3600-6000 5500-6800
Insulation Class - B B
Full - Load Amps Amps (A) 0.50-1.0 0.6-0.9
Lbs 0.86 0.86
Weight
Kg 0.4 0.4

WARNING– ON MDCMODEL:EXCEEDING
1.0 AMPMAY DAMAGECIRCUIT
BOARD.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 7.0/10.3 IWG (15/32 volts)


• Maximum vacuum: 7.0/10.3 IWG (15/32 volts)
• Maximum ambient: 40°C

& impeller
• Shaded pole motor with ball bearings

• B10 bearing life: 20,000 - 30,000 hours


• Weight: 0.86 lbs (0.39 kg)
• Envelope size: 4.18 x 1.83 inches (106.2 x 46.5 mm)

OPTIONS
• Sealed blowers for contamination control
• Electronic speed control

50 60
NC
3 FEET (0.91 METERS) FROM NOISE SOURCE

50
db (re 0.0002 microbar)

Watts)

40 50
40
-12
db (re 10

30 40
30

20 30
63 125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTERFREQUENCY Hz

Blower Performance at Standard Conditions


12 V-MDC 24 V-MDC

Air Flow Rate - m3/hour Air Flow Rate - m3/hour

11.0 11.0
10.0 Legend 10.0 Legend
Pressure: Pressure:
9.0 Suction: 9.0 Suction:
Minispiral MDC Minispiral MDC
8.0 8.0
Inches of Water

Inches of Water

7.0 7.0
32 V-MDC
mbar

mbar
6.0 6.0
15 V-MDC 26 V-MDC
5.0 5.0
24 V-MDC
4.0 12 V-MDC 4.0
3.0 3.0
2.0 9 V-MDC 2.0
1.0 1.0

0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Air Flow Rate - SCFM Air Flow Rate - SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F4
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral 12/24V HDC
Variable Flow Regenerative Blower

20 GA. TFE COVERED


1.16 UL STYLE 1180
29.5 14" LONG, STRIPPED 1/2"
1.19
30.2 Ø 4.20
0.66 106.7
16.8

0.25
6.4
0.63
16.0

2.17
55.2
46.5
Ø 1.83

2.26
57.4

53.6
2.11
47.2
1.86

106.9
4.21
0.57 OD

1.14
29.0 0.67
14.5

0.54 17.0
0.92 13.7 1.65
0.57
14.5
0.75 OD

23.4 41.9
1.99 3.50
0.83
19.1

88.9
0.44
11.2

21.1 50.5 4.07


IN 2.82 103.4
MM BOTH PORTS
71.6
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SE12RE21 SE24RE21

Specification Units 081548 080847


Voltage Range VDC 7.5-15 24-32
RPM RPM 4400-8750 4400-8750
Insulation Class - B B
Full - Load Amps Amps (A) 1.2-2.5 1.2-1.6
Lbs 1.0 1.0
Weight
Kg 0.5 0.5

WARNING – ON HDCMODEL:MOTORISNOT POLARITY


PROTECTED
. CHECKPOLARITY
CAREFULL
Y BEFORE
ENERGIZING
BLOWER.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral 12/24V HDC
Variable Flow Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant
• 12 VDC operation: 7.5-15 VDC
• 24 VDC operation: 15-32 VDC

• Maximum pressure: 20.7 IWG (15)


• Maximum vacuum: 20.7 IWG (15)
• Maximum ambient: 40°C

& impeller
• Brushless DC motor with integrated control electronics

• Stainless steel ball bearings permanently lubricated for B10 bearing life:
20,000 - 30,000 hours
• Weight: 1.9 lbs (0.86 kg)
• Envelope size: 4.18 x 1.83 inches (106.2 x 46.5 mm)

OPTIONS
• Sealed blowers for contamination control
• Electronic speed control
• Low voltage option
• International voltage and frequency (Hz)
50 60
NC
3 FEET (0.91 METERS) FROM NOISE SOURCE

50
EQUIVALENT SOUND PRESSURE LEVEL
db (re 0.0002 microbar)

db (re 10 -12 Watts)

40 50
SOUND POWER LEVEL

40

30 40
30

20 30
63 125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTERFREQUENCY Hz

Blower Performance at Standard Conditions


Minispiral HDC

Air Flow Rate - m3/hour


0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3
22 55

20 Legend 50
Pressure:
18 Suction: 45
Minispiral HDC
16 40

14 35
Inches of Water

15 V-HDC
mbar

12 30
12
10 V- 25
HD
C
8 20
9V
-HD
6 7.5 C 15
V-H
DC
4 LOW 10
VOLTAGE
2 OPERATION 5

0 1 2 3 4 5 6 7 8 9
Air Flow Rate - SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral 12V HDC Extra Flow / Extra Wide Fat Boy
Variable Flow Regenerative Blower

20 GA. TFE COVERED


1.30 UL STYLE 1180
33.0 14" LONG, STRIPPED 1/4"
1.19
30.2 Ø 4.11
0.66 104.4
16.8

4.16 REF.
0.25

106.9
6.4
0.63
16.0

2.17
55.2
Ø 1.750
44.4

2.24
56.9

47.0
1.85

2.10
53.3
1.06
0.56 ID

26.9 0.67
14.2

0.53 17.0
0.92 13.5 1.65
0.56
14.2
19.1 TYP.
0.75 OD

23.4 10.7 REF. 41.9


1.92 TYP. 3.50
0.80
88.9
0.42

20.3 48.8 4.06


IN 2.72 103.1
MM BOTH PORTS
69.1
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SE12RE21A

Specification Units 081881


RPM RPM 7397 - 13205
Voltage Range VDC 7.5 - 15
Insulation Class - B
Full - Load Amps Amps (A) 2.7 - 6.2
Lbs 2.5
Weight
Kg 1.1

WARNING – ON HDCMODEL:MOTORISNOT POLARITY


PROTECTED
. CHECKPOLARITY
CAREFULL
Y BEFORE
ENERGIZING
BLOWER.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F7
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Minispiral 12V HDC Extra Flow / Extra Wide Fat Boy
Variable Flow Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 26 IWG (15)


• Maximum vacuum: 26 IWG (15)
• Maximum ambient: 40°C

• Brushless DC motor with integrated control electronics


• Stainless steel ball bearings permanently lubricated for B10 bearing life:
20,000 - 30,000 hours
• Weight: 1.9 lbs (0.86 kg)
• Compact high performance design: 4.18 x 1.83 inches (106.2 x 46.5 mm)

OPTIONS
• Sealed blowers for contamination control
• Electronic speed control
• Low voltage option
• Speed sensing output (FPS)
3 FEET (0.91 METERS) FROM NOISE SOURCE

50 60
NC
EQUIVALENT SOUND PRESSURE LEVEL

50
db (re 0.0002 microbar)

db (re 10 -12 Watts)


SOUND POWER LEVEL

40 50
40

30 40
30

20 30
63 125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY Hz

Blower Performance at Standard Conditions


Minispiral HDC
Air Flow Rate - m3/hour
0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3 17.0 18.7 20.4 22.1
26 65
24 60
Legend
22 Pressure: 55
Suction:
20 Minispiral HDC 50
18 15
V- 45
HD
16 C
40
Inches of Water

12
14 V- 35
HD
mbar

C
12 30
10 25
8 7.5
V-H 20
DC
6 15
4 10
LOW
2 VOLTAGE 5
OPERATION
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13

Air Flow Rate - SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F8
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower

OPTIONAL OUTLET TRIMMER


7.84
199.1
12.17 OPTIONAL INLET TRIMMER 5.87
309.1 149.1

.56 2.92
14.2 74.2
1/2" CONDUIT HOLE (1) EACH END

41.2
1.62
253.2

2.89
73.4
9.97

104.7
4.12

1.75 O.D.
44.5
3.31
84.1
126.2
4.98

OUT IN

1.60 I.D.
40.6
2.63 1.00
66.6 25.4
.25 -20 UNC -2B X .31 DEEP
(4 MOUNTING HOLES EACH END)
IN 3.00 TYP. 1.20 1.75
MM 76.2 30.5 44.5

NOTES 2.29
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING. 58.2
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SL2P2 SL2P52 SL2P90

Specification Units 036000 036013 036018


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS ODP-CS
Horsepower - .5 .5 .5
Voltage AC 115 208-230 380/460
Phase - Frequency - Single-50/60 Hz Single 60 Hz Three-50/60 Hz
Insulation Class - B B B
Full - Load Amps Amps (A) 2.45/3.60 .95/1.54 .34/.41
Service Factor - 1.0 1.0 1.0
Locked Rotor Amps NEMA Amps (A) 10.0 4.3 1.9
Starter Size - 00/00 00/00 00/00
Lbs 27 27 27
Shipping Weight
Kg 12.2 12.2 12.2

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F9
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 32 IWG


• Maximum vacuum: 31.3 IWG
• Standard motor: 0.5 HP, ODP

• Motor with permanently sealed ball bearings



• Quiet operation within OSHA standards
• Thermal overload protection

OPTIONS
• International voltage & frequency (Hz)
• Hermetically sealed
• UL & CSA approved motor
• Remote drive (motorless) model

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 10 20 31 41 51 61 71 82 92 102 112 0 10 20 31 41 51 61 71 82 92 102 112
36 90 36 90
Legend Legend
30 Pressure: 75 30 Pressure: 75
Suction: Suction:
Spiral SL2 Spiral SL2
Inches of Water
Inches of Water

24 60 24 60
mbar

mbar
18 45 18 45

12 30 12 30

6 15 6 15

0 0 0 0
0 6 12 18 24 30 36 42 48 54 60 66 0 6 12 18 24 30 36 42 48 54 60 66

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 10
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
6.56 MAX. 9.24
166.6 234.7
7.21 5.76
183.1 146.3
6.00 4.56 MAX.
152.4 115.8

CAPACITORS ON SINGLE
PHASE MODELS ONLY
1/2” CONDUIT HOLE
(1) EACH END

1.75 O.D.
1.60 I.D.

44.5
40.6
13.03 MAX.
331

OUT

1.62
41.2
104.7

9.89 DIA.
4.12

251.2
253.2
9.97

2.62
66.6
IN

3.00 TYP. 1.38 2.92


.25-20 UNC-2B X .31 DEEP
76.2 35.1 74.2 (6) MOUNTING HOLES EACH END
2.87 3.17
IN
MM 72.9 80.5

NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SL4P2 SL4P52

Specification Units 036009 036027


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS
Horsepower - .75 .75
Voltage AC 115 208-230
Phase - Frequency - Single-50/60 Hz Single 60 Hz
Insulation Class - B B
Full - Load Amps Amps (A) 3.70/3.80 2.29/2.20
Service Factor - 1.0 1.0
Locked Rotor Amps NEMA Amps (A) 14.0 7.0
Starter Size - 00/00 00/00
Lbs 42 42
Shipping Weight
Kg 19.1 19.1

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 11
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 60 IWG


• Maximum vacuum: 55.8 IWG
• Standard motor: 0.75 HP, ODP

• Motor with permanently sealed ball bearings



• Quiet operation within OSHA standards
• Thermal overload protection

OPTIONS
• International voltage & frequency (Hz)
• Hermetically sealed
• UL & CSA approved motor
• Remote drive (motorless) model

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 14 27 41 54 68 82 95 109 122 136 150 0 14 27 41 54 68 82 95 109 122 136 150
60 150 60 150
Legend Legend
50 Pressure: 125 50 Pressure: 125
Suction: Suction:
Spiral SL4 Spiral SL4
Inches of Water
Inches of Water

40 100 40 100
mbar

mbar
30 75 30 75

20 50 20 50

10 25 10 25

0 0 0 0
0 8 16 24 32 40 48 56 64 72 80 88 0 8 16 24 32 40 48 56 64 72 80 88

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 12
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower

9.24
234.7

6.00 7.21 5.76


152.4 183.1 146.3

6.56 MAX. 4.56 MAX.


166.6 115.8

CAPACITORS ON SINGLE
PHASE MODELS ONLY
1/2" CONDUIT HOLE
(1) EACH END

1.75 O.D.
1.60 I.D.
40.6

44.5
13.03 MAX.

IN

104.7

1.62
41.2

9.89 DIA.
4.12
331

253.2
9.97

2.62
66.6

251.2
OUT

3.00 TYP. 1.38 2.92


3.51 74.2 .25-20 UNC-2B X .31 DEEP
76.2 (6) MOUNTING HOLES EACH END
IN
MM 2.87 3.17
72.9 80.5

NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

SL5P2 SL5P52

Specification Units 036010 036261


Motor Enclosure - Shaft Mtl. - ODP-CS ODP-CS
Horsepower - .75 .75
Voltage AC 115 208-230
Phase - Frequency - Single-50/60 Hz Single 60 Hz
Insulation Class - B B
Full - Load Amps Amps (A) 4.58/6.75 1.85/2.55
Service Factor - 1.0 1.0
Locked Rotor Amps NEMA Amps (A) 14.0 7.0
Starter Size - 00/00 00/00
Lbs 42 42
Shipping Weight
Kg 19.1 19.1

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 13
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 31 IWG


• Maximum vacuum: 31.3 IWG
• Standard motor: 0.75 HP, ODP

• Motor with permanently sealed ball bearings



• Quiet operation within OSHA standards
• Thermal overload protection

OPTIONS
• International voltage & frequency (Hz)
• Hermetically sealed
• UL & CSA approved motor
• Remote drive (motorless) model

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 17 34 51 68 85 102 119 136 153 170 187 0 17 34 51 68 85 102 119 136 153 170 187
36 90 36 90
Legend Legend
30 Pressure: 75 30 Pressure: 75
Suction: Suction:
Spiral SL5 Spiral SL5
Inches of Water
Inches of Water

24 60 24 60
mbar

mbar
18 45 18 45

12 30 12 30

6 15 6 15

0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 14
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Nautilair

A .495 (12.57)
K
B NC33A NC33AE9 NC33AG58
G (STD) (TEFC) (XP)
C V 11.55 11.55 11.55
X Z (4X) MTG HOLES A
(293.2) (293.2) (293.2)
KNOCKOUT FOR 0.28 DIA
6.07 6.07 6.07
AIRFLOW SWITCH B
(154.2) (154.2) (154.2)
5.38 (136.65)

(BOTH SIDES) J

U
0.495 0.495 0.495
D (REF)

N
M

O
(12.6) (12.6) (12.6)

11.3 (286.96)
L
Y
W 6.04 6.04 6.04

P
D
(153.4) (153.4) (153.4)
E

F 10.76 10.76 10.76


E
(273.3) (273.3) (273.3)
5.19 5.19 5.19

Ø5.19 (131.83)
F
(131.8) (131.8) (131.8)
4.25 4.25 4.25
1.75 (44.45) R S G
Ø.40 (108) (108) (108)
3.5 (88.90) 2.50 (63.50)
HOLE (4X) 0.25 0.25 0.25
AA H
(6.4) (6.4) (6.4)
T
TEFC MODEL J
1.75
(44.5)
1.75
(44.5)
1.75
(44.5)
5.10 5.10 5.10
K
(129.5) (129.5) (129.5)
3.13 3.13 3.13
L
(79.5) (79.5) (79.5)
4.75 4.75 4.75
A .495 (12.57) M
K (120.7) (120.7) (120.7)
B G 5.59 5.59 5.59
N
C V (142) (142) (142)
X Z (4X) MTG HOLES 5.90 5.90 5.90
H (TYP.) O
KNOCKOUT FOR 0.28 DIA (149.9) (149.9) (149.9)
AIRFLOW SWITCH 6.0 6.0 6.0
(BOTH SIDES) P
(152.4) (152.4) (152.4)
3.49 (88.75)

U
1.97 3.52 4.20

M
N
O
D

L R
Y (50) (89.4) (106.7)
1.23 (31.35)

W
2.78 2.78 2.78
E

S
(70.6) (70.6) (70.6)
F P (DIA. INLET)
Ø7.69 (195.28) 7.26 13.35 13.94
T
(184.4) (339.1) (354.1)
2.38 2.38 2.38
U
(60.5) (60.5) (60.5)
1.50 (38.10)
1.75 (44.45) 2.13 2.13 2.13
R S V
HOLES FOR ELECTRICAL CONNECTIONS (54.1) (54.1) (54.1)
3.50 (88.90) 2.53 (64.31)
2.96 2.96 2.96
1/4-20 UNC-2B X .50 DP. T W
(75.2) (75.2) (75.2)
(4) MTG HOLES EQUALLY
SPACED ON A 3.625 DIA. B.C. 0.84 0.84 0.84
X
(21.3) (21.3) (21.3)
1/4-20 UNC-2B X .50 DP.
(4) MTG HOLES 4.0 4.0 4.0
Y
(101.6) (101.6) (101.6)
2.5 2.5 2.5
IN STANDARD MODEL Z
(63.5) (63.5) (63.5)
MM
7.13
AA --- ---
(181.1)
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

NC33A2G NC33A3G NC33A33G NC33AE9 NC33AG58

Specification Units 037791 037792 037793 080114 080113


Phase - Frequency - Single-50/60 Hz Single-50/60 Hz Three-50/60 Hz Single-50/60 Hz Single-50/60 Hz
Voltage AC 115 220/230 208-230 115/230 115/230
RPM on 50/60 Hz - 2900/3500 2900/3500 2900/3500 2900/3500 2900/3500
Insulation Class - B B B F F
Full - Load Amps Amps (A) 3.44/3.84 1.47/1.82 1.10/1.18 6.0/3.0 4.4
Locked Rotor Amps Amps (A) 8.25 4.0 5.0 21/10.5 38/19
Lbs 18 18 18 28 30
Shipping Weight
Kg 8.2 8.2 8.2 12.7 13.6
Motor Enclosure - Standard Standard Standard TEFC XP

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 15
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
Nautilair

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 3.5 IWG


• Thermoset plastic blower housing with aluminum impeller
• Permanently seal ball bearings in motor - L10 bearing life: 50,000 hours
• Quiet operation within OSHA standards
• Shipping weight: 18 lbs (8.2 kg) for standard model
28 lbs (12.7 kg) for TEFC model
30 lbs (13.6 kg) for XP model
• Designed for UL and CSA
• Automatic thermal overload protection on standard motor enclosures

80 90
3 FEET (0.91 METERS) FROM NOISE SOURCE
EQUIVALENT SOUND PRESSURE LEVEL –

70 80
db (re 0.0002 microbar)

SOUND POWERLEVEL –
db (re 10 -12Watts)

60 70

NC33
50 60

40 50
20 75 150 300 600 1200 2400 4,800
75 150 300 600 1200 2400 4800 10,000
OCTAVE BAND CENTERFREQUENCY Hz

Blower Performance at Standard Conditions


60 Hz 50 Hz

Air Flow Rate - m3/hour Air Flow Rate - m3/hour


0 85 170 255 340 425 510 595 680 765 850 935 0 85 170 255 340 425 510 595 680 765 850 935
6 15.0 6 15.0
Legend Legend
5 Pressure: 12.5 5 Pressure: 12.5
Suction: Suction:
NC33 NC33
Inches of Water
Inches of Water

4 10.0 4 10.0
mbar

3 7.5 3 7.5 mbar

2 5.0 2 5.0

1 2.5 1 2.5

0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 0 50 100 150 200 250 300 350 400 450 500 550

Air Flow Rate - SCFM Air Flow Rate - SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 16
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
DR 404/454/505/513/656
Spa Blowers

F L
GND LUG 1.021
25.9

165.1
6.50
G

IN E
IN T-BOX
0.42
MM
10.7
D 1/2-14 NPSM
NOTES THREAD
1 DRAWING NOT TO SCALE, CONTACT FACTORY "P" DIA
FOR SCALE CAD DRAWING. A I H
2-" NPSC (4) MTG
2 CONTACT FACTORY FOR BLOWER MODEL B
THREAD HOLES
LENGTHS NOT SHOWN.
C J

MODEL A (IN/MM) B (IN/MM) C (IN/MM) D (IN/MM) E (IN/MM) F (IN/MM) G (IN/MM) H (IN/MM) I (IN/MM) J (IN/MM) K (IN/MM) L (IN/MM)
DR404AQ58M 4.75/120.7 8.93/226.8 10.12/257 192/48.8 6.28/159.5 11.5/292.1 12.16/308.9 3.0/76.2 3.75/95.3 12.88/372.2 .59/15 12.91/327.9
DR454V58 4.75/120.7 10.30/261.6 11.38/289.1 1.92/48.8 6.98/177.3 12.55/318.8 13.52/343.4 3.25/82.6 4.50/114.3 10.81/274.6 .59/15 14.45/367
DR505AW58M 4.75/120.7 10.30/261.6 11.70/297.2 1.87/47.5 7.26/184.4 13.53/343.7 14.38/365.3 3.56/92.7 4.50/114.3 14.38/365.3 .59/15 15.0/381
DR513V58 4.75/120.7 11.42/290.1 13.0/330.2 2.23/56.6 8.69/220.7 14.21/360.9 15.8/401.3 3.72/94.5 5.50/139.7 13.74/349 .59/15 14.58/370.3
DR656K58X 4.92/125 11.42/290.1 12.8/325.1 2.25/57.2 7.46/189.5 15.42/391.7 15.17/385.3 4.14/105.2 5.5/139.7 15.12/384.1 .59/15 15.51/393.9

Part/Model Number

DR404AQ58M DR454V58M DR505AW58M DR513V58 DR656K58X

Specification Units 037778 080485 037935 038143 080603


Motor Enclosure - Shaft Mtl. - SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS TEFC-CS
Horsepower - 1.0 1.5 2.0 1.5 3.0
Voltage AC 115/230 115/230 115/230 115/230 115/230
Phase - Frequency - Single-50/60 Hz Single-50/60 Hz Single-50/60 Hz Single-50/60 Hz Single-50/60 Hz
Insulation Class - F F F F F
NEMA Rated Motor Amps Amps (A) 15/7.5 15.2/7.6 21/10.5 15.2/7.6 31/15.5
Service Factor - 1.4 1.3 1.2 1.3 1.0
Maximum Blower Amps Amps (A) 8/4 17/8.5 26/13 17/8.5 27.8/13.9
Locked Rotor Amps Amps (A) 32/16 85/43 136/68 85/43 200/100
Recommended NEMA Starter Size- 0/00 1/0 1/0 1/0 1.5/1
Lbs 64 76 83 90 51
Shipping Weight
Kg 29 34.5 37.6 40.8 23.1
Recommended Number of Jets - 3-6 5-10 5-10 12-17 8-12

Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations. Our dual voltage 1 phase motors are factory tested
and certified to operate on both: 104-115/208-230 VAC-1 ph-60 Hz and 100-110/200-220 VAC-1 ph-50 Hz. All voltages above can handle a ±10% voltage
fluctuation. Special wound motors can be ordered for voltages outside our certified range.

Operating Temperatures - Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated
motors or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature). Performance
curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or ambient temperatures above 40°C.

Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or ambient
temperature reaches the maximum operating temperature.

Notes
- The blower should not be stopped/started more than four times an
hour. - Use of relief valve 515092 is required for all blowers.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 17
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
DR 404/454/505/513/656
Spa Blowers

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

• Maximum pressure: 56, 58, 74, 69 or 88 IWG


• Standard motor: 1.0, 1.5, 2.0, 3.0 HP, Spa Duty ODP

(threaded)
• UL & CSA approved motor with permanently sealed ball bearings and
Class B rated thermal protection

• Quiet operation within OSHA standards

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options
• Remote drive (motorless) models

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves


• Variable frequency drive package

Blower Performance at Standard Conditions


60 Hz 50 Hz
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
120 300 120 300
Legend Legend
100 Pressure: 250 100 Pressure: 250
Suction: Suction:
DR404 DR404
Inches of Water
Inches of Water

80 200 80 200
DR454 DR454
DR505 DR505
mbar

mbar
60 DR513 150 60 DR513 150
DR656 DR656
40 100 40 100

20 50 20 50

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220

Air Flow Rate - SCFM Air Flow Rate - SCFM


200 200
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

100 100

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
200 200
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

100 100

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 18
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
DR 10RDNT/SS10RDNT/HS 10RDNT
Remote Drive (Motorless) Blowers

Part/Model Number

DR10RDNT SS10RDNT HS10RDNT

Specification Units 036594


Shaft Material - Carbon Steel Stainless Steel Hastelloy
Speed Range - 1750-4500 1750-4500 1750-4500
Housing, Cover, Cover - Cast Iron Stainless Steel Hastelloy
Lbs 400 500 600
Shipping Weight
Kg 181.4 226.8 272.2

SS = Stainless Steel HS = Hastelloy

1 DR10RDNT not recommended for use with explosive gas due to material of construction.

2 Maximum operating temperature: Blower outlet air temperature should not exceed 260°C (air temperature rise plus inlet temperature).
Contact factory for use above 260°C blower outlet air temperature.
3 AMETEK will not be liable for blowers operated beyond factory specific RPM.

4 All applications must be reviewed. Contact application engineering for assistance.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 19
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
DR 10RDNT/SS10RDNT/HS 10RDNT
Remote Drive (Motorless) Blowers

FEATURES
• Manufactured in the USA - ISO 9001 and NAFTA compliant

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options

• Packaged on baseplate with V-belts or coupling, guard & motor


• High temperature Viton® seals
• Krytox® grease high temperature bearings

PACKAGE/MOTOR OPTIONS
• International voltage & frequency (Hz)

• Packing gland or double faced seal options

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

• External mufflers for additional silencing


• Variable frequency drive package

Note: For accessories, special high temperature models may be required

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 127 255 382 510 637 765 892 1019 1147 1274 1402 0 127 255 382 510 637 765 892 1019 1147 1274 1402
180 450 180 450
AIR T 100 ºC
150 375 150 375
75 ºC
120 300 120 AIR T 100 ºC 300
Inches of Water
Inches of Water

mbar

mbar
90 50 ºC
225 90 75 º C 225

60 4500 RPM 150 60 50 º C 150


2500 RPM 3500 RPM 4500 RPM
3500 RPM

30 75 30 2500 RPM 75
1750 RPM
1750 RPM
0 0 0 0
0 75 150 225 300 375 450 525 600 675 750 825 0 75 150 225 300 375 450 525 600 675 750 825

Air Flow Rate - SCFM Air Flow Rate - SCFM


40 40
4500
4500
Horsepower
Horsepower

Input
Input

20 3500 20
3500

2500 2500
1750 1750
0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 20
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower

4.12 OUTLET INLET


104.7
1-11 1/2 NPT
2X

Ø .87 CONDUIT HOLE


RESET BUTTON 22

ROTATION

3.00
76.2
Ø 9.84
249.9

2.62
66.5
1.69
42.9
1.88 Ø .28 MOUNTING HOLE
47.8 7.1
6.00 3.50
152.4 88.9
TEFC MOTOR
15.00 MD101CB4 MODEL SHOWN
381
4.12
104.7 INLET
OUTLET
1-11 1/2 NPT
2X
LEADS FAR SIDE .75-14 NPT
Ø 9.84

3.00
249.9

76.2
ROTATION

66.5
2.62
1.69
42.9
1.88 XP MOTOR
47.8 MD101CC4 MODEL SHOWN Ø .28 MOUNTING HOLE
IN 6.00 8.25
209.6 7.1
MM 152.4
3.50
16.6 88.9
NOTES 421.6
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.

Part/Model Number

MD101CB4 MD101CC4

Specification Units 038014 038271


Motor Enclosure - Shaft Mtl. - TEFC Explosion-proof
Horsepower - .25 .25
Phase - Frequency Voltage - Single-60 hz Single-60 hz
Motor Nameplate Amps AC 115 115
Max. Blower Amps Amps (A) 2.6 2.6
Locked Rotor Amps Amps (A) 2.2 2.2
Service Factor Amps (A) 6.4 7.2
Starter Size - 1.0 1.0
Thermal Protection - 00 00
XP Motor Class - Group - Class B - Automatic, Manual Reset Class B - Automatic
- - I-D
Lbs 40 40
Shipping Weight
Kg 18.1 18.1

1 Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors
or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or
ambient temperatures above 40°C.
Rev. 2/04
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 21
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower

FEATURES
• Hermetically designed seal-less blower
• Continuous operation
• Manufactured in the USA

• Maximum pressure: 28 IWG


• Maximum vacuum: 26.5 IWG
• Standard motor: 0.25 HP, TEFC or XP
• Disconnect motor without disassembling from piping

• Permanently sealed ball bearings in housing and motor


• Quiet operation within OSHA standards

BLOWER OPTIONS
• Corrosion resistant surface treatments & sealing options

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 5 10 15 20 25 30 35 40 45 50 55 0 5 10 15 20 25 30 35 40 45 50 55
30 75 30 75

25 62 25 62

20 50 20 50
Inches of Water
Inches of Water

AIR
AIR SG = 1.0
mbar

mbar
15 SG = 1.0 37 15 37

10 25 10 25
NATURAL GAS NATURAL GAS
SG = 0.56 SG = 0.56
5 12 5 12

0 0 0 0
0 3 6 9 12 15 18 21 24 27 30 33 0 3 6 9 12 15 18 21 24 27 30 33

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 22
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
GVR313
Regenerative Blower
10.50
266.7 14.19
360.4

95.3
3.75
ROTATION

11.38 (TYP.)
289.1
2.2
IN OUT
55.9

4.00 1 1/2" NPTF (2) PLACES (GVR313)


101.6
6.875 4.2
174.6 106.7

.34
.88 8.6
IN

124.5
4.9
22.4
MM

165.1
6.5
NOTES
1 DRAWING NOT TO SCALE, CONTACT FACTORY FOR SCALE CAD DRAWING.
2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN.
BOTTOM VIEW
3 GVR313AK4H MODELS SHOWN

Part/Model Number

GVR313AK4H GVR313AK58H GVR313AK72HA GVR313AK91H GVR313AE4HA

Specification Units 038584 081531 081470 081524 080274


Motor Enclosure - Shaft Mtl. - Explosion-proof - CS Explosion proof - CS Explosion proof - CS ATEX - CS TEFC
Horsepower - 0.5 0.5 0.5 0.75 0.5
Phase - Frequency Voltage - Single-60 hz Single-50/60 Hz Three-60 Hz Three-50 Hz Single-60 Hz
Motor Nameplate Amps AC 115 110/220 230/460 400 115
Max. Blower Amps Amps (A) 9.4 8.4/4.2 1.4/0.7 1.4 7.4
Locked Rotor Amps Amps (A) 7.6 6.8/3.4 1.4/0.7 1.1 7.4
Service Factor Amps (A) 45 45 10.2/5.1 9 47
Starter Size - 1.0 1.0 1.15 1.0 1.0
Thermal Protection - 0 0 00 0 0
XP Motor Class - Group - Class B - Automatic Class B - Automatic Class B - Automatic Thermistors Class B - Automatic
- I-D 1-D 1-D EExd IIB 1-D
Lbs 39 39 39 45 39
Shipping Weight
Kg 17.7 17.7 17.7 20.4 17.7

1 115 voltage, 1 phase motors are standard. 230 volt motors available. As an option, a transformer could be used.
2 Maximum operating temperature: Motor winding temperature (winding rise plus ambient) should not exceed 140°C for Class F rated motors
or 120°C for Class B rated motors. Blower outlet air temperature should not exceed 140°C (air temperature rise plus inlet temperature).
Performance curve maximum pressure and suction points are based on a 40°C inlet and ambient temperature. Consult factory for inlet or
ambient temperatures above 40°C.
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40°C inlet and/or
ambient temperature reaches the maximum operating temperature.

Rev. 2/04

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 23
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Specific Blowers
GVR313
Regenerative Blower

FEATURES
• Manufactured in the USA

• Maximum pressure 45 IWG


• Maximum vacuum: 40.8 IWG
• Standard motor: 0.5 HP, TEFC
• Anodized cast aluminum blower housing, impeller & cover

• Quiet operation within OSHA standard


• ROHS gold irridite coatings on aluminum surfaces

MOTOR OPTIONS
• International voltage & frequency (Hz)

BLOWER OPTIONS

ACCESSORIES
• Flowmeters reading in SCFM
• Filters & moisture separators
• Pressure gauges, vacuum gauges, & relief valves

Blower Performance at Standard Conditions


Pressure Suction
Air Flow Rate - m3/hour Air Flow Rate - m3/hour
0 9 17 26 34 43 51 60 68 77 85 94 0 9 17 26 34 43 51 60 68 77 85 94
60 150 60 150

50 125 50 125

40 100 40 100
Inches of Water
Inches of Water

GVR313
mbar

mbar
30 75 30 75
GVR313

20 50 20 50

10 25 10 25

0 0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 0 5 10 15 20 25 30 35 40 45 50 55

Air Flow Rate - SCFM Air Flow Rate - SCFM


100 100
Motor Winding
Motor Winding

Temp Rise °C
Temp Rise °C

50 50

0 0
Temperature curves are based on standard model Temperature curves are based on standard model
100 100
Temp Rise °C
Temp Rise °C

Blower Air
Blower Air

50 50

0 0

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 F 24
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
AMETEK Dynamic Fluid Solutions' ROTRON brand has long been a world leader in regen-
erative blower technologies, bringing regenerative advantages to a new level, providing quiet,
maintenance-free, oil-free operation.

Our accessories for regenerative blowers inlude:

Filtration Accessories
Measurement Accessories
Noise Reduction Accessories
Valves and Gauges
VFD Drives
Air Knives

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP656, 6, 633, S7
B = DR/EN/CP068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9,nlet
P9 (I
Only)
C= DR/EN/CP303, 312, 313, 353 G = DR/EN/CP833, S13,P13(Inlet Only)
D = DR/EN/CP404, 454, 513, 505, 555, 523 H = DR/EN/CP909, 979, 1233,14, S15,P15(Inlet Only)

Blower Connection Key


NPT– AmericanNational StandardTaper Pipe Thread(Male)
NPSC– AmericanNational StandardStraight Pipe Threadfor Coupling (Female)
SO– Slip On (Smooth – No Threads)

AMETEK DYNAMIC FLUID SOLUTIONS


75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Accessories
Filtration - Inlet Filter (Single Connection)

Inlet Filters protect the blower and the air distribution


system from dust, and other airborne particles and
contaminants. Normally used in pressure systems.

SPECIFICATIONS:
HOUSING – Steel

C Ø
A Ø
MEDIA – Polyester
EFFICIENCY – 97-98% (8 to 10 micron particle size)
FILTER ELEMENT – Replaceable (see filter
elements) NOTE: “Z” MEDIA (1 to 3 micron particle
size) available

Part/Model Number

Specification Units 477411 516466 515122 515123 515124 515125 515145 515151 516511
Filter Element - A B C, D E E F G H H
Ref Blower Model - 271078 515132 515132 515133 515134 515134 515134 515135 516515
Outlet Connection - 2.00 SO 1.00 NPT 1.50 NPT 2.00 NPT 2.00 NPT 2.50 NPT 3.00 NPT 4.00 NPT 6.00 NPT
Inches 4.56 6.00 6.00 7.75 10.00 10.00 10.00 10.00 16.00
Dimension A
mm 115.8 152.4 152.4 196.9 254 254 254 254 406.4
Inches 6.12 6.50 6.50 7.25 12.25 12.50 13.00 14.00 15.00
Dimension B
mm 155.4 165.1 165.1 184.2 311.2 317.5 330.2 355.6 381
Inches 2.00 1.00 1.5 2.00 2.00 2.50 3.00 4.00 6.00
Dimension C
mm 50.8 25.4 38.1 50.8 50.8 63.5 76.2 101.6 152.4
Z Media Filter PN - 517865 517866 517867 517868 517869 517870 517871 517872

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763
1258 Customer Service Fax: +1 215.256.1338
G1
www.ametekdfs.com ____
Accessories
Filtration - Inline Filter (Dual Connection)

Inline Filters protect the blower from harmful dust


and other particles that may be drawn into the
blower through the air distribution system.
Normally used in vacuum systems. C DIA.

SPECIFICATIONS: Inline filter PN 271200 is a straight through design


Inlet is directly opposite of outlet
HOUSING – Steel B

MEDIA – Polyester
EFFICIENCY – 97-98% (8 to 10 micron particle size)
FILTER ELEMENT – Replaceable (see filter
elements) NOTE: “Z” MEDIA (1 to 3 micron particle
size)
* available
Feature 1/4" threaded tap for gauge connection on inlet and outlet D DIA.

Part/Model Number

Specification Units 271200 516461 515254 515255 515256 516463* 516465* 517611*
Filter Element - 271078 516434 516434 516435 516435 515135 515135 516515
Ref Blower Model - A B C, D E F G H H
Inlet Connection - 1.75 SO 1.00 NPSC-F 1.50 NPSC-F 2.00 NPSC-F 2.50 NPSC-F 3.00 NPT-M 4.00 NPT-M 6.00 NPT-M
Outlet Connection - 2.00 SO 1.00 NPSC-F 1.50 NPSC-F 2.00 NPSC-F 2.50 NPSC-F 3.00 NPT-M 4.00 NPT-M 6.00 NPT-M
Inches 5.25 7.25 7.00 8.00 8.00 14.00 14.00 18.00
Dimension A
mm 133.4 184.2 177.8 203.2 203.2 355.6 355.6 457.2
Inches 8.31 6.50 6.50 10.25 10.25 26.50 27.00 28.00
Dimension B
mm 211.1 165.1 165.1 260.4 260.4 673.1 685.8 711.2
Inches 2.00 1.00 1.50 2.00 2.50 3.00 4.00 6.00
Dimension C
mm 50.8 25.4 38.1 50.8 63.5 76.2 101.6 152.4
Inches 1.75 1.00 1.50 2.00 2.50 3.00 4.00 6.00
Dimension D
mm 44.5 25.4 38.1 50.8 63.5 76.2 101.6 152.4
Z Media Filter PN - 517886 517887 517888 517889 517890 517891 517892

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Filtration - Filter Silencers (Single Connection)

Filter/Silencers reduce noise levels while


ensuring clean air is provided to the blower and B

the air distribution system. Normally used in


pressure applications.

SPECIFICATIONS:
HOUSING – Steel
MEDIA – Polyester

A Ø

C Ø
EFFICIENCY – 97-98% (8 to 10 micron size)
FILTER ELEMENT – Replaceable (see filter elements)

Part/Model Number

Specification Units 516487 516489 516491 516493 516495 516497 516499 516513
Filter Element - B C, D E E F G H H
Ref Blower Model - 515132 515132 515133 515134 515134 515134 515135 516515
Outlet Connection - 1.00 NPT 1.50 NPT 2.00 NPT 2.00 NPT 2.50 NPT 3.00 NPT 4.00 NPT 6.00 NPT
Inches 6.00 6.00 10.00 10.00 10.00 10.00 12.33 16.00
Dimension A
mm 152.4 152.4 254 254 254 254 313 406.4
Inches 6.50 6.50 7.25 12.25 12.50 12.50 13.87 15.00
Dimension B
mm 165.1 165.1 184.2 311.2 317.5 317.5 352 381
Z Media Filter PN - 517878 517879 517880 517881 517882 517883 517884 517885
Inches 1.00 1.50 2.00 2.00 2.50 3.00 4.00 6.00
Dimension C
mm 13154101.2 13154126.6 13154152 13154177.4 13154202.8 13154228.2 13154253.6 13154279

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763
1258 Customer Service Fax: +1 215.256.1338
G3
www.ametekdfs.com ____
Accessories
Filtration - Filter Element

All ROTRON Air Filters and Filter/Silencers have


replaceable filter elements. The filter media is polyester
designed for high efficiency over a wide spectrum of ØID

industrial applications. See ÿlter element cross reference


table. Filter elements supplied with foam pre-filter.
Standard Replacement Filter Element Cross Reference Table
Filter Element Filter Element Filter Element

271200 271078 515158 515134 516489 515132


477411 271078 515254 516434 516491 515133
515122 515132 515255 516435 516493 515134
515123 515133 515256 516435 516495 515134
515124 515134 516461 516434 516497 515134
HT ØOD
515125 515134 516463 515135 516499 515135
515145 515134 516465 515135 516511 516515
515151 515135 516466 515132 516513 516515 For DR Blower Models
515157 515133 516487 515132 517611 516515

Part/Model Number

Specification Units 515132 515133 515134 515135 516434 516435 516515


Z Media Filter PN - 517873 517874 517875 517876 517893 517894 517877
Inches 3.00 3.63 3.5 4.75 2.56 3.50 8.00
Dimension ID
mm 76.2 92.2 88.9 120.7 65 88.9 203.2
Inches 4.38 5.88 5.88 7.88 5.00 5.88 11.75
Dimension OD
mm 111.3 149.4 149.4 200.2 127 149.4 298.5
Sq/Ft 4.75 4.75 9.50 9.63 4.75 8.75 9.63
Area
Sq/M 0 0 1 1 0 1 1
Inches 1.5 2.3 4.5 8.3 2.0 4.5 19.0
Dimension HT
mm 38.1 58.4 114.3 210.8 50.8 114.3 482.6

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763
1258 Customer Service Fax: +1 215.256.1338
G4
www.ametekdfs.com ____
Accessories
Filtration - Moisture Separator

By separating and containing entrained liquids, SPECIFICATIONS:


ROTRON’S™ moisture separator helps protect our SEPARATION METHOD – High Effciency Cyclonic
regenerative blowers and the end treatment system RELIEF VALVE MATERIAL – Brass & Stainless Steel
from corrosion and mineralization damage. FLOAT MATERIAL – Copper
Recommended for all soil vacuum extraction FLOAT SWITCH – SPDT, Explosion-proof
Applications.
NEMA 7&9, 5 Amp max.
"A" O.D.
"A" O.D. INLET
1/4" NPT FLOAT LEVEL INLET 1/4" NPT FLOAT LEVEL 1/4" NPT
(PLUGGED) SWITCH (PLUGGED) SWITCH (PLUGGED)
(OPTIONAL) (OPTIONAL)
"A"O.D.
INLET
H

applications.
H H
VACUUM GAUGE
(OPTIONAL) VACUUM GAUGE
(OPTIONAL)
VACUUM RELIEF
VALVE VACUUM RELIEF VACUUM GAUGE
G (OPTIONAL)

3.90 (OPTIONAL LOW SWITCH)


FLOAT SWITCH OUTLET VALVE
(OPTIONAL) G
3/4" NPT MOISTURE SEPARATOR
OUTLET
M OI S T U R E
VACUUM RELIEF
TM

S E P A R AT OR
VALVE G
OUTLET
MOISTURE SEPARATOR
F
E

INSTALL FLOAT SW.

F
URE TM
CYCLONIC
ACTION
B

WATER LEVEL T OR

B
CAUTION:

E
E
F
J
FREEZING MAY CAUSE DAMAGE.

CAPACITY
MOISTURE SEPARATORS USED IN
TEMPERATURES BELOW 32øF (0øC)
MUST BE PROPERLY WINTERIZED.

DRAIN (PER CHART) DRAIN

B
INFO PACKET
3/4" 3/4"
J

NPT

J
NPT

D
D

C C DRAIN - 1" NPT INTERNAL THD

PLASTIC “P” DESIGN METAL “D” DESIGN METAL “B” DESIGN

Part/Model Number

MS200PS MS300PS MS350BS MS500BS MS600BS MS1000BS

Specification Units 038519 038520 038357 080660 080659 038914


Inches 2.38 2.88 3.25 3.25 4.00 6.00
Dimension A
mm 60.5 73.2 82.6 82.6 101.6 152.4
CFM 200 300 350 500 600 1000
CFM Max.
m3/hr 340 510 595 850 1020 1700
Inches 22.46 22.46 28.00 28.00 27.00 31.00
Dimension B
mm 570.5 570.5 711.2 711.2 685.8 787.4
Inches 16.00 16.00 23.00 23.00 23.00 27.00
Dimension C
mm 406.4 406.4 584.2 584.2 584.2 685.8
Inches 3.25 3.25 4.00 4.00 4.00 4.00
Dimension D
mm 82.6 82.6 101.6 101.6 101.6 101.6
Inches 31.05 31.05 37.25 37.37 37.37 47.32
Dimension E
mm 788.7 788.7 946.2 949.2 949.2 1201.9
Inches 33.30 33.30 39.50 54.50 54.50 51.70
Dimension F
mm 845.8 845.8 1003.3 1384.3 1384.3 1313.2
Inches 6 6.00 9.75 9.75 9.25 10.00
Dimension H
mm 152.4 152.4 247.7 247.7 235 254
Inches 4.50 OD 4.50 D 4.50 OD 6.63 ID 6.63 ID 8.62 OD
Dimension G
mm 114.3 114.3 114.3 168.4 168.4 218.9
Inches 13.25 13.25 17.50 17.50 17.50 19.88
Dimension J
mm 336.6 336.6 444.5 444.5 444.5 505
Drain Internal Thd - 3/4 3/4 1 1 1 1
Lbs 42 42 82 95 96 150
Shipping Weight 37.2
Kg 19.1 19.1 43.1 43.5 68

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Filtration - Moisture Separator

2.0 Moisture SeparatorTM Specifications


2.1 Duty
The moisture separator shall be designed for use in a soil vapor
extraction system capable of continuous operation with a
pressure drop of less than six inches of water at the rated flow of For Selector Liquid- Max
_____ SCFM. The separator shall be capable of operation under DR/EN/CP Moisture holding Inlet Vacuum
various inlet conditions randing from a fine mist to slugs of water Outlet
Blower Separator Capacity (OD) Allow
with high efficiency.
Model Model (gallons) (IHG)
2.2 Principle of Operation 404
454
The moisture separator shall incorporate cyclonic separation to
remove entrained water. The separator must protect against an 505
overflow by fail safe mechanical means. An electrical switch or 513 MS200PS 7 2.38 12
contact(s) alone is not an acceptable means of protection against 523
overflow, but is a good backup. 555
4.5 OD
633
2.3 Construction 833
656
The body of the moisture separator shall be constructed of heavy
6 MS300PS 7 2.88
wall plastic or heavy gauge cold rolled steel. The steel interior
and exterior shall be epoxy (powder) coated to resist abrasion, 757
corrosion, and chipping that might expose the surface. The inlet 808 MS350BS
shall be tangentially located and welded to the body. The outlet 858 3.25
MS500BS 40 22
port shall be constructed of PVC or cast aluminum alloy, flanged 1233 6.63 ID
and sealed to the center of the top of the separator. The 909 MS600BS 4.0
separator shall incorporate a non-sparking copper float ball and 979
an adjustable relief valve to protect against overflow and MS1000BS 65 6.0 8.62 OD
14
overheating the blower.

2.4 Capacity and Dimension


The moisture separator must have a liquid capacity of _____
gallons. The inlet shall be _____ inch OD slip-on type. The outlet
shall be _____ inch OD slip-on type.

2.5 Pressure Drop


6

5
Pressure Drop (IWG)

4
50BS
0PS

0BS
BS
MS200PS

BS
500

00
MS30

60
MS3

3
S1
MS
MS

0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Flow Rate (SCFM)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Measurement - Air Flow Meter

FEATURES BENEFITS
• Direct reading in SCFM
• Low pressure drop (2-4" typical) across • OPTIMIZE SYSTEM EFFICIENCY
the flow meter Measuring the correct air ˜ow can
• Non-clogging, low impedance air stream assist you in ÿne-tuning to your
• Light weight aluminum system’s optimal efficiency.
• No moving parts
• Large easy-to-read dial • BALANCE MULTI-PIPING SYSTEMS
• Accurate within 2% at standard conditions When evacuating CFM from more than one
• Good repeatability pipe, di˝erent run lengths or end system
• Available in 2", 3" and 4" sizes impedance can cause one pipe to handle
• Factory conÿgured for quick installation more CFM than the other. With an accurate
• .048" Allen key supplied for gauge adjustment CFM reading, piping can be balanced by
bleeding air in/out or by creating an extra
OPTIONS impedance.
• Corrosion-resistant version with Chem-Tough • DETECT CHANNELING OR PLUGGING
™ or in stainless steel For systems in which channeling or
• FDA-approved Food Tough™ surface conversion plugging can occur, a change in the CFM
measured can help indicate the unseen
changes in your system.

Part/Model Number

FM20C030Q FM20C045Q FM20C065Q FM20C125Q FM20C175Q FM20C225Q

Specification Units 550599 550600 550601 550602 550603 550604


CFM 6-30 9-45 13-65 25-125 35-175 45-225
Flow Rate
m3/hr 10-50 15-77 22-111 43-213 60-300 77-383
Threads B - 2-11.5 2-11.5 2-11.5 2-11.5 2-11.5 2-11.5
Inches 7.18 7.18 7.18 7.18 7.18 7.18
Dimension C
mm 182.4 182.4 182.4 182.4 182.4 182.4
Inches 7.0 7.0 7.0 5.8 5.8 5.8
Dimension D
mm 177.8 177.8 177.8 147.3 147.3 147.3
Inches 2.0 2.0 2.0 2.0 2.0 2.0
Dimension E
mm 50.8 50.8 50.8 50.8 50.8 50.8
Inches 3.75 3.75 3.75 3.75 3.75 3.75
Dimension F
mm 95.3 95.3 95.3 95.3 95.3 95.3

Part/Model Number

FM30C250Q FM30C350Q FM30C475Q FM40C450Q FM40C600Q FM40C850Q

Specification Units 550605 550606 550607 550608 550609 550610


CFM 50-250 70-350 95-475 90-450 120-600 170-850
Flow Rate
m3/hr 85-425 119-595 162-808 153-795 204-1020 289-1445
Threads B - 3-8 3-8 3-8 4-8 4-8 4-8
Inches 7.18 7.18 7.18 7.18 7.18 7.18
Dimension C
mm 182.4 182.4 182.4 182.4 182.4 182.4
Inches 7.0 7.0 7.0 5.8 5.8 5.8
Dimension D
mm 177.8 177.8 177.8 147.3 147.3 147.3
Inches 2.0 2.0 2.0 2.0 2.0 2.0
Dimension E
mm 50.8 50.8 50.8 50.8 50.8 50.8
Inches 3.75 3.75 3.75 3.75 3.75 3.75
Dimension F
mm 95.3 95.3 95.3 95.3 95.3 95.3

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G7
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Measurement - Air Flow Meter

TYPICAL FLOW METER ARRANGEMENT

3.75 PR E
S S URE 30
P. S.
A X I.
M G.

ØF
2.87
1.75
DIA. 210 280
140
070
S S URE
PRE 30
P. S.
A X I.

350
M G.

140
210 280
B
070 350
3.75

3.5
REGENERATIVE BLOWER GROUP

MINIHELIC II

REGENERATIVE BLOWER GROUP

MINIHELIC II

FLOW DIRECTION C
2.0
5.56
TYPICAL GAUGE FACE

MOISTURE SEPARATOR

E R U T S IO M
SYSTEM PIPING
MT

RO TA R A P ES

BLOWER

S SU
E R E 30
X PR .
P S. .
M A I G.

210 280
140
070 350

AMETEK
ROTRON T.I.P.
TECHNICAL & INDUSTRIAL PRODUCTS
MINIHELIC II

INLET FLOWMETER SYSTEM UNDER


VACUUM

HIGH TEMPERATURE/ PRESSURE HOW IT WORKS P1 P2


CORRECTION

SCFM 1

√( ) (
IN OUT
SCFM 2 =
14.7
Pf 2
x
530
Tf 2 + 460 )
Pf 2 = Absolute Pressure in ROTRON’S ˜ flow meter is a venturi style design.
PSIA Tf2 = Temperature in °F After air enters the inlet, the pressure is
measured in the P1 tap. The second tap, P2,
measures the pressure at the throat. The
differential between P1 and P2 registers across
• Use on inlet to limit need to correct for high a special calibrated CFM gauge to provide
pressure or elevated outlet temperature accurate readings. The throat is then expanded
back to the original size to keep pressure loss to
• Standard model limits = 140°F and 30 PSIG under
2-4 IWG.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G8
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Measurement - Digital Flowmeter
Remote air flow rate monitoring and system automation control can now be achieved through the use of 4-20 mA output signals.
Our 4-20 mA analog outputs are proportional to system flow rates and can be used with PLC controlled operations to monitor
system performance. Those same outputs provide digital displays for direct readings in SCFM when paired with our LCD Digital
Readout option. Combined with our Variable Frequency Drives, you can now achieve a completely automated system capable of
adjusting blower performance to meet changing system demands. Maintaining your system at peak performance gives your
company the competitive edge needed in today’s marketplace.
Ø.16 (2X)
DIFFERENTIAL PRESSURE TRANSMITTER MOUNT HOLES

4-20 mA signal output control signals provide flow rate


monitoring capabilities from remote locations
NEMA 1R-raintight enclosure orotects the integrated HIGH

DC power supply and rugged differential pressure


transducer

1.00

2.75

3.16
3.50
Suitable for remote mounting up to 10' form flow
LOW

meter Weight: 3 lbs.


- OUT +
COM EXC

Signal Output: 4-20 mA, DC1


Hi/Lo pressure fittings feature snap lock action to
unsure trouble-free connections2 1.14 .48 1.87
System includes standard flowmeter for on-site
readings and troubleshooting 3.583

Operating temperature: 0oF to 150oF


Drawing available

LCD DIGITAL READOUT OPTIONS


Factory configured to display direct readings in SCFM to 25.96
a remote location up to 50' from signal output1 NEMA 4, 1 2 3 4

IP65 enclosure ready for panel mount instlation power


supply and rugged differential pressure transducer
Suitable for remote mounting up to 10' form flow meter 3.780
installation
Power input: 120 VAC, 50/60Hz AC, Field configurable to
240VAC
Display: 5 digit, 7 segment, .5" high LED w/3.3Hz update
rate 1.89 1.69

Operating temperature: 10oC to 40oC


Weight: 1lb., 14oz.

Drawing available 5.51

Note 1: 4-20 mA output control wiring to be customer supplies. Shielded, 2 conductor


cables, 22 AWG is recommemeded for runs up to 100'. For longer runs contact factory

Note 2: Use 5/16" OD stiff wall tubing-connect "Lo" on flowmeter to "Lo" on 4-20 mA
enclosure, "Hi" on flowmeter to "Hi" on 4-20 mA enclosure. Tubing must be equal in
length. (Maximum length is 1o feet)

DIFFERENTIAL PRESSURE TRANSMITTER


FM20S030Q FM20S045Q FM20S065Q FM20S125Q FM20S175Q FM20S225Q FM30S250Q FM30S350Q FM30S475Q FM40S450Q FM40S600Q FM40S850Q
550838 550839 550840 550841 550842 550843 550844 550845 550846 550847 550848 550849

LCD DISPLAY
FM20L030Q FM20L045Q FM20L065Q FM20L125Q FM20L175Q FM20L225Q FM30L250Q FM30L350Q FM30L475Q FM40L450Q FM40L600Q FM40L850Q
550860 550861 550862 550863 550864 550865 550866 550867 550868 550869 550870 550871

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G9
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Noise Reduction - Sound Attenuating Enclosure

Frameless sound attenuating enclosures are a proven


SPECIFICATIONS:
way to reduce regeenrative blower mechanical noise
Roof, floor and walls: galvanized 16 ga. carbon steel
when additional mufflers are just not enough. Additional
sheet metal
enclosure options are available.
Louvers and/or hood: Riveted aluminum
Hardware: Chrome plated aluminum handles with
FEATURES:
stainless steel fastners
Excellent noise reduction (~10DbA)
Latches: Over center glvanized with adjustable
Resistance to elements and aesthetic appearance
tension and padlock eye
Compact size for ease of installation
Sound attenuating material: 2" rigid polyester foam
Easy access for routine maintenance (removable foor
with mylar facing (rated UL-94)
and sidewalls)
Exterior finish: Polyurethane enamel
LIFTING HOLE Enclosure ventilation: 1/3 HP, 230/460V, 3-phase or
(PLUGGED)
TWO (2) PER SIDE 18" FAN 1-phase 50/60Hz fan, TEFC or XP motors
(TOTAL 4) ASSEMBLY
Fan Guard: Nickel plated wire type

15.00

46.00

9.50 2.00 2.00


END SECTION
9.50 26.00 CLEAR
END SECTION
31.00 CLEAR 30.00

50.00

Part/Model Number

SAE30W72F SAE36W72F

Specification Units 552904 552905


Inches 30 36
Width
mm 762 914.4
Blower Size - 656, 707, 757, 808, 858, 909, 979, P9, S9 14, P13, S13, P15, S15
Inches 46 52
Height
mm 1168.4 1320.8
Inches 50 60
Length
mm 1270 1524

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 10
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Noise Reduction - Inlet/Outlet Muffler (Single Connection)

Mufflers lower blower noise in areas where reduced


sound levels are required. A
D

SPECIFICATIONS:
HOUSING – Steel
MEDIA – Acoustical Material

Part/Model Number

Specification Units 523627 523626 523625 523624 523623 523622


Ref Blower Model - B C D E E E
Inlet Connection - 1.0 NPT Male 1.25 NPT Male 1.50 NPT Male 2.00 NPT Male 2.00 NPSC Female 2.00 NPT Male
Inches 4.00 4.00 4.00 4.00 4.00 4.00
Dimension A
mm 101.6 101.6 101.6 101.6 101.6 101.6
Inches 10.93 10.93 10.93 10.93 10.93 15.75
Dimension B
mm 277.6 277.6 277.6 277.6 277.6 400.1
Inches 13.98 14.07 14.57 12.16 12.43 16.95
Dimension C
mm 355.1 357.4 370.1 308.9 315.7 430.5
Inches 1.00 1.25 1.50 2.00 2.00 2.00
Dimension D
mm 25.4 31.8 38.1 50.8 50.8 50.8

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 11
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Noise Reduction - Inline Muffler (Dual Connection)

Inline Mufflers are utilized for noise reduction in C

applications where piping systems are connected directly


to both ends of the muffler. Muffler may be used on inlet B

or outlet of blower.

SPECIFICATIONS: INLET A OUTLET


CONNECTION CONNECTION
HOUSING – Steel
MEDIA – Acoustical Material

Part/Model Number

Specification Units 550888 522948 529900 551377 515185 511569 515210 551565 516264
Ref Blower Model - D E E E F G G G H
Inlet Connection - 1.5 NPT-M 2.0 NPT-M 2.0 NPSC-F 2.0 NPT-M 2.5 NPT-M 3.0 NPT-M 4.0 NPT-M 4.0 NPT-M 4.0 NPT-M
Outlet Connection - 2.0 NPT-F 2.0 NPSC-F 2.0 NPSC-F 2.0 NPT-M 2.5 NPT-F 3.0 NPT-F 4.0 NPT-F 4.0 NPT-M 4.0 NPT-F
Inches 4.00 4.00 4.38 4.00 6.12 7.00 10.00 10.00 8.00
Dimension A
mm 101.6 101.6 111.3 101.6 155.4 177.8 254 254 203.2
Inches 7.75 15.75 15.75 15.75 15.00 18.00 24.00 24.00 22.00
Dimension B
mm 196.9 400.1 400.1 400.1 381 457.2 609.6 609.6 558.8
Inches 15.5 18.45 18.45 18.15 19.00 22.25 30.00 30.00 27.75
Dimension C
mm 393.7 468.6 468.6 461 482.6 565.2 762 762 704.9

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 12
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Protection - Relief Valve - Mechanical

Part/ Model Number

Specification Units 551026 551027 523230


Ref Blower Model - B, C, D D, E, F A, B, C, D, E, F
in. H2O 20-180 41.5-263 35-90
Range
mbar 49.8-448.4 103.4-655.1 87.2-224.2
Connection - 1 1/2 2 2
Description - Mechanical Mechanical Mechanical Vacuum Only

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS G 13
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 ____
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com
Accessories
Protection - Pressure Regulating Diaphram Valve

Fig. 1 Fig. 2
C
C
The PRD Valve is installed to prevent excessive SEE
NOTE
system pressure or vacuum that could result from DIFFERENTIAL
line restrictions. Valves should be installed at the ADJUSTMENT
SCREW
blower outlet (downstream) in pressure systems
and at blower inlet (upstream) in vacuum systems. D
GAUGE
These valves are suitable for air, natural gas, D
B PORT
propane, and other non-corrosive service.
GAUGE B
PORT
Note: PRD valves are not factory preset, but are
easily field adjustable.
A
SPECIFICATIONS: PRESSURE RELIEF: B is the system port and A is the vent or atmospheric port.
A

VALVE BODY – Aluminum (1"), Cast VACUUM RELIEF: A is the system port and B is the vent or atmospheric port. For vacuum
Iron (2") VALVE SPRING – Steel mode, customer must remove snap ring and screen.

DIAPHRAGM – Nitrile NOTE: Replace cap after adjusting setting. Valve will not operate with cap removed.
Differential adjustment screw is under the cap.

NOTE: Blower Model P13 requires two 515093 relief valves.

Part/Model Number

Specification Units 515092 529612 529857 529858 551130 515093 529859 550246 550247
in. H2O 27-125 110-415 277-554 7-18 14-62 48-194 110-277 97-197 97-194
Range
mbar 67.3-311.4 274-1033.8 690-1380 17.4-44.8 34.9-154.4 119.6-483.3 274-690 241.6-490.7 241.6-483.3
Description - Fig 1. Fig 1. Fig. 1 Fig. 2 Fig. 2 Fig. 2 Fig. 2 Pressure Vacuum
Ref Blower Model - B, C, D, E B, C, D, E B, C, D, E F, G F, G F, G F, G H H
Inlet Connection - 1 1 1 2 2 2 2 2.5 2.5
Outlet Connection - 1 1 1 2 2 2 2 2.5 2.5
Inches 1.00 1.00 1.00 2.00 2.00 2.00 2.00 2.50 2.50
Dimension A
mm 25.4 25.4 25.4 50.8 50.8 50.8 50.8 63.5 63.5
Inches 1.00 1.00 1.00 2.00 2.00 2.00 2.00 2.50 2.50
Dimension B
mm 25.4 25.4 25.4 50.8 50.8 50.8 50.8 63.5 63.5
Inches 4.12 4.12 4.12 7.12 7.12 7.12 7.12 6.19 6.19
Dimension C
mm 104.6 104.6 104.6 180.8 180.8 180.8 180.8 157.2 157.2
Inches 8.70 8.70 8.70 9.00 9.00 9.00 9.00 7.65 7.65
Dimension D
mm 221 221 221 228.6 228.6 228.6 228.6 194.3 194.3

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 14
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Protection - Gauges

ROTRON has a variety of gauges for pressure,


vacuum and temperature measurements in Pressure Vacuum
various ranges. These gauges are reliable and 80

rugged.
100
60
3

12
2 PRESSURE 4

0
40
SPECIFICATIONS:

140
1 5

Pressure/ Vacuum Temperature

20

16
0 6

CASE – Drawn Steel Finished CASE – Steel

0
0
P S I
ER
in Black Enamel LENS – Glass
I NC
HE S OF WAT

DIAPHRAGM – ACCURACY– 1%
Bronze LENS – Clear WEIGHT – 1/4 lb.
Plastic ACCURACY– CONNECTION – 1/2"
2%WEIGHT – 1/2 lb. NPT FACE – 3" Dial
CONNECTION – 1/4"
NPT FACE – 2 1/2" dia.

3.38 ±.12

100 120
2.50 ±.06
80
200 .25 ±.03

14
250

0
Ø 3.18 ±.12
150 300

60

160
100 350

40

180
50 °F 400

20
0
10 20
1/2 NPT CONNECTION
°C

Temperature

Part/Model Number

Specification Units 551376 271949 529428 271950 551368

Range - Pressure Pressure Vacuum Vacuum Temperature


Description - 0-60 IWG 0-160 IWG 0-60 IWG 0-160 IWG 0-200 Deg C

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 15
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
System - Variable Frequency Drive
A Variable FrequencyDrive (VFD)is an adjustable speedAC motor control designed to speed the
blower RPMup or down. Our VFDsare designed to minimize losses and deliver increased
efficiency, low maintenance, and the long life expected from the ROTRON product line.

FEATURES

ncy by controlling motor RPMs
• Accepts 3Ø or 1Ø inputs to drive 3Ø motor blower
assemblie
• Accepts
s 4-20 mA, 0-5 VDC or 0-10 VDC inputs for
system automation control and intregation
• Provides dynamic breaking capabilities
• Replaces motor starter function
• Digital readout in either Hz or RPMs
• Keypadenclosure(NEMA4X-Indoor) vsn be
mounted up to 100' from controller with cable
assembly option
SYSTEM REQUIREMENTS
• In cases where the distance between the controller
and motor exceed 50', the use of a line reactor on
load side is needed.
• XP motors must be UL listteedd for use with a
Variable Frequency Drive.
VARIABLE FREQUENCY DRIVE SELECTION
Thereare some common guidelines in sizing a VFDfor use on a AMETEKROTRONblowers such as the allowable
speed(table 1) for a given motor type. To determine the required RPM to achieve a desired flow and pressure
form a specific bloewr, turn to the blower performance at variable speeds in section E of this catalog. The
required RPM must fall within the allowable rate of the motor being used.
Table 1
Motor Allowable Turndown Allowable Speedup
Standard 3600 RPMto 1800 RPM —
3600 RPMto 900 RPM —
Inverter Motor 3600 RPMto 360 RPM* 3600 RPMto 7200 RPM
* Turndown of 10:1 is not typically done with regenerativeblower designs.
For all applications above 3600 RPM, contact your Field Sales Engineer for proper horsepower sizing.

Specification

Model Number Part Number Description


IV101AE58 551529 115/1, Up to 0.5 HP, DR068-DR303
IV102AE58 551530 230/1, Up to 0.5 HP, DR068-DR303
IV101AL58 551531 115/1, 0.75 to 1.0 HP, DR353-DR404
IV102AL58 551532 230/1 or 3, 0.75 to 1.0 HP, DR353-DR404
IV103AL72 551533 460/3, 0.75 to 1.0 HP, DR353-DR404
IV102AS58 551534 230/1 or 3, 1.5 to 2.0 HP, DR454-DR505
IV103AS72 551535 460/3, 1.5 to 2 HP DR454-DR505
IV102K58 551536 230/1 or 3, 2.5 to 3 HP, DR505-DR555
IV103K72 551537 460/3, 2.5 to 3.0 HP, DR505-DR555 230/1
IV102D58 551538 or 3, 3.5 to 5 HP, DR555-DR808D 460/3,
IV103D72 551539 3.5 to 5 HP DR555 to DR808D 230/3, 5.5
IV152AY58 551540 to 7.5 HP, DR808-DR858 460/3 5.5 to 7.5,
IV152AY72 551541 DR808 – DR858
IV152BB58 551542 230/3, 8 to 10 HP, DR858-DR909
IV153BB72 551543 460/3, 8 to 10 HP, DR858-DR909
IV152BC58 551544 230/3, 10.5 to 15 HP, DR909
IV153BC72 551545 460/3, 10.5 to 15 HP, DR909
IV152BH58 551546 230/3, 15.5 to 20 HP, DR9, DR14BH
IV153BH72 551547 460/3, 15.5 to 20 HP, DR9, DR14BH
IV152BP58 551548 230/3, 20.5 to 30 HP, DR13, DR14
IV153BP72 551549 460/3, 20.5 to 30 HP, DR13, DR14
IV152BQ58 551550 230/3, 30.5 to 40 HP, DR15
IV153BQ72 551551 460/3, 30.5 to 40 HP, DR15
IV153ED72 551552 460/3, 50.5 to 60 HP, DR15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 16
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
System - Air Knives

SINGLE-ENDED SIDE VIEW* DOUBLE-ENDED SIDE VIEW**

L L

2.5"-8 NPT CL CL 2.5"-8 NPT CL CL


(TYP) (TYP)

3.15 3.15
TYP. TYP.
.25-20 UNC X .75 LG

CAPPED END VIEW


* Air knives 30" and smaller 4.58
MOUNTING VIEW RAIL 2.2 GAP SETTING
(REF) PER MODEL
1.75
2.2
0.75 CL CL CL
4.58

.25-20 UNC THRU


1.0 S
TYP.

Part/Model Number

AK06S060 AK12S060 AK18S060 AK24S060 AK30S060 AK36S060 AK42S060 AK48S060 AK54S060 AK60S060

Specification Units 523489 552955 522949 553000 522950 523492 523493 523494 523495 523496
Inches 9.30 15.30 21.30 27.30 33.30 42.30 48.30 54.30 60.30 66.30
Length (L)
mm 236.2 388.6 541 693.4 845.8 1074.4 1226.8 1379.2 1531.6 1684
Inches 6 12 18 24 30 36 42 48 54 60
Slot Length
mm 152.4 304.8 457.2 609.6 762 914.4 1066.8 1219.2 1371.6 1524
Inches 4.00 10.00 16.00 22.00 28.00 17.00 20.00 23.00 26.00 29.00
Dimension S
mm 101.6 254 406.4 558.8 711.2 431.8 508 584.2 660.4 736.6

The ROTRON air knife is located at a strategic


Air Knives point in your assembly line conveyor belt
An Oil-free Blowing and Drying System area. Air flows from the blower into the air
Custom-fit for Your Application knife, where a sheet of air is directed out
through a proprietary linear nozzle design
FEATURES: onto assembly line parts. The opening can
• Lightweight aluminum plenum and rail, steel end cap, be altered to adjust the air-flow rate, thus
and cast-iron NPT flanges varying blow-off velocity to meet your
• Engineered, extruded design to achieve 95% efficiency application requirements.
• Adjustable slot (pre-set at 0.060") to control velocity
from 5000-35000 fpm
• Custom cut lengths to fit system restraints
• Oil-free and lower cost alternative to compressed air for
blow-off, solution blow-back, and drying applications
OPTIONS:
• Chemical resistant designs utilizing Chem -Tough TM
chemically resistant surface conversion, stainless steel
hardware, and nickel plated end caps and flanges
• Food processing grade designs utilizing Food -Tough TM
sanitary treatment surface conversion, stainless steel
hardware, and nickel plated end caps and flanges
• Deionizers for sterile environments available
• Mirror image single-ended models for above and below
conveyor operation

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 17
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
System - Air Knives

Precision Cleaning Air Knife and Blower Selection Chart


18" 24" 48" 40,000 FPM
6" 12" knife 30" 42" 54"
knife knife knife
knife knife knife 36" knife
knife 60"
knife

DRP9 35,000 FPM


DR858
DR808
DRP15
DR757 DR909

Air Velocity
30,000 FPM
DR656

25,000 FPM
DRP13

20,000 FPM
DR14

DR979 15,000 FPM

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 18
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
System - 5 Way, 3 Port, 2 Position Diverter Valve

SPECIFICATIONS:
• Aluminum body and spool assembly
• 303 stainless steel shaft
• 115 V-60 Hz solenoid valve air
OPTIONS
• Corrosion resistant surface treatments
• International voltage and frequency (Hz)
• Application specific designs
DR 505 BLOWER WITH DIVERTER VALVE
These unique solenoid actuated diverter valves The principle behind ROTRON’s diverter valve system is a
automatically change air piping from pressure to simple one: Some applications such as vacuum part pick-up, air
suction; greatly enhancing blower versatility and tables, and pneumatic tube systems require both vacuum and
productivity. This valve is effective in blower pressure in their equipment’s operation, but not simultaneously.
applications that require frequent switching from They eliminate the need for two sep-arate blowers, and
pressure to suction and vice-versa. They are cost elaborate valving system, or cycling/reversing a spinning
effective as applications normally requiring two blower impeller. ROTRON’s diverter valve changes the air
blowers and/or intricate piping systems may be passageways. By utilizing the side vent ports for incoming or
accomplished with one blower. outgoing air, the equipment/piping side of the valve changes
Diverter valves may be purchased as blower/valve from vacuum to pressure and back again by a signal sent to the
assemblies, or as separate stand-alone valve solenoid coil.
assemblies for use in other switched air applications.

Part/Model Number

Specification Units 515554 037435 037482


Description - DR404, DR454, DR505 DR6, DR808, DR858 DR6, DR808, DR858
Ref Blower Model - Small Large Large
Piping Flange - Threads Threads Threads
Blower Flange - Face Threads Face
Inches 7.65 9.25 9.25
Dimension A
mm 194.3 235 235
Inches 14.22 23.39 23.39
Dimension B
mm 361.2 594.1 594.1
Inches 7.14 10.93 10.93
Dimension C
mm 181.4 277.6 277.6
Inches 2.50 3.55 3.55
Dimension D
mm 63.5 90.2 90.2
Inches 5.00 7.10 7.10
Dimension E
mm 127 180.3 180.3
Inches 1.50 2.50 2.50
Dimension F
mm 38.1 63.5 63.5
Inches 1.50 2.50 2.50
Dimension G
mm 38.1 63.5 63.5

Blower
BLOWER SIDE Blower

D C
IN OUT IN OUT

E WORKING
G PART
A

SOLENOID SOLENOID

F SUCTION PRESSURE
B
"PRESSURE" AIR PATH "SUCTION" AIR PATH
EQUIPMENT/PIPING SIDE ISO VALVE DRAWING DE-ENERGIZED POSITION ENERGIZED POSITION
Consult factory for proper selection and application.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 19
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
System - 5 Way, 3 Port, 2 Position Diverter Valve

ROTRON RELEASED BLOWERS WITH DIVERTER VALVE MOUNTED


Model * Part No. Mounted Components
Manifold
Diverter Valve
DR353BR58MV 080757
DR404AL72MV 037749 517077
DR404AL58MV 037715
DR454R72V 037605 515554
529397
DR454R58V 037122
DR505AS72MV 037709
DR505AS58MV 037554
517459 DIVERTER VALVE MANIFOLD
DR808AY72WV 080084
037482 550667
DR858BB72WV 080085

• Models listed below include


diverter valve and manifold.

Blower Model Reference Key


A = SPIRAL E = DR/EN/CP 656, 6, 633, S7
B = DR/EN/CP 068, 083, 101, 202 F = DR/EN/CP 757, 808, 858, S9, P9 (Inlet Only)
C = DR/EN/CP 303, 312, 313, 353 G = DR/EN/CP 833, S13, P13 (Inlet Only)
D = DR/EN/CP 404, 454, 513, 505, 555, 523 H = DR/EN/CP 909, 979, 1233, 14, S15, P15 (Inlet Only)

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 20
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Accessories
Pressure & Vacuum Arrangements

Pressure or vacuum guages should be located in the delivery Failure to observe these precautions can result in false
line, oriented as shown. Assure that the guage is approxi- readings of guages and failure of the relief mechanism to
mately three pipe diameters from the blower delivery flange protect the blower from overload.
and that the relief valve is located at the same spacing from
the guage. 90° elbows should be located at least five pipe In order to avoid overheating or distortion of PVC pipe,
diameters from the blower delivery flange. Elbows, taps, tees, the first five to eight feet from the blower delivery flange
valves, or other restrictions to air flow should not be located on pressure systems should be metal.
between the blower delivery flange and accessories described
above.

Typical Pressure System

Typical Vacuum System

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 G 22
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Motor Options Standard Motor Variations

ROTRON strives to provide the most complete variety of desired Chemical Processing (CP) features are added to TEFC, XP or HiE
options on our products including on our motors. By using designs for corrosive gas service, Marine Duty service and
motor vendors of high quality and versatility, we can provide sanitary (food/pharmaceutical) service.
motor features from multiple released designs to meet your
needs (i.e., a Chem Processing Inverter Duty Explosion-proof • 303 stainless steel shaft
motor with space heaters and drains wound for 380 V-50 Hz
service). • Cast iron and steel frame epoxy painted or zinc plated

Design Consistency • Zinc plated hardware

ROTRON motors are engineered for us to integrally mount with • Stainless steel nameplate
our blower and maximize blower performance. Our vendors are
qualified by ROTRON (per motor part number) to ensure the • Non-hygroscopic insulation; double dipped and baked stator
blowers’ mechanical and electrical needs merge with your
required features. The basic motor requirements on our • Epoxy coating on rotor
DR/EN/CP/HiE products include:
• Gaskets and joint sealers on all metal-to-metal surfaces
• NEMA approved
• Oversized conduit box
• CE conformity (non-XP models)
High Efficiency (HiE) features are added to TEFC, ODP, XP or CP
• UL & CSA approved with symbol and file on nameplate motors for maximum motor efficiency and life. ROTRON HiE
motors carry extra phase-to-phase protection for use with
• C-face mount inverters between a 1750-3500 RPM range.

• Permanently sealed bearings Inverter Duty features are added to TEFC, ODP, XP or CP for use
with Inverters/Variable Speed Drive Controllers. A wide range
• Shaft end play, run out and perpendicularity requirements of RPM can be handled and should be specified at time of
above NEMA standards quote. For best compatibility, an inverter should be matched to
the motor manufacturers design.
• Dual voltage and dual frequency (some models not feasible)
to maximize use worldwide Project Specific Motor Variations

• Single Shafted Totally Enclosed Fan Cooled (TEFC) and There are no limits to the options you can select or request for
Explosion-proof (XP) models your product. Routine motor options include:

• Double Shafted Open Drip Proof (ODP) models with dual • International voltage & frequency (Hz)
internal fans for circulation
• Different shaft material
• Class I Group D minimum on explosion-proof motors; many
are Class I Group D, Class II F & G • Oversized and/or Nema 4 intent T-box

• Commercial Spa (SPA-ODP) motors with automatic thermal • Space heaters


overload protection and industry specified terminal strip
• Drains

• Regreasable bearings

• Tropicalized windings

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Typical Sealing Options

Lo-Leak™ LIP SEAL Option

The Lo-Leak™Lip Seal option is available to control


gas leakage for all DR models and is standard on
all EN and CP models. Features include: Lip seals
to prevent leakage at the motor shaft. RTV sealing
compound is used to cut off all leakage paths at
the blower’s metal-to-metal surfaces. Castings are
vacuum impregnated to prevent leakage through
castings. Estimate leakage rate = 25 cc/min or less

Double Face Carbon Seal Option

For further minimization of gas leakage on all DR, EN and CP


models, a pair of face seals work against each other on opposite
sides of a common mating ring to effectively reduce gas leakage
at the motor shaft. The face shields are continually lubricated
from a reservoir to prolong seal life. The seal is completed by
installing the blower to motor bolts with O-rings and sealing
the covers to the housing with an RTV sealing compound.
O-rings are also placed between the pipe flanges and the
manifold.
All castings are vacuum impregnated.
Estimate leakage rate = 0.5 cc/min or less

Hermetically Sealed Spiral Containment Option

The containment option utilizes a series of O-rings to control gas leakage in Spiral blower models. The O-rings are placed at critical
locations on the blower’s housing and covers to contain gas leakage.

Hermetically Sealed Mag Drive Option

On DR, EN and CP 101 units, a magnet drive option has been an alternative for complete gas containment.
O-rings are used throughout the product, and magnets attached to the motor shaft spin magnets inside the blower without shaft
penetration. Estimated leakage rate = 0.001 cc/mi
Nitrogen Purge / Blanket Option

The nitrogen purge option is a carrier designed to accept a nitrogen line which will purge the space outside the shaft hole. Purges can
be designed to bleed the nitrogen into the process called a blanket, or the carrier can have a second tap to carry away the leaking
contaminants.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Chem-Tough™ Chemical Resistance Chem-Tough™ at Work

To stand up in corrosive and hazardous environments, chemical Chem-Tough™ employs the advantages of anodizing, hardcoat
processing blowers have to be tough. That’s why Ametek plating, low-friction polymers and dry lubricants to become an
ROTRON routinely applies Chem-Tough™, ROTRON’S own integral part of the blower’s molecular structure.
engineered and proprietary process, whenever it builds
blowers for handling chemical (vapor) streams. Chem-Tough™ Specifically, Chem-Tough™ first converts the aluminum surface
combines the advantages of aluminum oxide ceramic and to aluminum oxide, forming a new ceramic-like surface. The
selected fluorocarbons to give ROTRON blowers unheard-of water in the ceramic is replaced with Teflon®, adding a multi-
levels of chemical resistance, hardness, abrasion resistance, functional dimension to the surface; in the process, the
permanent lubricity and more. aluminum crystals expand and form anchor crystals that
remain hygroscopic for a short time. Then, under controlled
Chem-Tough™ Brings You the Rotron Advantage conditions, particles of the specified polymer are infused to
interlock with these anchor crystals. The new surface extends .5
Through this unique proprietary process, Chem-Tough™ gives mil above and below the original aluminum surface – and
ROTRON blowers these advantages: forms a permanent molecular bond with the metal.

• Outstanding Chemical Resistance The result: a plastic/ceramic surface that’s harder than steel, is
Time after time, Chem-Tough™ finishing shows extremely high continuously lubricating, and resists damage from chemicals
resistance to most common chemicals, as well as dramatically like no other. The kind of protection you need for your
improved corrosion resistance over regular hard anodizing. chemical processing blowers.
Chem-Tough™ allows aluminum to achieve equivalent
corrosion resistance as teflon®. 90-day immersion in acid or
alkaline solution (pH 4.0-8.5) has no effect; neither does
prolonged exposure to salt water. Far exceeds military
specification requirements for salt spray.

• Abrasion Resistance Equivalent to Steel


Excellent for smooth surfaces, Chem-Tough™ surface
conversion provides higher wear resistance than either
case-hardened steel or hard-chrome plate. Rub any other
metal against the Chem-Tough™ finish, and the metal will
show nothing but the slightest wear. Chem-Tough™ provides
a perfect bond to the parent metal.

• Increased Hardness
With an equivalent hardness of Rc 40-60, Chem-Tough™ is
approximately file-hard – the hardness of nitrated steel.
Because the Chem-Tough™ surface becomes an integral part
of the metal, it simply cannot peel or chip – neither can it be
scratched, flaked or nicked under ordinary conditions.

• Permanent Dry Lubricity


By infusing polymers into aluminum, Chem-Tough™ gives the
resulting surface a high degree of permanent lubricity and
resistance to moisture. The polymers also level off surface
asperities, significantly reducing surface tension. The result:
blowers converted with Chem-Tough™ have a longer life,
operate more efficiently and call for less maintenance.

• Other Proprietary Processes


Food-Tough™ uses the same unique process as Chem-Tough™,
and is designed for the food processing, medical and
pharmaceutical markets. Food-Tough™ has USDA approval
and meets FDA guidelines.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Chemical Resistance Chart


Chemical Effect Ratings

Chem-Tough (Teflon®)

Chem-Tough (Teflon®)
A – No effect – acceptable

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel
B – Minor effect – acceptable
C – Moderate effect – questionable

Carbon Steel

Carbon Steel
D – Severe effect – not recommended

Hastelloy C

Hastelloy C
Aluminum

Aluminum
Cast Iron

Cast Iron
* – Not tested

Chemical Chemical
Acetaldehyde B * C A A A A * A Barium Carbonate B B B A B A A A A
Acetate Solv. B B A A A B A B * Barium Chloride D D C A C A A A A
Acetic Acid B D C A * B A B A Barium Hydroxide D C C A B C A A B
Acetic Anhydride B B D A B A A B A Barium Sulfate D C C A B A A A A
Acetone A A A A A A A B A Barium Sulfide D C C A B A A * *
Acetylene A A A * A A A A * Benzaldehyde B B A A A A A * A
Acrylonitrile B C * * A A C * B Benzene B B C A B A A A B
Alcohols Benzoic Acid B D * A B A A A A
Amyl C C C A A A A * A Benzol B * * A * A A * A
BENZYL B * * * * A A * A Borax (Sodium Borate) C A C A * A A A A
Butyl B C C A A A A * A Boric Acid B D * A B A A A A
Diacetone A * A * * A A * A Bromine (Wet) D D D A D D D D A
Ethyl B A A * * A A A A Butadiene A C C A A A A * *
Hexyl A * A * * A A * A Butane A C C A A A A * *
Isobutyl B * A * * A A * A Butanol A * * A * A A * A
Isopropyl B C A * * A A * A Butylene A A A A A * A * *
Methyl B A A A * A A A A Butyl Acetate A * A A * * C * A
Octyl A * A * * A A * A Butyric Acid B D * A B B A A A
Propyl A * A A * A A * A Calcium Bisulfate D D * A C D A * *
Aluminum Chloride 20% B D A * * D C D A Calcium Bisulfide C * * A * * B * A
Aluminum Chloride D D B A C D C * A Calcium Bisulfite C * * A * D A * A
Aluminum Hydroxide A D A A * A A A * Calcium Carbonate C D * A B A A A A
Alum Potassium Calcium Chloride C C * A C A D C A
Sulfate (Alum), 10% A D A A * A * * B Calcium Hydroxide C * * A B A A * A
Alum Potassium Calcium Hypochlorite C D * A D A C C B
Sulfate (Alum), 100% B * A A * D A B B Calcium Sulfate B * * A B A A A B
Aluminum Sulfate A D A A * C C A A Carbon Bisulfide A B * * B A A A *
Amines A A B A A A A * A Carbon Dioxide (Wet) C C * A * A A * A
Ammonia 10% * * * A * * A * A Carbon Disulfide C B C A * B A * *
Ammonia, Anhydrous B D B A A B A A A Carbon Monoxide A * * * * A A * *
Ammonia, Liquids D A A A * A A A B Carbon Tetrachloride C C D A B C B A A
Ammonia, Nitrate C * A * * A A A * Carbonated Water A D * * B A A A *
Ammonium Bifluoride D * * * * C A * B Carbonic Acid A D * A B A B A A
Ammonium Carbonate C C B A B A A A B Chloracetic Acid C D * A D D D D A
Ammonium Chloride C D D A C A C A A Chlorinated Glue D D * * * A A * *
Ammonium Hydroxide C A C A A A A A A Chlorine, Anhydrous Liquid D C * A * D D D A
Ammonium Nitrate B A D A A A A A A Chlorine (Dry) D A * A B A A * A
Ammonium Persulfate C D A A * A A A A Chlorine Water D D * A D * D * B
Ammonium Phosphate, Dibasic B * D A B A A A A Chlorobenzene (Mono) B B C A A A A * A
Ammonium Phosphate, Monobasic B * A A * A A A A Chloroform D D C A A A A A A
Ammonium Phosphate, Tribasic B C D A B A A A A Chlorosulfonic Acid D * D A D D * D B
Ammonium Sulfate B C C A C A B A A Chlorox (Bleach) C D C A * A A * A
Amyl-Acetate B * C A B A A C A Chromic Acid 5% C D * * * A A B A
Amyl Alcohol B * A A * A A * A Chromic Acid 50% C D * A C B B * A
Amyl Chloride D * A A * C B * A Citric Acid C D * A * A A A A
Aniline C * C A B A A A B Citric Oils C * * * * A A * *
Anti-Freeze A B C A * A A * A Copper Chloride D D * A C D D B A
Antimony Trichloride D * * A * D D * A Copper Cyanide D D * A * A A A A
Aromatic Hydrocarbons A A A * * * A * * Copper Floborate D D * A * D D * B
Arsenic Acid D D D A B A A * * Copper Nitrate D * * A B A A B A

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H4
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Chemical Resistance Chart (Cont’d)


Chemical Effect Ratings

Chem-Tough (Teflon®)

Chem-Tough (Teflon®)
A – No effect – acceptable

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel
B – Minor effect – acceptable
C – Moderate effect – questionable

Carbon Steel

Carbon Steel
D – Severe effect – not recommended

Hastelloy C

Hastelloy C
Aluminum

Aluminum
Cast Iron

Cast Iron
* – Not tested

Chemical Chemical
Copper Sulfate (5% Solution) D D * A * A A A A Hydrofluoric Acid 100% D D D A D D D * B
C re s ols B * * * * A A * * Hydrofluosilicic Acid (20%) D D * A * D D * B
C re s ylic A c id C * * A B A A * B Hydrofluosilicic Acid C * * A * D D * C
C yc lohe x a ne A * A * * A * * * Hydrogen Gas A B B A A A A * *
D e te rge nts A * A * * A A * * Hydrogen Peroxide 10% A D * A * C C * A
D ie s e l F ue l A A A * A A A * * Hydrogen Peroxide A D D A * A B A A
D ie thyla mine A * * A A A * * * Hydrogen Sulfide,
D ye s B * * * * A A * * Aqueous Solution C D * A * A A C A
Epsom Salts (Magnesium Sulfate) A * * * B A A A B Hydrogen Sulfide (Dry) D B B A A C A * A
E tha ne A * * * A A * * * Hydroxyacetic Acid (70%) D * * * * * * * *
E ther A * B * A A A A B Ink C D D * A A A * *
E thyl A c e ta te B * C A * A A * B Iodine D D * A * D D D B
E thyl C hloride B C D A * A A A B Iodoform A C B A B D A * *
Ethylene Chloride C C C A * A A * B Isotane A * * * * * * * *
Ethylene Dichloride D * C A * A A * B Isopropyl Acetate C * * * * * B * *
Ethylene Glycol A B C A * A A * A Isopropyl Ether A * A A A * A * *
Ethylene Oxide A * * A * * A * * Jet Fuel (JP3, JP4, JP5) A A A A A A A * *
F a tty A c ids B D * A * A A * A Kerosene A A B A A A A A A
F e rric C hloride D D * A * D D D B Ketones B A A A A A A * A
Fer ric Nit rate D * * A * A A A A Lacquers A C C * A A A * *
F e rric S ulfa te D D * A * A C A A Lactic Acid C D D A A A B C A
Ferrous Chloride D D * A * D D * B Lead Acetate D * D A B A A * A
Ferrous Sulfate D D D A B A C * B Lubricants A * * A * A A * A
F luorine D D D C D D D * A Magnesium Chloride D D C A B B B A A
F luos ilic ic A c id D D * A * * B * B Magnesium Hydroxide D B B A A A A * A
F orma lde hyde A D A A A A A * B Magnesium Sulfate B C B A B B A * B
F ormic A c id D D D A C A B B A Maleic Acid B * B A C A A A A
F re on 11 B C B A A * A * * Malic Acid C * D A B A A * A
Freon 12 (Wet) B * * A * * D * * Mercuric Chloride (Dilute Solution) D D D A D D D D B
F re on 2 2 B * * * * * A * * Mercuric Cyanide D * D A A A A * *
F re on 11 3 B * * * * * A * * Mercury C A A A A A A A A
F r e o n T. F . B * * * * * A * * Methane A A A A A A A A A
F ue l O ils A C B A A A A * A Methyl Acetate A * B A A * A * A
F ura n R e s in A A A A * A A * * Methyl Acetone A A A A A * A * *
F urfura l A * A A A A A * B Methyl Alcohol 10% C * B A A * A * A
G a llic A c id A D D A B A A * A Methyl Butyl Ketone A * * * * * A * *
G a s oline A A A A A A A A A Methyl Cellosolve A * * * * * * * *
G lyc e rine A B B A A A A A A Methyl Chloride D * * A * C A * A
H e pta ne A * B A A * A * A Methyl Ethyl Ketone A * * A * A A * A
H e x a ne A * B A A A A * A Methylamine A B B * A * A * *
Hydraulic Oils (Petroleum) A A A A A A A * * Methylene Chloride A * B A A A A * A
Hydraulic Oils (Synthetic) A A * * * A A * * Naptha A B B A A A A A A
Hydrobromic Acid D D D A D D D D A Napthalene B B A A B A B * A
Hydrochloric Acid (Dry Gas) D * D A D C A * A Nickel Chloride D D * A * A B * A
Hydrochloric Acid (20%) D D * A * D D D B Nickel Sulfate D D D A B A B * B
Hydrochloric Acid (37%) D D * A * D D D B Nitric Acid (10% Solution) D D D A A A A A A
Hydrochloric Acid 100% D D * A * D D * C Nitric Acid (20% Solution) D D * A * A A A A
Hydrocyanic Acid A * C A A A A C A Nitric Acid (50% Solution) D D * A * A A A A
Hydrofluoric Acid (20%) D D * A * D D D B Nitric Acid
Hydrofluoric Acid (75%) D D * A * C D * C (Concentrated Solution) B D * A * D B A B

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Motor Blower Options

Chemical Resistance Chart (Cont’d)


Chemical Effect Ratings

Chem-Tough (Teflon®)

Chem-Tough (Teflon®)
A – No effect – acceptable

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel

302 Stainless Steel


304 Stainless Steel
316 Stainless Steel
440 Stainless Steel
B – Minor effect – acceptable
C – Moderate effect – questionable

Carbon Steel

Carbon Steel
D – Severe effect – not recommended

Hastelloy C

Hastelloy C
Aluminum

Aluminum
Cast Iron

Cast Iron
* – Not tested

Chemical Chemical
Nitrobenzene C B B A B A B * B Sodium Hydrosulfite A * * A * * * * A
Oleum B * B A B * A * * Sodium Hydroxide (20%) D A * A * A A A A
Oxalic Acid (cold) C D D A C A B A B Sodium Hydroxide (50% Solution) D B * A * A B * A
Pentane A B B A A C C * B Sodium Hydroxide (80% Solution) D C * A * A D * B
Perchloroethylene A B B A B A A * * Sodium Hypochlorite (to 20%) D C * A * A D * B
Petrolatum B C C A A * A * * Sodium Hypochlorite D D D A D * A * A
Phenol 10% A B D A B A A * B Sodium Hyposulfate D * * A * A A * *
Phenol (Carbolic Acid) B D D A B A A A A Sodium Metaphosphate A B B A A * A * *
Phosphoric Acid Sodium Metasilicate B C C A A * A * *
(to 40% Solution) D D * A * B A A A Sodium Nitrate A A B A B A A A B
Phosphoric Acid Sodium Perborate B B B A B * C * *
(40%-100% Solution) D D * A * C B B A Sodium Peroxide C D C A B A A * B
Phosphoric Acid (Crude) D D D A * D C C A Sodium Polyphosphate
Phosphoric Anhydride (Molten) D * * A * A A * * (Mono, Di, Tribasic) D * * A * A A * A
Photographic (Developer) C D * * * C A C A Sodium Silicate C * B A B A B A B
Phthalic Anhydride B C C A B A B * A Sodium Sulfate B A B A B A A C B
Picric Acid C D D A B A A * A Sodium Sulfide D A B A B A B * B
Potash C B * * * A * A A Sodium Sulfite C A * A * C C * A
Potasium Bicarbonate C D * A * A * B B Sodium Thiosulphate (“Hypo”) B C B A A A A * *
Potassium Bromide C D D A A A * B B Stannic Chloride D D D A D D D * B
Potassium Carbonate C B B A B A * A A Stannous Chloride D D D A D D C * A
Potassium Chlorate B B B A B A A A B Stearic Acid B C C A B A A A A
Potassium Chloride B B B A C A A B A Stoddard Solvent A B B A A A A A A
Potassium Chromate A A * * * * B B B Styrene A * A A A A A * *
Potassium Cyanide Solutions D B B A B A B A A Sulfate Liquors B * * * * C C * A
Potassium Dichromate A B C A B A A A B Sulfur Chloride D * * A * D D D *
Potassium Ferrocyanide C * C A B A * A B Sulfur Dioxide A * * A * A A C B
Potassium Hydroxide (50%) D C A A A B B B A Sulfur Dioxide (Dry) A A B A A A A * A
Potassium Nitrate B * B A B A B A B Sulfur Trioxide (Dry) A B B A A A C * *
Potassium Permanganate B B B A B A B B B Sulfuric Acid (to 10%) C D * A * D C C A
Potassium Sulfate A B B A B A B B A Sulfuric Acid (10%-75%) D D * A * D D D B
Potassium Sulfide B B B A A A * A B Sulfurous Acid C D D A C C B C B
Propane (Liquified) A * B A A A * A * Tannic Acid C C C A B A A A B
Propylene Glycol A B B A B B * A * Tanning Liquors C * * A * A A * A
Pyridine B B A A * C * B * Tartaric Acid C D D A B A B B B
Pyrogallic Acid B B B A B A A A A Tetrahydrofuran D D A A * A A * *
Silver Bromide D * * * * C C B * Toluene, Toluol A A A A A A A * A
Silver Nitrate D D D A B A B A A Trichlorethane C C * A * C A * A
Sodium Acetate B C C A B A A B A Trichlorethylene B C B A B A A * A
Sodium Aluminate C * C A B * * A B Water, Acid, Mine C C * * * A A * *
Sodium Bicarbonate A C C A B A A A * Water, Distilled, Lab Grade 7 B D * A * A A * *
Sodium Bisulfate D D D A A A * A B Water, Fresh A B D A A A A * *
Sodium Bisulfite A D * A * A * A B Water, Salt B D * * * A A * *
Sodium Borate C C C A B A * A A Weed Killers C * * * * A A * *
Sodium Carbonate C B B A B A B B A Whiskey and Wines D D D A A A A A *
Sodium Chlorate B * C A B A * A B Xylene A A B A A A A * A
Sodium Chloride C B C A B A C B A Zinc Chloride D D D A D A B B B
Sodium Chromate D B B A A A A * B Zinc Hydrosulphite D D * * * * A * *
Sodium Cyanide D B B A B A * A * Zinc Sulfate D C D A B A A A B
Sodium Fluoride C D D A B C * C A

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 H6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Throughout our catalog, you will find terminology used for air moving selection and product sizing. Below are a few of the key terms:

Flow Specific Gravity

• Volume Rate/Time • Density Ratio Relative to Air


• ROTRON charts are in SCFM, m3/min, or L/S • Standard Air SG = 1.0
• SCFM = Standard Cubic Feet Per Minute (American) where • Methane SG = 0.55
temperature = 68°F, • See Specific Gravity Chart for other gases on pg. I-4
air density = 0.075 lb/cubic foot,
and altitude = 0 feet above sea level Velocity
• M3/min = Cubic Meters Per Minute (Metric)
• L/sec = Liters Per Second (Metric) • Distance/Time or Flow/Area
• 1 m3/min = 35.3 SCFM • FPM = Feet Per Minute (American)
• 1 L/sec = 2.119 SCFM • MPH = Miles Per Hour (American)
• See Standard Engineering Conversions for other flows on • M/min = Meters Per Minute (Metric)
pg I-2. • Km/h = Kilometers Per Hour (Metric)
• 88 FPM = 1 MPH
Pressure • 26.82 M/min = 1 MPH
• 1.609 Km/h = 1 MPH
• Force/Area • See Standard Engineering Conversion Chart for other
• ROTRON charts are in IWG, PSIG, MM of Water, IHG, or mbar velocities on pg. I-2
• IWG = Inches of Water Gauge (American) • See Orifice Flow Calculation Chart for air flow equations on
• PSIG = Pounds Per Square Inch Gauge (American) pg. I-7
• MM of Water = Millimeter of Water Gauge (Metric)
• IHG = Inches of Mercury Gauge (American)
Pressure Drop / Back Pressure / Impedance
• mbar = Millibar Gauge (Metric)
• PSIA = Pounds Per Square Inch Absolute (American)
• Friction causes air to slow down and lost energy is measured
• 27.7 IWG = 1 PSIG
in pressure drop terms
• 703.58 MM of Water = 1 PSIG
• Typical pressure drop areas include piping, elbows,
• 2.036 IHG = 1 PSIG
accessories and system
• 0.069 Bars = 69 mbar = 1 PSIG
• Each fixed system has a fixed system impedance caused by a
• Standard Atmosphere = 0 PSIG = 14.7 PSIA
single or multiple pressure drop points
• See Basic Fan Laws Chart for correcting pressure due to speed
• Changing the system impedance will cause blowers work
or density changes on pgs. I-5 and I-6
point to change
• Changing the blower with fixed system impedance will
Density change the working back pressure
• See Friction Loss Per Foot of Tubing and Fitting Charts on
• Weight/Volume pg. I-8
• Standard Air = 0.075 lb/cubic foot
• See Density Chart for other gases on pg. I-4
• See Density Correction Chart due to altitude and temperature
changes on pg. I-3

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I1
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Standard Engineering Conversion


MULTIPLY BY TO OBTAIN MULTIPLY BY TO OBTAIN
Atmospheres 76.0 Cms. of Mercury KGS./Cubic Meter 0.06243 Pounds/Cubic Foot
Atmospheres 29.92 Inches of Mercury Kilometers 3281 Feet
Atmospheres 33.90 Feet of Water Kilowatts 56.92 British Thermal Units/Min.
Atmospheres 10,333 Kgs./Sq. Inch Kilowatts 737.6 Foot-Pounds/Sec.
Atmospheres 1.013 x 105 Pascals Kilowatts 1.341 Horsepower
Atmospheres 14.70 Pounds/Sq. Inch Kilowatts 14.34 Kg.-Calories/Min.
Atmospheres 760 Torrs Kilowatt-Hours 3415 British Thermal Units
Bars 0.9869 Atmospheres Liters 103 Cubic Centimeters
Bars 1. x 106 Dynes/Sq. Cm. Liters 61.02 Cubic Inches
Bars 1.020 x 104 Kgs./Square Meter Liters 10-3 Cubic Meters
Bars 14.50 Pounds/Sq. Inch Log10N 2.303 LogEN or Ln N
British Thermal Units 0.2520 Kilogram-Calories Log N or Ln N 0.4343 Log10N
British Thermal Units 777.5 Foot-Pounds Meters 100 Centimeters
British Thermal Units 3.927 x 10-4 Horsepower-Hours Meters 3.2808 Feet
British Thermal Units 1054 Joules Meters 39.37 Inches
British Thermal Units 107.5 Kilogram-Meters Meters 10-3 Kilometers
British Thermal Units 2.928 x 10-4 Kilowatt-Hours Meters/Minute 1.667 Centimeters/Sec.
Centimeters of Mercury 0.01316 Atmospheres Meters/Minute 3.281 Feet/Minute
Centimeters of Mercury 0.4461 Feet of Water Meters/Minute 0.06 Kilometers/Hour
Centimeters of Mercury 136.0 Kgs./Square Meter Meters/Minute 0.03728 Miles/Hour
Centimeters of Mercury 0.1934 Pounds/Sq. Inch Miles 5280 Feet
Centimeters/Second 1.969 Feet/Minute Miles 1.6093 Kilometers
Centimeters/Second 0.6 Meters/Minute Miles 1760 Yards
Cubic Centimeters 3.531 x 10-5 Cubic Feet Miles/Hour 44.70 Centimeters/Sec.
Cubic Centimeters 6.102 x 10-2 Cubic Inches Miles/Hour 88 Feet/Minute
Cubic Centimeters 10-6 Cubic Meters Miles/Hour 1,467 Feet/Second
Cubic Centimeters 10-3 Liters Miles/Hour 1.6093 Kilometers/Hour
Cubic Feet 2.832 x 104 Cubic Cms. Miles/Hour 26.82 Meters/Minute
Cubic Feet 1728 Cubic Inches Mms. of Mercury 0.0394 Inches of Mercury
Cubic Feet 0.02832 Cubic Meters Mms. of Mercury 1.3595-3 Kgs./Square Cm.
Cubic Feet 0.03704 Cubic Yards Mms. of Mercury 0.01934 Pounds/Square Inch
Cibic Feet 7.481 Gallons Pints (Liq.) 28.87 Cubic Inches
Cubic Feet 28.32 Liters Pints (U.S. liquid) 473,179 Cubic Centimeters
Cu. Ft. of Water (60°F) 62.37 Pounds Pints (U.S. liquid) 16 Ounces (U.S. fluid)
Cubic Feet/Minute 472.0 Cubic Cms./Sec. Pounds 444,823 Dynes
Cubic Feet/Minute 0.4720 Liters/Second Pounds 453.6 Grams
Cubic Feet/Minute 62.4 Lbs. of Water/Min. Pounds 16 Ounces
Cubic Inches 16.39 Cubic Centimeters Pounds of Carbon to CO2 14,544 British Thermal Units (mean)
Cubic Inches 5.787 x 10-4 Cubic Feet Pounds of Water 27.68 Cubic Inches
Cubic Inches 1.639 x 10-5 Cubic Meters Pounds of Water 0.1198 Gallons
Cubic Inches 2.143 x 10-5 Cubic Yards Pounds of Water
Cubic Meters 106 Cubic Centimeters Evaporated at 212°F 970.3 British Thermal Units
Cubic Meters 35.31 Cubic Feet Pounds/Cubic Foot 16.02 Kgs./Cubic Meter
Cubic Meters 61,023 Cubic Inches Pounds/Square Foot 4,882 Kgs./Square Meter
Cubic Meters 1.308 Cubic Yards Pounds/Square Inch 0.06804 Atmospheres
Cubic Yards 7.646 x 105 Cubic Centimeters Pounds/Square Inch 27.7 Inches of Water
Cubic Yards 27 Cubic Feet Pounds/Square Inch 2.036 Inches of Mercury
Cubic Yards 46,656 Cubic Inches Pounds/Square Inch 703.1 Kgs./Square Meter
Cubic Yards 0.7646 Cubic Meters Pounds/Square Inch 6.895 x 103 Pascals
Feet 30.48 Centimeters Pounds/Square Inch 51.715 Millimeters of Mercury at 0°C
Feet 12 Inches Square Centimeters 1.973 x 105 Circular Mils
Feet 0.3048 Meters Square Centimeters 1.076 x 10-3 Square Feet
Feet 1/3 Yards Square Centimeters 0.1550 Square Inches
Feet of Air Square Feet 929.0 Square Centimeters
(1 atmosphere 60°F) 5.30 x 10-4 Pounds/Square Inch Square Feet 0.09290 Square Meters
Feet/Minute 0.5080 Centimeters/Sec. Square Inches 1.273 x 106 Circular Mils
Feet/Minute 0.01667 Feet/Second Square Inches 6.452 Square Centimeters
Feet/Minute 0.01829 Kilometers/Hour Square Inches 6.944 x 10-3 Square Feet
Feet/Minute 0.3048 Meters/Minute Square Inches 106 Square Mils
Feet/Minute 0.01136 Miles/Hour Square Inches 645.2 Square Millimeters
Grams/Cu. Cm. 62.43 Pounds/Cubic Foot Square Kilometers 10.76 x 106 Square Feet
Horsepower 42.44 British Thermal Units/Min. Square Kilometers 106 Square Meters
Horsepower 33,000 Foot-Pounds/Min. Square Kilometers 1.196 x 106 Square Yards
Horsepower 10.70 Kg.-Calories/Min. Square Meters 10.764 Square Feet
Horsepower 745.7 Watts Square Meters 1.196 Square Yards
Horsepower-Hours 2547 British Thermal Units Temp. (Degs. C.) + 273 1 Abs. Temp. (Degs. C.)
Inches 2.540 Centimeters Temp. (Degs. C.) + 17.8 1.8 Temp. (Degs. Fahr.)
Inches 103 Mils Temp. (Degs. F.) + 460 1 Abs. Temp. (Degs. F.)
Inches of Mercury 0.03342 Atmospheres Temp. (Degs. F.) -32 5/9 Temp. (Degs. Cent.)
Inches of Mercury 13.60 Inches of Water Watts 0.05692 British Thermal Units/Min.
Inches of Mercury 345.3 Kgs./Square Meter Watts 107 Ergs/Second
Inches of Mercury 25.40 Mms. of Mercury Watts 44.26 Foot-Pounds/Min.
Inches of Mercury 0.4912 Pounds/Square In. Watts 1.341 x 10-3 Horsepower
Inches of Water 0.002458 Atmospheres Watts 0.01434 Kg.-Calories/Min.
Inches of Water 0.07355 Inches of Mercury Watts 10-3 Kilowatts
Inches of Water 25.40 Kgs./Square Meter Watts-Hour 3.415 British Thermal Units
Inches of Water 5.204 Pounds/Square Ft. Watts-Hour 1.341 x 10- Horsepower/Hours
Inches of Water 0.03613 Pounds/Square In. Watts-Hour 10-3 Kilowatt-Hours

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I2
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Density Correction Chart

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I3
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Specific Gravity and Density of Various Gases at 60°F (1 ATM) Temperature Conversion Chart

Gas or Vapor Chemical Specific Gravity Density *In the center column, find the temperature to be converted.
Formula (lbs./cu ft.) The equivalent temperature is in the left column, if converting
Acetylene C2H2 0.899 .0686 to Celsius, and in the right column, if converting to Fahrenheit.
Air - 1.00 .0763
Ammonia NH3 0.587 .0454 °C Temp °F °C Temp °F °C Temp °F °C Temp °F
Argon A 1.377 .1053 -78.9 -110 -166 1.7 35 95.0 27.2 81 177.8 182 360 680
-73.3 -100 -148 2.2 36 96.8 27.8 82 179.6 188 370 698
Benzene C6H6 2.70 .205 -67.8 -90 -130 2.8 37 98.6 28.3 83 181.4 193 380 716
Carbon Dioxide CO2 1.539 .1166 -62.2 -80 -112 3.3 38 100.4 28.9 84 183.2 199 390 734
-56.7 -70 -94 3.9 39 102.2 29.4 85 185.0 204 400 752
Chlorine CI2 2.448 .0738 -51.1 -60 -76 4.4 40 104.0 30.0 86 186.8 210 410 770
Ethane C2H6 1.038 .0799 -45.6 -50 -58 5.0 41 105.8 30.6 87 188.6 216 420 788
Ethylene C2H4 0.969 .0739 -40.0 -40 -40 5.6 42 107.6 31.1 88 190.4 221 430 806
-34.4 -30 -22 6.1 43 109.4 31.7 89 192.2 227 440 824
Helium He 0.138 .01054 -28.9 -20 -4 6.7 44 111.2 32.2 90 194.0 232 450 842
Hydrogen H2 0.0695 .00531 -23.3 -10 14 7.2 45 113.0 32.8 91 195.8 238 460 860
-17.8 0 32 7.8 46 114.8 33.3 92 197.6 243 470 878
Hydrogen Sulfide H2S 1.19 .0897 -17.2 1 33.8 8.3 47 116.6 33.9 93 199.4 249 480 896
Methane CH4 0.555 .0424 -16.7 2 35.6 8.9 48 118.4 34.4 94 201.2 254 490 914
-16.1 3 37.4 9.4 49 120.2 35.0 95 203.0 260 500 932
Methyl Chloride CH3CI 1.785 .1356 -15.6 4 39.2 10.0 50 122.0 35.6 96 204.8 266 510 950
Nitrogen N2 0.967 .0738 -15.0 5 41.0 10.6 51 123.8 36.1 97 206.6 271 520 968
Oxygen O2 1.105 .0843 -14.4 6 42.8 11.1 52 125.6 36.7 98 208.4 277 530 986
-13.9 7 44.6 11.7 53 127.4 37.2 99 210.2 282 540 1004
Propane C3H8 1.55 .1180 -13.3 8 46.4 12.2 54 129.2 37.8 100 212.0 288 550 1022
Sulfer Oxide SO2 2.26 .1720 -12.8 9 48.2 12.8 55 131.0 43 110 230 293 560 1040
-12.2 10 50.0 13.3 56 132.8 49 120 248 299 570 1058
Water Vapor H2O 0.622 .0373 -11.7 11 51.8 13.9 57 134.6 54 130 266 304 580 1076
-11.1 12 53.6 14.4 58 136.4 60 140 284 310 590 1094
Explosive Atmosphere Classification -10.6 13 55.4 15.0 59 138.2 66 150 302 316 600 1112
-10.0 14 57.2 15.6 60 140.0 71 160 320 321 610 1130
-9.4 15 59.0 16.1 61 141.8 77 170 338 327 620 1148
North American European -8.9 16 60.8 16.7 62 143.6 82 180 356 332 630 1166
-8.3 17 62.6 17.2 63 145.4 88 190 374 338 640 1184
Class I Zone 1 -7.8 18 64.4 17.8 64 147.2 93 200 392 343 650 1202
-7.2 19 66.2 18.3 65 149.0 99 210 410 349 660 1220
Group A Group II C Acetylene -6.7 20 68.0 18.9 66 150.8 100 212 413 354 670 1238
Group B Group II C Hydrogen or equivalent hazard -6.1 21 69.8 19.4 67 152.6 104 220 428 360 680 1256
Group C Group II B Ethyle ether vapors, ethylene or -5.6 22 71.6 20.0 68 154.4 110 230 446 366 690 1274
-5.0 23 73.4 20.6 69 156.2 116 240 464 371 700 1292
cyclopropane -4.4 24 75.2 21.1 70 158.0 121 250 482 377 710 1310
Group D Group II A Gasoline, hexane, naptha, benzene, -3.9 25 77.0 21.7 71 159.8 127 260 500 382 720 1328
butane, alcohol, acetone, benzol, -3.3 26 78.8 22.2 72 161.6 132 270 518 388 730 1346
lacquer vapors or natural gas -2.8 27 80.6 22.8 73 163.4 138 280 536 393 740 1364
-2.2 28 82.4 23.3 74 165.2 143 290 554 399 750 1382
-1.7 29 84.2 23.9 75 167.0 149 300 572 404 760 1400
-1.1 30 86.0 24.4 76 168.8 154 310 590 410 770 1418
Class II -0.6 31 87.8 25.0 77 170.6 160 320 608 416 780 1436
Group E — Metal dust 0 32 89.6 25.6 78 172.4 166 330 626 421 790 1454
0.6 33 91.4 26.1 79 174.2 171 340 644 427 800 1472
Group F — Carbon black, coal or coke dust 1.1 34 93.2 26.7 80 176.0 177 350 662 432 810 1490
Group G — Flour, starch or grain
°F = 9/5C + 32 ABSOLUTE RANKIN (R) R = °F + 460
°C = 5/9 (F - 32) ABSOLUTE KELVIN (K) K = °C + 273

NEMA Classifications

NEMA Type 1 – General Purpose – Indoor Type 6 – Submersible, Watertight, Dusttight and
Type 2 – Dripproof – Indoor Sleet Resistant – Indoor and Outdoor
Type 3 – Dusttight, Raintight and Sleet (Ice) Type 7 – Class I, Group A, B, C or D Hazardous
Resistant – Outdoor Locations; Air Break Equipment – Indoor
3R – Rainproof and Sleet (Ice) Resistant Type 8 – Class I, Group A, B, C or D Hazardous
– Outdoor Locations; Oil-immersed Equipment – Indoor
3S – Dusttight, Raintight and Sleet (Ice) Type 9 – Class II, Group E, F or G Hazardous
Proof – Outdoor Locations; Air-break Equipment – Indoor
Type 4 – W atertight and Dusttight – Indoor Type 10 – Bureau of Mines
4X – W atertight, Dusttight and Corrosion Type 11 – Corrosion Resistant and Dripproof;
Resistant – Outdoor Oil-immersed – Indoor
Type 5 – Superseded by Type 12 for Control Type 12 – Industrial Use, Dusttight and Driptight
Apparatus – Indoor
Type 13 – Oiltight and Dusttight – Indoor
Ref: NEMA Standards Publication, Pub. No. 1CS–1970

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I4
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Physical Laws for Blower Applications

In the following formulae these symbols are used: “Standard Air” – Air at 68°F (absolute temperature 528°) and
29.92” Hg. (barometric pressure at sea level). The density of
P – Pressure in pounds per square inch (PSI) or inches of such air is 0.075 lbs./cu. ft. and the specific volume is 13.29 cu.
mercury column (inches Hg) ft./lb. The specific gravity is 1.0.
CFM – Volume in cubic feet per minute
RPM – Speed in revolutions per minute The outlet pressure of a blower depends on the condition of
D – Density in pounds per cubic foot (lbs./cu. ft.) the air or gas at the inlet. The inlet condition is influenced by:
H – Height of air or gas column (ft.) a – Specific gravity (The ratio of density of the gas to density of
SG – Specific Gravity (ratio of density of gas to the density standard air)
of air) b – Altitude (location of blower)
c – Temperature of inlet air
Basic Fan Laws Chart

VA R I A B L E V O L U ME P R E S S UR E H O R S E P OW E R
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio Varies with CUBE of Speed Ratio
CFM 2 = CFM 1
RPM 2
RPM 1
( ) P2 = P 1
RPM 2 2
RPM 1
( ) HP 2 = HP 1 (
RPM 2 3
RPM 1
)
WHEN DENSITY CHANGES Does Not Change Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
P2 = P 1 D2
D1
( ) HP 2 = HP 1 D2
D1
( )
Volume

The Volume changes in direct ratio to the speed. V 1 = Original Volume (1000 CFM)
Example – A blower is operating at 3500 RPM and delivering V 2 = New Volume
1000 cfm. If the speed is reduced to 3000 RPM, what is the new RPM 1 = Original Speed (3500 RPM)
RPM 2 = New Speed (3000 RPM)
volume?
V2 = V 1 ( RPM
RPM
) 2
1
1
= 1000 x ( 3500
3000
) 1
= 1000 x .857 = 857 CFM

Pressure

Pressure (barometric) varies in direct proportion to Let: V 1 = Volume of standard air (1000 CFM)
altitude. V 2 = Volume of thinner air
Example – A blower is to operate at an elevation of 6000 feet Hg 1 = Barometric pressure sea level (29.92)
and is to deliver 3 PSI pressure. What pressure (standard air) Hg 2 = Barometric pressure 6000’ (23.98)
blower is required?
Hg 1 29.92
29.92 V2 = V 1 x = 1000 x = 1248 CFM
Pressure = 3 x = 3.75 or 3 3/4 lb. Hg 2 23.98
23.98
If it is desired to determine what pressure a 3 lb. (standard air) The pressure changes as the square of the speed ratio.
blower will deliver at 6000 feet –
Example – A blower is operating at a speed of 3500 RPM and
23.98 delivering air at 5.0 pounds pressure. If the speed is reduced to
Pressure = 3 x = 2.4 or about 2 1/2 lb. 3000 RPM, what is the new pressure?
29.92
When a blower is to operate at a high altitude it is frequently P 1 = Original Pressure (5 lbs.)
specified that the blower be capable of handling a given vol- P 2 = New Pressure
ume of “standard air”. It is then necessary to determine the RPM 1 = Original Speed (3500 RPM)
equivalent volume of air at the higher altitude. RPM 2 = New Speed (3000 RPM)
Example – A blower is to operate 6000 feet altitude and is to
handle 1000 CFM of standard air. What is the CFM of air the
blower must handle at 6000 feet altitude?
P2 = P 1 ( RPM
RPM
) 1
2
2
= 5x ( 3500
3000
) 2
= 5 x .735 = 3.68 pounds

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I5
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Pressure (Cont’d)

The Air Density varies in inverse proportion to the Pressure varies in direct proportion to the density.
absolute temperature. Example – A 3 lb. (standard air) blower is to be used to handle
Example – A blower is to handle 200°F air at 3 PSI pressure. gas having a specific gravity of 0.5. What pressure does the
What pressure (standard air) blower is required? blower create when handling the gas?
Let: P 1 = Pressure hot air (3 PSI) Let: Pa = Air pressure (3 lb.)
P 2 = Pressure standard air Pg = Gas pressure
AT 1 = Absolute temperature hot air (200+460=660°F) SG = Specific gravity of gas (0.5)
AT 2 = Absolute temperature standard air (68+460=528°F)
Pg = Pa x SG = 3 x .5 = 1.5 lb.
AT 1
P2 = P 1 x = 3 x 660 = 3.75 or 3 3/4 lb.
AT 2 528
If we are required to handle a gas having a specific gravity of 0.5
at 1.5 lb. pressure, we can determine the standard air pressure
A blower is capable of delivering 3 PSI pressure with standard blower as follows:
air. What pressure will it develop handling 200°F inlet air?
AT 2 Pg 1.5
P1 = P 2 x = 3 x 528 = 2.4 or about 2 1/2 lb. Let: Pa = = = 3 lb.
AT 1 660 SG .5

The following table gives the barometric pressure of various altitudes:


Absolute Pressure At Altitudes Above Sea Level (Based on U.S. Standard Atmosphere)
Altitude Pressure Altitude Pressure Altitude Pressure
Feet In. Hg. PSIA Feet In. Hg. PSIA Feet In. Hg. PSIA
0 29.92 14.70 2,500 27.31 13.41 7,000 23.09 11.34
500 29.38 14.43 3,000 26.81 13.19 7,500 22.65 11.12
600 29.28 14.38 3,500 26.32 12.92 8,000 22.22 10.90
700 29.18 14.33 4,000 25.84 12.70 8,500 21.80 10.70
800 29.07 14.28 4,500 25.36 12.45 9,000 21.38 10.50
900 28.97 14.23 5,000 24.89 12.23 9,500 20.98 10.90
1,000 28.86 14.18 5,500 24.43 12.00 10,000 20.58 10.10
1,500 28.33 13.90 6,000 23.98 11.77
2,000 27.82 13.67 6,500 23.53 11.56

Horsepower

The horsepower changes as the cube of the speed Horsepower vs. Specific Gravity & Ratio of density.
ratio. The horsepower varies in direct proportion to the specific gravity
Example – A blower is operating at a speed of 3500 RPM and (ratio of density of gas to density of air).
requiring 50 horsepower. If the speed is reduced to 3000 RPM, Example – A standard air blower requires a 10 HP motor. What
what is the new required horsepower? horsepower is required when this blower is to handle a gas
whose specific gravity is 0.5?
HP 1 = Original Horsepower (50)
HP 2 = New Horsepower HP = 10 x 0.5 = 5 horsepower
RPM 1 = Original Speed (3500 RPM)

RPM 2 = New Speed (3000 RPM) It is possible that several of the above modifications may be
required on one installation. Therefore, it may be necessary to
HP 2 = HP 1 x ( RPM
RPM
) = 50 x ( 3500
2
1
3
) 3
3000 = 50 x .630 = 31.5 horsepower use various combinations of these formulae.

The above is known as the 1-2-3 rule of blowers.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I6
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Orifice Flow

Orifice Flow Calculation ORIFICE PRESSURE DROP AS A FUNCTION


OF FLOW AND ORIFICE AREA (C=.65)
To determine air flow through an orifice:

( )
V 2 100
V = CK √ P Q = AV VP =
K
Where:
80
V = V elocity in feet per minute (fpm)
C = Orifice Coefficient
K = Constant = 14,786 when P is expressed

Inches of Water
Pressure Drop
60
in In. Hg
21,094 when P is expressed
in PSIG
4,005 when P is expressed 40
in In. of Water
(Above constants are based on an air density
of 0.075 lbs/ft 3) 20
P = Pressure differential across the orifice
Q = Flow rate in cubic feet per minute (CFM)
A = T otal orifice area expressed in square feet 0 100 200 300 400 500
VP = Velocity pressure (units are those of pressure)
Flow Rate SCFM
200
Coefficient C for Orifices Under
Vacuum or Pressure Flow 180

160

140
Inches of Water
Pressure Drop

120

100
c-.98 c-.92 c-.82 c-.80 80

60

40

20

500 700 900 1100 1300 1500


c-.72 c-.65 c-.80 c-.53 Flow Rate SCFM
150

135
Area of Orifices
Orifice Diameter in Inches 120

Diameter 105
Inches of Water
Pressure Drop

in Inches Square Inches Square Feet 90


1/8 .01227 .000085
75
3/16 .02761 .00019
1/4 .04908 .00034 60
3/8 .11044 .00076
45
1/2 .19634 .00136
5/8 .30679 .00213 30
7/8 .60132 .00417
15
1.0 .78539 .00545
Orifice area (in sq. inches) = .25 X π X (orifice diameter in inches) 2 1500 1700 1900 2100 2300 2500
Orifice area (in sq. feet) = Area in sq. inches ÷ 144 Flow Rate SCFM

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I7
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Friction Loss Per Foot of Tubing

Friction Loss in Fittings

To calculate friction loss in fittings use chart below. This chart will yield equivalent
lengths (in feet) of tubing. Use this length with graph above to find friction loss in
inches of water column.

NOMINAL PIPE SIZE (INCHES) EQUIVALENT TUBING LENGTH (FEET)


90° EL 45° EL
1 1/4 3 1.5
1 1/2 4 2
2 5 2.5
2 1/2 6 3
3 7 4
4 10 5
5 12 6
6 15 7.5
8 20 10

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I8
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Noise Facts

• OSHA (Occupational Safety & Health Administration) regulates and monitors in-plant noise.
• Allowable noise is a function of dBA level at certain distance over an exposure time.
• OSHA regulations state 90 dBA for an 8 hour work period using slow responic setting on meter.
• Adding a second noise producer of equal dBA will add 3 dBA to the first dBA reading.
• Sound pressure level (SPL) decreases with distance (d)
(SPL) 2 = (SPL) 1 - 20LOG ( d1
d2
)
Therefore, each doubling of distance results in 6 dBA reduction.

Loudness Levels of Familiar Noises (Approximate Average Including Ear Nework)

1013 130 Threshold of Painful Feeling


Airplane and Propeller at 10

10 12
120 Ft.
watts per sq. cm.)

DEAFENING 1011 110 Train Passing at High Speed


L E V E L S

1010 100 Riveter at 30 Ft. Auto Horn at 20 Ft.


Pneumatic Drill at 10 Ft.
Subway Train
Fire Siren at 75 Ft. Noisy Street
109 90 Railway
16

Noisy Street
Police Whistle at 15 Ft. Auto at 60
N O I S E

MPH
NOISY
Relative Intensities (Intensity Above Threshold = 10

Loudness Levels in Decibels

108 80
Very Noisy Restaurant. Auto at 40
MPH Average Stenographic Room

107 70 Factories. Auto at 20 MPH


Noise in Pullman (Windows Shut)
Noisy Office
Average Restaurant
A P P R O X I M A T E

AVERAGE 106 60 Dept. Store. Average Conversation at


3 Ft.
Average Office. Quiet
Street Noisy Residence
105 50 Quiet Restaurant Quiet
Office
QUIET Museum
104 40 Average School
Average Residence
Motion Picture Theater
Library Reading
VERY QUIET 103 30 Rooms Auditoriums
Average Whisper at 5
Ft. Very Quiet
Residence
102 20
Broadcasting Studio
Zero of A.I.E.E. Scale 14
SOUND PROOF
R OOMS 10 10 Db.
Zero of Original Scale 8.5

1 1 Db. Threshold of Audibility

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763
1258 Customer Service Fax: +1 215.256.1338
I9
www.ametekdfs.com ____
Application Engineering Basics

Industrial Blower Noise Chart* in dBA

Mode Mode Mode Mode Mode


Model Model Model Model Model
Suction Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure
SE 60-62 60-62 101 65-67 66-68 513 80-81 80-81 757 83-85 84-86 S/P 9 90-91 90-91
MF 64-65 64-65 202 67-69 68-70 505 77-78 76-77 808 84-85 84-85 909 81-82 84-86
RDC 76-78 76-78 303 65-67 67-69 523 82-83 82-83 633 81-82 81-82 1233 84-85 84-85
SL2 69-72 69-72 353 72-73 73-74 555 80-81 80-81 S7 88-89 88-89 S/P 13 87-88 90-91
SL4 72-78 72-78 404 73-74 74-75 656 82-83 82-83 858 84-85 84-85 14 86-87 86-87
SL5 76-79 76-79 454 76-77 75-76 6 85-86 85-86 833 82-84 82-84 S/P 15 91-92 91-92

* Average at 1 meter, 4 places around the blower

dBA at Distance Conversion Chart

To read, use straight


edge to connect blower
distance and dBA rating.
A pivot point A will be
developed. Use straight
edge again with new
distance and pivot point A
to read dBA at new
distance.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477

USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763

1258 Customer Service Fax: +1 215.256.1338


I 10

www.ametekdfs.com ____
Application Engineering Basics

Standard Regenerative Blower Nomenclature Reference

This chart explains the nomenclature behind the catalogued blower model names. This tool can be used to explain
to customers what the letters and numbers mean, and will also allow you to become familiar with our model names.
This information should not affect the way orders are placed; please continue to use the model names shown in
the catalog and price pages. Any special request should be noted on the order.

Special Features, 0 to 4 letters


- see figure 2
Voltage Code, up to 3 numbers - see figure 1
Motor Description - see figure 3
(TEFC, XP, Chem, and ODP)
Describes which family the unit belongs to, 1 to 3 numbers
Option, for duplex units only
P = Parallel configuration
S = Series configuration
Figure 2 Special Features
DR = Domestic Regenerative
EN = Environmental A SPECIAL (not covered by any other letter)
CP = Chemical Process
B
HiE = Hi Efficiency Motor
C Blower on pressure only
D Blower on suction only
E
F
Figure 1 Voltage Code
G
H V apor recovery service - hydrocarbon
5 230 VAC 60 Hz, Single Phase J Nasty Gas face seal
9 115/230 VAC 50/60 Hz, Single Phase K
33 230 VAC 60 Hz, Three Phase L Lo leak option (lip seal)
58 115/230 VAC 60 Hz Single Phase M Die Cast or muffler extension
60 200 VAC 50/60 Hz Single Phase P
72 230/460 VAC 60 Hz Three Phase Q
75 380 VAC 50 Hz Three Phase R Chem-Tough™ construction
86 575 VAC 60 Hz Three Phase S Special manifold
T
89 200-230/460 VAC 60 Hz, Three Phase
U
91 230/460 VAC 50/60 Hz, Three Phase
V V alve
92 415 VAC 50 Hz, Three Phase
W Rail mounted blower
201 380 VAC 60 Hz X Base mounted blower
Y Slip on flange
Z Package blower coupling drive
AA Package blower belt drive, simplex
BB Package blower drive belt, duplex
RD Remote drive
NT No Tower

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I 11
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Standard Regenerative Blower Nomenclature Reference (Cont’d)

Figure 3 Motor Description

HP Motor Thermal HP Motor Thermal


Type Protection Type Protection

D 5.0 TEFC No CJ 2.5 XP Yes


E 5.0 ODP No CK 4.0 TEFC No
F 5.0 XP Yes CR 4.0 CHEM TEFC No
K 3.0 TEFC No CS 3.0 CHEMTEFC No
M 3.0 XP Yes CT 2.0 CHEM TEFC No
R 1.5 TEFC No CU 1.0 CHEM TEFC No
V 1.5 ODP Yes DC 1/8 TEFC Yes
W 1.5 XP Yes DJ 1/16 TEFC Yes
X 7.5 ODP No DW 30 TEFC No
Y 1/3 TEFC No DX 30 XP Yes
AD 1/3 XP Yes EE 60 ODP No
AE 1/2 TEFC No EZ 1.5 CHEM TEFC No
AG 1/2 XP No FA 1/2 CHEM TEFC No
AK 1/2 XP Yes FB 1/4 CHEM TEFC No
AL 1.0 TEFC No FD 3/4 CHEM TEFC No
AR 1.0 XP Yes FE 2.5 CHEM TEFC No
AS 2.0 TEFC No FF 5 CHEM TEFC No
AW 2.0 ODP Yes FG 7.5 CHEM TEFC No
AX 2.0 XP Yes FH 10 CHEM TEFC No
AY 7.5 TEFC No FJ 15 CHEM TEFC No
BA 7.5 XP Yes FK 30 CHEM TEFC No
BB 10 TEFC No FL 5.5 XP Yes
BC 10 ODP No FM 1/4 CHEM XP No
BD 10 XP Yes FN 1/2 CHEM XP No
BE 15 TEFC No FQ 1.0 CHEM XP Yes
BG 15 XP Yes FR 1.5 CHEM XP Yes
BH 20 TEFC No FS 2.0 CHEM XP Yes
BK 20 XP Yes FU 3.0 CHEM XP Yes
BL 15 ODP No FW 5.0 CHEM XP Yes
BM 20 ODP No FX 5.5 CHEM XP Yes
BP 30 ODP No FY 7.5 CHEM XP Yes
BQ 40 ODP No FZ 10 CHEM XP Yes
BR 3/4 TEFC No GA 15 CHEM XP Yes
BX 1/4 TEFC No GB 20 CHEM XP Yes
CB 1/4 ODP Yes GC 30 CHEM XP Yes
CC 1/4 XP Yes GD 20 CHEM TEFC No
CD 2.5 TEFC No GE 11.5 TEFC No
RD Remote Drive - No Motor

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I 12
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
Application Engineering Basics

Corrosion-Resistant and Sanitary Blowers Application Data Sheet

To obtain Application Engineering assistance or a quotation for your specific need, please photocopy this
form, fill out as much as possible, and fax it back to Rotron. We look forward to working with you.

GAS CONCENTRATION / DESCRIPTION


Percentage Gas Specific Gravity
COMPANY
________ % _______________ (SG =
CONTACT
_______ ) ________ % _______________
ADDRESS (SG
________ % = _______ )
_______________ (SG =
ADDRESS
_______ ) ________ % _______________
C IT Y S TAT E ZIP (SG = _______ )
______
% 100
_______________
__ (SG = _______ )
P HONE FAX

GAS Corrosive Yes No Explosive Yes No


CLASSIFICATION: Corrosive Yes No Explosive Yes No
AREA
CLASSIFICATION:REQUEST: Fill in and circle choice
PERFORMANCE

SCFM ° (F / C)
FLOW INLET TEMPERATURE

PSI (A / G) ° (F / C)
INLET PRESSURE AREA AMBIENT TEMPERATURE

PSI (A / G) (Ft / M)
OUTLET PRESSURE SITE ALTITUDE

APPLICATION DESCRIPTION: Attach sketch if necessary

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763
1258 Customer Service Fax: +1 215.256.1338
I 13
www.ametekdfs.com ____
Application Engineering Basics

Warranty Statement

Warranty Statements Hazardous Locations Policy

1. AMETEK ROTRON DR, EN, and HiE regenerative direct drive AMETEK ROTRON will not knowingly specify, design or build any
blowers are guaranteed for one full year from the date of regenerative blower for installation in a hazardous, explosive
installation (limited to 18 months from the date of shipment.) to location without proper NEMA motor enclosure. AMETEK
the original purchaser only. Should blower fail, we will evaluate ROTRON does not recognize sealed blowers as a substitue for
the failure. If failure is determined to be workmanship or explosion-proof motors. Sealed units with standard TEFC
material defect related, motors should never be utilized where local, state, and/or
federal codes specify the use of explosion-proof equipment.
2. Standard Products - AMETEK ROTRON moisture separators,
remote drives, packaged units, CP blowers, Nasty GasTM models AMETEK ROTRON has a complete line of regenerative blowers
and special built (EO) products are guaranteed for one full year with explosion-proof motors, Division 1 & 2, Class I, Group D;
from the date of shipment for workmanship and material defect Class II, Groups F & G requirements are met with these standard
to the original purchaser only. Should the blower fail, we will explosion-proof blowers.
evaluate the failure. If failure is determined to be workmanship
or material defect related, we will at our option repair or replace AMETEK ROTRON will not knowingly specify, design or build any
the blower. regenerative blower for installation in a hazardous, corrosive
environment without the proper surface treatment and sealing
3. Parts Policy - AMETEK ROTRON spare parts and accessories options.
are guaranteed for three months from the date of shipment for
workmanship and material defect to the original purchaser only. AMETEK ROTRON has a complete line of Chemical Processing
If failure is determined to be workmanship or material defect and Nasty GasTM regenerative blowers with Chem-ToughTM,
related we will at our option repair or replace the part. stainless steel parts, and seals.

4. Non-Standard Products - Orders for specially-built products AMETEK ROTRON offers general application guidance, however,
will be concidered as non-cancellable. Any requested changed suitability of the particular blower selection is ultimately the
by customer after order acceptance will result in additional responsibility of the purchaser, not the manufacturer of the
charges. blower.

Corrective Action - A written report will be provided indicating


reason(s) for failure, with suggestions for corrective action.
Subsequent customer failures due to abuse, misuse, misapplica-
tion or repeat offense will not be covered. AMETEK ROTRON will
then notify you or your options. Any failed unit that is tampered
with by attempting repair or diagnosis will void the warranty
unless authorized by the factory.

Terms and Conditions - Our warranty covers repairs or replace-


ment or regenerative blowers only, and will not cover labor for
installation, outbound and inbound shipping costs, accessories
or other items not considered integral blower parts. Charges
may be incurred on products returned for reasons other than
failures covered by their appropriate warranty. Out-of-warranty
product and in warranty product returned for failures deter-
mined to be caused by abuse, misuse, or repeat offense will be
subject to an evaluation charge. Maximum liability will in no
case exceed the value of the product purchased. Damage
resulting from mishandling during shipping is not covered by
this warranty. It is the responsibility of the purchaser to file
claims with the carrier. Other terms and conditions of sale are
stated on the back of the order acknowledgement.

This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled
laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual performance will vary depending on the operating environment and application.
AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product
designed to meet specific applications, contact AMETEK Technical & Industrial Products Sales department.
AMETEK DYNAMIC FLUID SOLUTIONS
75 North Street, Saugerties, NY 12477
USA: +1 215-256-6601 - Europe: +49 7703 930909 - Asia: +86 21 5763 1258 I 14
Customer Service Fax: +1 215.256.1338
www.ametekdfs.com ____
AMETEK, Inc.
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with
annualized sales of more than $2.5 billion. AMETEK has nearly 11,000 colleagues working at more than 80
manufacturing facilities and more than 60 sales and service centers in the United States and over 30 other
countries around the world.

AMETEK DYNAMIC FLUID SOLUTIONS (DFS)


AMETEK Technical & Industrial Products is a world leader in motors, blowers and pumps for mass-transit,
medical, business machine and computer applications. It also is a leader in regenerative blowers for pressure and
vacuum applications used by broad range of industries.

AMETEK supports its customers globally from its manufacturing facilities in Minnesota, New York, North
Carolina, Ohio, Pennsylvania, Italy and China. Our brushless DC motors, blowers, controllers, pumps, and fans are
ideally suited for a wide range of applications, including medical instruments, robotics, pumps, compressors, offi ce
equipment, fans, machine tools, tape drives, or any other precise rotary motion/air delivery applications.

Technical & Industrial Products’ product line of regenerative blowers for pressure and vacuum applications
services the process, industrial, environmental, waste, and wastewater industrial industry. Typical applications
areas include solution agitation and aeration, pneumatic conveying, part hold-down and pick up, part blow off, gas
and fume extraction, and process gas handling.

AMETEK Technical & Industrial Products supplies the solution for unique performance, mounting,
environmental and agency requirements.

DYNAMIC FLUID SOLUTIONS

100 East Erie St. Kent OH USA 44240


USA: +1 330-677-3327 - Europe: +49 7703 930909 - Asia: +86 21
5763 1258 Customer Service Fax: +1 215.256.1338
www.ametekdfs.com

Вам также может понравиться