Вы находитесь на странице: 1из 7

Page 1

Job No Sheet No Dwg Ref Rev No

Job Title
Part of Structure
Client Prepared Date
Chk By 09-29-2017

1.0 Synopsis

Two proposed steel canopies to be built at 2/F and 1/F of Commerical Building at
Wing Hong Street and Yu Chau West Street, Cheung Sha Wan, Kowloon, N.K.I.L.6572.

i. 2190mm Canopy at 2F Grid 1/C-E


Canopy overall size to be 2190mm x 10990mm x 800mmH where located at 2/F Grid 1/C~E.

Structural System for Canopy


The structural system for this proposed canopy to be in form of structural steel. The load path is started from
SB6 (simply supported) > SB5 > HP2 > SB7 (simply supported) > SB8/SB9 (simply supported)
> CSB2 > parent structure.
All based supports at 2/F level +17.80mPD are restrainted fixed end.
The loading schedule for all unfactored load cases to be shown in this report.

Analysis and Design Approach


The analysis and design approach for this canopy is utilized of Linear Analysis
and Design by utilized of Pre-accepted Structural Programe NIDA Professional v10.0 (BD Ref: S1015).
The full set of input, and output data with design output will be attached in this report.

Other Consideration (Deflection)


By referring to deflection output from NIDA Professional which attached in this report.
≤ Allowable Deflection Limit
Vertical Deflection, δ = 8.301 12.167 mm
Vertical Deflection, δ = 17.374 20.300 mm
Vertical Deflection, δ = 10.497 11.500 mm
Therefore, it is structurally safe in serviceability aspect.

2.0 List of Reference

a. Building (Construction) Regulations, 2012.


b. The code of practice for Dead and Imposed Loads, 2011.
c. The code of practice on wind effects in Hong Kong, 2004.
d. The code of practice for the Structural Use of Steel, 2011.
e. BS-8118 Structural Use of Aluminum, Code of Practice for Design.
f. SCI P-291 Structural Design of Stainless Steel.
Page 2
Job No Sheet No Dwg Ref Rev No

Job Title
Part of Structure
Client Prepared Date
Chk By 09-29-2017

3.0 Material Specification

a. Structural Steel
i. All structural steel other than hollow section to be S275 class 1 to BS EN 10025 PART 2, 2004
ii. All structural hollow section to be S275 class 1 to BS EN 10210 PART 1, 1994
iii. The steel strengths = 275 MPa.

b. Welds
i. All welds to BS EN 1011 PART 1:1998 & PART 2:2001.
ii. The design strength of fillet welds stress = 220 MPa

c. Concrete
i. Design concrete grade for structural member to be Grade C45 with characteristic strength 45MPa.

d. Aluminum notes
i. All aluminum to be complied with BS 8118-Part 1:1991.
ii. Design stress for thickness up to 25mm
Density = 27.0kN/m³
Modulus of Elasticity = 70000MPa.
Modulus of Rigidity, G = 26600MPa.
Coefficient of Thermal Expansion = 23.0x10-6 /°C
iii. Limiting Stresses for heat-treatable alloys.
Aluminium Panel = 3003-H14
Limitng Stress for Bending and Overall Yielding, po = 125 MPa
iv. Deflection Limit = L/120

e. Bolts
ii. All Stainless Steel Bolts to be Grade Class-70, unless otherwise stated and comply with BS EN ISO 3506-1&2:1998
iii. Grade = Class 70
Shear Strength, ps = 311 MPa
Bearing Strength, pbb = 828 MPa
Tensile Strength, pt = 450 MPa
Page 3

2190mm Canopy – Loading Schedule


Version 10.0

2020-12-16 12:
Project: SECTIONS:
1 CSB2 D200x50x10x10
2 SB5 SHS50x5.0
Boundary Conditions:
3 SB6 RHS100x50x6.3~
i. all supports to be fixed end. 12 4 SB7 RHS100x50x5.0~
ii. members with "dotted" to be pinned end. 5 SB8 SD120x16
6 SB9 RHS100x50x5.0~
iii. all members except "dotted" to be inter-connect with rigid connections. 7 HP2 D100x50x12x12

10

15
Page 4

Z
Y X

Unit: N, mm

File: canopy 2190 r1 20201210 12:27, December 16, 2020


Loading Schedule for Canopy at 2/F
DL LL Wz Wx Wy
Node Fx Fy Fz Mx Mz Fx Fy Fz Mx Mz Fx Fy Fz Mx Mz Fx Fy Fz Mx Mz Fx Fy Fz Mx Mz
4 0.514 -0.464 -5.670 -7.526 0.091 0.295 -0.303 -3.661 -4.503 0.055 0.743 -0.655 -7.320 -10.897 0.134 21.175 0.422 0.669 0.258 -3.788 4.849 8.318 0.001 1.913 -0.300
6 -0.068 0.000 -5.408 -6.533 0.009 -0.048 0.000 -3.641 -4.143 0.007 -0.103 0.000 -6.878 -9.737 0.013 13.271 0.000 -0.023 -0.051 -2.451 0.245 8.832 0.010 1.445 -0.008
8 -0.040 0.000 -5.387 -6.419 0.005 -0.025 0.000 -3.621 -4.042 0.004 -0.068 0.000 -6.844 -9.564 0.009 11.649 0.000 -0.050 -0.158 -2.274 0.200 8.832 0.004 1.416 -0.008
10 0.199 -0.745 -4.116 -5.256 0.075 0.073 -0.497 -2.216 -2.434 0.034 0.291 -1.046 -5.153 -7.498 0.111 9.580 75.345 -4.260 -3.052 -2.084 1.930 3.634 0.015 1.307 -0.185
12 -0.599 0.745 -0.930 -0.281 0.013 -0.330 0.497 0.030 -0.096 0.002 -0.840 1.046 -1.221 -0.404 0.018 55.151 -75.345 4.785 3.517 -1.899 -5.046 9.637 -0.020 0.643 -0.756
15 -0.005 0.464 -2.425 -1.991 -0.148 0.034 0.303 -1.138 -1.051 -0.098 -0.023 0.655 -3.047 -2.759 -0.209 -2.742 -0.422 -1.120 -0.810 -0.405 -2.179 8.239 -0.010 0.149 -2.248
Σ= 0.000 0.000 -23.935 -28.004 0.046 0.000 0.000 -14.247 -16.270 0.004 0.000 0.000 -30.463 -40.860 0.076 108.084 0.000 0.000 -0.297 -12.900 0.000 47.492 0.000 6.873 -3.505
Page 5
Page 6

2190mm Canopy – Connection and Support Design


Version 10.0

2020-12-16 12:
Project: SECTIONS:
1 CSB2 D200x50x10x10
2 SB5 SHS50x5.0
member design nodes - max capacity factor 3 SB6 RHS100x50x6.3~
(252) (275)
(276) 4 SB7 RHS100x50x5.0~
(134) 5 SB8 SD120x16
6 SB9 RHS100x50x5.0~
7 HP2 D100x50x12x12

(193)

(267)

(106)
Page 7

Z
Y X

Unit: kN, m

File: canopy 2190 r1 20201210 12:01, December 16, 2020