Sometimes during a deployment you might not be able to or want to install ESXi to the embedded SD Card controller on the Dell
PowerEdge servers, for example if your memory con guration exceeds 512GB of RAM then installing ESXi to an SD Card would not be
supported, or you may want to have a locally de ned Scratch Partition on a local VMFS volume rather than using a remote Syslog or NFS
Share, so what are the options?

Well you could boot ESXi from a single disk, the downside to that is if the disk fails then you are in a host down situation, the other option is
to use two disks in a RAID1 mirror and use that for the ESXi installation.? With servers such as the R730XD you can utilise all 24 drive slots
in the front of the server for Virtual SAN, and then two rear 2.5 Inch slots for your RAID 1 Mirror drives.? In my lab environment I have a
similar con g, I have a bunch of SSD drives used by Virtual SAN and then two 300GB 10K SAS Drives in a RAID 1 Mirror for my ESXi install
and local VMFS Volume.? So how do we con gure the H730 controller to support both Passthrough Disks and RAID disks?

Please note: For production environments this type of con guration is not supported

The rst thing we need to do is ensure that the controller itself is con gured for RAID Mode, for those that do not know, the H730
controller can be con gured in either RAID Mode or HBA Mode.? RAID Mode allows you to create RAID Virtual Disks to be handled by the
Logical Disk Controller as part of a RAID Volume, it also allows you to con gure physical disks as NON-RAID disks, HBA Mode allows you
to con gure disks as NON-RAID capable only, in order to set the controller as RAID Mode we need to enter the System Setup Screen, to do
this reboot the host and press F2 to enter the System Setup Main Menu, once there we need to enter the Device Settings option

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 1/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

This section of the System Setup will allow you to change the settings for any devices connected in the system, for the purpose of this
article we will be focusing on the PERC H730 controller, in my servers I have two controllers, so I am selecting the one that is second in the
list labelled RAID Controller in Slot 3: Dell PERC <PERC H730P Adapter> Con guration Utility

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 2/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

Once in the Device settings we need to chose the option for Controller Management and at the way to the bottom and choose the option
for Advanced Controller Management, in there you will see an option for Switch to RAID Mode, when selected it will inform you that a
reboot is required, do not reboot the host just yet.

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 3/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

Now we need to ensure that NON-RAID Disk Mode is enabled, for this, click on Back and enter the Advanced Controller Properties at the
bottom of the screen and select the option to enable for Non RAID Disk Mode and hit Apply Changed

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 4/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

At this point you will need to make the disks you wish to use as a RAID1 as RAID Capable, you can do this under Con guration
Management and choose the option to Convert to RAID Capable, from within here select the two disks you wish to use as your RAID 1
and click on OK, check the Con rm box and click on yes to con rm

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 5/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

Click on Back to go to the main menu and then re-select Con guration Management and chose the option to Create Virtual Disk and
proceed to create your RAID 1 disk, it will only let you select disks that have been switched to RAID capable, after completion, check that
all other disks are seen as NON-RAID Disks under Physical Disk Management, since we switched the controller from HBA Mode to RAID
Mode all the other disks should still be tagged as NON-RAID

Now your PERC H730 controller is con gured for both RAID and Passthrough and your RAID1 Virtual Disk can be used to install your
ESXi, during the ESXi installation, make sure you install to the correct disk, and all your other disks are passthrough mode and can be
consumed by Virtual SAN

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 6/7
5/30/2019 Configuring the Dell PERC H730 Controller for Passthrough and RAID - MrVSAN

2 THOUGHTS ON “CONFIGURING THE DELL PERC H730 CONTROLLER FOR PASSTHROUGH AND RAID”

mario
MARCH 28, 2017 AT 8:17 PM

This is against VMware best practices https://kb.vmware.com/selfservice/microsites/search.do?


language=en_US&cmd=displayKC&externalId=2136374

 MrVSAN
JULY 15, 2017 AT 8:32 PM

Thanks Mario

As the article states, for Production Environments this is not supported

This site uses Akismet to reduce spam. Learn how your comment data is processed.

www.mrvsan.com/configuring-the-dell-perc-h730-controller-for-passthrough-and-raid/ 7/7

Вам также может понравиться