EMC Test Report

Equipment Under Test : AN5161-CGF


Testing Time:2020.7.30-2020.8.01
Testing Company:FiberHome Telecommunication Technologies Co.,Ltd---- EMC Lab
Testing Number:20300
EMC Test Engineer:Zhang mingquan Approved by:Li huifen

目录
1. Description of Equipment..............................................................................................................1
2. Standard......................................................................................................................................... 3
3. Test Item and Test Result...............................................................................................................3
4. Evaluation of test results................................................................................................................4
5. Test Data and Results.....................................................................................................................5
5.1 Conducted Disturbance............................................................................................................ 5
5.2 Radiation Disturbance Measurement....................................................................................... 9
5.3 Voltage Fluctuations and Flicker............................................................................................ 13
5.4 Electrostatic Discharge Immunity Test.................................................................................. 14
5.5 Radiated Electric Fields Immunity Test................................................................................. 15
5.6 Electrical Fast Transient Bursts Immunity Test..................................................................... 16
5.7 Surges Immunity Test............................................................................................................. 16
5.8 Immunity To Continuous Conducted Disturbances............................................................ 17
5.9 Power frequency magnetic field immunity test..................................................................... 18
5.10 Voltage Dips Immunity Test.................................................................................................... 19
1. Description of Equipment

Name of EUT: AN5161-CGF


Input:
Power Supply (1)AC port:220VAC;
(2)DC Port:-48VDC;
Optical Port: GPON*2;GE5,GE6 (Ethernet PON)
Signal Port Signal Port:GE*4
Other:GE*n,CONFIG,CONSOLE,ALARM IN,CLK/TOD
Manufacturer FiberHome Telecommunication Technologies Co.,Ltd

1.1 Equipment pictures And Test Setup Block Diagram

EUT Photos
220VAC Ethernet Cable
EUT GE*4

or
-48VDC
GPON GE5 GE6 SmartBits
600B
Optical Fiber or Optical Fiber

Ethernet Cable
OLT

Test Setup Block Diagram

2. Standard

ETSI EN 300 386 V 2.1.1 (2016-07)


FCC PART 15:2016
EN 55024:2010
EN 55032:2015 + AC:2016
EN 55035:2017
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-4-2:2009
EN 61000-4-3:2006 + A1:2008 + A2:2010
EN 61000-4-4:2004+ A1:2010
EN 61000-4-5:2006
EN 61000-4-6:2009
EN 61000-4-8:2010
EN 61000-4-11:2004
ITU-T k.21:2003
ITU-T k.44:2003
3. Test Item and Test Result

No. Item Requirement of Standard Test Result


The Mains and Signal lines Port :
1 Conducted disturbance measurement PASS
Class A
2 Radiation disturbance measurement Radiation disturbance Class A PASS
Pst < 1, PIt < 0.65, dc < 3%, dmax
3 Voltage Fluctuations and Flicker PASS
< 4%
Contact Discharge:±6kV
4 Electrostatic discharge immunity Indirect Discharges:±6kV PASS
Air Discharge:±8kV
Test Frequency Test Voltage
Radiated RF
5 80MHz-690MHz 3V PASS
electromagnetic field immunity
690MHz-6000MHz 10V
Electrical fast Mains Test Voltage:±2kV
6 PASS
transient burst immunity Signal lines Test Voltage:±1kV
AC Port Test Voltage:
L-N:±6kV
L-PE,N-PE,L+N-PE:±6kV
7 Surge immunity DC Port Test Voltage: PASS
L-N:±2kV
L-PE,N-PE,L+N-PE:±4kV
Signal lines Test Voltage:±4kV
Test Field Strength:3V/m
8 Immunity to conducted disturbances PASS
Test Frequency:0.15MHz~80MHz
Power frequency magnetic Test Level : 1A/m
9 PASS
field immunity test Criterion A;
Voltage dips>95%, Duration 10ms,
Criterion B;
Voltage dips >95%,
Voltage dips, short interruptions Duration 20ms, Criterion B;
10 PASS
And voltage variations immunity tests Voltage dips 70%, Duration 500ms,
Criterion B;
Voltage reduction >95 %, Duration
5000ms, Criterion C;
4. Evaluation of test results

Criterion A:normal performance within limits specified by the manufacturer, requestor or


purchaser;
Criterion B:temporary loss of function or degradation of performance which ceases after the
disturbance ceases, and from which the equipment under test recovers its normal
performance, without operator intervention;
Criterion C:emporary loss of function or degradation of performance, the correction of which
requires operator intervention;
Criterion D:loss of function or degradation of performance which is not recoverable, owing to
damage to hardware or software, or loss of data.

5. Test Data and Results

5.1 Conducted Disturbance

5.1.1 Standard
EN 55032:2015 + AC:2016 CLASS A:Limits for conducted disturbance at the mains ports of class
A ITE
Frequency range Voltage Limits dB(μV)
MHz Quasi-peak Average
150kHz~0.5MHz 97~87 84~74
0.5~30MHz 87 74
NOTE The limit decreases linearly withthe logarithm of the frequency in the range 0,15 MHz to 0,50
MHz.

EN 55032:2015 + AC:2016 CLASS A:Limits for conducted disturbance at the telecommunication


ports。

Voltage Limits dB(μV) Current Limits dB(μA)


Frequency range
MHz Quasi-pe
Average Quasi-peak Average
ak
150kHz~0.5MHz 97~87 84~74 40~30 30~20
0.5~30MHz 87 74 30 20
NOTE 1 The limits decrease linearly with the logarithm of the frequency in the range 0,15 MHz to 0,5
MHz.
NOTE 2 The current and voltage disturbance limits are derived for use with an impedance stabilization
network
(ISN) which presents a common mode (asymmetric mode) impedance of 150 Ω to the
telecommunication port under test (conversion factor is 20 log10 150 / I = 44 dB).

5.1.2 Test Description


The EUT is laid on a wooden plank of 0.1m height. The mains line through a AMN connected, the
signal line through a ISN to measurement .The distance between EUT and AMN、ISN are 0.8m.

5.1.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57%
Barometric Pressure:101.1kPa

5.1.4 Test Result


5.1.4.1Test Data of 110VAC port Conducted Emission-L

110VAC, L ,PK and AV,Pass

5.1.4.2Test Data of 110VAC port Line Conducted Emission -N


110VAC, N ,PK and AV,Pass

5.1.4.3Test Data of 220VAC port Conducted Emission-L

220VAC, L ,PK and AV,Pass

5.1.4.4Test Data of 220VAC port Line Conducted Emission -N


220VAC, N ,PK and AV,Pass

5.1.4.5Test Data of -48VDC port Conducted Emission -48V

-48VDC, -48V,PK and AV,Pass

5.1.4.6Test Data of -48VDC port Conducted Emission -0V


-48VDC, 0V,PK and AV,Pass

5.1.4.9Test Data of GE port Conducted Emission

-48VDC,GE,PK and AV,Pass

5.2 Radiation Disturbance Measurement

5.2.1 Standard
EN 55032 : 2015 + AC : 2016 CLASS A : Limits for radiated disturbance of class A ITE at a
measuring distance of 3m
Frequency range Quasi-peak limits
MHz dB(μV/m)
30~230MHz 50
230MHz~1GHz 57
NOTE 1 The lower limit shall apply at the transition frequency.

EN 55032:2015 + AC:2016 CLASS A: CLASS A:Limits for radiated disturbance of class A ITE
at a measuring distance of 3m
Frequency range MHz AV/dB(uV/m) PK/dB(uV/m)
1~3GHz 60 80
3GHz~6GHz 64 84
NOTE 1 The lower limit shall apply at the transition frequency.

5.2.2 Test Description


Test site is anechoic chamber. The EUT is laid on a wooden plank of 0.1m height. The EUT keep
normal operation state. The EUT distance from antenna 3m. For measurement, the position of antenna
is varied between 1m and 4m height , antenna oriented for both horizontal and vertical polarization.
The turntable is rotated fully for maximum indication at each test frequency.

5.2.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.2.4 Test Result


5.2.4.1 Test Data of Radiation Emission (antenna horizontal polarization)-220VAC

30-1000MHz Antenna Horizontal Polarization,pass


30-1000MHz Antenna Vertical Polarization,pass
5.2.4.2Test Data of Radiation Emission (antenna horizontal polarization)-110VAC

30-1000MHz Antenna Horizontal Polarization ,pass


30-1000MHz Antenna Vertical Polarization ,pass
5.2.4.3Test Data of Radiation Emission (antenna horizontal polarization)--48VDC

30-1000MHz Antenna Horizontal Polarization ,pass


30-1000MHz Antenna Vertical Polarization ,pass
5.2.4.4Test Data of Radiation Emission (antenna horizontal polarization)-220VAC

1000-6000MHz Antenna Horizontal Polarization ,pass


1000-6000MHz Antenna Vertical Polarization ,pass

5.3 Voltage Fluctuations and Flicker

5.3.1 Standard
ETSI EN 300 386 V 2.1.1 (2016-07): 2008 EN 61000-3-3: 2013

5.3.2 Test Procedure


The test supply voltage AC 230V. The observation period for Pst is 10min and PIt is 2h.

5.3.3 Ambient Conditions


Temperature:23℃
Relative Humidity: 59%
Barometric Pressure: 101.1kPa

5.3.4 Test Results


The EUT passed the Voltage Fluctuations and Flicker requirements.

Test Port Limits Test Data Pass/Fail

Mains Pst < 1 0.023 Pass

Mains PIt < 0.65 0.03 Pass

Mains dc < 3% 0.01% Pass

Mains dmax < 4% 0.04% Pass


5.4 Electrostatic Discharge Immunity Test

5.4.1 Standard
EN 61000-4-2:2009

5.4.2 Test Procedure


The EUT is laid on a wooden plank of 0.1m height. the EUT keep normal operation state. The set-up
and test method are according to EN 61000- 4-2. All user accessible conductive surfaces (Test points)
were subjected to air discharges 8 kV,contact discharges and indirect discharges of 6 kV where
discharges occurred the discharge was then applied a total of 20 times to each test point, 10 positive
discharges and 10 negative discharges.

5.4.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.4.4 Test Results


The EUT passed the electrostatic discharge immunity tests as required by specification. Performance
criterion B.

Air Discharges Contact Discharges Indirect Discharges EUT


Test Port
Test Voltage Test Voltage Test Voltage Performance

HCP N/A N/A ±6kV B

VCP N/A N/A ±6kV B

Left N/A ±6kV N/A B

Right N/A ±6kV N/A B

Top N/A ±6kV N/A B

Front N/A ±6kV N/A B

Signal Port N/A ±6kV N/A B

Optical Fiber ±8kV N/A N/A B


5.5 Radiated Electric Fields Immunity Test

5.5.1 Standard
EN 61000-4-3:2006 + A1:2008 + A2:2010

5.5.2 Test Procedure


Test site is anechoic chamber. The EUT is laid on a wooden plank of 0.1m height. The set-up and test
method are according to EN 61000-4-3. The distance of the test is 3m. All sides of the EUT (front,
behind, left and right) are tested by antenna in vertical and horizontal polarization. The EUT was
subjected to a field strength, the amplitude modulated, 80% by 1 kHz sine signal,where the frequency
is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the
preceding frequency value.

5.5.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.5.4 Test Results


The EUT has met the requirements of immunity to radiated electric fields .

Test Port Test Frequency/Test Field Strength Antenna Polarization EUT Performance

Horizontal A
80MHz-690MHz , 3V
Enclosure
690MHz-6000MHz , 10V Vertical A

5.6 Electrical Fast Transient Bursts Immunity Test

5.6.1 Standard
EN 61000-4-4:2004+ A1:2010

5.6.2 Test Procedure


The EUT is laid on a wooden plank of 0.1m height. The set-up and test method are according to EN
61000-4-4. The mains test voltage was 2 kV, the signal Lines test voltage was 1 kV and test frequency
5 kHz was applied for 1 minute to each line, in negative and positive polarities.
5.6.3 Ambient Conditions
Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.6.4 Test Results


The EUT has met the requirements of Immunity to Electrical Fast Transient Bursts. Performance
criterion B .
Test Port Test Voltage Coupling Mode EUT Performance
220VAC Port ±2kV CDN B
-48VDC Port ±2kV CDN B
GE ±1kV Coupling Clamp B

5.7 Surges Immunity Test

5.7.1 Standard
EN 61000-4-5:2006 and ITU K.21:2003

5.7.2 Test Procedure


The EUT is laid on a wooden plank of 0.1m height. The set-up and test method are according to EN
61000-4-5, ITU K.21. The Mains was subjected to transient signals of the form of double exponential
waves 1.2 /50µs & 8/20µs. The signal Lines was subjected to 10/700µs and double exponential waves
1.2 /50µs & 8/20µs waves in line-GRD. The surges were injected in both positive and negative
polarities. At least five surges were applied at each polarity. The surge repetition rate was 1 minute.

5.7.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.7.4 Test Results


The EUT has met the requirements of Immunity to Surges. Performance criterion B .
Test Voltage
Combination
kV/Test EUT
Test Port wave Standard
Current kA Performance
Tr/Th us kV
220VAC Port L-N 1.2/50 ±6kV EN B
R 2Ω 61000-4-5
L-PE ±6kV
1.2/50
N-PE ±6kV
R 12Ω
L+N-PE ±6kV
1.2/50 ±2kV
L-N
R 2Ω
EN
-48VDC Port L-PE ±4kV B
1.2/50 61000-4-5
N-PE ±4kV
R 12Ω
L+N-PE ±4kV
10/700
8Lines-PE ±4kV ITU K.21
R (25/8+15)Ω
GE B
10/700
Line-Line ±0.5kV ITU K.21
R (25+15)Ω

5.8 Immunity To Continuous Conducted Disturbances

5.8.1 Standard
EN 61000-4-6:2009

5.8.2 Test Procedure


The EUT is laid on a wooden plank of 0.1m height. The set-up and test method are according to EN
61000-4-6. The disturbance signal is 80% amplitude modulated with a 1kHz sine wave. The rate of
sweep shall not exceed 1.5×10-3 decades/s, where the frequency is swept incrementally, the step size
shall not exceed 1% of the start and thereafter 1% of the preceding frequency value.

5.8.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.8.4 Test Results


The EUT has met the requirements of Immunity to Continuous Conducted Disturbances. Performance
criterion A .
EUT
Test Port Test Voltage Test Frequency Coupling Mode
Performance

220VAC Port 3V 0.15MHz~80MHz CDN A


-48VDC Port 3V 0.15MHz~80MHz CDN A

GE 3V 0.15MHz~80MHz Clamp A

5.9 Power frequency magnetic field immunity test

5.9.1 Standard
EN 55035:2017 EN 61000-4-8:2010

5.9.2 Test Procedure


Measurement was performed in full-anechoic chamber.
Measurement and setting of EUT was applied according to EN 61000-4-8:2010

5.9.3 Ambient Conditions


Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.9.4 Test Results


Observation: The EUT continued to operate as intended
Conclusion: The EUT meet the requirements of Criterion A.

Test No. Level A/m Frequency Hz Axis EUT erformance


1 1 50/60 X A
2 1 50/60 Y A
3 1 50/60 Z A

5.10 Voltage Dips Immunity Test

5.10.1 Standard
ETSI EN 300 386 V 2.1.1 (2016-07) EN 55035:2017 EN 61000-4-11: 2004

5.10.2 Test Procedure


The test supply voltage AC 230V.
5.10.3 Ambient Conditions
Temperature:25℃
Relative Humidity:57 %
Barometric Pressure:101.1kPa

5.10.4 Test Results


The EUT passed the Voltage Dips Immunity Test.

Level UT td N EUT Performances

1 >95% 10ms 3 B

2 >95% 20ms 3 B

3 30% 500ms 3 B

4 >95% 5000ms 3 C