Вы находитесь на странице: 1из 10

Nystagmus We manufacture Nystagmus

Spectacles by Prof. Frenzel in


Type 501
Nystagmus Spectacle with
Spectacles four variations: fixed lenses.

by Prof. Frenzel Type 502


Nystagmus Spectacle with
hinged lenses.

Type 503
Nystagmus Spectacle with fixed
battery-attachment and lenses.

Type 703
Nystagmus Spectacle with
variable connection capabilities.

Medizin-Technische Produktions GmbH & Co. KG  Göttingen


Nystagmus Type 501 Nystagmus Spectacle with:

Spectacle
by Prof. Frenzel - fixed lenses

- fixed connection wire

- Clip-head strap

Medizin-Technische Produktions GmbH & Co. KG  Göttingen


Nystagmus Spectacle with fixed lenses by Prof. Frenzel

Type 501

Modern vestibular diagnostic demands a high degree of precision in the search for
spontaneous and provoked nystagmus. In many cases, a correct diagnosis may only
be achieved by using the complicated technology of electronystagmography (ENG).
The new nystagmus glasses by Prof. Frenzel represent an easy to handle alternative.
The examination with interior spectacles illumination takes place in a darkened room.
Through the interior illumination of the spectacles the patient´s optical contact to its
environment will be interrupted (elimination of the nystagmus-hindering fixation).
At the same time the highly illuminated eyes are easily observable under magnifying
glasses. By this, pathological nystagmus reaction is very often traceable when looking
straight on, which without spectacles, even when looking sideways, is not clearly
or not at all distinguishable.
Fig. 1: Nystagmus Spectacle Type 501

Clip-head strap DEHAG-Regulating Transformer DEHAG-Battery Container


Type 5.01.08 Type 505 Type 504

Fig. 2: Clip-head strap Type 5.01.08 Fig. 4: DEHAG-Regulating Transformer Type 505 Fig. 5: DEHAG-Battery Container Type 504

The clip-head strap provides a secure The DEHAG-Regulating transformer In order to allow a usage independent
fixation of the spectacle in front of the facilitates the power supply of the of the power supply, alternatively
patient´s eyes and facilitates an easy nystagmus spectacle. the Nystagmus Spectacle can be
search for spontaneous and provoked Next to the on-off switch on the back supplied with power through the
nystagmus e.g. through shaking the a switch for the reduction of luminous DEHAG-Battery container. It can be
head, storing or examinations on intensity can be found at the front. The operated with three 1.5 Volt batteries,
swivel-chaires. luminous diode next to it states the size C LR14/AM-2 (baby cells).
The clip-head strap can be removed condition of the DEHAG-Regulating (Batteries are not subject of the offer).
from the slits of the Nystagmus transformer (luminous-reduced).
Spectacle by slightly pressing it
together. Replacement lamp
Type 507

Replacement cover
Type 57.00.02

The Nystagmus Spectacle


may only be operated with
4 Volt maximally!

Fig. 6: Replacement lamp Type 507

The Nystagmus Spectacle Type 501


can be operated with a 4 Volt; 0.23
Fig. 3: Replacement cover Type 57.00.02 Ampere; 1 Watt replacement lamp.
(Thread diameter: 3.5 x 0.35mm).
The cover ensures the shielding of the
light bulb.

DEHAG Medizin-Technische Tel: 0551 / 32519


Produktions GmbH & Co. KG Fax: 0551 / 376106
Reinhard - Rube - Straße 10a Email: info@dehag.com
D-37077 Göttingen Internet: www.dehag.com
Nystagmus Type 502 Nystagmus Spectacle with:

Spectacle
by Prof. Frenzel - hinged lenses

- fixed connection wire

- fixed head strap

Medizin-Technische Produktions GmbH & Co. KG  Göttingen


Nystagmus Spectacle with hinged lenses by Prof. Frenzel

Type 502

Modern vestibular diagnostics demands a high degree of precision in the search


for spontaneous and provoked nystagmus. In many cases, a correct diagnosis may
only be achieved by using the complicated technology of electronystagmography
(ENG).
The new nystagmus glasses by Prof. Frenzel represent an easy to handle
alternative.
The examination with interior spectacles illumination takes place in a darkened room.
Through the interior illumination of the spectacles the patient´s optical contact to its
environment will be interrupted (elimination of the nystagmus-hindering fixation).
Fig. 1: Nystagmus Spectacle Type 502 closed At the same time the highly illuminated eyes are easily observable under magnifying
glasses. By this, pathological nystagmus reaction is very often traceable when looking straight on, which without spectacles,
even when looking sideways, is not clearly or not at all distinguishable.

Nystagmus Spectacle DEHAG-Regulating Transformer DEHAG-Battery Container


Type 502 Type 505 Type 504

Fig. 2: Nystagmus Spectacle Type 502 open Fig. 4: DEHAG-Regulating Transformer Type 505 Fig. 5: DEHAG-Battery Container Type 504

With the lenses turned up and the The DEHAG-Regulating transformer In order to allow a usage independent
room illumination switched on, eye facilitates the power supply of the of the power supply, alternatively
observation with maintained fixation nystagmus spectacle. the Nystagmus Spectacle can be
is possible: e.g. the Hallpike-technique Next to the on-off switch on the back supplied with power through the
of termal examination. After switching a switch for the reduction of luminous DEHAG-Battery container. It can be
off room illumination and hinging down intensity can be found at the front. The operated with three 1.5 Volt batteries,
the lenses, an immediate change-over luminous diode next to it states the size C LR14/AM-2 (baby cells).
into the actual luminous spectacle condition of the DEHAG-Regulating (Batteries are not subject of the offer).
examination with elimination of fixation transformer (luminous-reduced).
may be started.
Replacement lamp
Type 507
Replacement cover
Type 5.02.16

The Nystagmus Spectacle


may only be operated with
4 Volt maximally!

Fig. 6: Replacement lamp Type 507

Fig. 3: Replacement Cover Type 5.02.16 The Nystagmus Spectacle Type 502
can be operated with a 4 Volt; 0.23
The cover ensures the shielding of the Ampere; 1 Watt replacement lamp.
light bulb. (Thread diameter: 3.5 x 0.35mm).

DEHAG Medizin-Technische Tel: 0551 / 32519


Produktions GmbH & Co. KG Fax: 0551 / 376106
Reinhard - Rube - Straße 10a Email: info@dehag.com
D-37077 Göttingen Internet: www.dehag.com
Nystagmus Type 503 Nystagmus Spectacle with:

Spectacle
by Prof. Frenzel - fixed lenses

- adjustable batterie hold

Medizin-Technische Produktions GmbH & Co. KG  Göttingen


Nystagmus Spectacle with battery hold and fixed glasses by Prof. Frenzel

Type 503

Modern vestibular diagnostic demands a high degree of precision in the search for
spontaneous and provoked nystagmus. In many cases, a correct diagnosis may only
be achieved by using the complicated technology of electronystagmography (ENG).
The new nystagmus glasses by Prof. Frenzel represent an easy to handle alternative.
The examination with interior spectacles illumination takes place in a darkened room.
Through the interior illumination of the spectacles the patient´s optical contact to its
environment will be interrupted (elimination of the nystagmus-hindering fixation).
At the same time the highly illuminated eyes are easily observable under magnifying
glasses. By this, pathological nystagmus reaction is very often traceable when looking
straight on, which without spectacles, even when looking sideways, is not clearly or not
at all distinguishable.
Fig. 1: Nystagmus Spectacle Type 503

Nystagmus Spectacle Detail view Replacement lamp


Type 503 adjustable battery hold Type 507

Fig. 2: Nystagmus Spectacle Type 503 Fig. 3: adjustable battery hold Fig. 4: Replacement lamp Type 507

With the Nystagmus Spectacle Type Thanks to the adjustable battery hold The Nystagmus Spectacle Type 503
503 you can easily carry out short- you have the opportunity to adjust can be operated with a 4 Volt; 0.23
term examinations at the patient. This the illumination individually through a Ampere; 1 Watt replacement lamp.
model allows wireless working and slight turn around of the switch. (Thread diameter: 3.5 x 0.35mm).
is not bound to power supply. The
Nystagmus Spectacle is provided with
power through the adjustable battery Replacement cover
hold above the spectacle and require Type 57.00.02
three 1.5 Volt batteries, size C LR14/
AM-2 (baby cells).
(Batteries are not subject of the
offer).

Fig. 5: Replacement cover Type 57.00.02

The cover ensures the shielding of the


light bulb.

DEHAG Medizin-Technische Tel: 0551 / 32519


Produktions GmbH & Co. KG Fax: 0551 / 376106
Reinhard - Rube - Straße 10a Email: info@dehag.com
D-37077 Göttingen Internet: www.dehag.com
Nystagmus Type 703 Nystagmus Spectacle with:

Spectacle
by Prof. Frenzel - fixed lenses

- Bajonet interlocking

- adjustable battery hold

- universal applicable

Medizin-Technische Produktions GmbH & Co. KG  Göttingen


Nystagmus Spectacle with Bajonet interlocking and battery hold by Prof. Frenzel

Type 703

Modern vestibular diagnostics demands a high degree of precision in the search


for spontaneous and provoked nystagmus. In many cases, a correct diagnosis may
only be achieved by using the complicated technology of electronystagmography
(ENG).
The new nystagmus glasses by Prof. Frenzel is especially suitable for short-term
examinations. Thanks to the new bajonet connection and the different connection wires,
the Nystagmus Spectacle can be quickly transformed into spectacle that are suitable
for various examination e.g. for storing or examinations on swivel-chairs. By using
the corresponding components the Nystagmus Spectacle come up to the individual
expectations of the doctor.
The examination with interior spectacles illumination takes place in a darkened room.
Through the interior illumination of the spectacles the patient´s optical contact to its
environment will be interrupted (elimination of the nystagmus-hindering fixation).
Fig. 1: Nystagmus Spectacle Type 703 At the same time the highly illuminated eyes are easily observable under magnifying
glasses. By this, pathological nystagmus reaction is very often traceable when looking straight on, which without spectacles,
even when looking sideways, is not clearly or not at all distinguish.

Connection wire DEHAG Bajonet wire Clip-head strap


Type 7.03.06 Type 7.03.05 Type 5.01.08

Fig. 2: Connection wire DEHAG Type 7.03.06 Fig. 4: Bajonet wire Type 7.03.05 Abb. 6: Clip-head strap Type 5.01.08

In order to provide the Nystagmus The bajonet wire Type 7.03.05 Should one of the variety of wires be
Spectacle with power, you can use connects the Nystagmus Spectacle used, the clip-head strap ensures
the connection wire Type 7.03.06 to with the battery hold and thus allows a secure fixation of the Nystagmus
connect it with the bajonet connection. a mobile and flexible working inde- Spectacle in front of the patient´s
After that it can be connected with the pendent of the power supply. In this eyes. This allows an easy search for
DEHAG-Regulating transformer or with combination it is especially ideal for spontaneous and provoked nystag-
the DEHAG-Battery container instead of examinations on swivel-chairs. mus, e.g. through shaking the head,
using the battery hold. storing or examinations on swivel-
chairs.
The clip-head strap can be removed
from the slits of the Nystagmus
Replacement cover Replacement lamp
Spectacle by slightly pressing it
Type 57.00.02 Type 507
together.

The Nystagmus Spectacle


may only be operated with
4 Volt maximally!
Fig. 3: Replacement cover Type 57.00.02 Fig. 5: Replacement lamp Type 507

The cover ensures the shielding of The Nystagmus Spectacle Type 703
the light bulb. can be operated with a 4 Volt; 0.23
Ampere; 1 Watt replacement lamp.
(Thread diameter: 3.5 x 0.35mm).

DEHAG Medizin-Technische Tel: 0551 / 32519


Produktions GmbH & Co. KG Fax: 0551 / 376106
Reinhard - Rube - Straße 10a Email: info@dehag.com
D-37077 Göttingen Internet: www.dehag.com

Вам также может понравиться