CW / ACW Motors

SN Details ACW Motor CW Motor


1. Manufacturer Marathon Electric Hyundai Heavy Ind. Co. Ltd
2. Type, frame size & Design code No. Vertical Sq. Cage Induction CACW/1000Fr/IEC60034
Motor, DCV450U Frame
3. Quantity
4. Specification & Code IS:325 / IEC-34 IS:325 / IEC-60034
5. Rated Output
a. At 40oC Ambient kw 720 4077
b. At 50oC Ambient kw 700 3850
8. Type of enclosure CACA/IC6A1A1 type of CACW /IC81W
cooling
9. Degree of Protection IP-55 IP-55
10. Phase, frequency and voltage 3-phase, 50 Hz, 3300 V 3-phase, 50 Hz, 11000 V
11. Permissible variation % V : ±10, F: : ±5, V : ±10, F: : ±5,
Combine: 10 absolute Combine: 10 absolute
12. Full load current A 155.5 247.6
13. No load current (±10% tolerance) A 58 103
14. Full Load Speed rpm 741 330
15. Rated Power Factor 0.83 0.85
16. Connection Star Star
17. Resistance per phase at 20oC Ω 0.1054 0.2
18. Inductance per phase 0.0106 henry 13.5 mH
19. Capacitance per phase µf 0.0664 0.214
20. Torque at full load kgm 924 11363.3
21. Safe stall time Hot Motor Cold Hot Motor Cold Motor
Motor
a. Rated Voltage sec 15 20 16 21
b. 80% Voltage sec 25 30 25 32
c. 110% Voltage sec 12 16 14 17
25. Insulation
a. Class ‘F’ with temp rise limited ‘F’ with temp rise limited to
to Cl’B’ Cl’B’
b. Material & Treatment of Mica based resin poor VPI MICA resin poor with VPI &
insulation F insulation
28. Temp. rise over 50oC ambient o
C 70 70
29. Impulse voltage withstand kVp 18.2 49
30. Stator thermal time constant min 90 60
31. Bearing details
32. a. Number DE: NU228, NDE:QJ320
b. Type DE: Rollor, NDE: Ball DE: Ball, NDE: Thrust &
Guide(Spherical thrust
rollor)
c. Life at rated speed hr 40000 Over 40000
d. RTD 6 wire PT100, Duplex 3 wire PT100,
36. CT for Diff. Prot. No 400/1A, CL: PS, Vk:
≥10(Rct+12), Ie: ≥30mA at
Vk