Вы находитесь на странице: 1из 48

Standard Details for Metal

Roofing & Siding

Post Frame
and
Residential Structures

www.fabral.com
Table of Contents
Installation Instructions 2-3
Paint System & Warranties 4
Steel Panel Profiles 5-6
Aluminum Panel Profiles 7
Post Frame Estimating & Roof Types 8
Post Frame Building Details 9
Post FrameFlashings/Trim 10 - 13
Post Frame Trim Details: 13 - 30
Box Gable - 13
Endlap & Rain Carrying Table - 14
Eaves - 15-16
Ridges - 16-18
Gables - 18-19
Flying Gable - 20
Endwall - 21
Sidewall & Valley - 22
Gambrel & Transition - 23
Outside Corner - 24
Inside Corner & Base Guard - 25
Door Jambs & Headers - 26-29
Translucent Panels - 29
Window Details - 30
Residential Building Details 31
Residential Load Tables & Profiles 32
Residential Flashings/Trim 33
Residential Trim Details: 34 - 43
Ridges - 34
Eaves - 35
Gable & Endwall - 36
Sidewall & Gambrel - 37
Transition & Pipe Boot - 38
Skylight & Chimney - 39-41
Dormer Details - 42-43
Accessories 44
**Due to Product improvements, changes and other factors, Fabral reserves the right to change or delete infor-
mation herein without prior notice or obligation to make changes in products previously purchased.
Installation Instructions
Building Design and Construction fastener spacing and larger diameter #14 screws. (Refer to the tables
In order to ensure the anticipated performance and longevity, on page 31).
protect metal panels from potentially corrosive situations and materials. On re-roofing projects where the condition of the old decking
When treated lumber will be in direct contact with metal panels or flash- is in question, or where existing shingles will be left in place, new 2x4
ings please note the following: Galvanized steel is compatible with the purlins should be fastened through the decking and into the rafters. This
CCA (Chromated Copper Arsenate) pressure-treated lumber that was will provide a solid framework for attaching the metal panels. For more
predominantly used before 2004, but not with the older Penta treated detailed information on Re-roofing applications, consult FABRAL Tech-
lumber or the new ACQ (Alkaline Copper Quartenary), CA (Copper nical Bulletin #721, Re-Roofing With Metal. Load tables are available for
Azole), or CBA (Copper Boron Azole). Stainless steel or other special all FABRAL panels; contact FABRAL for additional information.
treated fasteners should be used into these non-compatible pressure
treated lumbers. Aluminum must be separated from contact with all Roofing
treated wood since the soluble copper in the preservative is corrosive to Panel sidelaps should face away from wind driven rain. To
aluminum. Likewise, dissimilar metals also require a protective barrier accomplish this, begin by installing the first sheet square with the
between them to prevent galvanic corrosion. Request FABRAL Techni- eave and gable at the down wind end of the roof, farthest away from
cal Bulletins #803, 106, and 107 for more information on treated lumber the source of prevailing winds.
and dissimilar metals. In applications requiring a panel endlap, please refer to the
Plastic, builders’ felt, bituminous paint, caulking, or gas- detailed instructions in this booklet. For best results, lap panels as
ket material may be used to separate panels from treated wood shown and install in the indicated sequence. All endlaps require seal-
and dissimilar metals. When using aluminum panels in direct contact ant. When weather-tightness is critical, use sealant tape in all side-
with steel, use a separator as described above and fasten with Stain- laps.
less Steel screws. To provide a drip edge, allow an overhang of 1 to 2 inches at
Fertilizer, lime, acids, feeds, manure, soils, and many other the eave. At the gable edge, use a gable or sidewall flashing. This will
compounds also cause corrosion in metal panels. Contact between keep weather out, prevent lifting in high winds, and provide a neat, fin-
metal panels and any potentially corrosive materials should be pre- ished appearance. The trim and roofing sheet should be fastened every
vented. 12 to 24 inches along the gable edge.
Porous insulation materials may absorb and retain moisture,
and should not be used in direct contact with metal panels. Use a vapor Roof Pitch
barrier such as polyethylene plastic or 30-lb felt to prevent moisture The metal roofing panels shown in this manual require a mini-
from contacting both the insulation and the metal panel. mum slope of 2½” per foot to ensure proper drainage. Refer to the rain-
FABRAL’s translucent panels are intended for siding applica- carrying table in this booklet for the maximum allowable panel length per
tions only. In all situations, foot traffic should be avoided on translucent slope that will provide adequate drainage. For longer slopes and lower
panels. Translucent panels used in roofing applications will break down roof pitches, contact FABRAL for other suitable profiles.
in a short time and cause staining and premature corrosion of the metal
panels below. If used on roofs, apply butyl caulking to separate the Bending and Bowing
fiberglass panels from the metal. Translucent panels should be cleaned Aluminum roofing and siding sheets are rollformed from hard-
and sealed regularly, as recommended by the translucent panel manu- ened, tempered metal for maximum strength. If a sheet must be bent,
facturer. a gentle 90-degree bend is the maximum recommended. Metal should
not be re-bent once it has been formed, nor should it be folded back on
Purlins, Girts and Roof Deck itself. When a metal roofing sheet must be installed on a curved roof,
The substructure to which the metal panels are fastened must screws should be installed at every overlapping rib at the sheet ends
be properly spaced and sufficiently thick to provide a roof or wall system to resist the natural tendency of the metal to spring back. The standard
able to meet required design loads. fastening pattern is permitted over the rest of the sheet. When installing
A 2” nominal lumber thickness provides the maximum pullout the metal panels shown in this booklet over a curved arch, the minimum
values for both screws and nails when the fasteners penetrate a radius of the arch is 18’ for aluminum panels and 24’ for steel panels.
minimum of 1” into the wood. Since 1” nominal lumber and solid decking Use sealant tape or butyl caulking at all sidelaps and endlaps.
are thinner, they provide somewhat lower pullout values. When using Additional care and fasteners must be provided when securing the top
purlins, FABRAL recommends a maximum spacing of 24” on-center and bottom purlins on an arched rafter building to prevent the curved
(note that 5V requires solid decking). Pullout values decrease if the panels from pulling the purlins loose from the rafters. Ring-shank pole
fasteners protrude completely through the purlins. Kiln-dried softwood barn nails, heavy wood screws, lag screws, or bolts are often used for
is recommended for purlins or decking (pine, fir, hemlock, and spruce). attaching these purlins.
Hardwoods are difficult to fasten into without splitting and contain tannic
acids that are corrosive to metal panels. Green (non-kiln-dried) lumber Siding
may warp, twist, and shrink as the wood seasons fully, causing wavi- Siding should be installed using the standard fastening and
ness in the panels as well as loosening and leaking of the fasteners. overlap patterns to ensure optimum performance. For strong, neat cor-
Solid decking is highly recommended for all residential ap- ners use hemmed corner flashings. Do not run siding sheets all the
plications. When usingsolid decking or sheathing, always use 30-lb felt way to the ground. Instead, provide a protective base of concrete,
or underlayment and plan on using closer masonry, treated wood, or similar material and terminate the siding
sheets 6” above grade.
2
Installation Instructions
If siding sheets are installed horizontally, use sealant tape or Refer to the SMACNA Architectural Sheet Metal Manual
butyl caulking at the vertical laps to ensure weather-tight joints. Install for additional information about detailing and installing
panels from the bottom up so that water is directed away from, and not flashings.
into, the lap joints.
Safety
Fastening Always work safely when installing metal products and use
FABRAL can supply either screws or nails for fastening into extreme caution on the roof at all times. Wear gloves and safety glass-
dimension lumber, with screws offering better pullout values. Always es to reduce the risk of injury, and use hearing protection when operat-
use screws with solid sheathing. Screws for use with steel panels are ing power tools. Always be sure that ladders are safely positioned and
galvanized and then coated with an organic polymer for optimum cor- properly secured. Safety harnesses or other special equipment may
rosion resistance. For best results with aluminum panels, use #300 be required; be sure to Consult OSHA guidelines for compliance with
series stainless steel screws. all safety requirements.
The FabrOseal® galvanized ring-shank nail, with its premium Do Not walk on panels until all the fasteners are installed.
long-life silicone rubber gasket, assures a lasting seal and is the best Metal roofing panels are slippery when wet, dusty, frosty, or oily -- Do
nail available for steel panels when screws are not desired. Not attempt to walk on a metal roof under these conditions. Wear soft-
The correct way to fasten steel panels with nails is to drive soled shoes to improve traction and to minimize damage to the paint
the nail through the top of the rib so the washer is compressed securely finish. Always be aware of your position on the roof relative to any roof
against the metal. Nail placement must be in the ribs for roofing ap- openings, roof edges, co-workers, and penetrations. Installing metal
plications to minimize the potential for roof leaks. Over-driving the nail panels or flashings on a windy day can be dangerous and should be
can split the washer and dimple the metal, causing leaks. avoided if possible.

Cutting Aluminum Panels


To make a cut parallel to the ribs, score the panel deeply with
a sharp utility knife and bend back-and-forth along the score, breaking
Correct Under-Driven Over-Driven the metal off cleanly. For cuts across the ribs, use straight-cut snips,
electric or pneumatic shears, a portable profile shear, or an electric
nibbler. Some installers prefer using a circular saw with a metal cutting
Wood screws with combination metal and neoprene washers blade (a fine-tooth hardwood blade, or a standard combination blade
should be installed in the flat area of the panel adjacent to the ribs, and reversed in the saw works also). Light oil or soap on the blade will
tightened such that the washer is compressed as illustrated above. This make cutting easier.
will ensure a lasting, leak-proof seal. Remove any metal filings created
by the drilling action of the screws to avoid rust staining on the panel Cutting and Drilling Steel Panels
surface. Refer to the fastening schedules in this booklet for the correct Steel panels may be cut with metal snips, electric or pneu-
fastener locations. matic shears, a portable profile shear, or an electric nibbler. Some
installers prefer using a circular saw to cut metal panels. Do Not use
Flashing and Trim self-consuming abrasive blades because of the following: 1. Abrasive
Always begin flashing installation from the bottom and work blades burn the paint and galvanizing at the cut edge, leaving edg-
up, so that upper flashings are lapped on top of lower flashings. This will es that are jagged and unsightly and rust more quickly 2. Abrasive
prevent moisture from leaking under the flashings and into the structure. blades produce hot metal filings that embed in the paint and cause rust
Endlap flashings a minimum of 6” and seal the lap joints with sealant. marks on the face of the panel 3. All saw cut panels must be turned
Extend flashings 4-6” beyond the building, cut along the bend lines, ap- face down and cut in a location down-wind and well away from the
ply sealant, and fold the side flaps in and the top flaps down to cap off building and other panels to avoid embedment of metal filings on other
the ends. Secure with pop-rivets or stitch screws. panels 4. All saw cut panels must be thoroughly wiped to ensure the
Some roof conditions, such as valleys, may require a longer removal of all metal filings. If saw cutting cannot be avoided, select a
endlap and/or a larger flashing to properly drain moisture from the roof. carbide-tipped blade specially designed for cutting light-gage ferrous
Factors that influence flashing size, shape, and endlap requirements metal panels. These blades are now available at many home centers
include roof pitch, roof geometry, slope length, and climatic factors (such and lumber yards. Pre-drilling wall panels gives uniform alignment of
as heavy snowfall or rainfall). screw rows. Be sure to remove drill filings once panels are installed to
Whenever possible, begin trim installation at the downwind avoid rust marks from the filings.
end of the roof, farthest away from the source of prevailing winds, to al-
low flashing laps to face away from wind-driven rain. Refer to the details Building Maintenance
in this book for the proper location of fasteners and sealants. A metal roof should be inspected annually and cleaned as necessary
The flashings and trims shown in this book are standard parts. to maintain its beauty and performance. Any debris or residue, includ-
Custom trims are available to meet your specific design needs. If you ing leaves, twigs, and dust should be cleaned off promptly to prevent
need a special trim, please furnish a drawing of the desired shape, in- moisture entrapment against the metal, which may lead to finish dete-
cluding dimensions and angles, to your Fabral dealer to obtain pricing rioration or premature corrosion. Flashings may need to be re-sealed
and availability. periodically in order to maintain optimum weathertightness.

3
Paint System & Warranties
Enduracote™ is a paint system that takes performance to the next level. Based on
cutting edge resin technology, this system offers unbeatable durability and superior
long-term performance against the elements.

The Enduracote™ Warranty


• Lifetime film integrity for walls & roofs
• 30-year against fade & chalk Top
TOP Coat
COAT
Primer CoatCOAT
• 10-year edge rust against acid rain Sealer
PRIMER
Coat
SEALER COAT
For profiles: Grand Rib 3®, Alu-Tuff II, 5V Crimp, ProClad, Zinc Pre-Treatment
ZINC PRE-TREATMENT
StrongClad, Mighti-Rib® Protective Metallic Barrier
GALVANIZED

Bare
BARE Steel
STEEL

The Enduracote™ PLUS Warranty


• Lifetime film integrity for walls & roofs
• 30-year against fade & chalk
• 15-year edge rust against acid rain
• 25-year non-perforation against acid rain
for walls; 20-years for roofs Backer Coat
BACKER COAT

For profiles: Grand Rib 3® PLUS, Alu-Tuff, 1 1//2” SSR, Primer


PRIMER Coat
COAT

Climaguard™ Sealer
SEALER Coat
COAT

Zinc
ZINC Pre-Treatment
PRE-TREATMENT
Protective
GALVANIZEDMetallic Barrier

Example of the Grand Rib 3® layer system


GRANDRIB 3® , ALU-TUFF II, 5V, PRIME RIB, STRONGCLADTM
26 GAGE MIGHTI-RIB & ULTRA-RIB PANELS
LIMITED LIFETIME ENDURACOTETM PAINT WARRANTY

PERFORMANCE GUARANTEE
Fabral, a Euramax Company, Lancaster, PA, hereinafter referred to as "Fabral" or "Seller," guarantees that within the continental United States
normal outdoor atmospheric conditions (which term excludes corrosive or aggressive atmospheres including, but not limited to those contaminated
TM
Example Warranty Form
with chemical fumes or salt spray) will not cause the exterior side paint on the ENDURACOTE galvanized steel roofing and siding panels sold to

Other Warranties
you under this guarantee to:

1. Crack, check, or peel for the lifetime of the building for sidewall panels and roofing panels.
NOTE: A crack is a break in the coating sufficiently deep that the underlying surface is visible. Checking refers to shallow breaks in the coating
which do not expose the underlying surface. Peeling occurs when the coating actually comes off the metal in pieces. Slight crazing or cracking
may occur on roll formed edges or break bends at the time of forming and should be considered as standard and shall not constitute a basis for
complaint under this warranty. However, the film will not lose adhesion to the substrate when cellophane tape applied at the bend is removed.

2. Chalk in excess of a numerical rating of eight (8) for vertical siding panels or a numerical rating of six (6) for roofing and non-vertical siding

Polyester Paint Warranty


panels for a period of thirty (30) years when measured in accordance with the standard procedure specified in ASTM D-4214 (latest).
NOTE: Chalk refers to the formation of loose, removable powder evolved from the coating itself upon breakdown of its resin or binder. The test
merely utilizes dark or light colored felt rubbed against the surface to pick up a measurable amount of the chalk which is then compared to a
standard. On a scale of 10 (best) to 0 (worst), a rating of eight is considered a moderate amount of chalk, while a rating of two would represent
extreme chalk.

3. Fade or change in color in excess of five (5) units of color difference (Hunter ¨E units) for vertical siding panels or in excess of seven (7) units of
color difference (Hunter ¨E units) for roofing and non-vertical siding panels for a period of thirty (30) years when measured in accordance with the
standard procedure specified in ASTM D-2244 (latest) paragraph 4.3, on a washed test area.
• 25-year limited film integrity
• 10-year against fade & chalk
NOTE: Most coated surfaces, when exposed to the sun, will fade to some degree over a period of time. Five Hunter ¨E units is a noticeable, but
not usually objectionable, degree of color change. Colors may also darken or change hue rather than fade, particularly on exposure in polluted
environments. The Hunter ¨E units are intended to apply to color change in either direction in comparison with the original or unexposed color. It is
understood that fading or color change may not be in uniform if the surfaces are not equally exposed to the sun and elements.

For profiles: MP Panel, Shelterguard®, 5-Rib


For purposes of determining whether an exposed coated panel meets the standards set forth in above paragraph, all chalk, dirt and other film
deposits on the area of the panel to be tested for color must be removed by washing prior to evaluation.
To wash test area, use a pad of 28/24 mesh cheesecloth and distilled water with mild soap or detergent cleaner. Wet the cheesecloth thoroughly
with the solution and rub it, using moderate hand pressure, over an area of panel approximately 4" x 4". Care must be taken to avoid any
scratching, burnishing or other physical alteration of the coating surface. After washing as described above, flush off the test area with distilled
water and allow to air dry in a vertical position.
TM
4. Exhibit accumulations of red rust caused by acid rain on non-vertical installations of Enduracote painted panels for a period of ten (10) years
quantities that result in discoloration clearly visible in casual observation, except that this provision shall not apply to any accumulation of red rust
which occurs within one-half inch of any portion of the coated surface which is cut or penetrated at any time after application of the pretreatment and
paint system to the substrate.

TERMS AND CONDITIONS


Aluminum-Zinc Alloy Warranty

1. DURATION OF WARRANTY

20-year limited non-perforation


The paint coating of Fabral roofing and siding panels is guaranteed to perform in the manner described above for the lifetime of the structure for
crack, check, or peel, or 30 years for chalk and fade, or 10 years for red rust, from the date such panels are installed by Buyer, provided installation
occurs within six months from the date of application of coating by Seller's coating facility. In no event shall the guarantee extend beyond 30 years
and 6 months for chalk and fade, or 10 years and 6 months for red rust, from the date of application of coating by Seller's coating facility.

2. CONSTRUCTION CONDITIONS
NO EXPRESS WARRANTY AND NO IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A
For Bare Galvalume® Products
PARTICULAR PURPOSE shall apply:
(a) to roofing having a pitch of less than 2 ½:12 for Grandrib 3 ®, Alu-Tuff II, or Prime Rib panels, 1:12 for Mighti-Rib or Ultra-Rib panels.
(b) to roofing or siding panels applied without protection over lumber which has been treated with preservatives or fire resistant salts, regardless
whether such treatments are occasioned knowingly or without the knowledge of the buyer, the owner, or any other party.
This exclusion includes, but is not limited to, lumber which has been treated with ACQ (Alkaline Copper Quartenary), CA (Copper Azole), CBA
(Copper Boron Azole), pentachlorophenol, CCA (Chromated Copper Arsenate) salts, creosote, fluor chrome arsenate phenol, or any similar

Aluminum Product Guarantee


treatment for fire and rot resistance. Protection of lumber as provided for in this exclusion shall be defined as any barrier which prevents the
transfer of moisture and salts between the treated lumber and Fabral's roofing and siding material including 4 mil polyethylene, York Wrap or
equivalent durable vapor barrier or solid (non-porous) insulation. No other protective barrier shall be acceptable under this provision without the
express written approval of Fabral.
(c) failure to properly insulate the products between any dissimilar metals, contact with the ground, animal wastes, decaying materials or wet


absorptive materials.
(d) abnormally corrosive atmospheric conditions. This exclusion includes, but is not limited to, contamination from external sources such as
manufactured chemicals and salt spray, and internal contamination created by improper ventilation (design or operational defects) or improper
housekeeping, as defined by current Midwest Plan Service publications.
30-year corrosion guarantee
F-104

The Energy Star® Program


The Energy Star Program promotes highly reflective roof systems that reflect
solar energy. These roof systems allow buildings to stay cooler and, in turn,
use less electricity for air conditioning; less electricity means a reduction in
power generation and a reduction of pollutants discharged at power plants.
Fabral has attained Energy Star approval for many of its Enduracote™ sys-
tem colors. Ask for Technical Bulletin #724 titled “Energy Star Approval”, for
program details and a list of approved Enduracote™ colors.

Please contact your Fabral representative for more information about Fabral warranties and paint systems.
4
Steel Panel Profiles

Grandrib 3
29 Gauge steel, Plain, and Painted Galvanized
MP Panel

9"
37 3/4" FORMED WIDTH
36" COVERAGE
3/4"
3/4" 9"
37 3/4" FORMED WIDTH
36" COVERAGE Alu-Tuff
CORRECT SIDELAP
FOR ALU-TUFF,
GRANDRIB 3, AND
BUTYL SEALANT
MULTI-PURPOSE LOCATION (OPTIONAL 3/4"
STEEL PANELS. FIELD APPLIED)
9"

37 3/4" FORMED WIDTH


36" COVERAGE
PURLIN BEARING
LEG
SCREW PATTERNS
NAIL PATTERNS

Intermediate Roof Purlins and All Siding


All Supports
Eaves and Endlaps - Roof Purlins

Fastener Usage: 80 screws per square or 1 pound of nails per square

5V Crimp NAIL PATTERN


USE ON SOLID DECKING

ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS

SCREW PATTERN

1/2"
11 1/2"
26" FORMED WIDTH ROOFING - EAVES, RIDGES, AND ENDLAPS
24" COVERAGE

ROOFING - INTERMEDIATE SUPPORTS


SIDING - ALL SUPPORTS

NAIL PATTERN
1 1/4" Corrugated
ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS


SIDING - ALL SUPPORTS

SCREW PATTERN

ROOFING - EAVES, RIDGES, AND ENDLAPS


1/4" 1 1/4"
26" OVERALL
24" COVERAGE
ROOFING - INTERMEDIATE SUPPORTS
SIDING - ALL SUPPORTS

*Not all profiles are available in all areas. Please contact Fabral for availabilty. 5
Steel Panel Profiles
NAIL PATTERN
2 1/2" Corrugated
ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS

SIDING - ALL SUPPORTS

SCREW PATTERN

1/2" 2.667"
26" OVERALL ROOFING - EAVES, RIDGES, AND ENDLAPS
24" COVERAGE (SIDING)
21 1/2" COVERAGE (ROOFING)
ROOFING - INTERMEDIATE SUPPORTS
SIDING - ALL SUPPORTS

Proclad
XPRT 936
Sidelap Detail

SCREW PATTERNS

Intermediate Roof Purlins and All Siding

Eaves and Endlaps - Roof Purlins

38 3/8" FORMED WIDTH


36" COVERAGE
5/8"

*Not all profiles are available in all areas. Please contact Fabral for availabilty.

Other Steel Profiles Available

1 1/2” SSR 16" Coverage


24 Gauge Standing Seam Roofing 1 1/2"

Mighti-Rib® 39" Formed Width


36" Coverage

26 Gauge Roofing & Siding 4 3/8" 3 1/4" 4 3/8" 12"

1 3/16"

Climaguard™ 12" or 16" Coverage

26 Gauge Roofing 5 3/8"


7/8"

Factory Applied Sealant

1" Formed Width


424
36" Coverage

Grandbeam®
9"
9" 4"
7" 1 416
2" 13

26 Gauge Roofing & Siding


8 100° 8"

134°
134°

*The panels above are available at certain locations and have their own particular details, flashings, and accessories. Please contact Fabral for more information.
6
Aluminum Panel Profiles
Grandrib 3 
Alu-Tuff

ROOFING - EAVES, RIDGES, AND ENDLAPS


3/4"

9"
ROOFING - INTERMEDIATE SUPPORTS
3/4"
37 3/4" FORMED WIDTH
9"
37 3/4" FORMED WIDTH
SIDING - ALL SUPPORTS
36" COVERAGE 36" COVERAGE

Strongrib 
.0155 and .018 Aluminum, Plain, and Painted White

SCREW PATTERN

Correct Strongrib
BUTYL SEALANT
LOCATION (OPTIONAL INTERMEDIATE ROOF PURLINS AND ALL SIDING
Sidelap FIELD APPLIED)

EAVE AND ENDLAPS - ROOF PURLINS


PURLIN BEARING
LEG
3" 2 1/2"
4 9"
37 3/4" FORMED WIDTH
36" COVERAGE

Fabrib

ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS


SIDING - ALL SUPPORTS
9 2.667" 3 " FORMED WIDTH
51 16
16"
48" COVERAGE

AluTwin

ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS


SIDING - ALL SUPPORTS
7 8"
16" 5041" FORMED WIDTH
48" COVERAGE

2 1/2" Corrugated

ROOFING - EAVES, RIDGES, AND ENDLAPS

ROOFING - INTERMEDIATE SUPPORTS


SIDING - ALL SUPPORTS
1 2.667"
2"
51 41" OVERALL
48" COVERAGE (SIDING)
48" COVERAGE (ROOFING)

*Not all profiles are available in all areas. Please contact Fabral for availabilty. 7
Post Frame Estimating & Roof Types
Estimating Metal Roofing, Siding & Flashings

Panel lengths are to be determined by the truss top chord


or actual field measurements. Remember to add for over-
hangs at the eaves; subtract for a gap at the ridge. Sid-
ing should be kept up away from the ground with a skirt
board.

Number of Panels

The coverage of the panel being used will determine the


number of panels at a length (i.e.: 3’ coverage panel on a
30 ft. long building would require 10 panels on each side of
the ridge or 20 panels at the particular length.) Gambrel Roof

Horizontal Measurment to a Roof

Divide the building width in half, then multiply by the slope


factor (i.e.: 40’ wide building with 4/12 slope. 40 divided
by 2 equals 20’ times 1.054 equals 21’-1” in slope dimen-
sion.) Allow for 1/2” to 1” gap at peak and 1” to 2” eave
overhang.

Roof Pitch Slope Factor


3/12 1.031
4/12 1.054
5/12 1.083
6/12 1.120
8/12 1.202 Transition Roof
10/12 1.302
12/12 1.414

Flashing Conditions

Roof - Eave, Ridge, Gable, Sidewall, Endwall, Valley, Hip,


Transition, Gambrel, Soffits
Siding - Base Perimeter, Corners, Inside Corners, Man
Doors, Windows, Sliding Doors, Overhead Doors

Please contact Fabral’s Engineering Department


for all your estimating & specification needs.
Hip Roof

1-800-916-1413
1-800-322-1030 Fax
8
Post Frame Building Details

Ridge/Peak

Gable/Rake

Eave

Zee

Outside Corner
Base Guard

Sliding Door Track Covers


Drip Cap
Sidewall
Endwall Inside Corner

J-Channel/Doors/Windows

9
Standard Post Frame Flashing/Trims
All flashing is 10’ 6” in length & available in steel & aluminum, unless otherwise
noted. Please contact Fabral for specifics on the trim available in your area.

5 9/16"

11/16"

4 3/8"
8 7/8" 6 25/32"
AG1
1" Gable/Rake
1 1/16"
AJ6 Aluminum 10'
Jamb Trim 1 1/2" AR3 Steel 10' Standard
(for 2x wood) Ridge Cap 13/16" 14' in select colors
1 5/8"

4 5/8"

5 1/2" 5 1/2"

3"

RR1
Universal
AR3 w/ VersaVent RX-10 13/16"
Ridge/Hip
Flash Ridge Cap
Steel Only Grandrib 3 & Alutuff net free area = 10.66 sq. in. per lineal AE1
Customer to specify roof pitch feet of ridge (5.33 per side) Eave Flash

3"
6"

4"
4" 2 1/2"

24"
1/2"
CP1 1/2"
SunSky Ridge Monoslope CE1
Ridge Cap Ridge Denver Eave
Clear Only Steel Only Steel Only
Customer to specify roof pitch Customer to specify roof pitch

7/8"
7 7/8"
8"
1 3/4"

2 3/16"
1 1/4" 7/8" 7/8" 6 15/16"

7
AH4
8 7/8" 10'-6" Length
2 7/8" Face-Mount Track
Cover for Cannonball
Track with 1" Track 3/4"
1 5/16"
RJ9 PJFB Plank Matches

F-J Trim One Piece Door Trim Cannonball Trim


#646224

10
Standard Post Frame Flashing/Trims

7 1/4" 10 1/8"

6 1/4"
Soff Vent A
Notched Vented Aluminum Soffit
Net free area = 12.96 sq. in. per
lineal ft. of soffit
RV1
16"
Valley Flash
AGRN4 Customer to specify roof pitch
For Grandrib 3 4041" Length
Notched Gambrel Flash

AB3
1" Soffit Box
Net free area - 22.9 sq. in. per lineal ft. of soffit
(Vented available in white steel only)
9 3/16"
7"
5"

5 1/2"

AT1 1/2" RV2


Transition Flash W-Valley Flash 2 1/2"
Typical for 8/12 to 4/12 Steel Only 11 1/4"
(otherwise specify pitches) Customer to specify roof pitch
Steel Only

AB4
Soffit Box
Net free area = 22.9 sq. in. per lineal ft. of soffit
AB1 (Vented available in white steel only)
4"
Soffit Box
5 1/2"
5"
7 1/2"

ASW1
7 1/4" 2 1/2"
1/2"
Sidewall/Endwall 2 1/2"
Flash 11 1/4"

AEWN4
For Grandrib 3 40 1/4" Length
Notched Endwall Flash
7 1/2" AB2 7"
7 1/4" 5"
Soffit Box

6 1/4" AT1 1/2"


Transition Flash
7 1/4" 2 1/2" Typical for 8/12 to 4/12
Notched (otherwise specify pitches)
Steel Only

11
Standard Post Frame Flashing/Trims

4 3/8"
13/16"
AL2 = 3 1/2"
1 5/8"
AL3 = 5 1/2"
13/16"
1 1/16" AL4 = 7 1/4"
4 3/8" AL5 = 9 1/4"

3/4" 1 5/8"
1 1/2"
AC1
Corner

AZ2
Aluminum 10'
14'-6" in select AL2,3,4,5 Zee
colors Angle Flashing

7/8"
2 3/4"
1 5/8" 1"
7/8" 3 11/16"
1 1/16"
1 1/2"
3/4"

1 1/2"
1 5/8"

ABG1 AJ4
Base Guard Jamb Trim
AC2 Steel Only
Inside Corner (For 2x wood)

1 1/2"
9/16" 2 1/4"

1 1/2" AC3
AL6 13/16"
Corner
Angle Flashing
Available in Lancaster
service area only
1"
1 1/2"
AJ3
J-Channel
4 1/8" For Grandrib 3, Strongrib and all
2 5/16" AL7 other Agri panels
Angle Flashing

1 3/4" 1 3/8" 3 3/8"

1 5/8" 2 3/8"
AJ2
6 15/16" Jamb Trim 7 1/4"
2 5/16" Steel Only
AH5
10'-6" Length 1 1/16"
AH3
Face-Mount Track Cover
10'-6" Lengths
for Cannonball Track with 13/16"
Fits National 5100, 5103 1/2"
2" Track Plank 3/4"
1 5/16" and 5105 box rail. 3 5/8"
(Replaces STC-503) Matches National trim #5120
Matches Cannonball Trim (Replaces STC-504)
#646225
12
Standard Post Frame Flashing/Trims

4 1/4"
13/16" 1"
3 5/8"
1 5/8"
1 1/16" 7/8"
1 1/2"
6" 1/2"

AC4 3 5/8"
Corner AD1
AJ5
3/4" Steel Only Drip Cap
Jamb Trim
Steel Only
(For 4x wood)

7/8" 1 13/16"
1 3/4"

1 3/8" 1 1/2" 4"


6 15/16"
1 7/16"
AH4 2 3/8"
10'-6" Length AH6
AH2
Face-Mount Track
Cover for Cannonball 10'-6" Length 2 9/32" 10'-6" Length
Fits National 5110 & Fits National Top-Mount 4"
Track with 1" Track 3/4"
Plank Matches 1 5/16" 59 bo rail. Matches #5433 Rail with #5436
Cannonball Trim National trim #5122 Bracket or National
#646224 1/2" Top-Mount #5460 Rail with
attached bracket. Matches
National Trim #5455 1/2"

Post Frame Flashing Details


BOX GABLE
2" LONG FASTENER
@ 24" C/C MAX
FLASH AG-1

ROOFING SEALANT TAPE

SEALANT TAPE

1"x6" FASCIA
ROOF PURLIN
END RAFTER
SEALANT TAPE FASTENER
TOP & BOTTOM 24" C/C MAX
OF CLOSURE

FASTENER @ EVERY
MAIN RIB OR FLASH AB-1, AB-2,
12" C/C MAX. AB-3, OR AB-4
OUTSIDE CLOSURE
(OPTIONAL) 7 41" OR 11 41"

SIDING

13
Post Frame Flashing Details
ENDLAP
1. Apply 3/32” x 1/2” butyl endlap sealant on bottom pan-
el just below centerline of purlin (see endlap diagram for
location) on panel #1. ROOF PANEL

2. Apply sidelap sealant on panel #1 and connect to end- STEP #1 CONTINUOUS BEAD OF 3/32" x 1/2"
BUTYL SEALANT TAPE

lap sealant. DOWN SLOPE

3. Place panel #2 so it overlaps panel #1, 12” as shown. 2"


6 1/2"

Install screws per endlap fastening pattern. OVERLAPPING


FROM PURLIN EDGE
3 1/2"

4. Apply sidelap sealant on panel #2 to connect to side- 10" To Sealant


lap sealant of panel #1. STEP #2 FASTENERS @
ENDLAP PATTERN
ROOF PANEL
5. Place panel #3 over sidelap of #1 and #2.
6. Apply endlap sealant on panel #3. DOWN SLOPE

7. Apply sidelap sealant on panel #3 and connect with 2"


6 1/2"
PURLIN

endlap sealant. OVERLAPPING


FROM PURLIN EDGE
3 1/2"

8. Place panel #4 over endlap of panel #3. Install screws 12" Total Lap

per endlap pattern.


PR
9. Repeat sequence for entire roof. EV
AIL
ING
WI
ENDLAP TAPE ALIGN ND
WITH PURLIN EDGE

INSTALLATION SEQUENCE
FOR STRONGRIB, GRANDRIB 3,
5V CRIMP, ALU-TWIN 4
2 ENDLAP TAPE
SIDELAP TAPE THIS EDGE
THIS EDGE
5
5 SIDELAP TAPE 3
3 THIS EDGE
1 4
2
1

EAVE
OVERHANG
1" TO 2" WHEN INSTALLING 2 1/2" OR 1 1/4"
CORRUGATED ROOFING USE
SKIRT BOARD OF T) INSTALLATION SEQUENCE AS SHOWN
F EE
TREATED LUMBER OR (IN
FOUNDATION OF BLOCK "L"
12" TO 18" FROM ST
GROUND LEVEL
AR
T EN
D

ALLOWABLE PANEL LENGTHS (ft.) ALONG


THE SLOPE FOR 4" RAINFALL PER HOUR
Roof Slope
Panel
Name Minimum Slope 2 1/2:12 3:12 3 1/2:12 4:12 5:12 6:12
Alu-Tuff 2 1/2:12 58 61 64 67 73 78
Grandrib 3 2 1/2:12 58 61 64 67 73 78
Prime Rib 2 1/2:12 39 41 43 45 49 53
5V 2 1/2:12 43 45 47 49 54 58

2 1/2" Corrugated 2 1/2:12 28 29 31 32 35 38

1 1/4" Corrugated 2 1/2:12 16 16 17 18 20 21


Alutwin 2 1/2:12 37 39 41 43 46 50
Fabrib 2 1/2:12 32 34 36 38 41 44

Notes For Rain-Carrying Tables


1. All values based on a 1-hour duration storm of 4"/hr. intensity.
2. Values represent the point at which the panel ribs will flood.
3. Size and frequency of penetrations can greatly reduce the amount of water removed from a rooof.
4. All panel endlaps must be caulked.
5. When weather-tightness is crtical, use sealant tape in all sidelaps.

14
Post Frame Flashing Details
EAVE
FASTENER PER SEALANT TAPE
INSIDE CLOSURE STANDARD EAVE TOP & BOTTOM OF CLOSURE
PATTERN
458"
ROOF PANEL

3"
ROOF PURLIN
AE-1
FLASH CE-1
Eave Flash
SEALANT TAPE
TOP & BOTTOM 13
16"
OF CLOSURE
FAS TE NE R @ E VE R Y
R IB OR 12" C /C MAX.
OUTSIDE CLOSURE
(OPTIONAL)

SIDING ROOF TRUSS 3"

221"
POST CE-1
FASTENER Denver 1
TOP PLATE Eave 2"

BOX EAVE
AB-1
FASTENER PER ROOF PANEL Soffit Box
521"

STANDARD EAVE
PATTERN SEALANT TAPE
TOP & BOTTOM
221"

MODIFIED
OF CLOSURE 7 41"
AL-2

FASTENER @
24" C/C MAX. AB-2
Soffit Box
721"

INSIDE CLOSURE
5 21" EAVE PURLIN
7 41"
221"

OR
FASCIA BOARD
7 21" AB-3
Soffit Box
(Vented Available
521"

ROOF TRUSS in White steel only)


SEALANT TAPE
OUTSIDE
FASTENER 11 41"
221"

FLASH AB-1, AB-2, CLOSURE


AB-3, OR AB-4 (OPTIONAL)
AS REQUIRED 7 41" OR 11 41"
POST
AB-4
721"

SIDING TOP PLATE Soffit Box

11 41"
221"

PROVIDES 8" OR 12" OVERHANG WITH GRANDRIB 3, ALU-TUFF, OR STRONGRIB SIDING

15
Post Frame Flashing Details
VENTED EAVE
INSIDE CLOSURE WITH SEALANT FABRAL METAL ROOF PANEL
TAPE TOP & BOTTOM

FASTENER PER STANDARD


EAVE PATTERN

EAVE TRIM

FASCIA BOARD

TRUSS OR RAFTER
FASCIA L-TRIM,
AL-3, 4, OR 5

FABRAL ALUMINUM F/J TRIM


SOFFIT
FABRAL METAL 16" COVERAGE
SIDING PANEL

RIDGE/PEAK - NON VENTED

2" LONG FASTENER AR-3,


@ EVERY MAIN RIB RIDGE FLASHING
OR 12" C/C MAX.

ROOF PANEL

SEALANT TAPE
TOP & BOTTOM OUTSIDE CLOSURE
OF CLOSURE (ON HIP ROOFS, USE
1"X1"X19'-8" SEALER STRIP
& RR-1 FLAHING)
PURLIN
GAP AS REQUIRED

If closures are omitted, Fabral suggests using screen wire between


panels and ridge gap area to keep insects and birds out of attic area.
Closures and sealant are recommended for optimum weather resistance.

16
Post Frame Flashing Details
VENTED RIDGE
AR-3, RR-1
2" LONG FASTENER RIDGE FLASH
@ EVERY MAIN RIB

ROOF PANEL

VERSAVENT RX-10
GAP AS REQUIRED
PURLIN

VersaVent RX-10 Factory Applied To Ridge Cap


Vent Material and Ridge Cap Install As A Unit

ALTERNATE VENTED RIDGE


Fabral RR-1 Ridge Flash with CoraVent (shown). The RR-1 can be modified to fit many
other solid, plastic vents. Other solid, plastic vents (ie..Ridge Master,...) are available
from local lumberyards or dealers. The metal ridge flashing may have to be customized
to fit the particular vent. Mesh vents or fiber-type vents are not recommended because
a metal ridge can not be fastened securely. They are not rigid enough to give good
support or appearance to the metal flash. Coravent is available from Fabral.

OPTIONAL J-CHANNEL
FOR SUPPORT
RR-1 RIDGE FLASH
2 21" FASTENER @ EVERY
MAIN RIB OR 12" C/C MAX.
OUTSIDE CLOSURE
WITH BUTYL SEALANT
TOP & BOTTOM METAL ROOF
PANEL

2" TO 4" OR
AS REQUIRED
BY VENT
MANUFACTURER

PANEL FASTENER PER


STANDARD PATTERN

17
Post Frame Flashing Details
ALTERNATE VENTED RIDGE
AR-3, RR-1
2" LONG FASTENER RIDGE FLASH
@ EVERY MAIN RIB

ROOF PANEL

PROFILE VENT
GAP AS REQUIRED
PURLIN

Profile Vent is pre-notched and self adhesive. Fabral stocks


Profile Vent for Grandrib 3, Alu-Tuff, and 5v Crimp.

GABLE - STRONGRIB, GRANDRIB 3

FLASH AG-1 2" FASTENER @


24" C/C MAX.
ROOFING

OPTIONAL
SEALANT TAPE
TOP & BOTTOM
OF CLOSURE
SEALANT TAPE
PURLIN

FASTENER @
24" C/C MAX END RAFTER

OUTSIDE CLOSURE
(OPTIONAL)
SIDING

18
Post Frame Flashing Details
GABLE - FABRIB

FASTENER @
FLASH AG-4 24" C/C MAX

ROOFING

OPTIONAL
SEALANT TAPE
TOP & BOTTOM
OF CLOSURE

SEALANT TAPE PURLIN


FASTENER @
24" C/C MAX
END RAFTER
OUTSIDE CLOSURE
(OPTIONAL)
SIDING

GABLE - GRANDRIB 3 , STRONGRIB

FASTENER @
FLASH AC-1 OR AC-4
24" C/C MAX
ROOFING

OPTIONAL
SEALANT TAPE
TOP & BOTTOM
SEALANT TAPE PURLIN
OF CLOSURE

FASTENER @ END RAFTER


24" C/C MAX
OUTSIDE CLOSURE
(OPTIONAL)
SIDING

19
Post Frame Flashing Details
FLYING GABLE DETAIL

ROOF FELT
FASTENER

SEALER STRIP
(ASPHALT IMPREGNATED)
BUTYL SEALANT TOP AND
BOTTOM OF SEALER STRIP

CE1
FASCIA BOARD

20
Post Frame Flashing Details
ENDWALL

SIDING
INSIDE CLOSURE

FASTENER PER STANDARD


EAVE PATTERN
GIRT
2" FASTENER @ EVERY MAIN
RIB OR 12" C/C MAX. 1"

FLASH ASW-1

ROOF PANEL

SEALANT TAPE
TOP & BOTTOM
OF CLOSURE
OUTSIDE CLOSURE

PURLIN

ENDWALL - NOTCHED
SIDING

INSIDE CLOSURE
FASTENER PER STANDARD
EAVE PATTERN

GIRT
2" FASTENER @ EVERY MAIN
RIB OR 12" C/C MAX. 1"
NOTCHED FLASH
AEW-N4 OR AEW-N5

ROOF PANEL

SEALANT TAPE
TOP & BOTTOM
OUTSIDE CLOSURE OF CLOSURE

PURLIN
21
Post Frame Flashing Details
SIDEWALL
SEALER STRIP
WITH BUTYL SEALANT
TAPE SIDING

FASTENER PER STANDARD EAVE PATTERN


GIRT
SPACE AS REQUIRED
FLASH ASW-1
FIELD BEND
AS REQUIRED

SEALANT TAPE

2" FASTENER @ PURLIN


24" C/C MAX.

SLOPING RAFTER

VALLEY
BUYTL SEALANT
TOP & BOTTOM LARGER VALLEYS MAY BE
OF SEALER STRIP REQUIRED FOR LONG PANEL
RUNS OR HEAVY SNOW
CUT PANEL AS AREAS.
METAL ROOF PANEL NECESSARY
6" MINIMUM

SEALER STRIP,
1"x1"x19'-8"
SCREWS RV-2 BLOCK CLOSURE
EACH SIDE OF MAIN SHOWN FILLS RIB VOIDS
RIB (EAVE/ENDLAP ROOF FELT AND
PATTERN) ICE & WATER SHIELD
ROOF STRUCTURE
SOLID 2x'S OR
PLYWOOD

NOTE: VALLEY FLASH MUST HAVE SOLID SUPPORT.

FOR ADDITIONAL INFORMATION ON THE VALLEY


DETAIL REFER TO PAGES 42 AND 43 OF THIS BOOK.
22
Post Frame Flashing Details
GAMBREL

BUTYL SEALANT TAPE INSIDE CLOSURE


TOP & BOTTOM
OF CLOSURE FLASH AT-2 OR
AGR-N4 (GRANDRIB 3)
2" FASTENER @ EVERY MAIN RIB
OR 12" C/C MAX.
BUTYL SEALANT TAPE
TOP & BOTTOM
OF CLOSURE

ROOF PANEL
FASTENER PER
STANDARD EAVE PATTERN
OUTSIDE CLOSURE

3/12

15/12

NOTE: Specify both roof pitches for AT-2 flash. AGRN-4 for Grandrib 3
and AGRN-5 for Strongrib are for 3/12 to 15/12 Gambrel's

TRANSITION
BUTYL SEALANT TAPE
TOP & BOTTOM INSIDE CLOSURE
OF CLOSURE
FLASH AT-1

2" LONG FASTENER @ EVERY


MAIN RIB OR 12" C.C MAX.

BUTYL SEALANT TAPE


TOP & BOTTOM
OF CLOSURE
ROOF PANEL
FASTENER PER STANDARD
EAVE PATTERN
OUTSIDE CLOSURE

9/12

3/12

NOTE: Specify both roof pitches when ordering AT-1.


Standard is 9/12 to 3/12.
23
Post Frame Flashing Details
OUTSIDE CORNER
POST

SEALANT TAPE GIRT

SIDING
FLASH AC-3 *
2" FASTENER THROUGH PANEL
RIB @ 24" C/C MAX.

* Available in Lancaster service area only.

OUTSIDE CORNER

POST

SEALANT TAPE

WALL GIRT

SIDING
FLASH AC-1 OR AC-4 FASTENER @ 24" C/C MAX.

24
Post Frame Flashing Details
INSIDE CORNER
GIRT

FASTENER @
24" C/C MAX.

FLASH AC-2
POST

SEALANT TAPE

BASE GUARD
BARRIER BETWEEN METAL
AND ACQ TREATED LUMBER

SIDING PANEL

TREATED BASE INSIDE CLOSURE


PLANK (OPTIONAL)

FASTENER PER STANDARD


SIDING PATTERN

FLOOR 4" FLASH ABG-1


6" MIN.

G R ADE

25
Post Frame Flashing Details
DOOR JAMBS
DOOR JAMB
DOOR

FASTENER

GIRT

DOOR STOP

SIDING
FLASH PJFB

DOOR JAMB DOOR

FASTENER

GIRT DOOR STOP


FLASH AL-2, AL-3, AL-4,
AL-5, OR AL-7 DEPENDING ON
WIDTH OF JAMB

SEALANT
SIDING
FLASH AJ-3

FIELD BEND OR CUT THIS AREA


IF NECESSARY

DOOR
SEALANT TAPE

GIRT

1x3 DOOR STOP

SIDING 3
4"
FASTENER

FLASH AJ-2
26
Post Frame Flashing Details

OVERHEAD DOOR JAMBS

DOOR
DOOR JAMB

POST 1 x 3 GUIDE
FLASH AL-5 OR AL-7
GIRT
FASTENER

SEALANT TAPE
FLASH AJ-4
SIDING
FASTENER
DOOR OPENING

FIELD BEND OR CUT THIS AREA


IF NECESSARY
DOOR JAMB DOOR

1 x 3 GUIDE
GIRT

DOOR
DOOR JAMB

1 x 3 GUIDE SIDING
GIRT FASTENER
FLASH AL-3, AL-4,
AL-5 OR AL-7 FLASH PJFB
1 PIECE DOOR TRIM

SEALANT

SIDING
FASTENER FLASH AJ-3
DOOR
DOOR JAMB

POST
1 x 3 GUIDE
GIRT
FLASH AJ-2

3
4"
SIDING
DOOR OPENING
FASTENER

27
Post Frame Flashing Details
DOOR HEADER

SIDING
DOOR HEADER
FASTENER PER
SIDING PATTERN
FLASH AD-1

FLASH AL-2, AL-3, AL-4,


AL-5 OR AL-7
DOOR STOP
OVERHEAD
MAN DOOR
DOOR

SLIDING DOOR JAMB DETAIL

OPTIONAL AL-3 TRIM

POST

WALL GIRT AJ-4 JAMB TRIM

2 x 2 FILLER BLOCK

SIDING PANEL SLIDING DOOR


FLASH AL-6

SEALANT TAPE
SIDING

FLASH AJ-3
FASTENER

28
Post Frame Flashing Details
SLIDING DOOR HEADER DETAIL
SIDING

TRACK SUPPORT FLASH AH-2, AH-3 (SHOWN),


AH-4, OR AH-5.
REFER TO PAGE 11 FOR
2x6 TRACK BOARD CORRECT FLASHING FOR
PARTICULAR MANUFACTURER'S
DOOR TRACK BEING USED.

2x2 FILLER BLOCK

SIDING ON
SLIDING DOOR
DOOR GIRT
SIDING BEYOND OPENING

AD-1 OR BOTTOM RAIL


FROM DOOR MFR.
TREATED BASE PLANK

TRANSLUCENT PANEL

METAL SIDING OR
TRANSLUCENT PANEL
SEALANT TAPE
TOP & BOTTOM INSIDE CLOSURE
OF CLOSURE (OPTIONAL)
FASTENER PER
STANDARD PATTERN GIRT
FLASH AZ-2 USE TRANSLUCENT PANELS AS
SIDING PANELS TO ALLOW
LIGHT INTO THE BUILDING.
FASTENER @ EVERY MAIN DO NOT USE ON ROOFS.
RIB OR 12" C/C MAX.

SEALANT TAPE
OUTSIDE CLOSURE
TOP & BOTTOM
(OPTIONAL)
OF CLOSURE
TRANSLUCENT SIDING OR
METAL SIDING

29
Post Frame Flashing Details
WINDOW DETAILS

SILL

WINDOW UNIT
1x6 BEVELED 1"

FLASH AJ-3

FASTENER PER
2x4 STANDARD PATTERN
SIDING

HEAD
SEALANT TAPE
TOP & BOTTOM
2x4 OF CLOSURE

FASTENER PER
STANDARD PATTERN
AD1 DRIP CAP

INSIDE CLOSURE
WINDOW UNIT (OPTIONAL)

JAMB

WINDOW UNIT
FLASH AJ-3

FASTENER

2x4
OPTIONAL
SEALANT TAPE
GIRT
SIDING

30
Residential Building Details
RIDGE/PEAK
CHIMNEY VALLEY
ENDWALL PIPE PENETRATION
TRANSITION

SIDEWALL
SKYLIGHT
EAVE
GABLE/RAKE

HIP

Basics for Residential Installation

1. Determine the thickness and type of substrate to be used to support the metal roofing.
Solid decking is highly recommended for all resdiential applications (i.e.,
plywood, OSB).

2. Refer to the Load-Span tables to select the proper fastener and spacing to meet loads on your
structure.
Nails are NOT recommended for residential applications.

3. Consult local building codes and restrictions to determine acceptable methods of construction
for residential applications in your area.

4. Solid decking with 30# felt or Pro Master® underlayment for residential applications is recom-
mended. Ice & water shield or similar self-adhesive membrane is recommended at all valleys,
dormers, chimneys, transitions, skylights and other critical areas.

5. When re-roofing with metal panels over an existing shingle roof, 2x4 purlins or 1x4 furring
strips run parallel with the ridge of the roof and must be securely fastened into the roof rafters
or trusses.

6. Request Fabral’s technical bulletins # 720 and # 721 for more details on residential roofing.

31
Residential Load Table
R
GRANDRIB 3
R

Load-S pan Tables For 29 G auge G randrib 3 & Alu-Tuff


Allowable Wind Uplift Loads (psf)

S pacing of Fastener R ows


S ubstrate F astener 9" 12" 15" 18" 21" 24"
3/4" P lywood # 14 Woodtite 275.6 206.7 165.4 137.8 118.1 103.4
5/8" P lywood # 14 Woodtite 160 120 96 80 68.6 60
1/2" P lywood # 14 Woodtite 135.9 101.9 81.5 67.9 58.2 51.0
23/32" OS B # 14 Woodtite 115.9 86.9 69.5 57.9 49.7 43.5
19/32" OS B # 14 Woodtite 100.7 75.5 60.4 50.3 43.1 37.8
7/16" OS B # 14 Woodtite 61.5 46.1 36.9 30.7 26.3 23.1
S olid 2x S PF # 14 Woodtite 293 220.0 176.0 146.7 125.7 110.0
S olid 1x P ine # 14 Woodtite 207.1 155.3 124.2 103.5 88.7 77.7
S olid 2x S PF # 9 WoodFast 218.7 164.0 131.2 109.3 93.7 82.0
S olid 1x P ine # 9 WoodFast 168.4 126.3 101.0 84.2 72.2 63.2
S crews per S quare 190 150 120 100 90 80

T he Above L oads and fas tener quantities are bas ed on the s tandard fas tening
s chedule s hown on page 4 of this book, with the fas tener having an embedment
depth of 1" into the s olid wood and penetrating the plywood or OS B . C ontact
F AB R AL for additional des ign information on our products .

Other Residential Profiles

1 1/2” SSR 16" Coverage

24 Gauge Standing Seam Roofing 1 1/2"

Climaguard™
26 Gauge Roofing
12" or 16" Coverage
5 3/8"
7/8"

Factory Applied Sealant

5V Crimp 26" Formed Width


24" Coverage

26 Gauge Roofing 1/2" 12"

1" 1" 1/2"

The above Fabral profiles have their own detail manuals, flashings, and accessories. Please contact Fabral for additional information.
32
Standard Residential Flashings/Trim
All flashing is 10’ 6” in length & available in steel & aluminum, unless otherwise
noted. Please contact Fabral for specifics on the trim available in your area.

4 1/4" 3"
7/8"

3 1/4" 2 1/2"
1 1/16"

Soff Vent A
Vented Aluminum Soffit 1/2"
Net free area = 12.96 sq. in. per RG1 CE1
lineal ft. of soffit
1/2"
Residential Denver Eave
16" Gable Steel Only
Customer to specify roof pitch

6 25/32" 10 1/8"
6"

4"

AR3
Ridge Cap RV1
Valley Flash
1/2" Customer to specify roof pitch
CP1
Monoslope 1"

Ridge 9 3/16"
Steel Only
Customer to specify roof pitch 7"
5"

RV2
W-Valley Flash
Steel Only AT1
Customer to specify roof pitch
1/2"
Transition Flash
Typical for 8/12 to 4/12
(otherwise specify pitches)
5 1/2" 5 1/2" 4 1/8" Steel Only

9/16"
RR1 4 1/8" 7" 5"
Universal AG4
Ridge/Hip Gable
Flash
Steel Only
Customer to specify roof pitch
1/2"
AT2
9/16" Gambrel Flash
Typical for 3/12 to 15/12
(otherwise specify pitches)

AB3 2 1/2"
4" Soffit Box 7/8"
Net free area - 22.9 sq. in. per lineal ft. of soffit
(Vented available in white steel only)

3 1/4" 1 1/16"
5"
5 1/2"

ASW1
1/2" 2 1/2" WG1
Sidewall/Endwall 11 1/4" 1/2"
Flash Residential
Gable
33
Residential Flashings Detail
All residential flashings are formed for a 4/12 pitch unless otherwise requested by
the customer.

RESIDENTIAL RIDGE/HIP

RIDGE CAP
2" LONG FASTENER RR-1 or AR-3
@ EVERY MAIN RIB
OR 12" C/C MAX.
ROOF PANEL

ROOF STRUCTURE

SEALANT TAPE OUTSIDE CLOSURE


TOP & BOTTOM OF (ON HIP ROOFS USE
CLOSURE OR SEALER 1" x 1" x 19'-8"
STRIP SEALER STRIP AND
RR-1 FLASHING)

RESIDENTIAL VENTED RIDGE

2" LONG FASTENER RIDGE CAP


@ EVERY MAIN RIB RR-1 or AR-3
OR 12" C/C MAX.
ROOF PANEL

VERSAVENT RX-10 ROOF STRUCTURE


OR
PROFILEVENT

34
Residential Flashings Detail
RESIDENTIAL VENTED EAVE

INSIDE CLOSURE WITH SEALANT FABRAL METAL ROOF PANEL


TAPE TOP & BOTTOM

EAVE TRIM

FASCIA BOARD

TRUSS OR RAFTER

FASCIA L-TRIM

FABRAL ALUMINUM F/J TRIM


SOFFIT
FABRAL METAL 16" COVERAGE
SIDING PANEL

RESIDENTIAL EAVE

FASTENER PER STANDARD EAVE PATTERN


BUTYL TAPE ROOF PANEL
TOP & BOTTOM
OF CLOSURE

CE-1

ROOF STRUCTURE
FASTENER INSIDE
@ 24" C/C MAX. CLOSURE

35
Residential Flashings Detail
RESIDENTIAL GABLE

BUTYL TAPE
RG-1, WG-1
OR AG-4
ROOF PANEL

SCREW
FASTENER
@ 24" C/C MAX.
CUT PANEL AS
ROOF STRUCTURE
NECESSARY
START GABLE

FINISHING
END GABLE

RESIDENTIAL ENDWALL

SIDING

2" FASTENER @ EVERY


MAIN RIB
FLASH ASW-1
ROOF PANEL

BUTYL TAPE
TOP & BOTTOM
OUTSIDE CLOSURE OF CLOSURE

36
Residential Flashings Detail
RESIDENTIALGAMBREL

BUTYL SEALANT TAPE


TOP & BOTTOM
OF CLOSURE
INSIDE CLOSURE FLASH AT-2 OR
AGR-N4 (GRANDRIB 3)

2" FASTENER@ EVERY MAIN


RIB OR 12" C/C MAX.

BUTYL SEALANT TAPE


TOP & BOTTOM
OF CLOSURE
FASTENER PER STANDARD ROOF PANEL
EAVE PATTERN

OUTSIDE CLOSURE

RESIDENTIAL SIDEWALL

SIDING

FLASH ASW-1
FASTENER 2" FASTENER @ 12" C/C

BUTYL SEALANT
ROOF PANEL

ROOF SHEATHING
ROOFING FELT AND
ICE AND WATER SHIELD
FOR ADDED WEATHER TIGHTNESS

37
Residential Flashings Detail
RESIDENTIAL TRANSITION

ROOF PANEL
FASTENER PER EAVE
FASTENING PATTERN INSIDE CLOSURE

30# FELT AND ICE AND WATER SHIELD


FOR ADDED WEATHERTIGHTNESS
FLASH AT-1

BUTYL TAPE
OUTSIDE CLOSURE TOP & BOTTOM
OF CLOSURE
FASTENER @ EVERY MAIN
RIB OR 12" C/C MAX.

RESIDENTIAL PIPE BOOTS


(OPTIONAL) SILICONE
SEALANT AROUND
CUT OF BOOT

VENTILATION
PIPE
ROOF PANEL

PIPE BOOT

BUTYL SEALANT TAPE


UNDER BASE OF
PIPE BOOT

SCREWS SPACED 2" TO 3"


PLYWOOD DECK
MAX AROUND BASE TO
SECURE
PIPE BOOT SIZES
#3 41" TO 5" PIPE DIA.
#5 4 41" TO 7 21" DIA.
#8 7" TO 13" DIA.

38
Residential Flashings Detail
SKYLIGHT & CHMINEY DETAILS

For optimum weatherthightness, use


NOTE: SEE CROSS ice and water shield or similar
SECTIONS A-A, B-B, C-C around penetrations.

CRICKET FIELD FORMING

ALTERNATIVE CRICKET DETAIL FASTEN TOP OF CRICKET TO BASE


TOP OF CRICKET FIELD USING #14 MP. CAULK ALL JOINTS
I I/2" SSR WHC1 "HIP FORMED FROM FLAT SHEET AND SEAMS WITH ONE-PART
CLOSURE" POLYURETHANE SEALANT.
USE TO CREATE
BASE/FRAME OF
CRICKET

CUT TRIANGULAR CRICKET TOP


FOLD UP WIDE END OF TRIANGLE.
SLIT CENTER OF FOLD AND BEND FABRICATE SMALL CAP
SLIGHTLY DOWN THE CENTER. TO COVER AREA WHICH
WAS SLIT

39
Residential Flashings Detail
SKYLIGHT DETAILS
SEALANT
FLASHING ASW-1 - FIELD MODIFY AS REQUIRED
FASTENER @ 6" C/C
SEALANT
ICE AND WATER SHIELD AND
30# FELT OR TITANIUM UDL UNDERLAYMENT

SASH

FRAME
CUSTOM DIVERTER FLASH
CONTINUE SUCH THAT
THE DIVERTER AND
ROOF SHEATHING VALLEY FLASH OVERLAP
SCREEN
1/2" PLYWOOD
1/2" RIGID INSULATION
JAMB ROOF FRAMING
SEALANT 6" MIN ROOF PANEL
SIDEWALL DETAIL
SECTION A-A INSIDE CLOSURE
ICE AND WATER SHIELD AND
30# FELT OR TITANIUM UDL
UNDERLAYMENT
SEALANT TAPE
SASH TOP & BOTTOM
OF CLOSURE

FRAME ROOF SHEATHING FASTENER @ 6" C/C MAX.


BATT INSULATION
DRYWALL
PLYWOOD
HEADER

CRICKET FIELD FORMING


SECTION B-B

SEALANT TAPE
BETWEEN FLASH
AND ROOF PANEL
FASTENER @ 6" C/C
ROOF PANEL
SEALANT
FLASHING -REVERSE
AL FLASHING
CONTINUOUS SIKAFLEX
CAULK @ PERIMETER ICE AND WATER
SHIELD AND 30# FELT
OR TITANIUM UDL ASW-1 FLASHING
UNDERLAYMENT FIELD MODIFIED SASH
TO FIT
2" FASTENER @ EVERY
SIDEWALL DETAIL MAIN RIB OR 12" C/C MAX.
ALTERNATE SECTION A-A BUTYL TAPE
TOP & BOTTOM
SEALANT
OF CLOSURE
FRAME
ROOF PANEL
ICE AND WATER SHIELD AND
30# FELT OR TITANIUM UDL
UNDERLAYMENT

ROOF SHEATHING
OUTSIDE CLOSURE HEADER
FASTENER
ENDWALL DETAIL
SECTION C-C
40
Residential Flashings Detail
CHIMNEY DETAILS
SAW CUT REGLET
1/2" - 1" DEEP
BLOW OUT DUST & FILL WITH SIKAFLEX
SEALANT. SET FLASH & FASTEN WITH
COMPATIBLE MASONRY ANCHOR
AL FLASHING
FLASHING ASW-1 - FIELD MODIFY
AS REQUIRED ICE AND WATER SHIELD AND
FASTENER @ 6" C/C 30# FELT OR TITANIUM UDL
SEALANT UNDERLAYMENT
SEALANT
ROOF PANEL

ALTERNATE FLASHING SAW CUT REGLET


1/2" - 1" DEEP
BLOW OUT DUST & FILL WITH SIKAFLEX
ROOF SHEATING SEALANT. SET FLASH & FASTEN WITH
SIDEWALL DETAIL COMPATIBLE MASONRY ANCHOR
FLASHING -REVERSE
AL FLASHING
AL FLASHING
CONTINUOUS SIKAFLEX
CAULK @ PERIMETER
FASTENER @ 6" C/C
SEALANT ROOF PANEL

ICE AND WATER SHIELD AND


30# FELT OR TITANIUM UDL
ALTERNATE FLASHING UNDERLAYMENT
ROOF SHEATING
SEALANT TAPE
BETWEEN FLASH
CUSTOM DIVERTER FLASH
AND ROOF PANEL
1/2" PLYWOOD CONTINUE SUCH THAT SIDEWALL DETAIL
1/2" RIGID INSULATION THE DIVERTER AND
VALLEY FLASH OVERLAP

ROOF PANEL
INSIDE CLOSURE
6" MIN

SEALANT TAPE
TOP & BOTTOM
OF CLOSURE
ROOF SHEATING FASTENER @
BATT INSULATION 6" C/C MAX.
ICE AND WATER SHIELD AND
SAW CUT REGLET
30# FELT OR TITANIUM UDL
1/2" - 1" DEEP
UNDERLAYMENT
BLOW OUT DUST & FILL WITH SIKAFLEX
SEALANT. SET FLASH & FASTEN WITH SAW CUT REGLET
COMPATIBLE MASONRY ANCHOR 1/2" - 1" DEEP
CRICKET FIELD FORMING BLOW OUT DUST & FILL WITH SIKAFLEX
SEALANT. SET FLASH & FASTEN WITH
COMPATIBLE MASONRY ANCHOR

ASW-1 FLASHING
FIELD MODIFIED
TO FIT
2" FAS TE NE R @ E VE R Y
MAIN R IB OR 12" C /C MAX.

BUTYL TAPE AL FLASHING


TOP & BOTTOM
OF CLOSURE
ROOF PANEL
SEALANT
ICE AND WATER SHIELD AND
30# FELT OR TITANIUM UDL
UNDERLAYMENT

ROOF SHEATHING
ALTERNATE FLASHING
OUTSIDE COLSURE

FASTENER
ENDWALL DETAIL
41
Residential Flashings Detail
DORMER DETAILS

DORMER DETAIL- SIDE VIEW

PLAN VIEW OF SIDE OF DORMER

SEALER STRIP,
1" x 1" x 19'-8"
BLOCK CLOSURE
FILLS RIB VOIDS
BUTYL SEALANT
VALLEY FLASHING
TOP & BOTTOM
OF SEALER STRIP 6" MIN

SCREWS ROOF FELT AND


EACH SIDE OF MAIN ICE & WATER SHIELD
RIB (EAVE/ENDLAP RV-1 OR
PATTERN) AND ONE RV-2 (SHOWN)
SOLID DECK
ADDITIONAL, CENTRALLY
LOCATED IN THE PAN OF
THE PANEL SECTION B-B

SOLID SUPPORT IS REQUIRED UNDER THE VALLEY. EPDM LINING IS


RECOMMENDED UNDER LAPPED PANELS AND VALLEY FLASHING.
LINING MUST CONTINUE DOWN TO EAVE LINE.
42
Residential Flashings Detail
DORMER DETAILS

PLAN VIEW OF TOP OF DORMER

SEALER STRIP
BUTYL SEALANT RIDGE CAP; EXTEND TO VALLEY
TOP & BOTTOM PEAK; CUT, FOLD, TRIM, SEAL,
SCREW
OF SEALER STRIP AND FASTEN TO VALLEY PEAK

6" MIN

SCREWS
EACH SIDE OF MAIN
RIB (EAVE/ENDLAP
PATTERN) AND ONE VALLEY LINING
ADDITIONAL, CENTRALLY CLOSURE; CAULK PERIMETER
LOCATED IN THE PAN OF VALLEY FLASHING TRIM AND SEAL AT VALLEY PEAK
THE PANEL RV-2 SHOWN
METAL FLASHING TO COVER
SOLID DECK
LAP AT VALLEY PEAKS (CAULK)

SECTION A-A
43
Accessories

Pipe Boots
Flat 29 gage painted and plain galvanized Pipe Flashing Item Pipe Size Translucent Panels
16" x10').
sheets available in full width (40 13 Gray EPDM No. Min Ma Fiberglass
Flat sheets are made in grade 33 steel for Base Diameter Grandrib 3 - White, Green - 8', 10', 12'
7 34" Strongrib - White - 10', 12'
4" 5"
1
better hemming, forming, and flexibility for 3
Fabrib - Green -12'
field forming. 10 34" 5 4 4"
1
7 21"
(availability by location - check with
16 21" 8 7" 13"
sale service rep.)
Used for field forming crickets around SunSky Polycarbonate
chimneys, skylights, and penetrations. Grandrib 3 & Alutuff
Also used for field forming special flashing Clear & White - 8',10',12'
(Available Everywhere)
as necessary.
Sealant Tape
16" x 4" x 40'
3 1

32 "x 2" x40'


3 1
Closures

Inside (Eave)

Outside (Ridge)
PROFILE VENT
Grandrib 3, Strongrib, 141" Corrugated,
GRANDRIB 3 & ALU-TUFF (SHOWN), 221" Corrugated, 5V Crimp, and Fabrib
5V CRIMP Asphalt Impregnated Sealer Strip
1"x1"x19'-6.8" long available by location - check with
Grandrib 3 net free area = 10.66 sq. in. per sales service rep.
lineal ft. of ridge (5.33 per side) USE AT VALLEYS AND HIPS

Screws

#9-16 WoodFast
4"
hex head, EPDM/metal washer,
1

Oxyseal Long-Life Coating


Available in 1", 1 21", 2", 2 21" and 3"
- Plain or Painted
#9-16 WoodFast
#10-16 Ultimate WoodTite 300 Series Stainless Steel
5
16" cast Zinc hex head Available in 1", 1 21", and 2"
Available in 1", 1 12", 2" , 212" and 3"
4" hex head, EPDM/metal washer
1
USE WITH GALVALUME PANELS
USE WITH ALUMINUM PANELS

Nails
#14-10 WoodTite
Fabroseal with washer for
4"
1

roofing -2", 221" & 3" 5


16" hex head, EPDM/metal washer,
Regular neoprene washer for siding Oxyseal Long-Life coating. Plain or Painted
1", 112", 2" USE AS STITCH SCREW & TO
-121", 134", 2", & 221"
FASTEN METAL TO PLYWOOD OR OSB
Plain Zinc coated and Painted
44
Fabral Plants Nationwide

St. Joseph, MN

Light Gauge/Post Frame Plants


Cedar City, UT (800) 432-2725 Mooresburg, TN (800) 500-0059

Columbia, SC (877) 972-6662 Mt. Vernon, OH (800) 688-3550

Gridley, IL (800) 451-3 974 St. Joseph, MN (800) 873-3440

Hopkinsville, KY (888) 317-6662 Salem, OR (800) 477-8028

Idabel, OK (800) 926-8509 Spokane, WA (800) 456-9124

Lancaster, PA (800) 477-2741 Tifton, GA (800) 749-8144

Marshfield, WI (800) 528-0878

Corporate Office
3449 Hempland Rd.
MEMBER
Lancaster, PA 17601
Rural Builder Magazine
Gold Key Recipient
(800) 477-2741
Fax (800) 283-4289
All 16 Consecutive Years

www.fabral.com 11/07 APC 10k 98-32-007