Chilled beam - iQ Star Wega-4

Sustainable chilled beam system for flexible utilization

Air Climate Systems


Introduction of chilled beam
Requirements of the market
IQ Star range and new WEGA beam
Wega beam – Variable airflow
Static pressure control
Controls for WEGA, STRA-14
Documentation
References

Air Climate Systems


System with constant static pressure control

• The system is pressure-dependent:


− The airflow through the nozzles depends on the static pressure.
− If the pressure changes, the airflow is modified.
• When the red chilled beam will increase or decrease its airflow, the airflow in the
other beams must remain the same.
• The static pressure must be constant along all the ductwork.

Air Climate Systems


System with constant static pressure , airflow vs (pressure, nozzles)

Pressure in Airflow
Beam
the duct Mode Nozzle
length (l/s)
work

Energy
90 2,4 aving 1 8,3
mode

Normal
90 2,4 4 34
mode

Boost
90 2,4 6 59,4
mode

Air Climate Systems


Air side design – EMPA/D damper to control static pressure

1 damper per zone:


• # facade, North - South
• internal our external zone
• Offices area or meeting rooms area

Air Climate Systems


Air side design – Exhaust ductwork

Air Climate Systems


Air side design – VAV Ductwork

• The airflow is variable into the ductwork.

• The ductwork is designed by zone of same static pressure.

• Same duct size per zone

Air Climate Systems


AHU, constant pressure control

• The AHU is controlled by a


pressure sensor to keep P
constant pressure.
• There are frequency
converters for fans
Air Climate Systems
Introduction of chilled beam
Requirements of the market
IQ Star range and new WEGA beam
Wega beam – Variable airflow
Static pressure control
Controls for WEGA, STRA-14
Documentation
References

Air Climate Systems


Room controller STRA-14
• 3 positions controller (Energy Saving Mode, Normal Mode, Boost Mode)
• Communication via RS485 (Modbus or EXOline)
• Easy installation thanks to separate basic plate for cable connections.
• 4 separate operation positions
• On/Off or 0...10 V control
• Input for occupancy detector, window contact, CO2 sensor, condensation detector
• 6 different pre-programmed control sequences relevant for chilled beam applications.

Air Climate Systems


FWG Control - STRA 14, sequence with occupancy sensor and CO2
sensor when Stella or Wega

Occupancy sensor or button

Air Climate Systems