Sizing Calculations for Separators with liquid leg U tube seals
Input Data Value Unit
Gas Density 0.06 lb/ft3 Mud Density 14 ppg Gas Viscosity 0.01 cP Maximum Acceptable Entrained Droplet Size 600 Microns Nominal Diameter of Vent Line 8 inches Equivalent Length of Vent Line** 150 Feet Mud Gas Separator Temperature 90 °F Separator Internal Diameter 4 Feet Liquid Leg Height 12 Feet Ambient Compressibility 1 Ambient Pressure 14.7 psia Ambient Temperature 60 °F
**Including extra length for bends & fittings - See table to the right of this page.
Separator Gas Capacity based on Liquid Leg Fluid Column
Calculation based on Weymouth Equation Allowable Pressure Drop over Vent Line (DPmax) 8.7 psig Maximum Pressure in Separator (Ps) 23.4 psig Maximum Allowable Volumetric Flowrate (Q1) = 20.3 MMscf/day
Separator Capacity 15.63 MMscf/day
Liquid Flowrate 800 GPM
Fluid Height in Separator 4.0 Ft Separator Liquid Volume 9.0 BBL Retention Time 0.47 minutes