Вы находитесь на странице: 1из 2

Table 3.2.

1
e Resistance Rating Requirements for Separating Walls and Floor/Ceiling Assemblies betwe
(See Section 3.1.8 for exceptions)

A1 A2 A3 A4 A5 B1 B2 C1 C2 C3 C4 D1 D2 E1 E2 E3 E4 E5 F1 F2 F3 F4 F5
A1 NA §
A2 NA 1.5
A3 NA 2 1.5
A4 NA 2 2 1
A5 NA 2 2 2 2
B1 NA 2 2 2 2 2 § NA = Not Applicable
B2 NA 2 2 2 2 2 2 ‡ NP = Not Permitted
C1 NA 3 3 2 3 3 3 2
C2 NA 2 2 2 2 2 2 2 2
C3 NA 3 3 2 3 3 3 2 2 2
C4 NA NP ‡ NP NP NP NP NP NP NP NP 2
D1 NA 3 3 2 3 3 3 3 3 3 3 2
D2 NA NP NP NP NP NP NP NP NP NP NP 2 2
E1 NA 2 2 2 2 2 2 3 2 3 3 3 NP 3
E2 NA 2 2 2 2 2 2 3 2 3 3 3 NP 2 2
E3 NA 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3
E4 NA 2 2 2 2 2 2 3 2 3 3 3 3 2 2 3 2
E5 NA 2 2 2 2 2 2 3 2 3 3 3 NP 2 2 3 2 2
F1 NA 2 2 2 2 2 2 3 2 3 3 3 3 2 2 3 2 2 2
F2 NA 2 2 2 2 2 2 3 2 3 NA 3 3 2 2 3 2 2 2 2
F3 NA 2 2 2 2 2 2 3 2 3 NA 3 3 2 2 3 2 2 2 2 2
F4 NA 2 2 2 2 2 2 3 3 3 NA 3 NP NP NP NP 3 NP 2 3 3 3
F5 NA 2 2 2 2 2 2 3 2 3 NA 3 3 NP NP NP 2 NP 4 2 2 2 3
G1 NA 2 2 2 2 2 2 3 2 3 3 3 NP NP NP NP 2 NP 2 2 2 2 2
G2 NA 3 3 2 3 3 3 3 3 3 3 3 NP NP NP NP 3 NP 3 3 3 3 3
H1 NA 2 2 2 2 2 2 3 2 3 3 3 3 2 2 3 2 2 2 2 2 2 2
H2 NA 3 3 3 3 3 3 4 3 4 3 4 3 3 3 3 3 3 2 3 3 3 2
J1 NA NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP
J2 NA NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP
K1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
K2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
een M ixed Occupancies (hours

G1 G2 H1 H2 J1 J2 K1 K2

2
2 2
2 2 2
2 2 2 2
4 4 4 4 NP
4 4 4 4 NP NP
1 2 1 2 4 4 1
1 2 1 2 4 4 1 1

Вам также может понравиться