Вы находитесь на странице: 1из 90

Hydraulic Screw-in Cartridge Valves (SiCV)

Circuit maker solutions


Screw-in cartridge valve packages for applications
up to 350 bar (5000 psi) and 300 L/min (80 USgpm)
Circuit maker solutions
Circuit maker solutions..................................................... K-4 RGV-30 - Regenerative valve.......................................... K-54

FC-1 - Flow control.......................................................... K-10 RGV-90 - Regenerative valve.......................................... K-56

FC-2 - Flow control.......................................................... K-12 RLV-30 - Regenerative valve........................................... K-58

FC-3 - Flow control.......................................................... K-14 RLV-90 - Regenerative valve........................................... K-60

FC-4 - Flow control.......................................................... K-16 SCR-1 - Cross port relief................................................. K-62

FRC-1 - Flow control........................................................ K-18 1UL255 - Unloading valve .............................................. K-64

FRC-2 - Flow control........................................................ K-20 Special housings - bolt on solutions.............................. K67

FRC-3 - Flow control........................................................ K-22 Dual cross-over relief package for


H&T series motors........................................................... K-68
FRC-4 - Flow control........................................................ K-24
Dual cross-over relief package
PCC1-12 - Pump control.................................................. K-26 for 2000 series disc valve motors................................... K69

PCC1-16 - Pump control.................................................. K-28 1CESHHT35/1CEESHHT35 - Motor


mounted valves............................................................... K-70
PCC2-12 - Pump control.................................................. K-30
1CESH2K95/1CEESH2K95 - Motor
PCC2-16 - Pump control.................................................. K-32 mounted valves............................................................... K-72
PFRR-8 - Flow control..................................................... K-34 1CLLROMP150 - Motor mounted relief......................... K-74
PFRR-10 - Flow control.................................................... K-36 1CEOMP35/1CEEOMP35 - Motor mounted valves....... K-78
PFRR-16 - Flow control................................................... K-38 1CEHT35/1CEEHT35 - Motor mounted valves.............. K-79
SRV-8 - Unloading/Relief valve...................................... K-40 1CE2K95/1CEE2K95 - Motor mounted valves.............. K-81
SRV-10 - Unloading/Relief valve.................................... K-42 1CEOMP35/1CEEOMP35 - Motor mounted valves ..... K-83
SRV-12 - Solenoid vented relief valve........................... K-44 1CESHOMP35/1CEESHOMP35 -
Motor mounted valves ................................................... K-86
SRV-16 - Solenoid vented relief valve........................... K-46
1CESHOMS95/1CEESHOMS95 -
SRV-20 - Solenoid vented relief valve........................... K-48 Motor mounted valves.................................................... K-88
CRV-10 - Relief valve........................................................ K-50

CRV-16 - Relief valve....................................................... K-52

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-3
Circuit maker solutions
Valve locator

Functional symbol Flow Typical


Reg. Model Cavity rating pressure Page

Flow control, full range adjustable L/min (USgpm) bar (psi)

FC-1 Inline 36 (9) 210 (3000) K-10


FC-2 Inline 57 (15) 210 (3000) K-12
FC-3 Inline 114 (30) 210 (3000) K-14
FC-4 Inline 190 (50) 210 (3000) K-16

In

Reg.
Flow Typical
Model Cavity rating pressure Page

Flow control, full range adjustable L/min (USgpm) bar (psi)

FRC-1 Inline 36 (9) 210 (3000) K-18


FRC-2 Inline 57 (15) 210 (3000) K-20
FRC-3 Inline 114 (30) 210 (3000) K-22
FRC-4 Inline 190 (50) 210 (3000) K-24

In

S2 T2

Flow Typical
Model Cavity rating pressure Page

Pump control, single pump circulation L/min (USgpm) bar (psi)


G T1
PCC1-12 Inline 114 (30) 210 (3000) K-26
PCC1-16 Inline 228 (60) 210 (3000) K-28

P T

S2 T2

K Flow Typical
Model Cavity rating pressure Page
G T1 Pump control, single pump circulation L/min (USgpm) bar (psi)
PCC2-12 Inline 114 (30) 5-210 (3000) K-30
PCC2-16 Inline 228 (60) 10-210 (3000) K-32

P T

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-4 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Circuit maker solutions
Valve locator

Functional symbol
Flow Typical
G
Model Cavity rating pressure Page

Flow control, relief on priority flow L/min (USgpm) bar (psi)


PFRR-8 Inline 15 (4) 7-210 (3000) K-34
Priority
flow PFRR-10 Inline 57 (15) 7-210 (3000) K-36
PFRR-16 Inline 152 (40) 7-210 (3000) K-38

Bypass

P T

P
Flow Typical
Model Cavity rating pressure Page
G T
Relief valve, solenoid actuated L/min (USgpm) bar (psi)
SRV-8 Inline 23 (6) 210 (3000) K-40
SRV-10 Inline 57 (15) 210 (3000) K-42
SRV-12 Inline 114 (30) 210 (3000) K-44
SRV-16 Inline 225 (60) 210 (3000) K-46
SRV-20 Inline 300 (80) 210 (3000) K-48

G T

Flow Typical
Model Cavity rating pressure Page

Cross port relief L/min (USgpm) bar (psi)


CRV-10 Inline 26 (20) 210 (3000) K-50 K
CRV-16 Inline 303 (80) 172 (2500) K-52

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-5
Circuit maker solutions
Valve locator

Functional symbol
Flow Typical
Model Cavity rating pressure Page

Regenerative valve, pressure L/min (USgpm) bar (psi)

RGV-30 Inline 57 (15) 210 (3000) K-54


RGV-90 Inline 114 (30) 210 (3000) K-56

V C

CH

Flow Typical
Model Cavity rating pressure Page

Regenerative valve, pressure L/min (USgpm) bar (psi)


RLV-30 Inline 57 (15) 210 (3000) K-58
RLV-90 Inline 114 (30) 210 (3000) K-60

V C

VH CH

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-6 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Circuit maker solutions
Valve locator

Functional symbol Flow Typical


Model Cavity rating pressure Page
V1 D V2 Relief valve, cross port solenoid L/min (USgpm) bar (psi)

SCR-1 114 (30) 210 (3000) K-62

G1 G2

V1 V2

V1 D V2

G1 G2

V1 V2

P2 SYSTEM

Flow Typical
T Model Cavity rating pressure Page

Unloading valve L/min (USgpm) bar (psi)


1UL255 200 (52) 350 (5000) K-64

P1 K

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-7
Circuit maker solutions
Valve locator

Functional symbol
Flow Typical
Model Cavity rating pressure Page

Motor mounted relief L/min (USgpm) bar (psi)


H & T Motors 76 (20) 210 (3000) K-68
2000 Motors 76 (20) 210 (3000) K-69
OMP 150 (40) 350 (5000) K-74
OMS 150 (40) 350 (5000) K--

A B

Flow Typical
M1 M2 Model Cavity rating pressure Page

Motor mounted OCV with brake shuttle L/min (USgpm) bar (psi)
H & T Motors 60 (15) 210 (3000) K-70
2000 Motors 60 (15) 210 (3000) K-72
OMP 30 (8) 270 (4000) K-74
OMS 90 (23) 270 (4000) K-76
V1 B1 V2

Flow Typical
M1 M2 Model Cavity rating pressure Page

Motor mounted P.O. check with brake shuttle L/min (USgpm) bar (psi)
H & T Motors 60 (15) 210 (3000) K-78
2000 Motors 60 (15) 210 (3000) K-80

V1 B1 V2

Flow Typical
M1 M2 Model Cavity rating pressure Page

CT1 CT2 Motor mounted OCV L/min (USgpm) bar (psi)


OMP 30 (8) 270 (4000) K-83
OMS 90 (23) 270 (4000) K-85

V1 V2

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-8 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Circuit maker solutions
Section overview

What are circuit makers? Cross port relief valve Features and Benefits
packages – • Quick solutions that are
Circuit Maker Products are pre-engineered packages. These These packages are used with ready to use
packages are designed with from 2 to 4 screw–in cartridge bi-directional actuators. The • Quick delivery at low cost
circuit maker provides actuator
valves for generic, repetitive circuit control functions. • Flexibility
protection from overload
All of the products in this catalog are rated at 210 bar conditions. Quick solutions:
(3000 psi) and have either SAE or BSPP port options. Our Pressure sensitive Circuit Maker packages are
selection of Circuit Maker pre-engineered packages consists of regeneration packages – pre-engineered packaged
Pressure sensitive solutions for generic,
the following basic units: repeatable requirements.
regeneration packages provide
• Single and multiple pump control packages a means of extending a They have specific coil
cylinder as fast as possible voltage, coil connector, flow
• Solenoid actuated relief valve packages settings adjustment and
without additional pump flow
• Flow control packages by diverting rod end flow to pressure setting adjustment
the head end to accelerate options that permit tailoring to
• Cross port relief packages application requirements.
the load. When the pressure
• Cross port relief with shuttle and solenoid vent in the head end reaches a Quick delivery/low cost:
• Pressure sensitive regeneration packages with and predetermined level related
Circuit Maker packages have
to the load, the valve closes
without load locking off and the cylinder returns
already been engineered to
satisfy generic, repetitive
• Motor mounted counterbalance valve to normal speed. Typical
circuit needs. There are no
applications are for outriggers/
• Motor mounted PO check valves scheduling or time related
stabilizers in mobile markets
problems, or engineering
• Motor mounted relief valves and machine tool traverse in
charges to be recovered.
industrial markets.
Typical applications Solenoid actuated relief Flexibility:
Pressure sensitive
Circuit Maker packages can valve packages – regeneration packages with Screw-in cartridge valves
be used in a wide variety of These can be used wherever load locking – and housings are sold
stationary and, on and off remote relief or venting either separately or as
Pressure sensitive
highway applications. The are control is required for flows pre–assembled packages.
regeneration packages
designed to solve a multitude up to 300 L/min (80 USgpm). This permits last minute
provide a means of extending
of repeatable, generic Normally open versions assembly of packages and
a cylinder as fast as possible
application requirements that lend themselves to markets local tailoring of individual
without additional pump flow
are encountered in day to where fail safe and “dead valve options.
by diverting rod end flow to
day hydraulic circuits. These man” control are important. the head end to accelerate
packages are ideal solutions Normally closed versions lend the load. When the pressure
for specialty machine themselves to markets such in the head end reaches a
requirements and low volume as machine tool, where predetermined level related
options on high volume energy savings can be to the load, the valve closes
applications. obtained by selective off and the cylinder returns
unloading of pump flow. to normal speed. The load
Pump control packages –
Flow control packages – locking feature provides
These are suitable for any stability as the system is now
single or multiple pump These packages are used with working with an oil column
application where individual both fixed and variable pump under pressure in addition
pump output flow does not systems to provide constant to the mechanical structure.
exceed 228 l/min (60 USgpm). output flow for the main or Typically used with mobile
They are used to provide branch circuits. Packages crane and other similar
air-bleed, start-up and relief offered provide for maintaining
protection. either:
vehicles to ensure stability
when swinging loads. This
K
• Cylinder or motor speed; package has an advantage
free reverse flow for table over alternative systems
positioning, that use solenoid actuated
conveyor systems and blocking pins. In the event of a
presses. power failure, it is still possible
• Controlled flow for to lower the vehicle/load.
steering systems.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-9
FC-1 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 36 L/min (9 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a circuit where adjustments is required. full flow range adjustment,
flow rates must be constantly aluminum in-line type housing,
maintained, regardless of Screw and knob adjustment
changes in upstream or options. All components in the
downstream pressure. package are true cartridges
and can be removed from the
housing without disturbing the
plumbing.
Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49° C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 36 L/min (9 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Viton is a registered trademark of E. I. DuPont
In

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
package 10 40

30

Flow rate - L/min


Flow rate - USgpm

5 20

10

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-10 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FC-1 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 36 L/min (9 USgpm) • 210 bar (3000 psi)

Model code FC – 1 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow control (Only required if valve has
5 Port size special features, omitted if
2 Maximum rated flow Code Port size Housing number
"00".)
1 - 34 L/min (9 USgpm)
4G 1/2" BSPP 02-178279

3 Seal material 8T SAE 8 02-178280


Blank - Buna-N
6 Adjustment type Flow rate
V - Viton®
Viton is a registered trademark K1 - Knob* 19 L/min (5 USgpm)
of E. I. DuPont. K2 - Knob 34 L/min (9 USgpm)
S1 - Screw 34 L/min (9 USgpm)
H1 - Handwheel 34 L/min (9 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 Knob MRV2-10-K-0-05 Flow restrictor, adjustable, semi-rotary spool 19 L/min (5 USgpm)


K2 - Knob MRV2-10-K-0-10 Flow restrictor, adjustable, semi-rotary spool 34 L/min (9 USgpm)
S1 - Screw FCV7-10-S-0-NV Flow restrictor, adjustable, needle type 34 L/min (9 USgpm)
H1 - Hand Knob FCV7-10-K-0-NV Flow restrictor, adjustable, needle type 34 L/min (9 USgpm)
– PCS3-10-0-80 Pressure compensator, spool type 40 L/min (12 USgpm)

Dimensions
mm (inch)
FCV7-10-*-0-NV
FCV7-10-*-0-NV oror
MR V2-10-K-0-*
MRV2-10-K-0-**

Ø 8,7 36,0
(Ø 0.34) (1.42)
thru 2 plcs.
19,0 IN
38,1 ( 0.75)
40,3
(1.59) (1.50)

65,2
REG. 75,4
(2.97) K
(2.57)

11,9 (0.47)

17,7 ( 0.70)
88,1 (3.47) 19,0 ( 0.75)
100,8 (3.97) 37,3 (1.47)

PCS3-10-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-11
FC-2 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 57 L/min (15 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a circuit where adjustments is required. full flow range adjustment,
flow rates must be constantly aluminum in-line type housing,
maintained, regardless of Screw and knob adjustment
changes in upstream or options. All components in the
downstream pressure. package are true cartridges
and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 57 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
In
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
package. 20 80

60
Flow rate - USgpm

15
Flow rate - L/min

10 40

20
5

0 0
0 500 1000 1500 2000 2500
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-12 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FC-2 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 57 L/min (15 USgpm) • 210 bar (3000 psi)

Model code FC – 2 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow control (Only required if valve has special
5 Port size features, omitted if "00".)
2 Maximum rated flow
2 - 57 L/min (15 USgpm) Code Port size Housing number

6G 3/4" BSPP 02-178281


3 Seal material 12T SAE 12 02-178282
Blank - Buna-N
V - Viton®
6 Adjustment type Flow rate
Viton is a registered trademark
of E.I. DuPont K1 - Knob* 38 L/min (10 USgpm)
K2 - Knob 57 L/min (15 USgpm)
S1 - Screw 57 L/min (15 USgpm)
H1 - Handwheel 57 L/min (15 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 Knob MRV2-10-K-0-10 Flow restrictor, adjustable, semi-rotary spool 38 L/min (10 USgpm)
K2 - Knob MRV2-10-K-0-15 Flow restrictor, adjustable, semi-rotary spool 57 L/min (15 USgpm)
S1 - Screw FCV7-10-S-0-NV Flow restrictor, adjustable, needle type 57 L/min (15 USgpm)
H1 - Hand Knob FCV7-10-K-0-NV Flow restrictor, adjustable, needle type 57 L/min (15 USgpm)
– PCS3-16-0-80 Pressure compensator, spool type 114 L/min (30 USgpm)

Dimensions FCV7-10-*-0-NV or
mm (inch) MRV2-10-K-0-**

36,3
Ø 8,7 (1.43)
( Ø 0.34)
thru 2 plcs. 21,5 IN
44,4 (0.85)
59,6 (1.75)
(2.35)
103,3 REG 113,5
(4.07) (4.47) K

28,4
(1.12)
11,9 (0.47)
24,6 ( 0.97)
100,8 (3.97)
50,0 (1.97)
113,5 (4.47)
PCS3-16-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-13
FC-3 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 114 L/min (30 USgpm) • 210 bar (300 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a circuit where adjustments is required. full flow range adjustment,
flow rates must be constantly aluminum in-line type housing,
maintained, regardless of Screw and knob adjustment
changes in upstream or options. All components in the
downstream pressure. package are true cartridges
and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 114 L/min (30 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
In

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control
package. 0 50 100 150 200
30
100
Flow rate - USgpm

Flow rate - L/min


80
20
60

10 40

20

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-14 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FC-3 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 114 L/min (30 USgpm) • 210 bar (300 psi)

Model code FC – 3 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow control
(Only required if valve has
5 Port size special features, omitted if "00".)
2 Maximum rated flow
3 - 114 L/min (30 USgpm) Code Port size Housing number

8G 1" BSPP 02-178283


3 Seal material 16T SAE 16 02-178284
Blank - Buna-N
V - Viton®
6 Adjustment type Flow rate
Viton is a registered trademark of
E.I. DuPont K1 - Knob* 76 L/min (20 USgpm)
K2 - Knob 114 L/min (30 USgpm)
S1 - Screw 114 L/min (30 USgpm)
H1 - Handwheel 114 L/min (30 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 - Knob MRV2-16-K-0-20 Flow restrictor, adjustable, semi-rotary spool 76 L/min (20 USgpm)
K2 - Knob MRV2-16-K-0-30 Flow restrictor, adjustable, semi-rotary spool 114 L/min (30 USgpm)
S1 - Screw FCV6-16-S-0-NV Flow restrictor, adjustable 114 L/min (30 USgpm)
H1 - Hand Knob FCV6-16-K-0-NV Flow restrictor, adjustable 114 L/min (30 USgpm)
– PCS3-16-0-80 Pressure compensator, spool type 114 L/min (30 USgpm)

Dimensions FCV6-16-*-0-NV or
mm (inch) MRV2-10-K-0-**
Ø 10,7 46,2
(Ø 0.42) (1.82)
thru 2 plcs.
25,4 IN
(1.00)
59,1 53,3
(2.33)(2.10)
100,8 REG
113,5
(3.97)
(4.47) K

28,9
(1.14)
17,0 ( 0.67) 28,4 (1.12)
126,2 (4.97) 56,3 ( 2.22)
138,9 (5.47)
PCS3-16-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-15
FC-4 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 190 L/min (50 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a circuit where adjustments is required. full flow range adjustment,
flow rates must be constantly aluminum in-line type housing,
maintained, regardless of Screw and knob adjustment
changes in upstream or options. All components in the
downstream pressure. package are true cartridges
and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 190 L/min (50 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
In

Description Pressure Characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
package. 60
200
50
160
Flow rate - USgpm

40 Flow rate - L/min


120
30
80
20

10 40

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-16 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FC-4 - Flow control
Pressure compensated, restrictive type, full range adjustable
Up to 190 L/min (50 USgpm) • 210 bar (3000 psi)

Model code FC – 4 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow control (Only required if valve has
5 Port size special features, omitted if "00".)
2 Size
Code Port size Housing number
4 - 190 L/min (50 USgpm)
12G 1 1/4" BSPP 02-178285
20T SAE 20 02-178286
3 Seal material
Blank - Buna-N
6 Adjustment type Flow rate
V - Viton®
Viton is a registered trademark of K1 - Knob* 190 L/min (50 USgpm)
E.I. DuPont *180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow
K1 - Knob NV1-20-K-0 Needle Valve 190 L/min (50 USgpm)
– PCS3-20-0-80 Pressure compensator, spool type 200 L/min (53 USgpm)

Dimensions NV1-20-K-0
mm (inch)

Ø 13,4 59,6
(Ø 0.53) (2.35)
thru 2 plcs.
31,7 IN
66,0 (1.25)
79,2 (2.60)
(3.12)

133,8 REG 151,6


(5.27)
(5.97)

K
19,5 ( 0.77)
41,9
(1.65)

159,2 (6.27) 32,3 (1.27)


177,0 (6.97) 62,7 (2.47)
PCS3-20-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-17
FRC-1 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 36 L/min (9 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a hydraulic circuit adjustments is required. It also full flow range adjustment,
where flow rates must provides free reverse flow. aluminum in-line type housing,
be constantly maintained, Screw and knob adjustment
regardless of changes in options. All components in the
upstream or downstream package are true cartridges
pressure. and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 36 L/min (9 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
In

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
10 40
package with free reverse
flow.
30
Flow rate - USgpm

Flow rate - L/min


5 20

10

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-18 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FRC-1 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 36 L/min (9 USgpm) • 210 bar (3000 psi)

Model code FRC – 1 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FRC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow (Only required if valve has special
control with reverse 5 Port size features, omitted if "00".)
flow check
Code Port size Housing number

2 Maximum rated flow 4G 1/2" BSPP 02-178287


1 - 34 L/min (9 USgpm) 8T SAE 8 02-178288

3 Seal material 6 Adjustment type Flow rate


Blank - Buna-N
V - Viton® K1 - Knob* 19 L/min (5 USgpm)
K2 - Knob 34 L/min (9 USgpm)
Viton is a registered trademark of E.I.
DuPont S1 - Screw 34 L/min (9 USgpm)
H1 - Handwheel 34 L/min (9 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 - Knob MRV2-10-K-0-05 Flow restrictor, adjustable, semi-rotary spool 19 L/min (5 USgpm)


K2 - Knob MRV2-10-K-0-10 Flow restrictor, adjustable, semi-rotary spool 34 L/min (9 USgpm)
S1 - Screw FCV7-10-S-0-NV Flow restrictor, adjustable, needle type 34 L/min (9 USgpm)
H1 - Hand Knob FCV7-10-K-0-NV Flow restrictor, adjustable, needle type 34 L/min (9 USgpm)
– CV3-10-P-0-10 Check valve 76 L/min (20 USgpm)
– PCS3-10-0-80 Pressure compensator, spool type 40 L/min (12 USgpm)

Dimensions
mm (inch) FCV7-10-*-0-NV or
MRV2-10-K-0-**

Ø 8,7
CV3-10-P-0-10 36,0
(Ø 0.34)
(1.42)
thru 2 plcs.
19,0 IN
40,3 38,1 (0.75)

65,2
(1.59) (1.50)
75,4
K
REG
(2.57) (2.97)

37,3 17,7 (0.70)


(1.47)
19,5 ( 0.77)
113,5 (4.47)
37,3 (1.47)
126,2 (4.97)
PCS3-10-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-19
FRC-2 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 57 L/min (15 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a hydraulic circuit adjustments is required. It also full flow range adjustment,
where flow rates must provides free reverse flow. aluminum in-line type housing,
be constantly maintained, Screw and knob adjustment
regardless of changes in options. All components in the
upstream or downstream package are true cartridges
pressure. and can be removed from the
housing without disturbing the
plumbing.

Performance data

Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 57 L/min (15 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
In
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
20 80
package with free reverse
flow.
60
Flow rate - USgpm

15

Flow rate - L/min


10 40

20
5

0 0
0 500 1000 1500 2000 2500
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-20 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FRC-2 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 57 L/min (15 USgpm) • 210 bar (3000 psi)

Model code FRC – 2 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FRC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow (Only required if valve has special
control with reverse features, omitted if "00".)
5 Port size
flow check
Code Port size Housing number
2 Maximum rated flow 6G 3/4" BSPP 02-178289
2 - 57 L/min (15 USgpm) 12T SAE 12 02-178290

3 Seal material
6 Adjustment type Flow rate
Blank - Buna-N
V - Viton® K1 - Knob* 38 L/min (10 USgpm)
Viton is a registered trademark of E.I. K2 - Knob 57 L/min (15 USgpm)
DuPont S1 - Screw 57 L/min (15 USgpm)
H1 - Handwheel 57 L/min (15 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 - Knob MRV2-10-K-0-10 Flow restrictor, adjustable, semi-rotary spool 38 L/min (10 USgpm)
K2 - Knob MRV2-10-K-0-15 Flow restrictor, adjustable, semi-rotary spool 57 L/min (15 USgpm)
S1 - Screw FCV7-10-S-0-NV Flow restrictor, adjustable, needle type 57 L/min (15 USgpm)
H1 - Hand Knob FCV7-10-K-0-NV Flow restrictor, adjustable, needle type 57 L/min (15 USgpm)
– CV3-10-P-0-10 Check valve 76 L/min (20 USgpm)
– PCS3-16-0-80 Pressure compensator, spool type 114 L/min (30 USgpm)

Dimensions
mm (inch) FCV7-10-*-0-NV or
MRV2-10-K-0-**

CV3-10-P-0-10 Ø 8,7 36,3


(1.43)
(Ø 0.34)
thru 2 plcs.
21,5 IN
44,4 (0.85)
59,6 (1.75)
(2.35) K
103,3 113,5
(4.07) REG
(4.47)

24,6 (0.97) 28,4


(1.12)

113,5 ( 4.47) 24,6 (0.97)


126,2 (4.97) 50,0 (1.97)
PCS3-16-0-80
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-21
FRC-3 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 114 L/min (30 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a hydraulic circuit adjustments is required. It also full flow range adjustment,
where flow rates must provides free reverse flow. aluminum in-line type housing,
be constantly maintained, Screw and knob adjustment
regardless of changes in options. All components in the
upstream or downstream package are true cartridges
pressure. and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 114 L/min (30 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
In MIL-H-5606, SAE 10, SAE 20, etc.

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
package with free reverse 30
flow. 100
Flow rate - USgpm

Flow rate - L/min


80
20
60

10 40

20

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-22 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FRC-3 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 114 L/min (30 USgpm) • 210 bar (3000 psi)

Model code FRC – 3 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FRC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow (Only required if valve has special
control with reverse features, omitted if "00".)
flow check 5 Port size
Code Port size Housing number
2 Maximum rated flow
8G 1" BSPP 02-178291
3 - 115 L/min (30 USgpm)
16T SAE 16 02-178292
3 Seal material
Blank - Buna-N 6 Adjustment type Flow rate
V - Viton®
K1 - Knob* 76 L/min (20 USgpm)
Viton is a registered trademark of E.I. K2 - Knob 114 L/min (30 USgpm)
DuPont S1 - Screw 114 L/min (30 USgpm)
H1 - Handwheel 114 L/min (30 USgpm)
*180˚ rotation

Composition chart
Adjustment Cartridge Description Maximum flow

K1 - Knob MRV2-16-K-0-20 Flow restrictor, adjustable, semi-rotary spool 76 L/min (20 USgpm)
K2 - Knob MRV2-16-K-0-30 Flow restrictor, adjustable, semi-rotary spool 114 L/min (30 USgpm)
S1 - Screw FCV6-16-S-0-NV Flow restrictor, adjustable, needle type 114 L/min (30 USgpm)
H1 - Hand Knob FCV6-16-K-0-NV Flow restrictor, adjustable, needle type 114 L/min (30 USgpm)
– CV1-16-P-0-5 Check valve 151 L/min (40 USgpm)
– PCS3-16-0-80 Pressure compensator, spool type 114 L/min (30 USgpm)

Dimensions
mm (inch)
FCV6-16-*-0-NV or
MRV2-16-K-0-**

CV1-16-P-0-5 46,2
(1.82)
Ø 10,7
(Ø 0.42)
thru 2 plcs. 25,4 IN
53,3
59,1 (2.10) (1.00) K
(2.33)
100,8 REG 113,5
(3.97) (4.47)

55,1 28,9
(2.17) (1.14)
164,3 (6.47) 28,4 (1.12)
177,0 (6.97) 56,3 (2.22)
PCS3-16-0-80

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-23
FRC-4 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 190 L/min (50 USgpm) • 210 bar (3000 psi)

Reg. Operation Features


This standard valve package Also where a full range of flow Pressure compensation,
is used in a hydraulic circuit adjustments is required. It also full flow range adjustment,
where flow rates must provides free reverse flow. aluminum in-line type housing,
be constantly maintained, Screw and knob adjustment
regardless of changes in options. All components in the
upstream or downstream package are true cartridges
pressure. and can be removed from the
housing without disturbing the
plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regulated flow Up to 190 L/min (50 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
In

Description Performance characteristics


Full range adjustable
restrictive pressure Pressure drop - bar
compensated flow control 0 50 100 150 200
package with free reverse 60
flow. 200
50
Flow rate - USgpm

160
40 Flow rate - L/min
120
30
80
20

10 40

0 0
0 500 1000 1500 2000 2500 3000
Pressure drop - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-24 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
FRC-4 - Flow control
Pressure compensated, restrictive type, full range adjustable with reverse flow check
Up to 190 L/min (50 USgpm) • 210 bar (3000 psi)

Model code FRC – 4 (V) – A ** – ** – 00

1 2 3 4 5 6 7

1 Function 4 Valve housing material 7 Special features


FRC - Fully adjustable pressure A - Aluminum 00 - None
compensated flow (Only required if valve has special
control with reverse 5 Port size features, omitted if "00".)
flow check
Code Port size Housing number
2 Maximum rated flow 12G 1 1/4" BSPP 02-178293
4 - 190 L/min (50 USgpm) 20T SAE 20 02-178294

3 Seal material
6 Adjustment type Flow rate
Blank - Buna-N
V - Viton® K1 - Knob* 190 L/min (50 USgpm)
Viton is a registered trademark of E.I. *180˚ rotation
DuPont

Composition chart
Adjustment Cartridge Description Maximum flow

K1 - Knob NV1-20-K-0 Needle valve 190 L/min (50 USgpm)


– CV2-20-P-0-5 Check valve 220 L/min (60 USgpm)
– PCS3-20-0-80 Pressure compensator, spool type 200 L/min (53 USgpm)

Dimensions
mm (inch)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-25
PCC1-12 - Pump control
Single pump circuits
Up to 114 L/min (30 USgpm) • 5-210 bar (75-3000 psi)

S2 T2 Operation Features
This standard valve package is Multiple tank ports for Aluminum in-line type
used for air-bleed and start-up mounting convenience, direct housing, Tamper proof and
in single pump power units. reservoir mounting capability adjustable relief options,
It also provides main system by using T port. Both T port gauge port. All components
G T1
relief protection. and mounting holes have in the package are true
O-ring seals mounting surface. cartridges and can be
removed from the housing
without disturbing the plumbing.
Performance data

Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 5-210 bar (75-3000 psi)
Maximum regulated flow Up to 114 L/min (30 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
P T Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop Pressure override


Pump control manifold for
single pump circuits.
Flow - L/min (21,8 cSt oil @ 49˚) Flow - L/min (21,8 cSt oil @ 49˚)
0 20 40 60 80 100 20 40 60 80 100
300 18 6000 414
16 5000
250 345
Pressure Drop - psi

Pressure Drop - bar

Inlet pressure - bar


Inlet pressure - psi

200 4000 276


12
150 3000 210
100 6 2000 138
50 4
1000 69
2
0 0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @ 120˚ F)
Cartridge w/ C-12-2 Cavity

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-26 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PCC1-12 - Pump control
Single pump circuits
Up to 114 L/min (30 USgpm) • 5-210 bar (75-3000 psi)

Model code PCC1 – 12 (V) – * – A ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 4 Relief control 7 Pressure range 8 Pressure setting -


PCC1 - Pump control for single C - Cap Note: Code based on pressure user requested in 50 psi steps.
pump circuits K - Knob in psi. Example:
S - Screw 15 - 5-100 bar (75-1500 psi) 10 - 1000 psi
2 Size 30 - 10-210 bar (150-3000 psi) 10.5 - 1050 psi
12 - 12 size 5 Valve housing material
A - Aluminum 9 Special features
3 Seal material 00 - None
Blank - Buna-N 6 Port size (Only required if valve has special
V - Viton® features, omitted if "00".)
Viton is a registered trademark of E.I. Code P, SYS, T2 T1 Gauge
DuPont 6G 3/4" BSPP 1/2" BSPP 1/4" BSPP
12T SAE 12 SAE 8 SAE 4

Composition chart

Cartridge Description Maximum flow Quantity

VF1-10-F-0-.25 Velocity fuse 23 L/min (6 USgpm) 1


CV11-12-P-0-20 Check valve 113 L/min (30 USgpm) 1
RV11-12-*-0-** Relief valve 113 L/min (30 USgpm) 1

Dimensions
RV11-12-*-0-**
mm (inch)

72,6
VF1-10-F-0-.25 (2.86)
28,7
34,2 (1.35) (1.13)
Ø 0.42 (Ø 0.41)
thru 2 plcs.
56,5 Ø 0.68 (Ø 0.59) T2 34,2
(2.23) T1 cbore x .31 dp (1.35)
81,2 110,2
(3.20) (4.34)
110,2 138,9 T
(4.34) (5.47)
P
SYS
G
K
CV11-12-P-0-20

17,0 (0.67) 17,7 (0.70)


58,4 (2.30) 24,6 (0.97)
82,5 (3.25)
99,5 (3.92) 62,7(2.47)
126,2 (4.97)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-27
PCC1-16 - Pump control
Single pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)

S2 T2 Operation Features Aluminum in-line type


This standard valve package is Multiple tank ports for housing, Tamper proof and
used for air-bleed and start-up mounting convenience, direct adjustable relief options,
in single pump power units. reservoir mounting capability gauge port. All components
It also provides main system by using T port. Both T port in the package are true
relief protection. and mounting holes have cartridges and can be
G T1
O-ring seals mounting surface. removed from the housing
without disturbing the plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 10-210 bar (150-3000 psi)
Maximum regulated flow Up to 228 L/min (60 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
P T
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop Pressure override


Pump control manifold for
single pump circuits.
Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
40 80 120 160 200 240 50 100 150 200 250 300
150 10 6000 414

125 5000 345


8
Pressure Drop - psi

Pressure Drop - bar

Inlet pressure - bar


Inlet pressure - psi

100 4000 276


6
75 3000 210
4
50 2000 138
2
25 1000 69
0 0
0 10 20 30 40 50 60 0 20 40 60 80
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @ 120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-28 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PCC1-16 - Pump control
Single pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)

Model code PCC1 – 16 (V) – * – A ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 4 Relief control 7 Pressure range 9 Special features


PCC1 - Pump control for single C - Cap NNote: Code based on pressure 00 - None
pump circuits K - Knob in psi.
(Only required if valve has special
S - Screw 30 - 10-210 bar (150-3000 psi) features, omitted if "00".)
2 Size
16 - 16 size 5 Valve housing material 8 Pressure setting -
A - Aluminum user requested in 50 psi steps.
3 Seal material Example:
Blank - Buna-N 10 - 1000 psi
V - Viton® 10.5 - 1050 psi
Viton is a registered trademark of E.I.
DuPont 6 Port size
Code P, SYS, T2 T1 Gauge

8G 1" BSPP 3/4" BSPP 1/4" BSPP


16T SAE 16 SAE 8 SAE 4

Composition chart
Cartridge Description Maximum flow Quantity

VF1-10-F-0-.25 Velocity fuse 23 L/min (6 USgpm) 1


CV2-20-P-0-30 Check valve 228 L/min (60 USgpm) 1
RV5-16-*-0-30 Relief valve 303 L/min (80 USgpm) 1

Dimensions RV5-16-*-0-**-30/
mm (inch)

63,5
VF1-16-F-0-.25 (2.50) 25,4
29,2 (1.15) (1.00)
Ø 0,42 (Ø 0.41)
thru 2 plcs.
56,1 Ø 0.68 (Ø 0.59) T2 29,2
T1 (1.15)
81,2 (2.21) cbore x .31 dp
(3.20) 119,8
(4.72)
119,8 151,6 T
(4.72) (5.97)
P
SYS K
G

CV2-20-P-0-30

15,2 ( 0.60) 13,4 (0.53)


66,0 (2.60)
97,7 (3.85) 33,5 (1.32)
116,8 (4.60) 75,4 (2.97)
151,6 (5.97)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-29
PCC2-12 - Pump control
Multiple pump circuits
Up to 114 L/min (30 USgpm) • 5-210 bar (75-3000 psi)

S2 T2 Operation Features Aluminum in-line type


This standard valve package Individual relief pressure housing, tamper proof and
is used to provide air-bleed, setting for each pump in the adjustable relief options,
start-up and relief protection system, multiple tank ports for gauge port. All components
for each pump in multiple mounting convenience, direct in the package are true
pump circuits. The check valve reservoir mounting capability cartridges and can be
G T1
position in the circuit isolates by using T port. Both T port removed from the housing
the other pumps from the and mounting holes have without disturbing the plumbing.
valve assembly. O-ring seals mounting surface.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 5 - 210 bar (75 - 3000 psi)
Maximum regulated flow Up to 114 L/min (30 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
P T
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop Pressure override


Pump control manifold for
multiple pump circuits. Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
0 20 40 60 80 100 20 40 60 80 100
300 18 6000 414
16
250 5000 345
Pressure Drop - bar
Pressure Drop - psi

Inlet pressure - psi

Inlet pressure - bar


200 4000 276
12
150 3000 210

100 6 2000 138


4
50 1000 69
2
0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @ 120˚ F)
Cartridge w/ C-12-2 Cavity

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-30 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PCC2-12 - Pump control
Multiple pump circuits
Up to 114 L/min (30 USgpm) • 5-210 bar (75-3000 psi)

Model code PCC2 – 12 (V) – * – A ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 4 Relief control 7 Pressure range 9 Special features


PCC2 - Pump control for single C - Cap NNote: Code based on pressure 00 - None
pump circuits K - Knob in psi.
(Only required if valve has special
S - Screw 15 - 5-100 bar (75-1500 psi) features, omitted if "00".)
2 Size 30 - 10-210 bar (150-3000 psi)
12 - 12 size 5 Valve housing material
A - Aluminum 8 Pressure setting -
3 Seal material user requested in 50 psi steps.
Blank - Buna-N Example:
V - Viton® 10 - 1000 psi
Viton is a registered trademark of E.I. 10.5 - 1050 psi
DuPont
6 Port size

Code P, SYS, T2 T1 Gauge

6G 3/4" BSPP 1/2" BSPP 1/4" BSPP


12T SAE 12 SAE 8 SAE 4

Composition chart
Cartridge Description Maximum flow Quantity

VF1-10-F-0-.25 Velocity fuse 23 L/min (6 USgpm) 1


CV11-12-P-0-20 Check valve 113 L/min (30 USgpm) 1
RV11-12-*-0-**/ Relief valve 113 L/min (30 USgpm) 1

RV11-12-*-0-**
Dimensions
mm (inch)
72,6
(2.86)
VF1-10-F-0-.25 28,7
(1.13)
Ø 0,42 (Ø 0.41)
thru 2 plcs. T2
34,2 34,2
56,6 (1.35) Ø 0.68 (Ø 0.59) (1.35)
T1 cbore x .31 dp
81,2 (2.23) 110,2
(3.20) (4.34)
T
138,9
P
G
(5.47) K
SYS

17,0 (0.67) 17,7


58,4 (2.30) (0.70)
82,5 (3.25) 24,6 (0.97)
99,5 (3.92) 62,7 (2.47)
126,2 (4.97) CV11-12-P-0-20

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-31
PCC2-16 - Pump control
Multiple pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)

S2 T2 Operation Features
This standard valve package Individual relief pressure Aluminum in-line type
is used to provide air-bleed, setting for each pump in the housing, tamper proof and
start-up and relief protection system, multiple tank ports for adjustable relief options,
for each pump in multiple mounting convenience, direct gauge port. All components
G T1
pump circuits. The check valve reservoir mounting capability in the package are true
position in the circuit isolates by using T port. Both T port cartridges and can be
the other pumps from the and mounting holes have removed from the housing
valve assembly. O-ring seals mounting surface. without disturbing the plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range (all ports) 10-210 bar (150-3000 psi)
Maximum regulated flow Up to 228 L/min (60 USgpm)
Temperature range -40° to 120°C (-40° to 248°F)
P T
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop Pressure override


Pump control manifold for
multiple pump circuits. Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
40 80 120 160 200 240 50 100 150 200 250 300
150 6000 414
10
125 5000 345
Pressure Drop - psi

Pressure Drop - bar

Inlet pressure - bar


Inlet pressure - psi

100 4000 276


6
75 3000 210
50 4 2000 138

25 2 1000 69
0� 0
0 10 20 30 40 50 60 0 20 40 60 80
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @ 120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-32 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PCC2-16 - Pump control
Multiple pump circuits
Up to 228 L/min (60 USgpm) • 10-210 bar (150-3000 psi)

Model code PCC2 16 (V) * A ** ** / ** 00

1 2 3 4 5 6 7 8 9

1 Function 4 Relief control 7 Pressure range 9 Special features


PCC2 - Pump control for single C - Cap NNote: Code based on pressure 00 - None
pump circuits K - Knob in psi.
(Only required if valve has special
S - Screw 30 - 10-210 bar (150-3000 psi) features, omitted if "00".)
2 Size
16 - 16 size 5 Valve housing material 8 Pressure setting -
A - Aluminum user requested in 50 psi steps.
3 Seal material Example:
Blank - Buna-N 10 - 1000 psi
V- Viton® 10.5 - 1050 psi
Viton is a registered trademark of E.I.
DuPont 6 Port size
Code P, SYS, T2 T1 Gauge

8G 1" BSPP 3/4" BSPP 1/4" BSPP


16T SAE 16 SAE 12 SAE 4

Composition chart
Cartridge Description Maximum flow Quantity

VF1-10-F-0-.25 Velocity fuse 23 L/min (6 USgpm) 1


CV2-20-P-0-30 Check valve 228 L/min (60 USgpm) 1
RV5-16-*-0-30/ Relief valve 303 L/min (80 USgpm) 1

Dimensions RV5-16-*-0-30/
mm (inch)

63,5
VF1-10-F-0-.25 (2.50)

Ø 0,42 (Ø 0.41)
thru 2 plcs. T2
29,2 25,4 29,2
56,1 (1.15) Ø 0.68 (Ø 0.59) (1.00)
T1 cbore x .31 dp (1.15)
(2.21)
81,2 119,8
(3.20) (4.72)
T
151,6
G (5.97)
P
SYS K

15,2 (0.60) 13,4 (0.53)


66,0 (2.60)
97,7 (3.85) 33,5 (1.32)
116,8 (4.60) 75,4 (2.97)
151,6 (5.97) CV2-20-P-0-30

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-33
PFRR-8 - Flow control
Pressure compensated, priority type, with relief on priority flow
15 L/min (4 USgpm) • 7-210 bar (100-3000 psi)

G
Operation Features
This standard valve package is Relief valve on a priority port Priority flow pressure
used to maintain constant flow limits pressure on a priority compensation, all ports
Priority to priority circuits when input port, as well as ensures except T can be pressurized to
flow
flow is greater than required, bypass flow when there is no 210 bar (3000 psi). Aluminum
regardless of changes in demand on priority circuit. in-line type housing, tamper
upstream or downstream proof and adjustable relief
pressure. It will bypass the options, gauge port. All
rest of the flow to an auxiliary components in the package
circuit or to tank. are true cartridges and can
be removed from the housing
without disturbing the
Bypass plumbing.

Performance data
P T
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range 7-210 bar (100-3000 psi)
Maximum inlet flow 15 L/min (4 USgpm)
Regulated flow range 0.4-8 L/min (0.1-2.5 USgpm)
Internal leakage 82 cm3/min (5 in3/min) max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Typical flow regulation


Fixed priority flow control with
relief on priority flow port. Pressure - bar
Flow - USgpm (105 SUS oil @ 120˚ F)

350 280 210 140 70 0 70 140 210 280 350


12 3.0
Flow - L/min (21,8 cSt oil @ 49˚ C)

10 2.5

8 2.0

6 1.5

4 1.0

2 0.5
0 0
5000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000
Bypass pressure Priority pressure
K higher than priority higher than bypass
Pressure - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-34 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PFRR-8 - Flow control
Pressure compensated, priority type, with relief on priority flow
15 L/min (4 USgpm) • 7-210 bar (100-3000 psi)

Model code PFRR – 8 (V) – * – A ** – ** / ** – ** – 00

1 2 3 4 5 6 7 8 9 10

1  Function 4 Relief control 7 Pressure range 9 Flow setting

PFRR - Pressure compensated


C - Cap NNote: Code based on pressure Customer must specify flow:
K - Knob in psi. 0.4 - 8L/min (0.1 - 2.5 USgpm)
priority flow control with relief
S - Screw 3 - 3-20 bar (50-300 psi)
on priority port
20 - 40-140 bar (600-2000 psi) 10 Special features
5 Valve housing material 36 - 20-250 bar (300-3600 psi) 00 - None
2 Size
A - Aluminum (Only required if valve has special
8 - 8 size 8 Pressure setting -
features, omitted if "00".)
user requested in 50 psi steps.
3 Seal material Example:
Blank - Buna-N 10 - 1000 psi
V - Viton® 10.5 - 1050 psi
Viton is a registered trademark of 6 Port size
E.I. DuPont
Code P, Bypass Priority, T Gauge Housing number
3G 3/8" BSPP 3/8" BSPP 1/4" BSPP 02-178273
8T SAE 8 SAE 8 SAE 4 02-178274

Composition chart
Cartridge Description Quantity
PFR5-8-F-0-** Priority flow regulator 1
RV1-8-*-0-** Relief valve 1

Dimensions Ø 7,1 (Ø 0.28) PFR5-8-F-0-**


mm (inch) 12,7 (0.50) thru 2 plcs. 8,6 ( 0.34) 15,4 (0.61)
15,4 (0.61)
G
27,9
(1.10) Bypass 59,9
63,5 (2.36)
(2.50) Pri
75,4 T
P (2.97)
K
12,7 (0.50)
33,2 (1.31)
RV1-8-*-0-**
72,6
(2.86)

66,0 (2.60) 19,5 (0.77)


100,8 (3.97) 37,3 (1.47)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-35
PFRR-10 - Flow control
Pressure compensated, priority type, with relief on priority flow
Up to 57 L/min (15 USgpm) • 7-210 bar (100-3000 psi)

G Operation Features
This standard valve package Relief valve on a priority port Priority flow pressure
is used to maintain constant limits pressure on a priority compensation, all ports
Priority flow to priority circuits port, as well as ensures except T can be pressurized to
flow when input flow is greater bypass flow when there is no 210 bar (3000 psi). Aluminum
than required, regardless demand on priority circuit. in-line type housing, tamper
of changes in upstream or proof and adjustable relief
downstream pressure. It will options, gauge port. All
bypass the rest of the flow to components in the package
an auxiliary circuit or to tank. are true cartridges and can
be removed from the housing
without disturbing the
plumbing.
Bypass

Performance data
Ratings and specifications

P T Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range 7-210 bar (100-3000 psi)
Maximum inlet flow 57 L/min (15 USgpm)
Regulated flow range 0.38-22.7 L/min (0.1-6 USgpm)
Internal leakage 82 cm3/min (5 in3/min) max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Typical flow regulation


Fixed priority flow control with
relief on priority flow port. Back Pressure - bar
0 50 100 140 210
A - Port 3, priority 24
6
(regulated) A
20
(105 SUS oil @ 120˚ F)

outlet pressurized 5

(21,8 cSt oil @ 49˚ C)


B - Port 2, bypass B 16
4
outlet pressurized
3 12

2 A 8

1 B 4

0 0
0 500 1000 1500 2000 2500 3000
Back Pressure - psi
K

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-36 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PFRR-10 - Flow control
Pressure compensated, priority type, with relief on priority flow
Up to 57 L/min (15 USgpm) • 7-210 bar (100-3000 psi)

Model code PFRR – 10 (V) – * – A ** – ** / ** – ** – 00

1 2 3 4 5 6 7 8 9 10

1 Function 4 Relief control 7 Pressure range 9 Flow setting


PFRR - Pressure compensated C - Cap NNote: Code based on pressure Customer must specify flow:
priority flow control with relief K - Knob in psi. 0.38 - 22.7L/min (0.1 - 6
on priority port S - Screw 3 - 3-20 bar (50-300 psi) USgpm)
20 - 7-140 bar (100-2000 psi)
2 Size 5 Valve housing material 35 - 17-240 bar (250-3500 psi) 10 Special features
10 - 10 size A - Aluminum 00 - None
8 Pressure setting - (Only required if valve has special
3 Seal material user requested in 50 psi steps. features, omitted if "00".)
Blank - Buna-N Example:
V - Viton® 10 - 1000 psi
Viton is a registered trademark of 10.5 - 1050 psi
E.I. DuPont
6 Port size
Code P, Bypass Priority, T Gauge Housing number

4G 3/8" BSPP 1/2" BSPP 1/4" BSPP 02-178275


10T SAE 8 SAE 8 SAE 4 02-178276

Composition chart
Cartridge Description Quantity

PFR1-10-F-0-** Priority flow regulator 1


RV5-10-*-0-35/ Relief valve 1

Ø 8,7 (Ø 0.34) PFR1-10-F-0-**


Dimensions thru 2 plcs. 18,0 19,0
mm (inch) 10,1 ( 0.40) ( 0.71) ( 0.75)
19,0 ( 0.75)

G Priority
34,7
(1.37) 56,3
64,0 Bypass 75,4 (2.22)
(2.52) (2.97) T
P

K
10,1 ( 0.40)
37,8 (1.49)
79,2
(3.12)

73,6 (2.90) 18,2 ( 0.72)


113,5 (4.47) 37,3 (1.47)
RV5-10-*-0-**

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-37
PFRR-16 - Flow control
Pressure compensated, priority type, with relief on priority flow
152 L/min (40 USgpm) • 7-210 bar (100-3000 psi)

G Operation Features
This standard valve package is Relief valve on a priority port Priority flow pressure
used to maintain constant flow limits pressure on a priority compensation, all ports
Priority to priority circuits when input port, as well as ensures except T can be pressurized to
flow flow is greater than required, bypass flow when there is no 210 bar (3000 psi). Aluminum
regardless of changes in demand on priority circuit. in-line type housing, tamper
upstream or downstream proof and adjustable relief
pressure. It will bypass the options, gauge port. All
rest of the flow to an auxiliary components in the package
circuit or to tank. are true cartridges and can
be removed from the housing
without disturbing the
plumbing.
Bypass

Performance data
Ratings and specifications
P T
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure range 7-210 bar (100-3000 psi)
Maximum inlet flow 152 L/min (40 USgpm)
Regulated flow range 1.9-113 L/min (0.5-30 USgpm)
Internal leakage 82 cm3/min (5 in3/min) max @ 210 bar (3000 psi)
Temperature range -40° to 120°C (-40° to 248°F)
Reseat pressure 90% of crack pressure
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Typical flow regulation


Fixed priority flow control with
relief on priority flow port. Back Pressure - bar
0 50 100 140 210

A - Port 3, priority 6 24
A
(regulated)
(105 SUS oil @ 120˚ F)

5 20

(21,8 cSt oil @ 49˚ C)


outlet pressurized B
B - Port 2, bypass 16
4
outlet pressurized
3 12
A
2 8

1 B 4

0 0
0 500 1000 1500 2000 2500 3000
Back Pressure - psi
K

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-38 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
PFRR-16 - Flow control
Pressure compensated, priority type, with relief on priority flow
152 L/min (40 USgpm) • 7-210 bar (100-3000 psi)

Model code PFRR – 16 (V) – * – A ** – ** / ** – ** – 00

1 2 3 4 5 6 7 8 9 10

1  Function 4   Relief control 7   Pressure range 9   Flow setting


PFRR - Pressure compensated C - Cap NNote: Code based on pressure Customer must specify flow:
K - Knob in psi. 0.38 - 22.7L/min (0.1 - 6
priority flow control
with relief on priority S - Screw 3 - 3-20 bar (50-300 psi) USgpm)
port 20 - 7-140 bar (100-2000 psi)
35 - 17-240 bar (250-3500 psi)
5   Valve housing material 10   Special features
2  Size A - Aluminum 00 - None
8   Pressure setting -
16 - 16 size (Only required if valve has special
user requested in 50 psi steps. features, omitted if "00".)
Example:
3   Seal material
10 - 1000 psi
Blank - Buna-N 10.5 - 1050 psi
V - Viton®
Viton is a registered trademark of E.I. 6   Port size
DuPont
Code P, Bypass Priority, T Gauge Housing number

8G 1" BSPP 3/4" BSPP 1/4" BSPP 02-178277


16T SAE 16 SAE 12 SAE 4 02-178278

Composition chart
Cartridge Description Quantity

PFR1-16-F-0-** Priority flow regulator 1


RV5-10-*-0-**/** Relief valve 1

PFR1-16-F-0-**
Ø 10,7
Dimensions (Ø 0.42) 28,9 25,4
20,3 ( 0.80) (1.14) (1.00)
mm (inch) thru 2 plcs.
25,4 (1.00)

G Priority
53,5
(2.11) 91,9
90,1 Bypass 113,5 (3.62)
(3.55) (4.47) T
P
K
20,3 ( 0.80)
53,5 (2.11)
79,5
(3.13)

96,5 (3.80) 24,6 ( 0.97)


138,9 (5.47) 50,0 (1.97)
RV5-16-*-0-**

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-39
SRV-8 - Unloading/relief valve
Normally open or normally closed
23 L/min (6 USgpm) • 210 bar (3000 psi)

Normally Closed Version Operation Features


P This standard valve package is Normally closed and normally All components in the package
designed for pump unloading open options, tamper proof or are true cartridges and can
via solenoid valve activation adjustable relief options. Low be removed from the housing
and pump relief, when the power requirements, gauge without disturbing the plumbing.
G T
solenoid valve is not activated port. Aluminum in-line type
and system pressure reaches housing, number of voltage
relief valve setting. and connector options.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)

P
Typical application pressure (all ports) 210 bar (3000 psi)
Flow rating 23 L/min (6 USgpm)
Normally Open Version Internal leakage 5 drops/min @ 80% of crack pressure
P
Reseat pressure 80% of crack pressure
Typical vented ΔP 4 bar (60 psi) at rated flow
Coil specifications Power requirements: 16 watts
G T Coil duty: Continuous from 85% to 110% of nominal voltage
(AC coils are internally rectified)
Temperature range -40° to 120° C (-40° to 248° F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop (unloading) Pressure override


Solenoid actuated relief valve.
Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
0 4 8 12 16 20 0 4 8 12 16 18 20
K 200 5000 345

12 4000
Pressure Drop - psi

Inlet Pressure - bar


Pressure Drop - bar

Inlet Pressure - psi

150 270

8 3000 210
100
2000 140

50 4
1000 70

0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-40 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SRV-8 - Unloading/relief valve
Normally open or normally closed
23 L/min (6 USgpm) • 210 bar (3000 psi)

Model code SRV – 8 (V) – * – * – A ** – ** / *** – ** – 00

1 2 3 4 5 6 7 8 9 10 11

1  Function 5   Relief control 8   Relief Pressure range 10   Connector types


SRV - Solenoid actuated P - leakproof screw adjustment NNote: Code based on pressure GS - ISO 4400 DIN 43650
relief valve R - Handknob adjustment in psi. connector
G - Tamperproof cap (See page 10 - 7-100 bar (100-1450 psi) PS - 1/2" NPT conduit
E-7 for dimensions) 20 - 35 - 210 bar (500-3000 psi) WS - Lead wire
2  Size
8 - 8 size
6   Valve housing material 9   Voltage rating 11   Special features
A - Aluminum 12D - 12 VDC 00 - None
3   Seal material
24D - 24 VDC (Only required if valve has special
Blank - Buna-N 120A - 120 VAC features, omitted if "00".)
V - Viton® 240A - 240 VAC
Viton is a registered trademark of
E.I. DuPont 7   Port size
Code P, T Gauge Housing number
4  Type 3G 3/8" BSPP 1/4" BSPP 02-178306
C - Normally closed 8T SAE 8 SAE 4 02-178307
O - Normally open

Composition chart
Cartridge Description Quantity

SV5-8-0-0-** 2 way/2 position N.O. poppet solenoid valve 1


SV5-8-C-0-** 2 way/2 position N.C. poppet solenoid valve 1
1DR30-*-**-* Relief valve, direct acting 1

Dimensions
mm (inch) SV5-8-C-0-** or
SV5-8-0-0-**
NO
64,2
8,8 (0.35) NC (2.53)
50,2
15,4 (0.61) (1.98)

P
55,6 43,6
(2.19) (1.72) Ø 7,1 62,7 15,4 G
15,4
P (0.61)
T (Ø 0.28) (2.47) (0.61)
thru 2 plcs.
K
8,8 ( 0.35)
27,9 (1.10) 70.0
(2.76)

50,8 (2.00) 18,5 ( 0.73)


75,4 (2.97) 37,3 (1.47) 1DR30-*-**-*

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-41
SRV-10 - Unloading/relief valve
Normally open or normally closed
57 L/min (15 USgpm) • 210 bar (3000 psi)

Normally closed version Operation Features


P This standard valve package is Normally closed and normally All components in the package
designed for pump unloading open options, tamper proof or are true cartridges and can
via solenoid valve activation adjustable relief options. Low be removed from the housing
and pump relief, when the power requirements, gauge without disturbing the plumbing.
solenoid valve is not activated port. Aluminum in-line type
and system pressure reaches housing, number of voltage
G T relief valve setting. and connector options.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Flow rating 57 L/min (15 USgpm)
P Internal leakage 80 cm³/min (5 in³/min) @ 210 bar (3000 psi)
Normally open version Reseat pressure 80% of crack pressure
P Typical vented ΔP 7 bar (100 psi) at rated flow
Coil specifications Power requirements: 18 watts
Coil duty: continuous from 85% to 110% of nominal voltage
(AC coils are internally rectified)
Temperature range -40° to 120° C (-40° to 248° F)
G T Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure drop (unloading) Pressure override


Solenoid actuated relief valve. Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
0 5 10 15 20 25 30 35 40 45 0 20 40 60 80 100
K 100 7
4000 280
Pressure Drop - bar
Pressure Drop - psi

Inlet pressure - bar


Inlet pressure - psi

75 210
5 3000

50 2000 140
3

25 1000 70
1
0 0
0 2 4 6 8 10 12 0 5 10 15 20 25 30
Flow - USgpm (105 SUS oil @ 120˚ F) Flow - USgpm (105 SUS oil @ 120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-42 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SRV-10 - Unloading/relief valve
Normally open or normally closed
57 L/min (15 USgpm) • 210 bar (3000 psi)

Model code SRV – 10 (V) – * – * – A ** – ** / *** – ** – 00

1 2 3 4 5 6 7 8 9 10 11

1  Function 5   Relief control 8   Relief Pressure range 10   Connector types


SRV - Solenoid actuated relief C - Cap NNote: Code based on pressure G - ISO 4400 DIN 43650
valve K - Knob in psi. connector
S - Screw 3 - 3-20 bar (50-300 psi) P - 1/2" NPT conduit
35 -17-240 bar (250-300 psi) W - Leadwire
2  Size
10 - 10 size 6   Valve housing material
A - Aluminum 9   Voltage rating 11   Special features
12D - 12 VDC 00 - None
3   Seal material
24D - 24 VDC (Only required if valve has special
Blank - Buna-N 115A - 115 VAC features, omitted if "00".)
V - Viton® 230A - 230 VAC
Viton is a registered trademark of
E.I. DuPont 7   Port size
Code P, T Gauge Housing number
4  Type 4G 1/2" BSPP 1/4" BSPP 02-178308
C - Normally closed
10T SAE 10 SAE 4 02-178309
O - Normally open

Composition chart
Cartridge Description Quantity

SV5-10-0-0-** 2 way/2 position N.O. poppet solenoid valve 1


SV1-10-C-0-** 2 way/2 position N.C. poppet solenoid valve 1
RV5-10-*-0-** Relief valve, pilot operated 1

Dimensions
mm (inch)
SV1-10-C-0-**
SV5-10-0-0-** NO
NC 69,5
8,8 (0.35) 57,9 (2.74)
(2.28)
19,0 (0.75)

P
53,8
68,3 (2.12) 19,0 19,0
(2.69) Ø 8,8 (0.75) G P ( 0.75)
(Ø 0.35)
thru 2 plcs.
75,4
(2.97)
K
T
8,8 ( 0.35)
33,0 (1.30)
78,7
(3.10)

RV5-10-*-0-**
55,8 (2.20) 25,4 (1.00)
81,7 (3.22) 50,0 (1.97)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-43
SRV-12 - Solenoid Vented Relief Valve
SRV-12
SRV-12 - Solenoid
- Solenoid
Normally open vented
or normally Vented
closedrelief Relief
valve Valve
Normally
100open
Normally open
L/min or normally
or (26 USgpm)
normally •closed
closed 210 bar (3000 psi)
100
100 L/min
L/min (26 (26 USgpm)
USgpm) • 210• bar
210(3000
bar (3000
psi) psi)

Normally
Normally Closed
closed Version
version Operation
Operation FeaturesFeatures
Normally
P Closed Version Operation Features
Normally
P
This standard valve
This standard valve package is package is
Normally closedclosed and normally
and normally All components
All components in the package
in the package
Thisdesigned
designed standard for
for pump pump
valve unloading
package
unloading is open open options,
Normally
options,closed
tamper tamper
and proof proof or
normally
or areAll are
true true cartridges
components
cartridges and canand
in the can
package
via solenoid
viadesigned
solenoid for pump
valve valve adjustable
open
activation adjustable
unloading
activation options, relief
tamper
relief options. options.
proof
Low orLowbe are be
trueremoved
removed from
cartridges
from the andthe
housingcanhousing
to control
via solenoid
to control remotelyremotely
valve ventablepower
activation
ventable power
adjustable requirements,
requirements, gaugegauge
relief options. Low without without
be removed disturbing
disturbingfrom
thethe the plumbing.
housing
plumbing.
relief and
to control
relief valve valve and system
remotely
system relief, relief,port.
ventable port.requirements,
power Aluminum
Aluminum in-linein-line
gauge
type type without disturbing the plumbing.
when
relief
when valve
the the
and
solenoidsolenoid
system valve
valve is not is not
relief, housing,housing,
port. Aluminum
number number
ofin-lineoftype
voltage voltage
when the solenoid valve is not andhousing,
activated.
activated. and connector
connectornumber
options. options.
of voltage
activated. and connector options.

Performance data Data


Performance
Performance
Ratings Data
and specifications
Ratings and Specifications
Ratings data
Performance andisSpecifications
typical
Performance data with fluid at
is typical 21,8fluid
with cST at
(105 SUS)
21,8 cSTand 49°C
(105 (120°F)
SUS) and 49°C (120°F)
Performance
Typical Typical data
application is typical
pressure (all
application with fluid at 21,8
ports) (all ports)
pressure cST (105 SUS) and 49°C (120°F) 210210 bar bar
(3000 psi) psi)
(3000
Typical
Flow Flow
rating application
rating pressure (all ports) 210
100
100 bar(26
L/min
L/min (3000
(26 psi)
USgpm)
USgpm)
G T Internal
Flow rating leakage 100 L/min (26 USgpm)
G
Internal leakage 3535 milliliters/min
milliliters/min @ bar
@ 280 280 bar
T Internal leakage 35 milliliters/min @in280 bar E
Reseat Reseat
pressure pressure Refer datasheet of 1VR100
Refer datasheet of 1VR100 in Section E Section
Reseat pressure
Typical vented ∆P Refer datasheet
Refer datasheetof 1VR100
of 1VR100 in Section
in SectionE E
Typical vented ∆P Refer datasheet of 1VR100 in Section E
Typical
Coilvented ∆P
specifications Refer datasheet of 1VR100
Power requirements:in Section E
16 watts
P Coil specifications Power requirements: 16 watts
Coil specifications Coil duty: Continuous fromPower 85% to 110%
requirements: of nominal16 voltage
watts
Normally
P openOpen
Normally version
Version
Coil duty: Continuous from 85% to 110% of nominal voltage
(AC coils
Coil duty: Continuous from 85%(AC to coils
110% areare internally
ofinternally
nominal rectified)
voltage
rectified)
Normally
P Open Version Temperature range (AC coils
-40° are internally
to 120° C (-40°rectified)
to 248° F)
Temperature range -40° to 120° C (-40° to 248° F)
P Temperature
Fluids range All general-40° to 120°
purpose C (-40°fluids
hydraulic to 248° F) as:
such
Fluids
Fluids All general
All general purpose
MIL-H-5606,
purpose hydraulic
hydraulic SAE fluids such 20,
10, SAE
fluids such as:
as:etc.
MIL-H-5606, SAE 10, SAE 20, etc.
MIL-H-5606, SAE 10, SAE 20, etc.

Pressuredrop
Pressure Dropcurves
Curves
Pressure Drop Curves
Pressure Drop Curves
Flow - L/min Flow - L/min
0 30 60 90 120 150 0 30 60 90 120 150
5800 400 432 30
5075 350 Vented pressure drop
360 25
4350 300
Pressure - bar
Pressure - psi

Pressure - psi

Pressure - bar
3625 288 20
250
2900 200 216 15
G T
G T 2175 150 144 10
1450 100
72 5
0725 50
P 0 0 0 0
P
Description 0 8 16 24 32 40 0 8 16 24 32 40
Description
Description Flow - US gpm Flow - US gpm
K Solenoid
Solenoid actuated
actuated vented
vented relief relief
valve.
Solenoid actuated vented relief
K valve.
K valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
K-270.A.B are critical request
Where measurements EATON certified drawings.
Screw-In We reserve
Cartridge the right
Valves to change specifications
E-VLSC-MC001-E2 Maywithout
2015 notice.
K-270.A
.B EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015
K-44 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SRV-12 - Solenoid Vented Relief Valve
SRV-12 - Solenoid vented relief valve
Normally open or normally closed Normally open or normally closed
100 L/min (26 USgpm) • 210 bar (3000 psi) 100 L/min (26 USgpm) • 210 bar (3000 psi)

Model code SRV – 12 (SV) – * – * – A ** – ** / *** – ** – 00


Model Code SRV – 12 (SV) – * – * – A ** – ** / *** – ** – 00
1 2 3 4 5 6 7 8 9 10 11
1 2 3 4 5 6 7 8 9 10 11

1  Function 5   Relief control 8   Relief pressure range 10   Connector types


1 Function 5 Relief Control 8 Relief Pressure Range 10 Connector Types
SRV - Solenoid actuated P - Leakproof Screw NNote: Code based on pressure GS - ISO 4400 DIN 43650
SRV -valve
Solenoid actuated P - Leakproof Screw Adjust- Note: Code based on pressure
ventable relief Adjustments in psi. connector GS - ISO 4400 DIN 43650
ventable relief valve ments in psi. PS - 1/2" NPT conduit connector
G - Temper Proof Cap 20 - 10-210 bar (145-3000 psi)
2  Size G - Temper Proof Cap 20 - 10-210 bar (145-3000 psi)
WS - Leadwire PS - 1/2" NPT conduit
6 WS - Leadwire
12 - 12 size 2 Size   Valve housing material
6 Valve Housing 9 Material
  Voltage rating
12 - 12 size A - Aluminum 11   Special features
3   Seal material A - Aluminum 12D - 12 VDC 9 Voltage Rating 11 Special Features
24D - 24 VDC 12D - 12 VDC 00 - None 00 - None
S- Nitrile (for use 3withSealmostMaterial 120A - 120 VAC24D - 24 VDC (Only required if valve(Only
has required
special if valve has special
industrial hydraulic oils) 240A - 240 VAC120A - 120 VAC features, omitted if "00".)
S - Nitrile (for use with most features, omitted if "00")
V - Viton® (for highindustrial hydraulic oils) 240A - 240 VAC
temperatures and most®
SV - Viton (for high7 tempera-
  Port size
special fluid applications) 7 Port Size
tures and most special Code fluid P, T Gauge Housing number
Viton is a registeredapplications)
trademark of Code P, T Gauge Housing
E.I. DuPont 6W
Viton is a registered trademark of E.I. 3/4"6WBSPP 1/4" BSPP
3/4" BSPP
6030455-001
1/4" BSPP 6030455-001
DuPont 12T SAE 12 SAE 4 6030455-002
4  Type 12T SAE 12 SAE 4 6030455-002
C - Normally closed
4 Type Composition chart
O - Normally open Composition Chart
C - Normally closedCartridge
Cartridge Description Description Quantity Quantity
O - Normally open
SV5-8-0-0-** 2 way/2 position N.O. poppet solenoid valve 1
SV5-8-0-0-** 2 way/2 position N.O. poppet solenoid valve 1
SV5-8-C-0-** SV5-8-C-0-**2 way/2 position N.C. poppet2solenoid valve N.C.
way/2 position 1 poppet solenoid valve 1
1VR100***-P*-** * 1VR100***-P*-**
Vented
* relief valve Vented relief valve1 1
SV5-8-0-0-**/
SV5-8-C-0-**/
Dimensions Dimensions SV5-8-0-0P-0-00(No Coil)
mm (inch)
mm (inch)

1VR100***-P*-** *

53
[2.09]

50.5
46.4
[1.99] “T”
[1.83]
53 81.8
[2.09]
“P”
[3.22] 100.8
[3.97]
K

“G”

25.4 25.4
[1.00] [1.00]
50
75.4
[1.97]
[2.97]
M10x1.5-6Hx.62 DP.
MTG Holes for BSPP Ports Option
3/8 - 16 UNC-2B X.62 DP.
MTG Holes for SAE # 12 Ports Option

Where request
Where measurements are critical measurements
certifiedare critical request
drawings. certified
We reserve drawings.
the right We reserve
to change the rightwithout
specifications to change specifications without notic
notice.

EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 K-271.A


.B
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-45
SRV-16 - Solenoid vented relief valve
Normally open or normally closed
225 L/min (60 USgpm) • 210 bar (3000 psi)

Normally closed version Operation Features


P
This standard valve package is Normally closed and normally All components in the package
designed for pump unloading open options, tamper proof or are true cartridges and can
via solenoid valve activation adjustable relief options. Low be removed from the housing
and pump relief, when the power requirements, gauge without disturbing the plumbing.
solenoid valve is not activated port. Aluminum in-line type
and system pressure reaches housing, number of voltage
relief valve setting. and connector options.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Flow rating 225 L/min (60 USgpm)
Internal leakage 160 L/min (10 in³/min) @ 210 bar (3000 psi)
G Reseat pressure 80% of crack pressure
Typical vented ΔP 8 bar (120 psi) at rated flow
Coil specifications 16 watts
P T Power requirements: Continuous from 85% to 110% of nominal voltage
Coil duty: (AC coils are internally rectified)
Temperature range -40° to 120° C (-40° to 248° F)
Normally open version Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
P

Pressure drop (unload) Pressure override

Flow - L/min (21,8 cSt oil @ 49˚ C) ? Flow - L/min (21,8 cSt oil @ 49˚ C)
0 40 80 120 160 200 0 40 80 120 160 200
140 10 200
3000
120
Pressure drop - psi

8
150
Pressure drop - bar

Pressure - bar
100
Pressure - psi

6 2000
80
100
60 4
1000
40 50
2
20
K G 0 0 0
0 0 10 20 30 40 50 60
10 20 30 40 50 60
Fl - USgpm (105 SUS oil @ 120˚ F)

P T

Description
Solenoid actuated relief valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-46 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SRV-16 - Solenoid vented relief valve
Normally open or normally closed
225 L/min (60 USgpm) • 210 bar (3000 psi)

Model code SRV – 16 (V) – * – * – A ** – ** / *** – ** – 00

1 2 3 4 5 6 7 8 9 10 11

1  Function 5   Relief control 8   Relief Pressure range 10   Connector types


SRV - Solenoid actuated C - Cap NNote: Code based on pressure GS -ISO 4400 DIN 43650
relief valve K - Knob in psi. connector
S - Screw 15 - 3-100 bar (50-1500 psi) PS - 1/2" NPT conduit
30 - 70-210 bar (1000-3000 psi) WS - Lead wire
2  Size
16 - 16 size 6   Valve housing material
A - Aluminum 9   Voltage rating 11   Special features
12D - 12 VDC 00 - None
3   Seal material
24D - 24 VDC (Only required if valve has special
Blank - Buna-N 120A - 125 VAC features, omitted if "00".)
V - Viton® 240A - 240 VAC
Viton is a registered trademark of
E.I. DuPont 7   Port size
Code P, T Gauge
4  Type
8G 1" BSPP 1/4" BSPP
C - Normally closed
O - Normally open 16T SAE 16 SAE 4
12T SAE 12 SAE 4

Composition chart
Cartridge Description Quantity

SV4-8-0-0-** 2 way/2 position N.O. poppet solenoid valve 1


SV4-8-C-0-0-** 2 way/2 position N.C. poppet solenoid valve 1
RV8-8-*-0-** Relief valve 1
DPS2-16-V-F-0-80 Differential pressure sensing valve 1

Dimensions
mm (inch)
RV-8-8-*-0-**
DPS2-16-F-0-80
72,3
(2.85)

Ø 8,7
27,9
(1.10) (Ø 0.34) 51,3 K
thru 2 plcs. (2.02)
83,8 T
(3.30) 83,8
100,8 (3.30)
(3.97) P 113,5
G (4.47)
P

30,4 (1.20) 31,4 (1.24)


96,5 (3.80) 62,7 (2.47)
138,9 (5.47)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-47
SRV-20 - Solenoid vented relief valve
Normally open or normally closed
300 L/min (80 USgpm) • 210 bar (3000 psi)

Normally closed version Operation Features


P This standard valve package is Normally closed and normally All components in the package
designed for pump unloading open options, tamper proof or are true cartridges and can
via solenoid valve activation adjustable relief options. Low be removed from the housing
and pump relief, when the power requirements, gauge without disturbing the plumbing.
solenoid valve is not activated port. Aluminum in-line type
and system pressure reaches housing, number of voltage
relief valve setting. and connector options.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Flow rating 300 L/min (80 USgpm)
Internal leakage 160 cm³/min (10 in³/min) @ 210 bar (3000 psi)
Reseat pressure 80% of crack pressure
Typical vented ΔP 9 bar (135 psi) at rated flow
G
Coil specifications Power requirements: 16 watts
Coil duty: Continuous from 85% to 110% of nominal voltage
(AC coils are internally rectified)
Temperature range -40° to 120° C (-40° to 248° F)
P T
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Normally open version
P Pressure drop (unloading) Pressure override
Flow - L/min (21,8 cSt oil @ 49˚ C) Flow - L/min (21,8 cSt oil @ 49˚ C)
0 40 80 120 160 200 240 280 320 360 80 160 240
250 18 3000 200
16
Pressure drop - psi

Pressure drop - bar

200 14 150

Pressure - bar
Pressure - psi

12 2000
150 10 100
8
100 1000
6 50
50 4
2 0
0 0 0 20 40 60 80
0 10 20 30 40 50 60 70 80 90 100
Flow - USgpm (105 SUS oil @ 120˚ F)
Flow - USgpm (105 SUS oil @ 120˚ F)
P/V models

K G

P T

Description
Solenoid actuated relief valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-48 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SRV-20 - Solenoid vented relief valve
Normally open or normally closed
300 L/min (80 USgpm) • 210 bar (3000 psi)

Model code SRV – 20 (V) – * – * – A ** – ** / *** – ** – 00

1 2 3 4 5 6 7 8 9 10 11

1  Function 5   Relief control 8   Relief Pressure range 10   Connector types


SRV - Solenoid actuated relief C - Cap NNote: Code based on pressure GS - ISO 4400 DIN 43650
valve K - Knob in psi. connector
S - Screw 15 - 3-100 bar (50-1500 psi) PS - 1/2" NPT conduit
2  Size 30 - 70-210 bar (1000-3000 psi) WS - Leadwire

20 - 20 size 6   Valve housing material


A - Aluminum 9   Voltage rating 11   Special features

3   Seal material 12D - 12 VDC 00 - None


24D - 24 VDC (Only required if valve has special
Blank - Buna-N 120A - 125 VAC features, omitted if "00".)
V - Viton® 240A - 240 VAC
Viton is a registered trademark of
E.I. DuPont  
7   Port size

4  Type Code P, T Gauge Housing

C - Normally closed 12G 1 1/4" BSPP 1/4" BSPP 02-178312


O - Normally open 20T SAE 20 SAE 4 02-178313

Composition chart
Cartridge Description Quantity

SV4-8-0-0-** 2 way/2 position N.O. poppet solenoid valve 1


SV4-8-C-0-** 2 way/2 position N.C. poppet solenoid valve 1
RV8-8-*-0-** Relief valve 1
DPS2-20-V-F-0-80 Differential pressure sensing valve 1

Dimensions SV4-8-C-0-** NC
RV-8-8-*-0-** SV4-8-0-0-** NO
mm (inch)
DPS2-20-V -F-0-80
72,6
(2.86)

76,2 Ø 10,7 50,8


83,8
(3.00) (Ø 0.42) (2.00) T
106,6
K
thru 2 plcs.
(3.30) P (4.20)
106,6 138,9
(4.20) (5.47)
G
P

33,0 (1.30) 31,4 (1.24)


60,9 (2.40) 62,7 (2.47)
137,1 (5.40)
151,6 (5.97)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-49
CRV-10 - Relief valve
Cross port
76 L/min (20 USgpm) • 17-210 bar (250-3000 psi)

Operation Features
This standard valve package is Tamper proof and adjustable All components in the package
used to provide pressure relief relief options. Aluminum are true cartridges and can
for bi-directional motors and in-line type housing. be removed from the housing
cylinders. without disturbing the plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 17-210 bar (250-3000 psi)
Flow rating 76 L/min (20 USgpm)
Reseat pressure 90% of crack pressure
Temperature range -40° to 120° C (-40° to 248° F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description Pressure override


Cross port relief valve.
Flow - L/min (21,8 cSt oil @ 49˚ C)
0 20 40 60
3000 200

150

Pressure - bar
Pressure - psi

2000

100

1000
50

0 0
0 5 10 15 20
Flow - USgpm (105 SUS oil @ 120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-50 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
CRV-10 - Relief valve
Cross port
76 L/min (20 USgpm) • 17-210 bar (250-3000 psi)

Model code CRV – 10 (V) – * – A ** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1  Function 4   Relief control 6   Port size


CRV - Cross-port relief valve C - Cap Code Port size Housing number
K - Knob
S - Screw 3G 3/8" BSPP 02-178476
2  Size 8T SAE 8 889185
10 - 10 size
5   Valve housing material
7   Pressure Range 9   Special Features
A - Aluminum
3   Seal material NNote: Code based on pressure 00 - None
Blank - Buna-N in psi.
(Only required if valve has special
V - Viton® 6 - 6-40 bar (100-600 psi) features, omitted if "00".)
Viton is a registered trademark of 36 - 40-250 bar (600-3600 psi)
E.I. DuPont

8   Pressure Setting -
user requested in 50 PSI steps
Example:
10 - 1000 psi
10.5 - 1050 psi

Composition chart
Cartridge Description Quantity

RV3A-10-*-0-** Relief valve 2

Dimensions
mm (inch)

76,2 RV3A-10-*-0-**
(3.0)
41,3 (1.63)
20,6 (0.81) SAE 8
(2 thru ports)

63,5 50,8
(2.5) (2.0)

K
Ø 8,73 (0.343)
thru 2 plcs.
SAE 8 size both sides
79,4
Thru 2 plcs., each tapped
(3.13)

"C" Adjustment
85,7 (3.38) 19,05 (0.75) hex.
34,9 (1,37)
106,4 (4.18)
127,0 (5.0)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-51
CRV-16 - Relief valve
Cross port
303 L/mim (80 USgpm) • 17-172 bar (250-2500 psi)

Operation Features
This standard valve package is Tamper proof and adjustable All components in the package
used to provide pressure relief relief options. Aluminum are true cartridges and can
for bi-directional motors and in-line type housing. be removed from the housing
cylinders. without disturbing the plumbing.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 17-172 bar (250-2500 psi)
Flow rating 300 L/min (80 USgpm)
Reseat pressure 90% of crack pressure
Temperature range -40° to 120° C (-40° to 248° F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.

Description
Cross port relief valve. Pressure override
Flow - L/min (21,8 cSt oil @ 49˚ C)
0 50 100 150 200 250 300
3000 200

150

Pressure - bar
Pressure - psi

2000

100

1000
50

0 0
0 20 40 60 80
Flow - USgpm (105 SUS oil @ 120˚ F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-52 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
CRV-16 - Relief valve
Cross port
303 L/mim (80 USgpm) • 17-172 bar (250-2500 psi)

Model code CRV – 16 (V) – * – A *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1  Function 4   Relief control 6   Port size


CRV - Cross-port relief valve C - Cap Code Port size Housing number
K - Knob
S - Screw 8G 1" BSPP 02-178477
2  Size 16T SAE 16 889189
16 - 16 size
5   Valve housing material
7   Pressure range 9   Special features
A - Aluminum
3   Seal material NNote: Code based on pressure 00 - None
Blank - Buna-N in psi.
(Only required if valve has special
V - Viton® 25 - 17-175 bar (250-2500 psi) features, omitted if "00".)
Viton is a registered trademark of E.I.
DuPont
8   Pressure setting -
user requested in 50 PSI steps
Example:
10 - 1000 psi
10.5 - 1050 psi

Composition chart
Cartridge Description Quantity

RV3A-16-*-0-** Relief valve 2

Dimensions
mm (inch)

38,1 (1.5) hex (both cartridges)


Torque 109-122 Nm (80-90 lbf ft)
99,2 RV 3A-16(V)-*-0-25
(3.91)
66,7 (2.63)
31,7 (1.25) SAE 16
(2 thru ports)

88,9 69,9
(3.50) (2.75)

K
Ø 8,73 (0.343)
thru 2 plcs.
SAE 16 size both sides
57,1 Thru 2 plcs., each tapped
(3.91)

"C" Adjustment
19,05 (0.75) hex.
136,6 (5.38) 50,8 (2.00)
171,5 (6.75)
203,2 (8.00)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-53
RGV-30 - Regenerative valve
Pressure sensitive
30 L/min (8 USgpm) • 210 bar (3000 psi)

Operation Features
This standard valve package When applying pressure Automatic kick out of
provides means for fast sensitive regenerative valves regenerative operation
extension of a cylinder consider the following: Rod to made via load pressure
at low pressure without diameter ratio. The pressure sensing. Tamper proof and
additional pump flow. This required to move a cylinder. adjustable pressure setting
package diverts rod end flow Losses due to high flows options. Provides a smooth
to the head end in order to and seal friction may prevent transition and decrease of
accelerate the load. When the a circuit from staying in the regenerative flow through
load induced pressure reaches regeneration. use of a counterbalance
a predetermined level, the valve. Aluminum in-line type
valve closes off. Rod end oil is housing.
V C automatically diverted to tank
and the full pump pressure is
applied, allowing maximum
force to develop at lower
speed.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regenerative flow
Regeneration diminishes progressively above setting of 1CE30 30 L/min (8 USgpm)
Temperature range -40° to 120° C (-40° to 248° F)
CH NNotes: Regeneration circuits apply only to single rod cylinders in extension direction.

Description Pressure drop


Pressure sensitive regenerative Flow - L/min
valve package. 5 10 15 20 25 30 35 40 45 50 55
A - Port CR to CH 300 20
280
B - Port VR to CR 260
17
240
220
Pressure - bar
Pressure - psi

200 14
180
160 11
140
120 9
K 100
80
A 7
5
60 B
40 3
20 1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Flow - USgpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-54 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
RGV-30 - Regenerative valve
Pressure sensitive
30 L/min (8 USgpm) • 210 bar (3000 psi)

Model code RGV – 30 (V) – * – A *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1  Function 4   Relief control 6   Port size


RGV - Pressure sensitive F - Screw adjustment Code Port size Housing number
regeneration valve N - Fixed - State pressure 4G 1/2" BSPP 6029951-001
setting required
10T SAE 10 6029950-001
2  Size
30 - 10 size 5   Valve housing material
7   Pressure range* 8   Pressure setting -
A - Aluminum user requested in 50 PSI steps
NNote: Code based on pressure
3   Seal material in psi. Example:
Blank - Buna-N 20 - 70 - 210 bar. std. setting 10 - 1000 psi
V - Viton® 100 bar 10.5 - 1050 psi
Viton is a registered trademark of *System pressure is limited to 210 bar
E.I. DuPont (3000 psi)
9   Special features
00 - None
Composition chart (Only required if valve has special
features, omitted if "00".)
Cartridge Description Quantity

1CE30-F-20-S-5 Counterbalance valve 1


DPS2-10-S-F-0-80 Differential pressure sensing 1
566395 Sense check kit 1

Application notes Regenerative Flow Db² - Dr²


Formulas to calculate flow in regeneration circuits are: (flow out rod end) = X Pump Flow
(where Db = Bore Diameter and Dr = Rod Diameter) Dr²
Retraction Flow Db²
Combined Flow Db² (flow out of the bind = X Pump Flow
(pump flow plus = X Pump Flow end during retraction) Db² - Dr²
regenerative flow) Dr²

Dimensions
mm (inch)

NNote: This valve package should


not be used as a load holding or
load lowering control valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-55
RGV-90 - Regenerative valve
Pressure sensitive
90 L/min (23 USgpm) • 210 bar (3000 psi)

Operation Features
This standard valve package When applying pressure Automatic kick out of
provides means for fast sensitive regenerative valves regenerative operation
extension of a cylinder consider the following: Rod to made via load pressure
at low pressure without diameter ratio. The pressure sensing. Tamper proof and
additional pump flow. This required to move a cylinder. adjustable pressure setting
package diverts rod end flow Losses due to high flows options. Provides a smooth
to the head end in order to and seal friction may prevent transition and decrease of
accelerate the load. When the a circuit from staying in the regenerative flow through
load induced pressure reaches regeneration. use of a counterbalance
a predetermined level, the valve. Aluminum in-line type
valve closes off. Rod end oil is housing.
V C automatically diverted to tank
and the full pump pressure is
applied, allowing maximum
force to develop at lower
speed.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cst (105 sus) and 49°c (120°f)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regenerative flow
Regeneration diminishes progressively above setting of 1CE90 90 L/min (23 USgpm)
CH Temperature range -40° to 102° C (-40° to 248° F)
NNotes: Regeneration circuits apply only to single rod cylinders in extension direction.

Description Pressure drop


Pressure sensitive regenerative Flow - L/min
valve package. 10 20 30 40 50 60 70 80 90 100 110
A - Port CR to CH 500 35
450 30
B - Port VR to CR
400
25
350
Pressure - psi

Pressure - bar

300 20
250
15
200
K 150 10
100 A
5
50
B
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Flow - USgpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-56 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
RGV-90 - Regenerative valve
Pressure sensitive
90 L/min (23 USgpm) • 210 bar (3000 psi)

Model code RGV – 90 (V) – * A *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1  Function 4   Relief control 6   Port size


RGV - Pressure sensitive F - Screw adjustment Code Port size Housing number
regeneration valve N - Fixed - State pressure
setting required 6G 3/4" BSPP 6029914-001
12T SAE 12 6029909-001
2  Size
90 - 12 size 5   Valve housing material 7   Pressure range* 8   Pressure setting -
A - Aluminum NNote: Code based on pressure user requested in 50 PSI
3   Seal material in psi. steps Example:

Blank - Buna-N 20 - 70 - 225 bar. std. setting 10 - 1000 psi


V - Viton® 100 bar 10.5 - 1050 psi
Viton is a registered trademark of E.I. *System pressure is limited to 210 bar
DuPont (3000 psi)
9   Special features
00 - None
Composition chart (Only required if valve has special
features, omitted if "00".)
Cartridge Description Quantity

1CE90-F-20-*-4 Counterbalance valve 1


DPS2-16-S-F-0-80 Differential pressure sensing 1
566395 Sense check kit 1

Application Notes
Formulas to calculate flow in regeneration circuits are: Regenerative Flow Db² - Dr²
(where Db = Bore Diameter and Dr = Rod Diameter) (flow out rod end) = X Pump Flow
Dr²
Combined Flow Db²
(pump flow plus = X Pump Flow Retraction Flow Db²
regenerative flow) Dr² (flow out of the bind = X Pump Flow
end during retraction) Db² - Dr²

Dimensions
mm (inch)

NNotes: This valve package should


not be used as a load holding or
load lowering control valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-57
RLV-30 - Regenerative valve
With load locking
30 L/min (8 USgpm) • 210 bar (3000 psi)

Operation Features
This standard valve package When applying pressure Automatic kick out of
provides means for fast sensitive regenerative valves regenerative operation
extension of a cylinder consider the following: Rod to made via load pressure
at low pressure without diameter ratio. The pressure sensing. Tamper proof and
additional pump flow. This required to move a cylinder. adjustable pressure setting
package diverts rod end flow Losses due to high flows options. Provides a smooth
to the head end in order to and seal friction may prevent transition and decrease of the
accelerate the load. When the a circuit from staying in regenerative flow through use
load induced pressure reaches regeneration. of a counterbalance valve.
a predetermined level, the Provides manual override on
V
valve closes off. Rod end oil is POC cartridge to lower the
C
automatically diverted to tank load in the event of power
and the full pump pressure is loss. Aluminum in-line type
applied, allowing maximum housing.
force to develop at lower
speed.

Performance data
Ratings and specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regenerative flow
Regeneration diminishes progressively above setting of 1CE30 30 L/min (8 USgpm)
VH CH Temperature range -40° to 120° C (-40° to 248° F)

NNotes: Regeneration circuits apply only to single rod cylinders in extension direction.

Description Pressure drop


Pressure sensitive Flow - L/min
regenerative valve package 0 5 10 15 20 25 30 35 40
with load locking. A - Port CR to CH 250 17
225
B - Port VR to CR
200 14
C - Port VH to CH
175
Pressure - psi

Pressure - bar

11
150
125 9
100 7
K 75
A
5
50 3
B
25
C 1
0 0
0 1 2 3 4 5 6 7 8 9 10
Flow - USgpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-58 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
RLV-30 - Regenerative valve
With load locking
30 L/min (8 USgpm) • 210 bar (3000 psi)

Model code RLV – 30 (V) – * – A *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1  Function 4   Relief control 6   Port size


RLV - Pressure sensitive F - Screw adjustment Code Port size Housing number
regeneration valve with load N - Fixed - Stare pressure
holding check valve. setting required 4G 1/2" BSPP 6029965-001
10T SAE 10 6029964-001
2  Size 5   Valve housing material
10 - 10 size A - Aluminum 7   Pressure range* 8   Pressure setting -
NNote: Code based on pressure user requested in 50 PSI
in psi. steps Example:
3   Seal material
20 - 70 - 210 bar. std. setting 10 - 1000 psi
Blank - Buna-N 100 bar 10.5 - 1050 psi
V - Viton®
*System pressure is limited to 210 bar
Viton is a registered trademark of E.I. (3000 psi)
DuPont 9   Special features
00 - None
(Only required if valve has special
Composition chart features, omitted if "00".)
Cartridge Description Quantity

1CE30-F-*20-*-4 Counterbalance valve 1


DPS2-10-S-F-0-80 Differential pressure sensing 1
4CK30-1S3 Pilot operated check valve 1
566395 Sense check kit 1

Application notes Regenerative Flow Db² - Dr²


Formulas to calculate flow in regeneration circuits are: (flow out rod end) = X Pump Flow
(where Db = Bore Diameter and Dr = Rod Diameter) Dr²
Retraction Flow Db²
Combined Flow Db² (flow out of the bind = X Pump Flow
(pump flow plus = X Pump Flow end during retraction) Db² - Dr²
regenerative flow) Dr²

Dimensions
mm (inch)

NNotes: This valve package should


not be used as a load holding or
load lowering control valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-59
RLV-90 - Regenerative valve
With load locking
90 L/min (23 USgpm) • 210 bar (3000 psi)

Operation Features
This standard valve package When applying pressure Automatic kick out of
provides means for fast sensitive regenerative valves regenerative operation
extension of a cylinder consider the following: Rod to made via load pressure
at low pressure without diameter ratio. The pressure sensing. Tamper proof and
additional pump flow. This required to move a cylinder. adjustable pressure setting
package diverts rod end flow Losses due to high flows options. Provides a smooth
to the head end in order to and seal friction may prevent transition and decrease of the
accelerate the load. When the a circuit from staying in regenerative flow through use
load induced pressure reaches regeneration. of a counterbalance valve.
a predetermined level, the Provides manual override on
valve closes off. Rod end oil is POC cartridge to lower the
V C
automatically diverted to tank load in the event of power
and the full pump pressure is loss. Aluminum in-line type
applied, allowing maximum housing.
force to develop at lower
speed.

Performance data
Ratings and specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Maximum regenerative flow 90 L/min (23 USgpm)
Regeneration diminishes progressively above setting of 1CE90
VH CH Temperature range -40° to 120° C (-40° to 248° F)
NNotes: Regeneration circuits apply only to single rod cylinders in extension direction.

Description Pressure drop


Flow - L/min
Pressure sensitive
regenerative valve package 5 10 15 20 25 30 35 40 45 50 55
A - Port CR to CH 300 20
with load locking. 280
B - Port VR to CR 260
240 17
C - Port VH to CH 220
200 14
Pressure - psi

Pressure - bar

180
K 160
140
11

120 9
A
100 7
80 5
60 B
40 3
20 C 1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Flow - USgpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-60 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
RLV-90 - Regenerative valve
With load locking
114 L/min (30 USgpm) • 210 bar (3000 psi)

Model code RLV – 90 (V) – * – A *** – ** / ** – 00

1 2 3 4 5 6 7 8 9

1 Function 4 Relief control 6 Port size


RLV - Pressure sensitive F - Screw adjustment Code Port Size Housing number
regeneration valve w/ load N - Fixed - Stare pressure set-
6G 3/4" BSPP 02-178936
holding check valve ting required
12T SAE 12 02-178935
2 Size 5 Valve housing material
90 - 12 size A - Aluminum 7 Pressure range* 8 Pressure setting - user
Note: Code based on pressure requested in 50 PSI steps
3 Seal material in psi. Example:
20 - 70 - 225 bar. std setting 10 - 1000 psi
Blank - Buna-N 100 bar 10.5 - 1050 psi
V- Viton® *System pressure is limited to
Viton is a registered trademark of
E.I. DuPont 210 bar (3000 psi) 9 Special features
00 - None
(Only required if valve has special
Composition chart features, omitted if "00".)
Cartridge Description Quantity
1CE90-F-20-*-4 Counterbalance valve 1
DPS2-16-S-F-0-80 Differential pressure sensing 1
POC1-12-S-0-005 Pilot operated check valve 1
566395 Sense check kit 1

Application Notes
Formulas to calculate flow in regeneration circuits are: Regenerative Flow Db² - Dr²
(where Db = Bore Diameter and Dr = Rod Diameter) (flow out rod end) = X Pump Flow
Dr²
Combined Flow Db²
(pump flow plus = X Pump Flow Retraction Flow Db²
regenerative flow) Dr² (flow out of the bind = X Pump Flow
end during retraction) Db² - Dr²

Dimensions
mm (inch)
K

NNotes: This valve package should


not be used as a load holding or
load lowering control valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-61
SCR-1 - Cross port relief
With shuttle and solenoid vent
Up to 114 L/min (30 USgpm) • 210 bar (3000 psi)

Normally Open Version Operation Features


V1 D V2 This standard valve package Normally closed and normally All components in the package
is used to provide pressure open options. Tamper proof are true cartridges and can
line relief for bi-directional or adjustable relief options, be removed from the housing
motors and cylinders. With gauge port. Low power without disturbing the plumbing.
the addition of a remotely requirements, number of
controlled shuttle valve, voltages and connectors
G1 G2 allowance is made for options. Aluminum in line type
motor slip or cylinder dump housing.
conditions.

Performance data
Ratings and specifications
Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 210 bar (3000 psi)
Flow rating 114 L/min (30 USgpm)
Reseat pressure 90% of crack pressure
Coil specifications Power requirements: 16 watts Magnet wire – UL class N rated (200º C)
Coil duty: Continuous from 85% to 110% of nominal voltage
(AC coils are internally rectified)
Temperature range -40° to 120° C (-40° to 248° F)
V1 V2 NNotes: Regeneration circuits apply only to single rod cylinders in extension direction.

Normally Closed Version


V1 D V2

G1 G2

Pressure drop Flow - L/min (21,8 cSt oil @ 49˚ C)


20 40 60 80 100 120
Port 1 - 2 differential pressure - psid

A - 30 - pressure range 4000 275


code
A
B - 15 - pressure range 3000 210
code

2000 140

Bar
B
1000 70
V1 V2
K 0 0 5 10 15 20 25 30
0

Flow - USgpm (105 SUS oil @ 120˚ F)


Description
Cross port relief with shuttle
and solenoid vent.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-62 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
SCR-1 - Cross port relief
With shuttle and solenoid vent
Up to 114 L/min (30 USgpm) • 210 bar (3000 psi)

Model code SCR – 1 (V) – * – * – A ** ** / ** – *** ** – 00

1 2 3 4 5 6 7 8 9 10 11 12

1 Function 5 Relief control 10 Voltage rating


SCR - Solenoid actuated C - Cap 12D - 12 VDC
crossover relief valve with K - Knob 24D - 24 VDC
shuttle S - Screw 120A - 120 VAC
240A - 240 VAC
2 Size 6 Valve housing material
1 - 114 L/min (30 USgpm) A - Aluminum 11 Connector types
GS - ISO 4400 DIN 43650
3 Seal material 7 Port size connector
PS - 1/2" NPT conduit
Blank - Buna-N Code V1, V2 Gauge Drain Housing number
WS - Leadwire
V- Viton® 6G 3/4" BSPP 1/4" BSPP 3/8" BSPP 02-178938
Viton is a registered trademark of E.I.
12T SAE 12 SAE 4 SAE 6 02-178937 12 Special features
DuPont
00 - None
8 Pressure range* 9 Pressure setting -
4 Type (Only required if valve has special
Note: Code based on pressure user requested in 50 psi steps features, omitted if "00".)
C - Normally closed
in psi. Example:
O - Normally open
15 - 5-100 bar (75-1500 psi)
30 - 10-210 bar (150-3000 psi) 10 - 1000 psi
*System pressure is limited 10.5 - 1050 psi
to 210 bar (3000 psi)

Composition chart
Cartridge Description Quantity
VRV11-12-*-0-**/ Ventable relief valve 2
DSV2-8-B-0 Shuttle valve 1
SV5-8-C-0-** Solenoid valve, N.C. 1
SV5-8-O-0-** Solenoid valve, N.O. 1

1VR100-*-**-*
Dimensions (2 req'd)
mm (inch)
Ø 10,7 (Ø 0.422)
72,6 dia. thru 2 plcs.
(2.86)
12,7 (0.50) DSV2-8-B-0

V2 42,1 42,1
(1.66) (1.66) V2 G2 V2
67,8 84,0
126,2
DR (2.67) 91,4
91,4 (3.60) 113,5
(3.31) K
(4.97) (3.60) (4.47) V1
G1

V1
V1

72.6 SV5-8-C-0-**** (N.C.)


(2.86) SV5-8-O-0-**** (N.O.)
12,7 (0.50)
41,3 (1.70)
22,0 (0.87)
50,5 (1.99) 83,0 (3.27)
69,0 (2.72) 113,5 (4.47)
126,2 (4.97)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-63
1UL255 - Unloading valve
Two pump
Up to 200 L/min (40 USgpm) • 350 bar (5000 psi)

Operation Features
P2 SYSTEM
Pump inlet to P1 and P2 is (See graph for the pressure This is a self contained system
combined to give maximum drop of the dumped flow). The including two replaceable
flow at low pressure. When system relief valve provides cartridges with full adjustment
the load pressure increases to protection by limiting the through their respective
the valve setting the high flow maximum pressure in the ranges. Hardened working
(low pressure) pump is system line. components give long,
T bypassed from P1 to tank trouble-free life and single
allowing nearly all system body reduces plumbing to a
power to be used for the high minimum.
pressure pump.

P1

Performance data
Ratings and specifications
Performance data is typical with fluid at 32 cST (150 SUS)
Rated flow low flow/high pressure (P2 150 L/min (40 USgpm)
high flow/low pressure (P1)) 200 L/min (52 USgpm)
Max setting 350 bar (5000 psi)
Cartridge material Working parts hardened & ground steel
External surface zinc plated
Body material Standard - steel
Mounting position Unrestricted
Weight 3.15 kg (6.93 lbs)
Seal kit number SK671 (Nitrile) SK671V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194° F)
Nominal viscosity range 5 to 500 cSt
Viton is a registered trademark of E.I. DuPont

Description Pressure drop


Two-pump unloader valves Flow - L/min
are used in systems with
0 40 80 120 160 200 240
combinations of two (or more) 20.7
300
pumps to give high flow at low
pressure and high pressure
at low flow. The valves
bypass the flow from the low 250 17.2
pressure pump(s) to tank at a
pre-set pressure. This allows
pump selection to give, for
example, rapid advance and 200 13.8
high power compaction with
the most economic usage
Pressure - bar
Pressure - psi

K of system components and


energy requirements. 150 10.3
P1 - T

100 6.9

50 3.5

0 10 20 30 40 50 60
Flow - US gpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-64 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1UL255 - Unloading valve
Up to 200 L/min (40 USgpm) • 350 bar (5000 psi)

Model code 1UL255 – P 6W-4W – 20 / 35 S

1 2 3 4 5 6

1 Basic code 4 
Adjustable low 5 
Adjustable high 6 Seals
pressure range pressure range S - Nitrile (For use with
1UL255 - Complete Valve
Note: Code based on pressure Note: Code based on pressure most industrial hydraulic
in bar. in bar. oils)
2 Adjustment means
20 - 30-210 bar. 17 - 35-175 bar. SV - Viton (For high
P - Leakproof Screw Std setting 100 bar Std setting 105 bar temperature and most
Adjustment 35 - 150-350 bar. 28 - 75-285 bar. special fluid applications)
Std setting 200 bar Std setting 175 bar
3 Port sizes - 35 - 114-350 bar.
Std setting 280 bar
Code System PI & T P2 Housing number (steel)
6W-4W 3/4" BSPP 1/2" BSPP BXP24051-6W-4W-S-377

130
Dimensions Low Pressure
(5.12)
Unloading Cartridge 58
mm (inch) 1PUL200-P-20-S-JL (2.28)

Complete Valve
T
Basic Code: 1UL255 P1

25.4
(1.0)

179 MAX
(7.05)
50.8
(2.0)
25.4 10 110 2 Holes Ø9.0
(1.0) (0.39) (4.33) (0.35) Thro’

T P1

101.6
(4.0) 92
SYSTEM (3.62)
P2
65 K
(2.56)
169 MAX
21.0 26
(6.65)
(0.83) (1.02)

Check Valve

HighPressure
Relief Cartridge
1LR100-F-**-S

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-65
- Additional products, product lines, and services offered by Eaton -

K On-Line Tools
Ease of Doing Business
• Product Advisor • Expanded Eaton.com
(PVM, VMQ, DG-70,
Proportional and
Servo Valves)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-66 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Special housings - bolt on solutions
cartridge valves & manifolds for spool & disk valve motors

We manufacture solutions
Designing hydraulic systems
with Eaton-Vickers Cartridge
Valves & Manifolds is a cost
effective way of bringing your
design into production well
within the most demanding
of production schedules.
Minimizing the use of hoses,
tubing and fittings will reduce
production and assembly
time significantly.
Features
• Compatible with Eaton
H & T series spool valve
motors, and most 2000
series disk valve motors
• Aluminum Manifolds
Anodized Black
• Pre-set cartridges to your
specifications
• 100% production tested
assembly
• Wide range of settings
available
• Intelligent model code
• Manifolds are available with
out cartridge valves, or
pre-assembled and tested
to your specifications
• Manifolds and motors can
be supplied as a
pre-assembled package
• Dual counterbalance valve
(with integral shuttle valve),
dual pilot operated check
valve and dual cross port
relief valve packages are
available

Eaton H Series Hydraulic Motor

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-67
Dual cross-over relief package for
H&T series motors
Cartridge valves & manifolds for spool valve motors

Dual crossover relief valve How to order


assembly Complete pre-assembled selected for the cage seals, without the two RV3A
This valve assembly provides packages are specified using position 6 of the model code cartridges, order the part
motor over-pressure the RV3A-10 model code. is “H”. To order the manifold number 4997062-001.
protection in both directions Option “A” must be separately,
of rotation, while supplying
the return or lower pressure
side of the motor with Ratings and specifications
makeup oil. If closed center Rated flow 76 L/min(20USgpm)
valving is used, an additional Rated pressure 210 bar (3000psi)
function is controlled braking.
Internal leakage (maximum) less than 5 drops/min @ 85% of nominal setting
Typical applications are
Manifold sub-assembly only 4997060
vehicle propulsion and
motor work circuits in which Installation kit (includes cap screws, washers and o-rings) 02-372492
pressure limiting is required. For detailed specifications refer to the RV3A-10 data sheet on page E-210

Functional symbol Dimensions


mm (inch)

Port sizes
“A”, “B” – SAE10
“Brake” – SAE4

52,25
[2.057]

"B" 24,13
[0.950]
50,8 88,14
[2.000] [3.470]
65,02
4XØ 8,71 [2.560]
[0.343] EATON HYDRAULICS, INC.

Model Number
A B "B" "A" 4997062-001

"A"
69,85 24,13
[2.750] [0.950]
44,45
[1.750]
K
62,74
[2.470]

1,98 75,44 1,98


[0.078] [2.970] [0.078]

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-68 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Dual cross-over relief package
for 2000 series disc valve motors
Cartridge valves & manifolds for spool valve motors

Dual crossover relief valve How to order


assembly Complete pre-assembled To order the manifold
This valve assembly provides packages are specified using separately, without the
motor over-pressure the RV3A-10 model code. two RV3A cartridges, order
protection in both directions of Option “A” must be selected 4997060-001
rotation, while supplying the for the cage seals, position 6
return or lower pressure side of the model code is “2K”.
of the motor with makeup
oil. If closed center valving is
used, an additional function is
Ratings and specifications
controlled braking.
Rated flow 76 L/min(20USgpm)
Typical applications are vehicle
propulsion and motor work Rated pressure 210 bar (3000psi)
circuits in which pressure Internal leakage (maximum) less than 5 drops/min @ 85% of nominal setting
limiting is required. Manifold sub-assembly only 4997060-001
Installation kit (includes cap screws, washers and o-rings) 02-372492
For detailed specifications refer to the RV3A-10 data sheet on page E-14

Functional symbol Dimensions


mm (inch)

Port sizes
“A”, “B” – SAE10
“Brake” – SAE4

52,25
[2.057]

44,45 56,03
[1.750] [2.206]
"B" 82,55
[3.250]
3XØ10,31 100,84
[0.406] ® [3.970]
EATON HYDRAULICS, INC.

Model Number
4997060-001
A B "B" "A"

6,35 "A" 28,45


[0.250] [1.120]
53,85
[2.120]
K
62,74
[2.470]

1,98 88,14 1,98


Warning [0.078] [3.470] [0.078]
This manifold package may not
be suitable for application with
all 2000 series motors - please
check installation dimensions
carefully.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-69
1CESHHT35/1CEESHHT35 - Motor A
1CESHHT35/1CEESHHT35
mounted valves - Motor
Mounted Valves
H & T mounting pattern single and dual overcenter valve with brake release shuttle
H & T Mounting Pattern Single and Dual Overcenter Valve with Brake Release
Shuttle
A B A B A B

“A” Brake “B” “A” Brake “B” “A” Brake “B”


1CESHHT35*A 1CESHHT35*B 1CEESHHT35

Description 2.5:1Operation
& 5:1 Version 10:1 Version Pilot Ratios
Description
Overcenter Valves give Operation
0 10 The20 check
30 40section
50
The pressure pressure
allowsthe valveThe
required torequired
open
Flow - L/min Pilot
to ratios
2.5:1 Best suited for
and start actuator
open the valve
Overcenter
staticValves give
and dynamic 750 The check
control freesection
flow into allowsthe50actuator
movement 0can be 20 and30start
10calculated 2.5:1
40 Best suitedextremely
for extremely
unstable
static and dynamic control free flow into the actuator actuator
750 movement can be50 unstable applications
applications such as
of loads by regulating 600 the then holds and locks 40 theas follows:
of loads by regulating the then holds and locks the load such as long booms or or flexible

Pressure - bar
calculated as follows:
Pressure - psi

flow into long booms


flow into and outand out of
of hydraulic against load againstThe
movement. movement.
pilot The 600 40flexible frameworks.
30 valvePilot Pressure =

Pressure - bar
frameworks.

Pressure - psi
hydraulic 450
actuators. Whenactuators.
installed When assistedpilot reliefassisted relief
valve section Pilot Pressure = 5:1 B
 est suited for applications
close to or within
installed an actuator,
close to or 300
within will givesection controlled willmovement
give 20controlled 450
(Relief Setting) - (Load Pressure) 30 5:1 Best suited for
(Relief Setting) - (Load where load varies
Pressure)
the overcenter
an actuator, valvethewillovercenter when pilot pressure when
movement is applied.
pilot Pilot Ratio (Standard) applications
and machine where
stop runaway in the event 150 The relief section is normally 300 Pilot Ratio 20
valve will stop runaway in pressure is applied.
10 The structure canload varies (Standard)
induce
of hose burst and if open set to open at a pressure Pilot at instability and machine structure
150
centerthe event of
directional hose burst
control least 1.3relief
0 and timessection
the open is normally
maximum 0 Pilot
10
can induce instability
valvesifare open used, center directional0load2.5induced
will allow set
5 to7pressure
.5open 10 at a pressure
but
12.5 the at 0 open 10:10Best suited for
thermal expansion
control valves relief
areofused,
the will pressureFlow -required
leastUS1.3gpm to open
times thethe 0 2.5 5 7.5 10 applications where
10:1 Best the for
suited
hydraulic fluid. valve and allow movement load remains relatively
applications where
allow thermal expansion maximum load induced Flow - US gpm
depends on the pilot ratio of constant. the load remains
Theserelief
dual overcenter
of the hydraulic fluid. pressure but the pressure
valves also contain a brake the valve. For optimization relatively constant.
of load required
control and toenergy
open the valve
release shuttle valve which
These dual overcenter usage, aand
ensures that pressure is
allow
choice of movement
pilot ratios
valves also
applied to a brake release contain a brake is available.depends on the pilot ratio of
circuitrelease
regardless shuttle valve which
of whether the valve. For optimization
pressureensuresis applied thattopressure is of load control and energy
ports “A”
applied or “B”. These
Flow - L/min to a brake release Flow - L/min usage, a choice of pilot
4:1 Version 8:1 Version

multifunction valves are


0
normally
240 circuit
25 50
regardless
7
used for the
5 100
16 of whether
static 600
0 25 50
ratios
75 100
42 is available.
210 14
and pressure
180 dynamic control is applied
12 of to
500
ports 35
Pressure - bar
Pressure - psi

Pressure - bar
Pressure - psi

150
systems “A”using or “B” . These
10
motors
400
or multifunc- Performance
28
Data
120 8 300
Performance 21
data
semi-rotaryactuators.
90
tion valves are normally 6
200 14
60 4
Ratings and Specifications
30
0
used for
Piloted openthe
2 static and
0
100
0
Ratings and7 specifications
Piloted open 0
0
dynamic
6.5 13
control of systems
19.5 26 0 Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
6.5 13 19.5 26
Flow - US gpm Flow - US gpm
using motors or semi-rotary- Rated flow
Rated flow 30 L/min (8 USgpm)
30 L/min (8 USgpm)
actuators. Max setting Max setting Max load
Max load induced induced
Pressure:270 bar (4000
Pressure:    270psi)
bar (4000 psi)
Relief setting:   350 bar (5000
Relief setting: 350psi)
bar (5000 psi)
Cartridge material Working parts hardened & ground steel
Cartridge material Working parts
External hardened
surface & ground steel
zinc plated
Body material Standard aluminium External surface
(up to 210 bar*) zinc plated
K K Body material Standard Steel (up to 350(up
aluminium bar) to 210 bar*)
Mounting position Unrestricted
Steel (up to 350 bar)
Cavity Number
Mounting position A6610 (See section M)Unrestricted
Torque cartridge
Cavity into
Numbercavity 45 Nm (33 ibs
A6610 ft) section M)
(See
Weight Torque cartridge into cavity 1CESHHT35    2.29 kg   (5.0445lbs)
Nm (33 ibs ft)
(inc cartridges) 1CEESHHT35    2.34 kg   (5.15 lbs)
Weight
Seal kit number 1CESHHT35   9900828-000 (Buna-N)   9900829-000 (Viton) (5.04 lbs)
1CESHHT35 2.29 kg
(inc cartridges) 1CEESHHT35
1CEESHHT35   9900828-000 (Buna-N)   9900829-000 2.34 kg (5.15 lbs)
(Viton)
RecommendedSeal filtration
kit number level 1CESHHT35 9900828-000
BS5540/4 Class 18/13(Buna-N)
(25 micron 9900829-000
nominal) (Viton)
Operating Temp 1CEESHHT35 9900828-000 (Buna-N)
-30°C to +90°C (-22° to9900829-000
194°F) (Viton)
Leakage Recommended filtration level BS5540/4 Class 18/13
0.3 milliL/min nominal(25(5 micron
dpm) nominal)
Operating
Nominal viscosity rangeTemp -30°C to5 +90°C
to 500 cSt(-22° to 194°F)
Leakage 0.3 milliL/min
9900834-000 nominal (5 dpm)
(Buna-N)
Installation Kit (includes cap screws, washers, and o-rings)
Nominal viscosity range 9900835-000 (Viton) 5 to 500 cSt
Installation Kit (includes cap screws, washers, and o-rings) 9900834-000 (Buna-N)
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. 9900835-000 (Viton)
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
K-70 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
K-410.A.B EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015
1CESHHT35/1CEESHHT35 - Motor “A” “B” “A” “B” “A” “B”

mounted valves
1CEHT35*A 1CEHT35*B 1CEEHT35

1CEHT35/1CEEHT35 - Motor Mounted Valves H & T mounting pattern single and dual
H & T Mounting Pattern Single and Dual Overcenter Valves overcenter valve with brake release shuttle
2.5:1 & 5:1 Version 10:1 Version
Flow - L/min
0 10 20 30 40 50 0 10 20 30 40
750 50 750 50
600 40 600 40

Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
450 30 450 30
1CESHHT35/1CEESHHT35 - Motor 300 20 300 20
Mounted Valves 1502.5:1 & 5:1 Version 10 150 10:1 Version 10
H & T Mounting Pattern Single and Dual 0 10 20 30 40 50 APilot B Flow - AL/min B Pilot A B
750 0 open
50 0 010 open 0
0 20 30 40
Overcenter Valve with Brake Release Shuttle 600
0 2.5 5 7.5 10 12.5 750 0 2.5 5 7.550 10
Flow - US gpm 40 Flow - US gpm

Pressure - bar
Pressure - psi
600 40

Pressure - bar
Pressure - psi
450 30
1CE*SHHT35- F - A 10H - AG - 35 0 - 35 0 - S - 5
1CEEHT35 30010H -AG 20 - F 450- - 30 35 A 0
“A” “B” “A” “B” “A” “B”
300 20
1 2 3 4 5
150 6 7 8 Pilot
9 10 10
1CEHT35*A 11 1CEHT35*B 1CEEHT35
1 2 3 150 10
0 4 5 6open7 0 8 9 10 11 Pilot
0 2.5 5 7.5 10 12.5 0 open 0
1   Basic code 9   Pressure
Flow - US gpm setting (cart B) 0 2.5 5 7.5 10
1 Basic Code 0 – Std 9factory Pressure settingSetting (Cart B) Flow - US gpm
1CEESHHT35 – Double 1CEEHT35 Cartridge
- Double and Body and Body
Cartridge
1CESHHT35*A – Single overcenter in line A-”A” 1500 – 1500
0 – Std psi
factory setting
2.5:1 & 5:1 Version 10:1 Version
1CEHT35* - ASingle overcenter
1CE*SHHT35 -in line
F -A-”A” A 10H - AG - 35 15000– 1500 - 35psi0 Flow - S - 5
- L/min Flow - L/min
1CESHHT35*B – Single overcenter in
1CEHT35* - BSingle overcenter line B-”B” in line B-”B” 0 10 20 30 40 50 0 10 20 30 40
A B A 10B Seals 750 A B 50 750 50
1 2 3 4 5 10
6 Seals
7 8 9 10 11
2   Adjustment means 2 Adjustment Means S – Buna-N 600 40 600 40

Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
F – Screw Adjustment SV – S – Buna-N450
VitoN 30
F – Screw Adjustment SV – VitoN
450 30
1 Basic Code 9 Pressure Setting (Cart B)
300 20 300 20
1CEESHHT35 – Double
3 Housing Cartridge and Body
Material 011–  Std factory setting
3   Housing material
1CESHHT35*A – Single overcenter “A” in line“B” A-”A” “A” “B”
Pilot ratio
11 Pilot Ratio
150 “A” “B” 10 150 10
A – Aluminum 1500 – 1500 psi Pilot Pilot
1CESHHT35*B
A – Aluminum S – Steel– Single overcenter in line
1CEHT35*A B-”B” 2 –
1CEHT35*B 2.5:12 – 4:1 0 1CEEHT35 open 0 0 open 0
S – Steel 5 – 5:1
10 Seals 5 – 8:1
0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
2 Adjustment 4 Means 10 – 10:1 Flow - US gpm Flow - US gpm

Port Size Dual Housing Number S – Buna-N 10 – 8:1


F – Screw Adjustment
4 Code “A” & “B” Aluminum Steel SV – VitoN
Cavity plug part number
size 4WMaterial
3 Housing 1/2”housing BSP number 6024221-001 6024221-003Cavity plug part number
2.5:1 & 5:1 Version 10:1 Version
Port Dual
A – Aluminum 10H SAE 10 Flow - L/min
6024221-002| 11 PilotNitrile
Ratio
Flow - L/min
Code “A” & “B”10TBrake SAE 10 Aluminum 0 10 20 Steel 30 40 50 Nitrile0 AXP13032-01-N
S – Steel 750 6024221-04
50 – 2.5:110 20 30 40 50
2 750
AXP13032-01-N
4W 1/2”
4 BSP 1/4” BSP 6025216-001 6025216-003 5 – 5:1AXP13032-01-V 40
600 40 AXP13032-01-V
600
Pressure - bar

Pressure - bar
Pressure - psi

5 Port 10 – 10:1
Pressure - psi

Port Size Acted Upon Dual Housing Number


10H SAE 10 SAE 4 6025216-002
450 30 450 30
Code “A” A –& “B” A BrakePort Aluminum Steel
10T SAE
4W 10 1/2” SAE 4
B –BSP B1/4” Port BSP 6025216-001
300 6025216-004 20
6025216-003 300 20

10H SAEAB10 – A & BSAEPorts4(dual)6025216-002


150 10 150 10
Pilot Pilot
5   Port10TactedSAE upon 10 SAE 4 0 6025216-004
open 0 0 open 0
6 Pressure Range (Cart A) 0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
A – A Port5 Port Acted Upon
Note: Code Based on pressure in bar. Flow - US gpm Flow - US gpm
B – B PortA – A 20
Port
AB – A &BB– Ports – (2.5:1 and 5:1): 70-210 bar. Std setting 100 bar.
(dual)
B (10:1):
Port 100-210 bar. Std setting 100 bar.
AB –KA & B Ports (dual)
6   Pressure range 35 – (cart
(2.5:1 A)
and 5:1): 100-350 bar. Std setting 210 bar.
6 Pressure (10:1): 120-350
Range (Cartbar.A) Std setting 210 bar.
Note: Code Based on pressure in bar.
Note: Code Based on pressure in bar.
20 – (2.5:1 and 5:1):
20 100-210
(10:1):
7 70-210
– (2.5:1 and
Pressure
bar. 5:1):
Std
bar.
70-210
Std setting
Setting
setting bar.
(Cart A)100 bar.
100 Std bar.setting 100 bar.
K
(10:1):
0 – Std factory setting
35 – (2.5:1 and 100-210
5:1): bar. Std
100-350
1500 – 1500 psi bar.setting
Std 100 bar.
setting 210 bar. (10:1):
120-350 bar. Std
35 – (2.5:1 andsetting 210 bar.bar. Std setting 210 bar.
5:1): 100-350 Note: Note: For applica-
(10:1): 120-350 bar. Std setting 210B)bar. A B Note:
tions For applications
A over 210
B barover(3000
8 Pressure Range (Cart 210 bar
psi), (3000 psi),
please please con-
consult our
7   Pressure setting (cart
Note: Code Based A)
on pressure in bar. sult our technical
technical departmentor
department
7 Pressure Setting (Cart A) or use the steel body option.
0 – Std factory setting
20 – (2.5:1
0 – Std factory settingand 5:1): 70-210 bar. Std setting 100 bar. use the steel body option.
Tightening torque
Cartridges must of “F”
not be
1500 – 1500
1500psi (10:1):
– 1500 psi 100-210 bar. Std setting 100 bar. “A” Brake “B” adjuster locknut
“A” Brake “B” - 20 to 25 Nm
adjusted above the safe
35 – (2.5:1 and 5:1): 100-350 bar. Std setting 210 bar. 1CESHHT35*A Check motor
1CESHHT35*B
working mounting com-
pressure of the
8 Pressure
8   Pressure range Range
(cart (Cartbar.
B) B) Std setting 210 bar. patibility before specifying.
motor.
(10:1): 120-350 2.5:1 & 5:1 Version 10:1 Version
Note: Code Based on pressure in bar. 0 10 20 30 40 50 Flow - L/min
Note: Code Based on pressure in bar. 750 50 Tightening 0 torque
10 20 of
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
20 – (2.5:1 – (2.5:1
20and 5:1):and 5:1): bar.
70-210 70-210 Stdbar. Std setting
setting 100 bar. 100 bar. 600 40 “F” adjuster
750
locknut
Pressure - bar
Pressure - psi

(10:1): 100-210
(10:1): 100-210 A-28bar.bar.
K-472.A Std Std
setting setting
EATON
EATON Low100
100 bar.bar.
Speed
Screw-In High Torque
Cartridge Motors
Valves E-MOLO-MC001-E5
E-VLSC-MC001-E2 May 2015 June 2011 600
30 - 20 to 25 Nm Check
Pressure - psi

450

35 – (2.5:1
35and 5:1):and
– (2.5:1 100-350 bar. Stdbar.
5:1): 100-350 setting 210 bar.
Std setting 210 bar. 300
450
20 motor mounting

(10:1): 120-350
(10:1): 120-350 bar.bar.
Std Stdsettingsetting 210210 bar.bar. 150 10 compatibility
300
before
Pilot
0 specifying.
open 150
0
0 2.5 5 7.5 10 12.5 0
Where measurements
Where measurements areare
critical request
critical certifiedcertified
request drawings.drawings.
We reserveWe
the reserve
right to change specifications
the right to change without notice.
specifications without notice.
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 K-411.A
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-71
1CESH2K95/1CEESH2K95 - Motor
1CESH2K95/1CEESH2K95 - Motor A-3

Mounted Valves
mounted valves
2K Mounting2kPattern
mountingSingle andsingle
pattern Dualand
Overcenter Valvesvalves
dual overcenter
with Brake with
Release Shuttle
brake release shuttle
A B A B A B

“A” Brake “B” “A” Brake “B” “A” Brake “B”


1CESH2K95*A 1CESH2K95*A 1CEESH2K95

Description Operation Pilot Ratios


Description
Overcenter Valves give Operation
The check section allows
Therequired
The pressure pressuretorequired to open Pilotfor
4:1 Best suited Ratios
applications
Overcenter Valves give The check section open
allows the the valve
valve and and start actuator
start 4:1 
B est suited
static and dynamic control free flow into the actuator where load varies and for applications
movement can be calculated
static and dynamic
of loads by regulating the control free locks
then holds and flow into actuator movement can be
thethe actuator machine where load
structure can varies and
of loads by regulating then holds and locks the load as follows: machine structure can
flow into and out of load against movement. The calculated as follows: induce instability
the flow into and out of against movement. The pilot Pilot Pressure = induce instability
hydraulic actuators.
hydraulicWhen pilot assisted
actuators. When relief valve
assisted Pilot Pressure =
relief valve section 8:1 Best suited for
8:1 B
applications  where
est suited for applications
installed close to or close
installed section will will
withinto or within givegive
controlled
controlled movement (Relief Setting) - (Load Pressure)
(Relief Setting) - (Load Pressure) the load where the load remains
remains
an actuator,
an actuator, the overcenter the overcenter when
movement when pilot pilot pressure is applied. Pilot Ratio relatively constant.
valve will stop Pilot Ratio relatively constant.
valve will stop runaway inrunaway in
pressure is The reliefThe
applied. section is normally
the event ofthehoseevent
burstof hose
and burst andsection
relief setistonormally
open at a pressure at
Other ratios available upon
if open center directional least 1.3 times the maximum Other ratios available
if open center directional set to open at a pressure at request
control valves are used, will load induced pressure but the upon request
control valves arethermal
allow used, will least 1.3 times
expansion the required to open the
pressure
allow thermalrelief of the hydraulic maximum
expansion fluid. load
valveinduced
and allow movement
relief of the hydraulic fluid. pressure butdepends on the pilot ratio of
the pressure
These dual overcenter the valve. For optimization
valves also contain a brake required to open the valve
These dual overcenter of
and allow movement load control and energy
release shuttle valve which usage, a choice of pilot ratios
valves also contain a brake
ensures that pressure is depends on the pilot
is available. ratio of
applied
release shuttle valveto which
a brake release
the valve. For optimization
ensures thatcircuit regardless
pressure is of whether
of load control and energy
pressure
applied to a brake releaseis applied to usage, a choicePerformance
of pilot data
ports “A” or “B”. These
circuit regardless of whether
multifunction valves are ratios is available.
Ratings and specifications
pressure is applied
normallyto ports
used for the static
Performance FiguresData
based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
“A” or “B”. These multifunc-
and dynamic control of
Rated flow 90 L/min (23 USgpm)
systems
tion valves are normallyusing motors or
semi-rotary actuators. Max setting
Ratings and Specifications Max load induced
used for the static and Pressure:    270 bar (4000 psi)
dynamic control of systems Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS) Relief setting:   350 bar (5000 psi)
using motors or semi-rotary Rated flow Cartridge material 90 L/minparts
Working (23 hardened
USgpm) & ground steel
Max setting Max load induced External surface zinc plated
actuators.
Body material Pressure: Standard
270 bar aluminiumpsi)(up
(4000Steel to 210 bar*)
(up to 350 bar)
Relief setting: 350 bar (5000 psi)
Mounting position Unrestricted
Cartridge material Working parts hardened & ground steel
Cavity Number A12336 (See section M)
External surface zinc plated
Torque cartridge into cavity 60 Nm (44 ibs ft)
Body material Standard aluminium (up to 210 bar*)
kg   K
Weight 1CESH2K95   2.32 kg  (5.10 lbs)
(inc cartridges) Steel (up to   
1CEESH2K95  3502.42
bar) (5.32 lbs)
K Mounting position
Seal kit number Unrestricted
1CESH2K95   9900826-000 (Buna-N) 9900827-000 (Viton)
Cavity Number 1CEESHT35   9900826-000
A12336 (See(Buna-N) 9900827-000
section M) (Viton)
Recommended
Torque cartridge into cavity filtration level BS5540/4 Class 18/13 (25
60 Nm (44 ibs ft) micron nominal)
Weight Operating Temp 1CESH2K95 2.32 kg-30°C(5.10
to +90°C
lbs) (-22° to 194°F)
Leakage
(inc cartridges) 1CEESH2K95 2.42 kg0.3 milliL/min(5.32 lbs)nominal (5 dpm)
Seal kit numberNominal viscosity range 1CESH2K95 9900834-000 (Buna-N) 9900835-000 (Viton) 5 to 500 cSt
1CEESHT35
Installation Kit (includes cap screws, washers, and o-rings) 9900836-000 (Buna-N) 9900837-0009900830-000 (Buna-N)
(Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal) 9900831-000 (Viton)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Installation Kit (includes cap screws, washers, and o-rings) 9900828-000 (Buna-N)
9900829-000 (Viton)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 K-421.A
K-416.A
K-72 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CESH2K95/1CEESH2K95 - Motor
mounted valves
2K Mounting pattern single and dual overcenter valves
with brake release shuttle

A B A B A B

“A” Brake “B” “A” Brake “B” “A” Brake “B”


1CESH2K95*A 1CESH2K95*A 1CEESH2K95

Description Operation The pressure required to Pilot ratios


Overcenter Valves give The check section allows open the valve and start 4:1  Best suited for applications
static and dynamic control free flow into the actuator actuator movement can be where load varies and
of loads by regulating then holds and locks the calculated as follows: machine structure can
the flow into and out of load against movement. Pilot Pressure = induce instability
hydraulic actuators. When The pilot assisted relief 8:1  B
 est suited for applications
installed close to or within valve section will give (Relief Setting) - (Load Pressure) where the load remains
an actuator, the overcenter controlled movement Pilot Ratio relatively constant.
valve will stop runaway in when pilot pressure is
the event of hose burst and applied. The relief section
Other ratios available upon
if open center directional is normally set to open at a
request
control valves are used, will pressure at least 1.3 times
allow thermal expansion the maximum load induced
relief of the hydraulic fluid. pressure but the pressure
These dual overcenter required to open the valve
valves also contain a brake and allow movement
release shuttle valve which depends on the pilot ratio of
ensures that pressure the valve. For optimization
is applied to a brake of load control and energy
release circuit regardless usage, a choice of pilot
of whether pressure is ratios is available.
applied to ports “A” or “B”.
These multifunction valves Performance data
are normally used for the
static and dynamic control Ratings and specifications
of systems using motors or Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
semi-rotary actuators.
Rated flow 90 L/min (23 USgpm)
Max setting Max load induced
Pressure:    270 bar (4000 psi)
Relief setting:   350 bar (5000 psi)
Cartridge material Working parts hardened & ground steel
External surface zinc plated
Body material Standard aluminium (up to 210 bar*)
Steel (up to 350 bar)
Mounting position Unrestricted
Cavity Number A12336 (See section M)
Torque cartridge into cavity 60 Nm (44 ibs ft)
K
Weight 1CESH2K95   2.32 kg   (5.10 lbs)
(inc cartridges) 1CEESH2K95   2.42 kg   (5.32 lbs)
Seal kit number 1CESH2K95 9900834-000(Buna-N) 9900835-000 (Viton)
1CEESHT35  9900836-000 (Buna-N)  9900837-000 (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Installation Kit (includes cap screws, washers, and o-rings) 9900828-000 (Buna-N)
9900829-000 (Viton)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-73
1CLLROMP150 - Motor mounted relief
150 L/min (40 USgpm) 350 bar (5000 psi)

M1 A Operation Features
Pressure acts over one of two Single cartridge relieving in
differential areas forcing the both directions cutting down
poppet back allowing relief flow space requirements, giving full
to the other port. This being adjustment through its range
a single cartridge is ideal for on both pressures at the same
M2 B
mounting on to a motor in a spe- time.
cial housing.

Performance data
Ratings and specifications
Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Rated Flow 150 L/min (40 USgpm)
Max Setting 350 bar (5000 psi)
Cartridge Material Working parts hardened and ground steel.
External steel surfaces black oxide.
Body Material Standard aluminium (up to 210 bar*) Add Suffix ‘377’ for steel option
Mounting Position Unrestricted
Cavity Number A878 (See Section M)
Torque Cartridge into Cavity 60 Nm (44 lbs ft)
Weight 1.46 kg (3.21 lbs)
Seal Kit Number SK1280 (Nitrile) SK1280V (Viton)
Recommended Filtration Level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 5 milliL/min
Nominal Viscosity Range 5 to 500 cSt

Description Pressure drop


This is a direct acting bi-direc- Cartridge only
tional relief valve designed to
protect both lines in a circuit Flow - L/min
from over pressurization by 0 30 60 90 120 150
relieving oil to the other line. 5800 400
Ideal for use with motors or
5075 350
directional valves as a emer-
Pressure - bar
Pressure - psi

gency relief. Differential area, 4350 300


fast acting, poppet valve. 3625 250
2900 200
2175 150
1450 100
725 50
0 0
K 0 8 16 24 32 40
Flow - US gpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-74 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CLLROMP150 - Motor mounted relief
150 L/min (40 USgpm) 350 bar (5000 psi)

code
Model 1CLLROMP150 F
– 4W
– 35 S BK

1 2 3 4 5 6

1 Basic code 3 Port size 6 Mounting


1CLLROMP150 - Cartridge Code Port size Housing number BK - Bolt Kit
and Body
4W 1/2” BSP AXP24058-4W-S

2 Adjustment means
F - Screw Adjustment 4 
Adjustable pressure 5 Seals
range S - Nitrile
NNote: Code based on pressure (For use with most industrial
in bar. hydraulic oils)
35 - 114-350 bar. Std setting SV - Viton
280 bar* (For high temperature and
Std setting made at 14 L/min most special fluid applications)
* Cartridges must not be adjusted above
the safe working pressure of the motor

Dimensions Tightening torque of “F” NNotes: For applications over 210


adjuster locknut - 20 to 25 Nm bar (3000 psi), please consult our
mm (inch) technical department or use the
steel body option.

50.00 (1.97) 76.20 (3.00)

1CLLR100-F-35*

63.0
(2.5)
approx

30.00 B
28.00
M2 20.00 (1.18) (1.10)
(0.79)
20.00
(0.79) 20.00 66.00
(0.79) 36.00 95.00 (2.6)
(1.42) (3.74) K

M1 A

20.00
(0.79)
36.00
(1.42) 37.5 (1.48)

54.00 (2.13)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-75
1CLLROMS150 - Motor mounted relief
150 L/min (40 USgpm) 350 bar (5000 psi)

M1 A Operation Features
Pressure acts over one of two Single cartridge relieving in
differential areas forcing the both directions cutting down
poppet back allowing relief space requirements, giving full
flow to the other port. This adjustment through its range
being a single cartridge is ideal on both pressures at the same
M2 B for mounting on to a motor in time.
a special housing.

Performance data
Ratings and specifications
Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Rated Flow 150 L/min (40 USgpm)
Max Setting 350 bar (5000 psi)
Cartridge Material Working parts hardened and ground steel.
External steel surfaces black oxide.
Body Material Standard aluminium (up to 210 bar*) Add Suffix ‘377’ for steel option
Mounting Position Unrestricted
Cavity Number A878 (See Section M)
Torque Cartridge into Cavity 60 Nm (44 lbs ft)
Weight 1.46 kg (3.21 lbs)
Seal Kit Number SK1280 (Nitrile) SK1280V (Viton)
Recommended Filtration Level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 5 milliL/min
Nominal Viscosity Range 5 to 500 cSt

Description Pressure drop


This is a direct acting bi- Cartridge only
directional relief valve
designed to protect both Flow - L/min
lines in a circuit from over
pressurization by relieving oil 0 30 60 90 120 150
to the other line. Ideal for use 5800 400
with motors or directional 5075 350
Pressure - bar
Pressure - psi

valves as a emergency relief. 4350 300


Differential area, fast acting,
poppet valve. 3625 250
2900 200
2175 150
1450 100
725 50
0
K 0 8 16 24 32 40
0

Flow - US gpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-76 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CLLROMS150 - Motor mounted relief
150 L/min (40 USgpm) 350 bar (5000 psi)

code
Model 1CLLROMS150 F
– 4W
– 35 S BK

1 2 3 4 5 6

1 Basic code 3 Port size 6 Mounting


1CLLROMS150 - Cartridge and Code Port size Housing number BK - Bolt Kit
Body 4W 1/2” BSP AXP24059-4W-S

2 Adjustment means
F - Screw Adjustment 4 Adjustable pressure 5 Seals
range S - Nitrile
Note: Code based on pressure (For use with most industrial
in bar. hydraulic oils)
35 - 114-350 bar. Std setting SV - Viton
280 bar* (For high temperature and
Std setting made at 14 L/min most special fluid applications)
* Cartridges must not be adjusted above
the safe working pressure of the motor

Dimensions Tightening torque of “F” Note: For applications over 210 bar
adjuster locknut - 20 to 25 Nm (3000 psi), please consult our tech-
mm (inch) nical department or use the steel
body option.

1CLLR100-
F-35*

21.00 5.00 21.00


(0.82) (0.20) (0.82)
A

53.00
37.00 32.00 M1
(1.46) (1.26)
71.00
(2.80) B
(2.09) K
M2
22.00 18.00
5.00 (0.20) (0.87) 1.6 (0.71)
27.00 (0.06)
50.00 40.00
18.00 (0.71) (1.06) (1.97) (1.57)
63.50 (2.50)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-77
1CEOMP35/1CEEOMP35 - Motor
mounted valves
OMP mounting pattern single and dual overcenter valves

M1 M2 M1 M2 M1 M2

CT1 CT2 CT1 CT2

V1 V2 V1 V2 V1 V2
1CEOMP35-1 1CEOMP35-2 1CEEOMP35

Description Operation The pressure required to open Pilot Ratios


Overcenter valves give The check section allows the valve and start actuator 2.5:1 Best suited for
static and dynamic control free flow into the actuator movement can be calculated extremely unstable
of loads by regulating then holds and locks the load as follows: applications such as
the flow into and out of against movement. The pilot long booms or flexible
hydraulic actuators. When assisted relief valve section Pilot Pressure = frameworks.
installed close to or within will give controlled movement
(Relief Setting) - (Load Pressure) 5:1 Best suited for
an actuator, the overcenter when pilot pressure is applied.
Pilot Ratio applications where load
valve will stop runaway in The relief section is normally
varies (Standard)
the event of hose burst and set to open at a pressure at
and machine structure
if open center directional least 1.3 times the maximum
can induce instability
control valves are used, will load induced pressure but the
allow thermal expansion pressure required to open the 10:1 Best suited for
relief of the hydraulic fluid. valve and allow movement applications where the
depends on the pilot ratio of load remains relatively
The overcenter cartridge is
the valve. For optimization constant.
ideal for mounting directly
into a cavity machined in of load control and energy
the body of the cylinder, usage, a choice of pilot ratios
motor or rotary actuator. is available.
The cartridge can also be
mounted directly to the
ports via a specifically Performance data
machined body as part of a
Hydraulic Integrated Circuit
or single unit, or contained Ratings and specifications
within one of our standard Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
line bodies. Rated flow 30 L/min (8 USgpm)
Single overcenter valves are Max setting Max load induced
normally used when the load Pressure:    270 bar (4000 psi)
is unidirectional, for example Relief setting:   350 bar (5000 psi)
an aerial platform or crane Cartridge material Working parts hardened & ground steel
and dual overcenter valves External surface zinc plated
are used for controlling loads Body material Standard aluminium (up to 210 bar*)
Add suffix '377' for steel option
in both directional for motor
applications or for cylinders Mounting position Unrestricted
K going over center. Cavity Number A6610 (See section M)
Torque cartridge into cavity 45 Nm (33 ibs ft)
Weight 1CEOMP35  1.6 kg  (3.52 lbs)
(inc cartridges) 1CEEOMP35  1.66 kg  (3.65 lbs)
Seal kit number 1CEOMP35  SK1285 (Nitrile)  SK1285V (Viton)
1CEEOMP35  SK1284 (Nitrile)  SK1284V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-78 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CEHT35/1CEEHT35 - Motor
1CEHT35/1CEEHT35 - Motor A-3
Mounted Valves mounted valves
H & T Mounting Pattern Single and Dual Overcenter Valves H & T Mounting pattern single and dual overcenter valves

A B A B A B

“A” “B” “A” “B” “A” “B”

1CEHT35*A 1CEHT35*B 1CEEHT35

Description Operation Pilot Ratios


Description Operation The pressure required to Pilot Ratios
Overcenter valves give The check section allows The pressure required to
2.5:1 Best suited for
Overcenter valves give
static and dynamic control The
freecheck
flow intosection
theallows
actuator open the valve and start 2.5:1 B extremely
est suited unstable
for
static and dynamic control free flow into the actuator open the valve and start extremely unstable
of loads by regulating then holds actuator movement can be applications such as
of loads by regulating the then
2.5:1 holds
& 5:1 and locks thethe
Version and locks load actuator movement can be
10:1 Version
calculatedasasfollows:
follows: applications
long boomssuch as
or flexible
the flow into and out
flow into and out of hydraulicof load
against
Flow against
movement.
- L/min movement.
The pilotThe calculated
Flow - L/min long booms or flexible
frameworks.
hydraulic actuators. When
actuators. When installed 0 10assistedpilot assisted
relief reliefsection
valve valve Pilot Pressure frameworks.
20 30 40 50 0 10 = 20 30 40
close to orclose
installed withintoanoractuator,
within
750 will give controlled
section movement
will give controlled
50 Pilot Pressure =
750 Setting) - (Load Pressure) 505:1 Best suited for
(Relief 5:1 Best suited for
the overcenter
an actuator, valve
the will
overcenter when
movement pilot pressure
when pilot is applied. (Relief Setting) - (Load Pressure) applications where load
600 40 Pilot Ratio applications where load
stop
valverunaway
will stopin runaway
the event in The relief section
pressure is normally
is applied. The 600 Pilot Ratio 40 varies (Standard)
varies (Standard) and
Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
of hose burst and if open set to open at a pressure at and machine structure
the event of hose burst
450 and relief section is normally
30 450
machine structure can
center directional control least 1.3 times the maximum 30 can instability
induce instability
if openare center induce
valves used,directional
will allow set to
load open pressure
induced at a pressurebut theat
control valves
thermal expansionare relief
used,
300will least 1.3required
pressure times the to 20
open the 300 10:1Best
10:1
20 Best suited
suited forfor
of the thermal
allow hydraulicexpansion
fluid. The valve
maximum and allowloadmovement
induced applicationswhere
applications wherethethe
overcenter cartridge 150
is ideal depends 10 150 10 load
load remainsrelatively
remains relatively
relief of the hydraulic fluid. pressureon butthe pilot
the
Pilot ratio of
pressure Pilot
for mounting directly into a the valve. For optimization
open open constant.
constant.
The overcenter cartridge0 is required to open the 0 valve 0 0
cavity machined in the body 0 2.5of load control 10and
12.5energy
ideal
of thefor mounting
cylinder, motordirectly
or and5 allow
usage, a
7.5 movement
choice of pilot ratios
0 2.5 5 7.5 10
into a actuator.
cavity machined in Flow - US gpm
depends Flow - US gpm
rotary is available.on the pilot ratio of
the body of the cylinder,
The cartridge can also be
the valve. For optimization
motor or directly
mounted rotary actuator.
to the ports of load control and energy
via a specifically machined usage, a choice
Performance of pilot
data
The cartridge
body as part ofcan also be
a Hydraulic ratios is available.
Integrated Circuit ortosingle
mounted directly the Ratings and specifications
unit,
portsorvia
contained within one
a specifically Performance Data
of our standard line bodies. Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
machined body as part of a Rated flowand Specifications 30 L/min (8 USgpm)
Single overcenter valves are ratings
Hydraulic Integrated Circuit Max load induced
normally used when the load Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
or single unit, or contained Max setting Pressure:     270 bar (4000 psi)
is unidirectional, for example Rated flow Relief setting:   30 350
L/min bar(8(5000
USgpm)
psi)
within
an aerialone of ourorstandard
platform crane
line dual
bodies. Max setting Working
Max loadparts hardened & ground steel
induced
and overcenter valves Cartridge material
are used for controlling loads Pressure: External surface
270 barzinc plated
(4000 psi)
Standard aluminium (up to 210 bar*)
in both overcenter
Single directional for motorare
valves Body material Relief setting: 350 (up
Steel barto(5000 psi)
350 bar)
applications
normally used or for cylinders
when the load Cartridgeposition
Mounting material Working parts hardened & ground steel
Unrestricted
going over center. ExternalA6610surface
is unidirectional, for example Cavity Number (Seezinc
section plated
M)
Body material Standard aluminium (up to 210 bar*)
an aerial platform or crane Torque cartridge into cavity 45 Nm (33 ibs ft)
Steel (up to 350 bar)
K
and dual overcenter valves
are used for controlling loads
Weight
Mounting(inc cartridges)
position
1CEOMP35  1.6 kg (3.52 lbs)
1CEEOMP35   1.66 kg  Unrestricted
(3.65 lbs) K
in both directional for motor Cavity
Seal Number
kit number A6610 (See section
1CEHT35   9900834-000 (Buna-N) 9900835-000  M)
(Viton)
1CEEHT35  9900836-000 (Buna-N 9900837-000 (Viton)
applications or for cylinders Torque cartridge into cavity 45 Nm (33 ibs ft)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
going over center. Weight 1CEOMP35 1.6 kg (3.52 lbs)
Operating Temp
(inc cartridges) 1CEEOMP35-30°C to +90°C
1.66 kg(-22° to 194°F)
(3.65 lbs)
Leakage
Seal kit number 1CEHT35 0.3 milliL/min nominal
9900834-000 (Buna-N) 9900835-000 (Viton) (5 dpm)
Nominal viscosity range 1CEEHT35 9900836-000 (Buna-N) 9900837-000 5 to 500 cSt
(Viton)
Recommended filtration level BS5540/4 Class 9900828-000 (Buna-N)
18/13 (25 micron nominal)
Installation Kit (includes cap screws, washers, and o-rings) 9900829-000 (Viton)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Installation Kit (includes cap screws, washers, and o-rings) 9900828-000 (Buna-N)
9900829-000 (Viton)
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
EATON Low
Where measurements areSpeed High Torque
critical request certified Motors
drawings. E-MOLO-MC001-E5 June specifications
We reserve the right to change 2011 A-27
without notice.
EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 K-471.A .B
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-79
1CEHT35*A 1CEHT35*B 1CEEHT35

1CEHT35/1CEEHT35
1CEHT35/1CEEHT35 - -Motor
Motor Mounted Valves
Hmounted
& T Mountingvalves
Pattern Single and Dual Overcenter Valves
H & T Mounting pattern single and dual overcenter valves 2.5:1 & 5:1 Version 10:1 Version
Flow - L/min Flow - L/min
0 10 20 30 40 50 0 10 20 30 40
750 50 750 50
600 40 600 40

Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
450 30 450 30

300 20 300 20

150 10 150 10
APilot B A B Pilot A
0 open 0 0 open 0
0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
Flow - US gpm Flow - US gpm

1CEEHT35 - F - A 10H - AG - 35 0 - 35 0 - S - 5
1CEEHT35 - F A 10H AG
- - - 35 0 - 35 0 -
“A” S -“B”5 “A” “B” “A”

1CEHT35*A 1CEHT35*B 1CEEHT


1 2 3 4 5 6 7 8 9 10 11
1 2 3 4 5 6 7 8 9 10 11

1 1Basic Code
Basic code 99 Pressure
Pressure Setting
setting(Cart(CartB)B)
1CEEHT35 - Double Cartridge and Body 0 – Std
Std factory
factorysetting
setting
1CEEHT35 - Double Cartridge and Body 2.5:1 & 5:1 Version 10:1 Version
1CEHT35*
1CEHT35* -- ASingle overcenterininline
ASingle overcenter lineA-”A”
A-”A” 1500 –– 1500
1500 1500psipsi Flow - L/min Flow - L/min
1CEHT35* - BSingle overcenter
1CEHT35* - BSingle overcenter
A
in line B-”B”
inB line B-”B” A B
0
A
10 20
B
30 40 50 0 10 20 30 40
750 50 750 50
10 Seals
10 Seals 600 40
2 2Adjustment Means
Adjustment means
600 40

Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
S–
S Buna-N
– Buna-N
F – Screw Adjustment SV – VitoN450 30 450 30
F – Screw Adjustment SV – VitoN
300 20 300 20
3 Housing Material 11 Pilot ratio
3 Housing material“A” “B” “A” “B” 11 Pilot Ratio
150 “A” “B”
10 150 10
A – Aluminum Pilot Pilot
Aluminum 4 – 4:1
SA––Steel 1CEHT35*A 1CEHT35*B
28 –– 8:1
4:1 0 1CEEHT35 open 0 0 open 0
S – Steel 0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
4 510––8:1
8:1 Flow - US gpm Flow - US gpm

Port Size Dual Housing Number 10 – 8:1


4
Code “A” & “B” Aluminum Steel
4W Port size
1/2” BSP 6024221-001 Dual housing number
2.5:1 & 5:1 Version 6024221-003
Cavity
Cavity plugpart
plug
10:1 Version
partnumber
number
10H
Code SAE 10“A” & “B” Flow
6024221-002| - L/min
Aluminum Steel Nitrile
Flow - L/min
Nitrile
10T
4W SAE 101/2” BSP750 0 10 6024221-001
20 30 40 50
6024221-04
6024221-003
50 750
0 10 20
AXP13032-01-N
AXP13032-01-N 30 40
50
AXP13032-01-V
AXP13032-01-V
10H SAE 10 600 6024221-002 40 600 40
Pressure - bar

Pressure - bar
Pressure - psi

5 Port Acted Upon


Pressure - psi

A 10T A Port SAE 10 450 6024221-04


30 450 30

B– B Port 300 20 300 20
5 Port acted upon
AB – A & B Ports (dual) 150 10 150 10
Pilot Pilot
A – A Port 0 open 0 0 open 0
6B –Pressure
B Port Range (Cart A) 0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
Note: – A Based
AB Code & B Ports (dual)
on pressure in bar. Flow - US gpm Flow - US gpm

20 – (2.5:1 and 5:1): 70-210 bar. Std setting 100 bar.


6 Pressure range (Cart A)
(10:1): 100-210 bar. Std setting 100 bar.
K Note: Code Based on pressure in bar.
K 20––(2.5:1
35 (2.5:1 and
and 5:1): 100-350
5:1): 70-210 bar.bar.
Std Std setting
setting 210 bar.
100 bar.
(10:1):(10:1):
120-350 bar. bar.
100-210 StdStd
setting
setting210
100bar.
bar.
35 – (2.5:1 and 5:1): 100-350 bar. Std setting 210 bar.
(10:1): 120-350
7 Pressure Settingbar. Std A)
(Cart setting 210 bar.
0 – Std factory setting
7 –Pressure
1500 1500 psi setting (Cart A)
Note: For applications
0 – Std factory setting over 210 bar (3000 psi),
81500 – 1500 Range
Pressure psi (Cart B) please consult our tech-
Note: Code Based on pressure in bar. nical department or use
the steel body option.
208– (2.5:1
Pressure range
and 5:1): (Cart bar.
70-210 B) Std setting 100 bar. Tightening torque of “F”
Note: Code Based on pressure
(10:1): 100-210 bar. Std setting in 100
bar. bar. adjuster locknut -
20 – (2.5:1 and 5:1): 70-210 bar. Std setting 100 bar. 20 to 25 Nm Check
35 – (2.5:1
(10:1):and 5:1):bar.
100-210 100-350 bar. Std
Std setting 100 setting
bar. 210 bar. motor mounting compat-
(10:1): 120-350
35 – (2.5:1 bar. 100-350
and 5:1): Std setting 210setting
bar. Std bar. 210 bar. ibility before specifying.
(10:1): 120-350 bar. Std setting 210 bar.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
A-28
K-472.A Low Speed
EATON Screw-In
EATON High Torque
Cartridge Motors
Valves E-MOLO-MC001-E5
E-VLSC-MC001-E2 May 2015 June 2011
K-80 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CE2K95/1CEE2K95 - Motor 1CE2K95/1CEE2K95 - Motor
mounted valves A-3
Mounted Valves 2K Mounting pattern single and dual overcenter valves
2K Mounting Pattern Single and Dual Overcenter Valves

A B A B A B

“A” “B” “A” “B” “A” “B”

1CE2K95*A 1CE2K95*B 1CEE2K95

Description Operation The pressure required to Pilot Ratios


Description
Overcenter valves give Operation
The check section allows Theopen the valve
pressure requiredandtostart Pilot
4:1Ratios
Best suited for
open the valve
actuator and start can be
movement applications
static andvalves
Overcenter dynamic give control The free flow into the
check section allows actuator 4:1 Best suited for where load
static and dynamic controlthe actuator movement
calculated can be
as follows: varies andwhere
machine
of loads by regulating free flowholds
then into theandactuator
locks the applications load
of flow
loadsinto
by regulating the calculated as follows: structure can induce
and out of then
load holds and locks
against the loadThe
movement. varies and machine
Pilot Pressure =
flow into and out of hydraulic against instability
hydraulic actuators. When pilot movement.
assisted relief Thevalve
pilot structure can induce
actuators. When installed assisted relief valve section Pilot(Relief Setting)
Pressure = - (Load Pressure) instability
installed close to or
close to or within an actuator, within section will give
will give controlled movementcontrolled 8:1 Best suited for
theanovercenter
actuator, valve
the overcenter
will movement whenispilot (Relief Setting) Pilot Ratio
- (Load Pressure) 8:1 B est suited for where
applications applications
the
when pilot pressure applied.
Pilot Ratio where
load remains remains
the load relatively
valve
stop will stop
runaway in therunaway
event in Thepressure is applied.
relief section The
is normally
relatively constant.
constant.
of the
hoseevent
burstof and if open
hose burst and setrelief
to open at a pressure
section is normallyat
center directional
if open center control
directional least
set1.3to times
open the at amaximum
pressure at Other ratios available upon
valves are used, will allow Other ratios available upon
request
control valves are used, will load induced
least pressure
1.3 times the but the request
thermal expansion relief of pressure required to open the
theallow thermal
hydraulic fluid.expansion maximum
valve and allow load induced
movement
relief of the hydraulic fluid. depends pressure but pilot
on the the pressure
ratio of
The overcenter cartridge is
ideal therequired
valve. to
For open the
optimization valve
Theforovercenter
mounting directly
cartridge is
into a cavity machined in the of and
load allow
controlmovement
and energy
ideal for mounting directly usage, a choice of pilot ratios
body depends on the pilot ratio of
intoofathe cylinder,
cavity motorin
machined orthe
is available.
rotary actuator. The cartridge the valve. For optimization
canbody
also of
bethe cylinder,
mounted directly of load control and energy
to motor
the portsor via
rotary actuator.
a specifically usage, a choice of pilot
The cartridge
machined body ascan partalso
of abe
ratios is available.
Performance data
mounted
Hydraulic directly Circuit
Integrated to the
or ports
singleviaunit,
a or contained
specifically
within one of body
our standard Performance
Ratings and specificationsData
machined as part of a
line bodies. Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Hydraulic Integrated Circuit Ratings and Specifications
Single overcenter
or single valves
unit, or are
contained Rated flow 4:1 Version 90 L/min (23 USgpm)
8:1 Version
normally used when the load Figures based on: Oil Temp = 40°C Viscosity
Flow - L/min = 32 cSt (150 SUS)
within one of our standard MaxRated setting MaxFlow
load -induced
L/min
is unidirectional, for example flow 0 2 5 5 0 75 100 50 90
0 Pressure:    
25 L/min
270
75 bar (23
100 (4000USgpm)
psi)
anline bodies.
aerial platform or crane Max setting
240
210
16
14
600Relief setting:    350 bar (5000
Max load induced 42 psi)
and dual overcenter valves Cartridge material Working
500
Pressure:parts hardened270 & ground
bar35 steel
(4000 psi)
Single overcenter valves are
Pressure - bar

180
Pressure - psi

12
Pressure - bar
Pressure - psi

are used for controlling loads External surface zinc plated


400Relief setting:
normally used when the load Body material 150 10 350 bar 28(5000 psi)
in both directional for motor Standard aluminium (up to 210 bar*)
is unidirectional,
applications for example Cartridge material
or for cylinders
120 8 Working
300 parts hardened & ground
Steel (up steel
to21350 bar)
an aerial platform
going over center. or crane Mounting position 90 6
200 External surface zinc plated
Unrestricted
14
60 4
and dual overcenter valves Cavity Body material
Number Standard aluminium (up section
A12336 (See to 210 M)bar*)
30 2 100
Steel
7
(up0(44
to 350 K
K
are used for controlling loads Torque cartridge into cavity 0 Piloted open 0 0 Piloted open
60 Nm ibs ft)bar)
Mounting
in both directional for motor Weight position
(inc cartridges) 0 6.5 13 19.5 26 0 1CE2K95   2.16
6.5 26Unrestricted
13 19.5 kg (4.75 lbs)
Cavity Number Flow - US gpm Flow - US gpm (See
A12336
1CEE2K95  2.26 section
kg (4.97 lbs) M)
applications or for cylinders
going over center. SealTorque
kit number
cartridge into cavity 1CE2K95   9900826-000 (Buna-N) 9900827-000 (Viton)
60 Nm (44 ibs ft)
1CEE2K95   9900826-000 (Buna-N) 9900827-000 (Viton)
Weight 1CE2K95 2.16 kg (4.75 lbs)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
(inc cartridges) 1CEE2K95 2.26 kg (4.97 lbs)
Operating Temp -30°C to +90°C (-22° to 194°F)
Seal kit number 1CE2K95 9900826-000 (Buna-N) 9900827-000 (Viton)
Leakage 1CEE2K95 0.3 milliL/min
9900826-000 (Buna-N) nominal (5 dpm)
9900827-000 (Viton)
Nominal viscosity range
Recommended filtration level BS5540/4 Class 18/13 (25 micron 5 to 500 cSt
nominal)
Installation Kit
Operating Temp (includes cap screws, washers, and o-rings) 9900830-000 (Buna-N)
-30°C to9900831-000 (Viton)
+90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt
Installation Kit (includes cap screws, washers, and o-rings) 9900830-000 (Buna-N)
9900831-000 (Viton)

WhereWhere measurements
measurements are critical
are critical request
request certified
certified drawings.
drawings. We reserve
We reserve the right
the right to change
to change specifications
specifications without
without notice.
notice.

EATON
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) Screw-In Cartridge Valves
E-VLSC-MC001-E6—January E-VLSC-MC001-E2
2018 May 2015
www.eaton.com K-473.A
K-81
1CE2K95/1CEE2K95 Motor Mounted Valves
1CE2K95/1CEE2K95 - Motor
mounted
2K valves
Mounting Pattern Single and Dual Overcenter Valves
1CE2K95/1CEE2K95
2K Mounting pattern single and dual overcenter valvesMotor Mounted
4:1 Version
Valves 8:1 Version
2K Mounting Pattern Single and Dual Overcenter Valves
Flow - L/min Flow - L/min
0 25 50 75 100 0 25 8:150 75 100
4:1 Version Version
240 16
Flow - L/min
600 Flow - L/min
42
210 0 25 50 1475 100 500 0 25 50 75 100 35

Pressure - bar
180

Pressure - psi
240 12 16 600 42

Pressure - bar
Pressure - psi
210 14
150 10 400 500 35 28

Pressure - bar
180

Pressure - psi
12

Pressure - bar
Pressure - psi
120 150 8 400 28
10 300 21
90 120 8 300 21
6
90 6 200 14
60 60 4 4
200 14

30 30 2 2
100 100 7 7
0 Piloted
0 openPiloted0 open 0 0 0 Piloted open0 0
Piloted open
0 6.5 13 19.5 26 0 6.5 13 19.5 26
0 6.5 13 19.5 26
Flow - US gpm 0 6.5Flow -13 19.5 26
US gpm
Flow - US gpm Flow - US gpm
1CEE2K95 - F -1CEE2K95 - F - A 10H - AG - 35 0 - 35 0 - S - 5
A 10H - AG - 35 0 - 35 0 - S - 5
1CEE2K95 - F - A 10H - AG - 35 0 - 35 0 - S - 5
1 2 3 1 4 52 6
3 74 8 5 9 6 7 11
10 8 9 10 11

1 Basic
1 Code 2 3 4 5 6 710 Seals
8 9 10 11
1 Basic code 1CEE2K95 Double Cartridge and Body 10 SealsS – Buna-N
1CE2K95*A Single overcenter in line A-”A”
11CEE2K95 Double
Basic Code Cartridge and Body Buna-NSV – VitoN
S – Seals
10
1CE2K95*B Single overcenter in line B-”B”
Single Cartridge
1CE2K95*ADouble
1CEE2K95 overcenterand
in line A-”A”
Body SV – VitoN
1CE2K95*B Single overcenter in line B-”B” S – Buna-N11 Pilot Ratio A B A B A
2 Adjustment
1CE2K95*A Single overcenter in line A-”A” Means
11 – VitoN
SV – 4:1
F – Screw Adjustment
1CE2K95*B Single overcenter in line B-”B” Pilot 4ratio
8 – 8:1
2 Adjustment means 4 – 4:1
3 Housing Material 11 Pilot Ratio A B A B
Screw Adjustment
2F –Adjustment Means A – Aluminum 8 – 8:1 Cavity plug part number

F – Screw Adjustment S – Steel 4 – 4:1 Nitrile “A” “B” “A” “B” “A”

8 – 8:1 AXP14434-02-N 1CE2K95*A


3 Housing material 4 1CE2K95*B 1CEE2K

Port Size Dual Housing Number Viton


3A –Housing Material
Aluminum Steel Cavity plug AXP14434-02-V
part
partnumber
Code “A” & “B” Aluminum
Steel
AS––Aluminum 4W 1/2” BSP
Cavity
6025185-001 6025185-003
plug number
10H SAE 10 6025185-002 Nitrile
S – Steel Nitrile “A” “B” “A” “B”
4 10T SAE 10 6025185-004
AXP14434-02-N
4 AXP14434-02-N 1CE2K95*A 1CE2K95*B
5 Port Acted Upon Viton
Viton
Port Size
Port size Dual Housing Dual Number
housing number
A– A Port
Code “A” & “B” Aluminum Steel AXP14434-02-V
AXP14434-02-V
Code “A” & “B”B – BAluminum
Port Steel
4W 1/2” BSP 6025185-001
AB – A & B Ports (dual) 6025185-003
4W
10H SAE 101/2” BSP 6025185-002 6025185-001 6025185-003
6 Pressure Range (Cart A)
10T
10H SAE 10 SAE 10 6025185-002 6025185-004
Note: Code Based on pressure in bar.
10T SAE 10 6025185-004
20 – 70-225 bar. Std setting 100 bar.
5 Port Acted Upon K 35 – 200-350 bar. Std setting 210 bar.
A 5– PortAacted
Port upon
BA–– A PortB Port 7 Pressure Setting (Cart A)
0 – Std factory setting
B ––BAPort
AB & B Ports (dual)
1500 – 1500 psi
AB – A & B Ports (dual)
6 Pressure Range (Cart 8A)Pressure Range (Cart B)
Note:
6 Code Based on range
Pressure pressure in bar. Note:
(cart A)Code Based on pressure in bar. Note: For applications over
4:1 Version

20 – 70-225 bar. Std setting 100 bar. 210 bar (3000 psi),Flow
please con-
- L/min

20 – 70-225
Note: Code bar.
BasedStd on setting 35 – 100
pressure bar.bar. Std setting 210 bar.
in bar.
200-350 sult our 240 0
technical 25 50
department 75 100
16 600
0

K 20––200-350
35 bar.StdStd
70-225 bar. setting
setting 100210bar. bar. or use the
210steel body option. 14 500

K Tightening
180torque of “F” Pressure - bar
Pressure - psi

12

Pressure - psi
35 – 200-350 bar. Std setting 210 bar.Setting (Cart B)
9 Pressure adjuster150
locknut - 20 to 25 Nm 10 400
120 8 300
0 – Std factory setting Check motor mounting com-
90 6
7 Pressure Setting (Cart A)– 1500 psi
1500
patibility 60
before specifying. 200
7 Pressure setting (cart A) 4
100
0 – Std factory setting Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
30
0 Piloted open
2
0 0
0 – Std
1500 factory
– 1500 psisetting A-24 EATON Low Speed High Torque Motors E-MOLO-MC001-E5 June 2011 0 6.5 13 19.5 26 0
1500 – 1500 psi K-474.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 Flow - US gpm

8 Pressure Range (Cart B)


8 Pressure range (cart B) NNotes: For applications
Note: Code Based on pressure in bar.
Note: Code Based on pressure in bar. over 210 bar (3000 psi),
20––70-225
20 70-225 bar. Stdsetting
bar. Std setting 100
100 bar.
bar. please consult our
100
35––200-350
35 200-350 bar. Stdsetting
bar. Std setting 210
210 bar.bar. technical department or 16
use the steel body option. 14
Tightening torque of “F”
Pressure - bar

12
99Pressure Setting
Pressure (Cart
setting B)B)
(cart adjuster locknut - 10
20 to 25 Nm Check motor 8
Std factory
00––Std factory setting
setting
mounting compatibility 6
1500 1500 psi
1500 –– 1500 psi before specifying. 4
2
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. 0 Piloted open 0
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
A-24 EATON Low Speed High Torque Motors E-MOLO-MC001-E5 June 2011 0 6.5 13 19.5 26
K-474.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E2 May 2015 Flow - US gpm
K-82 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CEOMS95/1CEEOMS95 - Motor
mounted valves
OMS Mounting pattern single and dual overcenter valves

M1 M2 M1 M2 M1 M2

CT1 CT2 CT1 CT2

V1 V2 V1 V2 V1 V2

1CEOMS95-1 1CEOMS95-2 1CEEOMS95

Description Operation Pilot Ratios


Overcenter valves give The check section allows The pressure required to open 4:1 Best suited for
static and dynamic control free flow into the actuator the valve and start actuator applications where load
of loads by regulating the movement can be calculated varies and machine
then holds and locks the load
flow into and out of hydraulic as follows: structure can induce
against movement. The pilot instability
actuators. When installed
assisted relief valve section
close to or within an actuator, Pilot Pressure = 8:1 Best suited for
the overcenter valve will will give controlled movement
(Relief Setting) - (Load Pressure) applications where the
stop runaway in the event when pilot pressure is applied.
Pilot Ratio load remains relatively
of hose burst and if open The relief section is normally constant.
center directional control set to open at a pressure at
valves are used, will allow least 1.3 times the maximum Other ratios available
thermal expansion relief of the load induced pressure but the upon request
hydraulic fluid. pressure required to open the
The overcenter cartridge is valve and allow movement
ideal for mounting directly depends on the pilot ratio of
into a cavity machined in the the valve. For optimization
body of the cylinder, motor or of load control and energy
rotary actuator. The cartridge usage, a choice of pilot ratios
can also be mounted directly
is available.
to the ports via a specifically
machined body as part of a
Hydraulic Integrated Circuit
or single unit, or contained
Performance data
within one of our standard line
bodies. Ratings and specifications

Single overcenter valves are Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
normally used when the load Rated flow 90 L/min (23 USgpm)
is unidirectional, for example Max setting Max load induced
an aerial platform or crane Pressure:       270 bar (4000 psi)
and dual overcenter valves Relief setting:   350 bar (5000 psi)
are used for controlling loads Cartridge material Working parts hardened & ground steel
in both directional for motor External surface zinc plated
applications or for cylinders Body material Standard aluminium (up to 210 bar*)
Add suffix '377' for steel option
going over center.
Mounting position Unrestricted
Cavity Number A12336 (See section M)
Torque cartridge into cavity 60 Nm (44 ibs ft) K
Weight 1CEOMS95  2.16 kg  (4.75 lbs)
(inc cartridges) 1CEEOMS95  2.26 kg  (4.97 lbs)
Seal kit number 1CEOMS95  SK1282 (Nitrile)  SK1282V (Viton)
1CEEOMS95  SK795 (Nitrile)  SK795V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-83
1CEOMP35/1CEEOMP35 - Motor
mounted valves
OMP Mounting pattern single and dual overcenter valves

Pressure drop 2.5:1 & 5:1 Version 10:1 Version


Flow - L/min Flow - L/min
0 10 20 30 40 50 0 10 20 30 40
750 50 750 50
600 40 600 40

Pressure - bar

Pressure - bar
Pressure - psi

Pressure - psi
450 30 450 30
Free flow Free flow
300 20 300 20

150 10 150 10
Pilot Pilot
0 open 0 0 open 0
0 2.5 5 7.5 10 12.5 0 2.5 5 7.5 10
Flow - US gpm Flow - US gpm

code
Model 1CE*OMP35-* F
– 4W
– 35 S 5 BK
1 2 3 4 5 6 7

1 Basic code 3 Port size 6 Pilot ratio


Code Port size Housing number
1CEEOMP35 - Double 2 - 2.5:1
Cartridge and Body 4W 1/2" BSPP BXP24052-4W-S 5 - 5:1
1CEOMP35-1 - Single 10 - 10:1
overcenter in line V1-M1 4 Pressure range 5 Seals
1CEOMP35-2 - Single 7 Mounting
Note: Code based on pressure S - Nitrile
overcenter in line V2-M2
in bar. (For use with most industrial BK - Bolt Kit
20 - (2.5:1 and 5:1): 70-210 bar. hydraulic oils)
2 Adjustment means Std setting 100 bar SV - Viton
F - Screw Adjustment (10:1): 100-210 bar. (For high temperature and
Cavity plug part number
Std setting 100 bar most special fluid applications)
35 - (2.5:1 and 5:1): 100-350 Nitrile
bar. Std setting 210 bar AXP13032-01-N
(10:1): 120-350 bar. Viton
Std setting 210 bar AXP13032-01-V
Std setting made at 4.8 L/min
Dimensions * Cartridges must not be adjusted above
the safe working pressure of the motor
mm (inch)
49.50 47.00 (1.85)
Complete Valve 1/2" Ports (1.95) approx 120.00 (4.72)
Basic Code: 1CEEOMP35 54.00 (2.13)

40.00
(1.57)
K V1
73.00 M1
18.00
(0.71)
(2.87) CT1
88.90
(3.50)
M2
CT2
V2

26.00
(1.02)
Tightening torque of “F”
adjuster locknut - 20 to 25 Nm
2 overcentre valves
1CE30-F**-*-* Note: For applications over 210 bar
Check motor mounting
(3000 psi), please consult our tech-
nical department or use the steel compatibility before
body option. specifying.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-84 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CEOMS95/1CEEOMS95 - Motor
mounted valves
OMS Mounting pattern single and dual overcenter valves

Pressure drop 4:1 Version 8:1 Version


Flow - L/min Flow - L/min
0 25 50 75 100 0 25 50 75 100
240 16 600 42
210 14 500 35

Pressure - bar
180

Pressure - psi
12

Pressure - bar
Pressure - psi
Free flow 400 28
150 10
Free flow
120 8 300 21
90 6
200 14
60 4
30 2 100 7
0 Piloted open 0 0 Piloted open 0
0 6.5 13 19.5 26 0 6.5 13 19.5 26
Flow - US gpm Flow - US gpm

code
Model –
1CE*OMS95-* F – 35 S 4 BK
4W

1
2 3 4 5 6 7

1 Basic code 3 Port size 6 Pilot ratio


1CEEOMS95 - Double Code V1 & V2 Brake Housing number 4 - 4:1
Cartridge and Body 4W 1/2" BSPP 1/4" BSPP BXP24055-4W-S 8 - 8:1
1CEOMS95-1 - Single
overcenter in line V1-M1 4 Pressure range 5 Seals 7 Mounting
1CEOMS95-2 - Single
Note: C
 ode based on S - Nitrile BK - Bolt Kit
overcenter in line V2-M2
pressure in bar. (For use with most industrial
20 - 70-225 bar. hydraulic oils)
2 Adjustment means SV - Viton
Std setting 100 bar Cavity plug part number
F - Screw Adjustment (For high temperature and Nitrile
35 - 200-350 bar. most special fluid applications)
Std setting 210 bar AXP14434-02-N
Dimensions Std setting made at 4.8 L/min Viton
* Cartridges must not be adjusted above AXP14434-02-V
mm (inch)
the safe working pressure of the motor

CT2 CT1

Complete Valve 1/2" Ports


Basic Code: 1CEEOMS95
24.00 66.00 (2.60)
62.00 (2.44) (0.94)

62.0 2 overcentre valves


1CE90-F**-*-*
(2.44)
approx K

V1 V2

Note: For applications over 210 bar


32.00 127.00 (3000 psi), please consult our
(1.26) (5.00) technical department or use the
91.00 steel body option.
(3.58)
M1
Tightening torque of “F”
adjuster locknut - 20 to 25 Nm
M2
Check motor mounting
42.00 35.00
21.00 compatibility before
(0.82)
(1.65) (1.38) specifying.
90.00 (3.54) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-85
1CESHOMP35/1CEESHOMP35 - Motor
mounted valves
OMP Mounting pattern single and dual overcenter valve with
brake release shuttle

M1 M2 M1 M2 M1 M2

CT1 CT2 CT1 CT2


CT3 CT3 CT3

V1 B1 B2 V2 V1 B1 B2 V2 V1 B1 B2 V2

1CESHOMP35-1 1CESHOMP35-2 1CEESHOMP35

Description Operation • The pressure required to Pilot ratios


Overcenter Valves give The check section allows open the valve and start 2.5:1 Best suited for
static and dynamic control free flow into the actuator actuator movement can be extremely unstable
of loads by regulating then holds and locks the load calculated as follows: applications such as
the flow into and out of against movement. The pilot long booms or flexible
hydraulic actuators. When assisted relief valve section Pilot Pressure = frameworks.
installed close to or within will give controlled movement (Relief Setting) - (Load Pressure) 5:1 Best suited for
an actuator, the overcenter when pilot pressure is applied. Pilot Ratio applications where
valve will stop runaway in The relief section is normally
load varies (Standard)
the event of hose burst and set to open at a pressure at
and machine structure
if open center directional least 1.3 times the maximum
can induce instability
control valves are used, will load induced pressure but the
allow thermal expansion pressure required to open the 10:1 Best suited for
relief of the hydraulic fluid. valve and allow movement applications where
depends on the pilot ratio of the load remains
These dual overcenter
the valve. For optimization relatively constant.
valves also contain a brake
release shuttle valve which of load control and energy
ensures that pressure is usage, a choice of pilot ratios
applied to a brake release is available.
circuit regardless of
whether pressure is applied
to ports V1 or V2. These Performance data
multifunction valves are
normally used for the static Ratings and specifications
and dynamic control of
Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
systems using motors or
semi-rotary actuators. Rated flow 30 L/min (8 USgpm)
Max setting Max load induced
Pressure:      270 bar (4000 psi)
Relief setting:   350 bar (5000 psi)
Cartridge material Working parts hardened & ground steel
External surface zinc plated
Body material Standard aluminium (up to 210 bar*)
Add suffix '377' for steel option
Mounting position Unrestricted
K Cavity Number A6610 (See section M)
Torque cartridge into cavity 45 Nm (33 ibs ft)
Weight 1CESHOMP35  2.29 kg  (5.04 lbs)
(inc cartridges) 1CEESHOMP35  2.34 kg  (5.15 lbs)
Seal kit number 1CESHOMP35  SK1285 (Nitrile)  SK1285V (Viton)
1CEESHOMP35  SK1284 (Nitrile)  SK1284V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-86 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CESHOMP35/1CEESHOMP35 - Motor
mounted valves
OMP Mounting pattern single and dual overcenter valve with brake
release shuttle
Pressure drop 2.5:1 & 5:1
Flow Version
- L/min 10:1 Version
0 10 20 30 40 50 Flow - L/min
750 50 0 10 20 30 40
750 50
600 40

Pressure - bar
Pressure - psi
600 40

Pressure - bar
Pressure - psi
450 30
Free flow 450 30
300 20 Free flow
300 20
150 10
Pilot 150
open 0 10
0 Pilot
0 2.5 5 7.5 10 12.5 0 open 0
Flow - US gpm 0 2.5 5 7.5 10
Flow - US gpm
code
Model 1CE*SHOMP35-* F
– 4W – 35 S 5 BK

2 3 4 5 6 7
1

1 Basic code 3 Port size 6 Pilot ratio


1CEESHOMP35 - Double Code V1 & V2 Brake Housing number 2 - 2.5:1
Cartridge and Body 4W 1/2" BSPP 1/4" BSPP BXP24053-4W-S 5 - 5:1
1CESHOMP35-1 - Single 10 - 10:1
overcenter in line V1-M1 4 Pressure range 5 Seals
1CESHOMP35-2 - Single 7 Mounting
Note: Code based on pressure S - Nitrile
overcenter in line V2-M2
in bar. (For use with most industrial BK - Bolt Kit
20 - (2.5:1 and 5:1): 70-210 bar. hydraulic oils)
2 Adjustment means Std setting 100 bar SV - Viton
F - Screw Adjustment (10:1): 100-210 bar. (For high temperature and
Std setting 100 bar most special fluid applications)
35 - (2.5:1 and 5:1): 100-350 Cavity plug part number
bar. Nitrile
Std setting 210 bar AXP13032-01-N
(10:1): 120-350 bar.
Std setting 210 bar Viton
Std setting made at 4.8 L/min AXP13032-01-V
Dimensions * Cartridges must not be adjusted above
the safe working pressure of the motor
mm (inch) 101.60 (4.00)
54.0 (2.13) 4 mtg holes
Complete Valve 1/2" Ports 22.0
(0.87)
27.0
(1.06)
Ø9.00 (0.35) through
C'bored Ø14.00 (0.55) x 10.00 (0.39)
18.0
Basic Code: 1CEESHOMP35 (0.71) deep

Note: For applications over 210 bar BR2 20.0 20.0


(3000 psi), please consult our tech- (0.79) BR1 (0.79)
nical department or use the steel
body option. 28.0
(1.10)
28.0
(1.10) 110.0
K
(0.43)
20.0
M2
(0.79)
CT3 36.0
(1.42)
20.0
V2 V1 (0.79)

2 overcentre valves
1CE30-F**-*-*

Tightening torque of “F” 63.0 (2.48)


40.0
(1.57)
36.0
(1.42)
adjuster locknut - 20 to 25 Nm

Check motor mounting CT2


compatibility before
specifying. CT1

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-87
1CESHOMS95/1CEESHOMS95 - Motor
mounted valves
OMS Mounting pattern single and dual overcenter valves with brake
release shuttle
M1 M2 M1 M2 M1 M2

CT1 CT2 CT1 CT2


CT3 CT3 CT3

V1 B1 B2 V2 V1 B1 B2 V2 V1 B1 B2 V2

1CESHOMS95-1 1CESHOMS95-2 1CEESHOMS95

Description Operation The pressure required to open Pilot ratios


Overcenter Valves give The check section allows the valve and start actuator 4:1 Best suited for
static and dynamic control free flow into the actuator movement can be calculated applications where
of loads by regulating the then holds and locks the load as follows: load varies and
flow into and out of hydraulic against movement. The pilot machine structure can
actuators. When installed assisted relief valve section Pilot Pressure = induce instability
close to or within an actuator, will give controlled movement (Relief Setting) - (Load Pressure) 8:1 Best suited for
the overcenter valve will when pilot pressure is applied. Pilot Ratio applications where
stop runaway in the event The relief section is normally
the load remains
of hose burst and if open set to open at a pressure at
relatively constant.
center directional control least 1.3 times the maximum
valves are used, will allow load induced pressure but the Other ratios available
thermal expansion relief of the pressure required to open the upon request
hydraulic fluid. valve and allow movement
These dual overcenter depends on the pilot ratio of
valves also contain a brake the valve. For optimization
release shuttle valve which of load control and energy
ensures that pressure is usage, a choice of pilot ratios
applied to a brake release is available.
circuit regardless of whether
pressure is applied to ports
V1 or V2. These multifunction
valves are normally used for Performance data
the static and dynamic control
of systems using motors or Ratings and specifications
semi-rotary actuators. Figures based on: Oil Temp = 40°C Viscosity = 32 cSt (150 SUS)
Rated flow 90 L/min (23 USgpm)
Max setting Max load induced
Pressure:       270 bar (4000 psi)
Relief setting:   350 bar (5000 psi)
Cartridge material Working parts hardened & ground steel
External surface zinc plated
Body material Standard aluminium (up to 210 bar*)
Add suffix '377' for steel option
Mounting position Unrestricted
Cavity Number A12336 (See section M)
Torque cartridge into cavity 60 Nm (44 ibs ft)
K Weight 1CESHOMS95  2.32 kg  (5.10 lbs)
(inc cartridges) 1CEESHOMS95  2.42 kg  (5.32 lbs)
Seal kit number 1CESHOMS95  SK1282 (Nitrile)  SK1282V (Viton)
1CEESHOMS95  SK795 (Nitrile)  SK795V (Viton)
Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
Operating Temp -30°C to +90°C (-22° to 194°F)
Leakage 0.3 milliL/min nominal (5 dpm)
Nominal viscosity range 5 to 500 cSt

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

K-88 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
1CESHOMS95/1CEESHOMS95 - Motor
mounted valves
OMS Mounting pattern single and dual overcenter valves with brake
release shuttle
4:1 Version 8:1 Version
Pressure drop Flow - L/min Flow - L/min
0 25 50 75 100 0 25 50 75 100
240 16 600 42
210 14 500 35

Pressure - bar
180

Pressure - psi
12

Pressure - bar
Pressure - psi
Free flow 400 28
150 10
Free flow
120 8 300 21
90 6
200 14
60 4
30 2 100 7
0 Piloted open 0 0 Piloted open 0
0 6.5 13 19.5 26 0 6.5 13 19.5 26
Flow - US gpm Flow - US gpm

code
Model 1CE*SHOMS95-* F
– 4W – 35 S 4 BK

1 2 3 4 5 6 7

1 Basic code 3 Port size 6 Pilot ratio


1CEESHOMS95 - Double Code V1 & V2 Brake Housing number 4 - 4:1
Cartridge and Body 4W 1/2" BSPP 3/8" BSPP BXP24056-4W-S 8 - 8:1
1CESHOMS95-1 - Single
overcenter in line V1-M1 4 Pressure range 7 Mounting
1CESHOMS95-2 - Single 5 Seals
Note: Code based on BK - Bolt Kit
overcenter in line V2-M2 S - Nitrile (For use with most
pressure in bar.
industrial hydraulic oils)
20 - 70-225 bar. Std setting
2 Adjustment means SV - Viton
100 bar
(For high temperature and Cavity plug part number
F - Screw Adjustment 35 - 200-350 bar. Std setting most special fluid applications) Nitrile
210 bar AXP14434-02-N
Std setting made at 4.8 L/min Viton
* Cartridges must not be adjusted above AXP14434-02-V
the safe working pressure of the motor

Dimensions
mm (inch) B

Complete Valve 1/2" Ports 13.50


(0.53)
Basic Code: 1CEESHOMS35
CT2 CT1
45.00
(1.77)
Note: For applications over 210 bar 62.00 (2.44) 24.00 (0.94)
66.00 (2.60)
(3000 psi), please consult our tech-
nical department or use the steel K
body option. 62.0 2 overcentre
(2.44) valves
approx 1CE90-F**-*-*

V1 V2

32.00 127.00
(1.26) (5.00)
CT3
91.00
(3.58)
M1
Tightening torque of “F”
adjuster locknut - 20 to 25 Nm M2

Check motor mounting 42.00


(1.65)
35.00
(1.38)
21.00
(0.83)
compatibility before 90.00 (3.54)
specifying.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com K-89
- Additional products, product lines, and services offered by Eaton -

Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com

Вам также может понравиться