Вы находитесь на странице: 1из 20

ByAcademy

Technical Training

Installation Bysoft 6.x

Issue date: 03.2011

05_02_InstallationBysoftComponents_V03A_en.doc © Bystronic Laser AG, 2011


ByAcademy
Technical Training

Contents

1 Installation .......................................................... 5
1.1 System requirements.................................................. 5
1.2 System permissions .................................................... 5
1.3 Core software modules (flat parts, tubular parts,
administration) ....................................................... 6
1.3.1 Installing the core software modules ................................ 6
1.3.2 Bysoft database............................................................. 7
1.4 Bending modules ........................................................ 8
1.4.1 Installing the bending modules ........................................ 8
1.5 3rd-party modules ...................................................... 9
1.5.1 Installing the 3rd-party modules ...................................... 9
2 Update ............................................................... 10
2.1 System permissions .................................................. 10
2.2 Core software modules (flat parts, tubular parts,
administration) ..................................................... 11
2.2.1 Bysoft database backup ................................................ 11
2.3 Updating the core software modules ........................ 13
2.4 Bending modules ...................................................... 14
2.4.1 BOS database backup .................................................. 14
2.4.2 Updating the bending modules ...................................... 15
2.4.3 Updating the machine software ..................................... 16
2.5 3rd-party modules .................................................... 17
3 Service packs..................................................... 18
3.1 System permissions .................................................. 18
3.2 Bysoft service pack ................................................... 18
3.3 BOS Base / MMC Bybend .......................................... 20

© Bystronic Laser AG, 2011 3


ByAcademy
Technical Training

1 Installation

1.1 System requirements

Recommended system requirements for the PC for Bysoft 6.x:

- Microsoft Windows 2000, XP, Vista or 7 operating system


- 3 GHz or faster CPU processor
- 2 GB RAM
- 1 GB available hard disk space (excluding Bysoft database)
- Graphics card with 64 MB VRAM and OpenGL compatibility
- 1280 x 1024 pixel monitor
- CD drive
- Mouse (three buttons and scroll wheel)
- Keyboard

1.2 System permissions

The following local Windows system permissions are required in order to


install and use Bysoft 6:

Function Permission
Installation Local administrator

Operation Local user

© Bystronic Laser AG, 2011 5


ByAcademy
Technical Training

1.3 Core software modules (flat parts, tubular parts,


administration)

The core software contains all the modules required for administration
and machining flat parts and tubular parts:

- Bybase - Byparam
- Bypart - Byview
- Bywork - Byorder
- Bytubepart - Bysort
- Bytubework - BYDBA
- Byconvert - TAR Editor

1.3.1 Installing the core software modules

Please use the correct Bysoft installation CD to ensure you install the
correct version of Bysoft.

Installation:

1. Bysoft 6.x.x

2. License Manager

Please follow the installation instructions on the screen and use


the default installation directories:

Bysoft -> C:\Program Files\Bysoft6


License Manager -> C:\Program Files\Bystronic\LicenseManager

Please note:
The core software modules must always be installed.

6 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

Please note:
Instructions on how to install and activate the License
Manager are given in a separate document.

1.3.2 Bysoft database

As soon as several workstations are installed with Bysoft 6 it makes


sense to share the Bysoft database in order to work with the same data
for all users.
Therefore the local installed database, partroot and workroot
directories have to be copied to a server or a shared network drive (e.g.
“X\bystronic”). Next the Bysoft 6 configuration file (bysoft6.ini) has to
be modified on all workstations in order to point to the database on the
server/network drive.
The bysoft6.ini can be found in the following directories:

Windows XP Bysoft 6.0.0 – 6.8.1

“C:\WINDOWS”

Windows XP Bysoft 6.8.2 - …

“C:\Documents and Settings\All Users\Application Data\Bystronic\Bysoft6”

Windows 7 Bysoft 6.8.2 - …

“C:\ProgramData\Bystronic\Bysoft6”

Modification of the datapath’s:


DBFilename= …
Partroot= …
Workroot= …
ParamDBPath= …

As an option the reports and techchnology wizard can be shard as well if


you also copy the reports and techassist directory and modify the
datapath’s for ReportRoot= and TechassistDir= .

© Bystronic Laser AG, 2011 7


ByAcademy
Technical Training

1.4 Bending modules

The bending software contains all the modules for 3D/2D bending-part
design and bending technology. These are additional modules to the core
software:

- Designer / Unfolder - BOS Base


- Bybendpart

1.4.1 Installing the bending modules

Installation:

1. Bending Object Services

2. 3rd-party programs

3. Designer / Unfolder

Please follow the installation instructions on the screen and use


the default installation directories:

BOS Base -> C:\Program Files\Bending


Designer / Unfolder -> C:\Program Files\Bysoft6\programs

8 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

1.5 3rd-party modules

The 3rd-party program modules contain software from third-party


providers that is distributed by Bystronic:

- Logitrace - NC Converter

1.5.1 Installing the 3rd-party modules

Logitrace

1. 3rd-party programs

2. HVAC Logitrace

NC Converter

1. 3rd-party programs

2. NC Converter

Please follow the installation instructions on the screen and use


the default installation directories:

Logitrace -> C:\Program Files\Logitrace_Vxx


NC Converter -> C:\Program Files\Control Software AG

© Bystronic Laser AG, 2011 9


ByAcademy
Technical Training

2 Update

This section explains how to update an existing Bysoft 6 installation to a


newer version.

Please note:
Bystronic strongly recommends performing a Bysoft and
BOS database backup before EVERY update.

2.1 System permissions

The following local Windows system permissions are required in order to


update Bysoft 6:

Function Permission
Update Local administrator

10 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

2.2 Core software modules (flat parts, tubular parts,


administration)

2.2.1 Bysoft database backup

Bystronic strongly recommends performing a Bysoft database backup


before the update.
The Bysoft database essentially contains the Database, Partroot and
Workroot folders.
The best way to find out the backup location of these folders is to open
the bysoft6.ini file, which is located under the following datapath’s:

Windows XP Bysoft 6.0.0 – 6.8.1

“C:\WINDOWS”

Windows XP Bysoft 6.8.2 - …

“C:\Documents and Settings\All Users\Application Data\Bystronic\Bysoft6”

Windows 7 Bysoft 6.8.2 - …

“C:\ProgramData\Bystronic\Bysoft6”

1.
Open the bysoft6.ini file using a
text editor (e.g. Windows Notepad)

2.
Look in the [Directories] section
to find the backup paths of the
database folders

© Bystronic Laser AG, 2011 11


ByAcademy
Technical Training

3.
Use Windows Explorer to open the
backup paths and create a backup
of the folders.

Please note:
If working documents or Technology Wizards have been
modified to work with, it is best to back up the reports and
techassist folders as well.

12 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

2.3 Updating the core software modules

Please use the correct Bysoft installation CD to ensure you install the
correct version of Bysoft.
The installation procedure for the update is the same as for a new
installation (see page 6), although the following points should be
noted:

During the update, Bysoft may want to install the software in a new
folder (e.g. “C:\Program Files\Bysoft6_2”).
To avoid working with more than one version of Bysoft by mistake, it is
best to change the installation folder to the standard default folder:
Bysoft -> C:\Program Files\Bysoft6

Please note:
The database folders database, partroot and workroot
are not changed during the update.
All the other folders for reports and techassist are
overwritten.

© Bystronic Laser AG, 2011 13


ByAcademy
Technical Training

2.4 Bending modules

2.4.1 BOS database backup

Bystronic strongly recommends performing a BOS database backup


before the update.
The BOS database contains the bosdict, components, repository and
system folders.
The best way to find out the backup location of these folders is to open
the “BOS database configuration” program, which is located in:
C:\Program files\Bending\programs\BOSDBA.exe

1.
Open the BOSDBA.exe program

2.
Look in the Configuration
section to find the backup paths
of the database folders

3.
Use Windows Explorer to open the
backup paths and create a backup
of the folders.

Please note:
As an extra safeguard, Bystronic recommends using the
BOS Administrator program and its XML Export Wizard
to export the entire machine configuration including
backgauge fingers, tools and material curves.

14 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training
2.4.2 Updating the bending modules

Please use the correct Bysoft installation CD to ensure you install the
correct version of Bysoft.
The installation procedure for the update is the same as for a new
installation (see page 8), although the following points should be
noted:

In the Update process, it is best to select the option “use existing BOS
database” in order to continue using the existing bending data.

Once the installation has finished, the old BOS database contents must
be updated:

Run the BOS database


configuration program and
update the BOS Base:
Update database

© Bystronic Laser AG, 2011 15


ByAcademy
Technical Training

2.4.3 Updating the machine software

When updating the Bysoft bending modules, it is sometimes also


necessary to update the MMC Bybend machine software, if its BOS Base
version is older than that installed in the Bysoft workstations.
The following table shows the compatibility of MMC Bybend, Bysoft, BOS
Base and Designer/Unfolder:

MMC Bybend Bysoft BOS Base Designer/Unfolder

7.6.0 Xpert/Hämmerle 3P
6.8.2 7.6.0 01.21.0004
2.9.0 Hämmerle P21

7.5.0 Xpert/Hämmerle 3P
6.8.1 7.5.0 01.20.0003
2.8.0 Hämmerle P21

7.4.0 Xpert/Hämmerle 3P
6.8.0 7.4.0 01.18.0011
2.7.0 Hämmerle P21

7.3.0 Xpert
6.7.5 7.3.0 01.18.0001
2.6.0 Hämmerle P21

7.2.0 Xpert
6.7.4 7.2.0 01.18.0001
2.5.0 Hämmerle P21

7.1.0 Xpert 7.1.0


6.7.3 01.16.0001
2.4.2 Hämmerle P21 2.4.2

2.4.2 6.7.2 2.4.2 01.16.0001

2.4.1 6.7.1 2.4.1 01.14.0005

2.4.0 6.7.0 2.4.0 01.14.0005

2.3.0 6.6.2 2.3.0 01.14.0004

2.2.0 6.6.1 2.2.0

2.1.x 6.6.0 2.1.x

Please note:
This document does not explain how to update the MMC
Bybend machine software, because there is a separate
document written expressly for this procedure.

16 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

2.5 3rd-party modules

The procedure for updating the “Logitrace” and “NC Converter” third-
party modules is identical to that for a new installation (see page 9).

© Bystronic Laser AG, 2011 17


ByAcademy
Technical Training

3 Service packs

Minor changes and fixes are usually dealt with by providing free service
packs. We issue separate service packs for Bysoft and BOS Base/MMC
Bybend.

Please note:
Service packs are sent directly from Bysoft Support to the
relevant branch office on request (e.g. by email or
Bystronic ticket download).

3.1 System permissions

The following local Windows system permissions are required in order to


install a Bysoft 6 service pack:

Function Permission
Service pack installation Local administrator

3.2 Bysoft service pack

This section describes how to install a Bysoft service pack:

1.
Save the service pack locally on
the PC and select the correct
language folder.

The readme.txt file contains


information on the changes/fixes
contained in the service pack

18 05_02_InstallationBysoftComponents_V03A_en.doc
ByAcademy
Technical Training

2.
Select the entire contents of the
folder and copy to the clipboard

3.
Paste the copied files into the
Programs directory of the Bysoft6
installation folder, overwriting the
existing files.

Default:
“C:\Program
Files\Bysoft6\programs”

Please note:
There is no automatic setup for the Bysoft service packs, so
they need to be “installed” using copy and paste. Usually
there are just a few files involved, which can easily be
copied.

© Bystronic Laser AG, 2011 19


ByAcademy
Technical Training

3.3 BOS Base / MMC Bybend

This section describes how to install a BOS Base / MMC Bybend service
pack:

1.
Save the service pack locally on
the PC.

2.
Select the entire contents of the
folder and copy to the clipboard

The readme.txt file contains


information on the changes/fixes
contained in the service pack and
any extra installation instructions.

3.
Paste the copied files into the
Programs directory of the Bending
installation folder, overwriting the
existing files.

Default:
“C:\Program
Files\Bending\programs”

Please note:
There is no automatic setup for the BOS Base / MMC
Bybend service packs, so they need to be “installed” using
copy and paste. Usually there are just a few files involved,
which can easily be copied.

20 05_02_InstallationBysoftComponents_V03A_en.doc