Вы находитесь на странице: 1из 8

Ref. No.

MHSB/QC/ARCH/01/008

Description
Architectural Work Inspection Form
EXTERNAL

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
EXTERNAL 1. Corners of wall maintained at right angels
Alignment

Plaster finish 1. No visible cracks across panels

2. Surfaces should be visually even; no patches due to


patching work

3. Straightness of corners

Tiled finish 1. Tile joints aligned and between 2-4mm wide unless
specified

2. Plumb tolerance and evenness of surface (3mm/1.2mm)

3. No chips, cracks and mortar stains

4. No mortar dropping or paint drip on tiles

Claddings/Curtain 1. Gaps araound openings to be properly sealed


walls
2. Joints or regular widths as specified

3. Plumb tolerance as specified

4. Evenness of surface, no dents or scratches

5. Sealant material compatible with cladding

Facing Brickwork 1. 10mm joint with pointing

2. Weepholes are provided as specified

3. No mortar droppings and other stains

4. No efflorescene
Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
Architectural Coating 1. Substrate - see plaster finish

2. Finished texture and colour to be uniform

3. No paint drips and other stains

Painting 1. Substrate - see plaster finish

2. Surfaces are evenly painted: no patchness due to


touch up work

3. Good opacity, no discolouring and free from peeling

Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :
Ref. No. MHSB/QC/ARCH/01/009

Description
Architectural Work Inspection Form
APRONS AND DRAINS

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
APRONS AND 1. Free flowing and no ponding of water
DRAINS
Drains 2. No stains and mortar droppings

3. Drain covers must be level and do not warp or rock

4. Gaps between drain covers and side of drain between


5-10mm wide

5. Drain grating properly painted

6. Hairline cracks not wider tan 0.5mm

7. Precast sections not chipped or damaged

Aprons 1. Bitumen joints with neat edges and sufficient length

2. No stains and mortar dropping

3. Cracks, maximum 05.mm wide, 0.5 long

4. No ponding

Inspection chambers 1. Inspection chambers are level with surrounding without


depression and with tolerance of 20mm for protrusion
2. Covers to be level with frames and within 5mm tolerance

Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :

Ref. No. MHSB/QC/ARCH/01/010

Description
Architectural Work Inspection Form
ROADS AND CARPARK

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
ROADS AND 1. Free flowing and no ponding of water
CARPARK
Side Drains 2. No stains and mortar droppings

3. Drain covers must be level and do not warp or rock

4. Gaps between drain covers and side of drain between


5 - 10mm wide

5. Drain grating properly painted

6. Hairline cracks not wider than 0.5mm

7. Precast sections not chipped or damaged

Road surface 1. No ponding

2. Road painting according to drawings, dimensional


tolerance of 5mm

Kerbs and aeration 1. Kerbs with correct alignment (20mm/50mm long) and
slabs evenness at joints

2. No stains, mortar droppings or chipped


3. Aeration slabs stable and not broken

4. Gaps between aerations labs properly filled up with


sand

Road signs 1. Provided accrding to specifications

2. Film and sucured at base

3. Sign posts painted evenly goos opacity achieve

4. No corrosion

Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :

Ref. No. MHSB/QC/ARCH/01/011

Description
Architectural Work Inspection Form
FOOTPATHS AND TURFING

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
FOOTPATHS AND 1. Foothpaths with even surface and neat edges
TURFING
Foothpaths 2. No stain and mortar droppings

3. Cracks must not exceed 0.5mm

Turfing 1. No depression or bald patches

2. Turfing done evenly, no dead grass or weeds


Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :

Ref. No. MHSB/QC/ARCH/01/012

Description
Architectural Work Inspection Form
FENCES AND GATES

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
FENCES AND 1. According to survey boundry
GATES
Fences and Gates 2. Railings and metal supports are galvanished or
properly painted

3. Fencing is PVC covered

4. Footings provided for supports

5. Vertical tolerance (4mm/1.2m)


Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :

Ref. No. MHSB/QC/ARCH/01/013

Description
Architectural Work Inspection Form
OTHER EXTERNAL WORKS

Name : Location :

Drawing Ref. :

Date :

Acceptability
ITEMS ITEMS TO BE CHECKED Contractor JKR Remark
Yes No Yes No
OTHER EXTERNAL 1. Constructed according to Contract Specifications
WORKS
(Include playground, 2. For permanent fixtures which are not covered in the
swimming pools, standards, the fundamental rules for installation and
fitness corner and workmanship such as evenness, straightness,
loadings bay) vertically and consistency will still be the basis for
assessment

Verified by : Checked / Approved by :

COW / R. Engineer

Date : Date :