BTS Power Management Feature


Parameter Description

Issue 01
Date 2012-04-28

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Issue 01 (2012-04-28) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description Contents

Contents

1 About This Document..................................................................................................................1


1.1 Scope..................................................................................................................................................................1
1.2 Intended Audience..............................................................................................................................................1
1.3 Change History...................................................................................................................................................1

2 Overview.........................................................................................................................................3
3 Technical Description...................................................................................................................4
3.1 Hierarchical Power-off.......................................................................................................................................5
3.2 Voltage Abnormal Protection.............................................................................................................................5

4 Engineering Guidelines...............................................................................................................6
4.1 Support of Hierarchical Power-off.....................................................................................................................6
4.2 Support of Voltage Abnormal Protection...........................................................................................................6

5 Parameters.......................................................................................................................................7
6 Counters........................................................................................................................................14
7 Glossary.........................................................................................................................................15
8 Reference Documents.................................................................................................................16

Issue 01 (2012-04-28) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 1 About This Document

1 About This Document

1.1 Scope
This document describes the BTS Power Management feature. It mainly covers the two basic
functions provided by the BTS Power Management feature, that is, hierarchical power-off and
voltage abnormal protection.

The feature involved is GBFD-111601 BTS Power Management.

1.2 Intended Audience


This document is intended for:

l Personnel who need to understand the BTS Power Management feature


l Personnel who work with Huawei products

1.3 Change History


This section provides information on the changes in different document versions.

There are two types of changes, which are defined as follows:

l Feature change: refers to the change in the BTS Power Management feature of a specific
product version.
l Editorial change: refers to the change in wording or the addition of the information that
was not described in the earlier version.

Document Issues
The document issues are as follows:

l 01 (2012-04-28)
l Draft A (2012-02-15)

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 1 About This Document

01 (2012-04-28)
This is the first commercial release of GBSS14.0.
Compared with issue Draft A (2012-02-15), issue 01 (2012-04-28) has no change.

Draft A (2012-02-15)
This is the draft A release of GBSS14.0.
Compared with issue 01 (2011-03-31) of GBSS13.0, issue Draft A (2012-02-15) of GBSS14.0
has no change.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 2 Overview

2 Overview

BTS Power Management supports hierarchical power-off and voltage abnormal protection. The
BTS Power Management feature enhances power management and self-protection of the BTS,
thus improving the reliability of the system and prolonging the lifespan of products and the
serving time of the system. With this feature, the BTS stability is improved, thus improving the
Quality of Service (QoS). In addition, the O&M cost for the BTS is cut, thus indirectly increasing
the revenue of operators.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 3 Technical Description

3 Technical Description

The BTS hierarchical power-off function takes effect when there is no mains supply available.
This function aims at reducing the power consumption of the BTS equipment and thus extends
the discharge time of the battery. In addition, the BTS hierarchical power-off function can also
prevent over-discharging of the battery.
The BTS hierarchical power-off function also takes effect when the working environment in the
BTS cabinet is severe, for example, when the temperature inside the BTS cabinet exceeds the
predefined thresholds or when the Voltage Standing Wave Ratio (VSWR) far exceeds the limits.
In such cases, the system automatically shuts down the Power Amplifiers (PAs) for some TRXs
to reduce the heat consumption.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 3 Technical Description

3.1 Hierarchical Power-off


When there is no mains supply available, the BTS hierarchical power-off function is performed
to reduce the power consumption and extend the discharge time of the battery. In this case, the
system automatically blocks all TRXs, except the BCCH TRX. This is called a soft shutdown.
When the capacity of the battery drops to the preset value, the system automatically shuts down
all the TRXs to prevent over-discharging of the battery. This is called a hard shutdown. Whether
to use automatic power-off is configurable. The hierarchical power-off function especially suits
the cascaded BTSs. When the mains power of the upper-level BTS is disconnected and the mains
power of the lower-level BTS is normal, this function can be used to prolong the working time
of the transmission module of the upper-level BTS to reduce the impact on the lower-level BTS.

3.2 Voltage Abnormal Protection


When the working environment is severe or the temperature regulation unit does not work
properly, the TMU shuts down the PAs for some TRXs to reduce the heat consumption if the
temperature inside the cabinet exceeds the predefined thresholds. This prevents any negative
impact on the system. If the TRX is faulty or the VSWR far exceeds the limits, the TRX is made
out-of-service and is shut down. The PA for the TRX is also shut down. This is to minimize the
possibility of total damage. Whether to use this function and the related parameters to be used
for this function are configurable. In this manner, the flexibility of the system is improved.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 4 Engineering Guidelines

4 Engineering Guidelines

4.1 Support of Hierarchical Power-off


The SET BTSAPMUBP command is executed on the LMT to enable the hierarchical power-
off function. Note that the CFGFLAG parameter must be set to YES(YES) to enable the
configuration of other parameters. The HPVFLAG parameter is set to YES(YES), which
indicates that the hierarchical power-off function is enabled. The LSDV parameter is set to
440, which is the threshold of the battery capacity. When the battery capacity drops to a value
smaller than 440, a hard shutdown is performed. Note that the LSDV parameter is set to 475
when the PTYPE parameter is set to SC48200(SC48200), and that the LSDV parameter is
always set to 4294967295 (equals to the hexadecimal number FFFFFFFF) and cannot be
modified when the PTYPE parameter is set to EPS4815(EPS4815). One is advised to set the
LSDV parameter to 440 when the PTYPE parameter is set to values other than SC48200
(SC48200) and EPS4815(EPS4815).The LSDF parameter is set to ENABLE(ENABLE),
which indicates that the hard shutdown function is validated.

4.2 Support of Voltage Abnormal Protection


The SET BTSAPMUBP command is executed on the LMT to enable the voltage abnormal
protection function. Note that the CFGFLAG parameter must be set to YES(YES) to enable the
configuration of other parameters. The HIGHTEMPLOADPWROFF parameter is set to YES
(YES), which indicates that the PA for the TRX will be shut down when the temperature rises
to a high value. The ENDHEATTEMP parameter is set to 52, which indicates that the PA for
the TRX is shut down only when the temperature inside the cabinet reaches 52°C. The PA is
automatically shut down when the VSWR far exceeds the limits or the TRX is faulty. Therefore,
the PA shutdown function does not need to be configured for these two cases.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

5 Parameters

Table 5-1 Parameter description


Parameter ID NE MML Feature ID Feature Name Description
Command

CFGFLAG BSC6900 SET GBFD-111202 O&M of BTS Meaning:Wheth


BTSAPMUBP er to allow the
configuration of
board
parameters. The
value "YES"
indicates that the
configuration is
allowed, and the
value "NO"
indicates that the
configuration is
not allowed. In
multi-mode
scenario, the
value of this
parameter in this
mode must be
the same as the
value of the
corresponding
parameter in
another mode.
GUI Value
Range:NO
(NO), YES
(YES)
Unit:None
Actual Value
Range:NO, YES

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

Default
Value:None

ENDHEATTE BSC6900 SET GBFD-111202 O&M of BTS Meaning:If the


MP BTSDHEUBP ambient
temperature
reaches the
value of this
parameter, the
heater is shut
down. In multi-
mode scenario,
the value of this
parameter in one
mode must be
the same as the
value of the
corresponding
parameter in
another mode.
GUI Value
Range:-990~40
0
Unit:0.1degree
Celsius
Actual Value
Range:-99.0~40
.0
Default Value:0

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

HIGHTEMPL BSC6900 SET GBFD-111202 O&M of BTS Meaning:Wheth


OADPWROFF BTSAPMUBP er to enable load
power-off
against high
temperature.
BTS3006C and
BTS3002E
support this
parameter while
DBS3900 GSM,
BTS3900A
GSM,
BTS3900AL
GSM, BTS3900
GSM,
BTS3900L
GSM,
DBS3036,
BTS3036A,
BTS3036, and
BTS3900E
GSM do not
support this
parameter.
GUI Value
Range:NO
(NO), YES
(YES)
Unit:None
Actual Value
Range:NO, YES
Default
Value:YES
(YES)

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

HPVFLAG BSC6900 SET GBFD-111202 O&M of BTS Meaning:Wheth


BTSAPMUBP GBFD-111601 BTS Power er to enable the
Management configuration of
power system
parameters. In
multi-mode
scenario, the
value of this
parameter in one
mode must be
the same as the
value of the
corresponding
parameter in
another mode.
GUI Value
Range:NO
(NO), YES
(YES)
Unit:None
Actual Value
Range:NO, YES
Default
Value:NO(NO)

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

LSDF BSC6900 SET GBFD-111202 O&M of BTS Meaning:The


BTSAPMUBP Load Shutdown
Flag parameter
under this
command
specifies
whether to shut
down secondary
loads (for
example, TRXs)
when the direct
current (DC)
voltage of a base
station is low. If
secondary loads
are shut down,
they stop
working but
primary loads
(for example,
transmission
and main control
boards) continue
working
properly. If the
base station is of
multi-mode, the
value of this
parameter must
be the same for
different modes.
GUI Value
Range:DISABL
E(DISABLE),
ENABLE
(ENABLE)
Unit:None
Actual Value
Range:DISABL
E, ENABLE
Default
Value:DISABL
E(DISABLE)

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

LSDV BSC6900 SET GBFD-111202 O&M of BTS Meaning:Load


BTSAPMUBP power-off
voltage
threshold. If
"Load
Shutdown Flag"
is set to "Enable"
and the load
voltage is lower
than the value of
this parameter,
TRX modules is
automatically
powered off. In
multi-mode
scenario, the
value of this
parameter in one
mode must be
the same as the
value of the
corresponding
parameter in
another mode.
GUI Value
Range:350~556
Unit:0.1V
Actual Value
Range:
35.0~55.6
Default Value:
450

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 5 Parameters

Parameter ID NE MML Feature ID Feature Name Description


Command

PTYPE BSC6900 SET GBFD-111202 O&M of BTS Meaning:Power


BTSAPMUBP type. When the
PMU is installed
on the rack, you
can select the
custom power
type. In multi-
mode scenario,
the value of this
parameter in one
mode must be
the same as the
value of the
corresponding
parameter in
another mode.
GUI Value
Range:APM100
(APM100),
APM200
(APM200),
APM30
(APM30),
EPS4890
(EPS4890),
EPS4815
(EPS4815),
SC48200
(SC48200),
DPMU
(DPMU), ETP
(ETP),
CUSTOM
(CUSTOM)
Unit:None
Actual Value
Range:APM100
, APM200,
APM30,
EPS4890,
EPS4815,
SC48200,
CUSTOM,
DPMU, ETP
Default
Value:APM100
(APM100)

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 6 Counters

6 Counters

There are no specific counters associated with this feature.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 7 Glossary

7 Glossary

For the acronyms, abbreviations, terms, and definitions, see the Glossary.

Issue 01 (2012-04-28) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
GSM BSS
BTS Power Management Feature Parameter Description 8 Reference Documents

8 Reference Documents

1. BSC6900 Feature List


2. BSC6900 Basic Feature Description
3. BSC6900 GSM Parameter Reference
4. BSC6900 GSM MML Command Reference