Академический Документы
Профессиональный Документы
Культура Документы
GBSS14.0
Issue 01
Date 2012-04-28
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
2 Overview.........................................................................................................................................3
3 Technical Description...................................................................................................................4
3.1 Hierarchical Power-off.......................................................................................................................................5
3.2 Voltage Abnormal Protection.............................................................................................................................5
4 Engineering Guidelines...............................................................................................................6
4.1 Support of Hierarchical Power-off.....................................................................................................................6
4.2 Support of Voltage Abnormal Protection...........................................................................................................6
5 Parameters.......................................................................................................................................7
6 Counters........................................................................................................................................14
7 Glossary.........................................................................................................................................15
8 Reference Documents.................................................................................................................16
1.1 Scope
This document describes the BTS Power Management feature. It mainly covers the two basic
functions provided by the BTS Power Management feature, that is, hierarchical power-off and
voltage abnormal protection.
l Feature change: refers to the change in the BTS Power Management feature of a specific
product version.
l Editorial change: refers to the change in wording or the addition of the information that
was not described in the earlier version.
Document Issues
The document issues are as follows:
l 01 (2012-04-28)
l Draft A (2012-02-15)
01 (2012-04-28)
This is the first commercial release of GBSS14.0.
Compared with issue Draft A (2012-02-15), issue 01 (2012-04-28) has no change.
Draft A (2012-02-15)
This is the draft A release of GBSS14.0.
Compared with issue 01 (2011-03-31) of GBSS13.0, issue Draft A (2012-02-15) of GBSS14.0
has no change.
2 Overview
BTS Power Management supports hierarchical power-off and voltage abnormal protection. The
BTS Power Management feature enhances power management and self-protection of the BTS,
thus improving the reliability of the system and prolonging the lifespan of products and the
serving time of the system. With this feature, the BTS stability is improved, thus improving the
Quality of Service (QoS). In addition, the O&M cost for the BTS is cut, thus indirectly increasing
the revenue of operators.
3 Technical Description
The BTS hierarchical power-off function takes effect when there is no mains supply available.
This function aims at reducing the power consumption of the BTS equipment and thus extends
the discharge time of the battery. In addition, the BTS hierarchical power-off function can also
prevent over-discharging of the battery.
The BTS hierarchical power-off function also takes effect when the working environment in the
BTS cabinet is severe, for example, when the temperature inside the BTS cabinet exceeds the
predefined thresholds or when the Voltage Standing Wave Ratio (VSWR) far exceeds the limits.
In such cases, the system automatically shuts down the Power Amplifiers (PAs) for some TRXs
to reduce the heat consumption.