Вы находитесь на странице: 1из 5

2/2 Logic Cartridge Valve, Size 16

Passive Control, Seated Design, Soft Switching


Series WL22SDUR ...

S 350 l/min, 420 bar trolled valves with the 2 switched posi-
S Area ratio 2 : 1 tions "ON" and "OFF", 2 main ports 1
S High flow rates with low Δp and 2, a pilot port 3, and a closing
S Seat−valve shut−off from spring. A passive control system is inte-
1 → 2 and 2 → 1 grated in the seated valve spool.
S Glide seal on the seated valve spool Spool damping has been incorporated
S Various opening pressures to provide soft−switching.
S Orifice for pilot port is integrated in All external parts are chromited (Cr VI−
the cartridge free) and are thus suitable for use in the
S all external parts are chromited and harshest operating environments.
are Cr VI−free For customers who manufacture their
S Can be fitted in a line−mounting body own manifold blocks, we offer form−tool
sets for sale or hire. Use the GEBAA
1. Description body with threaded ports (G1") for line−
mounting applications.
Series WL22SDUR...−16 logic car-
tridges are 2/2, screw−in, actively con-

2. Symbol

WL22SDUR ...

3. Main characteristics

Designation 2/2 logic cartridge valve


Design direct acting conical−seat type
Mounting method screw−in cartridge M42 x 2
Size nominal size 16 mm, cavity type EB
to ISO 7789−42−06−0−07
Weight kg 1.10
Mounting attitude unrestricted
Flow direction 1 → 2 / 2 → 1, see symbol
Operating pressure range in 1, 2 and 3 bar ... 420
Opening pressure: standard 2.0
bar
as an option 0.4 / 6 / 10 / 13
Flow rate Qmax. l/min 350
Hydraulic fluid HL and HLP hydraulic oils to DIN 51 524;
for other fluids, please consult BUCHER
Fluid temperature range _C −25 ... +80
Ambient temperature _C −25 ... +80
Viscosity range mm 2/s 10 ... 650
(cSt) recommended 15 ... 250
Minimum fluid cleanliness level 20/18/15 to ISO 4406 : 1999

Replaces: W−11.20 1/5 Classification: 430.300.−.305.330.335


Reference: 400−P−160151−E−01/09.07
4. Performance graphs
measured with oil viscosity 33 mm2/s (cSt)

Δp−Q characteristics Δp−Q characteristics


in cavity type EB with annular groove in cavity type EB without annular groove
(1 → 2 and 2 → 1 with p3 = 0 bar) (1 → 2 and 2 → 1 with p3 = 0 bar)
32 40
36
28
32
24
28
20 24
16 20
→ Δp (bar)

→ Δp (bar)
16
12
12
8
8
4 4

25 50 75 100 150 200 250 300 350 25 50 75 100 150 200 250 300 350

→ Q (l/min) → Q (l/min)

The Δp characteristic is valid when the load pressure in the connection 1 → 2 / 2 → 1 is greater than the opening pressure.
If the load pressure is less than the opening pressure, the load pressure must first rise to overcome the opening pressure
before flow can occur.

5. Application examples
for passively controlled logic valves

Simplified symbol
A B

P T

Application with 4/3 directional valve Passive control


A B

3 3 3

2 bar ∅ 0.8 ∅ 0.8

2 2 2
1 1 1

3 3
2 bar ∅ 0.8 ∅ 0.8

2 2
1 1 P A

T B

P T

Passively controlled:
In the open condition (flow 1 → 2 / 2 → 1), there is a continuous consumption of pilot oil

400−P−160151−E−01/09.07 2/5
6. Dimensions / schematic section
5

46 A/F hex.
24

for fitting the cartridge


tightening torque
Ring
MA = 190 ... 210 Nm
19

M42 x 2 1
38,5
8,5

3
98,5

3
Area
Line−mounting body 4
74,5

A3
type GEBAA
2
22,5

ø 38
2 2
Cavity type EB Area
5 A2
3 Area
1 Model code
A1
1
46 A/F hex.

Seal kit no. DS−359, comprising:


It. Qty. Description Size
1 1 O−ring no. 129 ∅ 39.34 x 2.62 N90
2 1 O−ring no. 125 ∅ 32.99 x 2.62 N90
3 1 O−ring no. 124 ∅ 31.42 x 2.62 N90
4 2 Backup ring ∅ 32 x 2.0 x 1.4 FI0751
5 2 Backup ring ∅ 30 x 2.0 x 1.4 FI0751

7. Area− and pressure−relationships

Area A3 3

Area A2 2
Area A1
A3 : A1: A2 = 2 : 1 : 1
1

8. Installation and servicing


All work must be carried out with care seals are oiled or greased and use the changing seals, oil or grease the new
and by qualified personnel only. When specified tightening torque. When seals thoroughly before fitting them.
fitting the cartridge, ensure that the

400−P−160151−E−01/09.07 3/5
9. Ordering code

Ex. WL22 SD U R 2 2 D1 3 A − 16 _ − 1

WL22 = 2/2 logic valve


SD = seat valve with spool seal
U = soft switching
R = passive control, soft switching
1 = orifice ∅ 0.8
2 = orifice ∅ 0.5 (standard)
3 = orifice ∅ 0.6
4 = orifice ∅ 1.4
5 = orifice ∅ 1.3
spool orifice
6 = orifice ∅ 1.2
7 = orifice ∅ 1.1
8 = orifice ∅ 1.0
9 = orifice ∅ 0.9
0 = orifice ∅ 0.7
2 = area ratio (main spool : seat = 2 : 1)
D1 = orifice ∅ 0.8
D2 = orifice ∅ 0.6
D3 = orifice ∅ 1.5
D4 = orifice ∅ 1.4
D5 = orifice ∅ 1.3
orifice in port 3
D6 = orifice ∅ 1.2
D7 = orifice ∅ 1.1
D8 = orifice ∅ 1.0
D9 = orifice ∅ 0.9
D0 = orifice ∅ 0.7
1 = opening pressure 0.4 bar
3 = opening pressure 2.0 bar (standard)
5 = opening pressure 6.0 bar
6 = opening pressure 10 bar
7 = opening pressure 13 bar
A ... Q = standard model − see relevant data sheets
Z ... R = special features − please consult BUCHER
16 = nominal size 16 mm
(blank) = Nitrile seals (standard)
V = Viton seals
Special seals − consult Bucher
1 ... 9 = design number (omit when ordering new units)

10. Related data sheets


Old no. New no.
i−32 400−P−040011−E The form−tool hire programme
i−55.2 400−P−080111−E Cavity type EB to ISO 7789−42−06−0−07
W−11.10 400−P−160101−E 2/2 logic cartridge valve, series WL22SD...−16
W−11.15 400−P−160121−E 2/2 logic cartridge valve, series WL22SDL...−16
G−29.22 400−P−750115−E Line−mounting body, type GEBAA (G1")

400−P−160151−E−01/09.07 4/5
Notes

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 88 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 757 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without notice.

400−P−160151−E−01/09.07 5/5

Вам также может понравиться