Вы находитесь на странице: 1из 4

2/2 Solenoid Cartridge Valve, 10 mm

Two Stage Seat Valve Design, Flow is checked A ⇒ B


Series WRA22G ... / WRA22O ...

S 350 bar /140 l/min 10 mm. The straightforward design de-


S High flow rates livers an outstanding Price/Perform-
S ’No flow’ pilot stage ance ratio and good ∆p−Q characteris-
S All exposed steel parts are zinc tics. All exposed steel parts are zinc
plated to ISO 4042 plated to ISO 4042 and the valves are
S Wet−armature solenoids with high− therefore suitable for use in the
pressure core tube and slip−on coil harshest operating environments. The
S Coils can be changed without open- core tube / slip−on coil design allows
ing the hydraulic envelope coils to be changed without opening
S For BUCHER cavity types DD / DC the hydraulic envelope, even when the
S Line mounting body (G 1/2") is avail- valve is under pressure. Coils can be
able secured at any angle through 360° and
S Can be fitted in various stack−mount- are available with most common plug
ing bodies connectors. For customers who manu-
facture their own manifold blocks, we
1. Description offer form tools for sale or hire. For pipe−
mounting applications, the DC−12 and
Series WRA22...−10 directional valves DD−12 line mounting bodies (both G
are solenoid operated, two stage seat− 1/2" threads) are available.
type screw−in cartridges, nominal size
2. Symbols
WRA22GE...A−10 B WRA22OE...A−10 B
WRA22GN...A−10 WRA22ON...A−10

A A

3. Characteristics
Type 2/2 solenoid cartridge valve
Design two stage, seat type with flow checked from A ⇒ B
Mounting method screw−in cartridge
Size nom. 10 mm, BUCHER cavity type DD,
with adapter ring C: BUCHER cavity type DC
Mass kg 0,50
Mounting attitude unrestricted
Flow direction A ⇒ B / B ⇒ A, see symbols
Operating pressure bar to 350 in A and B
Flow rate Qmax l/min 140
Fluids Hydraulic oils HL and HLP to DIN 51 524,
other fluids − contact BUCHER
Fluid temperature range _C −25 ... + 80
Ambient temperature _C −25 ... + 50
Viscosity range cSt 10 ... 500, recommended 15 ... 250
Minimum fluid cleanless 18/14 to ISO 4406 /CETOP RP70H 8 ... 9 to NAS 1638
Standard voltages VAC 115, 230 50 ... 60 Hz
VDC 12, 24
Nom. voltage tolerance % $10
Nom. power consumption VAC 17W (Option: 25 W)
VDC 17W (Option: 27 W)
Duty cycle % 100
Enclosure protection IP 65 to DIN 40050
Electrical connection 3−pin square plug to DIN 43 650 / ISO 4400 (standard),
other connectors − contact BUCHER

Replaces: W−6.160 1/4 Classification: 430.30.15.15


Reference: 400−P−131120−E−/07.02
4. Performance graphs
Oil viscosity 33 cSt
coil steady−state temperature
10% under−voltage
∆p−Q characteristic ∆p−Q characteristic
WRA22GN..−A−10 A⇒B WRA22GE..−A−10
20 deenergised
20
18
A⇒B 18
16
B⇒A energised 16
14 B⇒A
deenergised 14
12 deenergised
12
10 B⇒A 10
B⇒A
→ ∆p (bar)

8 energised

→ ∆p (bar)
8
D

6 energised
6
4 4 A⇒B
2 2 energised
10 20 30 40 50 60 70 80 90 100 120 140 10 20 30 40 50 60 70 80 90 100 120 140
→ Q (l/min) → Q (l/min)

∆p−Q characteristic ∆p−Q characteristic


WRA22ON..−A−10 WRA22OE..−A−10
20 16
18 14
16 12
14 B⇒A
B⇒A 10
12 energised
energised 8
10 A⇒B
→ ∆p (bar)

B⇒A
→ ∆p (bar)

8 deenergised 6
de−
D

6 4 energised
4 B⇒A 2 A⇒B
2 deenergised deenergised

10 20 30 40 50 60 70 80 90 100 120 140 10 20 30 40 50 60 70 80 90 100 120 140


→ Q (l/min) → Q (l/min)

Performance limits
None within the
range
p = 350 (bar)
Q = 140 (l/min)

WRA22GN..A−10 WRA22GE..A−10 WRA22ON..A−10 WRA22OE..A−10


SWITCHING TIMES
Flow direction Solenoid ON 28 ... 180 ms 28 ... 108 ms 54 ... 142 ms 66 ... 132 ms
A ⇒ B and B ⇒ A Solenoid OFF 68 ... 102 ms 90 ... 292 ms 18 ... 60 ms 16 ... 66 ms
These times are strongly influenced by fluid pressure, flow rate and oil viscosity

400−P−131120−E−/07.02 2/4
5. Dimensions

Manual override ø 30

2,5
on type WR22O..10 only
Clearance to remove plug
12

10
PG 9

ø 36
58
53
81

Model
code
128,5
131

WRA22...
18

27 A/F hex. for fitting the cartridge


tightening torque
Ma = 23 ... 27 Nm

With adapter ring C:


25,5

BUCHER cavity type DC


M 24 x 1,5 For use, for example, in line mounting body type DC−12.
47,5

Without adapter ring C:


B BUCHER cavity type DD
13

For use, for example, in line mounting body type DD−12.

see related data sheets


A
ø 15,8 For flow checked B ⇒ A
ø 22,2 see data sheet ..131110..

6. Schematic section
4 Seat kit no. DS−276, comprising:
Itm. Qty. Description Size
1 1 Seal ∅ 22,1 / 16,5 x 2,5
2 1 O−ring no 117 ∅ 20,29 x 2,62 N90
3 1 O−ring no 020 ∅ 21,95 x 1,78 N90
4 2 O−ring ∅ 16,00 x 2,00 Viton
4 WRA22GE..A−10 5 1 O−ring ∅ 27,00 x 1,5 N75
WRA22GN..A−10

3
2 5
B B

1
A
A

4 WRA22OE..A−10
WRA22ON..A−10

3
2
B 5
B

1
A
A

400−P−131120−E−/07.02 3/4
7. Installation and servicing
All installation and servicing must be the new seals must be thoroughly oiled the specified tightening torque when fit-
carried out with care, and by qualified or greased before they are fitted. Use ting the cartridge.
personnel only. When changing seals,

8. Model code key

Ex. W R A 22G E D A − 10 _ − 1 24 VDC __


W = directional valve
R = check valve function, two−stage seat valve design
A = flow checked from A ⇒ B
22G = 2/2 function, deenergised closed
22O = 2/2 function, deenergised open
E = electrically operated, coil VAC = 17 W / VDC = 17 W (standard)
N = electrically operated, coil VAC = 25 W / VDC = 27 W
D = for BUCHER cavity type DD
C = for BUCHER cavity type DC (with adapter ring C)
A ... Q = standard model per relevant data sheet
Z ... R = special features by arrangement
10 = nominal size 10 mm
(blank) = Nitrile seals (standard)
V = Viton seals
Special seals by arrangement
1 ... 9 = design number (omit when ordering new units)
Voltage and current plainly specified
(blank) = with connector plug to DIN 43 650 / ISO 4400 (standard)
M100 = shipped without DIN connector plug
C = with socket to suit Kostal plug
J = with socket to suit Junior−Timer plug optional connector styles (plug not supplied)
F = with 500 mm flying leads

9. Related data sheets


Old no. New no.
i−32 400−P−040011−E The BUCHER Form Tool Hire Programme
i−45.1 400−P−060111−E BUCHER Cavity Type DC
i−45.2 400−P−060121−E BUCHER Cavity Type DD
W−2.141 400−P−120110−E Optional Electrical Connector Styles
G−24.20 400−P−740101−E Line− and Manifold Mounting Body DC−12 (G 1/2")
G−24.21 400−P−740111−E Line− and Manifold Mounting Body DD−12 (G 1/2")

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 88 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 757 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without notice.