Вы находитесь на странице: 1из 1

IMPROVED CLAP EM

N. SHARMA

SWITCH TESTED
T.K. Hareendran

+12V
RL1 N/O 0.5A
+ C4 D1
R1 VR1 R4 R5 C3
0.1µ 1N4148
10K 1K 10K 1M 1µF
25V N/C

4 8 14
R2
470W
3 7 R7
+ 2.2K
6 IC2 IC3 T1
IC1 2 LM555 3 3 1 BC548
CD4013
- 6 2
2 4
7 4
5
1 5 11 10 9 8 7 6
+
COND.
MIC

R3
1K +
- R6
C1 C2 1M
1µ 0.1µ
25V GND

IC1 = CA3140

Described here is an interesting circuit cated) connected through the relay that the flip-flop is wired in toggle mode
of a clap operated toggle switch, real- contacts is in off state. with data input (Pin5) connected to Q
ized using readily available inexpensive In the absence of a clap, the voltage at output (Pin 2). On receipt of this second
components. The whole circuit may be the input pin 3 of IC 1 is almost equal to clock pulse, the relay is switched off by
easily assembled on a medium size the positive rail voltage and hence the IC3.
veroboard. For powering the gadget, output of IC1(at pin 6) remains high. For compactness, one PCB mounting
an ac adaptor with an output of 12V dc Now output of the monostable IC 2 is in relay is used in the circuit. Part numbers
(500mA) is sufficient. For safe construc- low state. of this 12V DC-285W-Single contact
tion and easy trouble shooting, use of In case of a valid clap (sensitivity set by relay (from O/E/N) is 58-12-IC.
IC sockets are recommended. preset pot VR1), voltage at pin 3 of IC1 Operating current of this relay is only
Working of the circuit is simple, falls to make the output at pin6 low. around 42 mA and thus a low power
straight forword and self explanatory to Now IC2 gets triggered and IC3 is transistor BC548(T1) is enough for the
some extent. clocked by the monostable output. relay driver.
When power is applied to the circuit, Consequently IC3 output (pin 1) goes Finally, note that the CMOS IC (IC3)
the CMOS IC3(consists of two inde- high to forward bias the relay driver consists of two independent D-type
pendent flip-flops) is immediately re transistor T1 (via base bias resistor R7) Flip-Flops. Here only one is used for
setted by the power on reset (P.O.R) and the relay is energized. our circuit.
components C3 and R6. Now the relay At the time of a second clap, again IC3
is in idle state and the load (not indi- is clocked as mentioned earlier. Note