PREMIER Compact, PREMIER HE, SELECT Compact, SELECT Standard G e n e r a l S p e c i f i c a t i o n s 03

General Specifications

G E N E R A L S P E C I F I C AT I O N S
Approval and Certification The installation work must be carried out in accordance with
recognised good practice, and precautions taken to avoid
All M Y S O N Panel radiators are manufactured contamination which could lead to corrosion. If a corrosion
and tested to BS EN 442. Every radiator inhibitor or other water treatment is to be used, the
carries the BS Kitemark which certifies Manufacturer’s Instructions must be strictly followed.
independent approval of heat output and
The recommendations of BS 7593, Code of Practice for
BS EN 442 verifies production under a quality system
treatment of water in domestic hot water central heating
to BS EN ISO 9001.
systems, should be followed where appropriate.
All M Y S O N Panel radiators carry a ten year
guarantee from date of manufacture against Safety Precautions
defects caused by faulty materials or Radiators are hot when in use, and as such, present a risk of
manufacture. burns to users on prolonged contact. The temperature of a
radiator is dependent on the temperature of the system water,
Paint Finish as set by the system installer or user. Installers and users should
ensure that those who may come into close proximity to hot
Every M Y S O N Panel radiator is de-greased, phosphated and
radiators are aware of the risk of burns. Installers and users
primer coated.
should take all necessary steps to minimise the risks of burns.
An epoxy polyester finishing coat in white (RAL 9016) is applied If the risk is significant, consideration should be given to
to all front and rear surfaces allowing the radiator to be fitted installing low surface temperature radiators, or to placing guards
without further painting. in front of the radiators.

Packaging Heat Output


Every M Y S O N Panel radiator has plastic corner protection with Careful design of an optimum profile for the convector plate,
durable cardboard edge packaging as well as being fully and welding directly onto the wet and dry sections of the
wrapped in strong polythene. Each radiator is clearly labelled radiator, have combined to give high heat output per surface
with size and type, and packed with the appropriate number of area of radiator.
brackets.
The heat outputs shown in the table below are based on a mean
water to air temperature difference of 50 oC. When the
Fixings difference is not 50oC, the output should be multiplied by the
All M Y S O N Panel radiators are supplied with concealed wall appropriate factor from within the table:
mounting brackets. The table of dimensions gives further details.
For the correct installation of radiators it is essential that the
fixing of the radiator is carried out in such a way that it is suitable Centigrade Factor Fahrenheit
for intended use AND predictable misuse. A number of elements
need to be taken into consideration including the fixing method 40°C 0.75 72°F
used to secure the radiator to the wall, the type and condition of
45°C 0.87 81°F
the wall itself, and any additional potential forces or weights that
may happen to be applied to the radiator, prior to finalising 50°C 1.00 90°F
installation. 55°C 1.13 99°F
60°C 1.27 108°F
Accessories
65°C 1.41 117°F
Touch up Paint 70°C 1.55 126°F
A handy 12ml container of touch up paint with integral brush
applicator in RAL 9016 is available on request.
Example:
Air Vent Key
An alloy key for bleeding and venting is available on request. Heat emission required: 2000 Watts
Order Code: PREMRADKEY Room air temperature required: 20oC
Mean water temperature in radiator: 65 oC
Application
M Y S O N Panel radiators are for use on two pipe pumped 1. Temperature difference = 65-20 = 45 oC
indirect domestic and commercial central heating installations,
with a maximum working temperature of 100 oC. The system 2. From Factor Table 45oC gives a factor of: 0.87
should be designed in accordance with BS 5449 or BS 6880 as
3. Divide required heat emission
appropriate, with particular care taken to avoid air entry or water
by factor = 2000 = 2298 Watts
discharge.
0.87
We do not recommend the use of single feed indirect cylinders, 4. From selection tables choose any
as the possibility of aeration due to water interchange may lead radiator rated at 2298 Watts or more.
to corrosion.
22180 Panel Tech Guide:Layout 1 17/8/09 09:18 Page 6

PREMIER HE Te c h n i c a l I n f o r m a t i o n 05

Weight and Water Contents per Section


Height

300mm/12in 390mm/15in 530mm/21in 690mm/27in


Weight Water Content Weight Water Content Weight Water Content Weight Water Content
Type per Section per Section per Section per Section per Section per Section per Section per Section
(kg) (lb) (kg) (lb) (kg) (lb) (kg) (lb) (kg) (lb) (kg) (lb) (kg) (lb) (kg) (lb)
11 SC 0.37 0.82 0.14 0.31 0.49 1.07 0.16 0.35 0.69 1.52 0.20 0.45 0.90 1.99 0.25 0.54
21 DPX 0.84 1.84 0.32 0.70 1.18 2.59 0.41 0.90 1.54 3.38 0.49 1.08
22 DC 0.74 1.63 0.29 0.63 0.97 2.13 0.32 0.70 1.38 3.03 0.41 0.90 1.81 3.98 0.49 1.08

Mounting Positions, Dimensions and Wall Brackets (2 connections)*


79 (94) 111 135
3.1" (3.7") 4.4" 5.3" 15/21/27" Wall Bracket
SC DPX DC Bracket Plan View 12" Wall Bracket

T E C H N I C A L I N F O R M AT I O N
52
211
141
185
115
31 1.2" 71.5
31 1.2" 31 1.2" 37
31.5 71.5
45 (60) 100Min 70 100Min 83 100Min
31.5
1.8" (2.4") 3.9" 2.8" 3.9" 3.3" 3.9"
N.B. Long leg suitable for hanging Type 11 (SC) radiators
only. Short leg suitable for radiator Types 11, 21 & 22. *Available for full range
N.B. Figures in brackets apply when hanging with long leg.

Radiator Dimensions (4 connections)**


79 (94) 111 135
3.1" (3.7") 4.4" 5.3"

SC DPX DC

Nominal A
A A A Height (in) (mm) (in)

15 335 13.2
31 1.2" 31 1.2" 31 1.2" 21 475 18.7
N.B. Figures in brackets 45 (60) 100Min 70 100Min 83 100Min 27 635 25.0
apply when hanging with 1.8" (2.4") 3.9" 2.8" 3.9" 3.3" 3.9"
long leg.
**Available for selected sizes

Bracket Positions and Dimensions


143 143
Nominal B C
Height (in) (mm) (in) (mm) (in)

12 300 11.8 70 2.75


15 390 15.4 77 3.03
21 530 20.9 150 5.91
B
27 690 27.2 310 12.20
Nominal D
D
Length (in) (mm) (in)
C
77 864 34

N.B. Radiators up to and including 69" long have two brackets. Radiators 77" and longer
79 889 35
have three brackets. The position of the centre bracket is given in the above table. 85 965 38

Connections Operating Presssures


All MYSON PREMIER HE radiators are fitted with 2 - 1/2 inch BSP Every MYSON PREMIER HE radiator is tested to a pressure of 7 bar
connections. Selected sizes are available with 4 - 1/2 inch BSP connections, (101.5 psi) and is suitable for a working pressure of up to 5.4 bar (78 psi).
please refer to size guide pages 10-11.

Air Vents
An integral air vent is situated at the top right-hand corner of each panel.
22180 Panel Tech Guide:Layout 1 17/8/09 09:19 Page 11

10 PREMIER HE H e a t O u t p u t s

Heat Outputs

Nominal Length
Number of Sections
(mm - inches)
400 - 15 8
Nominal Height
800 - 31 16
300 mm / 12 in 1200 - 47 24
1600 - 63 32
2000 - 79 40

Nominal Length
Number of Sections
(mm - inches)
540 - 21 11
641 - 25 13
743 - 29 15
946 - 37 19
1047 - 41 21
Nominal Height
1149 - 45 23
390 mm / 15 in 1251 - 49 25
1352 - 53 27
1454 - 57 29
1556 - 61 31
1759 - 69 35
1962 - 77 39
2165 - 85 43

Nominal Length
Number of Sections
(mm - inches)
438 - 17 9
540 - 21 11
641 - 25 13
743 - 29 15
844 - 33 17
946 - 37 19
Nominal Height
1047 - 41 21
530 mm / 21 in 1149 - 45 23
1251 - 49 25
1352 - 53 27
1454 - 57 29
1556 - 61 31
1759 - 69 35
1962 - 77 39
2165 - 85 43

Nominal Length
Number of Sections
(mm - inches)
286 - 11 6
438 - 17 9
540 - 21 11
641 - 25 13
Nominal Height 743 - 29 15
690 mm / 27 in 844 - 33 17
946 - 37 19
1047 - 41 21
1149 - 45 23
1352 - 53 27
1556 - 61 31
1759 - 69 35
22180 Panel Tech Guide:Layout 1 17/8/09 09:19 Page 12

PREMIER HE H e a t O u t p u t s 11

Single Convector Double Panel “Xtra” Double Convector


Type 11 Type 21 Type 22

Output Output Output Output Output Output


Order Code Order Code Order Code
(watts) (Btu/h) (watts) (Btu/h) (watts) (Btu/h)
192 654 12 SC 15
393 1341 12 SC 31 764 2606 12 DC 31
594 2027 12 SC 47 1154 3939 12 DC 47
795 2714 12 SC 63 1546 5275 12 DC 63
1937 6607 12 DC 79

Output Output Output Output Output Output


Order Code Order Code Order Code
(watts) (Btu/h) (watts) (Btu/h) (watts) (Btu/h)
340 1160 15 SC 21 655 2234 15 DC 21
404 1379 15 SC 25 778 2654 15 DC 25
468 1597 15 SC 29 709 2418 15 DPX 29 901 3075 15 DC 29*
596 2034 15 SC 37* 903 3080 15 DPX 37* 1148 3916 15 DC 37*
660 2252 15 SC 41* 1000 3410 15 DPX 41* 1271 4336 15 DC 41*
724 2471 15 SC 45* 1096 3741 15 DPX 45* 1394 4757 15 DC 45*
788 2689 15 SC 49* 1193 4072 15 DPX 49* 1517 5177 15 DC 49*
852 2907 15 SC 53* 1290 4403 15 DPX 53* 1641 5598 15 DC 53*
916 3126 15 SC 57 1387 4733 15 DPX 57* 1764 6018 15 DC 57
980 3344 15 SC 61 1484 5064 15 DPX 61 1887 6439 15 DC 61
1108 3781 15 SC 69 1678 5725 15 DPX 69 2134 7280 15 DC 69
1236 4218 15 SC 77 1872 6387 15 DPX 77 2380 8121 15 DC 77
2627 8962 15 DC 85

Output Output Output Output Output Output


Order Code Order Code Order Code
(watts) (Btu/h) (watts) (Btu/h) (watts) (Btu/h)
365 1244 21 SC 17* 539 1839 21 DPX 17* 688 2347 21 DC 17*
449 1532 21 SC 21* 664 2265 21 DPX 21* 847 2891 21 DC 21*
534 1821 21 SC 25* 789 2692 21 DPX 25* 1007 3436 21 DC 25*
618 2109 21 SC 29* 914 3118 21 DPX 29* 1166 3980 21 DC 29*
703 2397 21 SC 33* 1039 3544 21 DPX 33* 1326 4524 21 DC 33*
787 2686 21 SC 37* 1164 3971 21 DPX 37* 1485 5068 21 DC 37*
872 2974 21 SC 41* 1289 4397 21 DPX 41* 1645 5613 21 DC 41*
H E AT O U T P U T S

956 3263 21 SC 45* 1414 4824 21 DPX 45* 1804 6157 21 DC 45*
1041 3551 21 SC 49* 1539 5250 21 DPX 49* 1964 6701 21 DC 49*
1125 3840 21 SC 53* 1664 5676 21 DPX 53* 2124 7245 21 DC 53*
1210 4128 21 SC 57* 1789 6103 21 DPX 57 2283 7790 21 DC 57
1294 4416 21 SC 61* 1914 6529 21 DPX 61 2443 8334 21 DC 61
1463 4993 21 SC 69* 2164 7382 21 DPX 69 2762 9422 21 DC 69
1633 5570 21 SC 77 2413 8235 21 DPX 77 3081 10511 21 DC 77
1802 6147 21 SC 85 3400 11599 21 DC 85

Output Output Output Output Output Output


Order Code Order Code Order Code
(watts) (Btu/h) (watts) (Btu/h) (watts) (Btu/h)
301 1026 27 SC 11* 553 1886 27 DC 11*
461 1573 27 SC 17* 671 2290 27 DPX 17* 847 2891 27 DC 17*
568 1937 27 SC 21* 827 2821 27 DPX 21* 1044 3562 27 DC 21*
675 2302 27 SC 25* 983 3352 27 DPX 25* 1240 4232 27 DC 25*
782 2667 27 SC 29* 1138 3884 27 DPX 29* 1437 4903 27 DC 29*
888 3031 27 SC 33* 1294 4415 27 DPX 33* 1633 5573 27 DC 33*
995 3396 27 SC 37* 1450 4946 27 DPX 37* 1830 6243 27 DC 37*
1102 3761 27 SC 41* 1605 5477 27 DPX 41 2026 6914 27 DC 41*
1209 4126 27 SC 45* 1761 6008 27 DPX 45 2223 7584 27 DC 45*
1423 4855 27 SC 53 2072 7070 27 DPX 53 2616 8925 27 DC 53
1637 5584 27 SC 61 2383 8132 27 DPX 61 3009 10266 27 DC 61
1850 6314 27 SC 69 3402 11607 27 DC 69
N.B. The tabulated heat outputs are quoted at a mean water to air temperature difference of 50 oC. *Available as 4 tap option.