Вы находитесь на странице: 1из 1

12MMØ HOR.

0.30

10mm Ø TIES SP. AT


6 - 16mm.Ø HOR. BARS, TIED w/ 10mm.Ø SP. 3-50 , 5-100 REST AT
@ 0.05,3 @ 0.10, 3 @ 0.15 REST @ 0.20 m.O.C. 200m
A. REINFORCED CONCRETE
1. THE QUALITY AND DESIGN OF ALL REINFORCED CONCRETE CONSTRUCTION
SHALL CONFORM WITH THE BUILDING CODE REQUIREMENTS FOR REINFORCED 0.35 GB GB
CONCRETE (ACI=318.83) AND MANUAL OF STANDARD PRACTICE FOR
DETAILING REINFORCED CONCRETE STRUCTURES (ACI=315.80); SCHEDULE OF REINFORCED CONCRETE BEAM :
2. ALL CONCRETE SHALL BE MACHINE MIXED AND MECHANICAL VIBRATOR SHALL 0.50 m
BE USED FOR COMPACTING CONCRETE; WEB
BACKFILL BACKFILL BEAM DIMENSIONS
AT SUPPORT AT MID - SPAN REINFORCEMENT
3. MINIMUM CLEAR CONCRETE COVERING FOR REINFORCING STEEL SHALL BE: MARK ( mm. ) ( 10 mm. Ø )
BEAMS AND COLUMNS = 40 mm, FORMED SURFACE BELOW GRADE FOR
16 mmØ BARS AND SMALLER = 50 mm FOR BARS LARGER THAN 16 mmØ NAT. GROUND LINE NAT. GROUND LINE
5 - 16mm.Ø 3 - 16mm.Ø 1 - SET 10mm.Ø TIES
= 75 mm, CONCRETE POURED AGAINST EARTH = 75 mm;
FTB 200 x 350 SP.@ 3 - 0.05 , 3 - 0.10,
4. ALL REINFORCING STEEL ANCHOR BOLTS, DOWELS AND OTHER INSERTS 3 - 16mm.Ø
3 - 0.15 REST @ 0.20 m.
5 - 16mm.Ø
SHALL BE WELL SECURED IN POSITION BEFORE PLACING CONCRETE;
5. NO CONCRETING SHALL BE ALLOWED UNLESS ALL BAR PLACEMENTS HAVE VERIFY
BEEN INSPECTED BY THE STRUCTURAL ENGINEER;
5 - 16mm.Ø 3- 16mm.Ø 1 - SET 10mm.Ø TIES
B. STRUCTURAL STEEL GB SP.@ 3 - 0.05 , 3 - 0.10,
200 x 350
1. ALL STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE REQUIREMENTS 0.35 FTB FTB 3 - 16mm.Ø 5- 16mm.Ø
3 - 0.15 REST @ 0.20 m.
OF ASTM A36, CERTIFIED MILL TESTS SHALL BE SUBMITTED BY THE
CONTRACTOR TO THE STRUCTURAL ENGINEER; 0.30
2. THE STEEL FABRICATOR SHALL SUBMIT SHOP DETAILS AND ERECTION
DRAWINGS FOR APPROVAL BY THE STRUCTURAL ENGINEER. THE DRAWINGS GRAVEL BED 2- 16mm.Ø 2- 16mm.Ø 1 - SET 10mm.Ø TIES
SHALL SHOW CONNECTION DETAIL AND METHOD OF ERECTION TO BE RB 250 x 400 2 - 12mm.Ø 2 - 12mm.Ø SP.@ 3 - 0.05 , 3 - 0.10,
EMPLOYED, NO MATERIALS SHALL BE ORDERED NOR FABRICATION STARTED 9 - 16mm.Ø BASE BARS 1.25 2 - 16mm.Ø 2 - 16mm.Ø 3 - 0.15 REST @ 0.20 m.
SP. @ 0.200 m. O.C. , B.W. "W"
UNTIL SUCH DRAWINGS ARE APPROVED BY THE STRUCTURAL ENGINEER;
0.30
3. ALL DIMENSIONS IN THE PLANS SHALL BE VERIFIED BY THE STEEL 6 - 16mm.Ø VERT. BARS
FABRICATOR IN THE FIELD IN COORDINATION WITH THE GENERAL CONTRACTOR
4. ALL BOLTS SHALL BE IN STRICT CONFORMITY TO THE REQUIREMENTS OF
ASTM A-307;
5. ALL WELDING ELECTRODES SHALL CONFORM TO THE REQUIREMENTS OF
ASTM A-233;

"L"
1.25 0.30
C. REINFORCEMENT STEEL
1. REINFORCEMENTS SHALL BE DEFORMED BARS CONFORMING TO ASTM - 322;
TO ASTM-615 (DEFORMATION);
2. MINIMUM LAP OF SPLICES UNLESS OTHERWISE SHOWN
a) FOR CONCRETE = 50 BAR DIAMETERS NOT LESS THAN 500 mm
PLAN
b) FOR MASONRY = 40 BAR DIAMETERS

D. FOUNDATION
3 F-C DETAIL
Ø
1. ALL FOOTINGS SHALL REST ON NATURAL GROUND.
S-1 SCALE 1 : 30 MTS.

FFL
E. MISCELLANEOUS
1. ALL DISCREPANCY BETWEEN ARCHITECTURAL AND STRUCTURAL PLANS SHALL
BE REPORTED IMMEDIATELY TO THE ARCHITECT BEFORE PROCEEDING WITH EARTH FILL
Ø
THE PORTION OF THE WORK INVOLVED.

(MIN)
600
FOOTING SCHEDULE REINF. CONC. COLUMN Ø
Ø

200
FOOTING REBARS COLUMN MARK C-1 Ø
FOOTING
MARK REMARKS
L W T BAR R1 BAR R2 TOP OF 300 mm
ROOF BEAM
MM. MM. MM. 300
TO 300 mm Ø
F1 1250 1250 300 8 - 16Ø 8 - 16Ø ISOLATED FOOTING TOP OF
FOUNDATION
PLAN WF SECTION
VERTICAL BARS 6 - 16 mmØ

4 WALL & FOOTING DETAILS


2 - SET 10 mmØ TIES
LATERAL TIES 4 @ 50, 3 @ 100,2 @ 150
REST @ 200 mm., O.C.

S-1 SCALE: 1:20

STRUCTURAL/CIVIL ENGINEER : APPROVED BY: REVISION: PROJECT TITLE: PROJECT OWNER: R.A. 9266
SECTION 20 SHEET CONTENTS:

S-1
DRAWINGS AND SPECIFICATIONS DULY SIGNED, STAMPED
ONE STOREY MS. JULIET B. DURAN
OR SEALED AS INSTRUMENTS OF SERVICE ARE THE PROPERTIES
UNLAWFUL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT
OF THE ARCHITECT OR AUTHOR OF SAID DOCUMENTS FOR THE
RESIDENTIAL BUILDING USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR
BUILDING, WEATHER EXECUTED PARTLY OR IN WHOLE.
P.R.C. REG NO.: P.T.R. NO.:
MUNICIPAL ENGINEER C.P.C. HOME ADDRESS
PRESIDENTIAL DEGREE NO. 49 OR PROTECTION OF AS SHOWN
6 11
NARRA SITIO CANNIOGAN, INTELLECTUAL PROPERTY DATED NOVEMBER 14, 1972.
VALIDITY: DATE ISSUED: LOCATION: DATE ISSUED: SAN MANUEL, PANGASINAN WORKS OF ART, ARCHITECTURE, MODELS AND DESIGNS
ARE CREATIVE AND CONSIDERED AS PART OF THE
DATE APPROVED INTELLECTUAL PROPERTY OF THE AUTHOR DULY PROTECTED
UNDER P.D. 49.
TIN NO.: PLACE ISSUED: PLACE ISSUED: JANUARY 16, 2021
NARRA SITIO CANNIOGAN, SAN MANUEL, PANGASINAN