TIME DELAY RELAYS

600 Series, Snap-Action Automatic or Manual Reset

Key Features The 600 series is available in a variety of


capacity ratings which are identified below:
The Klixon® 600 series (A.R. = Automatic Reset, M.R. = Manual
• Silent Operation
• Voltage Compensating Reset).
thermal time delay is a • Snap-Action
snap-acting relay that • Small Size Switch Rating
60000 - High Capacity - A.R.
performs in any position • Low Cost
60002 - Millivolt Capacity - A.R.
without contact chatter *60004 - Extra High Capacity - A.R.
• Contact ratings - to 30 Amps at 240 Volts
and 23 Amps at 277 Volts
60006 - Pilot Duty Capacity - A.R.
or noise. A wide variety • Automatic or Manual Reset
60011 - High Capacity - M.R.
of switch configurations • Shock and Vibration Resistant
Manual Overide
are available including 60012 - MIllivolt Capacity - M.R.
• Mounts in any Position
• DPST, SPST, or SPDT Switch Action Manual Overide
SPST, SPDT, and DPST 60013 - Extra High Capacity - M.R.
Trip Free
automatic reset and Description 60015 - High Capacity - M.R.
SPST manual reset. The positive temperature coefficient (PTC)
Manual Overide
heater element provides voltage compensa- The switch action is identified by the fol-
The switch and tion over a wide range without the danger lowing letter designations.
actuating elements of over-heating at high voltage. This (N.O. = Normally Open;
assures device actuation under low voltage N.C. = Normally Closed)
incorporate the proven conditions due to its unique feature of
Klixon® snap-action always stabilizing at a specified temperature
Switch Action

regardless of ambient temperature or A – SPST N.O.


bimetallic disc. voltage. This will allow the use of a com- B – SPST N.C.
Sensata Technologies mon device over a wide voltage range C – SPDT contacts 1-3 N.O.
(example 208V to 277V). Available heater D – SPDT contacts 1-3 N.C.
has been a leading voltages range from 6 volts to 277 volts. E – DPST N.O.
global supplier of This switch and actuating element has F – DPST N.C.
sensors & switches proven to be highly reliable since its J – DPST N.C., M.R.
introduction in 1960. A variety of termi-
for over 50 years. nals and mounting plates are available to
* U.L. Recognition Pending

meet the installation requirements of


most applications.

Klixon is a registered trademark of Sensata Technologies ©Copyright Sensata Technologies 2008


TIME DELAY RELAYS
600 Series, Snap-Action Automatic or Manual Reset

Electrical Clearances Mountings Timings


The switch circuit of the 600 series is Standard mounting plates shown below The 600 series relay can be supplied in a
designed to provide electrical clearances of are available to meet most application wide variety of timings to meet specific
3/8 inch through air to ground and 1/2 requirements. application requirements. Timings are
inch over surface to ground except on varied by the selection of the proper
switch constructions E, F and J where
Terminals operating temperature of the bimetallic
Standard terminal types are listed disc and the proper heater configuration
clearances are 1/4 inch through air and below. Special switch terminals such as
3/8 inch over surface to ground. The elec- for the specific application.
double quick connects, female quick
trical clearances of the heater circuit vary connects, and .187” x .032” quick connects Examples of standard timing char-
depending upon the specific construction may be available for a specific switch ter- acterisitcs at 75oF are shown below.*
required in an application. The clearance to minal. Consult marketing for details.
ground of the heater circuit is designed by Voltage Heat Time* Cool Time**
one of the following numbers. Switch terminals:
solder type
1-60 sec. 1-45 sec.

screw type
1-30 45-75
24

.250” x .032” Q.C.


Designation Through Over 30-75 1-40
Number Air Surface 30-110 1-45
0† 3/8 inch 1/2 inch Heater Terminals 20-70 sec. 20-80 sec.
1 1/16 inch 1/16 inch 120/240
solder type 30-110 15-65
4 1/4 inch 3/8 inch
.187” x .020” Q.C. *Cool time after 6 min. soak time
† Class II (30(volts or less)) heaters .250” x .032” Q.C. (available at **Optional timings available at extra cost –
please consult marketing
additional cost)
Use 12 gauge or larger wire for
Heater-Switch Connections
The 600 type can be supplied with one
Ambient Rating
loads greater than 15 amperes. Ambient Exposure Range:
heater terminal common to either terminal
–40oF to 250oF
#1 or #3 of the switch assembly. Standard
Ambient Operating Range:
construction is with separate heater
–40oF to 152oF
terminals. (200oF Rating Available)
1.615 (REF.)
(41.02) Mounting Plates
1.187 ±.010 (*Metric Dimensions in parenthesis)
(30.15 ±.25)

2.125 (REF.)
2.000 (REF.) (53.98)
(50.80)
.203
1.640 ±.010
(41.66 ±.25) (5.16)

2.000 (REF.) (50.80)


4.875
55254-1 (REF.) 1.640 ±.010
(50.80) (41.66 ±.25)
1.615 (REF.)
4.500 ±.010
(41.02)
(114.38 ±.25)
1.187 ±.010
3.200
(30.15 ±.25) (REF.)
(81.28)
2.000 (REF.)
(50.80) 2.775 ±.010
(70.49 ±.25)
1.640 ±.010
(41.66 ±.25)

.203 DIA. (5.16)


55254-2 55254-4 55254-5
TIME DELAY RELAYS
600 Series, Snap-Action Automatic or Manual Reset

Part Number System


Model

600 00 A 1 C XXX

Heater Common Physical and operating


Switch Switch
Type Electrical Heater-Switch characteristics for a
Rating Action
Clearance Terminal specific device.

U.L. Electrical Ratings**


U.L. File E9977 CSA File 21794
U.L. Guide XAPX2 CSA Guide 400-E-O; CSA Class 4813, 4823

Device 120 V 240 V 277 V 480 V


Pilot Pilot Pilot Pilot
Switch Duty Duty Duty Duty Millivolt
Model Action Contacts Res FLA LRA VA Res FLA LRA VA Res FLA LRA VA Res FLA LRA VA DC
*60000 A,B,C,D, 1-3 30 23 88 480 30 23 88 480 23 23 88 1630 12.5 5 10 400
C,D 1-2 10 5.8 34.8 125 5 4.2 17.4 270 5 – – 125 3 3 5 125
E,F 1-3 30 23 88 480 30 23 88 480 23 23 88 1630 12.5 – – –
E,F 4-5 30 23 88 480 30 23 88 480 23 23 88 163 12.5 5 10 400
J 1-3 / 4-5 30 23 88 480 30 23 88 480
60002 A,B 1-3 125
60006 A,B,C,D 1-3 125
C,D 1-2 125
60011 B 1-3 30 10 60 480 30 7 42 480 690 48 690
60012 B 1-3 800
60013 B 1-3 48 16 96 480 48 8 48 690 48
60015 B 1-3 30 10 60 480 30 7 42 480 25 690
60016 B 1-3 125
*In addition to the ratings in the table, the 60000 A, B, E and F are U.L. rated for a combination load of 23 amps resistive at 240 VAC in series with a blower motor load up to 7 FLA / 42 LRA at
240 VAC. Consult marketing for additional ratings. The 60000 A, B, E, F are also U.L. rated for a combination load of 13 amps resistive and 5 amps inductive / 30 LRA at 480 VAC.
**Use 12 gauge or larger wire size for loads greater than 15 amperes.

How to Order Samples


When ordering samples, faster service can be 6. Ambient: 9. Heater terminals:
rendered if the application is described in detail. Operating: Solder
Please specify the following: Min. oF Max. oF .187 x .020 Q.C.
Exposure: .250 x .032 Q.C.
1. Type relay oF Max. oF
Min. 10. Switch Terminal:
2. No. of samples
7. Switch Action: #1 type Angle
3. Heat time: sec. to sec. #2 type Angle
oF A - SPST N.O. E - DPST N.O.
@ volts@ B - SPST N.C. F - DPST N.C. #3 type Angle
4. Cool time: sec. to sec. after C - SPDT contacts 1-3 N.O. J - DPST N.C.-M.R. #4 type Angle
min. soak time @ oF D - SPDT contacts 1-3 N.C. 11. Mounting Plate
5. Heater voltage: 8. Heater Construction: 12. Circuit Diagram
12 208/240 Separate terminals 13. Electrical load:
24 277 14. Equipment used on:
Heater common to: 15. Function of relay
120 #1 or #3 16. Annual volume
TIME DELAY RELAYS
600 Series, Snap-Action Automatic or Manual Reset

Metric dimensions in parenthesis Double Pole Single Throw


Single Pole Single Throw Single Pole Double Throw Manual reset – Manual Overide

1.276 ±0.008
1.276 ±0.008 1.276 ±0.008
(32.41 ±.20)
(32.41 ±.20) (32.41 ±.20)

1.125 MAX.
1.125 MAX. 0.781 ±0.008 1.125 MAX. 0.781 ±0.008 (28.58) 0.781 ±0.008
(28.58) (19.84 ±.20) (28.58) (19.84 ±.20) (19.84 ±.20)

2.468 MAX.
2.360 MAX. (62.69)
2.125 MAX.
(59.94)
(53.98)

4 5
1.650 MAX. 3 1 2
(41.91) 1.343 MAX. 1.890 MAX. (48.00) 2.125 MAX.
3 1 1 3
(34.11) (53.98)

3 1 2
C 1
H 4 5
3
H H 1 3
H H
Single Pole Single Throw
Double Pole Single Throw Manual Reset – Trip free Applications
1.276 ±0.008 1.276 ±0.008
Sequencing of heater banks in:
• Electric furnaces
(32.41 ±.20) (32.41 ±.20)

1.125 MAX. 0.781 ±0.008 1.125 MAX.


• Baseboard heaters
• Duct heaters
(28.58) (28.58) 0.781 ±0.008
(19.84 ±.20) (19.84 ±.20)

• Suspension heaters
• Recreational vehicle blower and
element control.
2.360 MAX.
2.468 MAX. (59.94)

• Heat pump blower and heating


(62.69)

element control.
• Motor speed switching in air condition-
4 5
1.950 MAX. 1.953 MAX. 3 1

ing (high speed)/ heating systems (low


(49.53) (49.61)
1 3

15o speed) where a single set of contacts


handle combination motor and heater
element loading in the heater function.
4 5 • Control circuits requiring definite
1 3 sequence of operation on both start up
and shut down.
1 3
H H
H H

Sensata Technologies Important Notice: Sensata Technologies (Sensata) reserves the right to
make changes to or discontinue any product or service identified in this
529 Pleasant Street, MS B19 publication without notice. Sensata advises its customers to obtain the latest
Attleboro, Massachusetts 02703-0964 version of the relevant information to verify, before placing any orders, that
the information being relied upon is current. Sensata assumes no responsi-
Phone: 1-888-438-2214 bility for infringement of patents or rights of others based on Sensata
1-508-236-1894 applications assistance or product specifications since Sensata does not
possess full access concerning the use or application of customers’ products.
1-508-236-3192 Sensata also assumes no responsibility for customers’ product designs.
Fax: (508) 236-2349