Вы находитесь на странице: 1из 71

OptiX RTN 600 Radio Transmission System

V100R002

IDU 605 Hardware Description

Issue 01
Date 2008-06-20
Part Number 00428560

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any
assistance, please contact our local office or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Copyright © Huawei Technologies Co., Ltd. 2008. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but the statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description Contents

Contents

About This Document.....................................................................................................................1


1 Introduction to the Product......................................................................................................1-1
1.1 Network Application.......................................................................................................................................1-2
1.2 Equipment Type..............................................................................................................................................1-3

2 Chassis..........................................................................................................................................2-1
2.1 Chassis Structure.............................................................................................................................................2-2
2.2 Installation Mode.............................................................................................................................................2-2
2.3 IDU Labels......................................................................................................................................................2-2

3 IDU 605.........................................................................................................................................3-1
3.1 Functions and Features....................................................................................................................................3-2
3.2 System Architecture........................................................................................................................................3-3
3.3 Logic Board Configuration.............................................................................................................................3-4
3.4 Signal Processing Flow...................................................................................................................................3-6
3.5 Front Panel......................................................................................................................................................3-8
3.5.1 Front Panel Diagram..............................................................................................................................3-8
3.5.2 Switches.................................................................................................................................................3-9
3.5.3 Indicators..............................................................................................................................................3-10
3.5.4 Interfaces..............................................................................................................................................3-12
3.6 Technical Specifications...............................................................................................................................3-18

4 Accessories...................................................................................................................................4-1
4.1 E1 Panel...........................................................................................................................................................4-2
4.2 PDU.................................................................................................................................................................4-4
4.2.1 Front Panel.............................................................................................................................................4-4
4.2.2 Functions and Working Principle...........................................................................................................4-5
4.2.3 Power Distribution Mode.......................................................................................................................4-6

5 Cables...........................................................................................................................................5-1
5.1 Power Cable....................................................................................................................................................5-2
5.2 Protection Ground Cable.................................................................................................................................5-2
5.2.1 Protection Ground Cable of the IDU 605...............................................................................................5-2
5.2.2 E1 Protection Ground Cable of an E1 Panel..........................................................................................5-3
5.3 IF Jumper.........................................................................................................................................................5-4

Issue 01 (2008-06-20) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
Contents IDU 605 Hardware Description

5.4 E1 Cable..........................................................................................................................................................5-4
5.4.1 From the PO1/PH1 Board to the External Equipment...........................................................................5-4
5.4.2 From the PO1/PH1 Board to the E1 Panel.............................................................................................5-7
5.5 Orderwire Line................................................................................................................................................5-8
5.6 Network Cable.................................................................................................................................................5-9

A Indicators and Power Consumption for Quick Reference...............................................A-1


B Glossary......................................................................................................................................B-1
C Acronyms and Abbreviations................................................................................................C-1

ii Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description Figures

Figures

Figure 1-1 Radio transmission network composed of the OptiX RTN 600.........................................................1-2
Figure 1-2 Hybrid transmission network composed of the OptiX RTN 600 and OptiX series optical transmission
products.................................................................................................................................................................1-3
Figure 1-3 IDU 605 1A........................................................................................................................................1-4
Figure 1-4 IDU 605 1B........................................................................................................................................1-4
Figure 1-5 IDU 605 2B........................................................................................................................................1-4
Figure 2-1 Chassis structure of the IDU 605........................................................................................................2-2
Figure 2-2 Positions of the IDU 605 labels..........................................................................................................2-4
Figure 3-1 System architecture of the IDU 605...................................................................................................3-4
Figure 3-2 IDU 605 logic board configuration....................................................................................................3-5
Figure 3-3 Signal processing flow........................................................................................................................3-6
Figure 3-4 Front panel of the IDU 605 1A...........................................................................................................3-9
Figure 3-5 Front panel of the IDU 605 1B...........................................................................................................3-9
Figure 3-6 Front panel of the IDU 605 2B...........................................................................................................3-9
Figure 3-7 Power interface.................................................................................................................................3-12
Figure 3-8 RJ-45 connector................................................................................................................................3-13
Figure 3-9 Wrong connection of the ETH and the ETH-HUB interfaces..........................................................3-14
Figure 3-10 DB44 connector..............................................................................................................................3-16
Figure 4-1 Front panel of an E1 panel..................................................................................................................4-2
Figure 4-2 Pin assignments of an E1 port (E1 panel)...........................................................................................4-2
Figure 4-3 PDU front panel..................................................................................................................................4-4
Figure 4-4 Block diagram of the PDU working principle....................................................................................4-6
Figure 4-5 Internal structure of the PDU in the DC-C mode...............................................................................4-7
Figure 4-6 Internal structure of the PDU in the DC-I mode.................................................................................4-7
Figure 5-1 Diagram of the power cable................................................................................................................5-2
Figure 5-2 Diagram of the protection ground cable of the IDU 605....................................................................5-3
Figure 5-3 Diagram of the protection ground cable of an E1 panel.....................................................................5-3
Figure 5-4 View of the IF jumper........................................................................................................................5-4
Figure 5-5 Diagram of the 75-ohm cable.............................................................................................................5-5
Figure 5-6 Diagram of the 120-ohm cable...........................................................................................................5-5
Figure 5-7 Diagram of the E1 cable that connects a PO1/PH1 board to an E1 panel..........................................5-7
Figure 5-8 Diagram of the orderwire wire...........................................................................................................5-9
Figure 5-9 Diagram of the network cable...........................................................................................................5-10

Issue 01 (2008-06-20) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description Tables

Tables

Table 1-1 Types of IDU 605.................................................................................................................................1-3


Table 2-1 Description of the IDU labels..............................................................................................................2-3
Table 3-1 Functional units of the IDU 605...........................................................................................................3-4
Table 3-2 List of IDU 605 logic boards...............................................................................................................3-5
Table 3-3 Transmit direction................................................................................................................................3-6
Table 3-4 Receive direction..................................................................................................................................3-7
Table 3-5 Description of the switches..................................................................................................................3-9
Table 3-6 Description of the indicators of the IDU 605 1A/1B.........................................................................3-10
Table 3-7 Description of the indicators of the IDU 605 2B...............................................................................3-11
Table 3-8 Pin assignments of the Power interface.............................................................................................3-12
Table 3-9 Description of the management and auxiliary interfaces...................................................................3-12
Table 3-10 Pin assignments of the ETH/ETH-HUB interface...........................................................................3-13
Table 3-11 ETH/ETH-HUB indicator description.............................................................................................3-13
Table 3-12 Pin assignments of the ALARM interface.......................................................................................3-14
Table 3-13 Pin assignments of the COM interface.............................................................................................3-15
Table 3-14 Pin assignments of the F1 interface.................................................................................................3-15
Table 3-15 Pin assignments of the S1 interface.................................................................................................3-15
Table 3-16 Description of the E1 interface of the IDU 605 1A.........................................................................3-16
Table 3-17 Description of the E1 interface of the IDU 605 1B/2B....................................................................3-16
Table 3-18 Pin assignments of the DB44 connector..........................................................................................3-16
Table 3-19 Description of the ODU (IF) interface of the IDU 605 1A/1B........................................................3-17
Table 3-20 Description of the ODU (IF) interface of the IDU 605 2B..............................................................3-18
Table 3-21 IF performance.................................................................................................................................3-18
Table 3-22 Baseband signal processing performance of the modem.................................................................3-18
Table 3-23 E1 interface performance.................................................................................................................3-19
Table 3-24 Synchronous data interface performance.........................................................................................3-19
Table 3-25 Asynchronous data interface performance.......................................................................................3-19
Table 3-26 Orderwire interface performance.....................................................................................................3-20
Table 3-27 Integrated system performance of the IDU 605...............................................................................3-20
Table 4-1 Interface description of an E1 panel.....................................................................................................4-2
Table 4-2 Pin assignments of an E1 port (E1 panel)............................................................................................4-3
Table 4-3 PDU interface description....................................................................................................................4-5
Table 5-1 Connection Table of the power cable...................................................................................................5-2

Issue 01 (2008-06-20) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
Tables IDU 605 Hardware Description

Table 5-2 75-ohm E1 cable connections..............................................................................................................5-5


Table 5-3 120-ohm E1 cable connections............................................................................................................ 5-6
Table 5-4 Connection table of the E1 cable that connects a PO1/PH1 board to an E1 panel.............................. 5-8
Table 5-5 Orderwire wire connections.................................................................................................................5-9
Table 5-6 Pin assignments of the MDI.................................................................................................................5-9
Table 5-7 Pin assignments of the MDI-X...........................................................................................................5-10
Table 5-8 Cable connection of the straight through cable..................................................................................5-10
Table 5-9 Cable connection of the crossover cable............................................................................................5-11
Table A-1 Description of the indicators of the IDU 605 1A/1B.........................................................................A-1
Table A-2 Description of the indicators of the IDU 605 2B...............................................................................A-2
Table A-3 Power consumption of the IDU 605...................................................................................................A-3

vi Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description About This Document

About This Document

Purpose
The OptiX RTN 600 system consists of the indoor unit (IDU) and outdoor unit (ODU). The IDU
accesses services, and performs the multiplexing/demultiplexing and IF processing on the
services. The ODU is an outdoor unit of the OptiX RTN 600 system. It performs frequency
conversion and amplification for signals. The IDU 605 is a type of IDU supported by the OptiX
RTN 600 system. This document describes the chassis, hardware, accessories, and cables of the
IDU 605. This document helps readers to gain comprehensive understanding of the hardware of
the IDU 605.

Related Versions
The following table lists the product versions related to this document.

Product Name Version

OptiX RTN 600 V100R002

OptiX iManager T2000 V200R006C03

Intended Audience
This document is intended for the OptiX RTN 600 relevant personnel. Before reading this
document, you need to be familiar with the following:

l Basics of digital microwave communication


l Basics of the OptiX RTN 600

Organization
This document is organized as follows.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
About This Document IDU 605 Hardware Description

Chapter Content

1 Introduction to the Introduces the OptiX RTN 600 and each type of IDU 605.
Product

2 Chassis Describes the structure, installation holes, and installation


modes of the IDU 605 chassis.

3 IDU 605 Describes the functions, working principle, interfaces, and


technical specifications of the IDU 605.

4 Accessories Describes the accessories of the IDU 605.

5 Cables Describes the functions, appearance, and connections of


various cables of the IDU 605.

A Indicators and Power Provides descriptions of all the indicators and the power
Consumption for Quick consumption of each type of IDU 605 for quick reference.
Reference

Glossary Lists the terms used in this document.

C Acronyms and Lists the acronyms and abbreviations used in this document.
Abbreviations

Conventions
Symbol Conventions
The symbols that may be found in this document are defined as follows.

Symbol Description

Indicates a hazard with a high level of risk, which if not


avoided, will result in death or serious injury.

Indicates a hazard with a medium or low level of risk, which


if not avoided, could result in minor or moderate injury.

Indicates a potentially hazardous situation, which if not


avoided, could result in equipment damage, data loss,
performance degradation, or unexpected results.

Indicates a tip that may help you solve a problem or save time.

Provides additional information to emphasize or supplement


important points of the main text.

2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description About This Document

General Conventions
The general conventions that may be found in this document are defined as follows.

Convention Description

Times New Roman Normal paragraphs are in Times New Roman.

Boldface Names of files, directories, folders, and users are in


boldface. For example, log in as user root.

Italic Book titles are in italics.


Courier New Examples of information displayed on the screen are in
Courier New.

Update History
Updates between document issues are cumulative. Therefore, the latest document issue contains
all updates made to previous issues.

Updates in Issue 01 (2008-06-20)


Initial release.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 1 Introduction to the Product

1 Introduction to the Product

About This Chapter

This chapter provides basic information on the OptiX RTN 600 and its IDU 605 in terms of
product application and equipment type.
1.1 Network Application
The OptiX RTN 600 radio transmission system is a split-mount digital microwave transmission
system developed by Huawei Technologies Co., Ltd. (hereinafter referred to as Huawei).
1.2 Equipment Type
The IDU 605 is available in several types and can meet the requirements of different scenarios.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 1-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
1 Introduction to the Product IDU 605 Hardware Description

1.1 Network Application


The OptiX RTN 600 radio transmission system is a split-mount digital microwave transmission
system developed by Huawei Technologies Co., Ltd. (hereinafter referred to as Huawei).
The OptiX RTN 600 provides various service interfaces and features flexible configuration and
easy installation. The OptiX RTN 600 can construct a radio transmission network that serves as
backhaul links for mobile communication networks or private networks. The OptiX RTN 600
can also construct a hybrid network that is used to transmit SDH, PDH, and Ethernet services
together with the OptiX series optical transmission products of Huawei.

Figure 1-1 Radio transmission network composed of the OptiX RTN 600

RTN 600
1+0 (IDU 620)
RTN 600 1+1
(IDU 605)

1+1 E1 1+1 1+0

RTN 600 RTN 600 RTN 600 RTN 600 RTN 600
(IDU 605) (IDU 605) (IDU 620) (IDU 620) (IDU 620)
1+0 1+0
1+0

1+0

RTN 600
(IDU 610) RTN 600 RTN 600
(IDU 610) (IDU 620)

PDH microwave link SDH microwave link

NOTE

The OptiX RTN 600 configures different types of indoor units (IDU), including IDU 610, IDU 620, and IDU
605, to meet the requirements of different application scenarios, and the OptiX RTN 600 outdoor units (ODU)
can be applied in all the application scenarios.

1-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 1 Introduction to the Product

Figure 1-2 Hybrid transmission network composed of the OptiX RTN 600 and OptiX series
optical transmission products

SDH/PDH/
Ethernet

STM-4 ring

STM-1 ring

SDH/PDH/
Ethernet

OptiX optical
OptiX RTN 600
transmission product

1.2 Equipment Type


The IDU 605 is available in several types and can meet the requirements of different scenarios.
Table 1-1 lists the differences among the three types of IDU 605.

Table 1-1 Types of IDU 605


Type of IDU 605 RF Configuration Number of E1s Power

1A 1+0 5xE1 –48 V/–60 V

1B 1+0 16xE1 –48 V/–60 V

2B 1+1 HSB/FD/SD 16xE1 –48 V/–60 V

In terms of appearance, the difference among the types of IDU 605 lies in the interfaces on the
front panel. Figure 1-3 to Figure 1-5 show the appearance of the IDU 605 1A/1B/2B.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 1-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
1 Introduction to the Product IDU 605 Hardware Description

Figure 1-3 IDU 605 1A

Figure 1-4 IDU 605 1B

Figure 1-5 IDU 605 2B

1-4 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 2 Chassis

2 Chassis

About This Chapter

The IDU 605 applies the integrated design and does not house pluggable boards. The chassis
has an integrated structure.

2.1 Chassis Structure


The dimensions of the IDU 605 are as follows: 442 mm x 220 mm x 44 mm (width x depth x
height). The IDU 605 has an integrated structure and supports air convection.
2.2 Installation Mode
The IDU 605 chassis supports multiple installation modes.
2.3 IDU Labels
Labels, such as the product nameplate label, certificate of qualification label, grounding label,
and operation warning label are on the chassis of the IDU 605. You should know the meanings
of the labels and perform operations according to the indications of the labels to prevent personal
injury and damage to the equipment.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 2-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
2 Chassis IDU 605 Hardware Description

2.1 Chassis Structure


The dimensions of the IDU 605 are as follows: 442 mm x 220 mm x 44 mm (width x depth x
height). The IDU 605 has an integrated structure and supports air convection.
Figure 2-1 shows the chassis structure of the IDU 605.

Figure 2-1 Chassis structure of the IDU 605

2.2 Installation Mode


The IDU 605 chassis supports multiple installation modes.
The IDU 605 can be installed as follows:
l In a 300 mm ETSI cabinet
l In a 600mm ETSI cabinet
l In a 450 mm 19-inch cabinet
l In a 600 mm 19-inch cabinet
l In an open rack
l On the wall
l On a table

2.3 IDU Labels


Labels, such as the product nameplate label, certificate of qualification label, grounding label,
and operation warning label are on the chassis of the IDU 605. You should know the meanings
of the labels and perform operations according to the indications of the labels to prevent personal
injury and damage to the equipment.

Label Description
Table 2-1 provides the description of the labels on the IDU chassis.

2-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 2 Chassis

Table 2-1 Description of the IDU labels


Label Label Name Indication

Product The product name and certification


OptiX RTN 605
电源额定值 POWER RATING: -48 - -60V ; 4A nameplate label
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.

N14036

华为技术有限公司 中国制作
HUAWEI TECHNOLOGIES CO.,LTD. MADE IN CHINA

合格证/QUALIFICATION CARD
Certificate of The equipment is qualified.
qualification
label

HUAWEI
华为技术有限公司 中国制作
HUAWEI TECHNOLOGIES CO.,LTD. MADE IN CHINA

High The temperature of the top panel of


temperature the IDU 605 may exceed 70℃ when
warning label the ambient temperature is higher
than 55℃. In this case, you need to
wear protective gloves before
touching the equipment.

ESD protection The equipment is sensitive to static


label electricity. Take antistatic measures
ESD when you perform operations. The
ESD protection label also indicates
the grounding jack of the ESD wrist
strap.

Grounding label The grounding position

Power interface Read the operation instructions


! warning label before you connect a power cable.

! WARNING
Operation The ODU power switch must be
-48V OUTPUT warning label turned off before the IF cable is
TURN OFF POWER BEFORE removed.
DISCONNECTING IF CABLE

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 2-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
2 Chassis IDU 605 Hardware Description

Label Position
Figure 2-2 shows the positions of the labels on the chassis of the IDU 605.

Figure 2-2 Positions of the IDU 605 labels


合格证/QUALIFICATION CARD
OptiX RTN 605
电源额定值 POWER RATING: -48 - -60V ; 4A

This device complies with Part 15 of the FCC Rules.


Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.

N14036

HUAWEI
华为技术有限公司 中国制作 华为技术有限公司 中国制作
HUAWEI TECHNOLOGIES CO.,LTD. MADE IN CHINA HUAWEI TECHNOLOGIES CO.,LTD. MADE IN CHINA

! WARNING

! -48V OUTPUT
TURN OFF POWER BEFORE
DISCONNECTING IF CABLE
ESD

2-4 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

3 IDU 605

About This Chapter

The IDU 605 is the PDH IDU of the OptiX RTN 600 and is used at an end node on a radio
transmission network. This chapter describes the functions, features, system architecture,
configuration of the logical boards, signal processing flow, front panel, and technical
specifications of the IDU 605.

3.1 Functions and Features


The IDU 605 processes PDH microwave services and provides common management channels
and auxiliary channels.
3.2 System Architecture
The IDU 605 consists of a series of functional units, including the service interface unit, IF unit,
control unit, auxiliary interface unit, and power unit.
3.3 Logic Board Configuration
An IDU 605 is composed of one system board and one power board. Each functional unit on
the physical boards of the IDU 605 corresponds to a logical board and is allocated with a logical
slot. In this way, the NMS can manage the functional units as independent objects.
3.4 Signal Processing Flow
This section describes the signal processing flow of the OptiX RTN 600 that uses the IDU 605
through the example of E1 signals.
3.5 Front Panel
There are cable interfaces, a power switch, an ODU switch, and indicators on the front panel of
the IDU 605.
3.6 Technical Specifications
The technical specifications of the IDU 605 include the following: IF performance, baseband
signal processing performance of the modem, E1 port performance, synchronous data interface
performance, asynchronous data interface performance, orderwire interface performance, board
mechanical behavior, and power consumption.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

3.1 Functions and Features


The IDU 605 processes PDH microwave services and provides common management channels
and auxiliary channels.

IF Processing
l Multiplexes E1 service signals into microwave frame signals.
l Codes and decodes PDH microwave frame signals.
l Modulates and demodulates PDH microwave frame signals.
l Modulates and demodulates ODU control signals.
l Combines and splits service signals, ODU control signals, and –48 V power supplies.
l Supports the automatic transmit power control (ATPC) function.

Service Processing
l The IDU 605 1A can access 5xE1 signals.
l The IDU 605 1B/2B can access 16xE1 signals.
l The IDU 605 supports the setting of the impedance of E1 signals through the software (75-
ohm or 120-ohm).

Protection Processing
l The IDU 605 1A/1B/2B supports 1+1 protection for the input power.
l The IDU 605 2B also supports the following:
– 1+1 HSB/FD/SD protection
– 1+1 FD/SD hitless switching
NOTE

l For the details of 1+1 HSB, 1+1 FD and 1+1 SD, refer to the OptiX RTN 600 Radio Transmission System
Feature Description.

System Control and Communication Function


l Provides the system control and communication function to manage the IDU and ODU.
l Provides the function of collecting performance events and alarm information.
l Provides the function of communicating with the NMS.

Overhead Processing
l Processes the overheads of PDH microwave frame signals.
l Supports the setting and querying of the link ID.

Power Processing
l Supports two inputs of the –48 V/–60 V power.
l Outputs –48 V power and +3.3 V power to supply power to other boards.

3-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

l Detects and protects the input power.

Management and Auxiliary Interfaces


l Provides one NM interface and one NE cascade interface.
l Provides one management serial port.
l Provides one 3-input and 1-output alarm interface.
l Provides one RS-232 asynchronous data interface.
l Provides one 64 kbit/s G.703-compliant synchronous data interface.
l Provides one orderwire interface for addressing calls and orderwire group calls.
l Supports the setting of the synchronous data interface as a transparent transmission
interface for orderwire bytes to realize the orderwire spanning function.

Maintenance Features
l Supports inloop and outloop at the IF port.
l Supports inloop and outloop at the E1 tributary.
l Supports the PRBS 15 test at an E1 port.
l Supports the detecting of the temperature.
l Supports the resetting of the main control unit.
l Supports the querying of the manufacturing information of the board.
l Supports the remote loading of the software and data of an NE on the NMS.
l Supports the in-service upgrade of the FPGA.
NOTE

l For the details of the loopback function, refer to the OptiX RTN 600 Radio Transmission System Maintenance
Guide.
l When the main control unit is reset, the running NE software and the software module of the logic boards
in the CPU are reset, but the services are not affected.

3.2 System Architecture


The IDU 605 consists of a series of functional units, including the service interface unit, IF unit,
control unit, auxiliary interface unit, and power unit.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Figure 3-1 System architecture of the IDU 605

RF signal
ODU

IDU 605 IF signal Antenna


Service Overhead Orderwire data
Service signal signal Auxiliary External alarm
E1 interface IF unit interface data
unit unit Synchronous/
asynchronous
Control bus
data

Control Power
unit unit

NM data -48V/-60V DC

Table 3-1 Functional units of the IDU 605


Functional Unit Function Description

Service interface unit l Accesses E1 signals.

IF unit l Converts signals between baseband service signals and IF analog


signals.
l Provides the operations and maintenance (O&M) channel
between the IDU and the ODU.
l Supports FEC.
l Processes overheads.

Control unit l System communications and control.


l System configuration and management.
l Collects alarms and monitors performance.

Auxiliary interface l Provides the orderwire interface.


unit l Provides the synchronous/asynchronous data interface.
l Provides the external alarm input/output interface.

Power unit l Accesses –48 V/–60 V DC power.


l Provides +3.3 V power for the IDU.
l Provides –48 V power for the ODU.

3.3 Logic Board Configuration


An IDU 605 is composed of one system board and one power board. Each functional unit on
the physical boards of the IDU 605 corresponds to a logical board and is allocated with a logical
slot. In this way, the NMS can manage the functional units as independent objects.

3-4 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Figure 3-2 IDU 605 logic board configuration

IDU 605 1A

PW SCC EOW PF1 IF0


Slot 1 Slot 2 Slot 3 Slot 4 Slot 8

IDU 605 1B

PW SCC EOW PH1 IF0


Slot 1 Slot 2 Slot 3 Slot 4 Slot 8

IDU 605 2B

PW SCC EOW PH1 IF0 IF0


Slot 1 Slot 2 Slot 3 Slot 4 Slot 7 Slot 8

NOTE

The PW board indicates PW48B board.

Table 3-2 List of IDU 605 logic boards


Logical Full Name Logical Slot Description
Board
Name

PW48B –48 V power board Slot 1 Provides two –48 V DC power


signals. The power distribution
mode is DC-C.

SCC System control and Slot 2 Provides the NMS interface.


communication board

EOW Orderwire board Slot 3 Provides the synchronous/


asynchronous data interface and
orderwire phone interface.

PF1 5xE1 tributary board Slot 4 Provides five 75-ohm/120-ohm


E1 interfaces. The interface
impedance can be set by using the
software.

PH1 16xE1 tributary board Provides 16 75-ohm/120-ohm E1


interfaces. The interface
impedance can be set by using the
software.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-5


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Logical Full Name Logical Slot Description


Board
Name

IF0 PDH IF board Slot 8 (IDU Provides one IF interface. The


605 1A/1B) logical slot number of the ODU
Slot 7/8 (IDU that is connected to the IF0 board
605 2B) is 10 plus the slot number of the
IF0 board.
Supports the E1-based
microwave frame structure.

NOTE

The PW48B is the logical board that corresponds to the physical board with the same name. The PF1/PH1, IF0,
SCC, and EOW are the logical boards mapped by the system board. Different types of IDU 605 have different
system boards and thus have different logical boards.

3.4 Signal Processing Flow


This section describes the signal processing flow of the OptiX RTN 600 that uses the IDU 605
through the example of E1 signals.

Figure 3-3 Signal processing flow


IDU 605

Service IF RF
E1 PF1/ signal signal signal
IF0 ODU
PH1

Antenna

Table 3-3 Transmit direction


No. Logical Board Signal Processing Description

1 PF1/PH1 (IDU) l Accesses E1 signals.


l HDB3 decoding.
l Transmits the 2.048 Mbit/s signals to the IF0 board.

3-6 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

No. Logical Board Signal Processing Description

2 IF0 (IDU) l Forms microwave frames by adding microwave frame


overheads to the 2.048 Mbit/s signals.
l Scrambling.
l FEC coding.
l Digital modulation.
l D/A conversion.
l Analog modulation.
l Combines the analog IF signals and ODU O&M signals.
The ODU O&M signals have been modulated by the
auxiliary modem.
l Transmits the combined signals and –48 V power to the
ODU through the coaxial cable.

3 ODU l Splits the analog IF signals, ODU O&M signals, and –48
V power.
l Converts the analog IF signals into RF signals through up
conversions and amplifications.
l Transmits the RF signals to the antenna through the
waveguide.

Table 3-4 Receive direction


No. Logical Board Signal Processing Description

1 ODU l Isolates and filters RF signals.


l Converts the RF signals into analog IF signals through
down conversions and amplifications.
l Controls the level of the signals through the automatic gain
control (AGC) circuit.
l Combines the IF signals and the ODU O&M signals. The
O&M signals have been modulated by an auxiliary
modem.
l Transmits the combined signals to the IF0 board.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-7


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

No. Logical Board Signal Processing Description

2 IF0 (IDU) l Splits the received analog IF signals and ODU O&M
signals.
l Controls the level of the analog IF signals through the AGC
circuit.
l Performs A/D conversion for the IF signals.
l Digital demodulation.
l Time domain adaptive equalization.
l FEC decoding.
l Synchronizes and descrambles the frames.
l Extracts overheads from microwave frames.
l Extracts the 2.048 Mbit/s signals from the microwave
frames and transmits the 2.048 Mbit/s signals to the PF1/
PH1.

3 PF1/PH1 (IDU) l HDB3 coding.


l Outputs E1 signals.

3.5 Front Panel


There are cable interfaces, a power switch, an ODU switch, and indicators on the front panel of
the IDU 605.
3.5.1 Front Panel Diagram
The IDU 605 is available in three types: IDU 605 1A, IDU 605 1B, and IDU 605 2B. Thus, there
are three front panels.
3.5.2 Switches
There is a POWER switch on the front panel of the IDU 605 1A/1B. There is a POWER switch,
an ODU1 switch, and an ODU2 switch on the front panel of the IDU 605 2B.
3.5.3 Indicators
The IDU 605 1A/1B has the following indicators: PWR, IDU, and ODU. The IDU 605 2B has
the following indicators: PWR, IDU, ACT1, ACT2, ODU1, and ODU2.
3.5.4 Interfaces
There are the following interfaces on the front panel of the IDU 605: power interfaces,
management and auxiliary interfaces, E1 interfaces, and ODU (IF) interfaces.

3.5.1 Front Panel Diagram


The IDU 605 is available in three types: IDU 605 1A, IDU 605 1B, and IDU 605 2B. Thus, there
are three front panels.

3-8 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Figure 3-4 Front panel of the IDU 605 1A


ON
ETH-HUB ALARM F1

48V 60V PWR


ODU
RTN1(+) RTN2(+)

ODU
ODU IDU E1
OFF 1~5 WARNING
-48V OUTPUT
POWER TURN OFF POWER BEFORE
DISCONNECTING IF CABLE
ESD NEG1(-) NEG2(-) ETH COM S1 PHONE

1 2 3 4 5 6 7 8

1. ESD jack 2. Power interfaces 2. Main power switch 4. Indicators


5. Management and auxiliary interfaces 6. E1 interface 7. ODU (IF) interface 8. Grounding terminal

Figure 3-5 Front panel of the IDU 605 1B


ON
ETH-HUB ALARM F1
E1
48V 60V PWR
9~16
ODU
RTN1(+) RTN2(+)

ODU

IDU E1
OFF 1~8 WARNING
-48V OUTPUT
POWER TURN OFF POWER BEFORE
DISCONNECTING IF CABLE
ESD NEG1(-) NEG2(-) ETH COM S1 PHONE

1 2 3 4 5 6 7 8

1. ESD jack 2. Power interfaces 2. Main power switch 4. Indicators


5. Management and auxiliary interfaces 6. E1 interfaces 7. ODU (IF) interface 8. Grounding terminal

Figure 3-6 Front panel of the IDU 605 2B


ON
ODU1 ETH-HUB ALARM F1
E1
48V 60V PWR
ON OFF 9~16
ODU1 ODU2
RTN1(+) RTN2(+) ACT2 ACT1
PULL ODU2 ODU1
ODU2 IDU E1
OFF 1~8 WARNING
-48V OUTPUT
POWER ON OFF TURN OFF POWER BEFORE
DISCONNECTING IF CABLE
ESD NEG1(-) NEG2(-) ETH COM S1 PHONE

1 2 3 4 5 6 7 8 9

1. ESD jack 2. Power interfaces 3. Main power switch


4. ODU power switches 5. Indicators 6. Management and auxiliary interfaces
7. E1 interfaces 8. ODU (IF) interfaces 9. Grounding terminal

3.5.2 Switches
There is a POWER switch on the front panel of the IDU 605 1A/1B. There is a POWER switch,
an ODU1 switch, and an ODU2 switch on the front panel of the IDU 605 2B.

Table 3-5 Description of the switches

Switch Description Remarks


Name

POWER Main power switch When you press the OFF side, the circuit is open.
When you press the ON side, the circuit is closed.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-9


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Switch Description Remarks


Name

ODU1 Power switch of ODU 1 The switch is equipped with a lockup device. To
move the switch, you need to first pull out the switch
ODU2 Power switch of ODU 2 lever partially. When the switch is set to "O", it
indicates that the circuit is open. When the switch is
set to "I", it indicates that the circuit is closed.

3.5.3 Indicators
The IDU 605 1A/1B has the following indicators: PWR, IDU, and ODU. The IDU 605 2B has
the following indicators: PWR, IDU, ACT1, ACT2, ODU1, and ODU2.

Table 3-6 Description of the indicators of the IDU 605 1A/1B


Indicat Status Meaning
or

PWR On (green) The power supply is working normally.

On (red) The +3.3 V power supply or the –48 V power


supply is faulty.

Off There is no power access.

IDU On (green) The IDU works normally.

On (red) A critical or major alarm occurs in the


services.

On (yellow) A minor or warning alarm occurs in the


services.

On for 100 ms and off for 100 ms When the board is being powered on or being
alternately (green) reset, the software is being loaded.

On for 500 ms and off for 500 ms The board is in the BIOS holdover state. The
alternately (green) NE software does not exist or is not running.

ODU On (green) The ODU works normally.

On (red) A critical or major alarm occurs in the ODU,


or the ODU has no power access.

On (yellow) A minor or warning alarm occurs in the ODU.

3-10 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Table 3-7 Description of the indicators of the IDU 605 2B


Indicat Status Meaning
or

PWR On (green) The power supply is working normally.

On (red) The +3.3 V power supply or the –48 V power


supply is faulty.

Off There is no power access.

IDU On (green) The IDU works normally.

On (red) A critical or major alarm occurs in the


services.

On (yellow) A minor or warning alarm occurs in the


services.

On for 100 ms and off for 100 ms When the board is being powered on or being
alternately (green) reset, the software is being loaded.

On for 500 ms and off for 500 ms The board is in the BIOS holdover state. The
alternately (green) NE software does not exist or is not running.

ACT1 On (green) IF 1+1 protection is in the switching state


(that is, works in the standby system).

Off IF 1+1 protection is in the normal state (that


is, works in the active system).

ACT2 On (green) IF 1+1 protection is in the normal state (that


is, works in the active system).

Off IF 1+1 protection is in the switching state


(that is, works in the standby system).

ODU1 On (green) The standby ODU works normally.

On (red) The standby ODU is faulty or has no power


access.

On (yellow) A minor or warning alarm occurs in the


standby ODU.

ODU2 On (green) The active ODU works normally.

On (red) The active ODU is faulty or has no power


access.

On (yellow) A minor or warning alarm occurs in the active


ODU.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-11


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

3.5.4 Interfaces
There are the following interfaces on the front panel of the IDU 605: power interfaces,
management and auxiliary interfaces, E1 interfaces, and ODU (IF) interfaces.

Power Interfaces
For the pin assignments of the power interface, see Figure 3-7 and refer to Table 3-8.

Figure 3-7 Power interface


48V 60V
RTN1(+) RTN2(+)
3 4

4 3

2 1

1 NEG1(-) NEG2(-) 2

Table 3-8 Pin assignments of the Power interface


Interface Pin Signal

Power interface 1 Input power (negative, –48 V/–60 V)

3 Input power (positive, power ground)

Management and Auxiliary Interfaces


The management and auxiliary interfaces of the IDU 605 are as follows: NM Ethernet interface,
NE cascade interface, external alarm interface, management serial port, synchronous data
interface, asynchronous data interface, and orderwire interface.

Table 3-9 Description of the management and auxiliary interfaces


Interface Description Type of Connector

ETH NM Ethernet interface RJ-45

ETH-HUB NE cascade interface

ALARM External alarm interface

COM Management serial port

F1 Synchronous data interface

S1 Asynchronous data interface

3-12 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Interface Description Type of Connector

PHONE Orderwire interface RJ-11

The NM interfaces, synchronous data interface, asynchronous data interface, management serial
port, and external alarm interface use RJ-45 connectors.

Figure 3-8 RJ-45 connector

87654321

For the pin assignments of the ETH and ETH-HUB interfaces, see Figure 3-8 and refer to Table
3-10.

Table 3-10 Pin assignments of the ETH/ETH-HUB interface

Interface Pin Signal

ETH/ETH-HUB 1 Transmitting data (+)

2 Transmitting data (–)

3 Receiving data (+)

6 Receiving data (–)

4, 5, 7, 8 Reserved

NOTE
The ETH/ETH-HUB interface supports MDI/MDI-X auto-sensing, which means it can also transmit data
through pins 3 and 6, and receive data through pins 1 and 3.

The ETH/ETH-HUB interface has two indicators. For the description of the two indicators, refer
to Table 3-10.

Table 3-11 ETH/ETH-HUB indicator description

Indicator Status Meaning

LINK (green) On The link is normal.

Off The link fails.

ACT (yellow) On or flashing The port is transmitting or receiving


data.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-13


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Indicator Status Meaning

Off The port is not transmitting or receiving


data.

CAUTION
The ETH and the ETH-HUB are like two ports of a hub. When the two ports are used in
networking, they cannot be connected to each other through Ethernet links. Otherwise, an
Ethernet loop is formed which can result in a network storm and repeated NE resetting. Figure
3-9 shows two wrong connection modes.

Figure 3-9 Wrong connection of the ETH and the ETH-HUB interfaces

ETH-HUB ETH-HUB
LAN

ETH ETH

For the pin assignments of the ALARM interface, see Figure 3-8 and refer to Table 3-12.

Table 3-12 Pin assignments of the ALARM interface

Interface Pin Signal

ALARM 1 The 1st input alarm signal

2 Ground of the 1st input alarm signal

3 The 2nd input alarm signal

4 Ground of the 2nd input alarm signal

5 The 3rd input alarm signal

6 Ground of the 3rd input alarm signal

7 The 1st output alarm signal (+)

8 The 1st output alarm signal (–)

For the pin assignments of the COM interface, see Figure 3-8 and refer to Table 3-13.

3-14 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Table 3-13 Pin assignments of the COM interface


Interface Pin Signal

COM 3 Transmitting data

4 Ground

5 Ground

6 Receiving data

1, 2, 7, 8 Reserved

For the pin assignments of the F1 interface, see Figure 3-8 and refer to Table 3-14.

Table 3-14 Pin assignments of the F1 interface


Interface Pin Signal

F1 1 Receiving data (+)

2 Receiving data (–)

3 Transmitting data (+)

6 Transmitting data (–)

4, 5, 7, 8 Reserved

For the pin assignments of the S1 interface, see Figure 3-8 and refer to Table 3-15.

Table 3-15 Pin assignments of the S1 interface


Interface Pin Signal

S1 3 Transmitting data

4 Ground

5 Ground

6 Receiving data

1, 2, 7, 8 Reserved

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-15


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

E1 Interfaces

Table 3-16 Description of the E1 interface of the IDU 605 1A

Interface Description Type of Connector

1–5 E1 ports 1–5 DB44

Table 3-17 Description of the E1 interface of the IDU 605 1B/2B

Interface Description Type of Connector

1–8 E1 ports 1–8 DB44

9–16 E1 ports 9–16 DB44

For the pin assignments of the DB44 connector of the IDU 605, see Figure 3-10 and refer to
Table 3-18.

Figure 3-10 DB44 connector


Pos. 1

Pos. 44

Table 3-18 Pin assignments of the DB44 connector

Pin Signal Pin Signal

15 1st E1 transmitting differential 38 1st E1 receiving differential


signal (+) signal (+)

30 1st E1 transmitting differential 23 1st E1 receiving differential


signal (-) signal (–)

14 2nd E1 transmitting differential 37 2nd E1 receiving differential


signal (+) signal (+)

29 2nd E1 transmitting differential 22 2nd E1 receiving differential


signal (-) signal (–)

13 3rd E1 transmitting differential 36 3rd E1 receiving differential


signal (+) signal (+)

3-16 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Pin Signal Pin Signal

28 3rd E1 transmitting differential 21 3rd E1 receiving differential


signal (-) signal (–)

12 4th E1 transmitting differential 35 4th E1 receiving differential


signal (+) signal (+)

27 4th E1 transmitting differential 20 4th E1 receiving differential


signal (-) signal (–)

11 5th E1 transmitting differential 34 5th E1 receiving differential


signal (+) signal (+)

26 5th E1 transmitting differential 19 5th E1 receiving differential


signal (-) signal (–)

10 6th E1 transmitting differential 33 6th E1 receiving differential


signal (+) signal (+)

25 6th E1 transmitting differential 18 6th E1 receiving differential


signal (-) signal (–)

9 7th E1 transmitting differential 32 7th E1 receiving differential


signal (+) signal (+)

24 7th E1 transmitting differential 17 7th E1 receiving differential


signal (-) signal (–)

8 8th E1 transmitting differential 31 8th E1 receiving differential


signal (+) signal (+)

7 8th E1 transmitting differential 16 8th E1 receiving differential


signal (-) signal (–)

Others Reserved - -

NOTE

In the case of the DB44 connector of the IDU 605 1A, only the 1st E1 to 5th E1 described in Table 3-18
are valid.

ODU (IF) Interfaces

Table 3-19 Description of the ODU (IF) interface of the IDU 605 1A/1B
Interface Description Type of Connector

ODU IF port of the ODU TNC

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-17


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Table 3-20 Description of the ODU (IF) interface of the IDU 605 2B
Interface Description Type of Connector

ODU1 IF port of the standby ODU TNC

ODU2 IF port of the active ODU

3.6 Technical Specifications


The technical specifications of the IDU 605 include the following: IF performance, baseband
signal processing performance of the modem, E1 port performance, synchronous data interface
performance, asynchronous data interface performance, orderwire interface performance, board
mechanical behavior, and power consumption.

IF Performance

Table 3-21 IF performance


Item Performance

IF signal

Transmit frequency of the IF 350


board (MHz)

Receive frequency of the IF 140


board (MHz)

Impedance (ohm) 50

ODU O&M signal

Modulation scheme ASK

Transmit frequency of the IF 5.5


board (MHz)

Receive frequency of the IF 10


board (MHz)

Baseband Signal Processing Performance of the Modem

Table 3-22 Baseband signal processing performance of the modem


Item Performance

Encoding mode RS encoding

3-18 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 3 IDU 605

Item Performance

Adaptive time- The equalizer consists of the 12-tap feed forward equalizer filter and
domain equalizer for the 3-tap decision feedback equalizer.
baseband signals

E1 Interface Performance
The performance of the E1 interface is compliant with ITU-T G.703. The following table
provides the primary performance.

Table 3-23 E1 interface performance


Item Performance

Nominal bit rate (kbit/s) 2048

Code pattern HDB3

Wire pair in each One coaxial wire pair One symmetrical wire pair
transmission direction

Impedance (ohm) 75 120

Synchronous Data Interface Performance

Table 3-24 Synchronous data interface performance


Item Performance

Transmission path Uses the user-defined byte in the overhead of the microwave
frame.

Nominal bit rate (kbit/s) 64

Interface type Codirectional

Interface characteristics Meets the ITU-T G.703 standard.

Asynchronous Data Interface

Table 3-25 Asynchronous data interface performance


Item Performance

Transmission path Uses the user-defined byte in the overhead of the microwave
frame.

Nominal bit rate (kbit/s) ≤ 19.2

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 3-19


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
3 IDU 605 IDU 605 Hardware Description

Item Performance

Interface characteristics Meets the RS-232 standard.

Orderwire Interface Performance

Table 3-26 Orderwire interface performance


Item Performance

Transmission path Uses the user-defined byte in the overhead of the microwave
frame.

Orderwire type Addressing call

Wire pair in each One symmetrical wire pair


transmission direction

Impedance (ohm) 600

NOTE

The IDU 605 also supports the orderwire group call function. For example, when an IDU 605 calls the number
of 888, the orderwire group call number, all the IDU 605 orderwire phones in the orderwire subnet ring until a
phone is answered. Then, a point-to-point orderwire phone call is established.

Mechanical Behavior and Power Consumption

Table 3-27 Integrated system performance of the IDU 605


Item Performance

IDU 605 1A IDU 605 1B IDU 605 2B

Dimensions 442 mm x 220 mm x 44 mm (width x depth x height)

Weight < 2.5 kg

Power < 17 W < 18 W < 31 W


consumption

3-20 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 4 Accessories

4 Accessories

About This Chapter

The accessories of the OptiX RTN 600 IDU 610/620 include the E1 panel and the power
distribution unit (PDU). You can select the accessories depending on the requirements.

4.1 E1 Panel
When an IDU is installed in a 19-inch cabinet, you can install an E1 panel in the cabinet. The
E1 panel can function as the DDF of the IDU.
4.2 PDU
The PDU is installed on the top of a 19-inch cabinet. The PDU is used to distribute the input
power to the equipment in the cabinet.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 4-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
4 Accessories IDU 605 Hardware Description

4.1 E1 Panel
When an IDU is installed in a 19-inch cabinet, you can install an E1 panel in the cabinet. The
E1 panel can function as the DDF of the IDU.
The dimensions of the E1 panel are 483 mm x 33 mm x 42 mm (width x depth x height). An E1
panel provides cable distribution for 16 E1s.

Front Panel Diagram

Figure 4-1 Front panel of an E1 panel


R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16

1-8

T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 9-16

Interfaces

Table 4-1 Interface description of an E1 panel


Interface Description Type of Connector

T1–T16 Transmit port of the 1st to 16th E1 ports BNC


(connected to the external equipment)

R1–R16 Receive port of the 1st to 16th E1 ports


(connected to the external equipment)

1–8 1st to 8th E1 ports (connected to an IDU) DB37

9–16 9th to 16th E1 ports (connected to an IDU)

Grounding bolt Connecting a protection ground cable –

NOTE

The interface impedance of each E1 port on an E1 panel is 75 ohms.

For the pin assignments of the E1 port that is connected to an IDU, see Figure 4-2 and refer to
Table 4-2.

Figure 4-2 Pin assignments of an E1 port (E1 panel)

4-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 4 Accessories

Table 4-2 Pin assignments of an E1 port (E1 panel)


Pin Signal Pin Signal

20 1st E1 receiving differential 21 1st E1 transmitting differential


signal (+) signal (+)

2 1st E1 receiving differential 3 1st E1 transmitting differential


signal (–) signal (–)

22 2nd E1 receiving differential 23 2nd E1 transmitting differential


signal (+) signal (+)

4 2nd E1 receiving differential 5 2nd E1 transmitting differential


signal (–) signal (–)

24 3rd E1 receiving differential 25 3rd E1 transmitting differential


signal (+) signal (+)

6 3rd E1 receiving differential 7 3nd E1 transmitting differential


signal (–) signal (–)

26 4th E1 receiving differential 27 4th E1 transmitting differential


signal (+) signal (+)

8 4th E1 receiving differential 9 4th E1 transmitting differential


signal (–) signal (–)

36 5th E1 receiving differential 35 5th E1 transmitting differential


signal (+) signal (+)

17 5th E1 receiving differential 16 5th E1 transmitting differential


signal (–) signal (–)

34 6th E1 receiving differential 33 6th E1 transmitting differential


signal (+) signal (+)

15 6th E1 receiving differential 14 6th E1 transmitting differential


signal (–) signal (–)

32 7th E1 receiving differential 31 7th E1 transmitting differential


signal (+) signal (+)

13 7th E1 receiving differential 12 7th E1 transmitting differential


signal (–) signal (–)

30 8th E1 receiving differential 29 8th E1 transmitting differential


signal (+) signal (+)

11 8th E1 receiving differential 10 8th E1 transmitting differential


signal (–) signal (–)

Others Reserved - -

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 4-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
4 Accessories IDU 605 Hardware Description

4.2 PDU
The PDU is installed on the top of a 19-inch cabinet. The PDU is used to distribute the input
power to the equipment in the cabinet.
4.2.1 Front Panel
There are input power terminals, PGND terminals, output power terminals, and power switches
on the front panel of the PDU.
4.2.2 Functions and Working Principle
The PDU realizes the simple power distribution function. The PDU distributes the input power
to the equipment in a cabinet.
4.2.3 Power Distribution Mode
The IF1A and IF0A boards support two power distribution modes: DC-I and DC-C. The default
power distribution mode is the DC-C mode.

4.2.1 Front Panel


There are input power terminals, PGND terminals, output power terminals, and power switches
on the front panel of the PDU.

Front Panel Diagram

Figure 4-3 PDU front panel


1 2 3 4

1 2
OUTPUT
3 4
A B
1 2
OUTPUT
3 4

ON ON

RTN1(+) RTN2(+) NEG1(-) NEG2(-)

OFF OFF
INPUT
20A 20A 20A 20A 20A 20A 20A 20A

5 6

1. Output power terminals (A) 2. PGND


3. Input power terminals 4. Output power terminals (B)
5. Power switches (A) 6. Power switches (B)

4-4 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 4 Accessories

Interfaces

Table 4-3 PDU interface description


Position Interface Description

Output power + Power output (+)


terminals (A)
- Power output (-)

PGND (Grounding For connecting the protection grounding cable


stud of the two-
hole OT
terminal)

Input power RTN1(+) The 1st power input (+)


terminals
RTN2(+) The 2nd power input (+)

NEG1(-) The 1st power input (-)

NEG2(-) The 2nd power input (-)

Output power + Power output (+)


terminals (B)
- Power output (-)

Power 20 A They are switches for the power outputs. The fuse
switches (A) capacity is 20 A. The switches from the left to the right
correspond to output power terminals 1–4 on the A side
respectively.

Power 20 A They are switches for the power outputs. The fuse
switches (B) capacity is 20 A. The switches from the left to the right
correspond to output power terminals 1–4 on the B side
respectively.

4.2.2 Functions and Working Principle


The PDU realizes the simple power distribution function. The PDU distributes the input power
to the equipment in a cabinet.

Functions
l The PDU supports two inputs of –48 V/–60 V DC power.
l Each input power supply supports four outputs.
l The fuse capacity of the switch of each power output is 20 A.
l The PDU supports the DC-C and DC-I power distribution modes.

Working Principle
The PDU primarily consists of input terminals, output terminals, and miniature circuit breakers
(MCBs). The PDU provides the simple power distribution function for the input power.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 4-5


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
4 Accessories IDU 605 Hardware Description

Figure 4-4 Block diagram of the PDU working principle

OUTPUT A
+
SW1 1
-
+
2
SW2 -
INPUT
+
3
SW3
-
RTN1(+)
+
BGND 4
SW4
-
RTN2(+)
OUTPUT B
NEG1(-) +
SW1 1
BGND -
NEG2(-) +
2
SW2 -
+
SW4 3
-
+
PGND SW4 4
-

4.2.3 Power Distribution Mode


The IF1A and IF0A boards support two power distribution modes: DC-I and DC-C. The default
power distribution mode is the DC-C mode.
The power distribution mode of the PDU is controlled by the short-circuiting copper bar that is
inside the PDU.

DC-C Power Distribution Mode


When the DC-C power distribution mode is used, the short-circuiting copper bar short-circuits
terminal RTN1(+), terminal RTN2(+), and the PGND.

4-6 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 4 Accessories

Figure 4-5 Internal structure of the PDU in the DC-C mode

DC-I Power Distribution Mode


To use the DC-I power distribution mode, remove the short-circuiting copper bar.

Figure 4-6 Internal structure of the PDU in the DC-I mode

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 4-7


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

5 Cables

About This Chapter

This section describes the purpose, appearance, and connections of various cables of the IDU
605.

5.1 Power Cable


The power cable connects the –48 V/–60 V power supply equipment such as the power
distribution box on the top of the cabinet to the IDU 605 to carry the –48 V/–60 V power into
the OptiX RTN 600 system.
5.2 Protection Ground Cable
The IDU, ODU, and E1 panel need to be grounded through their own protection ground cables.
5.3 IF Jumper
The IF jumper is used to connect the ODU and IF cable. The IF jumper is used together with
the IF cable to transmit the IF signal between the ODU and the IDU, O&M signal, and -48 V
power.
5.4 E1 Cable
The E1 cable is available in two types. One type of E1 cable connects the IDU 605 to the external
equipment and the other type of E1 cable connects the IDU 605 to an E1 panel.
5.5 Orderwire Line
The orderwire line is used to connect orderwire phone sets. Both ends of the line use RJ-11
connectors. One end connects the PHONE interface of the IDU 605 and the other end connects
the interface of the orderwire phone set.
5.6 Network Cable
Network cables are used to connect Ethernet equipment. Both ends of a network cable use RJ-45
connectors.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
5 Cables IDU 605 Hardware Description

5.1 Power Cable


The power cable connects the –48 V/–60 V power supply equipment such as the power
distribution box on the top of the cabinet to the IDU 605 to carry the –48 V/–60 V power into
the OptiX RTN 600 system.

Cable Diagram

Figure 5-1 Diagram of the power cable

1 Main label Label1

A-A
3 1 A
W1
W2
4 2
X1 A
Label 2

1. Cable connector: ordinary connector – 4-pin–dual row


Label1: printed with "–48 V" Label2: printed with "BGND"

Cable Connection Table

Table 5-1 Connection Table of the power cable


Cable Connector Wire Color of Core Wire

X1.1 W1 Blue (-48 V power)

X1.3 W2 Black (power ground)

5.2 Protection Ground Cable


The IDU, ODU, and E1 panel need to be grounded through their own protection ground cables.

5.2.1 Protection Ground Cable of the IDU 605


The protection ground cable connects the right ground point of the IDU to the ground point of
the external equipment such as the ground support of a cabinet so that the IDU and other
equipment share the same ground.

5-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

Cable Diagram

Figure 5-2 Diagram of the protection ground cable of the IDU 605
Main label

1 Cable Tie H.S.Tube

1. Bare crimping terminal, OT 2. Bare crimping terminal, OT

Cable Connection Table


None.

5.2.2 E1 Protection Ground Cable of an E1 Panel


The protection ground cable connects the left ground screw of an E1 panel to the ground point
of the external equipment such as the ground support of a cabinet, so that the E1 panel and other
equipment share one ground.

Cable Diagram

Figure 5-3 Diagram of the protection ground cable of an E1 panel


Main label

1. Bare crimping terminal, OT

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
5 Cables IDU 605 Hardware Description

Cable Connection Table


None.

5.3 IF Jumper
The IF jumper is used to connect the ODU and IF cable. The IF jumper is used together with
the IF cable to transmit the IF signal between the ODU and the IDU, O&M signal, and -48 V
power.

The IF jumper is a 2 m RG223 cable. The IF jumper uses a type-N connector at one end to
connect to the IF cable, and a TNC connector at the other end to connect to the IF board.

Cable Diagram

Figure 5-4 View of the IF jumper


1

H.S.tube 2Pcs 2
L=3cm

2000mm

1. RF coaxial cable connector, TNC, male 2. RF coaxial cable connector, type-N, female

Cable Connection Table


None.

5.4 E1 Cable
The E1 cable is available in two types. One type of E1 cable connects the IDU 605 to the external
equipment and the other type of E1 cable connects the IDU 605 to an E1 panel.

5.4.1 From the PO1/PH1 Board to the External Equipment


When the IDU 605 directly inputs/outputs E1 signals from/to the external equipment, use this
E1 cable to connect the IDU 605 to the external equipment. Use a DB44 connector at the end
of the E1 cable that is connected to the IDU 605. Make a connector for the other end that is
connected to the external equipment as required by the site.

The E1 cables that are connected to the external equipment are categorized into 75-ohm coaxial
cables and 120-ohm twisted pair cables. One E1 cable can transmit eight E1 signals.

5-4 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

Cable Diagram

Figure 5-5 Diagram of the 75-ohm cable


A
Pos.1 1

Pos.44
A

Main label
Label 1 Label 1
W1

Label 2 W2 Label 2

1. Cable connector, type-D, 44 male Label 1: W1 (E1: 1 to 4) Label 2: W2 (E1: 5 to 8)

Figure 5-6 Diagram of the 120-ohm cable


A
Pos.1 1

Pos.44
A

Main label
Label 1 Label 1
W1

Label 2 W2 Label 2

1. Cable connector, type-D, 44 male Label 1: W1 (TX1 to TX8) Label 2: W2 (RX1 to RX8)

Cable Connection Table

Table 5-2 75-ohm E1 cable connections

Pin Cable W1 Remark Pin Cable W2 Remark


s s
Core Serial Core Serial
Numbe Numbe
r r

38 Ring 1 R1 34 Ring 1 R5

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-5


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
5 Cables IDU 605 Hardware Description

Pin Cable W1 Remark Pin Cable W2 Remark


s s
Core Serial Core Serial
Numbe Numbe
r r

23 Tip 19 Tip

37 Ring 3 R2 33 Ring 3 R6

22 Tip 18 Tip

36 Ring 5 R3 32 Ring 5 R7

21 Tip 17 Tip

35 Ring 7 R4 31 Ring 7 R8

20 Tip 16 Tip

15 Ring 2 T1 11 Ring 2 T5

30 Tip 26 Tip

14 Ring 4 T2 10 Ring 4 T6

29 Tip 25 Tip

13 Ring 6 T3 9 Ring 6 T7

28 Tip 24 Tip

12 Ring 8 T4 8 Ring 8 T8

27 Tip 7 Tip

Shell Braid Shell Braid

Table 5-3 120-ohm E1 cable connections


Pin Cable W1 Remark Pin Cable W2 Remark
s s
Color Relatio Color Relatio
n n

15 Blue Pair T1 38 Blue Pair R1

30 White 23 White

14 Orange Pair T2 37 Orange Pair R2

29 White 22 White

13 Green Pair T3 36 Green Pair R3

28 White 21 White

12 Brown Pair T4 35 Brown Pair R4

5-6 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

Pin Cable W1 Remark Pin Cable W2 Remark


s s
Color Relatio Color Relatio
n n

27 White 20 White

11 Grey Pair T5 34 Grey Pair R5

26 White 19 White

10 Blue Pair T6 33 Blue Pair R6

25 Red 18 Red

9 Orange Pair T7 32 Orange Pair R7

24 Red 17 Red

8 Green Pair T8 31 Green Pair R8

7 Red 16 Red

Shell Braid Shell Braid

5.4.2 From the PO1/PH1 Board to the E1 Panel


When the IDU 605 uses an E1 panel as the DDF, use this E1 cable to connect the IDU 605 to
the E1 panel. Use a DB44 connector at the end of the E1 cable that is connected to the IDU 605,
and use a DB37 connector at the other end that is connected to the E1 panel.
Each E1 cable can transmit eight E1 signals. The interface impedance of the E1 cable is 75 ohms.

Cable Diagram

Figure 5-7 Diagram of the E1 cable that connects a PO1/PH1 board to an E1 panel
A B 2
Pos.1 1 Pos.1

Pos.44 Pos.37

A B

1500 mm

1. Cable connector, type-D, 44 male 2. Cable connector, type-D, 37 male

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-7


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
5 Cables IDU 605 Hardware Description

Cable Connection Table

Table 5-4 Connection table of the E1 cable that connects a PO1/PH1 board to an E1 panel
Connector Connector Remarks Connector Connector Remarks
X1 X2 X1 X2

X1.38 X2.20 R1 X1.34 X2.36 R5

X1.23 X2.2 X1.19 X2.17

X1.37 X2.22 R2 X1.33 X2.34 R6

X1.22 X2.4 X1.18 X2.15

X1.36 X2.24 R3 X1.32 X2.32 R7

X1.21 X2.6 X1.17 X2.13

X1.35 X2.26 R4 X1.31 X2.30 R8

X1.20 X2.8 X1.16 X2.11

X1.15 X2.21 T1 X1.11 X2.35 T5

X1.30 X2.3 X1.26 X2.16

X1.14 X2.23 T2 X1.10 X2.33 T6

X1.29 X2.5 X1.25 X2.14

X1.13 X2.25 T3 X1.9 X2.31 T7

X1.28 X2.7 X1.24 X2.12

X1.12 X2.27 T4 X1.8 X2.29 T8

X1.27 X2.9 X1.7 X2.10

Shell Braid Shell Braid

5.5 Orderwire Line


The orderwire line is used to connect orderwire phone sets. Both ends of the line use RJ-11
connectors. One end connects the PHONE interface of the IDU 605 and the other end connects
the interface of the orderwire phone set.

5-8 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

Cable Diagram

Figure 5-8 Diagram of the orderwire wire


1 Main Label

6 6

1 1
X1 X2

1. Orderwire wire, RJ-11 connector

Cable Connection Table

Table 5-5 Orderwire wire connections


Connector X1 Connector X2 Core

X1.3 X2.3 Tip

X1.4 X2.4 Ring

5.6 Network Cable


Network cables are used to connect Ethernet equipment. Both ends of a network cable use RJ-45
connectors.
RJ-45 connectors have two types of interfaces. The first type is the medium dependent interface
(MDI) used by terminal equipment such as network card. Refer to Table 5-6. The second type
is the MDI-X used by network equipment. Refer to Table 5-7.

Table 5-6 Pin assignments of the MDI


Pin Signal Function

1 TxData+ Transmitting data (+)

2 TxData- Transmitting data (-)

3 RxData+ Receiving data (+)

6 RxData- Receiving data (-)

4, 5, 7, 8 Reserved -

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-9


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
5 Cables IDU 605 Hardware Description

Table 5-7 Pin assignments of the MDI-X


Pin Signal Function

1 RxData+ Receiving data (+)

2 RxData- Receiving data (-)

3 TxData+ Transmitting data (+)

6 TxData- Transmitting data (-)

4, 5, 7, 8 Reserved -

Straight through cables are used between MDI and MDI-X interfaces, and crossover cables are
used between MDI interfaces or between MDI-X interfaces. The only difference between the
two network cables are the connections.
The ETH and ETH-HUB ports on IDU support MDI/MDI-X auto-sensing. Thus, both straight
through cables and crossover cables can be used between these ports and the MDI/MDI-X
interfaces.

Cable Diagram

Figure 5-9 Diagram of the network cable


1
Label 1 Main Label Label 2

8 8

1 1

1. Network interface connector, RJ-45

Cable Connection Table

Table 5-8 Cable connection of the straight through cable


Connector X1 Connector X2 Color Relation

X1.1 X2.1 White/Orange Pair

X1.2 X2.2 Orange

X1.3 X2.3 White/Green Pair

X1.6 X2.6 Green

X1.4 X2.4 Blue Pair

X1.5 X2.5 White/Blue

X1.7 X2.7 White/Brown Pair

5-10 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description 5 Cables

Connector X1 Connector X2 Color Relation

X1.8 X2.8 Brown

Table 5-9 Cable connection of the crossover cable


Connector X1 Connector X2 Color Relation

X1.6 X2.2 Orange Pair

X1.3 X2.1 White/Orange

X1.1 X2.3 White/Green Pair

X1.2 X2.6 Green

X1.4 X2.4 Blue Pair

X1.5 X2.5 White/Blue

X1.7 X2.7 White/Brown Pair

X1.8 X2.8 Brown

Issue 01 (2008-06-20) Huawei Proprietary and Confidential 5-11


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description A Indicators and Power Consumption for Quick Reference

A Indicators and Power Consumption for


Quick Reference

Indicators

Table A-1 Description of the indicators of the IDU 605 1A/1B


Indicat Status Meaning
or

PWR On (green) The power supply is working normally.

On (red) The +3.3 V power supply or the –48 V power


supply is faulty.

Off There is no power access.

IDU On (green) The IDU works normally.

On (red) A critical or major alarm occurs in the


services.

On (yellow) A minor or warning alarm occurs in the


services.

On for 100 ms and off for 100 ms When the board is being powered on or being
alternately (green) reset, the software is being loaded.

On for 500 ms and off for 500 ms The board is in the BIOS holdover state. The
alternately (green) NE software does not exist or is not running.

ODU On (green) The ODU works normally.

On (red) A critical or major alarm occurs in the ODU,


or the ODU has no power access.

On (yellow) A minor or warning alarm occurs in the ODU.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential A-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
A Indicators and Power Consumption for Quick Reference IDU 605 Hardware Description

Table A-2 Description of the indicators of the IDU 605 2B


Indicat Status Meaning
or

PWR On (green) The power supply is working normally.

On (red) The +3.3 V power supply or the –48 V power


supply is faulty.

Off There is no power access.

IDU On (green) The IDU works normally.

On (red) A critical or major alarm occurs in the


services.

On (yellow) A minor or warning alarm occurs in the


services.

On for 100 ms and off for 100 ms When the board is being powered on or being
alternately (green) reset, the software is being loaded.

On for 500 ms and off for 500 ms The board is in the BIOS holdover state. The
alternately (green) NE software does not exist or is not running.

ACT1 On (green) IF 1+1 protection is in the switching state


(that is, works in the standby system).

Off IF 1+1 protection is in the normal state (that


is, works in the active system).

ACT2 On (green) IF 1+1 protection is in the normal state (that


is, works in the active system).

Off IF 1+1 protection is in the switching state


(that is, works in the standby system).

ODU1 On (green) The standby ODU works normally.

On (red) The standby ODU is faulty or has no power


access.

On (yellow) A minor or warning alarm occurs in the


standby ODU.

ODU2 On (green) The active ODU works normally.

On (red) The active ODU is faulty or has no power


access.

On (yellow) A minor or warning alarm occurs in the active


ODU.

A-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description A Indicators and Power Consumption for Quick Reference

Power Consumption

Table A-3 Power consumption of the IDU 605


Equipment Power Consumption

IDU 605 1A < 17 W

IDU 605 1B < 18 W

IDU 605 2B < 31 W

Issue 01 (2008-06-20) Huawei Proprietary and Confidential A-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description B Glossary

B Glossary

Numerics
1U Standard EIA Rack Unit (44 mm/1.75 in.)
1+1 A microwave link protection system composed of one working channel and
protection one protection channel. Two ODUs and two IF boards are used at each end
of a microwave link.

A
ATPC Automatic Transmit Power Control. A method of adjusting the transmit
power based on fading of the transmit signal detected at the receiver.

B
Bit error An error occurs to some bits in the digital code stream after being received,
judged, and regenerated, thus damaging the quality of the transmitted
information.

D
DC-C The power system with the GND and PGND connected.
DC-I The power system with the GND and PGND isolated.
Digital Digital modulation controls the changes in amplitude, phase, and frequency
modulation of the carrier based on the changes in the baseband digital signal, so that the
information can be transmitted by the carrier. The digital modulation methods
of the OptiX RTN 600 include QPSK, 16QAM, and 128QAM.

Issue 01 (2008-06-20) Huawei Proprietary and Confidential B-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
B Glossary IDU 605 Hardware Description

Equalization A method of avoiding selective fading of frequencies. Equalization can


compensate for the changes of amplitude frequency caused by frequency
selective fading.

F
FD Frequency Diversity. Two or more microwave frequencies with certain
frequency space are used to transmit/receive the same signal and selection is
then performed between the two signals to ease the impact of fading.
FEC Forward Error Correction. A bit error correction technology that adds to the
payload at the transmit end the correction information based on which the bit
errors generated during transmission are corrected at the receive end.

I
IDU Indoor Unit. The indoor unit implements accessing, multiplexing/
demultiplexing, and IF processing for services.
IF Intermediate Frequency. IF is the transitional frequency between the
frequencies of a modulated signal and an RF signal.
IF board A board that processes microwave services.

N
Non- The RTN 600 microwave station on which the transmitted frequency is lower
primary than the received frequency.
station

O
ODU Outdoor Unit. The outdoor unit implements frequency conversion and
amplification for RF signals.
Orderwire Orderwire is a channel that provides voice communications among operation
engineers or maintenance engineers of different stations.

P
PDH Plesiosynchronous Digital Hierarchy. A multiplexing scheme of bit stuffing
and byte interleaving. It multiplexes the minimum rate 64 kit/s into the 2
Mbit/s, 34 Mbit/s, 140 Mbit/s and 565 Mbit/s rates.
Primary The RTN 600 microwave station on which the transmitted frequency is higher
station than the received frequency.

B-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description B Glossary

Primary Rapid Spanning Tree Protocol. The protocol is an evolution of the Spanning
station Tree Protocol, providing for faster spanning tree convergence after a
topology change.

S
SD Space Diversity. Two or more antennas separated by a specific distance
transmit/receive the same signal and selection is then performed between the
two signals to ease the impact of fading. Currently, only receive SD is used.

T
T2000 A subnet management system (SNMS). In the telecommunication
management network architecture, the T2000 is located between the NE level
and network level, which can supports all NE level functions and part of the
network level management functions.
Tributary A board that processes tributary services.
board

Issue 01 (2008-06-20) Huawei Proprietary and Confidential B-3


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description C Acronyms and Abbreviations

C Acronyms and Abbreviations

A
AGC Automatic Gain Control
AIS Alarm Indication Signal
ASK Amplitude Shift Keying
ATPC Automatic Transmit Power Control

B
BER Bit Error Rate
BIOS Basic Input/Output System

C
CPU Central Processing Unit
CRC Cyclic Redundancy Check

D
DC Direct Current
DCC Data Communications Channel
DDF Digital Distribution Frame
DFE Decision Feedback Equalizer

E
ECC Embedded Control Channel
ETSI European Telecommunications Standards Institute

Issue 01 (2008-06-20) Huawei Proprietary and Confidential C-1


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
C Acronyms and Abbreviations IDU 605 Hardware Description

F
FD Frequency Diversity
FEC Forward Error Correction
FFF Feed Forward Equalizer Filter
FPGA Field Programmable Gate Array

H
HDB3 High Density Bipolar of order 3
HSB Hot Standby

I
IDU Indoor Unit
IF Intermediate Frequency
IP Internet Protocol
ITU-T International Telecommunication Union -
Telecommunication Standardization Sector

M
MAC Medium Access Control
MDI Medium Dependent Interface
MODEM MOdulator-DEModulator

N
NE Network Element
NM Network Management

O
OAM Operation, Administration and Maintenance
ODU Outdoor Unit

P
PCB Printed Circuit Board

C-2 Huawei Proprietary and Confidential Issue 01 (2008-06-20)


Copyright © Huawei Technologies Co., Ltd
OptiX RTN 600 Radio Transmission System
IDU 605 Hardware Description C Acronyms and Abbreviations

PDH Plesiochronous Digital Hierarchy


PRBS Pseudo-random binary sequence

Q
QAM Quadrature Amplitude Modulation
QPSK Quadrature Phase Shift Keying

R
RF Radio Frequency
RSL Received Signal Level
RSSI Received Signal Strength Indicator
RTN Radio Transmission System

S
SD Space Diversity

T
TCM Trellis Coded Modulation schemes