Вы находитесь на странице: 1из 2

Hellgate Appliance

HG-100
Introduction Step 3: Description of the LCD screen options
4. Press ENTER to confirm the settings after each step. A description of all the LCD screen options follows:
This guide is designed for quickly and easily installing the eSafe Hellgate 100 Selecting the product type 5. At the end of the wizard, the eSafe operating system and software will be • Start eSafe: Starts the eSafe services.
Appliance, and assumes basic networking skills. This guide includes instructions The appliance is configured via the LCD screen. reinstalled on the hard drive (approx. 10-15 min) and the appliance will reload • Stop eSafe: Stops the eSafe services.
for installing the appliance with eSafe Web Bridge Mode, eSafe Mail, and eSafe Use the UP and DOWN arrow buttons to select parameters. • Restart: Reboots the appliance.
with defined product settings. The appliance is now ready to be physically
Web SSL. Detailed instructions for these and other installation modes are available • Shutdown: Shuts down the operating system, without powering off.
Press ENTER to accept/confirm a selection, and or ESC to go back a step. placed in the network.
at: www.esafe.com/support/eSafeDocuments.asp • Create Backup: Backs up the appliance settings and eSafe configuration on
1. Use the “Up” and “Down” arrows to navigate to the Select Product menu. 6. Shut down the appliance via the LCD screen. Disconnect the power cable in the appliance’s internal flash disk.
order to place the appliance in its physical location.
Step 5:
Connecting the appliance to the network
Press ENTER. 1. Place the appliance in its physical location. • Restore Backup: Restores the appliance settings and eSafe configuration
2. Connect the power cable. from the appliance’s internal flash disk.
Getting started with your Hellgate Appliance consists of the following steps: 2. Select one of the following product types:
3. Connect the appliance to the network as follows: • Set Date or Time: Sets the date, time, and time zone.
• Unpacking and familiarizing yourself with the appliance. • eSafe Gateway • Network Settings: Defines the IP address, network mask, default gateway,
• Connecting the appliance to the power supply. • eSafe Web • For eSafe Gateway/Web:
and DNS
• Selecting the product type. • eSafe Mail • Use a cross-over cable to connect Port 1 of the appliance to the default • Reset to F/D: Re-images the appliance and loads the factory defaults;
• Defining network settings. gateway (firewall) server. the hard drive is formatted. You can then restore an existing back-up,
• eSafe Web SSL
• Connecting the appliance to the network. • Use a regular network cable to connect Port 2 to the internal LAN switch. or re-install the appliance.
3. Press ENTER to confirm the selection. The following message appears:
• Managing the appliance via the management console. • Connect the management port to the internal LAN switch. • Select Product: Allows selecting the eSafe product.
This guide also includes a description of the LCD options. • For eSafe Mail/Web SSL: Use a network cable to connect the MNG (Management)
port to the internal LAN switch. Advanced operations
Step 1: Advanced fine tuning can be performed via the eSafe Appliance Manager, as follows:
4. Switch on the appliance. (The power button is located on the back panel.) 1. Select one of the following options:
Unpacking and familiarizing yourself with the appliance
The “eSafe Running” message appears and the appliance starts inspecting traffic. • If you have not yet assigned an IP address to the appliance's port (first time
The appliance package contains the following: You will be prompted to define the settings required for the product you selected
Note: The appliance includes a 30-day evaluation license. operation), connect a crossover cable to the management port (MNG) and
• HG-100 Appliance. to work in the network. Continue with Step 4.
Contact your reseller to obtain a permanent license as soon as possible. connect to: https://10.0.0.1:37233
• Power cable. • If you have already assigned an IP address to the appliance's port, browse
• CD-ROM with the eConsole management software and product documentation. to: https://<IP. address>:37233, where IP address is the IP address of the appliance
• Printed brochures. Step 4: Step 6:
The eSafe Appliance Status page appears
2. Open Internet Explorer and connect to: https://<IP address>:37233, where IP address
Defining network settings Managing the appliance via the management console is the IP address of the appliance. The eSafe Appliance Status page appears.
Follow the instructions below to view and edit the network settings. If this is the
1. On the administrator machine, install the eConsole management application
first time you are configuring the appliance, you will be forced to define these
Port 1 (Eth2) Connects to the default gateway (firewall) from the CD-ROM.
settings automatically.
Port 2 (Eth3) Connects to the internal LAN switch 2. In eConsole, add the eSafe appliance to the list of machines. Use the IP address 3. Edit the configuration as necessary, or select Settings | Configuration Wizard to
1. Define the IP address(es) as follows:
MNG (Eth0) Management port - Connects to the internal LAN switch defined via the LCD screen. change the product type. Refer to the relevant product’s installation guide for details.
• For eSafe Gateway/Web: Define the management IP address for managing
B Reboots the appliance
and updating the appliance. Hellgate 100 specifications
• For eSafe Mail/Web SSL: Define the appliance’s “access” IP address that will CPU Intel Pentium 4, 2.8GHz
Step 2:
be used for management and scanning traffic. Memory 1GB (DDR 266Mhz)
Connecting to the power supply
Ports 2x10/100Mb Onboard NICs, 2x10/100/1000Mb Bypass NICs, USB2.0,VGA
1. Use the supplied power cord to connect the appliance’s power socket to a
Storage 160GB IDE HDD, 512MB CF
working power outlet.
LCD Panel 2x16 characters, 4 buttons
2. Switch the appliance on. The power button is located on the back panel.
The LCD screen lights up. Power Full-range 220W ATX PSU
2. Press ENTER to confirm the settings. Dimension 430 (W) x 390 (D) x 44 (H) mm;
3. Wait for the boot process to complete. This may take a few minutes.
At the end of the boot process, the following message appears: 3. Define the network mask, default gateway, and domain name server settings 16.83" (W) x 15.35" (D) x 1.73"
3. Fine-tune the configuration to suit the needs of your network.
in the same way as the IP address. Weight 6.9 Kg
4. Make sure you define the alert recipients and internal mail server.
• For eSafe Gateway: Define the IP address for managing and subnet for the Operating Temp. 5 to 35°C
Detailed instructions for performing these actions are available in the
internal network, and the IP address and subnet for the external network Certifications CE/FCC/UL
eConsole Administrator’s Guide.
(firewall). Build 6.1.058
If you have any questions regarding installation of the appliance, visit
http://wts.aladdin.com or http://www.aladdin.com/support for local
contact information, where applicable.

Hellgate Appliance

For more contact information, visit: www.Aladdin.com/contact


HG-100
North America T: 1-800-562-2543, 1-847-818-3800
UK T: +44-1753-622-266
Germany T: +49-89-89-4221-0
France T: +33-1-41-37-70-30
Benelux T: +31-30-688-0800
Spain T: +34-91-375-99-00
India T: +91-22-254-224-18
Italy T: +39(333)9356711
Israel T: +972-3-636-2222
China T: +86(138)18184444
Brazil T: +55(11)5539-5688
Japan T: +81-426-607-191
All other inquiries T: +972-3-636-2222
© 4/2007 Aladdin Knowledge Systems, Ltd. All rights reserved. Aladdin and eSafe are registered trademarks of Quick Start Guide