Submersible pumps
50/60 Hz
Contents
Communication, CU 301
CU 301, control unit 18
R100 menu structure for the CU 301 19
R100 menus for CU 301 20
Communication, CU 300
CU 300 Control unit 21
R100 menu structure for the CU 300 22
R100 menus for CU 300 23
Examples of R100 displays 24
Alarm indication 25
Benefits of CU 300/R100 25
Pump selection
Determining head and flow 26
Pump sizing 27
Variable speed 28
Curve conditions 28
Selecting the right pump for the SQE
constant-pressure system 29
Selection of pressure tank 30
2
General data SQ, SQ-N, SQE, SQE-N
Performance range
p H
[kPa] [m]
SQ
2000 200 SQ - N
SQE
SQE - N
150 ISO 9906 Annex A
1000 100
900
800 80
700
600 60
500
SQ 1 SQ 2 SQ 3 SQ 5
400 40
300 30
200 20
SQ 7
15
100 10
TM02 9976 4104
0 1 2 3 4 5 6 7 8 Q [m³/h]
3
General data SQ, SQ-N, SQE, SQE-N
SQ submersible pumps The SQE pump can operate without the CU 300 or the
CU 301. However, in this situation it will not offer all the
SQ pumps are suitable for both continuous and inter-
features available when the pump is connected to a
mittent operation for a variety of applications:
CU 300 or CU 301. The CU 300 and CU 301 provide full
• Domestic water supply control of the SQE pumps. In case of a pump fault, an
• Small waterworks alarm will be indicated on the front of the CU 300 or
• Irrigation CU 301. The R100 enables monitoring of the installa-
tion and changing of the factory settings.
• Tank applications
• Pressure boosting.
Pump and motor range
Note: For other applications, please contact Grundfos.
Product Description Material
SQ pumps offer the following features:
3 Stainless steel
SQ pump (1, 2, 3, 5, and 7 m /h)
• Dry-running protection DIN 1.4301, AISI 304
Stainless steel
• High efficiency of pump and motor SQ-N pump (1, 2, 3, 5, and 7 m3/h)
DIN 1.4401, AISI 316
• Wear resistance MS 3 motor
Single-phase Stainless steel
Max. 1.85 kW DIN 1.4301, AISI 304
• Protection against upthrust
Single-phase Stainless steel
MS 3-NE motor
• Soft starter Max. 1.85 kW DIN 1.4401, AISI 316
Single-phase Stainless steel
• Overvoltage and undervoltage protection MSE 3 motor
Max. 1.85 kW DIN 1.4301, AISI 304
• Overload protection MSE 3-NE mo- Single-phase Stainless steel
tor Max. 1.85 kW DIN 1.4401, AISI 316
• Overtemperature protection.
Additionally the SQE pumps offer: Pipe connection
• Variable speed
Pump type Threaded connection
• Electronic control and communication. SQ 1, SQ 2, SQ 3 Rp 1¼
The SQ pump is a submersible pump which is available SQ 5, SQ 7 Rp 1½
in four different versions:
• SQ
Type key
• SQ-N Example SQ E 2 -55
• SQE
Type range
• SQE-N.
Blank = Basic version
The motors are based on the most recent technology E = Electronic control
within permanent magnets. This technology is the main and communicaion
reason for the high efficiency of the motors. The motors
Rated flow (in m3/h)
have a built-in electronic unit containing a frequency
converter featuring soft start.
Head at rated flow (in m)
The SQ pump is fitted with a single-phase Grundfos
MS 3 or MS 3-NE motor and by means of the built-in Material code:
Blank = Stainless steel DIN W.-nr. 1.4301
frequency converter it is driven at a constant speed.
N = Stainless steel DIN W.-nr. 1.4401
The SQE pump is fitted with a single-phase Grundfos
MSE 3. The MSE 3 motor can communicate with the Pumped liquids
Grundfos control units CU 300 and CU 301, which can SQ and SQE pumps are designed for pumping thin,
be operated by means of Grundfos remote control clean, non-aggressive and non-explosive liquids, not
R100. containing solid particles or fibres. SQ and SQE are
The SQE pump features variable speed which is suitable for pumping liquids with a content of sand up to
offered through frequency control. As a consequence, 50 g/m3. A higher content of sand will shorten pump life.
the pump can be set to operate in any duty point in the
range between the pump min. and max. performance Operating conditions
curves.
Liquid temperature:
The CU 301 is specially developed for applications
where a constant pressure is needed. Flow velocity past motor Max. liquid temperature
0.0 m/s (Free convection) 30°C
Min. 0.15 m/s 40°C
4
Features and benefits SQ, SQ-N, SQE, SQE-N
Dry-running protection
H
The SQ and SQE pumps are protected against dry run-
ning. A value of Pcut-out ensures cut-out of the pump in
case of lack of water in the borehole thus preventing a
burnout of the motor.
Q
60 Conventional 1 ph.
Conventional 1 ph
High motor efficiency
Wear resistance
The SQ pump design features impellers which are not
fastened to the shaft ("floating"). Each impeller has its
own tungsten carbide/ceramic bearing. The construc-
5
Features and benefits SQ, SQ-N, SQE, SQE-N
Overload protection
Exposure of the pump to heavy load causes the current
consumption to rise. The motor will automatically com-
pensate for this by reducing the speed to 3000 rpm.
Further overload will lead to stop.
If the rotor is being prevented from rotating this will
automatically be detected and the power supply cut out.
Consequently, no extra motor protection is needed.
Overtemperature protection
A permanent magnet motor gives off very little heat to
its surroundings. In combination with an efficient inter-
nal circulation system leading the heat away from the
rotor, stator and bearings, this fact ensures optimum
operating conditions for the motor.
As an extra protection, the electronic unit has a built-in
temperature sensor. When the temperature rises too
high, the motor is cut out; when the temperature has
dropped, the motor is automatically cut in again.
Reliability
The motors have been constructed with a view to high
reliability and have the following features:
• Tungsten carbide / ceramic bearings.
• Thrust bearings protecting against downthrust.
• Product life time equal to conventional AC motors.
6
Features and benefits SQ, SQ-N, SQE, SQE-N
Variable speed
The MSE 3 motor enables continuously variable speed
control within the 3000 and 10700 rpm. The pump can
be set to operate in any duty point in the range between
the 3000 and 10700 rpm performance curves of the
pump. Consequently, the pump performance can be
adapted to any specific requirement.
The variable speed control facility requires the use of
the CU 300 or CU 301 control unit and the R100. See
page 28.
For the calculation of pump speed the program "SQE
Speed Calculation" is available on CD-ROM as an
accessory, see page 49. On the basis of a required
head and flow the speed of the motor is calculated. Fur-
thermore, the specific pump performance curve can be
illustrated.
Service
The modular pump and motor design facilitates instal-
lation and service. The cable and the plug are fitted to
the pump with screws which enables replacement.
7
Application examples SQ, SQ-N, SQE, SQE-N
1 Pump, SQ
2 Cable
3 Cable clips
4 Pressure tank*
17
4 12 Pressure switch
14 Pressure gauge
12
14
17 Isolating valve
18 Tap
20 20 Mains switch
18
21 21 Mains connection, 1 x 200-240 V, 50/60 Hz
17
22 Riser pipe
30 Straining wire
31 Wire clamp
31
22
30
31
min. 0.5 m
8
Application examples SQ, SQ-N, SQE, SQE-N
SQ with Presscontrol (with/without The setting of the pressure tank precharge pressure
depends on the water level (difference of height
pressure tank) between water level and the Presscontrol).
Functioning and benefits The setting of the flow pipe pressure at the pressure
If water is consumed the SQ pump is cut in via the tank depends on the water level (difference of height
Presscontrol. The pressure tank is fitted between the between water level and Presscontrol) according to the
SQ and the Presscontrol. In an installation with a pres- following table:
sure tank, water is supplied as soon as the tap is
opened. It means that the pressure tank takes over Difference of height Flow pipe pressure in pressure
[m] tank [bar]
water supply during the smooth start up of the SQ pump 0 1.22
(about 3 seconds). 10 1.0
When the water consumption stops (flow = 0), the pump 20 0.77
30 0.56
will continue operating for 10 seconds building up pres-
sure in the pressure tank.
In the case of leakage with less than 50 l/hour the pump
is not put into operation by the Presscontrol flow switch
but by the pressure switch (Presscontrol PC 15, switch-
on pressure = 1.5 bar). In case the water consumption
is higher than 50 l/hour, the pump will be in continuous
operation.
1 Pump, SQ
2 Cable
3 Cable clips
4 Pressure tank
Difference of heigh 14 Pressure gauge
max. 13 m 17 Isolating valve
24 18 Tap
4
26 22 Riser pipe
17 18 l 23 Presscontrol PC 15 available with/without plug
18
14
25 24 Union
23 25 Plug
17 24
26 Mains connection, 1 x 200-240 V, 50/60 Hz for PC 15
30 Straining wire
31 Wire clamp
min. 0.5 m
9
Application examples SQ, SQ-N, SQE, SQE-N
Features and benefits At low flow, lower than approximately 0.18 m3/h, the
The system maintains a constant pressure within the pressure will drop slowly. When the pressure in the tank
maximum pump performance in spite of a varying water is 0.5 bar below setpoint, the pump will start. The pump
consumption. will run until the pressure is 0.5 bar above setpoint. This
way of operation is called on/off operation.
The pressure is registered by the pressure sensor and
transmitted to the CU 301. The CU 301 adjusts the At flow higher than approximately 0.18 m 3/h the pres-
pump performance accordingly. sure will drop quickly and the pump will start immedi-
ately and maintain constant pressure.
During operation the CU 301 will regulate the pump
speed to maintain a constant pressure. If there is no
consumption, the pump will fill up the tank and stop
after a few seconds.
1 Pump, SQE
2 Cable
3 Cable clips
4 Pressure tank, 8 litres
5 Control unit, CU 301
10 Pressure sensor, 0-6 bar
14 Pressure gauge
18 Tap
21 Mains connection, 1 x 200-240 V, 50/60 Hz
22 Riser pipe
30 Straining wire
31 Wire clamp
min. 0.5 m
10
Application examples SQ, SQ-N, SQE, SQE-N
Features and benefits At low flow, lower than approximately 0.18 m3/h, the
The system maintains a constant pressure within the pressure will drop slowly. When the pressure in the tank
maximum pump performance in spite of a varying water is 0.5 bar below setpoint, the pump will start. The pump
consumption. will run until the pressure is 0.5 bar above setpoint. This
way of operation is called on/off operation.
The pressure is registered by means of the pressure
sensor and transmitted to the CU 301. The CU 301 At flow higher than approximately 0.18 m 3/h the pres-
adjusts the pump performance accordingly. sure will drop quickly and the pump will start immedi-
ately and maintain constant pressure.
During operation the CU 301 will regulate the pump
speed to maintain a constant pressure. If there is no
consumption, the pump will fill up the tank and stop
after a few seconds.
1 Pump, SQE
2 Cable
3 Cable clips
4 Pressure tank, 8 litres
5 Control unit, CU 301
10 Pressure sensor, 0-6 bar
14 Pressure gauge
18 Sprinkler system
21 Mains connection, 1 x 200-240 V, 50/60 Hz
22 Riser pipe
30 Straining wire
31 Wire clamp
min. 0.5 m
11
Application examples SQ, SQ-N, SQE, SQE-N
5
R100
R100
1 Pump, SQE
21 29
2 Cable
3 Cable clips
5 Control unit, CU 300
11 Level sensor
21 Mains connection, 1 x 200-240 V, 50/60 Hz
22 Riser pipe
29 Remote control, R100
31 30 Straining wire
31 Wire clamp
22 Warning (Max.)
2
Desired level
3
Recommended min. 0.5 m
30 Warning (Min.)
31
11
12
Application examples SQ, SQ-N, SQE, SQE-N
5 5
R100
R100 R100
R100
21 29 21 29
2 3
22
Max. (start)
27
11 Min. (stop)
Recommended
1 min. 0.5 m 11
22
2
3 Recommended
30
min. 0.5 m
31
1
1 Pump, SQE
2 Cable
3 Cable clips
5 Control unit, CU 300
11 Level sensor
21 Mains connection, 1 x 200-240 V, 50/60 Hz
22 Riser pipe
27 Flow sleeve with strainer and supporting brackets
13
Application examples SQ, SQ-N, SQE, SQE-N
1 Pump, SQE
2 Cable
5 R100 3 Cable clips
R100
29 5 Control unit, CU 300
21 11 Level sensor
21 Mains connection, 1 x 200-240 V, 50/60 Hz
22 Riser pipe
27 Flow sleeve with strainer and supporting brackets
Max. (stop) 29 Remote control, R100
22
Min. (start)
11
11
Max. (start)
27
1 Min. (stop)
14
Application examples SQ, SQ-N, SQE, SQE-N
CU 300
R100
SQE
15
Application examples SQ, SQ-N, SQE, SQE-N
5 32
1 SQE pump
2 Cable
3 Cable clips
5 Control unit, CU 300
21 Mains connection1 x 220-240 V, 50/60 Hz
22 Riser pipe
30 Stainless steel straining wire
21 31 Stainless steel wire clamps, 2 per lifting eye
32 Potentiometer, SPP1
22
Recommended
2
min. 0.5 m
30
31
16
Application examples SQ, SQ-N, SQE, SQE-N
1 Pump, SQ
2 Cable
3 Cable clips
6 Aerator with non-return valve
12 Pressure switch
13 Air vent
12
24 14 Pressure gauge
17
17 Isolating valve
14 20 Mains switch
21 Mains connection, 1 x 200-240 V, 50/60 Hz
13
22 Riser pipe
28 17 24 Union
28 Pressure tank
20 30 Straining wire
21
31 Wire clamp
22
30
TM01 2988 2898
31
min. 0.5 m
17
Communication, CU 301 SQ, SQ-N, SQE, SQE-N
5. Dry-running indicator
6. Service needed in case of:
232 114
– No contact to pump
– Overvoltage
bar
– Undervoltage 5.0
4.5
4.0
3.5
– Overtemperature
195
– Overload
18
Communication, CU 301 SQ, SQ-N, SQE, SQE-N
Start
Set
Contrast
Light
1.7 3.7
1.8 3.8
3.9
3.10
19
Communication, CU 301 SQ, SQ-N, SQE, SQE-N
1. Operation
1.1 Setpoint setting.
1.2 Selection of operating mode.
1.3 Alarm indication.
2. Status
The indication of:
2.1 Actual operating mode.
2.2 Actual pressure.
2.3 Actual motor speed.
2.4 Actual motor temperature.
2.5 Actual power input and accumulated motor power
consumption.
2.6 Accumulated number of operating hours and
accumulated number of starts.
3. Installation
3.1 Sensor parameters.
3.2 Choice of sensor.
3.3 Setting of maximum pressure setpoint.
3.4 Setting of automatic restart time.
3.5 Setting of the dry-running stop limit.
3.6 Setting of the maximum motor speed.
3.6 Setting of the maximum motor speed.
3.7 Setting of the cut-in motor speed.
3.8 Activating or deactivating the on/off-button and
the buttons for system pressure setting on the
CU 301.
3.9 Indication of pump operation.
3.10 Allocation of number.
Status report
All settings and measured values can be transferred to
a portable printer via wireless infrared communication
and be printed in a status report.
IR- printer
IR - Drucker
TM00 7982 2293
R100
R 100
OK
20
Communication, CU 300 SQ, SQ-N, SQE, SQE-N
• No contact
Fieldbus
• Overvoltage entry
21
Communication, CU 300 SQ, SQ-N, SQE, SQE-N
Start
Set
Contrast
Light
3.10 4.10
3.11
22
Communication, CU 300 SQ, SQ-N, SQE, SQE-N
3. Limits
The setting of: IR- printer
IR - Drucker
3.1 Sensor 1 parameters.
23
Communication, CU 300 SQ, SQ-N, SQE, SQE-N
2.6
The value of operating hours and the number of starts
are values accumulated from the time of installation
1.1 and they cannot be reset.
From factory, the pump is set to maximum speed,
10,700 rpm. R100 makes it possible to reduce the Both values are stored in the motor electronics, and
pump speed by changing the setpoint. The speed can they are kept even if the CU 300 is replaced.
be set to 3000 - 10,700 rpm, at 100 rpm intervals. The number of operating hours is registered every two
The unit of the setpoint is automatically changed minutes of continuous operation.
according to the unit of the sensor connected to sensor
input no. 1.
Menu LIMITS
Example: Sensor input no. 1 is connected to a pres- Sensor 1
sure sensor using the unit metre (m) and the range 0 -
60. Consequently, the setpoint of display 1.1 can be set
to between 0 - 60 m.
Menu STATUS
The displays appearing in this menu are status displays
only. It is not possible to change settings in this menu. 3.1
Accumulated flow The setting of sensor 1.
Depending on the type of sensor, the following settings
can be made:
• Sensor outputs:
– (not active), 0-10 V, 2-10 V, 0-20 mA, 4-20 mA.
• Setting range unit: m3/h, m, %, GPM, ft.
• Sensor minimum value: 0 - 249 (0,1,2,3.....249)
2.9
• Sensor maximum value: 1 - 250 (1,2,3,4.....250)
In display 2.9 the water quantity (m3) pumped is shown.
The value shown is the accumulated flow registered by
the sensor selected in display 3.11.
The power used to pump 1 m3 is shown in the display
as energy per m3 (kWh/m 3).
It is possible to read the status of the accumulated flow
and energy per m3 at any time.
24
Communication, CU 300 SQ, SQ-N, SQE, SQE-N
Alarm indication
The CU 300 offers the following alarm indications
Benefits of CU 300/R100
Alarm Description The following are no longer required
Provides knowledge of contact between the SQE pump and the CU
No contact –
300.
Overvoltage The supply voltage is measured. Overvoltage relay.
Undervoltage The supply voltage is measured. Undervoltage relay.
Dry running Provides dry-running protection of the pump. Level relay, electrodes, cables.
Ensures pump operation at a moderate undervoltage and overload,
Speed reduction Urgent need for service.
thereby ensuring that the motor is not overloaded.
The pump is stopped at a too high temperature. When the motor
Overtemperature electronics have cooled down sufficiently, the motor will restart au- –
tomatically.
Overload Provides overload protection of the motor. Motor starter.
Sensors can be connected directly to the CU 300.
Sensor alarm External control unit.
The sensor signals are monitored.
25
Pump selection SQ, SQ-N, SQE, SQE-N
26
Pump selection SQ, SQ-N, SQE, SQE-N
Pump sizing
Important: The dry-running protection is effective only
within the recommended pump duty range, i.e. the bold
curves. See performance curves.
Example:
Required: Flow rate: 2.4 m3/h => nearest higher value in table is 2.5 m3/h.
Head: 68.3 m => nearest higher value in the table is 78 m.
Selected: Pump type: SQ 3-65 (as it offers the best pump efficiency for the required flow and head).
Required pump power input: 1.02 kW.
Full load current: I1/1 = 6.2 A at 230 V.
I1/1 = 7.2 A at 200 V.
Pipe connection: Rp 1¼.
Length of pump: 826 mm
27
Pump selection SQ, SQ-N, SQE, SQE-N
0.00 0
1 mm2/s (1 cSt). If the pump is used for liquids with
0.0 0.8 1.6 2.4 3.2 Q [m³/h]
a viscosity higher than that of water, this will reduce
the head and increase the power consumption.
0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]
• Q/H: The curves are inclusive of valve and inlet
losses at the actual speed.
• Power curve: P2 shows pump power input per
stage.
• Efficiency curve: Eta shows pump efficiency per
stage.
28
Pump selection SQ, SQ-N, SQE, SQE-N
29
Pump selection SQ, SQ-N, SQE, SQE-N
Qmax [m3/h]
pmin ppre pcut-in pcut-out
[m] 0.6 0.8 1 1.2 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 [m] [m] [m]
Pressure tank size [litres]
25 8 8 18 18 18 18 24 33 33 50 50 50 50 80 80 80 80 80 22.5 26 40
30 8 8 18 18 18 24 33 33 50 50 50 50 80 80 80 80 80 27 31 45
35 8 18 18 18 18 24 33 33 50 50 50 80 80 80 80 80 31.5 36 50
40 8 18 18 18 18 24 33 50 50 50 80 80 80 80 80 36 41 55
45 8 18 18 18 24 33 33 50 50 50 80 80 80 80 40.5 46 60
50 8 18 18 18 24 33 50 50 50 80 80 80 80 45 51 65
55 18 18 18 18 24 33 50 50 50 80 80 80 49.5 56 70
60 18 18 18 18 24 33 50 50 80 80 80 80 54 61 75
65 18 18 18 24 24 33 50 50 80 80 80 80 58.5 66 80
Note: The pressure tank sizes stated in the table are
minimum requirements.
The use of a tank one size bigger is recommended.
1 m head = 0.098 bar
Example:
pmin: 45 m, Qmax = 2.5 m3/h
The following values are found in the table:
Minimum size of pressure tank = 33 litres.
ppre = 40.5 m
pcut-in = 46 m
pcut-out = 60 m
30
31
Performance curves/ SQ 1, SQ 1-N, SQE 1, SQE 1-N
Technical data
SQ 1, SQ 1-N, SQE 1, SQE 1-N
p H
[kPa] [m]
2400 SQ 1
240 -155
SQ 1-N
220 SQE 1
-140
2000 SQE 1-N
200
ISO 9906 Annex A
-125
180
-110
1600
160
-95
140
100 -65
800 80
-50
60
-35
400 40
20
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [m³/h]
P2 Eta
[kW] [%]
0.20 40
0.15 P2 30
0.10 20
Eta
0.05 10
0.00 0
TM01 2692 4304
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Q [m³/h]
32
Technical data SQ 1, SQ 1-N, SQE 1, SQE 1-N
33
Performance curves SQ 2, SQ 2-N, SQE 2, SQE 2-N
p H
[kPa] [m]
SQ 2
1600
160 SQ 2-N
-115
SQE 2
140
SQE 2-N
ISO 9906 Annex A
-100
1200
120
-85
100
-70
800 80
-55
60
-35
400 40
20
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
P2 Eta
[kW] [%]
0.25 50
0.20 40
P2
0.15 30
Eta
0.10 20
0.05 10
0.00 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
34
Technical data SQ 2, SQ 2-N, SQE 2, SQE 2-N
35
Performance curves SQ 3, SQ 3-N, SQE 3, SQE 3-N
p H
[kPa] [m]
150
SQ 3
-105
1400 SQ 3-N
140
SQE 3
130 -95
SQE 3-N
1200 ISO 9906 Annex A
120
-80
110
1000
100
-65
90
800 80
-55
70
600 60
-40
50
400 40
-30
30
200 20
10
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]
P2 Eta
[kW] [%]
0.30 60
0.25 50
0.20 40
0.15 P2 30
Eta
0.10 20
0.05 10
0.00 0
TM01 2694 4304
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [m³/h]
36
Technical data SQ 3, SQ 3-N, SQE 3, SQE 3-N
37
Performance curves SQ 5, SQ 5-N, SQE 5, SQE 5-N
p H
[kPa] [m]
SQ 5
110
SQ 5-N
-70
1000
100 SQE 5
SQE 5-N
90 ISO 9906 Annex A
-60
800
80
70 -50
600 60
-35
50
400 40
-25
30
200 20 -15
10
0 0
0 1 2 3 4 5 6 7 Q [m³/h]
P2 Eta
[kW] [%]
0.35 70
0.30 60
0.25 50
P2
0.20 40
0.15 30
0.10 20
Eta
0.05 10
0.00 0
TM01 2695 4304
0 1 2 3 4 5 6 7 Q [m³/h]
38
Technical data SQ 5, SQ 5-N, SQE 5, SQE 5-N
39
Performance curves SQ 7, SQ 7-N, SQE 7, SQE 7-N
p H
[kPa] [m]
SQ 7
SQ 7-N
70
SQE 7
-40
SQE 7-N
600 ISO 9906 Annex A
60
50
400 -30
40
30
200 20 -15
10
0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
P2 Eta
[kW] [%]
0.48 60
0.40 50
0.32 P2 40
0.24 30
Eta
0.16 20
0.08 10
0.00 0
TM01 2696 4304
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
40
Technical data SQ 7, SQ 7-N, SQE 7, SQE 7-N
41
Technical data SQ, SQ-N, SQE, SQE-N
42
Technical data SQ, SQ-N, SQE, SQE-N
220
43
Technical data SQ, SQ-N, SQE, SQE-N
Wiring diagrams
Mains connection of pump via pressure
switch
The pressure switch must be rated to the max. amps of
the specific pump size.
N L
TXD
RI
B
Y
A
+24VDC
+24VDC
+24VDC
POWER PUMP
COM
COM
GND
GND
GND
Auxiliary relay:
NO
NO
NC
NC
IN
IN
IN
PE
PE ALARM AUX DIG SENSOR SENSOR RS RS
RELAY RELAY IN 1 2 485 232 Potential-free changeover contact
Maximum contact load: Safety extra-low voltage to be used only.
Max. current 1A
Minimum contact load: DC 5 V, 10 mA
Digital input:
External potential-free contact
Logic "0": Uin > 3.2 V
1 2 3 4 Logic "1": Uin< 0.9 V
POWER PUMP
PE Sensor 1:
PE
Voltage signal: DC 0 - 10 V/2 - 10 V, Ri = 11 kΩ.
Tolerance: ± 3% at maximum voltage signal.
Screened cable recommended, maximum length of cable: 500 m.
Current signal: DC 0 - 20 mA/4 - 20 mA, Ri = 500 Ω.
Tolerance: ± 3% at maximum current signal.
Screened cable recommended, maximum length of cable: 500 m.
Sensor 2:
Potentiometer: DC 0 - 24 V, 10 kΩ (via internal voltage supply).
Screened cable recommended, maximum length of cable: 100 m.
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
+24VDC
+24VDC
COM
COM
GND
GND
GND
NO
NC
NC
IN
IN
IN
44
Technical data SQ, SQ-N, SQE, SQE-N
MADE IN POLAND
relpol
4080
POWER PUMP Screened cable recommended, maximum length of cable: 500 m.
DC 24 V
AC 250 V 16 A
2
5
4
relpol
8
7
1 RM85-3021-25-1024
DC 24 V
Max. 0.5 A
SENSOR 8 5
RELAY
7 4
9 8
1 2
PE
MADE IN POLAND
4080
Tolerance: ± 3% at maximum current signal.
Screened cable recommended, maximum length of cable: 500 m.
Operating relay:
The operating relay is a normally open (NO) contact, the relay is activated when
the pump is running.
• Max 0,5 A
• Maximum voltage 230 VAC
RM85-3021-25-1024
MADE IN POLAND
relpol
4080
DC 24 V
AC 250 V 16 A
2
5
4
8
7
+24V IN GND
5 6 7
5 6 7
SENSOR
45
Accessories SQ, SQ-N, SQE, SQE-N
CU 301
Product Product number
CU 301 96436753 (Europe)
CU 300
Product Product number
CU 300 96422775 (English)
Language specific CU 300 versions available on request.
46
Accessories SQ, SQ-N, SQE, SQE-N
3-core cable incl. earth conductor 3G 2.5 mm2 (round) 11.5 - 14.5 ID7947
KTW approved. When ordering 3G 4.0 mm2 (round) 13.0 - 16.0 ID7948
please state length [m] 3G 6.0 mm2 (round) 14.5 - 20.0 RM4098
3G x 1.5 mm2 (flat) 6.5 - 13.2 RM3952
t
getrank
en
The joint is ready for use after a few minutes and requires no
ngstuch
Reinigu Trichlorethan beim Einatm
ch
mit 1,1,1 chadeli
dheltss
(gesun lucken)
oder Versch
neret
impræg
erviet
Renses trichlorethan
eller
med 1,1,1 indånding
ved
207-3
EPPA
Cable clips
Nominal diameter
Description Product no.
[mm]
For fastening of cable and straining wire to the riser pipe.
length = 7.5 m
The clips should be fitted every 3 metres 00115016
16 buttons
One set for approx. 45 m riser pipe.
TM00 4179 1994
Pressure tank
Duty range
D
Precharge pressure: 1½ bar
Max. Operating pressure: 10 bar
Max. liquid temperature: +99°C
Flange material: Stainless steel
Description Connection D [mm] H [mm] Weight [kg] Product no.
8 litres G¾ 202 303 2.3 96528335
18 litres G¾ 279 367 4.6 96526322
24 litres G1 289 447 5.1 96528339
H
47
Accessories SQ, SQ-N, SQE, SQE-N
Pressure gauge
Measuring range Connection G Diameter [mm] Product no.
0 - 6 bar ¼ 50 ID3266
0 - 10 bar ¼ 63 ID8048
Straining wire
Description Diameter Product no.
Stainless steel DIN W.-Nr. 1.4401.
Retains the submersible pump. 2 mm 00ID8957
When ordering please state length [m].
TM00 7897 2296
Wire clamp
Description Version Product no.
Stainless steel DIN W.-Nr. 1.4401. Two clamps per loop 00ID8960
TM00 7898 2296
Flow sleeve
650 100
88
ø90
210 50 550 50
250
48
Accessories SQ, SQ-N, SQE, SQE-N
Presscontrol
Description Version Product no.
Presscontrol PC 15 for automatic SQ-operation.
1.5 bar, without plug.
1 x 220-240 V 465322
Max. pressure: 10 bar.
See page 10 for further information.
Printer
Description Product no.
Printer for R100, infrared communication,
620480
Type: Hewlett Packard, HP 82240B.
Paper roll. 620481
TM00 8368 2796
Potentiometer, SPP 1
Description Version Product no.
External potentiometer with cabinet for wall mounting.
Grundfos potentiometer, SPP 1.
Screened cables, 4-wire cable. 625468
Enclosure class: IP 55
Max. length of cable: 100 m.
TM00 2604 4793 - TM01 3291 3798
49
Accessories SQ, SQ-N, SQE, SQE-N
Sensors
Sensors Supplier Type Measuring Range Product no.
Level sensor, incl. 30 m cable JUMO 4390-242 0 - 2.5 bar 96037489
Level sensor, incl. 65 m cable JUMO 4390-242 0 - 6 bar 96037490
Level sensor, incl. 105 m cable JUMO 4390-242 0 - 10 bar 96037491
Pressure switch Condor mdr 21/6 1 - 6 bar ID6462
Flow switch unit (SQE 1, SQE 2, SQE 3) Grundfos mdr 21/6 1" 0 - 5 m3/h 96037332
Flow switch unit (SQE 5, SQE 7) Grundfos FS 200 5 - 7 m3/h 96037559
Flow meter (pulsating) 1 l/pulse Bdr. Dahl QN 2.5 0 - 5 m3/h 96037492
Flow meter (pulsating) 2.5 l/pulse Bdr. Dahl QN 6 0 - 12 m3/h 96037583
Flow meter (pulsating 5 l/pulse Bdr. Dahl QN 10 0 - 20 m3/h 96037584
0 - 4 bar 405160
Pressure sensor kit for CU 300 incl. 2 m cable Danfoss MBS 3000
0 - 6 bar 405161
Pressure sensor kit for CU 301 incl. 2 m cable Grundfos Grundfos type 0 - 6 bar 96437851
50
Order data SQ, SQ-N, SQE, SQE-N
SQ/SQ-N/SQE
Motor
Pump type Output power Product number
Type motor (P2) [kW]
SQ 1 - 35 MS 3 0.70 96510178
SQ 1 - 35 N MS 3 - NE 0.70 96160370
SQE 1 - 35 MSE 3 0.70 96510071
SQE 1 - 35 N MSE 3 - NE 0.70 96160436
SQ 1 - 50 MS 3 0.70 96510179
SQ 1 - 50 N MS 3 - NE 0.70 96160371
SQE 1 - 50 MSE 3 0.70 96510141
SQE 1 - 50 N MSE 3 - NE 0.70 96160437
SQ 1 - 65 MS 3 0.70 96510190
SQ 1 - 65 N MS 3 - NE 0.70 96160372
SQE 1 - 65 MSE 3 0.70 96510142
SQE 1 - 65 N MSE 3 - NE 0.70 96160438
SQ 1 - 80 MS 3 1.15 96510191
SQ 1 - 80 N MS 3 - NE 1.15 96160373
SQE 1 - 80 MSE 3 1.15 96510143
SQE 1 - 80 N MSE 3 - NE 1.15 96160439
SQ 1 - 95 MS 3 1.15 96510192
SQ 1 - 95 N MS 3 - NE 1.15 96160374
SQE 1 - 95 MSE 3 1.15 96510144
SQE 1 - 95 N MSE 3 - NE 1.15 96160440
SQ 1 - 110 MS 3 1.15 96510193
SQ 1 - 110 N MS 3 - NE 1.15 96160375
SQE 1 - 110 MSE 3 1.15 96510145
SQE 1 - 110 N MSE 3 - NE 1.15 96160441
SQ 1 - 125 MS 3 1.68 96510194
SQ 1 - 125 N MS 3 - NE 1.68 96160376
SQE 1 - 125 MSE 3 1.68 96510146
SQE 1 - 125 N MSE 3 - NE 1.68 96160442
SQ 1 - 140 MS 3 1.68 96510195
SQ 1 - 140 N MS 3 - NE 1.68 96160377
SQE 1 - 140 MSE 3 1.68 96510147
SQE 1 - 140 N MSE 3 - NE 1.68 96160443
SQ 1 - 155 MS 3 1.85 96510196
SQ 1 - 155 N MS 3 - NE 1.85 96160378
SQE 1 - 155 MSE 3 1.85 96510148
SQE 1 - 155 N MSE 3 - NE 1.85 96160444
51
Order data SQ, SQ-N, SQE, SQE-N
Complete unit: SQ 2, SQ 2-N, SQE 2, SQE 2-N Complete unit: SQ 5, SQ 5-N, SQE 5, SQE 5-N
Motor Motor
Pump type Output power Product number Pump type Output power Product number
Type motor (P 2) [kW] Type motor (P2) [kW]
SQ 2 - 35 MS 3 0.70 96510198 SQ 5 - 15 MS 3 0.70 96510211
SQ 2 - 35 N MS 3 - NE 0.70 96160379 SQ 5 - 15 N MS 3 - NE 0.70 96160393
SQE 2 - 35 MSE 3 0.70 96510150 SQE 5 - 15 MSE 3 0.70 96510163
SQE 2 - 35 N MSE 3 - 0.70 96160445 SQE 5 - 15 N MSE 3 - NE 0.70 96160459
SQ 2 - 55 MS 3 0.70 96510199
SQ 5 - 25 MS 3 0.70 96510212
SQ 2 - 55 N MS 3 - NE 0.70 96160380
SQ 5 - 25 N MS 3 - NE 0.70 96160394
SQE 2 - 55 MSE 3 0.70 96510151
SQE 2 - 55 N MSE 3 - 0.70 96160446 SQE 5 - 25 MSE 3 0.70 96510164
SQ 2 - 70 MS 3 1.15 96510200 SQE 5 - 25 N MSE 3 - NE 0.70 96160460
SQ 2- 70 N MS 3 - NE 1.15 96160381 SQ 5 - 35 MS 3 1.15 96510213
SQE 2 - 70 MSE 3 1.15 96510152 SQ 5 - 35 N MS 3 - NE 1.15 96160395
SQE 2 - 70 N MSE 3 - 1.15 96160447 SQE 5 - 35 MSE 3 1.15 96510165
SQ 2 - 85 MS 3 1.15 96510201 SQE 5 - 35 N MSE 3 - NE 1.15 96160461
SQ 2 - 85 N MS 3 - NE 1.15 96160382 SQ 5 - 50 MS 3 168 96510214
SQE 2 - 85 MSE 3 1.15 96510153
SQ 5 - 50 N MS 3 - NE 1.68 96160396
SQE 2 - 85 N MSE 3 - 1.15 96160448
SQE 5 - 50 MSE 3 1.68 96510166
SQ 2 - 100 MS 3 1.68 96510202
SQE 5 - 50 N MSE 3 - NE 1.68 96160462
SQ 2 - 100 N MS 3 - NE 1.68 96160383
SQE 2 - 100 MSE 3 1.68 96510154 SQ 5 - 60 MS 3 1.68 96510215
SQE 2 - 100 N MSE 3 - 1.68 96160449 SQ 5 - 60 N MS 3 - NE 1.68 96160397
SQ 2 - 115 MS 3 1.85 96510203 SQE 5 - 60 MSE 3 1.68 96510167
SQ 2 - 115 N MS 3 - NE 1.85 96160384 SQE 5 - 60 N MSE 3 - NE 1.68 96160463
SQE 2 - 115 MSE 3 1.85 96510155 SQ 5 - 70 MS 3 1.85 96510217
SQE 2 - 115 N MSE 3 - 1.85 96160450 SQ 5 - 70 N MS 3 - NE 1.85 96160398
Complete unit: SQ 3, SQ 3-N, SQE 3, SQE 3-N SQE 5 - 70 MSE 3 1.85 96510168
SQE 5 - 70 N MSE 3 - NE 1.85 96160464
Motor
Pump type Output power Product number Complete unit: SQ 7, SQ 7-N, SQE 7, SQE 7-N
Type motor (P 2) [kW]
Motor
SQ 3 - 30 MS 3 0.70 96510204
Pump type Output power Product number
SQ 3 - 30 N MS 3 - NE 0.70 96160386 Type motor (P2) [kW]
SQE 3 - 30 MSE 3 0.70 96510156
SQ 7 - 15 MS 3 0.70 96510218
SQE 3 - 30 N MSE 3 - 0.70 96160452
SQ 7 - 15 N MS 3 - NE 0.70 96160399
SQ 3 - 40 MS 3 0.70 96510205
SQE 7 - 15 MSE 3 0.70 96510169
SQ 3 - 40 N MS 3 - NE 0.70 96160387
SQE 7 - 15 N MSE 3 - NE 0.70 96160465
SQE 3 - 40 MSE 3 0.70 96510157
SQ 7 - 30 MS 3 1.15 96510219
SQE 3 - 40 N MSE 3 - 0.70 96160453
SQ 7 - 30 N MS 3 - NE 1.15 96160400
SQ 3 - 55 MS 3 1.15 96510206
SQE 7 - 30 MSE 3 1.15 96510170
SQ 3 - 55 N MS 3 - NE 1.15 96160388
SQE 7 - 30 N MSE 3 - NE 1.15 96160466
SQE 3 - 55 MSE 3 1.15 96510158
SQ 7 - 40 MS 3 1.68 96510220
SQE 3 - 55 N MSE 3 - 1.15 96160454
SQ 7 - 40 N MS 3 - NE 1.68 96160401
SQ 3 - 65 MS 3 1.15 96510207
SQE 7 - 40 MSE 3 1.68 96510171
SQ 3 - 65 N MS 3 - NE 1.15 96160389
SQE 7 - 40 N MSE 3 - NE 1.68 96160467
SQE 3 - 65 MSE 3 1.15 96510159
SQE 3 - 65 N MSE 3 - 1.15 96160455
SQ 3 - 80 MS 3 1.68 96510208
SQ 3 - 80 N MS 3 - NE 1.68 96160390
SQE 3 - 80 MSE 3 1.68 96510160
SQE 3 - 80 N MSE 3 - 1.68 96160456
SQ 3 - 95 MS 3 1.68 96510209
SQ 3 - 95 N MS 3 - NE 1.68 96160391
SQE 3 - 95 MSE 3 1.68 96510161
SQE 3 - 95 N MSE 3 - 1.68 96160457
SQ 3 - 105 MS 3 1.85 96510210
SQ 3 - 105 N MS 3 - NE 1.85 96160392
SQE 3 - 105 MSE 3 1.85 96510162
SQE 3 - 105 N MSE 3 - 1.85 96160458
52
Order data SQ, SQ-N, SQE, SQE-N
Submersible drop cables A product number from the table below covers the fol-
lowing:
The submersible drop cables are approved for use in
drinking water (KTW approved). The material of the • One cable length with motor plug, packed
submersible drop cable is EPR. • 6 screws (M4) for fitting of plug
The table below shows the maximum length of the sub- • 3 screws (M3 x 6) for fitting of cable guard to suction
mersible drop cable for the different sizes of cross-sec- strainer.
tion of the leads according to a 4% voltage drop IEC 3-
64, HD-384 series or regulations set by the local Cross-section of leads
Length 2
authorities. If the pump operates at a higher voltage [m] 1.5 mm 2.5 mm 2 4 mm2 6 mm2
Flat Round Round Round
drop the pump performance will be reduced. The pump
1.5 96160869
will be cut out if voltage falls below 150 V.
5 96160870
Max. cable lengths: 10 96160871
15 96160872
Output power Max. length [m] 20 96160873
I1/1
motor
(P2) [kW] [A] 1.5 mm 2 2.5 mm2 4 mm2 6 mm2 30 96160874
40 96160875 96160583
0.7 5.2 69 115 185 277
50 96160876 96160584
1.15 8.4 43 71 114 171
60 96160877 96160585
1.68 11.2 32 54 86 129
70 96160878 96160586
1.85 12.0 30 50 80 120
80 96160879 96160587
The table values are calculated on the basis of the for-
90 96160880 96160588 96160590 96160592
mula:
100 96160881 96160589 96160591 96160593
Max. cable length of a single-phase submersible pump:
For cables with the cross-sections of leads, 2.5, 4 and
6 mm2, the cable consists of 1.5 m flat motor cable fol-
U × ΔU
L = --------------------------------------------------------- [ m ] lowed by a round submersible drop cable.
ρ
I × 2 × 100 × ⎛ PF × ---⎞
⎝ q⎠
where
L = Max. length of cable [m]
U = Rated voltage [V]
ΔU = Voltage drop [%]
I = Rated current of the motor [A]
ρ = Specific resistance: 0.02 [Ω mm2/m]
PF = 1
q = Cross-section of submersible drop cable [mm2]
Example:
Voltage supply: 230V
Voltage drop: 4%
Current of the motor: 11.1 [A]
q = 1.5 mm2 cable.
230 × 4
L = ----------------------------------------------------------------- [ m ]
0.02
11.1 × 2 × 100 × 1 × -----------
1.5
L = 32 m
53
Order data SQ, SQ-N, SQE, SQE-N
SQ packages
Packages of SQ and SQE pumps including selected
lengths of submersible drop cable are listed below.
The length of the cable in below table are calculated
according to the actual motor load of each specific
pump size.
Cable length
Pump type (3 x 1.5 mm2) Product number
[m]
SQ 1 - 65 30 96524421
SQ 1 - 80 30 96524428
SQ 1 - 80 50 96524429
SQ 1 - 140 70 96524442 *
SQ 2 - 35 15 96524423
SQ 2 - 55 10 96524430
SQ 2 - 55 15 96524431
SQ 2 - 55 30 96524432
SQ 2 - 55 60 96524433
SQ 2 - 70 30 96524434
SQ 2 - 70 60 96524436
SQ 2 - 70 80 96524435 *
SQ 2 - 85 40 96524443
SQ 2 - 85 80 96524444 *
SQ 3 - 30 30 96618723
SQ 3 - 40 15 96524426
SQ 3 - 40 30 96524427
SQ 3 - 40 30 96160577 ***
SQ 3 - 55 15 96524437
SQ 3 - 55 30 96524438
SQ 3 - 65 30 96524439
SQ 3 - 65 40 96524440
SQ 3 - 80 30 96524445
SQ 3 - 80 50 96524446
SQ 3 - 95 70 96524447 *
SQ 3 - 105 80 96524448 **
SQ 5 - 35 15 96524441
SQ 5 - 50 15 96524449
SQ 5 - 50 30 96524450
SQ 5 - 60 30 96524451
SQ 5 - 70 30 96524452
SQ 7 - 40 15 96524453
* 3 x 2.5 mm2
** 3 x 4 mm2
*** Fitted with schuko plug.