Вы находитесь на странице: 1из 8

Data Sheet

Airmux-200
Wireless Broadband Multiplexer

• Cost-effective multi point-to-point encrypted wireless broadband multiplexer

Point-to-point and • Transmission range of up to 80 km (50 miles)


• 2.3 to 2.7 GHz and 4.9 to 6 GHz transmission bands
multipoint-to-point • Air data rate of up to 48 Mbps

radio solution for • High reliability and availability based on robust air interface protocol and 1+1
link redundancy
combined TDM and
Airmux-200 is a carrier-class, 48-Mbps Airmux-200 provides high performance
Ethernet traffic over capacity, cost effective and reliability. The interface ensures low
multipoint-to-point broadband wireless BER, as well as low latency, and full
license-free transmission system. It combines legacy compliance with E1/T1 interface jitter and
TDM and Ethernet services for wander requirements.
frequencies transmission over 2.3 to 2.7 GHz and Transmission range of up to 80 km
4.9 to 6 GHz bands, and is suitable for (50 miles) is available with an external
deployment in FCC-regulated countries. antenna.

The Access Company


Airmux-200
Wireless Broadband Multiplexer

In addition to Airmux-200, the following Two AC power supply options are available HUB SITE SYNCHRONIZATION
models are also available: for IDU-E: a single fixed power supply or Hub Site Synchronization (HSS) ensures
Airmux-200L – a low-price POE (Power two modular power supplies. All IDU simultaneous (multi point-to-point
over Ethernet) link for Ethernet services products include wide-range DC (-20 to deployment) data transmission for all
only that enables improved position -60 VDC) and AC (by AC converter) power collocated radios by eliminating the
versus low-end competitors. The supplies. interference that normally occurs when
supported frequencies are 2.4 FCC, 2.4 different ODUs transmit and receive from
High Power, and 5.8 FCC. Throughput is ADDITIONAL AIRMUX PRODUCTS the same site (see Figure 2).
limited to 2 MBps full-duplex with a IDU-R (Redundancy) – an IDU that HSS, which supports up to 16 collocated
maximum range of 20 km (12 miles). provides E1/T1 backup for a leased line to units (Airmux-200 and Airmux-400),
Airmux-200LC – an Airmux-200L with maintain continuous operation of the link. enables a complex radio environment of
hardware-ready collocation capabilities. Upon failure of the primary connection, mixed services (TDM or Ethernet) and
It enables Airmux-200L collocations at a IDU-R switches automatically to the channel bandwidth frequencies (5, 10, or
central site using burst synchronization backup link. The air interface can be 20 MHz).
pulses to reduce mutual interference. defined as the primary or backup link (see
The collocation feature requires ordering
Figure 3). IDU-R operates with all ODUs.
Airmux-200VS –a version is suitable for the HSS unit as well as its synchronization
video surveillance applications with ODU-HE (High End) – an enhanced ODU cables.
asymmetric Ethernet throughput of that features Hub Site Synchronization
ODU-High End (ODU-HE), All Indoor (AIND)
2/5 Mbps, at a distance of up to 20 km (HSS), transmits higher power for some
and Airmux-200L products support HSS.
(12.4 miles). frequencies and operates with IDU and
POE devices.
SECURITY
PHYSICAL CONFIGURATIONS POE-8 (Power over Ethernet) – an indoor
Data transmitted over the air interface is
Airmux multiplexers consist of an outdoor unit that feeds up to eight ODUs from a
encrypted using Advanced Encryption
unit (ODU) and an indoor unit (IDU or single unit, instead of using eight separate
System (AES) with a 128-bit encryption
IDU-Extended). POE devices. POE-8 uses AC as well as DC
key.
(-20 to -60 VDC) power.
The outdoor unit is suitable for mast or
wall installation. Mounting brackets are OPoE (Outdoor Power over Ethernet) – a 1+1 LINK REDUNDANCY
supplied with the unit. hardened product for outdoor installation.
The Monitored Hot Standby (MHS) 1+1
ODU-HE (high-end) operates with AIND (All Indoor) – a unit that integrates link redundancy protects the wireless
synchronized, collocated units and the ODU and the IDU-E into a single 19" transmission in case of equipment failure
supplies a higher output power of up to IDU-E box. or air interface loss. Link switchover is
23 dBm. performed in less than 50 msec.

Table 1. Radio Regulatory Compliance and Maximum Transmit Power

USA and Canada Europe (ETSI)


Frequency Regulation Max. Tx Power Regulation Max. Tx Power
[GHz] [dBm] [dBm]
5.740–5.940 47CFR Part 15 Subpart C, RSS-210 16/23 N/A N/A

5.500–5.700 N/A N/A EN 300 216 V1.2.1, 8


EN 301 893 V1.4.1 EIRP ≤ 30
5.260–5.330 47CFR Part 15 Subpart E , RSS-210 8 N/A N/A
4.950–4.980 47CFR Part 15 Subpart B 25 (FCC) N/A N/A
2.500–2.690 47CFR Part 15 Subpart B 22 EN 300 386 V1.3.2 23
EN 301 489-4 V1.3.1
EN 301 489-1 V1.4.1
2.412–2.462 47CFR Part 15 Subpart C , RSS-210 27 (for FCC) N/A N/A
2.412–2.472 N/A N/A EN 300 328 -4
EIRP ≤ 20
Data Sheet

ADAPTIVE MODULATION SFP PORT Broadband Access


Airmux-200 adaptively changes the The MSA-compatible port accepts Airmux-200 provides broadband Ethernet
modulation according to air conditions, SFP-based E3/T3 devices for transmitting and leased line services, to Small and
targeting maximum rate while maintaining 34.368-Mbps (E3) or 44.736-Mbps (T3) Medium Enterprises (SME).
link stability. The rate drops temporarily data streams over its wireless link. Wireless ISP Backhaul
after encountering interference, then Wireless Internet Service Providers (WISP)
automatically returns to the highest MANAGEMENT
backhaul their Point of Presence (POP)
possible rate. Factory settings can be restored at any traffic to the network operation center.
time for each ODU. With Airmux-200, WISPs achieve higher
QUALITY OF SERVICE
Information on links and management can capacity, and can offer bundled
When the link quality is out of limits, be collected and analyzed via a single connectivity, with a range of up to 80 km
Airmux-200 automatically searches for a action. (50 miles).
clear channel within a pre-selected list of
frequencies. VLAN management allows the separation Remote Site Connectivity
of user traffic from NMS traffic. The user Airmux-200 is also offered to enterprises
5 MHZ AND 10 MHZ CHANNEL decides if such a separation is required. with multiple sites that require a
BANDWIDTH Both the headquarters and remote sites transparent connection of LAN and PBX
Airmux-200 offers additional channel are configured with VLAN management. systems across their various campuses.
bandwidth options to the 20 MHz channel External events trigger alarms via the Video Surveillance
bandwidth already supported. Narrow dry-contact alarm inputs. Airmux-200VS provides asymmetric
channel bandwidth improves immunity to Application software on multiple links can Ethernet traffic stream at 2/5 Mbps for
disturbances and enables deployment in be upgraded simultaneously without distances of up to 20 km (12.4 miles).
high-interference environments, with affecting the service. This can be used for face recognition and
enhanced channel allocation flexibility and license plate identification in real time.
improved sensitivity. APPLICATIONS

INCREASED FRAME SIZE Cellular Backhaul


Airmux-200 connects between cellular
Airmux-200 supports larger frames
base stations and controllers. This
(1536 bytes for IDU, 1800 bytes for POE)
solution meets the requirements of
to improve Ethernet traffic efficiency and
cellular backhaul applications by providing
reduce the overall overhead.
four E1/T1 interfaces and Ethernet traffic
SHORT TIME-TO-SERVICE for maintenance and control.

Because Airmux-200 operates in Hot-Spot Backhauling


license-exempt frequencies, it can be Airmux-200 provides a robust alternative
deployed in record time, eliminating the to the last mile connection between the
costs and delays involved in leasing lines WLAN access point and the data network,
or trenching fiber. compared with the often used expensive
E1/T1 leased lines.

Figure 1. Point-to-Point Application


Airmux-200
Wireless Broadband Multiplexer

LAN INTERFACE E1/T1 INTERFACE


Specifications
Number of Ports Number of Ports
RADIO
IDU: 1 IDU: 1 or 2
Frequency Bands (GHz) IDU-E: 2 IDU-E: 4
6.0 (5.805–6.020)
Type Framing
5.9 (5.740–5.940)
10/100BaseT, autonegotiation Unframed
5.8 (5.740–5.835)
5.4 (5.500–5.700) Framing/Coding Timing
5.3 (5.260–5.330) IEEE 802.3u Plesiochronous (independent
4.9 (4.950–4.980) Tx and Rx timing)
Bridging
2.4 (2.412–2.462)
Up to 2048 MAC addresses self-learning Line Code
2.3 (2.312–2.387)
E1: HDB3
2.3 BRS (2.500–2.690 BRS) Traffic Handling
MAC layer bridging, self-learning T1: B8ZS, AMI
Data Rate
Latency
Up to 48 Mbps, user-configurable Latency
3 msec (typical) 8 msec
Channel Bandwidth
Line Impedance
20 MHz Line Impedance
100Ω E1: 120Ω, balanced
Duplex Technique T1: 100Ω, balanced
TDD VLAN Support
Transparent Connector
Modulation RJ-45
OFDM - BPSK, QPSK, 16 QAM, 64 QAM Connector
RJ-45 Jitter and Wander
Transmit Power As per G.823, G.824
See Table 1

RF Dynamic Range
More than 50 dB

Figure 2. Airmux-200 and Airmux-400 Collocated at a Central Site (Multi Point-to-Point)


Data Sheet

SFP PORT GENERAL Physical


Type Diagnostics ODU (with integrated antenna):
Fast Ethernet Local and remote loopbacks Height: 305 mm (12.0 in)
Width: 305 mm (12.0 in)
For full details, see the SFP Transceivers IDU-to-ODU Connection Depth: 58 mm (2.3 in)
data sheet at www.rad.com Outdoor Cat.5e cable, 100m (328 ft) max. Weight 1.5 kg (3.3 lb)
Note: It is strongly recommended to order this length
IDU:
device with original RAD SFPs installed. This will
Grounding and Lightning Protection Height: 44 mm (1.7 in)
ensure that prior to shipping, RAD has performed
Individual grounding for each IDU/ODU Width: 237 mm (9.3 in)
comprehensive functional quality tests on the
entire assembled unit, including the SFP devices. Internal arrestors for lightning protection Depth: 165 mm (6.5 in)
RAD cannot guarantee full compliance to product Internal ESD protection circuits over Weight 0.5 kg (1.1 lb)
specifications for units using non-RAD SFPs. power/telecom lines
IDU-E:
For detailed specifications of the SFP transceivers,
Power Height: 44 mm (1.7 in)
see the SFP Transceivers data sheet.
DC: -48, 24 VDC Width: 430 mm (17.0 in)
AC: 100–240 VAC Depth: 290 mm (11.4 in)
MANAGEMENT
Power Consumption Weight: 1.5 kg (3.3 lb)
Network Management and Protocol
ODU with IDU: 10W max
SNMP-based, Telnet
ODU with IDU-E: 14W max
Management Interface
Indicators
10/100BaseT
PWR (green) – Power status
Connector IDU (green) – IDU status
RJ-45 ODU (green/red) – ODU-to-IDU link status
AIR I/F (green/red) – Air Interface status
Upgrade Capabilities
SERVICE (green/red) – E1/T1 signal status
Local and over-the-air software
download Environment
Outdoor unit and external antenna:
ANTENNA Enclosure: IP67 all-weather case
Temperature: -35° to 60°C (-31° to 140°F)
Characteristics
Indoor units:
See Table 2
Temperature: 0° to 50°C (32° to 122°F)
Humidity: Up to 90%, non-condensing

Table 2. Airmux-200 Antenna Options

Frequency Antenna Type Gain Typical Range Beam Dimensions Weight Connector
[GHz] [dBi] [km] [mi] [degrees] [mm] [in] [kg] [Ib]
5.9, 5.8, 5.4, Integrated Flat panel 22 40 25 9.0 305×305×58 12×12×2.3 0.5 1.1 NR
5.3 External Flat panel 28 80 50 4.5 600×600×51 23.6×23.6×2 5.0 11.0 N-type
5.8 External Dish 32.5 80 50 4.5 Diam. 900 Diam. 35.4 10 22 N-type
4.9 External Flat panel 21 24 15 9.0 305×305×58 12×12×2.3 0.5 1.1 N-type
External Dish 27 80 50 5 Diam. 600 Diam. 23.6 5.0 11.0 N-type
2.3, 2.4 Integrated Flat panel 17 40 25 20 305×305×58 12×12×2.3 0.5 1.1 NR
External Grid 24 80 50 7.5 600×997×380 23.5×39.2×15 2.0 4.4 N-type
Note: The range depends on the system configuration. For further information, contact the RAD partner nearest you or one of RAD's offices worldwide.
Airmux-200
Wireless Broadband Multiplexer

Ordering Airmux-200/ODU-HE/@/CMB Airmux-200L/?/%/INT/a


Outdoor unit, high-end, configurable via Low Ethernet traffic, outdoor unit, POE,
INDOOR UNIT
Combo Configuration tool and integrated antenna
Airmux-200/IDU/~/UTP/*
Note: Available with F58F only.
Indoor unit Airmux-200/ODU-HE/@/CMB/EXT
Outdoor unit, high-end, configurable via Airmux-200LC/?/%/EXT/a
Airmux-200/IDUE-4
Combo Configuration tool, external Collocated, low Ethernet traffic, outdoor
Extended indoor unit with redundant DC
antenna unit and POE
power supply, 4 TDM ports, 2 FE ports,
multiple clocks POWER OVER ETHERNET Airmux-200LC/?/%/INT/a
Airmux-200/=/~/POE Collocated, low Ethernet traffic, outdoor
Airmux-200/IDU-R/&/a
Outdoor unit with POE device with unit, POE, and integrated antenna
Indoor unit with TDM bypass
integrated antenna Note: Available with F58F only.
OUTDOOR UNIT
Airmux-200/+/~/EXT/POE Note: All Airmux-200 products support the narrow
Airmux-200/ODU/#/^
Outdoor unit with POE device for external channel bandwidth, in addition to 20 MHz, except
Outdoor unit
antenna for the following that support 20 MHz only:
Airmux-200/ODU-HE/!
Airmux-200/POE-8/a ƒ ODU with the frequencies 5.3E, 5.3F, 5.4E,
Outdoor unit, high-end
Indoor device feeding 8 ODUs via PoE 5.4E-HG, 5.4E-LG, 5.4IC, 5.8UK
Airmux-200/ODU-HE/!!/EXT ports with AC and DC
ƒ POE with frequencies 4.9FP, 5.3E, 5.4E, 5.4E-HG,
Outdoor unit, high-end, external antenna
Airmux-200/POE-AC/a 5.4E-LG
Note 1: A multi point-to-point application supports POE device with AC plug Airmux-200L and Airmux-200LC support 5 MHz
multiple collocated radio links at a central site. This
Airmux-200/POE-DC/>> channel bandwidth only.
site is based on high-end ODUs (ODU-HE) and on
synchronization hub(s) (HSSU). When running a Airmux-200/OPOE Legend
multi point-to-point site, the customer must order Outdoor POE device with AC ~ Power supply:
the appropriate ODU-HEs, HSSUs, and cables. 115 115 VAC power supply
COLLOCATION HUBS
Note 2: ODU do not interoperate with standalone 230 230 VAC power supply
Airmux/HSSU
POE devices. For POE configurations, a specific ODU ACOC AC open-ended
Hub site sync unit to connect 8 collocated
is required.
outdoor units and 2 additional HSSUs ACUK UK
Airmux-200VS/<</EXT
AIRMUX-200L/LC IDU-E only:
Outdoor unit for video surveillance
48 -48 VDC power supply
application, external antenna Airmux-200L/?/%/EXT/a
Low Ethernet traffic, outdoor unit, and 24 24 VDC power supply
Airmux-200VS/<</INT
POE Note: The power supply of the single power supply
Outdoor unit for video surveillance
option is not removable.
application, integrated antenna
For IDU, the default power supply is –20 to -60
VDC. AC power in the IDU is supplied by an AC/DC
adapter.

Figure 3. Automatic Radio Link Backup


Data Sheet

a AC plug: F54HP High-power F54 * IDU interface:


ACEU European F58F 5.740–5.835 GHz, FCC E1 E1 interface
ACUS US F58E 5.740–5.835 GHz, ETSI T1 T1 interface
ACUK UK Note: F23HP, F24HP, F24E-LG, F53E, 2E1 2 x E1 interfaces
ACOC Open-ended F54E-LG and F54E-HG are available with external 2T1 2 x T1 interfaces
antenna only.
>> Power supply: ETH Ethernet interface
48 -48 VDC power supply % Frequency band and regulation: only
F24F 2.412–2.462 GHz, FCC ^ EXT for outdoor unit with dedicated
24 24 VDC power supply
F24HP 2.4 GHz high-power connector for external antenna
? Net Ethernet throughput:
F58F 5.740–5.835 GHz FCC connection
2 2 Mbps
! Frequency band and regulation: Note: If EXT is not specified, Airmux-200/ODU
= Frequency band and regulation: is supplied with an integrated antenna.
F24F 2.412–2.462 GHz, FCC
F24F 2.412–2.462 GHz, FCC
F24HP High-power F24 & TDM interface:
F24HP High-power F24
F25BRS 2.500–2.690 GHz BRS FCC E1 E1 interface
F54E 5.500–5.700 GHz, ETSI
F49F 4.850–4980 GHz, FCC T1 T1 interface
F54HP High-power F54
F54E 5.500–5.700 GHz, ETSI
F58F 5.740–5.835 GHz FCC OPTIONAL ACCESSORIES
F54HP High-power F54
+ Frequency band and regulation: F58F 5.740–5.835 GHz FCC Airmux-ANT/$
F24E-LG 2.412–2.472 GHz, ETSI,
F58E 5.740–5.835 GHz, ETSI External antenna supplied with 1m (3.3 ft)
low-gain
F59HP High power 5.725–5.950 GHz cable
F24F 2.412–2.462 GHz, FCC
F60HP High power 5.805–6.020 GHz Legend
F24HP High-power F24
!! Frequency band and regulation: $ External antenna, where grid is a grid
F53E 5.180–5.320 GHz, ETSI
F24F 2.412–2.462 GHz, FCC antenna, fp is a flat panel antenna,
F53HP High-power F53 and dish is a dish antenna:
F24HP High-power F24
F54E-HG High-gain F54E 17/F2X/db/fp 17 dBi, 2.7–2.9 GHz
F25BRS 2.500–2.690 GHz BRS FCC
F54E-LG Low-gain F54E 18/F5X/db/fp 18 dBi, 5.x GHz
F27HP High-power F27
F54HP High-power F54 21/4.9/db/fp 21 dBi, 4.9 GHz
F49F 4.950–4.980 GHz, FCC
F58F 5.740–5.835 GHz, FCC 22/5.3/db/fp 22 dBi, 5.3 GHz
F54E-LG Low-gain F54E
@ Frequency band and regulation: 22/5.4/db/fp 22 dBi, 5.4 GHz
F54IC 5.500–5.700 GHz, Canada
F54IC F54 Canada 22/5.8/db/fp 22 dBi, 5.8 GHz
F54HP High-power F54
F54F F54 FCC 24/2.4/db/grid 24 dBi, 2.4 GHz
F58F 5.740–5.835 GHz FCC
F58IDA F58 WPC India 24/2.5/db/grid 24 dBi, 2.5 GHz
F58UK 5.740–5.835 GHz, UK
F58F F58 FCC 27/4.9/db/dish 27 dBi, 4.9 GHz
F58E 5.740–5.835 GHz, ETSI
# Frequency band and regulation: 28/5.3/db/fp 28 dBi, 5.3 GHz
F59HP High power 5.725–5.950 GHz
F23HP 2.312–2.387 GHz, high 28/5.4/db/fp 28 dBi, 5.4 GHz
F60HP High power 5.805–6.020 GHz
power 28/5.8/db/fp 28 dBi, 5.8 GHz
F24HP High-power F24 << Frequency band and regulation:
29/5.8/db/dish 29 dBi, 5.8 GHz
F24E-LG Low-gain F24E F24F 2.4 GHz FCC (default),
32/5.3/db/dish 32.5 dBi, 5.3 GHz
2.4 GHz universal
F24F 2.412–2.462 GHz, FCC 32/5.4/db/dish 32.5 dBi, 5.4 GHz
F54E 5.4 GHz ETSI (default),
F53E 5.180–5.320 GHz, ETSI 32/5.8/db/dish 32.5 dBi, 5.8 GHz
5.8 GHz ETSI
F53HP High-power F53
F58F 5.8Ghz FCC (default),
F54E 5.500–5.700 GHz, ETSI 4.9 GHz universal, 5.3 GHz
F54E-HG High-gain F54E universal, 5.4 GHz universal,
F54E-LG Low-gain F54E 5.8GHz WPC, 5.9GHz
F54IC F54 Canada universal
Data Sheet
Airmux-200
Wireless Broadband Multiplexer

product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
199-100-09/09 Specifications are subject to change without prior notice. © 2002–2009 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the
CBL-Airmux-UTP/@ CBL-HSS/@@ RM-33
Assembled cable for permanent Assembled cable for permanent Hardware kit for mounting one IDU in a
connection between indoor and outdoor connection to HSS 19-inch rack
units Legend
PS-AC/a
Legend @@ Cable length: Power adapter for IDU, 90–240 VAC to
@ Cable length: 5 5m (16.4 ft) cable 48 VDC
25 25m (82 ft) cable 15 15m (49.2 ft) cable
50 50m (164 ft) cable 50 50m (164 ft) cable PS-E-AC/a
75 75m (246 ft) cable Power adapter for IDU-E, 90–240 VAC to
100 100m (328 ft) cable
48 VDC
100 100m (328 ft) cable
MHS-kit Legend
Cable and patch panel assembly (8 × RJ-45 a AC plug:
Y-connections) for Monitored Hot Standby
ACEU European
configuration
ACUS US
ACUK UK
ACOC Open-ended

Table 3. Airmux Family Product Comparison

Features

Airmux-200 Airmux-400
(Ver. 1.900) (Ver. 2.3)
Net throughput, full duplex 18 Mbps 50 Mbps
Ethernet ports 2 × Fast Ethernet 2 × Fast Ethernet
TDM ports 1, 2, 4 4, 8, 16
Security AES 128 AES 128
Maximum range 80 km (50 miles) 120 km (75 miles)

International Headquarters North America Headquarters


24 Raoul Wallenberg Street 900 Corporate Drive
Tel Aviv 69719, Israel Mahwah, NJ 07430, USA
Tel. 972-3-6458181 Tel. 201-5291100
Fax 972-3-6498250, 6474436 Toll free 1-800-4447234
E-mail market@rad.com Fax 201-5295777
E-mail market@radusa.com

www.rad.com Order this publication by Catalog No. 803516


The Access Company