Вы находитесь на странице: 1из 14

THIN LAYER CHROMATOGRAPHY

Reference:
1. Schoffstall, Gaddis, Druelinger, Microscale and Miniscale Organic
Chemistry Laboratory Experiments, 2nd edition, McGraw Hill
2. Dickson, Kittredge, Sarquis, J.Chem.Ed, Vol81, No 7, PP 1023 – 1025,
July 2004

Theory
Chromatographic techniques are used extensively in organic chemistry
laboratories for routine analysis. Thin layer chromatography (TLC) can be used
to determine the purity of a compound, to analyze the composition of a mixture or
to follow the progress of a reaction. The components of a mixture are
differentiated by exposing to two competing phases, the stationary and the
mobile phases. In TLC, the stationary phase is a polar adsorbent such as silica
gel or alumina, which has been coated on a plastic plate. The mobile phase is an
organic solvent. The solvent moves up the plate by capillary action.

A coated and dried glass or plastic plate is called a thin-layer plate. The mixture
to be analyzed is dissolved in a suitable solvent and applied as spots near the
base of the plate. This process is known as spotting. Spotting is achieved by
repeated applications of the mixture from a capillary pipet. When the filled pipet
touches the plate, the liquid is delivered on to the plate by capillary action. The
plate is immersed in a development chamber (usually a beaker) that contains a
solvent or a mixture of solvents. The solvent in the development chamber is also
referred to as the eluent or eluting solvent. As the solvent rises up the plate by
capillary action, it carries the mixture with it. The components of the mixture are
separated on the stationary phase depending on their polarity. This process is
known as developing or running the TLC plate. Polar compounds are attracted to
the silica gel and are held more tightly compared to nonpolar compounds. A
separation results due to the difference in rates at which individual components

1
move on the plate. In general, nonpolar compounds move faster than polar
compounds on a TLC plate coated with silica gel.

When the plate has been developed, it is removed and allowed to dry. There will
a series of vertical spots on the plate. Each spot corresponds to a separate
component of the original mixture. If the components are colorless, the spots are
invisible. To see the spots, a visualization method is used. Ultraviolet lamp is a
common visualization method.
The distance traveled by each component is measured and this value is called
the retardation factor, designated as Rf value.

Rf value for a component is calculated using the following expression.

Rf = Distance traveled by the component


Distance traveled by the solvent

There is a Rf value associated with each developed spot on the TLC plate.

Figure 2: TLC
Figure 1: TLC plate in a
plate before beaker
development in a
beaker

2
solvent front

d solvent
d sample

origin Figure 3: TLC


plate after
Rf = dsample
dsolvent development

Procedure
In this guided inquiry lab, you will investigate properties such as hydrogen
bonding and polarity of various samples and solvents in context to TLC. You will
also apply your knowledge to a common industrial application such as separation
and identification of components in an analgesic medication.

Part 1: Effect of the length of TLC plate on Rf value


Obtain three TLC plates of varying lengths, a development chamber (400 mL
beaker and watch glass), a pencil and a ruler. Follow these instructions for all
three TLC plates. With a lead pencil (do not use a pen), draw a faint line 1 cm
from the bottom of a TLC plate. Mark a dot on this line. This dot will be the origin
for the substance (benzyl alcohol) that you will spot. With a Microcap capillary
tube, apply a tiny drop of benzyl alcohol (diluted by ethyl acetate in the ratio of
1:5) at the origin and air dry. Do not blow air. Place the TLC plate in a
developing chamber. Trickle down 60% ethyl acetate-40% hexanes (using a
pipet) along the sides of the beaker, making sure that the level of the solvent
is below the spotting line. The volume of the solvent used in this experiment
will vary with the size of the beaker, the distance of the spotting line from the
bottom plate and other dimensions of the TLC plate. Place a watch glass on the
beaker. You may also insert a piece of filter paper (as shown in Figure 2). When
the level of the solvent reaches ~ 0.5 cm from the top of the TLC plate, remove
the plate, quickly mark the solvent front with a pencil and let it air dry. Do not
shake the plate to dry it. Visualize the plate under a short wavelength UV lamp,

3
in a darkened hood. Lightly outline the spot with a pencil. Calculate Rf values for
benzyl alcohol on each TLC plate.

You may also choose to run all three TLC plates simultaneously (in separate
beakers). Make a sketch of the plates in your lab report.

Part 2: Effect of hydrogen bonding on Rf value


Obtain a TLC plate and spot the following compounds on the same plate. Make
sure the TLC plate is large enough to place all samples with good separation on
the spotting line. Use a new micropipette for each compound.

The compounds that you will use in this experiment are anisole, benzyl alcohol,
acetophenone, benzoic acid and phenyl acetate (dissolved in ethyl acetate).

Develop the TLC plate in a beaker with 60% ethyl acetate-40% hexanes. Circle
the spots on the TLC plate under UV light. Calculate the Rf value for each
sample.

Part 3: Effect of polarity of the solvent on Rf value


Obtain three TLC plates and spot benzyl alcohol on all the plates. Develop the
plates in three beakers labeled A, B and C. The beakers contain the solvent
mixtures listed below:

Beaker Solvent Mixtures


A 5% ethyl acetate – 95% hexanes
B 10% ethyl acetate – 90% hexanes
C 20% ethyl acetate – 80% hexanes

Visualize the spots under a UV lamp. Calculate the Rf value for benzyl alcohol on
each TLC plate.

Part 4: Analysis of analgesic tablets

4
Over the counter pain medications, such as Excedrin, Tylenol, and Advil,
commonly contains aspirin, ibuprofen, acetaminophen, and/or caffeine. TLC can
be used to determine whether an analgesic tablet contains one or more active
ingredients.
Your instructor will assign an analgesic tablet to your team. With a mortar and
pestle, pulverize the tablet. Add 25 mg of the powdered tablet to a vial and
dissolve in 0.5 mL methylene chloride (may also be labeled as dichloromethane).
Add 2 drops of ethanol (may also be labeled as ethyl alcohol) to help in the
dissolution of the tablet. Not all of the tablet will dissolve, because the analgesics
usually contain an insoluble binder. In addition, they may also contain buffering
agents or coatings that are insoluble in methylene chloride and ethanol. Similarly,
prepare solutions of aspirin, ibuprofen, acetaminophen, and caffeine in four
separate vials. Instead of 25 mg, use 1-2 mg for these compounds. These
solutions are the standards. Remember to label all vials clearly using a red
marker. Obtain a silica gel TLC plate (a sample plate is available to estimate the
dimensions), a development chamber (400 mL beaker and watch glass), a pencil
and a ruler.

With a lead pencil (do not use a pen), draw a faint line 1 cm from the bottom of
the TLC plate. Mark five dots on this line. These will be the origins for the
substances that you will spot. You will spot solutions of the analgesic tablet and
the standards on these dots. With a Microcap capillary tube, apply a tiny drop of
each solution at the origin and air dry. Do not blow air. Place the TLC plate in
the developing chamber. Trickle down ethyl acetate (using a pipet) along the
sides of the beaker, making sure that the level of the solvent is below the spotting
line. The volume of the solvent used will vary with the size of the beaker, the
distance of the spotting line from the bottom plate and other dimensions of the
TLC plate. Place the watch glass on the beaker. When the level of the solvent
reaches ~ 0.5 cm from the top of the plate, remove the plate, quickly mark the
solvent front with a pencil and let it air dry. Do not shake the plate to dry it.
Visualize the plate under a short wavelength UV lamp, in a darkened hood.

5
Lightly outline all the spots with a pencil. Calculate Rf values of the assigned
analgesic, and of caffeine, ibuprofen, aspirin, and acetaminophen. List the active
ingredients in the assigned analgesic tablet. Make a sketch of the plate in your
lab report. Make conclusions about the contents of each tablet.

6
THIN LAYER CHROMATOGRAPHY

YOUR NAME __________________

Questions

1. List any 2 factors that affect Rf values in TLC.

2. Explain how to prepare sample solutions.

3. Describe the principle that governs the TLC process.

4. When should a mixed solvent system be used for TLC?

5. What tool would you use to analyze the separated components in a


TLC process?

7
6. What would happen if
a) You had too much solvent in the developing chamber that it
covered the application spot.

b) You spotted a very concentrated solution of the analgesic.

c) You spotted a very dilute solution of the analgesic.

d) You placed the TLC plate slanted in the developing chamber.

e) You used a pen instead of a pencil to mark the origin spots.

7. What is meant by the term ‘green chromatography’? What advantages


does this green method have over traditional types of
chromatography?

8
8. Excipients were traditionally assumed to be inert. However, new
results show that they interact with the drug, affecting its dissolution,
absorption and bioavailability. Explain the role of excipients in drug
action.

9
Results and Conclusion

Part 1: Effect of the length of TLC plate on Rf value


Make a sketch of the three TLC plates. Label the plates. DO NOT TURN IN THE
ORIGINAL PLATE. DISCARD THEM AS INSTRUCTED.

Make conclusions about the effect of the length of TLC plates on Rf values.

10
Part 2: Effect of hydrogen bonding on Rf value
Calculate the Rf value for each sample.
Name of the Rf Value
compound
anisole
benzyl alcohol
acetophenone
benzoic acid
phenyl acetate

Based on the Rf values, classify the compounds in groups (if possible). Identify
the least and the most polar compound.

11
Part 3: Effect of polarity of the solvent on Rf value
Calculate the Rf value for benzyl alcohol on each TLC plate.

Beaker Solvent Mixtures Rf


A 5% ethyl acetate – 95% hexanes
B 10% ethyl acetate – 90% hexanes
C 20% ethyl acetate – 80% hexanes

From your data, arrange the solvent mixtures in the order of increasing polarity
(least to most).

12
Part 4: Analysis of analgesic tablets

Sketch the developed TLC plate to the right. →

Name of the Analgesic

Rf Value of the Analgesic


Rf Values of Active Ingredients Aspirin

Ibuprofen

Acetaminophe
n
Caffeine

Name of the Analgesic

Rf Value of the Analgesic


Rf Values of Active Ingredients Aspirin

Ibuprofen

Acetaminophe
n
Caffeine

13
Name of the Analgesic

Rf Value of the Analgesic


Rf Values of Active Ingredients Aspirin

Ibuprofen

Acetaminophe
n
Caffeine

Name of the Analgesic

Rf Value of the Analgesic


Rf Values of Active Ingredients Aspirin

Ibuprofen

Acetaminophe
n
caffeine

14

Вам также может понравиться