Issue Date: 2010-09-21 Page 1 of 37 Report Reference # E176413-A31-CB-3

Test Report issued under


the responsibility of:

Underwriters Laboratories Inc.

TEST REPORT
IEC/EN 60065
Audio, video and similar electronic apparatus:
Safety Requirements
Report Reference No .................. : E176413-A31-CB-3
Date of issue ................................. : 2010-09-21
Total number of pages .................. : 37

CB Testing Laboratory ............... : Underwriters Laboratories Inc.


Address ......................................... : 1285 Walt Whitman Road, Melville, NY, 11747, USA
Applicant's name ........................ : BOSE CORP
THE MOUNTAIN
Address ......................................... : FRAMINGHAM MA 01701
Test specification:
Standard ....................................... : IEC 60065:2001 + Amd 1:2005 / EN 60065:2002
Test procedure .............................. : CB Scheme
Non-standard test method ............ : N/A
Test Report Form No. ................. : IECEN 60065G
Test Report Form originator .......... : ASTABEAB
Master TRF ................................... : 2006-03
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is
acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

If this test Report is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.

This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 2 of 37 Report Reference # E176413-A31-CB-3

Test item description .................. : Powered Speaker System


Trade Mark .................................... :

Manufacturer ................................. : BOSE CORP


THE MOUNTAIN
FRAMINGHAM MA 01701
Model/Type reference ................... : PS3-2-1
PS3-2-1 II
PS3-2-1 III
CineMate digital home theater speaker system
CineMate series II digital home theater system
CineMate GS series II digital home theater system
Rating ............................................ : PS3-2-1: 100Vac 50/60Hz, 120Vac 60Hz, 220-240Vac 50/60Hz

PS3-2-1 II: 100Vac 50/60Hz, 120Vac 60Hz, 220-240Vac 50/60Hz,


115/230Vac 50/60Hz

PS3-2-1 III: 100Vac 50/60Hz, 120Vac 50/60Hz, 220-240Vac


50/60Hz, 115/230Vac 50/60Hz

CineMate: 120Vac 60Hz, 220-240VAC 50/60Hz,115/230V 50/60Hz

CineMate series II digital home theater system, CineMate GS series


II digital home theater system: 100-240Vac, 50/60 Hz

All models: 300W max.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 3 of 37 Report Reference # E176413-A31-CB-3

Testing procedure and testing location:


[x] CB Testing Laboratory
Testing location / address.............. : Underwriters Laboratories Inc. 1285 Walt Whitman Road,
Melville, NY, 11747, USA
[ ] Associated CB Test Laboratory
Testing location / address.............. :
Tested by (name + signature) ....... : Wojciech Poleszak

Approved by (+ signature) ............. : Eric A. Bull

[ ] Testing Procedure: TMP


Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Testing location / address.............. :
[ ] Testing Procedure: WMT
Tested by (name + signature) ....... :
Witnessed by (+ signature)............ :
Approved by (+ signature) ............. :
Testing location / address.............. :
[ ] Testing Procedure: SMT
Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Supervised by (+ signature) .......... :
Testing location / address.............. :
[ ] Testing Procedure: RMT
Tested by (name + signature) ....... :
Approved by (+ signature) ............. :
Supervised by (+ signature) .......... :
Testing location / address.............. :

Summary of Testing:
All Applicable tests according to the referenced standard(s) have been carried out
Summary of Compliance with National Differences:
AR, AT, AU, BE, CA, CH, CN, CZ, DE, DK, EU, FI, FR, GB, GR, HU, IT, JP, KR, MY, NL, NO, NZ,
PL, PT, SE, SG, SI, SK, UA, US

Copy of Marking Plate - Refer to Enclosure titled Marking Plate for copy.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 4 of 37 Report Reference # E176413-A31-CB-3

Test item particulars :


Classification of installation and use ....................: Household, Tabletop
Supply connection ................................................: Appliance inlet
Possible test case verdicts:
- test case does not apply to the test object ........: N/A
- test object does meet the requirement ..............: P(Pass)
- test object does not meet the requirement ........: F(Fail)
Testing:
Date(s) of receipt of test item ...............................: 2009-05-05
Date(s) of Performance of tests ...........................: 2009-05-05 to 2009-05-07
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.

"(see Enclosure #)" refers to additional information appended to the report.


"(see appended table)" refers to a table appended to the report.

Throughout this report a point is used as the decimal separator.

GENERAL PRODUCT INFORMATION:

Report Summary
All applicable tests according to the referenced standard(s) have been carried out.

Product Description
The PS3-2-1 is a powered speaker system that consists of the following:
Left Center / Surround speaker
Right Center / Surround speaker
Bass speaker which also houses the power supply and amplifier boards
SELV, low power Interface module with battery powered remote.

The remote was separately investigated to the requirements of IEC 60825.

Model Differences
For the PS3-2-1:
The 100V does not use an IEC 60127 approved fuse, it uses a MITI approved fuse which is acceptable for
JP.
This unit is turned ON by the use of a data cable.
The 220-240V version has a power switch.

For the PS3-2-1 II:


There are 3 different versions to this system.
The 100V and 120V units use the same transformer and have no power switch. This unit uses the same fuse

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 5 of 37 Report Reference # E176413-A31-CB-3

for Japan as the PS3-2-1.


The 220-240V unit has a power switch.
The 115/230V unit is a dual voltage unit with a voltage selector switch. This unit is turned ON by the use of a
data cable. No power switch is provided for this unit.

For the PS3-2-1 III:


This model is identical to Model PS3-2-1 II except for model number only.

CineMate digital home theater speaker system:


This model is similar to PS3-2-1 II except for a new I/O board, minor changes in secondary circuits and the
addition of an interface module. This unit comes in 120V, 115/230V and 220-240V

CineMate series II digital home theater system:


This model is similar to PS3-2-1 except it employs a switching power supply instead of linear and a revised
I/O board.

CineMate GS series II digital home theater system:


This model is similar to CineMate series II digital home theater system except for remote control and satellite
speakers.

Additional Information
This report is a reissue of CBTR Ref. No.: E176413-A31-CB-1, CB Test Certificate Ref. No. US/13959C/UL.
Based on the previosly conducted testing and the review of product technical documantation including
photos, schematics, wiring diagrams and similar, has been determined that the product continues to comply
with the standard. No additional tests were deemed necessary. All required tests were carried out under the
original investigation.

The product was investigated to the following additional standard EN 60065:2002 + A1:2006 + A11:2008.

Technical Considerations

 Equipment class: Class II,

 The product was investigated to the following additional standards: EN 60065:2002 + A1:2006 +
A11:2008

 This equipment was evaluated for a 45ºC tropical environment. --

Factory Location(s):
BOSE S A DE C V
AV MIGUEL DE LA MADRID, KM 9 1/2
CALLE DE LA INDSTRIA Y SAN LUIS
CARR SONOYTA PARQUE IND
RIO COLORADO
SON MEXICO

BOSE CORP S A DE C V
PARQUE CHILPANCINGO 2
ENTRE CALLE IN' L Y CHILPANCINGO

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 6 of 37 Report Reference # E176413-A31-CB-3

CALLE CHILPANCINGO 52
TIJUANA
BC MEXICO

BOSE IRELAND
CASTLEBLAYNEY ROAD CARRICKMACROSS
COUNTY MONAGHAN
IRELAND
Attachments to Test Report
National Differences (59 pages)
Enclosures (169 pages)

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 7 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

3 GENERAL REQUIREMENTS Pass


Safety class of the apparatus ................................ : Class II. Pass

4 GENERAL CONDITIONS OF TESTS Pass


4.1.4 Ventilation instructions require the use of the test Temperature measurements N/A
box were also carried out on an
open bench.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 8 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

5 MARKING Pass
Comprehensible and easily discernible Pass
Permanent durability against water and petroleum Pass
spirit
5.1 Identification, maker, model................................... : Refer to the Model information Pass
at the beginning of this Test
Report.
Class II symbol if applicable Pass
Rated supply voltage and symbol ......................... : Refer to the Rating information Pass
at the beginning of this Test
Report.
Frequency if safety dependant Refer to the Rating information Pass
at the beginning of this Test
Report.
Rated current or power consumption .................... : Refer to the Rating information Pass
at the beginning of this Test
Report.
5.2 Earth terminal N/A
Hazardous live terminals N/A
Supply output terminals (other than mains) N/A
5.3 Use of triangle with exclamation mark Pass
5.4 Instructions for use Only English language Pass
explanations were reviewed.
5.4.1 Mains powered equipment not exposed to dripping The instructions supplied with Pass
or splashing. Warning concerning objects filled with the apparatus were marked,
liquid, etc. with the required warning.
Hazardous live terminals, instructions for wiring N/A
Instructions for replacing lithium battery For remote control only. Pass
Instructions for modem if fitted N/A
Class I earth connection warning N/A
Instructions for multimedia system connection Pass
Special stability warning for fixed installation N/A
Warning: battery exposure to heat N/A
Warning: protective film on CRT face N/A
5.4.2 Disconnect device: plug/coupler or all-pole mains Appliance coupler. Pass
switch location, accessibility and markings

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 9 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

Instructions for permanently connected equipment N/A

6 HAZARDOUS RADIATION Pass


6.1 Ionizing radiation < 36 pA/kg (0,5 Mr/h) N/A
6.2 Laser radiation, emission limits to IEC 60825-1 .... : (See separate test report of Pass
IEC 60825-1 for Remote
Control)
Emission limits under fault conditions ................... : N/A

7 HEATING UNDER NORMAL OPERATING CONDITIONS Pass


7.1 Temperature rises not exceeding specified values, (see appended table 7.1) Pass
no operation of fuse links
7.1.1 Temperature rise of accessible parts (see appended table 7.1) Pass
7.1.2 Temperature rise of parts providing electrical N/A
insulation
7.1.3 Temperature rise of parts acting as a support or as N/A
a mechanical barrier
7.1.4 Temperature rise of windings (see appended table 7.1) Pass
7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 (see appended table 7.1) Pass
7.2 Softening temperature of insulating material N/A
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150°C

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 10 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

8 CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION Pass


AGAINST ELECTRIC SHOCK
8.1 Conductive parts covered by lacquer, paper, N/A
untreated textile oxide films and beads etc.
considered to be bare
8.2 No shock hazard when changing voltage setting Operations intended to be Pass
device, fuse-links or handling drawers etc. performed by hand do not
result in an increased risk of
shock hazard. (Dual voltage
units only)
8.3 Insulation of hazardous live parts not provided by Pass
hygroscopic material
8.4 No risk of electric shock following the removal of a N/A
cover which can be removed by hand
8.5 Class I equipment N/A
Basic insulation between hazardous live parts and N/A
earthed accessible parts
Resistors bridging basic insulation complying with N/A
14.2.1 a)
8.6 Class II equipment and Class II constructions Pass
within Class I equipment
Reinforced or double insulation between hazardous Pass
live parts and accessible parts
Components bridging reinforced or double Pass
insulation complying with 14.1 a) or 14.3
Basic and supplementary insulation each being N/A
bridged by a capacitor complying with 14.2.1 a)
Reinforced or double insulation being bridged with N/A
2 capacitors in series complying with 14.2.1 a)
Reinforced or double insulation being bridged with Pass
a single capacitor complying with 14.2.1 b)
Basic insulation bridged by components complying Pass
with 14.3.4.3
8.8 Basic or supplementary insulation > 0,4 mm ........ : N/A
Reinforced insulation > 0,4 mm............................. : N/A
Thin sheet insulation (excluding non-separable thin N/A
sheet insulation. See 8.22)
Basic or supplementary insulation, at least two N/A
layers, each meeting 10.3
Basic or supplementary insulation, three layers any N/A

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 11 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

two of which meet 10.3


Reinforced insulation, two layers each of which Pass
meet 10.3
Reinforced insulation, three layers any two which N/A
meet 10.3
8.9 Adequate insulation between internal hazardous N/A
live conductors and accessible parts
Adequate insulation between internal hazardous N/A
live parts and conductors connected to accessible
parts
8.10 Double insulation between conductors connected N/A
to the mains and accessible parts
8.11 Detaching of wires Hazardous voltage wiring Pass
connector terminations are
double crimped to both the
conductor and wire insulation.
No undue reduction of creepages or clearance Internal wiring that may Pass
distances if wires become detached become detached continues to
meet required creepage and
clearance distances after
evaluation of natural
movement.
Vibration test carried out........................................ : Yes Pass
8.13 Adequate fastening of windows, lenses, lamp N/A
covers etc. (pull test 20 N for 10 s)
8.14 Adequate fastening of covers (pull test 50 N for 10 N/A
s)
8.15 No risk of damage to the insulation of internal There was no contact with Pass
wiring due to hot parts or sharp edges sharp edges or hot parts while
a 2 N force was applied to
internal wiring.
8.16 Only special supply equipment can be used N/A
8.17 Insulated winding wire without additional N/A
interleaved insulation
8.18 Endurance test as required by 8.17 N/A
8.19 Disconnection from the mains Pass
8.19.1 Disconnect device ................................................. : The appliance coupler is used Pass
as the disconnect device and
information is provided in the
manual.
All-pole switch or circuit breaker with > 3mm N/A

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 12 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

contact separation
8.19.2 Mains switch ON indication The mains switch is marked Pass
with the on-position in
accordance with IEC 60417-
5007 ("I"). (PS 3-2-1 220-240V
model only)
8.20 Switch not fitted in the mains cord N/A
8.21 Bridging components comply with clause 14 N/A
8.22 Non-separable thin sheet material N/A

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 13 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS Pass


9.1 Testing on the outside Pass
9.1.1 For voltages >1000 V ac or >1500 V dc complies Voltages at inaccessible N/A
with clause 13.3.1 for basic insulation terminal contacts do not
exceed 1000 V ac or 1500 V
dc.
9.1.1.1 Touch current measured from terminal devices 0.38 MIU, U1: 0.102, U2: Pass
using the network in annex D ................................ : 0.028
Discharge not exceeding 45 µC N/A
Energy of discharge not exceeding 350 mJ N/A
9.1.1.2 Test with test finger and test probe The jointed test finger was Pass
unable to contact hazardous
live parts.
9.1.2 No hazardous live shafts of knobs, handles or Pass
levers
9.1.3 Ventilation holes tested by means of 4 mm x 100 Pass
mm test pin
9.1.4 Terminal devices tested with 1 mm x 20 mm test N/A
pin (10 N); test probe D of IEC 61032
Terminal devices tested with 1 mm x 100 mm N/A
straight wire (1 N); test probe D of IEC 61032
9.1.5 Pre-set controls tested with 2 mm x 100 mm test N/A
pin (10 N); test probe C of IEC 61032
9.1.6 No shock hazard due to stored charge on The voltage across mains plug Pass
withdrawal of the mains plug; voltage (V) after 2 s : pins 0V @ 2 sec.
If C is not greater than 0,1 µF no test needed N/A
9.1.7 Enclosure sufficiently resistant to external force Pass
Test probe 11 of IEC 61032 for 10 s (50 N) During application of force by Pass
the rigid test finger, the
enclosure did not become
hazardous live, hazardous live
parts did not become
accessible and textile
coverings did not contact
hazardous live parts.
Test hook of fig. 4 for 10 s (20 N) During application of the test Pass
hook, hazardous live parts did
not become accessible.
30 mm diameter test tool for 5 s (100 or 250 N) ... : During 250 N application of the Pass
circular plane test tool,
hazardous live parts the

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 14 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

enclosure did not become


hazardous live and hazardous
live parts did not become
accessible.
9.2 No hazard after removing a cover by hand N/A

10 INSULATION REQUIREMENTS Pass


10.1 Insulation resistance (M Ohms) at least 2 (M The insulation between the Pass
Ohms) min. after surge test for basic and 4 (M antenna terminals and mains
Ohms) min. for reinforced insulation ..................... : supply terminals was
subjected to surges and then
determined to comply with
10.3.
10.2 Humidity treatment 48 h or 120 h .......................... : 120 h Pass
10.3 Insulation resistance and dielectric strength Pass
between mains terminals
Insulation resistance and dielectric strength across N/A
basic and supplementary insulation (Class I)
Insulation resistance and dielectric strength across Pass
reinforced insulation (Class II)

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 15 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

11 FAULT CONDITIONS Pass


11.1 No shock hazard under fault condition Pass
11.2 Heating under fault condition (see appended table 11.2) Pass
No hazard from softening solder Pass
11.2.1 Measurement of temperature rises (see appended table 11.2) Pass
11.2.2 Temperature rise of accessible parts (see appended table 11.2) Pass
11.2.3 Temperature rise of parts, other than windings, Pass
providing electrical insulation
Temperature rise of printed circuit boards (PCB) N/A
exceeding the limits of table 3 by max. 100 K for
max. 5 min
a) Temperature rise of printed circuit boards (PCB) N/A
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
b) Temperature rise of printed circuit boards (PCB) N/A
to 20.1.3 up to 300 K for an area not greater than 2
cm² for a maximum of 5 min
Meets all the special conditions if conductors on N/A
printed circuit boards are interrupted
Class I protective earthing maintained N/A
11.2.4 Temperature rise of parts acting as a support or N/A
mechanical barrier
11.2.5 Temperature rise of windings Pass
11.2.6 Temperature rise of parts not subject to the limits of Pass
11.2.1 to 11.2.5

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 16 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

12 MECHANICAL STRENGTH Pass


12.1.1 Bump test where mass >7 kg Pass
12.1.2 Vibration test Pass
12.1.3 Impact hammer test Pass
Steel ball test Pass
12.1.4 Drop test for portable apparatus where mass < 7kg N/A
12.1.5 Thermoplastic enclosures strain relief test Pass
12.2 Fixing of knobs, push buttons, keys and levers N/A
12.3 Remote controls with hazardous live parts N/A
12.4 Drawers (pull test 50 N, 10 s) N/A
12.5 Antenna coaxial sockets providing isolation N/A
12.6 Telescoping or rod antennas construction N/A
12.6.1 Telescoping or rod antennas securement N/A

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 17 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

13 CLEARANCE AND CREEPAGE DISTANCES Pass


13.1 Clearances in accordance with 13.3 Pass
Creepage distances in accordance with 13.4 Pass
13.2 Determination of operating voltage Pass
13.3 Clearances Pass
13.3.2 Circuits conductively connected to the mains Pass
comply with table 8 and, where applicable, table 9
13.3.3 Circuits not conductively connected to the mains N/A
comply with table 10
13.4 Creepage distances Pass
Creepage distances greater than table 11 minima N/A
13.5 Printed boards Pass
13.5.1 Clearances and creepage distances between Pass
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
13.5.2 Type B coated printed circuit boards complying N/A
with IEC 60664-3 (basic insulation only)
13.6 Conductive parts along uncemented joints N/A
clearances and creepage distances comply with
13.3 and 13.4
Conductive parts along reliably cemented joints N/A
comply with 8.8
13.7 Enclosed, enveloped or hermetically sealed parts: N/A
not conductively connected to the mains:
clearances and creepage distances as in table 12
13.8 Parts filled with insulating compound, meeting the N/A
requirements of 8.8

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 18 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14 COMPONENTS Pass
14.1 Resistors N/A
a) Resistors between hazardous live parts and N/A
accessible metal parts
b) Resistors, other than between hazardous live N/A
parts and accessible parts
b) Resistors separately approved.......................... : N/A
14.2 Capacitors and RC units Pass
Capacitors separately approved Pass
14.2.1 Y capacitors tested to IEC 60384-14, 2nd edition. : C714, C715, C724 and C729 Pass
14.2.2 X capacitors tested to IEC 60384-14, 2nd edition. : C604 and C713 Pass
14.2.3 Capacitors operating at mains frequency but not N/A
connected to the mains: tests for X2 ..................... :
14.2.5 Capacitors with volume exceeding 1750 mm³, N/A
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better...................................................................... :
Capacitors with volume exceeding 1750 mm³, N/A
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ....................................... :
Shielded by a barrier to V-0 or metal..................... : N/A
14.3 Inductors and windings Pass
Comply with IEC 61558-1, IEC 61558-2 (as Pass
relevant) and clause 20.1.4
14.3.1 Transformers and inductors marked with (see appended table 14) Pass
manufacturer's name and type .............................. :
Transformers and inductors separately approved. : N/A
14.3.2 General Pass
14.3.3 Constructional requirements Pass
14.3.3.1 Clearances and creepage distances comply with Reinforced insulation between Pass
clause 13 Primary and Secondary
consists of 2 layers of material,
each of which meets the
dielectric strength test in 10.3.
14.3.3.2 Transformers meet the constructional requirements Pass
14.3.4.1 Class II transformers have adequate separation Bobbin thickness measures Pass
between hazardous live parts and accessible parts 0.9 mm thick.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 19 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

(double or reinforced insulation)


Coil formers and partition walls > 0,4 mm Pass
14.3.4.2 Class I transformers, with basic insulation and N/A
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.3 Separating transformers with at least basic N/A
insulation
14.3.5.1 Class II transformers have adequate insulation N/A
between hazardous live parts and accessible parts
(double or reinforced insulation)
Coil formers and partition walls > 0,4 mm N/A
14.3.5.2 Class I transformers have adequate insulation N/A
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Winding wires connected to protective earth have N/A
adequate current-carrying capacity
14.4 High voltage components Pass
High voltage components and assemblies: U > 4 Pass
kV (peak) separately approved
Component meets category V-1 of IEC 60707 Pass
14.4.1 High voltage transformers and multipliers tested as N/A
part of the submission
14.4.2 High voltage assemblies and other parts tested as N/A
part of the submission
14.5 Protective devices Pass
Protective devices used within their ratings Pass
External clearances and creepage distances meet Pass
requirement of clause 13 for the voltage across the
device when opened
14.5.1.1 a) Thermal cut-outs separately approved N/A
b) Thermal cut-outs tested as part of the N/A
submission
14.5.1.2 a) Thermal links separately approved (see appended table 14) Pass
b) Thermal links tested as part of the submission N/A
14.5.1.3 Thermal devices re-settable by soldering N/A
14.5.2.1 Fuse-links in the mains circuit according to IEC Pass

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 20 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

60127
14.5.2.2 Correct marking of fuse-links adjacent to holder ... : CineMate Series II/GS Series Pass
II: F600: T4AL, 250V
PS 3-2-1 (100V and 120V): F1:
T2.5AL, 250V
PS 3-2-1 (220-240V): F1:
T1.25AL, 250V
PS 3-2-1 II, PS 3-2-1 III,
CineMate: T1.6AL, 250V or
T2AL, 250V
14.5.2.3 Not possible to connect fuses in parallel ............... : Yes Pass
14.5.2.4 Not possible to touch hazardous live parts when N/A
replacing fuse-links without the use of a tool......... :
14.5.3 PTC-S thermistors comply with IEC 60730-1 N/A
PTC-S devices (15 W) category V-1 or better N/A
14.5.4 Circuit protectors have adequate breaking capacity Pass
and their position is correctly marked
14.6 Switches Pass
14.6.1a Separate testing to IEC 61058 including: Pass
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
14.6.1b Tested in the apparatus: N/A
Switch controlling > 0.2A with open contact N/A
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
Switch controlling > 0.2A with open contact N/A
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
Switch controlling < 0.2A with open contact N/A
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
14.6.2 Switch tested to 14.6.1 b) constructed to IEC N/A
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
14.6.3 Switch tested to 14.6.1 b) compliant with IEC N/A
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
14.6.4 Switch tested to 14.6.1 b) has adequate dielectric N/A
strength

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 21 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14.6.5 Mains switch controlling mains socket outlets N/A


additional tests to IEC 60058-1
Socket outlet current marking correct N/A
14.7 Safety interlocks N/A
Safety interlocks to 2.8 of IEC 60950 N/A
14.8 Voltage setting devices Voltage selector selects Pass
between 115 V and 230 V.
Voltage setting device not likely to be changed 115/230V model only Pass
accidentally
14.9 Motors N/A
14.9.1 Endurance test on motors N/A
Motor start test N/A
Dielectric strength test N/A
14.9.2 Not adversely affected by oil or grease etc. N/A
14.9.3 Protection against moving parts N/A
14.9.4 Motors with phase-shifting capacitors, three-phase N/A
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
14.10 Batteries Battery located in Remote Pass
Control
14.10.1 Batteries mounted with no risk of accumulation of Pass
flammable gases
14.10.2 No possibility of recharging non-rechargeable N/A
batteries
14.10.3 Recharging currents and times within N/A
manufacturers limits
Lithium batteries discharge and reverse currents Pass
within the manufacturers limits
14.10.4 Battery mould stress relief N/A
14.10.5 Battery drop test N/A
14.11 Optocouplers Pass
Optocouplers comply with Cl. 8 Pass
Internal and external dimensions to 13.1. or Pass
alternatively 13.6 (jointed insulation)
14.12 Surge suppression varistors Pass
Comply with IEC 61051-2 Pass

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 22 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

Not connected between mains and accessible Pass


parts except for earthed parts of permanently
connected apparatus
Complies with the current pulse, fire hazard and N/A
thermal stress requirements of 14.12

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 23 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

15 TERMINALS Pass
15.1.1 Mains plug, appliance inlet, interconnection N/A
couplers and mains socket-outlet meet the
appropriate standard
15.1.2 Connectors for antenna, earth, audio, video or data: Pass
No risk of insertion in mains socket-outlets N/A
No risk of insertion into audio or video: outlets The apparatus has no outlets N/A
marked with the symbol of 5.2 that are marked with the
symbol of 5.2.
15.1.3 Output terminals of a.c. adaptors or similar devices N/A
not compatible with household mains socket-
outlets
15.2 Provision for protective earthing N/A
Accessible conductive parts of Class I equipment N/A
reliably connected to earth terminal, within
equipment
Protective earth conductors correctly coloured N/A
Equipment with non-detachable mains cord N/A
provided with separate protective earth terminal
near mains input
Protective earth terminal resistant to corrosion N/A
Earth resistance test: < 0,1 ohms at 25 A ............. : N/A
15.3 Terminals for external flexible cords and for N/A
permanent connection to the mains supply
15.3.1 Adequate terminals for connection of permanent N/A
wiring
15.3.2 Reliable connection of non-detachable cords: N/A
Not soldered to conductors of a printed circuit N/A
board
Adequate clearances and creepage distances N/A
between connections should a wire break away
Wire secured by additional means to the conductor N/A
15.3.3 Screws and nuts clamping conductors have N/A
adequate threads: ISO 261, ISO 262 or similar
15.3.4 Soldered conductors wrapped around terminal prior N/A
to soldering or held in place by additional means
Clamping of conductor and insulation if not N/A
soldered or held by screws

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 24 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

15.3.5 Terminals allow connection of appropriate cross- N/A


sectional area of conductors, for the rated current
of the equipment
15.3.6 Terminals to 15.3.3 have sizes required by table 16 N/A
15.3.7 Terminals clamp conductors between metal and N/A
have adequate pressure
Terminals designed to avoid conductor slipping out N/A
when tightened or loosened
Terminals adequately fixed to avoid loosening N/A
when the clamping is tightened or loosened and
stress on internal wiring is avoided
15.3.8 Terminals carrying a current more than 0,2 A: N/A
contact pressure not transmitted by insulating
material except ceramic
15.3.9 Termination of non-detachable cords: wires N/A
terminated near to each other
Terminals located and shielded: test with 8 mm N/A
strand
15.4 Devices forming a part of the mains plug N/A
15.4.1 No undue strain on mains socket-outlets N/A
15.4.2 Device complies with standard for dimensions of N/A
mains plugs
15.4.3 Device has adequate mechanical strength (tests N/A
a,b,c)

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 25 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

16 EXTERNAL FLEXIBLE CORDS Pass


16.1 Mains cords sheathed type, complying with IEC PVC Pass
60227 for PVC or IEC 60245 for synthetic rubber
cords ...................................................................... :
Non-detachable cords for Class I have N/A
green/yellow core for protective earth
16.2 Mains cords conductors have adequate cross- Pass
sectional area for rated current consumption of the
equipment
16.3 a) Flexible cords not complying with 16.1, used for N/A
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
b) Flexible cords not complying with 16.1, N/A
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
16.4 Flexible cords used for connection between Pass
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
16.5 Adequate strain relief on external flexible cords N/A
Not possible to push cord back into equipment N/A
Strain relief device unlikely to damage flexible cord N/A
For mains cords of Class I equipment, hazardous N/A
live conductors become taut before earth conductor
16.6 Apertures for external flexible cord: no risk of Pass
damage to the cord during assembly or movement
in use
16.7 Transportable musical instruments and amplifiers N/A
fitted with detachable cord set with appliance inlet
to IEC 60320-1
Transportable musical instruments and amplifiers N/A
fitted with detachable cord sets or with means of
stowage to protect the cord

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 26 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

17 ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS Pass


17.1 Torque test to table 20: Cover fixing screws Pass
- screws into metal: 5 times N/A
- screws into non-metallic material 10 times Pass
17.2 Correct introduction into female threads in non- Pass
metallic material
17.3 Cover fixing screws: captive N/A
Non-captive fixing screws: no hazard when N/A
replaced by a screw whose length is 10 times its
diameter
17.4 No loosening of conductive parts carrying a current N/A
> 0,2 A
17.5 Contact pressure not transmitted through plastic N/A
other than ceramic for connections carrying a
current > 0,2 A
17.6 Stranded conductors of flexible supply cords N/A
carrying a current > 0,2 A with screw terminals not
consolidated by solder
17.7 Cover fixing devices other than screws have N/A
adequate strength and their positioning is
unambiguous
17.8 Fixing devices for detachable legs or stands N/A
provided
17.9 Internal pluggable connections, affecting safety, N/A
unlikely to become disconnected

18 MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST N/A


THE EFFECTS OF IMPLOSION

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 27 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

19 STABILITY AND MECHANICAL HAZARDS Pass


Mass of the equipment exceeding 7 kg................. : 13 kg Pass
Apparatus intended to be fastened in place - N/A
suitable instructions
19.1 Test on a plane, inclined at 10°C to the horizontal Pass
19.2 100 N force applied vertically downwards Pass
19.3 100 N force, or 13% of weight, applied horizontally N/A
to point of least stability
19.4 Edges or corners not hazardous Pass
19.5 Glass surfaces (excluding laminated) with an area N/A
exceeding 0,1 m² or maximum dimension > 450
mm, pass the test of 19.5.1
19.6 Wall or ceiling mountings adequate N/A

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 28 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

20 RESISTANCE TO FIRE Pass


20.1 Electrical components and mechanical parts Pass
a) Exemption for components contained in an Pass
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
b) Exemption for small components as defined in Pass
20.1
20.1.1 Electrical components meet the requirements of Pass
Clause 14 or 20.1.4
20.1.2 Insulation of internal wiring working at voltages > 4 N/A
kV or leaving an internal fire enclosure, not
contributing to the spread of fire
20.1.3 Material of printed circuit boards on which the Pass
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Material of printed circuit boards on which the Pass
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
20.1.4 Components and parts not covered by 20.1.1, N/A
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Components and parts as above but shielded from N/A
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
20.2 Fire enclosure Pass
20.2.1 Potential ignition sources with open circuit voltage N/A
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2 Internal fire enclosures with openings not N/A
exceeding 1 mm in width and with openings for
wires completely filled
20.2.3 Requirements of 20.2.1 and 20.2.2 met by an N/A
internal fire enclosure

A APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH N/A


PROTECTION AGAINST SPLASHING WATER

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 29 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

B APPENDIX B, APPARATUS TO BE CONNECTED TO THE N/A


TELECOMMUNICATION NETWORKS

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 30 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

7.1 TABLE: temperature rise measurements Pass


Power consumption in the OFF/Stand-by ............. 0.48 W Pass

Position of the functional switch (W)...................... - —


Operating conditions
Standard Signal input, all channels driven, 1/8 non-clipped output power, Bass = 2 Ohm, SAT = 4 Ohm output
loads
Un(V) In(A) Pn(W) Pout(W)
264 c) 0.28 38 B = 2.8, Lc = 1.1, Ls = 1.1, Rc =
1.1, Rs = 1.1

Loudspeaker impedance() ............. Bass = 2 Ohm, Sat = 4 Ohm —


Several loudspeaker systems ........... - N/A
Marking of loudspeaker terminals..... - N/A
Monitored point: dT (K) Limit dT (K)
Ambient 23.0 -
J702 PCB 39.7 100.0
D703 57.5 100.0
L703 42.6 70.0
C719 39.4 70.0
C710 36.8 70.0
T701 on C721 side 50.5 55.0
T701 on C719 side 52.6 55.0
HS top near DSP 32.1 100.0
J701 PCB 27.1 100.0
L705 31.1 70.0
BR701 PCB 33.4 100.0
L702 34.6 70.0
L702 33.4 70.0
Q701 PCB 59.7 100.0
U702 PCB 52.2 100.0
U250 PCB 30.6 100.0
U350 PCB 23.1 100.0
C22 9.9 70.0
J5 PCB 3.8 100.0
Enclosure top 8.4 40

Winding temperature rise measurements


Ambient temperature t1 (°C) : - -
Ambient temperature t2 (°C) : - -
Temperature rise dT of R1 () R2 () dT(K) Limit dT(K) Insulation class
winding:

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 31 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

- - - - - -
supplementary information:
CineMate series II digital home theater system and CineMate GS series II digital home theater system

7.2 TABLE: softening temperature of thermoplastics N/A


Temperature T of part T-normal conditions (°C) T-fault conditions (°C) T softening
(°C)

supplementary information:

10.3 TABLE: insulation resistance measurements Pass


Insulation resistance R between: R (M) Required R (M)
Between mains poles (primary fuse disconnected) 50 2
Between parts separated by basic or supplementary insulation - 2
Between parts separated by double or reinforced insulation 106.9 4
- - -
supplementary information:
-

10.3 TABLE: electric strength measurements Pass


Test voltage applied between: Test voltage (V) Breakdown
Mains poles (primary fuse disconnected) 1500 No
Between parts separated by basic or supplementary insulation - -
Between parts separated by double or reinforced insulation 3000 No
- - -
supplementary information:
-

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 32 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

11.2 TABLE: summary of fault condition tests Pass


Voltage (V) 0.9 or 1.1 times rated voltage............. : 264 —
Ambient temperature (°C) ...................................... : - —
Monitored point: Under fault conditions specified below dT (K) Limit dT (K)
OL - C718 (PS PCB): - -
T701 near C721 81.0 90
T701 near C719 71.7 90
D703 PCB 125.3 150
Heatsink top near DSP 15.0 70
Enclosure top 11.7 45
Rm Ambient 22.7 -
- - -
Maximum Power - -
Ambient 23.0 -
J702 PCB 70.6 150.0
D703 103.2 150.0
L703 82.2 100.0
C719 61.9 105.0
C710 54.3 70.0
T701 on C721 side 76.0 90.0
T701 on C719 side 79.3 90.0
HS top near DSP 42.3 100.0
J701 PCB 39.4 150.0
L705 45.9 70.0
BR701 PCB 50.5 150.0
L702 53.0 70.0
L702 51.3 70.0
Q701 PCB 91.3 150.0
U702 PCB 66.2 150.0
U250 PCB 42.6 150.0
U350 PCB 31.4 150.0
C22 12.6 70.0
J5 PCB 5.2 150.0
Enclosure top 9.6 45.0
- - -
Blocked Vents - -
Ambient 23.0 -
J702 PCB 49.1 150.0
D703 66.0 150.0
L703 52.1 100.0
C719 48.5 105.0
C710 46.1 70.0
T701 on C721 side 59.5 90.0
T701 on C719 side 61.5 90.0
HS top near DSP 42.4 100.0

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 33 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

J701 PCB 36.5 150.0


L705 40.6 70.0
BR701 PCB 42.8 150.0
L702 44.1 70.0
L702 43.2 70.0
Q701 PCB 70.4 150.0
U702 PCB 61.6 150.0
U250 PCB 40.6 150.0
U350 PCB 31.6 150.0
C22 15.7 70.0
J5 PCB 9.5 150.0
Enclosure top 10.8 45.0
Winding temperature rise measurements
Ambient temperature t1 (°C).................................. : - —
Ambient temperature t2 (°C).................................. : - —
supplementary information:
-

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 34 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14 TABLE: list of critical components Pass


object/part No. manufacturer/ type/model technical data standard mark(s) of
trademark conformity1)
CineMate series - - - - -, -
II/GS series II
AC Inlet Kunming KM01002A-P 250V, 2.5A UL498, UR, S
Electronics EN60320-1
Input connector JST Corp. B(2)P(3)-VH-BB 250V, 7A - UR, TUV
Fuse - F600 Littelfuse 392 250V, 4A UL248, UR, VDE
IEC60127
Varistor - VR601 Littelfuse or V275LC20AP 275Vrms UL1414 UR, VDE
Harris (275L20)
Differential Mode Wurth Elektronik S09100022 100uH - -, -
Choke - L601
X-Cap - C604, Arcotronics R.46# X2, 275V, 0.1uF UL1414, UR, ENEC
C713 IEC60384-14
Input connector JST Corp. S2P3- 250V, 7A - UR, TUV
VH(LF)(SN)
Output connector JST Corp. SXP-VH(LF)(SN) 250V, 7A - UR, TUV
Output Choke - Toko America AR621LY-2R2M 2.2uH - -, -
L703, L704,
L705 - Alternate
Output Choke - Toko America AR823LY-2R2M 2.2uH - -, -
L703, L704,
L705
Common Mode Wurth Elektronik 7448640411 3.3mH - -, -
Choke - L702
Y1 Capacitors - Murata KX 1000pF, 250V IEC60384-14 UR, VDE, S, N,
C724, C714 BSI
Y1 Capacitors - Murata KX 470Pf, 250V IEC60384-14 UR, VDE, S, N,
C729, C715 BSI
Transformer - Billion 98S-042 Class F IEC60065 UR, TUV
T701
Optocouplers - Vishay, Everlight CNY17F-1 or Suitable for UL1577, UR, VDE
Q708, Q709 or Infineon CNY17F-1x Double IEC60747
(where "x": Protection
optional any
number)
Unique to PS3-2- - - - - -, -
1, 100V unit
Appliance inlet Kunming HJC-027A; or 250V, 2.5A EN60320, UR, S
Electronics KM01001A-P; or UL498
KM01002A-P
Primary fuse - F1 Littelfuse 229 02.5 T2.5A L, 250V UL248, UR, MITI
IEC60127
Primary Japan Solderless VA; B2P3-VH 250V, 7A UL1977 UR, TUV
connector Terminal Corp.

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 35 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14 TABLE: list of critical components Pass


object/part No. manufacturer/ type/model technical data standard mark(s) of
trademark conformity1)
Primary Japan Solderless VA, VAR-2 250V, 7A UL1977 UR, TUV
connector Terminal Corp.
(transformer)
Primary wire Various Double insulated 300V, 105°C, - UR, -
(transformer) VW-1, #22AWG
Secondary wire Various Single insulated 600V, 105°C, - UR, -
(transformer) VW-1, #18AWG
Thermal fuse Uchihashi Estec Type X23 130°C, 3A, 250V UL60691, UR, VDE
(transformer) Co., Ltd. Japan EN60691
Transformer Billion Electric 90TS-118 AC100V, Class - -, -
Co., Ltd. B (130°C)
Varistor Harris or V275LC20A 275Vrms UL1414 UR, VDE
Littelfuse (275L20)
PS3-2-1, 120V - - - - -, -
version (same as
100V version
except as
follows)
Primary fuse - F1 Littelfuse 229 02.5 T2.5A L, 250V UL248, UR, VDE
IEC60127
Varistor Harris or V150LC10A 150Vrms UL1414 UR, VDE
Littelfuse (150L10)
Transformer Billion Electric 89TS-084 Class B (130°C) - -, -
Co., Ltd.
Primary wire Various Style UL1672 AWG #20-22 - UR, -
(Transformer)
Secondary wire Various Style UL1015 AWG #18-22 - UR, -
(Transformer
PS3-2-1, 220- - - - - -, -
240V version
(Same as 100V
version except
as follows)
Primary Fuse - Littelfuse 218 1.25 T1.25A L, 250V UL248, UR, VDE
F1 IEC60127
Mains Switch Marquardt 1551 16(4)A, 250V UL1054, UR, VDE
GmbH EN60158
Transformer Billion Electric 90TS-117; Class B (130°C) - -, -
Co., Ltd. 90TS-117F
PS3-2-1 II, PS3- - - - - -, -
2-1 III, CineMate;
same as PS3-2-
1 except for the
following (no
varistor on

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 36 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14 TABLE: list of critical components Pass


object/part No. manufacturer/ type/model technical data standard mark(s) of
trademark conformity1)
Series II and
series III models)
Primary fuse Littelfuse 218 01.6 T1.6A L, 250V IEC60127, UR, S
(220-240Vac UL248
Unit)
Primary fuse Littelfuse 218 002 T2A L, 250V IEC60127, UR, S
(115/230Vac UL248
Unit)
Selector switch, Marquardt 4021 5A, 250V EN61058, UR, VDE
dual voltage UL1054
Transformer Billion Electric 261276-ZXXX Class B, 220- IEC60065 -, -
Co., Ltd. 240V
Transformer Billion Electric 261277-102 Class B, IEC60065 -, -
Co., Ltd. 115/230V
Transformer Billion Electric 261278-ZXXX Class B, 100V, IEC60065 -, -
Co., Ltd. 120V
Thermal fuse (all Anzen Dengu H4F 127°C, 3A UL60691, UR, VDE
transformers) Co., Ltd. EN60691
All models - - - - -, -
Label material Various Flexcon MM Flexcon MM IEC60065 -, -
500-S 500-S with
thermal transfer
printable 2mil
compucal cap
Flexcon PM-200-
C MT/C 329;
with Flexcon L-
156 adhesive
Printed Circuit Various Various V-0 min, 130ºC UL796 UR, -
Boards
Rear enclosure Sabic Innovative Cycoloy C6600 V-2 min. at UL94 UR, -
plastic Plastics 1.5mm
Front enclosure Ineos ABS Lustran 448 HB min. at UL94 UR, -
plastic (USA) Corp. 1.5mm
Top/Sides/Botto Various Various Wood, Min. 13 - -, -
m mm thick
EU, Power cord Various HO3VVH2-F2 2*0.75mm², - -, VDE or
2.5A, 125V equivalent
AU, Power cord Various - 2*0.75mm², - -, SECV, SAA or
2.5A, 250V equivalent
JP, Power cord Unielec VCTFK 2*0.75mm, 7A, - -, MITI
125V
UK, Power cord Various HO3VVH2-F2 2*0.75mm², - -, ASTA, BSI or
2.5A, 250V equivalent

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 37 of 37 Report Reference # E176413-A31-CB-3

IEC/EN 60065
Clause Requirement + Test Result - Remark Verdict

14 TABLE: list of critical components Pass


object/part No. manufacturer/ type/model technical data standard mark(s) of
trademark conformity1)
Remote - Bose 285104 Class III battery IEC60825 -, TUV
CineMate GS operated. Class
Model Only I LED
Remote - All Bose 318809 Class III battery IEC60825 -, TUV
models except operated. Class
CineMate GS I LED
Lithium Battery TOSHIBA CR2032 3 VDC UL1642 UR File
for Remote HOME MH12828, -
Control APPLIANCES
CORP
Lithium Battery EVEREADY CR2032 3 VDC UL1642 UR File
for Remote BATTERY CO MH12454, -
Control INC
Lithium Battery SANYO CR2032 3 VDC UL1642 UR File
for Remote ENERGY (U S MH12383, -
Control A) CORP
Lithium Battery DURACELL INC DL2032 3 VDC UL1642 UR File
for Remote MH12538, -
Control
1
) an asterisk indicates a mark which assures the agreed level of surveillance

TRF No.: IEC60065_I Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 1 of 59 Report Reference # E176413-A31-CB-3

Enclosure
National Differences

Argentina
Australia / New Zealand
Austria**
Belgium**
Canada
China*
Czech Republic**
Denmark
Finland
France**
Germany
Greece**
Group
Hungary**
Italy
Japan
Korea
Malaysia
Netherlands**
Norway
Poland**
Portugal**
Singapore*
Slovakia**
Slovenia**
Sweden
Switzerland**
Ukraine*
United Kingdom
United States

* No National Differences Declared


** Only Group Differences

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 2 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Argentina - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


3 Class 0 and 0I appliances are not allowed Pass
4.2.1 Ratings cover 220 V ac, 50 Hz Pass
5.1 Country of origin shall be shown on marking plate Pass
or, if not possible, in the primary packaging
(Resolution 92/98)
5.1 Address of the importer in Argentina shall be Pass
shown on the product or the primary packaging
(Resolution 92/98)
5.1 Class I appliances provided with plugs shall be N/A
provided with the label specified in sheet "Class I"
(Disposition 731/87)
5.1 Class II appliances shall be provided with plugs Pass
provided with the label specified in sheet "Class II"
(Disposition 731/87)
5.1 Appliances certified under System Nº 4 (Type N/A
Certification scheme) shall be marked with the
symbol specified in sheet "St Mark" (Resolution
197/04)
5.1 Appliances certified under System Nº5 (Mark of N/A
Conformity Certification scheme) shall be marked
with the symbols specified in sheet "S Mark"
(Resolution 799/99)
5.4 Safety instructions and manuals shall be written in See Manufacturer's Pass
Spanish language (Resolution 92/98) Declaration Letter.
15.1.1 Plugs for Class I appliances comply with IRAM N/A
2073 (Resolution 524/98)
15.1.1 Plugs for Class II appliances comply with IRAM Pass
2063 (Resolution 524/98)
15.1.1 Integral plug blades on adaptors/transformers for N/A
Class I appliances comply with the geometry of
IRAM 2073 (Resolution 524/98)
15.1.1 Integral plug blades on adaptors/transformers for Pass
Class II appliances comply with the geometry of
IRAM 2063 (Resolution 524/98)

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 3 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Australia / New Zealand - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


7.1.5 In Table 3 under item c) add an h) in both columns N/A
against "thermoplastic materials"
Footnote h): As an alternative to the method
described in footnote f) the following variation may
be used where there is any doubt about the
suitability of the material: "The ball-pressure test
described in AS/NZS 60695.10.2 may be carried
out."
7.1.5 To assess compliance under normal operating N/A
conditions, the test made in a heating cabinet at a
temperature of 40°C ± 2°C plus the maximum
temperature rise determined under normal
operating conditions, but at least:
- 75°C ± 2°C for external parts
- 125°C ± 2°C for materials supporting parts
conductively connected to the mains
7.2 After the second paragraph, add the following: N/A
The alternative method described in footnote h) of
Table 3 may be used.
15.1.1 After the second paragraph, add the following: Pass
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
15.1.1 Apparatus with a plug portion, suitable for insertion Pass
into a 10 A 3-pin flat-pin socket-outlet complying
with AS/NZS 3112, shall comply with the
requirements of AS/NZS 3112 for equipment with
integral pins for insertion into socket-outlets.
15.3.5 In Table 15, in the second and third rows of the first N/A
column replace "6" with "7.5".
16.2 In Table 18, in the second and third rows of the first Pass
column replace "6" with "7.5".
16.3 In item (b), add the following: N/A
A flexible cord complying with AS/NZS 3191 need
not undergo this test.
20 Add the following after NOTE 2: Pass
For alternative test refer to Clause 20.201.
20.1.4 In Table 21, in the third and fourth columns change N/A
both "HB75" and "No requirement" to "V-1".
20.201 General N/A
Parts of non-metallic material shall be resistant to ignition and the spread of fire
20.201.1 This requirement does not apply to decorative N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 4 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

trims, knobs and other parts unlikely to be ignited


or to propagate flames originating from inside the
apparatus or the following:
20.201.1 This requirement does not apply to decorative N/A
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus or the following:
20.201.1 a) Components that are contained in an enclosure N/A
having a flammability category of V-0 according to
AS/NZS 60695.11.10 and having openings only for
the connecting wires filling the openings
completely, and for ventilation not exceeding 1 mm
in width regardless of length
20.201.1 b) The following parts which would contribute N/A
negligible fuel to a fire:
- small mechanical parts, the mass of which does
not exceed 4g, such as mounting parts, gears,
cams, belts, and bearings;
- small electrical components, such as capacitors
with a volume not exceeding 1 750 mm³, integrated
circuits, transistors and optocoupler packages, if
these components are mounted on material of
flammability category V-1 or better according to
AS/NZS 60695.11.10.
20.201.1 NOTE - In considering how to minimize N/A
propagation of fire and what "small parts" are,
account should be taken of the cumulative effect of
small parts adjacent to each other for the possible
effect of propagation fire from one part to another.
Compliance shall be checked by the tests of
20.201.2.1, 20.201.2.2 and 20.201.2.3
20.201.1 For the base material of printed boards, N/A
compliance shall be checked by the test of
20.201.2.4
20.201.1 The tests shall be carried out on parts of non- N/A
metallic material which have been removed from
the apparatus. When the glow-wire test carried out
on parts placed in the same orientation, as they
would be in normal use. These tests are not carried
out on internal wiring
20.201.2.1 Testing of non-metallic parts N/A
20.201.2.1 Parts of non-metallic material shall be subjected to N/A
the glow-wire test of AS/NZS 60695.2.11 which
shall be carried out at 550°C
20.201.2.1 Parts for which the glow-wire test cannot be carried N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 5 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

out, such as those made of soft or foamy material,


shall meet the requirements specified in ISO 9772
for category FH-3 material
20.201.2.1 The glow-wire test shall not be carried out on parts N/A
of material classified at least FH-3 according to ISO
9772 provided that the sample tested was not
thicker than the relevant part
20.201.2.2 Testing of insulated parts N/A
20.201.2.2 Parts of insulating material supporting potential N/A
ignition sources shall be subjected to the glow-wire
test of AS/NZS 64695.2.11 which shall be carried
out at 750°C
20.201.2.2 The test shall be also carried out on other parts of N/A
insulating material, which are within a distance of 3
mm of the connection.
(Note - Contacts in components such as switch
contacts are considered to be connections.)
20.201.2.2 For parts which withstood the glow-wire test but N/A
produce a flame, other parts above the connection
within the envelope of a vertical cylinder having a
diameter of 20 mm and a height of 50 mm shall be
subjected to the needle-flame test
20.201.2.2 However, parts shielded by a barrier, which meets N/A
the needle-flame test, need not be tested.
20.201.2.2 The needle-flame test shall not be carried out on N/A
parts of material classified as V-0 or V-1 according
to AS/NZS 60695.11.10 provided that the sample
tested was not thicker than the relevant part.
20.201.2.2 The needle-flame test shall be made in accordance N/A
with AS/NZS 4695.2.2 with the following
modifications:
5 - Severities - Replace with: The duration of
application of the test flame 30 s ± 1 s."
8 - Test procedure
8.2 - Replace the first sentence with: "The
specimen shall be arranged so that the flame can
be applied to a vertical or horizontal edge as shown
in the examples of figure 1."
8.4 - The first paragraph does not apply.
Addition: "If possible, the flame shall be applied at
least 10 mm from a corner."
8.5 - Replace with: "The test shall be made on one
specimen. If the specimen does not withstand the
test, the test may be repeated on two further
specimens, both of which shall then withstand the

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 6 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

test."
10 - Evaluation of test results - Replace with: "The
duration of burning (tb) shall not exceed 30 s.
However, for printed circuit boards, it shall not
exceed 15 s."
20.201.2.3 Testing by needle-flame test N/A
20.201.2.3 If parts, other than enclosures, do not withstand the N/A
glow wire test of 20.201.2.2, by failure of extinguish
within 30 s after the removal of the glow-wire tip,
the needle-flame test detailed in 20.201.2.2 shall
be made on all parts of non-metallic material which
are within a distance of 50 mm or which are likely
to be impinged upon by flame during the tests of
20.201.2.2.
20.201.2.3 Parts shielded by a separate barrier, which meets N/A
the needle-flame test shall not be tested
20.201.2.3 NOTE 1 - If the enclosure does not withstand the N/A
glow-wire test, the appliance is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
20.201.2.3 NOTE 2 - If other parts do not withstand the glow- N/A
wire test due to ignition of the tissue paper and if
this indicated that burning or glowing particles can
fall onto an external surface underneath the
apparatus, the apparatus is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
20.201.2.3 NOTE 3 - Parts likely to be impinged upon by the N/A
flame are considered to be those within the
envelope of a vertical cylinder having a radius of 10
mm and a height equal to the height of the flame,
positioned above the point of the material
supporting, in contact with, or in close proximity to,
connections.
20.201.2.4 Testing of printed boards N/A
20.201.2.4 The base material of printed boards shall be N/A
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the edge
of the board where the heatsink effect is lowest
when the board is positioned as in normal use. The
flame shall not be applied to an edge consisting of
broken perforations, unless the edge is less than 3
mm from a potential ignition source.
20.201.2.4 The test is not carried out if the printed board: (1) N/A
does not carry any potential ignition source, or (2)

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 7 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

is protected by an enclosure meeting the


flammability category V-0 per AS/NZS
60695.11.10, or made of metal, having openings
only for connecting wires which fill the openings
completely.
20.201.2.4 The test is not carried out on printed board base N/A
material: (1) on which the available power at a
connection exceeds 15 VA operating at a voltage
exceeding 50 V and equal or less than 400 V
(peak) a.c. or d.c. under normal operating
conditions, or (2) that is flammability category V-1
or better according to AS/NZS 60695.11.10, or (3)
on which the available power at a connection
exceeds 15 VA operating at a voltage exceeding
400 V (peak) a.c. or d.c. under normal operating
conditions, and base material of printed board
supporting spark gaps which provides protection
against overvoltages is of flammability category V-0
according to AS/NZS 60695.11.10 or the printed
boards are contained in a metal enclosure, having
openings only for connecting wires which fill the
openings completely. NOTE - Available power is
the maximum power, which can be drawn from the
supplying circuit through a resistive load whose
value is chosen to maximize the power for more
than 2 min when the circuit supplied is
disconnected.
20.201.2.4 Compliance was determined using the smallest N/A
thickness of the material.
21.201.3 For open circuit voltages greater than 4 kV, N/A
potential ignition sources with open circuit voltages
exceeding 4 kV (peak) a.c. or d.c. under normal
operating conditions shall be contained in a fire
enclosure which shall comply with flammability
category V-1 or better according to AS/NZS
60695.11.10.
B Add after the heading: For Australia only, this N/A
Annex is replaced by the requirements of the
Telecommunications Labeling Notice issued under
the Telecommunications Act by the Australian
Communications Authority

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 8 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Canada - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


1.1.1 This Standard applies to the safety of such Pass
equipment designed to be installed and used in
accordance with the rules of the Canadian
Electrical Code (CEC), Part I.
3.2A A component power supply complying with N/A
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions of
this Standard after taking into account any relevant
conditions of acceptability.
4.2.1 Add after the fifth paragraph: For apparatus Pass
intended for use at nominal 120 V ac, the
apparatus shall comply with this Standard at supply
voltages between 108 and 125 V. For apparatus
intended for use at nominal 240 V ac, the
apparatus shall comply with this Standard at supply
voltages between 21 6 and 250 V.
4.2.10 Add after the second paragraph: As an alternative, Pass
a supply apparatus for general use complying with
CAN/CSA-C22.2 No. 223 or CAN/CSA-C22.2 No.
60950 shall be acceptable.
5 Adhesive nameplates on commercial products shall N/A
comply with CSA C22.2 No. 0.15.
5.1 h A) date of manufacture: a date or code identifying Pass
the period of manufacture shall be marked on the
apparatus;
5.3A Where a loudspeaker grille, removable from the N/A
outside, is relied on as part of the enclosure (see
Clause 9.2), the following marking or equivalent
shall be visible on the enclosure after removal of
the grille:

"Caution - To prevent electric shock hazard,


replace grille.''

Alternatively, the symbol in Clause 5.2 b) shall be


visible after removal of the grille, and the caution
wording above shall appear in the user instructions,
accompanied by the symbol.

Compliance is checked by inspection.


8.9 Wiring in circuits with voltages higher than 42 V N/A
peak shall comply with CSA C22.2 No. 127 or
CAN/CSA-C22.2 No. 210.2.
9.1.1A For cord-connected Class I apparatus, the leakage N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 9 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

current through the safety earthing conductor,


expressed as voltages U1, and U2, shall not
exceed U1 =105 V (peak) and U2, = 1.05 V (peak)
(1.5 mA).

Apparatus having a leakage current between 0.75


mA and 1.5 mA shall be provided with a caution
label on the mains cord with the following, or
equivalent:

"CAUTION -TO REDUCE THE RISK OF


ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
9.2 [Add the following after the second paragraph] N/A
This requirement applies also to internal parts of
loudspeaker systems that become accessible by
removal of a loudspeaker grille from the outside
either by hand or with the use of a tool, coin, or
other object. In such cases, the apparatus shall be
marked according to Clause 5.3A.
9.2 [Replace the third paragraph with the following] N/A
Compliance is checked by inspections and by
application of the tests of Clause 9.1.l, except that
the measurements are made 2 s after removal of
the cover or grille.
10.2A If equipment is installed in environments where the N/A
enclosure is required to prevent ingress of water or
dust, the enclosure shall be classified as a type
recognized by the Canadian Electrical Code, Part I,
and shall comply with the requirements of
CAN/CSA-C22.2 No. 94.
11.2 Flammable gases shall not be emitted from a Pass
component for more than 10 secs.
12.3A Television Impact Test N/A
12.3A.1 For television sets and similar apparatus using a N/A
cathode ray tube larger than 160 mm diagonally,
the top, sides, front, and rear of the enclosure,
including the safety screen where provided, shall
be capable of withstanding a single impact of 7 J in
accordance with Clause 12.3A.2 without
developing any opening larger than 130 mm2 in the
enclosure of the cathode ray tube, unless the minor
dimension of any opening is not more than 7 mm.

When applied to a safety screen, the impact shall

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 10 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

neither result in damage to its mounting to the


extent that it is mechanically unsuitable for reuse,
nor shall tempered glass, if used, be cracked.

When applied to the face of a directly viewed


cathode ray tube, the impact shall not develop any
opening in the face of the tube. Scaling and
cracking of the glass is permissible. A cathode ray
tube that has been shown to comply with
CAN/CSA-C22.2 No. 228 or CAN/CSA-E61965
shall be considered acceptable with no further
tests.
12.3A.2 The impact specified in Clause 12.3A.1 shall be N/A
caused by allowing a solid, smooth, steel sphere
51 mm in diameter and weighing approximately 0.5
kg to strike the enclosure with the specified impact
in a direction perpendicular to the enclosure
surface. If deemed necessary, the enclosure shall
be tested with the proper cathode ray tube
mounted.
14.2.1 As an alternative, an isolating capacitor complying N/A
with the applicable requirements of CSA C22.2 No.
1 shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
14.2.2 As an alternative, an across-line capacitor N/A
complying with the applicable requirements of CSA
C22.2 No. 1 shall be acceptable.
14.5.1.2 As an alternative, a THERMAL LINK complying Pass
with CSA C22.2 No. 209 shall be acceptable.
14.5.2.1 As an alternative, a fuse-link complying with CSA Pass
C22.2 No. 248.14 shall be acceptable.
14.5.2.4 As an alternative, a Fuseholder assembly N/A
complying with CSA C22.2 No. 39 shall be
acceptable.
14.6.1 As an alternative, a TV-rated switch complying with N/A
CSA C22.2 No. 1 98, Cl 9, shall be acceptable.
14.6.2 As an alternative, a TV-rated switch complying with N/A
CSA C22.2 No. 1 98, Cl 9, shall be acceptable.
14.6.3 As an alternative, a TV-rated switch complying with N/A
CSA C22.2 No. 1 98, Cl 9, shall be acceptable.
14.6.4 As an alternative, a TV-rated switch complying with N/A
CSA C22.2 No. 1 98, Cl 9, shall be acceptable.
14.6.5 As an alternative, a TV-rated switch complying with N/A
CSA C22.2 No. 1 98, Cl 9, shall be acceptable.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 11 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

14.11 As an alternative, an optocoupler complying with Pass


CSA C22.2 No. 1 shall be acceptable.
14.12 As an alternative, a varistor complying with CSA Pass
C22.2 No. 1 shall be acceptable.
14.12A Gas discharge tubes complying with the following N/A
tests may be connected to bridge BASIC or
REINFORCED INSULATION. Ten samples of gas
discharge tubes isolating the ac supply from
exposed parts shall be subjected to the varistor
pulse tests of Clause 14.12. Following the pulses,
the device shall be allowed to return to room
temperature.

The dielectric breakdown voltage of the gas tube


shall not decrease by more than 50%, and the gas
discharge tube shall comply with the electric
strength test of Clause 10.3, with the test voltage
reduced to twice the mains voltage.
15.1.1 A receptacle provided for general purpose mains Pass
output shall comply with the requirements of CSA
Standard C22.2 No. 42 (dimensional requirements
are also specified in IEC 60906-2). The attachment
plug cap shall be of the polarized type when the
apparatus is provided with a manually operated,
MAINS connected single-pole switch for apparatus
on-off operation, a socket screwshell lampholder,
or a 15 or 20 A socket-outlet.
15.1.2 Banana plugs shall be acceptable. N/A
15.1.3 Replace the first paragraph with the following: N/A
Terminals and connectors used in output circuits of
supply apparatus, whose output voltage is not a
standard nominal mains voltage according to IEC
60038, Table 1, shall not be compatible with those
specified for household and similar general
purposes, for example those described in IEC
60083 [1], IEC 60320, IEC 60884, IEC 60906
(parts 1, 2, and 3), and CSA C22.2 No. 42.
15.2 Replace the third paragraph with the following: N/A
Earthing connections shall comply with the test
requirements of CSA C22.2 No. 0.4.
15.3.1A Equipment intended for permanent connection to N/A
the mains shall have provisions for connection to
the wiring system in accordance with the Canadian
Electrical Code, Part I.

The terminal parts and all other provisions for

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 12 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

permanent connection to fixed wiring shall comply


with CSA Standard CAN/CSA-C22.2 No. 0.
15.4.2 Mains plugs of non-permanently installed N/A
equipment shall comply with
a) CSA C22.2 No. 21 for moulded-on-type
attachment plugs; and
b) CSA C22.2 No. 42 for disassembly-type
attachment plugs (dimensional requirements are
also specified in IEC 60906-2).

Class II equipment provided with a general purpose


mains outlet, or a lampholder, shall be provided
with a polarized-type plug.

If the plug is a polarized type, single-pole switches


or overcurrent protectors shall not be connected in
the identified conductor.
16.1 Replace thie clause with the following: Pass
Flexible cord used for mains supply shall comply
with the requirements of CSA C22.2 No. 49. The
cord type shall be in accordance with Table 4 of
CSA C22.2 No. 1.

The attachment plug shall be rated not less than


125% of the apparatus rated current.

Cord sets shall comply with the requirements of


CSA C22.2 No. 21.

Non-detachable flexible cables and cords of Class I


apparatus shall be provided with a green/yellow
core connected to the protective earthing terminal
of the apparatus and, if a plug is provided, to the
protective earthing contact of the plug.

Compliance is checked by inspection.

Note: The colour of cores of flexible mains cords is


contained in IEC 60173 [4].
17.9A Adhesive securement and conductive coatings N/A
17.9A.1 The following parts, the displacement of which may N/A
result in a fire or shock hazard, shall not be
secured solely by adhesive, unless the adhesive
system complies with the resistance to external
forces test of Clause 9.1.7, the bump test of Clause
12.1.1, and the impact test of Clause 12.1.3, after
conditioning in accordance with Clause 17.9A.2:

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 13 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

a) internal metal parts/conductive coatings;


b) barriers; and
c) required enclosure parts.

Note: Cathode ray tubes are excluded from this


test.
17.9A.2 Adhesive and conductive coating securement N/A
conditioning
17.9A.2.1 Where required by Clause 17.9A.1, one sample of N/A
the apparatus or enclosure section shall be
conditioned in accordance with the requirements of
Clause 17.9A.2.2. Equivalent aging test data
supplied by the manufacturer may be considered in
lieu of ageing.
17.9A.2.2 Day 1: Place sample in oven at 100 ± 1°C for 1 N/A
week, or 82 ± 1°C for 8 weeks, at the
manufacturer's option.
Day 8 or day 57:
1. Remove from oven and leave at room
temperature for 1 h.
2. Place in freezer at -35 °C for 2 h.
3. Remove from freezer and allow to reach room
temperature overnight.
Day 9 or day 58:
1. Place in a compartment at 96% relative humidity
for 3 h.
2. Remove and leave at room temperature and
humidity for 1 h.
3. Place in oven at a temperature selected in the
first cycle for 3 h.
4. Remove and allow to come to room temperature
overnight.
Day 10 or day 59:
1. Place in freezer at -35°C for 2 h.
2. Remove and leave at room temperature for 1 h.
3. Place in humidity chamber at 96% relative
humidity for 3 h.
4. Remove and allow to come to room temperature
overnight.
Day 11 or day 60:
1. Place in oven at the temperature selected in the
first cycle for 3 h.
2. Remove for 1 h.
3. Place in freezer at -35°C for 2 h.
4. Remove and allow to come to room temperature
overnight.
Day 12 or day 61:

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 14 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

1. Place in humidity chamber at 96% relative


humidity for 3 h.
2. Remove and perform mechanical tests as
required by Clause 17.9A.1 as applicable.
18.1A A picture tube with a maximum face dimensions N/A
exceeding 75 mm either shall be intrinsically
protected with respect to effects of implosion and to
mechanical impact, in accordance with CAN/CSA-
C22.2 No. 228 or CAN/CSA-E61965, or the
enclosure of the apparatus shall provide adequate
protection against the effects of an implosion of the
tube (see Clause 12).
19 Third dashed paragraph: Replace "excluding" with Pass
"including"
19 Apparatus not tested because it is intended to be N/A
fastened in place shall be provided with the
following warning, marked on the apparatus or on a
durable label attached to the mains cord:
"WARNING: This apparatus must be securely
attached to the floor/wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury/death."
20.2.1A Enclosures of apparatus containing high-voltage or N/A
projection lamps shall have a minimum flammability
rating of category FV 1 according to IEC 60707 at
the minimum thickness used.
B Replace the annex with the following: N/A
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall comply
with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 15 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Denmark - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


2.6.1 The following is added: N/A
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
15.1.1 To the first paragraph the following is added: Pass
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.

Appliances of CLASS I provided with socket-outlets


with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
15.1.1 To the second paragraph the following is added: No socket outlets provided. N/A
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet
DKA1-4a. Other current ratings socket outlets shall
be in compliance with the Heavy Current
Regulation, Section 107-2-D1, Standard Sheet
DKA 1-3a or DKA 1-3b.
15.1.1 To the third paragraph the following is added: N/A
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 16 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Finland - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


5.4 To the end of 5.4 the following is added: N/A
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text shall be as follows: "Laite on
liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
B (IEC 62151, clause 4.1.1) N/A
Add after the first paragraph:
NOTE - CLASS I equipment which is intended for
connection to the building installation via a non-
industrial plug or a non-industrial appliance
coupler, or both, and in addition is intended for
connection to other equipment or a network, shall,
if safety relies on connection to protective earth or
if surge suppressors are connected between the
network terminals and ACCESSIBLE parts, has a
marking stating that the equipment must be
connected to an earthed mains socket-outlet. The
marking is as follows: "Laite on liitettava
suojamaadoituskoskettimilla varustettuun
pistorasiaan".
B (IEC 62151, clause 5.3.1) N/A
Add after the first test specifications paragraph:
NOTE 1: There are additional requirements for the
insulation.
Renumber the existing note as NOTE 2.
Add between the first and second paragraph: If this
insulation is solid, including insulation forming part
of a component, it shall consist at least of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 17 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

insulation consisting of an insulating compound


completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the compliance clause below and
in addition:
- passes the test and inspection criteria of 13.6 with
an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5 kV
(for performance of the test see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN
132400:1994 may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
132400, which in addition to the Y3 testing, is
tested with an impulse test of 2.5 kV defined in IEC
62151, subclause 6.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 132400;
- the impulse test of 2.5 kV is to be performed
before the endurance test in EN 132400 in the
sequence of tests as described in EN 132400.
B (IEC 62151, clause 5.3.2) N/A
Add after the fourth dash:
NOTE - Exclusions are applicable for equipment
that is intended for connection to the building
installation wiring using screw terminals or other
reliable means, and for equipment that is intended
for connection to the building installation wiring via
an industrial plug and socket-outlet or an appliance
coupler, or both, complying with IEC 60309 or with
a comparable national standard.

Germany - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


6.1 For the operation of any cathode ray tube intended N/A
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 18 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Group - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


3.1 Add the following indent at the end of the list: N/A
- exposure to excessive sound pressures from
headphones or earphones.

NOTE A new method of measurement is described


in EN 50332-1, Sound system equipment:
Headphones and earphones associated with
portable audio equipment - Maximum sound
pressure level measurement methodology and limit
considerations - Part 1: General method for "one
package equipment", and in EN 50332-2, Sound
system equipment: Headphones and earphones
associated with portable audio equipment -
Maximum sound pressure level measurement
methodology and limit considerations - Part 2:
Guidelines to associate sets with headphones
coming from different manufacturers.
4.1.1 Replace the text of the note by: Pass
NOTE For ROUTINE TEST reference is made to
EN 50333.
5.1i Add the following note: Pass
NOTE - For RATED POWER CONSUMPTION
measurements of TVs reference is made to EN
62087. Measurements are done in the ON (play)
operating mode.
5.4.1 Add the following indent: N/A
za) For a portable sound system, a warning that
excessive sound pressure from earphones and
headphones can cause hearing loss.
6.1 Replace the entire subclause by: N/A
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions. Compliance is checked by
measurement under the following conditions:

In addition to the normal operating conditions, all


controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 19 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

NOTE 1 Soldered joints and paint lockings are


examples of adequate locking.

The dose-rate is determined by means+ of a


radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus. Moreover, the measurement shall be
made under fault conditions causing an increase of
the high-voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made. The dose-rate shall not
exceed 1μSv/h (0,1 mR/h) taking account of the
background level.

NOTE 2 These values appear in Directive


96/29/Euratom of 13th May 1996.

A picture is considered to be intelligible if the


following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
13.3.1 Delete note 4. Pass
14 Delete note 4 and note 5. Pass
15.1.1 Delete note 1 and note 2. Pass
15.2 Delete note 2. Pass
16.1 Delete note 1. Pass
16.2 Delete the note. Pass
20 Delete note 2. Pass
B Replace note 1 by: N/A
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
G Delete the note. Pass
J.2 Delete the notes of Table J.1. Pass
N Add after the introduction: Pass
For ROUTINE TEST reference is made to EN
50333.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 20 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Z1 Resistance to candle flame ignition N/A

A television set shall be so designed that the


likelihood of ignition and the spread of fire caused
by a candle flame is reduced.

NOTE 1 An apparatus with a viewing screen is not


regarded to be a television set if it is declared not
to be so by the manufacturer.

This requirement does not apply to the display


screen of rear projection TV’s.

NOTE 2 This exemption has been allowed because


this technology is falling out of use and it is
expected that within a few years it will no longer
exist. This exemption will not be extended to other
technologies.

NOTE 3 The frame around the screen is not


exempted from the requirements.

Wood and WOOD-BASED MATERIAL with a


thickness of at least 6 mm is considered to fulfil the
V-1 requirement when applying CLC/TS 62441.
Compliance is checked according to CLC/TS
62441.

NOTE 4 The term vertical, as used in the first dash


of clause 5.2 of CLC/TS 62441, does not mean a
perfectly vertical position. It should be interpreted
as any surface that can be touched by the flame of
a candle of 150 mm height and 20 mm diameter
while the candle is still touching the supporting
surface. A typical candle used in the home is
assumed to be 20 mm diameter.

NOTE 5 It is expected that CLC/TS 62441 will in


the future be replaced by a standard, at which time
that standard will become applicable, subject to a
vote by National Committees at the time.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 21 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Italy - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


5.1 The following requirements shall be fulfilled: N/A
- The power consumption in Watts (W) shall be
indicated on TV receivers and in their instruction for
use (Measurement according to EN 60555-2)
NOTE EN 60555-2 has since been replaced by IEC
60107-1:1997.
- TV receivers shall be provided with an instruction
for use, schematic diagrams and adjustments
procedure in Italian language.
- Marking for controls and terminals shall be in
Italian language. Abbreviation and international
symbols are allowed provided that they are
explained in the instruction for use.
- The ECC manufacturers are bound to issue a
conformity declaration according to the above
requirements in the instruction manual. The correct
statement for conformity to be written in the
instruction manual, shall be: Questo apparecchio è
fabbricato nella CEE nel rispetto delle disposizioni
del D.M. marzo 1992 ed è in particolare conforme
alle prescrizioni dell'art. 1 dello stesso D.M.
- The first importers of TV receivers manufactured
outside EEC are bound to submit the TV receivers
for previous conformity certification to the Italian
Post Ministry (PP.TT).

The TV receivers shall have on the back cover the


certification number in the following form:
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT
S for stereo
T for teletext
pT for retrofitable teletext

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 22 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Japan - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


1.1.3 Add the following as a NOTE after the first Pass
sentence:
NOTE 1 - In Japan, the requirements for regions
with moderate apply.
2.4.9 In NOTE 1, replace: N/A
"see 4.2.2 of IEC 62151" by "see 4.2.2 of IEC
62151 [27]"
2.6.2A Add this subclause: N/A
CLASS 0I EQUIPMENT: Equipment which has, as
for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the protective
earthing conductor in the building wiring those
conductive parts that are otherwise capable of
assuming HAZARDOUS VOLTAGES if the BASIC
INSULATION fails, and
- using a supply cord without earthing conductor
and a plug without earthing wire although the
equipment has externally an earth terminal or a
lead wire for earthing.
Equipment provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin-tow pin adaptor is also regarded as Class
0I.
NOTE: Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
3.2 Add the "Class 0I equipment" in the first sentence N/A
of this sub-clause
3.2 Add the following after the first sentence of this N/A
sub-clause:
NOTE: Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment
4.2.8 Delete this clause N/A
4.3.4b Replace: N/A
"IEC 60730-1" by "JIS C 9730-1" (corresponding to
IEC 60730-1)
4.3.12 Delete this clause N/A
4.3.13 Replace: Pass
"250 V a.c." by "the maximum of the variable
range"
5.4.2A Addition: N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 23 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

For CLASS 0I EQUIPMENT, the following


instruction shall be indicated in Japanese where
readily visible on the mains plug or the product:
"WARNING: Provide an earthing connection"
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated in Japanese
where readily visible on the product or written in the
operating instructions:
"WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains."
6.2 In NOTE 1, replace "IEC 61040 [10]" by "JIS C N/A
6181:1995 [10]"
7.1.5 Add the words: Pass
"without dimensions restrictions" after the figure,
"65 K" in the first sentence of Condition "b" in Table
3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating condition
7.1.5 Add the following paragraph as 2nd paragraph of Pass
Condition "d" in Table 3:
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material. Permissible
temperature rise of "Supply cords and wiring
insulation" is applicable only to the materials used
in supply cords complying with JIS C 3662
(corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245). Materials used in
other wiring shall comply with item 3 of detailed
regulations, 1.(1).b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material.
7.1.5 In the first paragraph of Condition "f" of Table 3, Pass
add "JIS K 7206:1999 or" before the reference, ISO
306
7.1.5 In Condition "f", 1) of Table 3, add "JIS K Pass
7206:1999 or" before the reference, ISO 306

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 24 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

7.2 In NOTE 2, add "or JIS standard" after the words Pass
"IEC Standard"
8.5 In the first paragraph, add "and Class 0I N/A
Equipment" after the words "Class I Equipment"
8.5 In the sixth paragraph (before NOTE 3), add the N/A
following to the end of the first sentence:
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal in the external where
easily visible or a protective external earth wire
from mains plug.
8.11 In NOTE 2, c), add "or JIS C 2107, JIS C 2336, JIS Pass
C 2338" after the reference "IEC 60454"
9.1.1.1 In the last paragraph, add the following sentence N/A
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA
10 In NOTE, replace "IEC 60664-1 and IEC 60664-4 Pass
[9]" by "JIS C 0664:2003 and IEC/TR3 60664-4 [8]"
10.1 Add "CLASS 0I EQUIPMENT and" to the head of N/A
the first paragraph.
10.3.2 Addition: In Table 5, add the following values to the Pass
sub-table of NOTE:
Operating Voltage U(peak) Curve A Curve B
142 V 1414 V 2828 V
11.2.1 Add the following after the original NOTE: N/A
NOTE 2: The fuse except operating characteristics
specified in IEC 60127 shall be tested in
consideration of the characteristic.
11.2.3 Add "and CLASS 0I" after the words "CLASS I" N/A
13.4 In NOTE 2 of Table 11, replace "IEC 60664-1" by Pass
"JIS C 0664:2003" (corresponding to IEC 60664-1)
14.3.3.2 in the second sentence of the first paragraph, add Pass
"or JIS C 2107, JIS C 2336 and JIS C 2338" after
the reference "IEC 60454"
14.5.1.1 In item a), add "JIS C 9730 series or" before the Pass
reference "IEC 60730 series"
14.5.1.2 In item a), replace "IEC 60691" by "IEC 60691 or Pass
JIS C 6691:2003"
14.5.1.2 In the first paragraph of item a), add "or Appendix 3 Pass
of the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material" after the reference to the last of the
sentence.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 25 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

14.5.2.1 Replace: Pass


"IEC 60127" by "IEC 60127 or JIS C 6575"
14.5.2.1 In the first paragraph, add "Appendix 3 of the Pass
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material (limited to Fuses with the rated current of 1
A or more), or" after the words "shall comply with"
14.5.2.2 Add the following paragraph before the last Pass
paragraph:
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, only the rated current needs to be
marked.
14.5.3 Replace "IEC 60730-1" by "JIS C 9730-1" N/A
(corresponding to IEC 60730-1)
14.5.4 Replace "IEC 60127" by "IEC 60127 or JIS C Pass
6575"
14.6.1 Add the following paragraph after NOTE: Pass
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below
- the controlling current exceeds 0.2 A r.m.s a.c. or
d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
14.6.1 In item a), replace "IEC 61058-1" by "IEC 61058-1 Pass
or JIS C 4526-1:1999"
14.6.2 Replace "IEC 61058-1" by "IEC 61058-1 or JIS C N/A
4526-1:1999"
14.6.3 Replace "IEC 61058-1" by "IEC 61058-1 or JIS C N/A
4526-1:1999"
14.6.5 Replace "IEC 61058-1" by "IEC 61058-1 or JIS C N/A
4526-1:1999"
14.7 Replace "IEC 60950" by "JIS C 6950:2006" N/A
15.1.1 Replace the first and second paragraph with by the Pass
following:
Plugs and appliance couplers for the connection of
the apparatus to the MAINS and socket-outlets and
interconnection couplers shall comply with the
relevant JIS standards. If there is no appropriate
JIS standard, they shall comply with the relevant
IEC standards.
Appliance connectors, interconnection outlets and

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 26 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

interconnection plug-connectors compiled with


Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material are accepted. In that case,
if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with dimensions
and ratings specified in the relevant standard
sheets of IEC 60320-1.
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article 2
(corresponding to IEC 60884) of the Ordinance.
- Appliance couplers: Appendix 4 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article 2
(corresponding to IEC 60320-1) of the Ordinance.
- Appliance inlets: IEC 60320-1
- Interconnection outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. IEC
60320-2-2.
- Interconnection couplers: Appendix 4 of Article 1
of the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance.
Delete NOTE 1 and NOTE 2.
15.1.1 Replace the paragraph after NOTE 2 by the Pass
following:
MAINS socket-outlets and interconnection couplers
mounted on CLASS 0I and CLASS II apparatus
shall not permit connection of CLASS I apparatus.
15.1.1 Replace the paragraph before NOTE 3 by the N/A
following:
MAINS socket-outlets and interconnection couplers
mounted on CLASS I apparatus shall be provided
with protective earthing contacts which are reliably
connected to the PROTECTIVE EARTHING
TERMINAL or contact of the apparatus. If not, it
shall not permit connection of CLASS I apparatus.
15.1.1 Replace NOTE 4 by the following: N/A
Socket-outlets not allowing the connection of
CLASS I apparatus can be designed, for instance,
similar to IEC 60906-1, standard sheets 3-1 or 3-2,
or according to IEC 60320-2-2, standard sheets D
or H.
15.1.2 Delete the following sentence in NOTE: N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 27 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

"An example of a connector not meeting the


requirements of this sub clause is the so-called
"banana" plug."
15.1.3 Replace the references "IEC 60083 [1], IEC 60320, N/A
IEC 60884, IEC 60906" by "JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906"
15.2 Add "and CLASS 0I EQUIPMENT" after the words N/A
"CLASS I EQUIPMENT"
15.2 Add the following paragraph after the first N/A
paragraph:
The external earth wire of plug with an external
earth wire shall not be earthed by a clip. Rated
voltage of plug with an protective external earth
wire shall be less 150 Vac.
15.2 Delete the following paragraph: N/A
In supply apparatus of Class I with non-hazardous
live output voltage, output circuits shall not be
connected to the protective earthing conductor.
15.3.1 In the first paragraph, replace "IEC 60998-2-2" by N/A
"IEC 60998-2-2 or JIS C 2814-2-2:2001"
15.3.1 In the first paragraph, replace "IEC 60999" by "IEC N/A
60999-1"
15.3.1 In the first paragraph, replace "IEC 60335-1" by N/A
"JIS C 9335-1:2003 (corresponding to IEC 60335-
1)."
15.3.3 Replace "ISO 261 or ISO 262" by "JIS B 0205- N/A
2:2001 or JIS B 0205-3:2001"
15.3.5 In the second paragraph, replace "IEC 60950" by N/A
"JIS C 6950:2006"
15.3.5 Replace Table 15 by the following: N/A
RATED CURRENT CONSUMPTION Nominal
cross-sectional area,
of the apparatus (a) mm2
Up to and including 6 0.75 to 1
Over 6 up to and including 10 1 to 1.5
Over 10 up to and including 16 1.5 to 2.5

(a) The RATED CURRENT CONSUMPTION


includes currents which can be drawn from socket-
outlets providing MAINS power for other apparatus.
15.3.9 Add the following to the last of the first paragraph: N/A
This does not apply to CLASS 0I EQUIPMENT with
a protection earthing terminal separately.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 28 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

15.4.1 In NOTE 1, replace "IEC 60884-1" by "JIS C 8282 N/A


(corresponding to IEC 60884-1)"
15.4.1 In NOTE 2, replace "IEC 60083 [1]" by "JIS C N/A
8303"
15.4.2 In NOTE, replace "IEC 60083 [1]" by "JIS C N/A
8303:1993 [1]"
15.4.3 Add the following NOTE to Table 17: N/A
If mains plug is parallel blade, a pull force as given
in "Over 10 A up to and including 16 A, 130/250 V"
of Table 17 is applied.
16.1 Add the following to the end of first paragraph: Pass
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance.
16.1 Delete NOTE 1. Pass
16.1 Replace the second paragraph by the following: Pass
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
16.1 Replace "IEC 60227" by "JIS C 3662 Pass
(corresponding to IEC 60227)"
16.1 Replace "IEC 60245" by "JIS C 3663 Pass
(corresponding to IEC 60245)"
16.1 Add the following paragraph after the third N/A
paragraph:
An external earth wire of Class 0I equipment shall
be green/yellow, and the length of the earth wire
from the plug shall be equal or more than 10 cm.
16.2 Replace the first paragraph by the following: Pass
Power supply cord conductors complied with JIS C
3662 (corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245) shall have a nominal
cross-sectional area not less than those shown in
table 18. If power supply cord conductors comply
with other standards, it shall comply with relevant
wiring requirements.
16.2 Replace Table 18 by the following: Pass
RATED CURRENT CONSUMPTION Nominal
cross-sectional area,
of the apparatus (a) mm2

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 29 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Up to and including 6 0.75


Over 6 up to and including 10 1
Over 10 up to and including 16 1.5

(a) The RATED CURRENT CONSUMPTION


includes currents which can be drawn from socket-
outlets providing MAINS power for other apparatus.
16.3 In item a), replace "IEC 60885-1" by "JIS C 3661- Pass
1:1998"
16.3 In item b), replace "IEC 60227-2" by "JIS C 3662-2 Pass
(corresponding to IEC 60227-2)"
16.5 Add “or CLASS 0I EQUIPMENT used a plug with N/A
an external earth wire” after the words "CLASS I
EQUIPMENT"
20.1.2 In NOTE, replace "ISO 1043-1 [19]" by "JIS K Pass
6899-1:2000 [19]"
B Replace "Normative" by "Informative" N/A
G Replace "IEC 60707" by "JIS C 0066:2001" Pass
Replace "IEC 60695-2-2" by "JIS C 60695-2-
2:2000"
Replace "IEC 60695-11-10" by "JIS Z 2391:1999"

Korea - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


5.101 Other Marking: Wording or an information N/A
regulated in IEC Publication 417 giving high
voltage warning to layman shall be marked, if
apparatus contains a part more than 600 V.
15.1.1 Plugs for the connection of the apparatus to the N/A
supply mains and socket outlets for providing
mains power to other apparatus shall comply with
the Korean requirement (KSC8300 and KSC8305).
31 Radio frequency interference - The apparatus shall N/A
comply with the relevant CISPR requirements
(EMC=EMI+EMS)

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 30 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Malaysia - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


3.2 Class 0 and 01 appliances are not allowed N/A
4.2.1 The supply voltage in Malaysia is 240 Vac, 50 Hz. Pass
15.1.1 13 A fused mains plug shall comply to Malaysian N/A
standard (MS 589:Part1), if applicable
15.1.1 2-pin plug tops shall comply to Malaysian standard Pass
(MS 1578:2003), if applicable

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 31 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Norway - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


5.4 To the end of 5.4 the following is added: N/A
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text shall be as follows: "Apparatet må
tilkoples jordet stikkontakt"
5.4.1 To the end of 5.4.1 (after the compliance N/A
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
"Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)"

NOTE In Norway, due to regulation for installations


of cable distribution systems, and in Sweden, a
galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 32 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

for 1 min.

Translation to Norwegian (the Swedish text will


also be accepted in Norway):
"Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr og er
tilkoplet et kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret
til kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel-TV nettet."

Translation to Swedish:
"Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medfőra risk főr brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet."
13.3.1 To the second paragraph the following is added: Pass
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
15.1.1 Mains socket-outlets mounted on CLASS II N/A
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with the
following amendments:
- 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
- 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065.
Also the protecting rim shall be tested.
B (IEC 62151, clause 4.1.1) N/A
Add after the first paragraph:
NOTE - In Norway, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both, and in addition is
intended for connection to other equipment or a
network, shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 33 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

ACCESSIBLE parts, have a marking stating that


the equipment must be connected to an earthed
mains socket-outlet. The marking text shall be as
follows: "Apparatet skal tilkoples jordet stikkontakt".
B (IEC 62151, clause 4.1.4) N/A
Add at the end of the subclause:
NOTE: For requirements see 4.1.1, note and 5.3.1,
note 1.
B (IEC 62151, clause 4.2.1.2) N/A
Add at the end of the subclause:
NOTE: For requirements see 5.3.1, note 1.
B (IEC 62151, clause 4.2.1.3) N/A
Add at the end of the subclause:
For requirements see 4.1.1, note and 5.3.1, note 1.
B (IEC 62151, clause 4.2.1.4) N/A
Number the existing note as NOTE 1 and add at
the end of the subclause:
NOTE 2: For requirements see 4.1.1, note and
5.3.1, note 1.
B (IEC 62151, clause 5.3.1) N/A
Add after the first test specifications paragraph:
NOTE 1: There are additional requirements for the
insulation.
Renumber the existing note as NOTE 2.
Add between the first and second paragraph: If this
insulation is solid, including insulation forming part
of a component, it shall consist at least of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the compliance clause below and
in addition:
- passes the test and inspection criteria of 13.6 with
an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5 kV

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 34 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

(for performance of the test see N.2.1).


It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993 may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by IEC
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2.5 kV defined in IEC
62151, subclause 6.2.1;
- the additional testing shall be performed on all the
test specimens as described in IEC 60384-14;
- the impulse test of 2.5 kV is to be performed
before the endurance test in IEC 60384-14 in the
sequence of tests as described in IEC 60384-14.
B (IEC 62151, clause 5.3.2) N/A
Add after the fourth dash:
NOTE - In Norway, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals or
other reliable means, and for equipment which is
intended for connection to the building installation
wiring via an industrial plug and socket-outlet or an
appliance coupler, or both, complying with IEC
60309 or with a comparable national standard.
J.2 After Table J.1 the following is added: N/A
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 35 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Sweden - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


5.4 To the end of 5.4 the following is added: N/A
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text shall be as follows: "Apparaten
skall anslutas till jordat uttag"
5.4.1 To the end of 5.4.1 (after the compliance N/A
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
"Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)"

NOTE In Norway, due to regulation for installations


of cable distribution systems, and in Sweden, a
galvanic isolator shall provide electrical insulation
below 5 MHz. The insulation shall withstand a
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 36 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

for 1 min.

Translation to Norwegian (the Swedish text will


also be accepted in Norway):
"Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr og er
tilkoplet et kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret
til kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel-TV nettet."

Translation to Swedish:
"Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medfőra risk főr brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet."
14 Switches containing mercury such as thermostats, Pass
relays, and level controllers are not permitted.
B (IEC 62151:2000, clause 4.1.1) N/A
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both, and in addition is
intended for connection to other equipment or a
network, shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket-outlet. The marking text shall be as
follows: "Apparaten skall anslutas till jordat uttag".
B (IEC 62151, clause 5.3.1) N/A
Add after the first test specifications paragraph:
NOTE 1: There are additional requirements for the
insulation.
Renumber the existing note as NOTE 2.
Add between the first and second paragraph: If this
insulation is solid, including insulation forming part
of a component, it shall consist at least of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 37 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

strength test below.


If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the compliance clause below and
in addition:
- passes the test and inspection criteria of 13.6 with
an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5 kV
(for performance of the test see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 60384-
14:1993 may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by IEC
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2.5 kV defined in IEC
62151, subclause 6.2.1;
- the additional testing shall be performed on all the
test specimens as described in IEC 60384-14;
- the impulse test of 2.5 kV is to be performed
before the endurance test in IEC 60384-14 in the
sequence of tests as described in IEC 60384-14.
B (IEC 62151, clause 5.3.2) N/A
Add after the fourth dash:
NOTE - In Sweden, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals or
other reliable means, and for equipment which is
intended for connection to the building installation
wiring via an industrial plug and socket-outlet or an
appliance coupler, or both, complying with IEC
60309 or with a comparable national standard.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 38 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Switzerland - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


21 Ordinance on environmentally hazardous Pass
substances SR 814.081, Annex 1.7,
Mercury - Annex 1.7 of SR 814.81 applies for
mercury.
Switches containing mercury such as thermostats,
relays and level controllers are not allowed.

Ordinance on chemical hazardous risk reduction


SR 814.81, Annex 2.15
Batteries
Annex 2.15 of SR 814.81 applies for batteries
containing cadmium and mercury.
Note: Ordinance relating to environmentally
hazardous substances, SR 814.013of 1986-06-09
is not longer in force and superseded by SR 814.81
of 2009-02-01 (ChemRRV).
24 Supply cords of portable electrical appliances N/A
having a rated current not exceeding 10 A shall be
provided with a plug complying with IEC 60884-1
(3.ed.) + am1, SEV 1011 and one of the following
dimension sheets:
- SEV 6532-2.1991 Plug Type 15 3P + N + PE,
250/400V, 10A
- SEV 6533-2.1991 Plug Type 11 L + N, 250V, 10A
- SEV 6534-2.1991 Plug Type 12 L + N + PE,
250V, 10A
24 Supply cords of portable electrical appliances N/A
having a rated current not exceeding 16 A shall be
provided with a plug complying with IEC 60884-1
(3.ed.) + am1, SEV 1011 and one of the following
dimension sheets:
- SEV 5932-2.1998 Plug Type 25 3P + N + PE,
250/400V, 16A
- SEV 5933-2.1998 Plug Type 21 L + N, 250 V,
16A
- SEV 5934-2.1998 Plug Type 23 L + N + PE, 250
V, 16A
NOTE 16 A plugs are not often used in Swiss
domestic installation system

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 39 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

United Kingdom - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


15.1.1 Apparatus which is fitted with a flexible cable or N/A
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with a
"standard plug" in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.

NOTE "Standard plug" is defined in SI 1768:1994


and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 40 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

United States - Differences to IEC 60065:2001 + Amd 1:2005 / EN 60065:2002


1.1.1 This standard covers apparatus intended for Pass
household, commercial, and professional use
1.1.1 Delete reference to Annex L: Electronic flash N/A
apparatus for photographic purposes. Replace
with reference to UL 122.
1.1.1 Mains connected apparatus is designed to allow Pass
installation in accordance with the National
Electrical Code, ANSI/NFPA 70.
1.1.3 Apparatus intended for outdoor use comply with N/A
the additional requirements of Annex A
1.1.5 Some equipment covered by these requirements N/A
may also be required to comply with applicable
requirements in other appropriate standards
4.2.1 The rated supply voltage for single phase Pass
apparatus was assumed to be 120V or 120/240V
4.2.4 a) Minimum audio output is not less than 0.5 W per Pass
channel unless the maximum audio output is less
than 0.5 W per channel
4.2.4.1 An apparatus with multiple modes of operation, Pass
multiple signal input sources, or both, is operated
using each mode of operation or signal input
source separately, or in combination, according to
the manufacturer's instructions to produce the
maximum power input
4.2.11 Table 2 - External supply sources are assumed to N/A
be capable of delivering 30 A, unless otherwise
specified (for no-load voltage and internal
resistance values per UL 60065)
4.3.4 As an option, PTC thermistors may instead comply N/A
with UL 1434.
5 As an alternate, a reagent grade hexane with a Pass
minimum of 85% as n-hexane may be utilized
5 Test for conductive labels secured in place by N/A
adhesive
5.1 Component power supplies and adapters N/A
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL60950, or UL 60950-1 are considered to fulfill
the test requirements of items "a" through "i" of this
clause.
5.1f Rated frequency marking Pass

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 41 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

5.1j "Date of Manufacture" marking on all apparatus Pass


5.1k Multiple Manufacturing Location Identification Pass
5.1l Combination of two graphical symbols and Pass
supplementary marking (figure 19) and/or the
single graphical symbol (figure 20)
5.1m Equipment rack marking for audio/video systems N/A
5.1n Class I apparatus having touch current levels N/A
greater than 0.75 MIU and equal to or less than 3.5
MIU are provided with a cautionary statement
5.1o Add: The grille/ventilation areas of the top surface N/A
of an apparatus that are limited in temperature rise
in accordance with condition b of Table 3 are
provided with cautionary hot surface marking.
5.2c Output terminals are marked with voltage, N/A
frequency and current or power; output terminals
installed or interconnected in the field by a skilled
person are marked with the Class of wiring
5.2d Speaker terminal connections are marked "Class 1 N/A
Wiring", "Class 2 Wiring" or "Class 3 Wiring"
5.2d User instruction manual explains risks and proper N/A
connecting and insulating techniques when
connecting speakers
5.3 An explanation and illustration of safety related Pass
graphical symbols used on the apparatus are
included in the user instruction manual preceding
any operating instructions
5.3 All safety related graphic symbols visible during Pass
servicing by a skilled person are illustrated and
explained in the service manual
5.4 Important Safety Instructions are packed with each Pass
apparatus and shall be verbatim
5.4 Note 1 and 2 - Deleted Pass
5.4.1a The user instruction manual contains the Outdoor Pass
Use warning
5.4.1e Deleted Pass
5.4.1h Reference to IEC 61965 is replaced by UL 61965 N/A
5.4.3 When the user instruction manual contains N/A
instructions for use by service personnel, the
instructions are separate in format and preceded
by a cautionary statement
6.1 Compliance is checked in accordance with the N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 42 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

requirements in the U.S. Code of Federal


Regulations, Title 21, Chapter I, Sections 1010.2,
1010.3, and 1020.10 by measuring the radiation
produced by the apparatus employing a production
representative chassis
6.2 References to IEC 60825-1 are deleted Pass
6.2 Apparatus is classified and labeled according to the N/A
Code of Federal Regulations, Title 21, Chapter I,
Sections 1010.2, 1010.3, 1040.10 and 1040.11.
6.2.2 Deleted Pass
7 Table 3 - Temperature limits for various classes of Pass
insulation systems
7 Table 3 - Note a): Materials rated in accordance Pass
with UL 746B may be used at their rated higher
temperature
7 Table 3 - Note b): For grille/ventilation areas in the N/A
top surface directly above internal heatsinks, a
temperature rise up to 65 K is allowed. The
marking of 5.1(o) shall be provided on the top
surface adjacent to the grille/ventilation areas.
7 Table 3 - Note d): UL 1446 replaces reference to N/A
IEC 60085
7 Delete conditions h and i Pass
7.2 A UL 746B polymeric material temperature rating Pass
can be accepted in lieu of the softening
temperature test. The softening temperature test
need not be performed on materials used in UL
Listed or Recognized parts.
8.1 A metal part that is not inherently resistant to N/A
corrosion shall be properly protected against
corrosion
8.9.1 Sleeving, tape, tubing, and wire insulation are Pass
suitable for the conditions of use, such as voltage
and temperature, and comply with UL 224, UL 510,
or UL 1441, as applicable
8.10 Component power supplies and their internal N/A
insulation complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfill
the test requirements of the clause
8.17 As an option, winding wire insulation may instead N/A
comply with the requirements in UL 2353
8.19.1 An all-pole switch or circuit breaker is not required N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 43 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

to have contact separation of at least 3 mm


8.23 Printed wiring boards supporting circuits involving Pass
the risk of electric shock comply with the
requirements in UL 796.
9.1.1.1 Touch current limit for Class I apparatus is 3.5 MIU. N/A
9.1.1.1a 2nd dash: - for audio signals of professional and N/A
commercial apparatus, 120 V r.m.s.
9.1.1.1a 3rd dash: - for audio signals other than professional Pass
and commercial apparatus, 71 V r.m.s.
9.1.1.1b Touch current measurement is carried out in Pass
accordance with the American National Standard
for Leakage Current for Appliances, UL 101 and
does not exceed 0.5 MIU for Class II. Delete Note
2.
9.1.1.2 UL articulated finger used instead of the test probe Pass
B (IEC 61032) and application of Probes 18 and 19
of IEC 61032 is deleted
10.3 Table 5, Note 1: With respect to mains voltages in Pass
the range of 105-130 V (r.m.s.), the test voltages
are considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation.
11 Component power supplies and their power N/A
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, UL 60950, or UL 60950-1 are considered
to fulfill the test requirements on the clause.
11.1 The touch current limit for terminal contacts has N/A
been increased to twice the value given in 9.1.1.1.
11.2.1 Additional testing is not required if the temperature Pass
is limited by fuses
12 Component power supply adaptors and their N/A
enclosures complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, UL 60950, or UL 60950-1 are considered
to fulfill the test requirements on the clause.
12.1.3 Impact test using the spring operated impact Pass
hammer is deleted
12.1.3 Table 6 - Impact test criteria detailing impact Pass
location, impact energy and additional pass/fail
results
12.1.4 As an option, any number from one to three N/A
samples may instead be permitted to be used in

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 44 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

any combination that results in a total of three


drops
12.1.6 Handle strength test. When polymeric materials N/A
are involved, testing is to be conducted before and
after the sub-clause 12.1.5 stress relief test.
12.8 Test for enclosures, barriers, components and N/A
leads that rely on adhesive
13 Component power supplies and their power N/A
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, UL 60950, or UL 60950-1 are considered
to fulfill the test requirements on the clause.
13.4 Material group is verified according to UL 746A CTI Pass
testing data. References to IEC 60112 are deleted.
13.5.1 UL 796 replaces reference to IEC 60249-2 Pass
13.5.1 UL 746C replaces reference to IEC 60664-3 Pass
13.5.2 Coated printed wiring boards comply with Pass
applicable requirements in UL 746C
14 Note 2 has been deleted Pass
14 Components not covered by Clause 14 comply with Pass
the applicable requirements for that component.
Annex Y provides a list of requirements for
components.
14.1 Component power supplies and their resistors N/A
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfill
the test requirements of this clause
14.2 Component power supplies and their capacitors N/A
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfill
the test requirements on the clause.
14.2.1 As an option, a component such as a capacitor, a Pass
combination capacitor and resistor, or a suppressor
may instead comply with UL 1414.
14.2.2 As an option, a component such as a capacitor, a Pass
combination capacitor and resistor, or a varistor, or
a suppressor may instead comply with UL 1414.
14.2.4 Components subjected to the requirements in N/A
14.2.1 and 14.2.2 shall additionally comply with
the enclosure requirements of UL 1414.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 45 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

14.3 Component power supplies and their inductors and N/A


windings complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfill
the test requirements on the clause.
14.4 High voltage materials are rated V-2 minimum and N/A
comply with either 14.4.1 or 14.4.3
14.4 High voltage isolating components comply with N/A
14.4.4
14.4.1 High Voltage arcing test replaces existing High N/A
Voltage Transformers and Multipliers test
14.4.2 Deleted Pass
14.4.3 High voltage component part flame test N/A
14.4.4 High voltage isolating component test N/A
14.5.1.1 Thermal cut-outs comply with UL 873 or UL 60730- N/A
2-9. References to the IEC 60730 series of
standards have been deleted.
14.5.1.1a Deleted Pass
14.5.1.1b Deleted Pass
14.5.1.2 Thermal links comply with UL 60691 Pass
14.5.1.2a Deleted Pass
14.5.1.2b Deleted Pass
14.5.1.3 Deleted Pass
14.5.2.1 Fuse links shall comply with UL 248-14. Pass
References to IEC 60127 have been deleted.
14.5.2.2 The current and voltage rating for each fuse-link is Pass
located on each fuseholder or close to the fuse-
link. Pre-arcing time/current characteristic and
breaking capacity marking requirements have been
deleted. References to IEC 60127 have been
deleted.
14.5.2.2 Fuse link markings are not required for apparatus N/A
having permanently sealed enclosures
14.5.3 As an option, a PTC thermistor complies with N/A
requirements of UL 1434
14.5.3 Third and fourth paragraphs - Deleted Pass
14.5.3a Other protective devices directly connected to the N/A
mains have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL 2111
14.5.4 Reference to fuse-links not standardized in IEC N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 46 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

60127 is deleted
14.6.1 Switches and relays comply with UL 1054, UL N/A
61058-1 or UL 508
14.6.1 Mains switch or relay are rated for the total rated N/A
current consumption of the apparatus
14.6.1 A rating of a mains switch or relay, provided on an N/A
audio apparatus intended for commercial use, is
equal to or greater than the maximum steady state
current it controls under normal operating
conditions, except the audio output is adjusted to
1/3 maximum undistorted output or at 1/3 of the
rated output power, whichever is greater
14.6.1a Deleted N/A
14.6.1b Deleted N/A
14.6.2 Deleted N/A
14.6.3 Deleted N/A
14.6.4 Deleted Pass
14.6.5 A switch or relay that controls a mains socket-outlet N/A
shall have a rating equal to the rated current
consumption of the apparatus plus the current
rating of the socket-outlet. References to IEC
61058-1 have been deleted.
14.6.6 Mains switch provided on audio apparatus intended N/A
for household use and on all video apparatus
complies with 14.6.6(a), (b) or (c)
14.6.6 A switch that controls a mains connected socket- N/A
outlet complies with 14.6.6(b)
14.6.6 The contacts of a mains relay complies with N/A
14.6.6(a), (b) or (d)
14.6.6 The contacts of a mains relay that controls a mains N/A
socket-outlet complies with 14.6.6(b) or (d)
14.6.6a Switch or relay contacts have current rating equal N/A
to or greater than 1.414 times the inrush current of
the apparatus
14.6.6b Switch or relay is TV rated N/A
14.6.6c Switch is located on the back of apparatus and is N/A
not operable from a remote control
14.6.6d Relay is to be subjected to the 14.6.6.2 endurance N/A
test
14.6.6.1 Peak inrush current test N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 47 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

14.6.6.2 Relay endurance test N/A


14.6.7 Current, frequency and voltage rating for each pole N/A
of a double pole switch controlling two different
circuits
14.6.7 Double-pole switch controlling one ac circuit and N/A
one dc circuit
14.7 Use of the jointed test finger in Figure 18 to N/A
determine accessibility (IEC 60950, 2.8.2) and
interlock operation (IEC 60950, 2.8.3)
14.10.1 Internal rechargeable and non-rechargeable N/A
batteries that are replaceable by the user or skilled
person shall additionally comply with 14.10.2 -
14.10.5
14.10.1 Test requirements from UL 2054 for special battery N/A
packs that are removable by the user from the
apparatus and may be carried separately from the
apparatus - Short circuit test, Abnormal charging
test, Forced-discharge test, and 250-N steady force
test
14.10.1 Note: Consumer grade, non-rechargeable carbon- N/A
zinc or alkaline batteries are not subjected to the
tests specified in Clauses 14.10.2-14.10.5
14.10.5 As an option, the Battery Drop test may instead be N/A
conducted on one sample that was subjected to
three drops.
14.10.6 Location of overcurrent protective device for N/A
apparatus intended for use with an external battery
14.10.6 Vehicle battery adapters comply with UL 2089 N/A
14.11 Component power supplies and their optocouplers N/A
complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfill
the test requirements on the clause.
14.11 Optocouplers comply with UL 1577. Pass
14.11 Optocouplers bridging reinforced insulation comply Pass
with requirements for double protection as
specified in UL 1577
14.11 External clearances and creepage distances of Pass
optocouplers comply with 13.1. The alternative to
use the test of 13.6 has been deleted.
14.12 UL 1449 replaces reference to IEC 61051-2 and Pass
UL 94 replaces reference to IEC 60707. All
references to IEC 60151 have been deleted.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 48 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

15.1.1 Attachment plug has a current rating no less than Pass


125% of the current drawn under normal operating
conditions and a voltage rating appropriate for
rated voltage of the apparatus
15.1.1 Attachment plug provided with apparatus which Pass
may be used on more than one supply voltage by
means of a voltage selector is rated for the voltage
to which the apparatus is intended to be connected
when it is shipped from the factory
15.1.1 Attachment plug cap is polarized when the N/A
apparatus is provided with a manually operated,
line connected, single-pole switch; Edison-base
lampholder; or a 15- or 20-ampere socket-outlet
15.1.1 The identified grounded circuit conductor (neutral) N/A
is connected to the screw shell of the lampholder
and/or wide blade of a socket outlet
15.1.1 A manually operated, mains connected, single-pole N/A
on-off switch shall not be connected to the neutral
conductor
15.1.1 References to IEC 60083, IEC 60320, IEC 60884 Pass
and IEC 60906 have been deleted
15.1.1 Conductors and internal wiring connecting mains N/A
socket-outlets comply with requirements for wire
size per clause 16.2, based on the marked rating of
the outlet but are not less than 18 AWG
15.1.2 Apparatus may employ "banana" plug connectors N/A
for connectors other than for connecting to mains
power
15.1.3.1 Audio amplifiers having an open-circuit audio N/A
output voltage not limited to 120 V that are
permanently connected to the mains.
15.1.3.1 Quick Connect Terminals N/A
15.1.3.1a Male tabs firmly mounted in place N/A
15.1.3.1b Mating female connectors provided with the N/A
apparatus
15.1.3.1c Strain Relief Test of Clause 16.5 N/A
15.1.3.1d Installation instructions provided for assembly of N/A
terminal to a conductor and strain relief
15.1.3.1e Terminals are appropriate for use with the size and N/A
type of wire specified
15.1.3.2 Audio amplifiers having an audio output not limited N/A
to 120 V that are connected to the mains by a

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 49 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

flexible cord
15.2 The earthing conductor in a supply cord or in an N/A
interconnecting cable has an equivalent or larger
cross-sectional area than the current-carrying
conductors in the supply cord or cable
15.2 As an option, the earthing conductor may instead N/A
have green colored insulation
15.3.5 For rated currents over 13 amperes, terminals for N/A
external flexible cords comply with Article 310 of
the National Electrical Code, ANSI/NFPA 70.
Reference to IEC 60950, Table 3D has been
deleted.
15.3.5 Table 15 - Terminals for flexible cords are sized to N/A
accept the AWG wire size specified in the Table.
Reference to cross section area in mm² has been
deleted.
15.3.5 Table 15 - Note added for apparatus rated up to N/A
and including 2 amperes.
15.4 Component power supply adaptors complying with N/A
the construction and test requirements of UL 1310,
UL 1950 Third Edition, UL 60950, or UL 60950-1
fulfill the test requirements on the clause
16.1 Reference in the first paragraph to "sheathed" Pass
flexible cords is deleted
16.1 Mains supply flexible cords comply with UL 817, Pass
are marked VW-1, and have an ampacity not less
than the current drawn by the apparatus.
References to IEC 60173, 60227 and 60245 have
been deleted.
16.1 As an option, the protective earthing terminal N/A
conductor in the supply cord may instead be green
in color
16.1 Table 17A - Types of cords and cord lengths for Pass
various types of apparatus
16.2 An integral earthing conductor in the power supply N/A
cord is at least the same size as the other cord
conductors
16.2 Article 400 of the National Electrical Code replaces Pass
reference to IEC 60950, Table 3B
16.2 Table 18 - Wire size of external flexible cords Pass
16.3c Flexible cords used as interconnecting cable N/A
comprised of conductors in which the open-circuit
voltage > 35 V(peak) ac or dc; or carrying current >

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 50 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

0.2 amperes are marked VW-1


16.3c Flexible cords not complying with 16.1, used as N/A
connection between the apparatus and other
apparatus used in combination with it, are marked
VW-1
16.5 When polymeric materials are involved, testing is to N/A
be conducted before and after the sub-clause
12.1.5 stress relief test
17.8 Relevant fixing means and assembly instructions N/A
are required when detachable legs, stands,
casters, and brackets are supplied by the
manufacturer
17.8 Expanded to include all cart/stand parts supplied N/A
by the manufacturer, such as casters and brackets.
Suitable assembly instructions are required.
17.10 Termination of aluminum conductors, insulated or N/A
uninsulated, used as internal wiring
17.11 User installed accessories N/A
17.11.1 Accessories installed by skilled persons N/A
18 Non intrinsically protected picture tubes comply N/A
with 18.1, 18.2.2, and 18.3. Intrinsically protected
picture tubes with a face dimension exceeding 7.5
cm comply with UL 61965.
18 A bulb of a picture tube having a face diameter of N/A
7.5 cm or more is mounted in an enclosure. The
enclosure has no opening that exceeds 130 mm²
unless the minor dimension of the opening is 10
mm or less.
18.1 All tubes with a face dimension exceeding 16 cm N/A
are mounted such that the enclosure of the
apparatus protects the tube against the effects of
implosion
18.2 Deleted N/A
18.2.1 Deleted N/A
18.2.3 Deleted N/A
19 The tests in 19.1, 19.2 and 19.3 do not cause the Pass
apparatus to overturn.
19 During the test in 19.2.1, the apparatus did not N/A
slide
19 The test of 19.3 is conducted on 1) Apparatus with N/A
direct view CRT with 48 cm diagonal minimum, 2)
Apparatus, other than a speaker, with a mass

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 51 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

greater than 47 kg, and 3) Apparatus, other than a


speaker, with a mass or 25 kg or greater and a
height of 1 meter or more
19 When polymeric materials are involved, testing is to N/A
be conducted before and after the sub-clause
12.1.5 stress relief test
19.1 References to an apparatus in combination with a N/A
supplied cart or recommended stand are deleted
19.2 References to an apparatus in combination with a N/A
supplied cart or recommended stand are deleted
19.2.1 Slide test N/A
19.3 Existing test deleted and replaced with horizontal N/A
force test. Table 20A was added to specify values
for the horizontal force test.
19.5 Impact test compliance deletes the use of the IEC Pass
60068-2-75 spring operated hammer
19.6 Equipment that may be rack mounted have been N/A
included into the scope of this mounting means test
20.1a Deleted Pass
20.1b UL 94 replaces reference to IEC 60695-11-10 Pass
20.1b Parts such as protection TV lenses, loudspeaker N/A
parts, external accessories, and fibrous materials
less than 0.25 mm thick are considered to
contribute negligible fuel to a fire
20.1.2 Sleeving, extruded tubing and insulation on wiring Pass
are rated VW-1 under following conditions: a)
wiring located in a circuit that is considered a
potential ignition source, or b) wiring not located in
a circuit that is a potential ignition source but is in
contact with wiring located in a circuit that is a
potential ignition source.
20.1.2 Tape in contact with parts of circuits that are N/A
potential ignition sources is flame retardant
20.1.2c Deleted Pass
20.1.3 Printed wiring boards, on which the available power Pass
as the connection exceeds 15 W or the operating
voltage exceeds 50 V (peak) under normal
operating conditions, are minimum flammability
category V-1 or better.
20.1.3 Base material of printed wiring boards on which the Pass
available power at a connection exceeds 15 W
operating at a voltage exceeding 400 V (peak) a.c.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 52 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

or d.c. under normal operating conditions, and


base material of printed boards supporting spark
gaps which provide protection against
overvoltages, are minimum flammability category
V-0.
20.1.3 The exception for printed boards housed in Pass
enclosures has been deleted.
20.1.3 UL 94 replaces references to IEC 60707. The Pass
option to use Annex G is deleted.
20.1.4 Components and parts comply with the relevant Pass
flammability category according to UL 94 as
specified in table 21
20.1.4 Component power supplies complying with the N/A
construction and test requirements of UL 1310, UL
1950 Third Edition, UL 60950, or UL 60950-1 fulfill
the test requirements of the clause
20.1.4 Table 21 - "Flammability categories for Pass
components and parts" replaces existing Table,
"Distances from potential ignition sources and
consequential flammability categories."
20.2.1 Fire enclosure required for: 1) circuits and Pass
components where the available power exceeds 15
W, 2) inductors and windings conductively
connected to the mains, and 3) high-voltage
apparatus.
20.2.1 The fire enclosure complies with Table 22 - See Critical Component List. Pass
"Flammability categories for fire enclosures"
20.2.1 UL 94 or UL 746C replace references to IEC 60707 Pass
and Annex G.
20.2.2 Internal fire enclosures do not have openings that N/A
permit accessibility to components, wiring,
connections, or printed wiring board conductive
patterns where the available power exceeds 15 W
and to inductors and windings conductively
connected to the mains and shall comply with the
material requirements in Table 22
20.2.2 Compliance checked by inspection and Pass
measurement and using the articulated finger
probe (Figure 18).
20.2.3 Outer enclosures have a minimum flammability N/A
rating of HB, per UL 94, when an internal fire
enclosure is provided
A Apparatus intended for outdoor use, wet location N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 53 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

use or permanent outdoor location use has any of


the following attributes: a) provided with a means to
be transportable, b) has a mass less than 35 kg, c)
can be battery operated, or d) associated literature
states or implies such use
A An apparatus as described in a), b), or c) above N/A
that is marked as specified in 5.4.1 a) is not
intended for outdoor use or wet location use
A Apparatus permanently installed outdoors is N/A
considered to be for permanent outdoor use
A.5 Deleted N/A
A.5.1j Deleted N/A
A.5.4.1 Deleted N/A
A.9.1.1.1 The touch current test of 9.1.1.1 is to be repeated N/A
following the water spray test in A.11.1.1.
A.10 Deleted N/A
A.10.2 Deleted N/A
A.10.2.1 Deleted N/A
A.10.2.2 Deleted N/A
A.11.1.1 Apparatus subjected to the water spray test N/A
specified in UL 1598
A.16.1 Flexible cords are suitable for outdoor use N/A
A.20.2.1 Enclosures for an apparatus intended for N/A
permanent outdoor location comply with
requirements for Type 3 enclosures in UL 50
B Complies with Clause 4 of IEC 62151 with N/A
exception to 4.1.2, 4.1.3, 4.2.1.1, and 4.2.1.2.
B The requirements of 4.2.1.1 are replaced by the N/A
requirements of 2.3.1 of UL 60950 Third Edition or
UL 60950-1.
B After a single insulation fault, the voltages on TNV- N/A
0, TNV-1, and accessible parts are permitted to
exceed the limits in 9.1.1.1a) for a period of time
not exceeding 0.2 s. In addition, the limits of 11.1
were not exceeded.
B Apparatus intended to be connected to N/A
telecommunication networks and having ringing
voltages applied to the apparatus is subjected to
touch current limits in accordance with clause
5.1.8.1.1 of UL 60950 Third Edition, or 5.1.8.3 of
UL 60950-1.

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 54 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

B Telecommunication network that uses outside N/A


cable complies with the requirements for protection
against overvoltage from power line crosses
according to 6.4 of UL 60950 Third Edition, or UL
60950-1.
B Acoustic tests per 6.5 of UL 60950 Third Edition, or N/A
UL 60950-1 for apparatus containing an earphone.
B Apparatus provided with appropriate markings and N/A
instructions as described in Annex NAA of UL
60950 Third Edition, or UL 60950-1
D UL 101 replaced reference to IEC 60990 Pass
D Add touch current value in MIU where Pass
MIU = U2 x 2 (r.m.s. value)
G Deleted Pass
L Deleted Pass
Q Safety requirements for video apparatus for use in health care facilities N/A
Q.1.1.1 Signaling and nurse-call feature, when provided, N/A
complies with UL 1069
Q.4.2.3.1 Burnout test N/A
Q.5.2d Receptacle marking required to identify specific N/A
permitted accessory
Q.5.4.4 An apparatus shall be capable of being cleaned N/A
and disinfected in accordance with manufacturer's
instructions without increasing the risks of fire,
shock and injury.
Q.5.4.4 A sample of the apparatus shall be subjected to the N/A
touch current test described in Q.9.1.1.1
Q.5.4.5 Class I apparatus shall be marked, "When N/A
grounding of the accessible metal parts is required,
a separate grounding lead is to be used"
Q.5.4.5 Class II apparatus shall be marked, "Double N/A
Insulation - External Metal Grounded - Caution -
When servicing use only identical replacement
parts"
Q.5.4.6 Installation and operation instructions are provided N/A
Q.5.4.7 Unearthed (isolated) parts marking N/A
Q.5.4.8 Pendant control marking N/A
Q.7.1.1 Normal temperature test N/A
Q.8.18 Parts touched by patient N/A
Q.9.1.1.1 Touch current test N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 55 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

Q.9.1.8 Design of the apparatus is such that entry of spilled N/A


materials is prevented
Q.10.2.1 Cleaning test N/A
Q.10.2.2 Immersion test N/A
Q.10.3 Dielectric voltage-withstand test N/A
Q.12.1.3 Impact test N/A
Q.12.1.4 Drop test N/A
Q.14.3.4 Transformers connected in the primary circuit N/A
intended to supply power to low voltage pendant
controls comply with UL 60601-1
Q.14.6.1.1 Supply circuit ON/OFF switch controls all poles N/A
simultaneously
Q.14.6.3 On-off switch position marking N/A
Q.14.12 Hook or holder for pendant control support is N/A
provided and is located outside of the bed
Q.15.1.1 Class I apparatus is provided with a "Hospital N/A
Grade" grounding type attachment plug
Q.15.2.1 Class I apparatus and auxiliary equipment having N/A
isolated conductive surfaces have provision for the
earthing of such surfaces
Q.15.2.1 Class II apparatus and auxiliary equipment having N/A
isolated conductive surfaces have provision for the
earthing of such surfaces
Q.16.1 The flexible supply cord is Type SJ, SJO, SJT, N/A
SJTO, or the equivalent, having suitable voltage
rating and ampacity. The flexible supply cord is
suitable for the intended installation environment.
Q.16.1 The length of the flexible supply cord is not less N/A
than 1.5 m
Q.16.5 The pendant control cord is provided with strain N/A
relief at both ends of the cord
Q.17.8 The wheels and casters on an apparatus or on a N/A
cart intended for use with a specific apparatus have
a minimum diameter of 10 cm
Q.20.2.4 Pendant control enclosure N/A
R Safety requirements for undercabinet apparatus N/A
R.4.1.4 Mounting requirements for the temperature, N/A
elevated ambient, increased moisture and
mounting security tests

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 56 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

R.5.4.3 Operation and installation instructions marking, N/A


"CAUTION, To reduce the risk of fire, do not place
any heating or cooking apparatus beneath this unit"
R.10.2.1 Following the undercabinet increased moisture N/A
test, the apparatus complies with the touch current
test (9.1.1.1) and the dielectric strength test (10.3)
R.10.2.2 Undercabinet increased moisture test N/A
R.11.1.1 Following the undercabinet elevated ambient test, N/A
the apparatus complies with the requirements for
accessible parts (9.1.1.2) and the dielectric
strength test (10.3)
R.11.1.2 Apparatus mounting instructions for the N/A
undercabinet elevated ambient test
R.11.1.3 Undercabinet elevated ambient test N/A
R.12.1.5.1 Temperature stability test N/A
R.12.9 Undercabinet mounting stability test N/A
R.16.8 The apparatus is provided with means for flexible N/A
cord routing and cord storage such that excess
cord does not hang down
S Safety requirements for in-wall mounted apparatus N/A
S.5.4.4 Installation and mounting instructions are provided N/A
S.5.4.4.1 Marking for apparatus not investigated for in-wall N/A
mounting, worded, "Not Suitable for In-Wall
Mounting"
S.15.5 Permanent connection to a wiring system in N/A
accordance with the National Electrical Code,
NFPA 70
S.15.5.1 Enclosure intended for conduit entry has a N/A
minimum thickness of 1.35 mm (uncoated)
S.20.2.4 Unused openings are not provided for those N/A
portions of the enclosure located within the wall
cavity
S.20.2.4 Table S.14 - Flammability category for polymeric N/A
enclosures added
T Safety requirements for apparatus with projection lamps N/A
T.4.3.6 Additional considerations for fault conditions tests N/A
T.4.3.16 Fault tests N/A
T.4.3.16.1 Semiconductor component fault testing N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 57 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

T.5.4.4 Cautionary and warning markings N/A


T.5.4.5 Hot surface marking N/A
T.5.4.6 Lamp ultraviolet radiation N/A
T.5.4.7 Ultraviolet radiation under servicing conditions N/A
T.5.4.8 Interlocks N/A
T.5.4.9 Lamp servicing N/A
T.6.3 Ultraviolet radiation test N/A
T.7.1 Normal temperature test N/A
T.9.1.1 Electric shock test N/A
T.14.5.1.2 Overtemperature-protective devices N/A
T.18.1 Lamp rupture test N/A
T.20.2.1 Lamp compartment N/A
U Safety requirements for permanently connected apparatus N/A
U.21.1 Supply connections N/A
U.21.1.1 Permanently connected and cord connected N/A
apparatus
U.21.1.2 Sheet metal to which a wiring system is connected N/A
U.21.1.3 Terminal box or compartment N/A
U.21.1.4 Volume of a field wiring compartment complies with N/A
Table U.1
U.21.1.5 Pigtail leads N/A
U.21.1.6 Electrical components mounted on removable parts N/A
U.21.1.7 Resistance to turning of supply raceway N/A
U.21.2 Separation of circuits N/A
U.21.2.1 Separation of field installed conductors N/A
U.21.3 Wiring terminals N/A
U.21.3.1 Wiring terminal construction N/A
U.21.3.2 Rotation prevention of field wiring terminals N/A
U.21.3.3 Smallest conductor used at field wiring terminals N/A
U.21.3.4 Terminal plate used for wire binding screws N/A
U.21.3.5 Free length of lead inside outlet box or wiring N/A
compartment

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 58 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

U.21.3.6 Grounded circuit conductor (neutral) N/A


U.21.3.7 Minimum wire bending space complies with Table N/A
U.2
U.21.3.8 Field wiring terminal for apparatus grounding N/A
conductor is provided
U.21.3.9 Field wiring terminal for apparatus grounding N/A
conductor connector
U.21.3.10 Wire-binding screw or screw-type connector N/A
construction
U.21.3.11 Apparatus grounding conductor insulation color N/A
U.21.4 Spacings at field wiring terminals N/A
U.21.4.1 Spacings comply with Table U.3 N/A
U.21.5 Earth connections in permanently connected apparatus N/A
U.21.5.1 Marking of apparatus earthing terminal N/A
U.21.6 Supply wire temperature rating N/A
U.21.6.1 Marking for supply wiring having temperatures > N/A
60°C during temperature test
U.21.7 Different conductor materials N/A
U.21.7.1 Field wiring terminal marking for copper and/or N/A
aluminum wire
V Safety requirements for carts, stands, and similar apparatus for use with specific N/A
apparatus covered by this standard
V.5.1 Marking when cart/stand is packaged and N/A
marketed separately from intended apparatus
V.5.4 Marking when it is not feasible to include a specific N/A
apparatus model number
V.12.9 Injury to persons tests N/A
V.12.9.1 Apparatus, cart, or stand temperature stability N/A
V.12.9.2 Wheel or caster securement N/A
V.12.9.3 Cart or stand loading N/A
V.12.9.4 Cart or stand impact test N/A
V.12.9.5 Cart or stand handle strength test N/A
V.12.9.6 Mounting means test N/A
V.19 Mechanical stability N/A
V.19.1 10° tilt test N/A

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 59 of 59 Report Reference # E176413-A31-CB-3

IEC/EN 60065
SubClause Difference + Test Result - Remark Verdict

V.19.2 100 N downward force test N/A


V.19.3 Horizontal force test applied in accordance with N/A
Table 20A
W Construction details for a 0.02-ohm shunt for use in N/A
the peak inrush-current measurement described in
14.6.11.1
X Manufacturing and production-line tests Pass
Y Standards for components Pass

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 1 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Enclosures

Type Supplement Id Description


Marking Plate 13-07 Marking Plate
Photographs 3-02 PS 3-2-1 (Overall)
Photographs 3-03 PS 3-2-1 (Rear)
Photographs 3-04 PS 3-2-1 (Internal View - Linear Power Supply)
Photographs 3-05 PS 3-2-1 (Internal view I/O board)
Photographs 3-06 CineMate Series II (I/O Board)
Photographs 3-07 CineMate Series II (Power Supply)
Photographs 3-08 CineMate Series II (Internal view I/O board)
Photographs 3-09 CineMate Series II (Internal View)
Diagrams 4-01 Premium Remote
Diagrams 4-02 Basic Remote
Schematics + PWB 5-01 CineMate Series II
Schematics + PWB 5-02 PS 3-2-1
Manuals 6-01 Manual
Miscellaneous 7-01 Letter of Assurance
Miscellaneous 7-02 Lithium Batteries
Miscellaneous 7-03 Lithium Batteries
Miscellaneous 7-04 Lithium Batteries
Miscellaneous 7-05 Lithium Batteries
Licenses 8-01 X-Cap - Arcotronics R.46#
Licenses 8-02 Y1 Cap - Murata KX
Licenses 8-03 Optocoupler - Vishay CNY17F
Licenses 8-04 Thermal Fuse - Uchihashi Type X23
Licenses 8-05 Mains Switch - Marquardt 1551
Licenses 8-06 Voltage Selector Switch - Marquart 4021
Licenses 8-07 Thermal Fuse - Anzen
Licenses 8-08 Remote - 285104
Licenses 8-09 Remote - 318809
Licenses 8-10 TUV Certificates
Licenses 8-11 T701 CB Test Certificate

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 2 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 3 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 4 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 5 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 6 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 7 of 169 Report Reference # E176413-A31-CB-3
Enclosures

MarkingPlate ID 13-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 8 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 9 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 10 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 11 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 12 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 13 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 14 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 15 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Photographs ID 3-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 16 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Diagrams ID 4-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 17 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Diagrams ID 4-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 18 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Diagrams ID 4-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 19 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Diagrams ID 4-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 20 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 21 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 22 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 23 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 24 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 25 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 26 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 27 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 28 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 29 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 30 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 31 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 32 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 33 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Schematics ID 5-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 34 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 35 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 36 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 37 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 38 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 39 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 40 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 41 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 42 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 43 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 44 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 45 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 46 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 47 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 48 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 49 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 50 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 51 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 52 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 53 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 54 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 55 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 56 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 57 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 58 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 59 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 60 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 61 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 62 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 63 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 64 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Manuals ID 6-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 65 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 66 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 67 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 68 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 69 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 70 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 71 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 72 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 73 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 74 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 75 of 169 Report Reference # E176413-A31-CB-3
Enclosures

Misc ID 7-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 76 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 77 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 78 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-01

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 79 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 80 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 81 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 82 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 83 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 84 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 85 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 86 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 87 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 88 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 89 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 90 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 91 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 92 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 93 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 94 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 95 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 96 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 97 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 98 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 99 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 100 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 101 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 102 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 103 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 104 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 105 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 106 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 107 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 108 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 109 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 110 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 111 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 112 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-02

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 113 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 114 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 115 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 116 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 117 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 118 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 119 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 120 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 121 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-03

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 122 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 123 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 124 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-04

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 125 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-05

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 126 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 127 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 128 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 129 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 130 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 131 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 132 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-06

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 133 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 134 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 135 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-07

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 136 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 137 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 138 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 139 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 140 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 141 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 142 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 143 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 144 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 145 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 146 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 147 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 148 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 149 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-08

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 150 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 151 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 152 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 153 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 154 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 155 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 156 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 157 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 158 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 159 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 160 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 161 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 162 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 163 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-09

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 164 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-10

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 165 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-10

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 166 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-10

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 167 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-10

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 168 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-10

Underwriters Laboratories Inc.


Issue Date: 2010-09-21 Page 169 of 169 Report Reference # E176413-A31-CB-3
Enclosures

License ID 8-11

Underwriters Laboratories Inc.

Вам также может понравиться