Please enter the Full load speed for the Excavator Being Tested: 1800 RPM
Specs
Pressure
(psi) High Low
1420 65 50
2275 56 43
2845 52 39 P-Q Curve for
3700 46 31 Right Pump Excavator
70
4250 42 28
60
50
Flow (GPM) Hig
UP PUMP Test Data 40 h
Pressure Flow Corrected Flow Lo
(psi) (GPM) RPM (GPM) 30 w
0 #DIV/0!
1420 69.07 1980 62.79 20
2275 60.08 1979 54.65
2845 52.48 1978 47.76 10
3700 44.29 1976 40.35
4250 40.08 1978 36.47 0
0 #DIV/0! 0 1420 2275 2845 3700 4250 0
Pressure (psi)
DOWN Pump Test Data
P-Q Curve for
Pressure Flow Corrected Flow Left Pump Excavator
(psi) (GPM) RPM (GPM) 80
0 #DIV/0!
1420 73.55 1979 66.90 70
2275 63.62 1978 57.89
60
2845 56.89 1978 51.77
3700 49.4 1976 45.00 50 High
Flow (GPM)
4250 44.5 1974 40.58 Low
0 #DIV/0! 40 Test
30
20
10
0
0 1420 2275 2845 3700 4250 0
Pressure (psi)
P-Q Plots
Fill In The Yellow Cells
Disregard all data that is "blacked" out
Note: This is set up for a 330C SN: CYA00498 - Change the values in the "specs" chart below for other machines
Note: This is set up for a 330C SN: CYA00498 - Change the values in 1800 RPM
Specs
Pressure
(psi) High Low
1420 65 50
2275 56 43
2845 52 39 P-Q Curve for
3700 46 31 Right Pump Excavator
70
4250 42 28
60
50
Flow (GPM) Hig
UP PUMP Test Data 40 h
Pressure Flow Corrected Flow Lo
(psi) (GPM) RPM (GPM) 30 w
0 #DIV/0!
1420 69.37 1978 63.13 20
2275 59.54 1978 54.18
2845 52.2 1979 47.48 10
3700 44.36 1970 40.53
4250 39.65 1976 36.12 0
0 #DIV/0! 0 1420 2275 2845 3700 4250 0
Pressure (psi)
DOWN Pump Test Data
P-Q Curve for
Pressure Flow Corrected Flow Left Pump Excavator
(psi) (GPM) RPM (GPM) 70
0 #DIV/0!
1420 67.27 1977 61.25 60
2275 57.29 1977 52.16
2845 51.6 1977 46.98 50
3700 44.28 1976 40.34 High
Flow (GPM)
4250 39.4 1975 35.91 40 Low
0 #DIV/0! Test
30
20
10
0
0 1420 2275 2845 3700 4250 0
Pressure (psi)
Hydraulic Horsepower Hydraulic Horsepower
Fill In The Yellow Cells Fill In The Yellow Cells
*Note Flowmeter Pressure Used to Calculate HHP @ Boom Foot
Ambient Air Calculated Left Pump Ambient Air Calculated Valve Efficiency
PSI Flow (GPM) R/pump (psi) L/pump (psi) Temp (Fahrenheit) Cr HP PSI Flow (GPM) Flowmeter (psi) Temp (Fahrenheit) Cr HP
1000 60 1.008 1000 60 1.008
1700 0 1700 0 #DIV/0!
2000 0 2000 0 #DIV/0!
2500 0 2500 0 #DIV/0!
3000 0 3000 0 #DIV/0!
3500 0 3500 0 #DIV/0!
4000 0 4000 0 #DIV/0!
4500 0 4500 0
4800 0 4800 0
Corrected HHP
Corrected HHP
* Note: The correct ambient air temperature in Fahrenheit is VERY Important. * Note: The correct ambient air temperature in Fahrenheit is VERY Important.
This is used to calculate the correction factors for Fuel Temp and Inlet Air Temp. This is used to calculate the correction factors for Fuel Temp and Inlet Air Temp.
The API correction factor (Cr) of 1.017 is used when API # isn't available because it is the median value.
If the exact fuel correction factor is available, it should be used in place of this.