PLANT SUPPLY REQUIREMENTS

DSE332 MINIMUM SUPPLY VOLTAGE


AUTO TRANSFER SWITCH CONTROL 8V continuous

CRANKING DROPOUTS
Able to survive 0V for 50ms providing the
supply was at least 10V before the dropout
and recovers to 5V afterwards.

MAX OPERATING SUPPLY VOLTAGE


NEW RELEASE 35V continuous

MAX OPERATING SUPPLY CURRENT


300mA at 12V, 170mA at 24V

MAX STANDBY CURRENT


100mA at 12V, 70mA at 24V

GENERATOR AND MAINS (UTILITY)


VOLTAGE INPUT
DSE160
SELF-SEEKING POWER SUPPLY MEASUREMENT METHOD
True RMS up to 11th harmonic

AC SYSTEMS SUPPORTED
2 Phase, 3 Wire L1-L2
2 Phase, 3 Wire L1-L3
3 Phase, 3 Wire
3 Phase, 4 Wire
3 Phase, 4 Wire Delta
Single Phase, 2 Wire

PHASE TO NEUTRAL VOLTAGE RANGE


15V to 333V AC absolute maximum
110V to 277V nominal

PHASE TO PHASE VOLTAGE RANGE


25V to 576V AC

COMMON MODE OFFSET


100V AC from neutral to plant ground

The DSE332 is an Automatic The module includes configurable BENEFITS RESOLUTION


1V AC phase to neutral
Transfer Switch Controller for digital inputs and outputs and is • Provides automatic mains (utility) 2V AC phase to phase
single genset applications. programmable by PC using the monitoring and controls change ACCURACY
The module will monitor the voltage user-friendly DSE Configuration over to generator supply ±1% of full scale phase to neutral
(Excluding VT error)
and frequency of the incoming AC Suite Software. Limited • Real-time clock provides accurate ±2% of full scale phase to phase
mains (utility) supply (supports programming is also available event information (Excluding VT error)
many topologies) and in the event of via the module’s front panel. • User-friendly set-up and button VT SCALING
a failure will issue a start command layout Support for VT’s with primary voltage up to 40kV
to the generator control system. FEATURES • Will work with external FREQUENCY
• Supports many topologies synchroniser for seamless return 3.5Hz to 75Hz
Once the generator is available • Automatic switch over to generator to mains (utility) CHECK SYNC
and producing an output within • Check sync feature 1Hz 25o

limits, the DSE332 will control the • Real-time clock OPERATION PHASE LAG MEASUREMENT
With respect to mains voltage on L1 only
transfer devices and switch the • Ten configurable inputs System information is available instantly
load from the mains (utility) to the • Five configurable outputs on the LCD display by using the scroll PHASE LAG RESOLUTION
3.6 degrees at 50Hz
generating set. • Event log showing most recent 10 push buttons next to the screen.
events
Once the mains (utility) supply • Configurable timers SELF-SEEKING POWER SUPPLY
returns to within limits, the module • Automatic shutdown or warning A self-seeking power supply is
will command a return to the mains when fault conditions are detected available for this product when a DC
(utility) supply and shut down the • Protected Solid State Outputs supply is not available. This can be
generator after a cooling run. (PSS) ordered separately or as a kit.
Various timing sequences are • PC programming DIMENSIONS
available to prevent nuisance • Front panel programming Features include:
starting on minor supply breaks. • LED indicators • 12V & 24V options OVERALL
• LCD text display • LED indication 216mm x 158mm x 42mm
8.5” x 6.2” x 1.6”
The DSE332 includes a clear • External mains (utility) or genset • Can be used as AC/DC power
back-lit LCD 4-line text display, failure inputs supply PANEL CUT-OUT
showing system status and • Auto start inhibit • 1A DC output 182mm x 137mm
7.2” x 5.4”
warnings. Red and Green LEDs • Load inhibit Please see product information on the MAXIMUM PANEL THICKNESS
also indicate operation status. • Manual restore to mains (utility) DSE160 Self-Seeking Power Supply. 8mm (0.3”)
DEEP SEA ELECTRONICS PLC TELEPHONE EMAIL ®
Highfield House +44 (0)1723 890099 sales@deepseaplc.com
Hunmanby Industrial Estate
Hunmanby, North Yorkshire FACSIMILE WEBSITE
YO14 0PH England +44 (0)1723 893303 www.deepseaplc.com

Registered in England & Wales No.01319649 VAT No.316923457

DEEP SEA ELECTRONICS INC TELEPHONE EMAIL


3230 Williams Avenue +1 (815) 316 8706 sales@deepseausa.com
Rockford
IL 61101-2668 USA FACSIMILE WEBSITE
+1 (815) 316 8708 www.deepseausa.com
SPECIFICATION

LOAD CURRENT INPUT

DSE332 LOAD
PHASES MONITORED
1 to 3 (depending upon topology setting)

CT COMMON MUST BE
MEASUREMENT METHOD
P2
CONNECTED TO THE SAME GROUND True RMS up to 11th harmonic
AS BATTERY NEGATIVE
S2
CT’s 5 AMP NOMINAL CT SECONDARY RATING
SECONDARY
METERING CLASS 5A
S1
MAXIMUM CONTINUOUS CURRENT
P1
5A
OVERLOAD MEASUREMENT
15A for 100mS
BURDEN
L1 L1
0.5VA
COMMON MODE OFFSET
L2 L2 ±2V peak - plant ground to CT common terminal
RESOLUTION
FROM L3 L3
FROM
25mA
GENERATOR MAINS
(UTILITY) ACCURACY
N N
±1% of Nominal (5A) excluding CT error

2 DEDICATED DIGITAL OUTPUTS – A & B


GENERATOR AND MAINS (UTILITY)
2 AMP 2 AMP
FUSES FUSES
ELECTRICAL AND
MECHANICAL INTERLOCK
CURRENT RATING
8A AC resistive

VOLTAGE RATING
250V AC
G M
2 CONFIGURABLE FET OUTPUTS C & D
CURRENT RATING
2A
31 32 33 34 23 24 25 26 21 22 20 19 27 28 29 30 7
VOLTAGE RATING
CT1 CT2 CT3 COM U
L1
V
L2
W
L3
N R
L1
S
L2
T
L3
N
5V to 35V
LOAD CURRENT GENERATOR MAINS
GEN VOLTS MAINS VOLTS
LOADING RELAY LOADING RELAY
OUTPUT B OUTPUT A PROTECTIONS
USB
Over Current, Over Temperature, Built in Load
MODULE 332 dump feature
GEN AVAILABLE

PROGRAMMING PORT
2 FET OUTPUTS C&D
PLANT +VE
10 -VE INPUTS 1 CONFIGURABLE RELAY OUTPUT E
INPUT K

BATTERY
OUTPUT E
-VE

+VE

A B C D E F G H I J
CURRENT RATING
1 2 3 4 5 6 18 8 9 10 11 12 13 14 15 16 17 2A DC resistive
USER CONFIGURABLE +VE OUTPUT C

USER CONFIGURABLE +VE OUTPUT D

START & RUN GENERATOR

VOLTAGE RATING
35V DC resistive (UL rating 30V)
USER CONFIGURABLE -VE INPUT G
USER CONFIGURABLE -VE INPUT A
DEDICATED +VE INPUT K

ENVIRONMENTAL TESTING STANDARDS


USER CONFIGURABLE -VE INPUT E

USER CONFIGURABLE -VE INPUT H


USER CONFIGURABLE -VE INPUT B

ELECTRO MAGNETIC COMPATIBILITY


BS EN 61000-6-2
EMC Generic Immunity Standard for the
USER CONFIGURABLE -VE INPUT F
USER CONFIGURABLE -VE INPUT C

Industrial Environment
USER CONFIGURABLE -VE INPUT I

BS EN 61000-6-4
USER CONFIGURABLE -VE INPUT J

EMC Generic Emission Standard for the


MIN 2 AMP MAX 20 AMP
ANTI-SURGE FUSE

Industrial Environment
USER CONFIGURABLE -VE INPUT D

ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
12 OR 24V BATTERY

TEMPERATURE
BS EN 60068-2-1 o
Ab/Ae Cold Test -30 C
BS EN 60068-2-2 o
Bb/Be Dry Heat +70 C
VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three major axes
5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn
BATTERY NEGATIVE MUST BE GROUNDED
HUMIDITY
TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm ) BS EN 60068-2-30
FIELD WIRING Db Damp Heat Cyclic 20/55oC @ 95% RH 48Hours
ISSUE 3
BS EN 60068-2-78
TIGHTENING TORQUE = 0.8Nm (7lb-in) Cab Damp Heat Static 40oC @ 93% RH 48 Hours
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes 15gn
RELATED MATERIALS in 11mS
TITLE PART NO’S
Operators Manual 057-097
Configuration Suite Manual 057-106
DSE160 Self-Seeking Power Supply Data Sheet 055-076

DEEP SEA ELECTRONICS maintains a policy of continuous development and reserves the right to
change the details shown on this data sheet without prior notice. The contents are intended for guidance only.

This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre
from both pre and post-consumer sources, together with 45% virgin ECF fibre.
055-075/04/10 (3)

Вам также может понравиться